Home/Catalog/NextUPSSystems

NextUPSSystems

The MIB module to describe UPS, Inverter, Salor Power
Main OID:
nextUPSSystems.1.3.6.1.4.1.21111
676
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

676 total
Object Name
nextUPSSystemsThe MIB module to describe UPS, Inverter, Salor Power
MODULE-IDENTITY
.1.3.6.1.4.1.21111
products
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1
ups
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.1
upsIdent
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.1.1
upsIdManufacturerThe name of the UPS manufacturer.ro
DisplayString
.1.3.6.1.4.1.21111.1.1.1.1
upsIdProtocolThe UPS Protocol id.ro
Enumeration
.1.3.6.1.4.1.21111.1.1.1.2
upsIdModelNameThe UPS Model designation.ro
DisplayString
.1.3.6.1.4.1.21111.1.1.1.3
upsIdSerialNumberThe UPS serial no.ro
DisplayString
.1.3.6.1.4.1.21111.1.1.1.4
upsIdNameA string identifying the UPS. This object should be set by the administrator.rw
DisplayString
.1.3.6.1.4.1.21111.1.1.1.5
upsIdFWVersionMain CPU firmware version.ro
DisplayString
.1.3.6.1.4.1.21111.1.1.1.6
upsIdUPSTypeUPS type.ro
Enumeration
.1.3.6.1.4.1.21111.1.1.1.7
upsRating
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.1.2
upsRatinVoltageThe rating input voltage of UPSro
NonNegativeInteger UNITS "0.1 Volt DC"
.1.3.6.1.4.1.21111.1.1.2.1
upsRatoutVoltageThe rating output voltage of UPSro
NonNegativeInteger UNITS "0.1 Volt DC"
.1.3.6.1.4.1.21111.1.1.2.2
upsRatoutFrequencyThe rating output frequency of UPSro
NonNegativeInteger UNITS "0.1 HZ"
.1.3.6.1.4.1.21111.1.1.2.3
upsRatoutCurrentThe rating output current of UPSro
NonNegativeInteger UNITS "0.1 Amp DC"
.1.3.6.1.4.1.21111.1.1.2.4
upsRatoutApparentPowerThe rating output apparent power of UPSro
NonNegativeInteger UNITS "0.1 VA"
.1.3.6.1.4.1.21111.1.1.2.5
upsRatoutTruePowerThe rating output true power of UPSro
NonNegativeInteger UNITS "0.1 Wt"
.1.3.6.1.4.1.21111.1.1.2.6
upsRatBatVoltageThe rating battery voltage of UPSro
NonNegativeInteger UNITS "0.1 vol"
.1.3.6.1.4.1.21111.1.1.2.7
upsBattery
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.1.3
upsBatStatusThe indication of the status in the UPS system's batteries.ro
Enumeration
.1.3.6.1.4.1.21111.1.1.3.1
upsBatSecondsOnBatteryIf the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. -1 shall be returned if the unit is not on battery power.ro
INTEGER UNITS "seconds"
.1.3.6.1.4.1.21111.1.1.3.2
upsBatEstMinutesRemainingAn estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.ro
INTEGER
.1.3.6.1.4.1.21111.1.1.3.3
upsBatEstChargeRemainingAn estimate of the battery charge remaining expressed as a percent of full charge.ro
INTEGER
.1.3.6.1.4.1.21111.1.1.3.4
upsBatPBatVoltageThe magnitude of the present Positive battery voltage.ro
NonNegativeInteger UNITS "0.1 Volt DC"
.1.3.6.1.4.1.21111.1.1.3.5
upsBatNBatVoltageThe magnitude of the present negative battery voltage.ro
NonNegativeInteger UNITS "0.1 Volt DC"
.1.3.6.1.4.1.21111.1.1.3.6
upsBatPBatCurrentThe positive battery present current.ro
INTEGER UNITS "0.1 Amp DC"
.1.3.6.1.4.1.21111.1.1.3.7
upsBatNBatCurrentThe present negative battery current.ro
INTEGER UNITS "0.1 Amp DC"
.1.3.6.1.4.1.21111.1.1.3.8
upsBatPBatChargCurrentThe Positive battery charging current.ro
INTEGER UNITS "0.1 Amp DC"
.1.3.6.1.4.1.21111.1.1.3.9
upsBatNBatchargCurrentThe present negative battery charging current.ro
INTEGER UNITS "0.1 Amp DC"
.1.3.6.1.4.1.21111.1.1.3.10
upsBatPBatDischargCurrentThe present positive battery discharging current.ro
INTEGER UNITS "0.1 Amp DC"
.1.3.6.1.4.1.21111.1.1.3.11
upsBatNBatDischargCurrentThe present negative battery discharging current.ro
INTEGER UNITS "0.1 Amp DC"
.1.3.6.1.4.1.21111.1.1.3.12
upsBatTemperatureThe ambient temperature at or near the UPS Battery casing.ro
INTEGER UNITS "degrees 0.1 Centigrade"
.1.3.6.1.4.1.21111.1.1.3.13
upsBatNumberInSeriesThe number of battery in series.ro
PositiveInteger (UPS-MIB)
.1.3.6.1.4.1.21111.1.1.3.14
upsBatNumberInParallelThe number of battery in Parallel.ro
PositiveInteger (UPS-MIB)
.1.3.6.1.4.1.21111.1.1.3.15
upsBatPBatDischargCurrent2The present positive battery pipe2 discharging current.ro
INTEGER UNITS "0.1 Amp DC"
.1.3.6.1.4.1.21111.1.1.3.16
upsInput
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.1.4
upsInLineBadsA count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance.ro
NonNegativeInteger (UPS-MIB)
.1.3.6.1.4.1.21111.1.1.4.1
upsInTtlApparentPowerTotal input apparent power .ro
NonNegativeInteger UNITS "0.1VA"
.1.3.6.1.4.1.21111.1.1.4.2
upsInTtlTruePowerTotal input active(true) power .ro
NonNegativeInteger UNITS "0.1WT"
.1.3.6.1.4.1.21111.1.1.4.3
upsInNumLinesThe number of input lines utilized in this device. This variable indicates the number of rows in the input table.ro
NonNegativeInteger (UPS-MIB)
.1.3.6.1.4.1.21111.1.1.4.4
upsInTableA list of input table entries. The number of entries is given by the value of upsInputNumLines.
SEQUENCE OF UpsInEntry
.1.3.6.1.4.1.21111.1.1.4.5
upsInEntryAn entry containing information applicable to a particular input line.
UpsInEntry
.1.3.6.1.4.1.21111.1.1.4.5.1
upsInLineIndexThe number of output linesro
INTEGER
.1.3.6.1.4.1.21111.1.1.4.5.1.1
upsInFrequencyThe present input frequency.ro
NonNegativeInteger UNITS "0.1 Hertz"
.1.3.6.1.4.1.21111.1.1.4.5.1.2
upsInVoltageThe input utility line voltage .ro
INTEGER UNITS "0.1 Volts"
.1.3.6.1.4.1.21111.1.1.4.5.1.3
upsInCurrentThe magnitude of the present input currentro
INTEGER UNITS "0.1Amp"
.1.3.6.1.4.1.21111.1.1.4.5.1.4
upsInApparentPowerThe magnitude of the present input Apparent power.ro
NonNegativeInteger UNITS "0.1VA"
.1.3.6.1.4.1.21111.1.1.4.5.1.5
upsInTruePowerThe magnitude of the present input true power.ro
NonNegativeInteger UNITS "0.1Watts"
.1.3.6.1.4.1.21111.1.1.4.5.1.6
upsInPowerFactorInput true power/apparent power factorro
NonNegativeInteger UNITS "0.01"
.1.3.6.1.4.1.21111.1.1.4.5.1.7
upsInLineVoltageThe input utility line voltage . if upsInLineIndex =1, upsInLineVoltage = Line voltage of RS phase; if upsInLineIndex =2, upsInLineVoltage = Line voltage of ST phase; if upsInLineIndex =3, upsInLineVoltage = Line voltage of TR phase.ro
INTEGER UNITS "0.1 Volts"
.1.3.6.1.4.1.21111.1.1.4.5.1.8
upsInTtlVoltageThe input utility line tatol voltage .ro
INTEGER UNITS "0.1 Volts"
.1.3.6.1.4.1.21111.1.1.4.6
upsInTtlCurrentThe input utility line tatol current.ro
INTEGER UNITS "0.1 A"
.1.3.6.1.4.1.21111.1.1.4.7
upsOutput
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.1.5
upsOutSourceThe present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.==UPS standby modero
Enumeration
.1.3.6.1.4.1.21111.1.1.5.1
upsOutTtlApparentPowerTotal output apparent power .ro
NonNegativeInteger UNITS "0.1VA"
.1.3.6.1.4.1.21111.1.1.5.3
upsOutTtlTruePowerTotal output active(true) power .ro
NonNegativeInteger UNITS "0.1Watts"
.1.3.6.1.4.1.21111.1.1.5.4
upsOutTtlPercentLoadThe percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.ro
INTEGER
.1.3.6.1.4.1.21111.1.1.5.5
upsOutNumLinesThe number of output lines utilized in this device. This variable indicates the number of rows in the output table.ro
INTEGER
.1.3.6.1.4.1.21111.1.1.5.6
upsOutTableA list of output table entries. The number of entries is given by the value of upsOutputNumLines.
SEQUENCE OF UpsOutEntry
.1.3.6.1.4.1.21111.1.1.5.7
upsOutEntryAn entry containing information applicable to a particular output line.
UpsOutEntry
.1.3.6.1.4.1.21111.1.1.5.7.1
upsOutLineIndexThe output line identifier.ro
INTEGER
.1.3.6.1.4.1.21111.1.1.5.7.1.1
upsOutVoltageThe output voltage of the UPS system.ro
INTEGER UNITS "0.1 Volts"
.1.3.6.1.4.1.21111.1.1.5.7.1.2
upsOutCurrentThe output current of the UPS systemro
INTEGER UNITS "0.1 Amp"
.1.3.6.1.4.1.21111.1.1.5.7.1.3
upsOutApparentPowerThe present output apparent power.ro
NonNegativeInteger UNITS "0.1VA"
.1.3.6.1.4.1.21111.1.1.5.7.1.4
upsOutTruePowerThe present output true power.ro
NonNegativeInteger UNITS "0.1Watts"
.1.3.6.1.4.1.21111.1.1.5.7.1.5
upsOutPowerFactorOutput true power/apparent power factorro
NonNegativeInteger UNITS "0.01"
.1.3.6.1.4.1.21111.1.1.5.7.1.6
upsOutPercentLoadThe percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.ro
INTEGER
.1.3.6.1.4.1.21111.1.1.5.7.1.7
upsOutLineVoltageThe output line voltage of the UPS system. if upsOutLineIndex =1, upsOutLineVoltage = Line voltage of RS phase; if upsOutLineIndex =2, upsOutLineVoltage = Line voltage of ST phase; if upsOutLineIndex =3, upsOutLineVoltage = Line voltage of TR phase.ro
INTEGER UNITS "0.1 Volts"
.1.3.6.1.4.1.21111.1.1.5.7.1.8
upsOutFrequencyThe present output frequency.ro
NonNegativeInteger UNITS "0.1Hertz"
.1.3.6.1.4.1.21111.1.1.5.7.1.9
upsOutTtlVoltageTotal output voltage .ro
INTEGER UNITS "0.1vot"
.1.3.6.1.4.1.21111.1.1.5.8
upsOutTtlCurrentTotal output current.ro
INTEGER UNITS "0.1A"
.1.3.6.1.4.1.21111.1.1.5.9
upsOutStatusFor HVDC device. char status[4]; status[0]status[1]:00, no output1; 01, line output1; 02, bat output1 status[2]status[3]:00, no output2; 01, line output2; 02, bat output2ro
DisplayString
.1.3.6.1.4.1.21111.1.1.5.10
upsOutSource2For HVDC(protocol:P12) machine. The present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.==UPS standby modero
Enumeration
.1.3.6.1.4.1.21111.1.1.5.11
upsBypass
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.1.6
upsByFrequencyThe present bypass frequency.ro
INTEGER UNITS "0.1 Hertz"
.1.3.6.1.4.1.21111.1.1.6.1
upsByNumLinesThe number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table.ro
INTEGER
.1.3.6.1.4.1.21111.1.1.6.2
upsByTableA list of bypass table entries. The number of entries is given by the value of upsBypassNumLines.
SEQUENCE OF UpsByEntry
.1.3.6.1.4.1.21111.1.1.6.3
upsByEntryAn entry containing information applicable to a particular bypass input.
UpsByEntry
.1.3.6.1.4.1.21111.1.1.6.3.1
upsByLineIndexThe bypass line identifier.ro
INTEGER
.1.3.6.1.4.1.21111.1.1.6.3.1.1
upsByVoltageThe present bypass voltage.ro
INTEGER UNITS "0.1 Volts"
.1.3.6.1.4.1.21111.1.1.6.3.1.2
upsByCurrentThe present bypass current.ro
INTEGER UNITS "0.1 RMS Amp"
.1.3.6.1.4.1.21111.1.1.6.3.1.3
upsByPowerThe present true power conveyed by the bypass.ro
NonNegativeInteger UNITS "0.1Watts"
.1.3.6.1.4.1.21111.1.1.6.3.1.4
upsByLineVoltageThe present bypass line voltage. if upsByLineIndex=1,upsByLineVoltage=Line voltage of RS phase; if upsByLineIndex=2,upsByLineVoltage=Line voltage of ST phase; if upsByLineIndex=3,upsByLineVoltage=Line voltage of TR phase.ro
INTEGER UNITS "0.1 Volts"
.1.3.6.1.4.1.21111.1.1.6.3.1.5
upsTest
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.1.7
upsTstBatteryTestThis object specify the battery test type and initiate battery test. If battTestWithTime selected, the test time is refer to upsTestBatteryTestTime.rw
Enumeration
.1.3.6.1.4.1.21111.1.1.7.1
upsTstBatteryTestResultThe results of the current or last UPS diagnostics test performed. The values for donePassed(1), doneWarning(2), and doneError(3) indicate that the test completed either successfully, with a warning, or with an error, respectively. The value aborted(4) is returned for tests which are aborted by setting the value of upsTestId to upsTestAbortTestInProgress. Tests which have not yet concluded are indicated by inProgress(5). The value noTestsInitiated(6) indicates that no previous test results are available, such as is the case when no tests have been run since the last reinitialization of the network management subsystem and the system has no provision for non- volatile storage of test results.ro
Enumeration
.1.3.6.1.4.1.21111.1.1.7.2
upsTstBatteryTestStartTimeThe value of the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated. If the value of upsTestBatteryTestResult is noTestsInitiated(6), upsTestStartTime has the value 01/01/1970 00:00:00. format is (MM/DD/YYYY hh:mm:ss)ro
DisplayString
.1.3.6.1.4.1.21111.1.1.7.3
upsTstBatterySettingTimeThe object specify the test time for battery testrw
INTEGER
.1.3.6.1.4.1.21111.1.1.7.4
upsControl
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.1.8
upsCtlShutdownDelayThe delay in seconds the UPS remains on after being told to turn off. if value=-2 cancel shutdown, if value=-1 donothing, value=0 shutdown ups immediatelyrw
INTEGER (-2..2147483648) UNITS "seconds"
.1.3.6.1.4.1.21111.1.1.8.1
upsCtlSleepTimeThe time in minutes for the UPS to go to sleep when instructed. When in sleep mode, the UPS will not provide output power regardless of the input line state. Once the specified time has elapsed, output power will be restored. This is a configuration setting. The UPS will not go to sleep until told to do so by the manager from a management station. Any input value is allowed, however the UPS only recognizes 0 - 9999 minutes in one minute increments. If the provided value is higher than the highest acceptable value, the highest acceptable value is used.rw
INTEGER (-1..2147483648) UNITS "minutes"
.1.3.6.1.4.1.21111.1.1.8.2
upsCtlStartupAfterDelaySetting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. -1 mean not startup. must set upsCtlStartupAfterDelay before upsCtlShutdownDelayrw
INTEGER
.1.3.6.1.4.1.21111.1.1.8.3
upsCtlbuzzerSetting this object to 'on' or 'off' to enable or disable buzzerrw
Enumeration
.1.3.6.1.4.1.21111.1.1.8.4
upsCtlRemoteControlUPSSetting this object to turn 'on' or 'off' UPSrw
Enumeration
.1.3.6.1.4.1.21111.1.1.8.5
upsCtloutletPoweronSetting this object to 1 means 1st outlet,2 means 2nd outlet , immediately processrw
INTEGER
.1.3.6.1.4.1.21111.1.1.8.6
upsCtloutletPoweroffSetting this object to 1 means 1st outlet, 2 means 2nd outlet , immediately processrw
INTEGER
.1.3.6.1.4.1.21111.1.1.8.7
upsCtlOutlet1Powerofftimesetting this object to -1 means this control not effect, 0 means immediately process, >0 means wait times .use in battery moderw
INTEGER (-1..999) --UNIT "minutes"
.1.3.6.1.4.1.21111.1.1.8.8
upsCtlOutlet2Powerofftimesetting this object to -1 means this control not effect, 0 means immediately process , >0 means wait times .use in battery moderw
INTEGER (-1..999) --UNIT "minutes"
.1.3.6.1.4.1.21111.1.1.8.9
upsCtlResetConfigurereset all configure para to default.rw
Enumeration
.1.3.6.1.4.1.21111.1.1.8.10
agentConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.1.9
agentConfigDatetimeThe datetime in agent, format is (MM/DD/YYYY hh:mm:ss)rw
DisplayString
.1.3.6.1.4.1.21111.1.1.9.1
commConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.1.10
commBaudRateThe UPS communicate baudraterw
Enumeration
.1.3.6.1.4.1.21111.1.1.10.1
commDatabitsThe UPS communicate data bitsrw
INTEGER
.1.3.6.1.4.1.21111.1.1.10.2
commStopbitsThe UPS communicate stop bitsrw
INTEGER
.1.3.6.1.4.1.21111.1.1.10.3
commParityThe UPS communicate Parityrw
Enumeration
.1.3.6.1.4.1.21111.1.1.10.4
commTimeoutThe UPS communicate timeoutrw
INTEGER
.1.3.6.1.4.1.21111.1.1.10.5
upsConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.1.11
upsCfgAlarmbypassSetting this object enable /disable alarm bypass moderw
Enumeration
.1.3.6.1.4.1.21111.1.1.11.1
upsCfgAlarmbatterySetting this object enable/disable alarm battery moderw
Enumeration
.1.3.6.1.4.1.21111.1.1.11.2
upsCfgAutoRebootSetting this object enable/disable auto rebootrw
Enumeration
.1.3.6.1.4.1.21111.1.1.11.3
upsCfgBypasswhenupsoffSetting this object start/stop bypass when ups offrw
Enumeration
.1.3.6.1.4.1.21111.1.1.11.4
upsCfgBatterDDPSetting this object to enable/disable battery deep-discharge protectionrw
Enumeration
.1.3.6.1.4.1.21111.1.1.11.5
upsCfgConvertermodeSetting this object to enable/disable converter moderw
Enumeration
.1.3.6.1.4.1.21111.1.1.11.6
upsCfgECOmodeSetting this object to enable/disable ECO moderw
Enumeration
.1.3.6.1.4.1.21111.1.1.11.7
upsCfgAdvanceECOmodeSetting this object to enable/disable advance ECO moderw
Enumeration
.1.3.6.1.4.1.21111.1.1.11.8
upsCfgGreenPowerFunctionSetting this object to enable/disable green power functionrw
Enumeration
.1.3.6.1.4.1.21111.1.1.11.9
upsCfgBatteryOSCSetting this object to enable/disable battery open status checkrw
Enumeration
.1.3.6.1.4.1.21111.1.1.11.10
upsCfgAllowShort3timesSetting this object to enable/disable short 3 timesrw
Enumeration
.1.3.6.1.4.1.21111.1.1.11.11
upsCfgColdstartSetting this object to cold start upsrw
Enumeration
.1.3.6.1.4.1.21111.1.1.11.12
upsCfgBypassNotAllowedSetting this object to enable/disable bypass moderw
Enumeration
.1.3.6.1.4.1.21111.1.1.11.13
upsCfgBatterylowprotectSetting this object to enable/disable battery low protectrw
Enumeration
.1.3.6.1.4.1.21111.1.1.11.14
upsCfgP1progoutletcontrolSetting this object to enable/disable p1 programmable outlet control (battery mode)rw
Enumeration
.1.3.6.1.4.1.21111.1.1.11.15
upsCfgP2progoutletcontrolSetting this object to enable/disable p2 programmable outlet control (battery mode)rw
Enumeration
.1.3.6.1.4.1.21111.1.1.11.16
upsCfgInverterShortClearSetting this object to enable/disable Inverter short clear functionrw
Enumeration
.1.3.6.1.4.1.21111.1.1.11.17
upsCfgSitefaildetectionSetting this object to enable/disable site fail detectionrw
Enumeration
.1.3.6.1.4.1.21111.1.1.11.18
upsCfgBatNumInParallelBattery numbers in parallel (battery numbers setting)rw
INTEGER
.1.3.6.1.4.1.21111.1.1.11.19
upsCfgBatNumInSeriesBattery numbers in series (battery numbers setting)rw
INTEGER
.1.3.6.1.4.1.21111.1.1.11.20
upsCfgBypassmaxvoltageBypass mode max voltagerw
INTEGER
.1.3.6.1.4.1.21111.1.1.11.21
upsCfgBypassminvoltageBypass mode min voltagerw
INTEGER
.1.3.6.1.4.1.21111.1.1.11.22
upsCfgBypassmaxfrequencyBypass mode max frequencyrw
INTEGER (510..600,610..700) SYNTAX INTEGER
.1.3.6.1.4.1.21111.1.1.11.23
upsCfgBypassminfrequencyBypass mode min frequencyrw
INTEGER (400..490,500..590) SYNTAX INTEGER
.1.3.6.1.4.1.21111.1.1.11.24
upsCfgECOmaxvoltageECO mode max voltagerw
INTEGER
.1.3.6.1.4.1.21111.1.1.11.25
upsCfgECOminvoltageECO mode min voltagerw
INTEGER
.1.3.6.1.4.1.21111.1.1.11.26
upsCfgFreeRunMaxFrequencyFree run mode max frequencyrw
INTEGER
.1.3.6.1.4.1.21111.1.1.11.27
upsCfgFreeRunMinFrequencyFree run mode min frequencyrw
INTEGER
.1.3.6.1.4.1.21111.1.1.11.28
upsCfgEPOStatusGet EPO status,configured by mamualro
Enumeration
.1.3.6.1.4.1.21111.1.1.11.29
upsCfgQSK1StatusGet QSK 1 statusro
Enumeration
.1.3.6.1.4.1.21111.1.1.11.30
upsCfgQSK2StatusGet QSK 2 statusro
Enumeration
.1.3.6.1.4.1.21111.1.1.11.31
upsCfgQSKT1DelaytimeGet QSKT 1 time delayro
INTEGER
.1.3.6.1.4.1.21111.1.1.11.32
upsCfgQSKT2DelaytimeGet QSKT 2 time delayro
INTEGER
.1.3.6.1.4.1.21111.1.1.11.33
upsCfgConstantPhaseAnglesetting this object to Enable/disable Constant Phase Angle functionrw
Enumeration
.1.3.6.1.4.1.21111.1.1.11.34
upsCfgInPhaseAngleGet input phase anglero
Enumeration
.1.3.6.1.4.1.21111.1.1.11.35
upsCfgOutPhaseAngleSet output phase anglerw
Enumeration
.1.3.6.1.4.1.21111.1.1.11.36
upsCfgLimiRunOnBatModeEnable/disable limited runtime on battery moderw
Enumeration
.1.3.6.1.4.1.21111.1.1.11.37
upsCfgChargingCurrentSet charging current to battery .ro
INTEGER UNITS "0.1 Amp DC"
.1.3.6.1.4.1.21111.1.1.11.38
upsCfgBatSeftCheckVoltBatTest until battery voltage lower than <nnn>rw
INTEGER
.1.3.6.1.4.1.21111.1.1.11.39
upsCfgOverChargVoltset over charging voltage to per batteryrw
INTEGER
.1.3.6.1.4.1.21111.1.1.11.40
upsCfgBattUnderVoltset battery under voltage of setting value.value is a number ranging from 200V to 240Vrw
INTEGER
.1.3.6.1.4.1.21111.1.1.11.41
upsCfgBattLowVoltset battery low voltage of setting value.it is 10 to 40V high than battery under voltage. it is 10 to 40V high than battery under voltage.default 20. it means that the battery low point is battery under add 20. for example, if the battery under voltage is 210V, the battry low point voltage is 230V.rw
INTEGER UNITS "0.1 Volts"
.1.3.6.1.4.1.21111.1.1.11.42
upsCfgIn1VoltHLossset input1 voltage high loss point.rw
INTEGER UNITS "0.1 Volts"
.1.3.6.1.4.1.21111.1.1.11.43
upsCfgIn1VoltLLossset input1 voltage low loss point.rw
INTEGER UNITS "0.1 Volts"
.1.3.6.1.4.1.21111.1.1.11.44
upsCfgIn2VoltHLossset input2 voltage high loss point.rw
INTEGER UNITS "0.1 Volts"
.1.3.6.1.4.1.21111.1.1.11.45
upsCfgIn2VoltLLossset input2 voltage low loss point.rw
INTEGER UNITS "0.1 Volts"
.1.3.6.1.4.1.21111.1.1.11.46
upsCfgBatteryTurnOnEnable/disable battery turn on.rw
Enumeration
.1.3.6.1.4.1.21111.1.1.11.47
upsTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.1.12
cmpACFailureAC failure
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.1
cmpFanFailureFan failure
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.2
cmpUPSFailureUPS failure
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.3
cmpChargerFailureCharger failure
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.4
cmpOverloadFailureOverload failure
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.5
cmpOvertempFailureOver temperature fault.
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.6
cmpInvertershortcircuitedInverter short-circuited
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.7
cmpbatteryfusebeingocBattery fuse being open-dcircuited failure
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.8
cmpLowbatteryThe UPS has returned from a low battery condition.
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.9
cmpSysgotoshutdownSystem is going to shutdown
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.10
cmpSitefaultSite fault
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.11
cmpPhasesequenceincorrectPhase sequence incorrect
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.12
cmpPhasesequenceincorrectbypassPhase sequence incorrect in bypass
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.13
cmpFanalarmFan alarm.
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.14
cmpEPOenabledEPO enabled
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.15
cmpUnabletotrunonUPSUnalbe to turn on UPS
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.16
cmpOvertemperaturealarmOver temperature alarm
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.17
cmpInputfrequnstablebypassInput frequency unstable in bypass
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.18
cmpChargeralarmCharger alarm
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.19
cmpL1inputfusenotworkL1 input fuse not working
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.20
cmpNeutralnotConnectedNeutral not connected
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.21
cmpL2inputfusenotworkL2 input fuse not working
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.22
cmpL3inputfusenotworkL3 input fuse not working
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.23
cmpPositivePFCabnormalL1Positive PFC abnormal in L1
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.24
cmpNegativePFCabnormalL1Negative PFC abnormal in L1
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.25
cmpPositivePFCabnormalL2Positive PFC abnormal in L2
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.26
cmpNegativePFCabnormalL2Negative PFC abnormal in L2
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.27
cmpPositivePFCabnormalL3Positive PFC abnormal in L3
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.28
cmpNegativePFCabnormalL3Negative PFC abnormal in L3
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.29
cmpBusvoltagenotwdsBus voltage not within default setting
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.30
cmpBusvoltageovermaxvalueBus voltage over maxinum value
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.31
cmpBusvoltagebelowminvalueBus voltage below mininum value
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.32
cmpBusvoltagediffoutofrangeBus voltage differences out fo acceptable range
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.33
cmpBusvoltageofsloperatetoofastBus voltage of slope rate drops too fast
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.34
cmpOvercurrentinPFCIIWARNING:Over current in PFC input inductor.
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.35
cmpInvertervoloutofrangeInverter voltage not within default setting.
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.36
cmpInvertervolovermaxvalueInverter voltage over maximum value.
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.37
cmpInvertervolbelowminvalueInverter voltage below minimum value.
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.38
cmpBatteryoppositelyconnectedBattery oppositely connected.
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.39
cmpL2phaseshortcicuitedL2Phase inverter short-cicuited.
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.40
cmpL3phaseshortcicuitedL3Phase inverter short-cicuited.
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.41
cmpL1L2invertershortcicuitedL1L2Inverter short-cicuited.
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.42
cmpL2L3invertershortcicuitedL2L3Inverter short-cicuited.
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.43
cmpL3L1invertershortcicuitedL3L1Inverter short-cicuited.
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.44
cmpL1negativepoweroutofrangeL1 inverter negative powere out of acceptable range.
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.45
cmpL2negativepoweroutofrangeL2 inverter negative powere out of acceptable range.
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.46
cmpL3negativepoweroutofrangeL3 inverter negative powere out of acceptable range.
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.47
cmpBatterySCRshortcircuitedBattery SCR short-circuited.
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.48
cmpLineSCRshortcircuitedLine SCR short-circuited.
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.49
cmpInverterrelayopenfaultInverter relay open fault.
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.50
cmpInverterrelayshortcircuitedInverter relay short-circuited.
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.51
cmpInoutwiresoppositelyconnectedInput and output wires oppositely connected.
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.52
cmpabnormalcanbuscommunicationAbnormal in CAN-bus communication.
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.53
cmpcommfailurebcupsboardCommunication failure between cpus in control board.Or DSP and MCU communication error
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.54
cmpabnormalsyncsignalcircuitAbnomal in synchronous signal circuit.
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.55
cmpabnormalsyncpulsesignalcircuitAbnomal in synchronous pulse signal circuit.
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.56
cmpcurrent3punbalancedetectedWarning for a three-phase input current unbalance detected.
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.57
cmpbatteryselftestfailureBattery self-test failure.
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.58
cmpintercurrentunbalanceInverter inter-current unbalance.
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.59
cmpbatterydisconnectedBattery disconnected.
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.60
cmpabnormalhostsignalcircuitAbnormal in host signal circuit.
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.61
cmpbatteryoverchargedBettery overcharged.
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.62
cmpbatteryvoltoohighBettery voltage is too high.
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.63
cmpbatteryvoltoolowBettery voltage is too low.
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.64
cmpfemaleconnectornotconnwellFemale connector of parallel cable not connected well.
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.65
cmpmaleconnectornotconnwellMale connector of parallel cable not connected well.
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.66
cmplockingbypassA3COW30MLocking inbypass mode after 3 consecutive overloads within 30 minutes
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.67
cmpparallelcabledisconnectedParallel cable disconnected
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.68
cmpsyncpulsecircuitfaultSynchronous pulse signal circuit fault
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.69
cmpsyncsignalcircuitfaltSynchronous signal circuit fault
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.70
cmphostsignalcircuitfaultHost signal circuit fault
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.71
cmpcanbuscommunicationfaultCan-bus communication fault
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.72
cmplowlosspointforvolinACmodeLow loss point for voltage in ac mode not consistent in parallel systems
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.73
cmphighlosspointforvolinACmodeHigh loss point for voltage in ac mode not consistent in parallel systems
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.74
cmplowlosspointforfreqinACmodeLow loss point for frequency in ac mode not consistent in parallel systems
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.75
cmphighlosspointforfreqinACmodeHigh loss point for frequency in ac mode not consistent in parallel systems
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.76
cmplowlosspointforvolinbypassmodeLow loss point for voltage in bypass mode not consistent in parallel systems
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.77
cmphighlosspointforvolinbypassmodeHigh loss point for voltage in bypass mode not consistent in parallel systems
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.78
cmplowlosspointforfreqinbypassmodeLow loss point for frequency in bypass mode not consistent in parallel systems
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.79
cmphighlosspointforfreqinbypassmodeHigh loss point for frequency in bypass mode not consistent in parallel systems
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.80
cmploadunbalancedLoad unbalanced
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.81
cmpoverloadalarmOverload alarm
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.82
cmpparallelnotconnectedwellParallel cable not connected well
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.83
cmpcommunicationlostCommunication lost
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.84
cmpbatteryconnnotsonsistentBattery connection not consistent in parallel systems
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.85
cmpconverternotconsisstentConverter setting not consistent in parallel systems
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.86
cmpbypassnotallownotconsistentBypass not allowed setting not consistent in parallel systems
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.87
cmpACconnnotconsistentAC connection not consistent in parallel systems
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.88
cmpinput3pcurrentunbalanceWarning for three-phase ac input current unbalance
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.89
cmpbypassconnnotconsistentBypass connection not consistent in parallel systems
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.90
cmpbatteryprotectionnotconsistentBattery protection setting not consistent in parallel systems
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.91
cmpbatterydetectionnotconsistentBattery detection setting not consistent in parallel systems
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.92
cmpupsmodeltypesnotconsistentUPS model types not consistent in parallel systems
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.93
cmpbypassnotconsistentBypass setting not consistent in parallel systems
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.94
cmpcapacitynotconsistentCapacity of upss not consistent in parallel systems
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.95
cmpautorestartnotconsistentAuto restart setting not consistent in parallel systems
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.96
cmpBatteryReplaceBattery need to be replace
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.97
cmpACNormalAC normal
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.100
cmpOutputBadAlarmOutput bad alarm
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.103
cmpBypassBadAlarmBypass bad alarm
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.104
cmpOutputOffAlarmOutput off alarm
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.105
cmpUPSShutAlarmUPS shutdown alarm
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.106
cmpSystemOffAlarmSystem off alarm
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.107
cmpFuseFailureAlarmFuse failure alarm
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.108
cmpGenFailureAlarmGeneral failure alarm
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.109
cmpAwaitPowerAlarmAwaiting power alarm
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.110
cmpShutPendingAlarmShutdown pending alarm
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.111
cmpBatDepletedBattery depleted
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.112
cmpUnknowStatusBattery unknow status
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.113
cmpOutputOnOutput on
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.114
cmpTurntobypassUps turn to bypass mode
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.115
cmpTurntobatteryUps turn to battery mode
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.116
cmpOutBoosterTurn to booster
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.117
cmpOutReducerTurn to reducer
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.118
cmpOutBattestTurn to battery test mode
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.119
cmpOtherSourceOther source
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.120
cmpBatfailureBattery failure
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.121
cmpBatTestDonePassedBattery test passed
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.122
cmpBatTestDoneWarningBattery test done warning
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.123
cmpBatTestDoneAbortedBattery test done Aborted
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.124
cmpBatteryNormalBattery normal
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.125
cmpBatteryDischargingBattery Discharging
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.126
cmpP1cutoffprealarmP1 cut off pre-alarm
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.127
cmpInputPhaseErrorWarning for input phase error for LV 6-10K UPS
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.128
cmpMaintainSwitchOpenalarmWarning for maintain switch open
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.129
cmpEMDChAbnormal1EMD Channels 1 Abnormal
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.130
cmpEMDChAbnormal2EMD Channels 2 Abnormal
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.131
cmpEMDChAbnormal3EMD Channels 3 Abnormal
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.132
cmpEMDChAbnormal4EMD Channels 4 Abnormal
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.133
cmpEMDChAbnormal5EMD Channels 5 Abnormal: smoke alarm
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.134
cmpEMDChAbnormal6EMD Channels 6 Abnormal
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.135
cmpEMDChAbnormal7EMD Channels 7 Abnormal
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.136
cmpEMDChAbnormal8EMD Channels 8 Abnormal
TRAP-TYPE
.1.3.6.1.4.1.21111.1.1.12.0.137
trapleafnodev103The share trap-node for send all traps,snmpcard V1-03 and later use this trap-node char trap[16]; trap[0]: trap[0]=1,fault trap ; trap[0]=0,warn trap
DisplayString
.1.3.6.1.4.1.21111.1.1.12.998
trapleafnodev1v2The share trap-node for send all traps
INTEGER
.1.3.6.1.4.1.21111.1.1.12.999
extend
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.1.13
extendWorkTemperatureThe temperature of work environmentro
INTEGER (-2200..2200) UNITS "degrees 0.1 Centigrade"
.1.3.6.1.4.1.21111.1.1.13.1
extendWorkhumidityThe humidity of work environmentro
INTEGER
.1.3.6.1.4.1.21111.1.1.13.2
extendSmokeScopeThe smokeScope of work environmentro
INTEGER
.1.3.6.1.4.1.21111.1.1.13.3
extendEMDAlarm1Environment detector alarm 1ro
Enumeration
.1.3.6.1.4.1.21111.1.1.13.4
extendEMDAlarm2Environment detector alarm 2ro
Enumeration
.1.3.6.1.4.1.21111.1.1.13.5
extendEMDAlarm3Environment detector alarm 3ro
Enumeration
.1.3.6.1.4.1.21111.1.1.13.6
extendEMDAlarm4Environment detector alarm 4ro
Enumeration
.1.3.6.1.4.1.21111.1.1.13.7
inverter
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.2
solarIdent
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.2.1
solarIdManufacturerThe name of the solar manufacturer.ro
DisplayString
.1.3.6.1.4.1.21111.1.2.1.1
solarIdProtocolThe solar Protocol id.ro
Enumeration
.1.3.6.1.4.1.21111.1.2.1.2
solarIdModelNameThe solar Model designation.ro
DisplayString
.1.3.6.1.4.1.21111.1.2.1.3
solarIdSerialNumberThe solar serial no.ro
DisplayString
.1.3.6.1.4.1.21111.1.2.1.4
solarIdFWVersionMain CPU firmware version.ro
DisplayString
.1.3.6.1.4.1.21111.1.2.1.5
solarIdFW2VersionMain CPU 2 firmware version.ro
DisplayString
.1.3.6.1.4.1.21111.1.2.1.6
solarIdSolarTypesolar type.ro
Enumeration
.1.3.6.1.4.1.21111.1.2.1.7
solarIdTopologysolar Topology.ro
Enumeration
.1.3.6.1.4.1.21111.1.2.1.8
solarIdCriterionsolar device criterion.ro
INTEGER
.1.3.6.1.4.1.21111.1.2.1.9
solarRating
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.2.2
solarRatOutPowerThe rating Output Power of solar inverterro
NonNegativeInteger UNITS "0.1 Wt"
.1.3.6.1.4.1.21111.1.2.2.1
solarRatApparentPowerThe rating output apparent power of solar inverterro
NonNegativeInteger UNITS "0.1 VA"
.1.3.6.1.4.1.21111.1.2.2.2
solarRatGridVoltageThe rating output voltage of solar inverterro
NonNegativeInteger UNITS "0.1 vol"
.1.3.6.1.4.1.21111.1.2.2.3
solarRatGridFrequencyThe rating grid frequency of solar inverterro
NonNegativeInteger UNITS "0.1 Hz"
.1.3.6.1.4.1.21111.1.2.2.4
solarRatGridCurrentThe rating grid current of solar inverterro
NonNegativeInteger UNITS "0.1 A"
.1.3.6.1.4.1.21111.1.2.2.5
solarRatPerMPPTCurrentPer MPPT rating currentro
NonNegativeInteger UNITS "0.1 A"
.1.3.6.1.4.1.21111.1.2.2.6
solarRatPVInputVoltageNominal device Voltage,pv input Voltagero
NonNegativeInteger UNITS "0.1 vol"
.1.3.6.1.4.1.21111.1.2.2.7
solarRatACOutVoltageThe rating AC output voltage of solar inverterrw
NonNegativeInteger{ a(208),b(220),c(230),d(240)} UNITS "0.1 vol"
.1.3.6.1.4.1.21111.1.2.2.8
solarRatACOutCurrentThe rating AC output current of solar inverterro
NonNegativeInteger UNITS "0.1 A"
.1.3.6.1.4.1.21111.1.2.2.9
solarRatBatVoltageThe rating battery voltage of solar inverterro
NonNegativeInteger UNITS "0.1 vol"
.1.3.6.1.4.1.21111.1.2.2.10
solarBattery
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.2.3
solarBatStatusThe indication of the status in the solar system's batteries.ro
Enumeration
.1.3.6.1.4.1.21111.1.2.3.1
solarBatSecondsOnBatteryIf the unit is on battery power, the elapsed time since the solar last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. -1 shall be returned if the unit is not on battery power.ro
INTEGER UNITS "seconds"
.1.3.6.1.4.1.21111.1.2.3.2
solarBatEstMinutesRemainingAn estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.ro
INTEGER UNITS "minutes"
.1.3.6.1.4.1.21111.1.2.3.3
solarBatEstChargeRemainingAn estimate of the battery charge remaining expressed as a percent of full charge.ro
INTEGER
.1.3.6.1.4.1.21111.1.2.3.4
solarBatPBatVoltageThe magnitude of the present Positive battery voltage.ro
NonNegativeInteger UNITS "0.1 Volt DC"
.1.3.6.1.4.1.21111.1.2.3.5
solarBatNBatVoltageThe magnitude of the present negative battery voltage.ro
NonNegativeInteger UNITS "0.1 Volt DC"
.1.3.6.1.4.1.21111.1.2.3.6
solarBatPBatCurrentThe positive battery present current.ro
INTEGER UNITS "0.1 Amp DC"
.1.3.6.1.4.1.21111.1.2.3.7
solarBatNBatCurrentThe present negative battery current.ro
INTEGER UNITS "0.1 Amp DC"
.1.3.6.1.4.1.21111.1.2.3.8
solarBatPBatChargCurrentThe Positive battery charging current.ro
INTEGER UNITS "0.1 Amp DC"
.1.3.6.1.4.1.21111.1.2.3.9
solarBatNBatchargCurrentThe present negative battery charging current.ro
INTEGER UNITS "0.1 Amp DC"
.1.3.6.1.4.1.21111.1.2.3.10
solarBatPBatDischargCurrentThe present positive battery discharging current.ro
INTEGER UNITS "0.1 Amp DC"
.1.3.6.1.4.1.21111.1.2.3.11
solarBatNBatDischargCurrentThe present negative battery discharging current.ro
INTEGER UNITS "0.1 Amp DC"
.1.3.6.1.4.1.21111.1.2.3.12
solarBatTemperatureThe ambient temperature at or near the solar Battery casing.ro
INTEGER UNITS "degrees 0.1 Centigrade"
.1.3.6.1.4.1.21111.1.2.3.13
solarBatNumberInSeriesThe number of battery in series.ro
PositiveInteger (UPS-MIB)
.1.3.6.1.4.1.21111.1.2.3.14
solarBatNumberInParallelThe number of battery in Parallel.ro
PositiveInteger (UPS-MIB)
.1.3.6.1.4.1.21111.1.2.3.15
solarBatChargingCurrentCharging Current.ro
INTEGER
.1.3.6.1.4.1.21111.1.2.3.16
solarGrid
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.2.4
solarGridSourceThe present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.==UPS standby modero
Enumeration
.1.3.6.1.4.1.21111.1.2.4.1
solarGridTtlApparentPowerTotal grid output apparent power .ro
INTEGER UNITS "0.1VA"
.1.3.6.1.4.1.21111.1.2.4.2
solarGridTtlTruePowerTotal grid output active(true) power .ro
INTEGER UNITS "0.1Watts"
.1.3.6.1.4.1.21111.1.2.4.3
solarGridFrequencyTotal grid frequency.ro
NonNegativeInteger UNITS "0.1Hz"
.1.3.6.1.4.1.21111.1.2.4.4
solarGridNumLineThe number of output lines utilized in this device. This variable indicates the number of rows in the output table.ro
INTEGER
.1.3.6.1.4.1.21111.1.2.4.5
solarGridTemperatureMax Temperature of the detecting pointers.ro
INTEGER UNITS "degrees 0.1 Centigrade"
.1.3.6.1.4.1.21111.1.2.4.6
solarGridStatusDevice status. b31-b16:NG b15: NG b14: NG b13: NG b12: NG b11: Load status 0: Load off 1:Load on b10: Battery status b9: Battery status b10b9: 00: Do nothing 01: Charging 10: Discharging b8: Inv direction 0: DC-AC 1: AC-DC b7: Line direction b6: Line direction a7a6: 00 means unsteady 01 means Line input 10 means Line output b5-b0:NGro
INTEGER UNITS ""
.1.3.6.1.4.1.21111.1.2.4.7
solarGridTableA list of solar grid table entries. The number of entries is given by the value of solarGridputNumLines.
SEQUENCE OF SolarGridEntry
.1.3.6.1.4.1.21111.1.2.4.8
solarGridEntryAn entry containing information applicable to a particular grid line.
SolarGridEntry
.1.3.6.1.4.1.21111.1.2.4.8.1
solarGridLineIndexThe grid line identifier.ro
INTEGER
.1.3.6.1.4.1.21111.1.2.4.8.1.1
solarGridVoltageThe Grid voltage of the solar inverterro
INTEGER UNITS "0.1 Volts"
.1.3.6.1.4.1.21111.1.2.4.8.1.2
solarGridCurrentThe Grid current of the solar inverterro
INTEGER UNITS "0.1 Amp"
.1.3.6.1.4.1.21111.1.2.4.8.1.3
solarGridPowerThe present Grid output true power.ro
INTEGER UNITS "0.1Watts"
.1.3.6.1.4.1.21111.1.2.4.8.1.4
solarACOutput
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.2.5
solarACOutNumLinesAC output lines number.ro
NonNegativeInteger (UPS-MIB)
.1.3.6.1.4.1.21111.1.2.5.1
solarACOutFrequencyAC output frequency .ro
NonNegativeInteger UNITS "0.1Hz"
.1.3.6.1.4.1.21111.1.2.5.2
solarACOutTtlPowerTotal AC output total active(true) power .ro
NonNegativeInteger UNITS "0.1WT"
.1.3.6.1.4.1.21111.1.2.5.3
solarACOutTtlPercentLoadTotal AC output total percent load.ro
INTEGER
.1.3.6.1.4.1.21111.1.2.5.4
solarACOutTableA list of AC output table entries. The number of entries is given by the value of solarACOut NumLines.
SEQUENCE OF SolarACOutEntry
.1.3.6.1.4.1.21111.1.2.5.5
solarACOutEntryAn entry containing information applicable to a particular input line.
SolarACOutEntry
.1.3.6.1.4.1.21111.1.2.5.5.1
solarACOutLineIndexThe number of PV line identifier.ro
INTEGER
.1.3.6.1.4.1.21111.1.2.5.5.1.1
solarACOutVoltageThe AC output voltage .ro
INTEGER UNITS "0.1 Volts"
.1.3.6.1.4.1.21111.1.2.5.5.1.2
solarACOutTruePowerThe magnitude of the present AC output true power.ro
NonNegativeInteger UNITS "0.1Watts"
.1.3.6.1.4.1.21111.1.2.5.5.1.3
solarACOutCurrentThe magnitude of the present AC output current.ro
INTEGER UNITS "0.1A"
.1.3.6.1.4.1.21111.1.2.5.5.1.4
solarACOutPercentLoadThe magnitude of the present AC output percent loadro
INTEGER
.1.3.6.1.4.1.21111.1.2.5.5.1.5
solarPV
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.2.6
solarPVNumLinesPV input lines number.rw
NonNegativeInteger
.1.3.6.1.4.1.21111.1.2.6.1
solarPVTtlPowerTotal PV input active(true) power .ro
NonNegativeInteger UNITS "0.1WT"
.1.3.6.1.4.1.21111.1.2.6.2
solarPVTableA list of solar PV input table entries. The number of entries is given by the value of solarPV NumLines.
SEQUENCE OF SolarPVEntry
.1.3.6.1.4.1.21111.1.2.6.3
solarPVEntryAn entry containing information applicable to a particular input line.
SolarPVEntry
.1.3.6.1.4.1.21111.1.2.6.3.1
solarPVLineIndexThe number of PV line identifier.ro
INTEGER
.1.3.6.1.4.1.21111.1.2.6.3.1.1
solarPVVoltageThe PV input voltage .ro
INTEGER UNITS "0.1 Volts"
.1.3.6.1.4.1.21111.1.2.6.3.1.2
solarPVPowerThe magnitude of the present input true power.ro
NonNegativeInteger UNITS "0.1Watts"
.1.3.6.1.4.1.21111.1.2.6.3.1.3
solarEnergy
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.2.7
solarEnergyFirstTimeEnergythe time when the user fist storage capacityro
DisplayString
.1.3.6.1.4.1.21111.1.2.7.1
solarEnergyHourTwrite the hour when we will inquiry energy in the hourrw
DisplayString
.1.3.6.1.4.1.21111.1.2.7.2
solarEnergyHourE0xfeffffff:doing inquiry 0xffffffff:errorro
DisplayString
.1.3.6.1.4.1.21111.1.2.7.3
solarEnergyDayTthe time when we will inquiry energy in the dayrw
DisplayString
.1.3.6.1.4.1.21111.1.2.7.4
solarEnergyDayE0xfeffffff:doing inquiry 0xffffffff:errorro
DisplayString
.1.3.6.1.4.1.21111.1.2.7.5
solarEnergyMonTthe timerw
DisplayString
.1.3.6.1.4.1.21111.1.2.7.6
solarEnergyMonE0xfeffffff:doing inquiry 0xffffffff:errorro
DisplayString
.1.3.6.1.4.1.21111.1.2.7.7
solarEnergyYearTThe timerw
DisplayString
.1.3.6.1.4.1.21111.1.2.7.8
solarEnergyYearE0xfeffffff:doing inquiry 0xffffffff:errorro
DisplayString
.1.3.6.1.4.1.21111.1.2.7.9
solarEnergyHourIDID.ro
INTEGER
.1.3.6.1.4.1.21111.1.2.7.10
solarEnergyDayIDID.ro
INTEGER
.1.3.6.1.4.1.21111.1.2.7.11
solarEnergyMonIDID.ro
INTEGER
.1.3.6.1.4.1.21111.1.2.7.12
solarEnergyYearIDID.ro
INTEGER
.1.3.6.1.4.1.21111.1.2.7.13
solarTest
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.2.8
solarTestStartSelfTestSetting this object to 'start' to start testrw
Enumeration
.1.3.6.1.4.1.21111.1.2.8.1
solarTestSelfTestResultan Integer ranging from 0 to 9. 0 means self test being processed, 1 means self test succeed, 2 means self test fail.ro
Enumeration
.1.3.6.1.4.1.21111.1.2.8.2
solarTestGridOutHVolSelf test grid output high voltagero
INTEGER UNITS "0.1 Volt"
.1.3.6.1.4.1.21111.1.2.8.3
solarTestGridOutLVolSelf test grid output low voltagero
INTEGER UNITS "0.1 Volt"
.1.3.6.1.4.1.21111.1.2.8.4
solarTestGridOutHFreqSelf test grid output high frequencyro
INTEGER UNITS "0.1 Hz"
.1.3.6.1.4.1.21111.1.2.8.5
solarTestGridOutLFreqSelf test grid output low frequencyro
INTEGER UNITS "0.1 VA"
.1.3.6.1.4.1.21111.1.2.8.6
solarTestChOutHVolThe check time of self test grid output high voltagero
NonNegativeInteger UNITS "ms"
.1.3.6.1.4.1.21111.1.2.8.7
solarTestChOutLVolThe check time of self test grid output low voltagero
NonNegativeInteger UNITS "ms"
.1.3.6.1.4.1.21111.1.2.8.8
solarTestChOutHFreqThe check time of self test grid output high frequencyro
NonNegativeInteger UNITS "ms"
.1.3.6.1.4.1.21111.1.2.8.9
solarTestChOutLFreqThe check time of self test grid output low frequencyro
NonNegativeInteger UNITS "ms"
.1.3.6.1.4.1.21111.1.2.8.10
solarDefValue
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.2.9
solarDefGridOutVolHLossThe default setting value of grid output voltage high loss pointro
INTEGER UNITS "0.1 Volt DC"
.1.3.6.1.4.1.21111.1.2.9.1
solarDefGridOutVolLLossThe default setting value of grid output voltage lowloss pointro
INTEGER UNITS "0.1 Volt DC"
.1.3.6.1.4.1.21111.1.2.9.2
solarDefGridOutFreqHLossThe default setting value Grid output frequency high loss pointro
INTEGER UNITS "0.1 HZ"
.1.3.6.1.4.1.21111.1.2.9.3
solarDefGridOutFreqLLossThe default setting value Grid output frequency low loss pointro
INTEGER UNITS "0.1 HZ"
.1.3.6.1.4.1.21111.1.2.9.4
solarDefGridInVolHLossThe default setting value Grid input voltage high loss pointro
INTEGER UNITS "0.1 VA"
.1.3.6.1.4.1.21111.1.2.9.5
solarDefGridInVolLLossThe default setting value Grid input voltage low loss pointro
INTEGER UNITS "0.1 Wt"
.1.3.6.1.4.1.21111.1.2.9.6
solarDefGridInFreqHLossThe default setting value Grid input frequency high loss pointro
INTEGER UNITS "0.1 vol"
.1.3.6.1.4.1.21111.1.2.9.7
solarDefGridInFreqLLossThe default setting value Grid input frequency low loss pointro
INTEGER UNITS "0.1 Wt"
.1.3.6.1.4.1.21111.1.2.9.8
solarDefUpLimitPVVolThe default setting value The upper limit of PV input voltagero
INTEGER UNITS "0.1 vol"
.1.3.6.1.4.1.21111.1.2.9.9
solarDefLowLimitPVVolThe default setting value The lowest limit of PV input voltagero
INTEGER UNITS "0.1 vol"
.1.3.6.1.4.1.21111.1.2.9.10
solarDefPVHVolMPPTThe default setting value The PV input high voltage for MPPTro
INTEGER UNITS "0.1 Wt"
.1.3.6.1.4.1.21111.1.2.9.11
solarDefPVLVolMPPTThe default setting value The PV input low voltage for MPPTro
INTEGER UNITS "0.1 vol"
.1.3.6.1.4.1.21111.1.2.9.12
solarDefMaxOutPowerThe default setting value Max output powerro
INTEGER UNITS "0.1 vol"
.1.3.6.1.4.1.21111.1.2.9.13
solarDefAverageVolHLossThe default setting value Long time grid average voltage high loss pointro
INTEGER UNITS "0.1 Wt"
.1.3.6.1.4.1.21111.1.2.9.14
solarDefLCDSleepTimeThe default setting value LCD sleep timero
INTEGER UNITS "30s"
.1.3.6.1.4.1.21111.1.2.9.15
solarDefBatteryNumThe default setting value Battery piece numberro
NonNegativeInteger (UPS-MIB)
.1.3.6.1.4.1.21111.1.2.9.16
solarDefBattTtlCapacitThe default setting value Battery total capacityro
NonNegativeInteger UNITS "0.1 Ah"
.1.3.6.1.4.1.21111.1.2.9.17
solarDefChargerCurrentThe default setting value Charger currentro
NonNegativeInteger UNITS "0.1 A"
.1.3.6.1.4.1.21111.1.2.9.18
solarDefMaxChargeVolThe default setting the max charging voltagero
INTEGER UNITS "0.1 V"
.1.3.6.1.4.1.21111.1.2.9.19
solarDefMaxChargeCurrThe default setting the max charging currentro
INTEGER UNITS "0.1 A"
.1.3.6.1.4.1.21111.1.2.9.20
solarDefWaiteTimeFeedThe default setting waiting time for feedingro
INTEGER
.1.3.6.1.4.1.21111.1.2.9.21
solarDefMaxGridOutVolHLossThe max grid output voltage high loss pointro
INTEGER UNITS "0.1 Volt DC"
.1.3.6.1.4.1.21111.1.2.9.22
solarDefMinGridOutVolHLossThe min grid output voltage high loss pointro
INTEGER UNITS "0.1 Volt DC"
.1.3.6.1.4.1.21111.1.2.9.23
solarDefMaxGridOutVolLLossThe max grid output voltage low loss pointro
INTEGER UNITS "0.1 Volt DC"
.1.3.6.1.4.1.21111.1.2.9.24
solarDefMinGridOutVolLLossThe min grid output voltage low loss pointro
INTEGER UNITS "0.1 Volt DC"
.1.3.6.1.4.1.21111.1.2.9.25
solarDefMaxGridOutFreqHLossThe max grid output frequency high loss pointro
INTEGER UNITS "0.1 HZ"
.1.3.6.1.4.1.21111.1.2.9.26
solarDefMinGridOutFreqHLossThe min grid output frequency high loss pointro
INTEGER UNITS "0.1 HZ"
.1.3.6.1.4.1.21111.1.2.9.27
solarDefMaxGridOutFreqLLossThe max grid output frequency low loss pointro
INTEGER UNITS "0.1 HZ"
.1.3.6.1.4.1.21111.1.2.9.28
solarDefMinGridOutFreqLLossThe min grid output frequency low loss pointro
INTEGER UNITS "0.1 HZ"
.1.3.6.1.4.1.21111.1.2.9.29
solarDefMaxWaiteTimeFeedThe max waiting time for feedingro
INTEGER
.1.3.6.1.4.1.21111.1.2.9.30
solarDefMinWaiteTimeFeedThe min waiting time for feedingro
INTEGER
.1.3.6.1.4.1.21111.1.2.9.31
solarDefMaxMaxFChargVoltThe max voltage for max floating charging voltagero
INTEGER
.1.3.6.1.4.1.21111.1.2.9.32
solarDefMinMaxFChargVoltThe min voltage for max floating charging voltagero
INTEGER
.1.3.6.1.4.1.21111.1.2.9.33
solarDefMaxMaxRChargCurrThe upper limit of max charging current(real charging)ro
INTEGER
.1.3.6.1.4.1.21111.1.2.9.34
solarDefMinMaxRChargCurrThe lower limit of max charging current(real charging)ro
INTEGER
.1.3.6.1.4.1.21111.1.2.9.35
solarDefMaxMaxPVInputVoltThe upper limit of max PV input voltagero
INTEGER
.1.3.6.1.4.1.21111.1.2.9.36
solarDefMinMaxPVInputVoltThe lower limit of max PV input voltagero
INTEGER
.1.3.6.1.4.1.21111.1.2.9.37
solarDefMaxMinPVInputVoltThe upper limit of min PV input voltagero
INTEGER
.1.3.6.1.4.1.21111.1.2.9.38
solarDefMinMinPVInputVoltThe lowest limit of min PV input voltagero
INTEGER
.1.3.6.1.4.1.21111.1.2.9.39
solarDefMaxHighMPPTVoltThe max MPPT high voltagero
INTEGER
.1.3.6.1.4.1.21111.1.2.9.40
solarDefMinHighMPPTVoltThe min MPPT high voltagero
INTEGER
.1.3.6.1.4.1.21111.1.2.9.41
solarDefMaxLowMPPTVoltThe max MPPT low voltagero
INTEGER
.1.3.6.1.4.1.21111.1.2.9.42
solarDefMinLowMPPTVoltThe min MPPT low voltagero
INTEGER
.1.3.6.1.4.1.21111.1.2.9.43
solarDefMaxOutputPowerThe max output powerro
INTEGER
.1.3.6.1.4.1.21111.1.2.9.44
solarDefMinOutputPowerThe min output powerro
INTEGER
.1.3.6.1.4.1.21111.1.2.9.45
solarDefMaxRChargVoltThe min charging voltagero
INTEGER
.1.3.6.1.4.1.21111.1.2.9.46
solarDefMinRChargVoltThe max charging voltagero
INTEGER
.1.3.6.1.4.1.21111.1.2.9.47
solarFaultInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.2.10
solarFaultCurrentIDcurrent fault ID.ro
INTEGER
.1.3.6.1.4.1.21111.1.2.10.1
solarFaultQueryFaultIDquery fault ID.rw
INTEGER
.1.3.6.1.4.1.21111.1.2.10.2
solarFaultQueryResultQuery fault info result.ro
Enumeration
.1.3.6.1.4.1.21111.1.2.10.3
solarFaultFaultKindDevice Fault kind.ro
DisplayString
.1.3.6.1.4.1.21111.1.2.10.4
solarFaultFaultTimeDevice Fault time.format is YYYYMMDDHHMMSSro
DisplayString
.1.3.6.1.4.1.21111.1.2.10.5
solarFaultPVStatusPV running status before fault. b31-b16:reserved b15 : PV1 boost on b14 : PV2 boost on b13 : PV3 boost on b12 : Inverter on b11 : 1: PV1 MPPT by boost; 0: PV1 MPPT by inverter b10 : 1: PV2 MPPT by boost; 0: PV2 MPPT by inverter b9 : 1: PV3 MPPT by boost; 0: PV3 MPPT by inverter b8 : O/P relay on b7 : Inverter relay on b6 : Safe relay on b5 : Main relay on b4 : AC relay on b3 : Reserved b2 : Reserved b1 : Reserved b0 : DC TO DC onro
NonNegativeInteger (UPS-MIB)
.1.3.6.1.4.1.21111.1.2.10.6
solarFaultTemperatureMax Temperature of the detecting pointers before fault.ro
INTEGER UNITS "degrees 0.1 Centigrade"
.1.3.6.1.4.1.21111.1.2.10.7
solarFaultBattVoltBattery voltage before fault.ro
NonNegativeInteger UNITS "0.1 Volt DC"
.1.3.6.1.4.1.21111.1.2.10.8
solarFaultPV1VoltagePV1 input voltage before fault.ro
INTEGER UNITS "0.1 Volts"
.1.3.6.1.4.1.21111.1.2.10.9
solarFaultPV1CurrentPV1 current before fault.ro
INTEGER UNITS "0.1 A"
.1.3.6.1.4.1.21111.1.2.10.10
solarFaultPV2VoltagePV2 input voltage before fault.ro
INTEGER UNITS "0.1 Volts"
.1.3.6.1.4.1.21111.1.2.10.11
solarFaultPV2CurrentPV2 current before fault.ro
INTEGER UNITS "0.1 A"
.1.3.6.1.4.1.21111.1.2.10.12
solarFaultPV3VoltagePV3 input voltage before fault.ro
INTEGER UNITS "0.1 Volts"
.1.3.6.1.4.1.21111.1.2.10.13
solarFaultPV3CurrentPV3 current before fault.ro
INTEGER UNITS "0.1 A"
.1.3.6.1.4.1.21111.1.2.10.14
solarFaultNumLinesAC output,Grid and Inverter lines number.ro
NonNegativeInteger (UPS-MIB)
.1.3.6.1.4.1.21111.1.2.10.15
solarFaultGridFrequencyGrid frequency before fault.ro
NonNegativeInteger UNITS "0.1Hz"
.1.3.6.1.4.1.21111.1.2.10.16
solarFaultACOutFrequencyAC output Frequency before fault.ro
NonNegativeInteger UNITS "0.1Hz"
.1.3.6.1.4.1.21111.1.2.10.17
solarFaultLoadPercentOutput load percentage before fault.ro
NonNegativeInteger UNITS "%"
.1.3.6.1.4.1.21111.1.2.10.18
solarFaultTableA list of fault table entries. The number of entries is given by the value of solarFault NumLines.
SEQUENCE OF SolarFaultEntry
.1.3.6.1.4.1.21111.1.2.10.19
solarFaultEntryAn entry containing information applicable to a particular input line.
SolarFaultEntry
.1.3.6.1.4.1.21111.1.2.10.19.1
solarFaultLineIndexThe number of inverter,grid and ACOutput line identifier.ro
INTEGER
.1.3.6.1.4.1.21111.1.2.10.19.1.1
solarFaultInverterVoltInverter voltage before fault.ro
INTEGER UNITS "0.1Volt"
.1.3.6.1.4.1.21111.1.2.10.19.1.2
solarFaultInverterCurrInverter current before fault.ro
INTEGER UNITS "0.1A"
.1.3.6.1.4.1.21111.1.2.10.19.1.3
solarFaultGridVoltageGrid voltage before fault.ro
INTEGER UNITS "0.1Volt"
.1.3.6.1.4.1.21111.1.2.10.19.1.4
solarFaultGridCurrentGrid current before fault.ro
INTEGER UNITS "0.1A"
.1.3.6.1.4.1.21111.1.2.10.19.1.5
solarFaultACOutputVoltAC output voltage before fault.ro
INTEGER UNITS "0.1Volt"
.1.3.6.1.4.1.21111.1.2.10.19.1.6
solarFaultACOutputCurrAC output current before fault.ro
INTEGER UNITS "0.1A"
.1.3.6.1.4.1.21111.1.2.10.19.1.7
solarControl
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.2.11
solarCtlFeedGridSetting this object to turn feeding grid enable(1) or disable(2)rw
Enumeration
.1.3.6.1.4.1.21111.1.2.11.1
solarAgentConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.2.12
solarAgentDatetimeThe datetime in agent, format is (MM/DD/YYYY hh:mm:ss)rw
DisplayString
.1.3.6.1.4.1.21111.1.2.12.1
solarCommConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.2.13
solarCommBaudRateThe solar inverter communicate baudraterw
Enumeration
.1.3.6.1.4.1.21111.1.2.13.1
solarCommDatabitsThe solar inverter communicate data bitsrw
INTEGER
.1.3.6.1.4.1.21111.1.2.13.2
solarCommStopbitsThe solar inverter communicate stop bitsrw
INTEGER
.1.3.6.1.4.1.21111.1.2.13.3
solarCommParityThe solar inverter communicate Parityrw
Enumeration
.1.3.6.1.4.1.21111.1.2.13.4
solarCommTimeoutThe solar inverter communicate timeoutrw
INTEGER
.1.3.6.1.4.1.21111.1.2.13.5
solarConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.2.14
solarCfgGridOutVolHLossgrid output voltage high loss pointrw
INTEGER
.1.3.6.1.4.1.21111.1.2.14.1
solarCfgGridOutVolLLossgrid output voltage low loss pointrw
INTEGER
.1.3.6.1.4.1.21111.1.2.14.2
solarCfgGridOutFreqHLossgrid output frequency high loss pointrw
INTEGER --(501..548,602..648) UNITS "0.1 Hertz "
.1.3.6.1.4.1.21111.1.2.14.3
solarCfgGridOutFreqLLossgrid output frequency low loss pointrw
INTEGER --(450..498,550..598) UNITS "0.1 Hertz "
.1.3.6.1.4.1.21111.1.2.14.4
solarCfgCurrentMaxOutPowerthe max output power. ener solar:0-030000rw
INTEGER
.1.3.6.1.4.1.21111.1.2.14.5
solarCfgPVHVolMPPTthe PV input high voltage for MPPTrw
INTEGER
.1.3.6.1.4.1.21111.1.2.14.6
solarCfgPVLVolMPPTSet the PV input low voltage for MPPTrw
INTEGER
.1.3.6.1.4.1.21111.1.2.14.7
solarCfgUpLimitPVVolSet the upper limit of PV input voltagerw
INTEGER
.1.3.6.1.4.1.21111.1.2.14.8
solarCfgLowLimitPVVolSet the lowest limit of PV input voltagerw
INTEGER
.1.3.6.1.4.1.21111.1.2.14.9
solarCfgLCDSleepTimeSetting LCD sleep time,0 means always light, the unit is 30s.rw
Enumeration
.1.3.6.1.4.1.21111.1.2.14.10
solarCfgGridInVolHLossSet grid input voltage high loss pointrw
INTEGER
.1.3.6.1.4.1.21111.1.2.14.11
solarCfgGridInVolLLossSet grid input voltage low loss pointrw
INTEGER
.1.3.6.1.4.1.21111.1.2.14.12
solarCfgGridInFreqHLossgrid input frequency high loss pointrw
INTEGER --(510..600,610..700) UNITS "0.1Hz"
.1.3.6.1.4.1.21111.1.2.14.13
solarCfgGridInFreqLLossgrid input frequency low loss pointrw
INTEGER --(400..490,500..590) UNITS "0.1Hz"
.1.3.6.1.4.1.21111.1.2.14.14
solarCfgAverageVolHLossthe grid long time average voltage high loss pointrw
INTEGER
.1.3.6.1.4.1.21111.1.2.14.15
solarCfgAverageVolLLossthe grid long time average voltage low loss pointrw
INTEGER
.1.3.6.1.4.1.21111.1.2.14.16
solarCfgSetDefaultValueSetting control parsameter to default valuserw
Enumeration
.1.3.6.1.4.1.21111.1.2.14.17
solarCfgWaiteTimeFeedSetting waiting time for feedingrw
INTEGER
.1.3.6.1.4.1.21111.1.2.14.18
solarCfgSilenceBuzzerSetting this object to Enable/disable silence buzzer or open buzzerrw
Enumeration
.1.3.6.1.4.1.21111.1.2.14.19
solarCfgBuzzerInStandbySetting this object to Enable/disable buzzer audible in standby moderw
Enumeration
.1.3.6.1.4.1.21111.1.2.14.20
solarCfgAutoRestartEnable/disable auto-Restart. (for hybrid)rw
Enumeration
.1.3.6.1.4.1.21111.1.2.14.21
solarCfgBatMAudibleWarnEnable/disable battery mode audible warning (for hybrid)rw
Enumeration
.1.3.6.1.4.1.21111.1.2.14.22
solarCfgBatOpenCheckEnable/disable battery open status check (for hybrid)rw
Enumeration
.1.3.6.1.4.1.21111.1.2.14.23
solarCfgSiteFaultDetectEnable/disable Site fault detect (for hybrid)rw
Enumeration
.1.3.6.1.4.1.21111.1.2.14.24
solarCfgHotStandbyMSHot standby master/slave PEM means master, PDM means slave (for hybrid)rw
Enumeration
.1.3.6.1.4.1.21111.1.2.14.25
solarCfgBatDpDischgProtEnable/disable battery deep discharge protect (for hybrid)rw
Enumeration
.1.3.6.1.4.1.21111.1.2.14.26
solarCfgBatLowDischgProtEnable/disable battery low protect (if disable, the battery will discharge to 6V) (for hybrid)rw
Enumeration
.1.3.6.1.4.1.21111.1.2.14.27
solarCfgCodeStartEnable/disable code start (for hybrid)rw
Enumeration
.1.3.6.1.4.1.21111.1.2.14.28
solarCfgBypassForbidEnable/disable bypass forbidding (for hybrid)rw
Enumeration
.1.3.6.1.4.1.21111.1.2.14.29
solarCfgBypassWhenOffEnable/disable bypass when device turn off. (for hybrid)rw
Enumeration
.1.3.6.1.4.1.21111.1.2.14.30
solarCfgShortRestart3Enable/disable short restart 3 times (for hybrid)rw
Enumeration
.1.3.6.1.4.1.21111.1.2.14.31
solarCfgShortClearEnable/disable inverter short clear function (for hybrid)rw
Enumeration
.1.3.6.1.4.1.21111.1.2.14.32
solarCfgMaxChargeVolMax floating charging voltage (for hybrid)rw
INTEGER
.1.3.6.1.4.1.21111.1.2.14.33
solarCfgMaxChargeCurrMax floating charging current (for hybrid)rw
INTEGER
.1.3.6.1.4.1.21111.1.2.14.34
solarCfgChargingEnableEnable/disable charging on grid mode (for hybrid)rw
Enumeration
.1.3.6.1.4.1.21111.1.2.14.35
solarTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.2.15
cmpPVFailurePV fail
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.1
cmpAutoAdjustFailureAuto adjust processing
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.2
cmpExFlashFailureExternal flash fail
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.3
cmpPVLossFailurePV loss
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.4
cmpPVLowFailurePV low
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.5
cmpLandingFailureIslanding detect
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.6
cmpInitialFailureInitial fail
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.7
cmpGridVolHLossFailureGrid voltage high loss
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.8
cmpGridVolLLossFailureGrid voltage low loss
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.9
cmpGridFreqHLossFailureGrid frequency high loss
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.10
cmpGridFreqLLossFailureGrid frequency low loss
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.11
cmpFeedVolOverFailureFeeding average voltage over
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.12
cmpGetEnergyFGridWarnget energy from the grid
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.13
cmpEPOActiveWarnEPO active
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.14
cmpBusOverVolFailBus over voltage
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.15
cmpBusUnderVolFailBus under voltage
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.16
cmpBusSoftStartTimeOutBus soft start time out
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.17
cmpInverterStartTimeOutInverter soft start time out
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.18
cmpInverterShortInverter short
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.19
cmpPVOverTemperatureOver temperature
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.20
cmpPVRelayFaultRelay fault
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.21
cmpDCCurrentFailDC current fail
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.22
cmpPVHighVolFailPV high voltage
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.23
cmpPVPowerDownPower down
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.24
cmpPVInputShortFailPV input short
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.25
cmpPVGFCIOverFailGFCI over
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.26
cmpPVIsolationLowPV isolation low
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.27
cmpInverterDCCurrOverInverter DC current over
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.28
cmpMCUDSPLineFailLine value consistent fail between MCU & DSP
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.29
cmpPVGFCISensorFailGFCI sensor fail
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.30
cmpMCUDSPConnectFailConnect fail between MCU & DSP
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.31
cmpMCUDSPCommuicateFailCommunication fail between MCU & DSP
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.32
cmpPVGroundLossFailGround loss
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.33
cmpPVPowerOnModePower On Mode
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.34
cmpPVStandbyModeStandby Mode
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.35
cmpPVBypassModeBypass Mode
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.36
cmpPVLineModeLine Mode
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.37
cmpPVBatteryModeBattery Mode
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.38
cmpPVBatteryTestModeBattery Test Mode
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.39
cmpPVFaultModeFault Mode
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.40
cmpPVShutdownModeShutdown Mode
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.41
cmpPVGridModeGrid mode
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.42
cmpPVOtherModeother solar inverter mode
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.43
cmpPVChargeModeCharge mode
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.44
cmpPVBatteryUnderBattery under
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.45
cmpPVBatteryLowBattery low
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.46
cmpPVBatteryOpenBattery open
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.47
cmpPVBatDischatgeLowBattery discharge low
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.48
cmpPVOverLowOver low
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.49
cmpPVChAbnormal1EMD Channels 1 Abnormal
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.130
cmpPVChAbnormal2EMD Channels 2 Abnormal
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.131
cmpPVChAbnormal3EMD Channels 3 Abnormal
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.132
cmpPVChAbnormal4EMD Channels 4 Abnormal
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.133
cmpPVChAbnormal5EMD Channels 5 Abnormal: smoke alarm
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.134
cmpPVChAbnormal6EMD Channels 6 Abnormal
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.135
cmpPVChAbnormal7EMD Channels 7 Abnormal
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.136
cmpPVChAbnormal8EMD Channels 8 Abnormal
TRAP-TYPE
.1.3.6.1.4.1.21111.1.2.15.0.137
solartrapfaultnodev1v2The share trap-node for send fault traps
INTEGER
.1.3.6.1.4.1.21111.1.2.15.998
solartrapleafnodev1v2The share trap-node for send all warn traps
DisplayString
.1.3.6.1.4.1.21111.1.2.15.999
solarExtend
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.2.16
solarExWorkTemperatureThe temperature of work environmentro
INTEGER (-2200..2200) UNITS "degrees 0.1 Centigrade"
.1.3.6.1.4.1.21111.1.2.16.1
solarExWorkhumidityThe humidity of work environmentro
INTEGER
.1.3.6.1.4.1.21111.1.2.16.2
solarExSmokeScopeThe smokeScope of work environmentro
INTEGER
.1.3.6.1.4.1.21111.1.2.16.3
solarExEMDAlarm1Environment detector alarm 1ro
Enumeration
.1.3.6.1.4.1.21111.1.2.16.4
solarExEMDAlarm2Environment detector alarm 2ro
Enumeration
.1.3.6.1.4.1.21111.1.2.16.5
solarExEMDAlarm3Environment detector alarm 3ro
Enumeration
.1.3.6.1.4.1.21111.1.2.16.6
solarExEMDAlarm4Environment detector alarm 4ro
Enumeration
.1.3.6.1.4.1.21111.1.2.16.7
charger
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.3
ats
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.4
atsIdent
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.4.1
atsIdManufacturerThe name of the solar manufacturer.ro
DisplayString
.1.3.6.1.4.1.21111.1.4.1.1
atsIdProtocolThe solar Protocol id.ro
Enumeration
.1.3.6.1.4.1.21111.1.4.1.2
atsIdModelNameThe ats Model designation.ro
DisplayString
.1.3.6.1.4.1.21111.1.4.1.3
atsIdSerialNumberThe ats serial no.ro
DisplayString
.1.3.6.1.4.1.21111.1.4.1.4
atsIdNameA string identifying the ats. This object should be set by the administrator.rw
DisplayString
.1.3.6.1.4.1.21111.1.4.1.5
atsIdFWVersionMain CPU firmware version.ro
DisplayString
.1.3.6.1.4.1.21111.1.4.1.6
atsIdatsTypeats type.ro
Enumeration
.1.3.6.1.4.1.21111.1.4.1.7
atsRating
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.4.2
atsRatOutVoltageThe rating output voltage of atsro
NonNegativeInteger UNITS "0.1 vol"
.1.3.6.1.4.1.21111.1.4.2.1
atsRatOutCurrentThe rating output current of atsro
NonNegativeInteger UNITS "0.1 A"
.1.3.6.1.4.1.21111.1.4.2.2
atsRatOutFrequencyThe rating output frequency of atsro
NonNegativeInteger UNITS "0.1 Hz"
.1.3.6.1.4.1.21111.1.4.2.3
atsInformation
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.4.3
atsInfoSource1InVolThe source 1 input voltage of atsro
NonNegativeInteger UNITS "0.1 vol"
.1.3.6.1.4.1.21111.1.4.3.1
atsInfoSource1FreqThe source 1 frequency of atsro
NonNegativeInteger UNITS "0.1 Hz"
.1.3.6.1.4.1.21111.1.4.3.2
atsInfoSource2InVolThe source 2 input voltage of atsro
NonNegativeInteger UNITS "0.1 vol"
.1.3.6.1.4.1.21111.1.4.3.3
atsInfoSource2FreqThe source 2 frequency of atsro
NonNegativeInteger UNITS "0.1 Hz"
.1.3.6.1.4.1.21111.1.4.3.4
atsInfoOutputLoadLoad percentagero
INTEGER
.1.3.6.1.4.1.21111.1.4.3.5
atsInfoOutputCurrentThe output current of the ats systemro
INTEGER UNITS "0.1 Amp"
.1.3.6.1.4.1.21111.1.4.3.6
atsInfoSynchronAngleThe Synchron Angle of the ats systemro
INTEGER UNITS ""
.1.3.6.1.4.1.21111.1.4.3.7
atsInfoTemperatureThe Internal temperature of the ats systemro
INTEGER UNITS "degrees 0.1 Centigrade"
.1.3.6.1.4.1.21111.1.4.3.8
atsControl
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.4.4
atsAgentConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.4.5
atsAgentDatetimeThe datetime in agent, format is (MM/DD/YYYY hh:mm:ss)rw
DisplayString
.1.3.6.1.4.1.21111.1.4.5.1
atsCommConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.4.6
atsCommBaudRateThe ats communicate baudraterw
Enumeration
.1.3.6.1.4.1.21111.1.4.6.1
atsCommDatabitsThe ats communicate data bitsrw
INTEGER
.1.3.6.1.4.1.21111.1.4.6.2
atsCommStopbitsThe ats communicate stop bitsrw
INTEGER
.1.3.6.1.4.1.21111.1.4.6.3
atsCommParityThe ats communicate Parityrw
Enumeration
.1.3.6.1.4.1.21111.1.4.6.4
atsCommTimeoutThe ats communicate timeoutrw
INTEGER
.1.3.6.1.4.1.21111.1.4.6.5
atsConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.4.7
atsCfgSource1VolHLossSet source1 voltage high lossrw
INTEGER
.1.3.6.1.4.1.21111.1.4.7.1
atsCfgSource1VolHBackSet source1 voltage high backrw
INTEGER
.1.3.6.1.4.1.21111.1.4.7.2
atsCfgSource1VolLLossSet source1 voltage low lossrw
INTEGER
.1.3.6.1.4.1.21111.1.4.7.3
atsCfgSource1VolLBackSet source1 voltage low backrw
INTEGER
.1.3.6.1.4.1.21111.1.4.7.4
atsCfgSource1FreqHLossSet source1 frequency high lossrw
INTEGER
.1.3.6.1.4.1.21111.1.4.7.5
atsCfgSource1FreqHBackSet source1 frequency high backrw
INTEGER
.1.3.6.1.4.1.21111.1.4.7.6
atsCfgSource1FreqLLossSet source1 frequency low lossrw
INTEGER
.1.3.6.1.4.1.21111.1.4.7.7
atsCfgSource1FreqLBackSet source1 frequency low backrw
INTEGER
.1.3.6.1.4.1.21111.1.4.7.8
atsCfgSource2VolHLossSet source2 voltage high lossrw
INTEGER
.1.3.6.1.4.1.21111.1.4.7.9
atsCfgSource2VolHBackSet source2 voltage high backrw
INTEGER
.1.3.6.1.4.1.21111.1.4.7.10
atsCfgSource2VolLLossSet source2 voltage low lossrw
INTEGER
.1.3.6.1.4.1.21111.1.4.7.11
atsCfgSource2VolLBackSet source2 voltage low backrw
INTEGER
.1.3.6.1.4.1.21111.1.4.7.12
atsCfgSource2FreqHLossSet source2 frequency high lossrw
INTEGER
.1.3.6.1.4.1.21111.1.4.7.13
atsCfgSource2FreqHBackSet source2 frequency high backrw
INTEGER
.1.3.6.1.4.1.21111.1.4.7.14
atsCfgSource2FreqLLossSet source2 frequency low lossrw
INTEGER
.1.3.6.1.4.1.21111.1.4.7.15
atsCfgSource2FreqLBackSet source2 frequency low backrw
INTEGER
.1.3.6.1.4.1.21111.1.4.7.16
atsCfgOverLoadAlarmPointSet over load alarm pointrw
INTEGER
.1.3.6.1.4.1.21111.1.4.7.17
atsCfgOverLoadFaultPointSet over load fault pointrw
INTEGER
.1.3.6.1.4.1.21111.1.4.7.18
atsCfgAcceptablePhasesSet acceptable phasesrw
INTEGER
.1.3.6.1.4.1.21111.1.4.7.19
atsCfgBreakingTimeSet breaking timerw
INTEGER
.1.3.6.1.4.1.21111.1.4.7.20
atsCfgBlankingTimeSet blanking timerw
INTEGER
.1.3.6.1.4.1.21111.1.4.7.21
atsTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.4.8
cmpatsSourceS1VolBadSource S1 Voltage rms bad
TRAP-TYPE
.1.3.6.1.4.1.21111.1.4.8.0.1
cmpatsSourceS1FreqBadSource S1 frequency bad
TRAP-TYPE
.1.3.6.1.4.1.21111.1.4.8.0.2
cmpatsSourceS1WaveBadSource S1 wave bad
TRAP-TYPE
.1.3.6.1.4.1.21111.1.4.8.0.3
cmpatsSourceS2VolBadSource S2 Voltage rms bad
TRAP-TYPE
.1.3.6.1.4.1.21111.1.4.8.0.4
cmpatsSourceS2FreqBadSource S2 frequency bad
TRAP-TYPE
.1.3.6.1.4.1.21111.1.4.8.0.5
cmpatsSourceS2WaveBadSource S2 wave bad
TRAP-TYPE
.1.3.6.1.4.1.21111.1.4.8.0.6
cmpatsOnSourceS2On Source S2
TRAP-TYPE
.1.3.6.1.4.1.21111.1.4.8.0.7
cmpatsOnSourceS1On Source S1
TRAP-TYPE
.1.3.6.1.4.1.21111.1.4.8.0.8
cmpatsSourceS2PreferredSource S2 Preferred Source
TRAP-TYPE
.1.3.6.1.4.1.21111.1.4.8.0.9
cmpatsSynchronBadSynchron bad
TRAP-TYPE
.1.3.6.1.4.1.21111.1.4.8.0.10
cmpatsAuxPower1FailAux. Power1 failure
TRAP-TYPE
.1.3.6.1.4.1.21111.1.4.8.0.11
cmpatsAuxPower2FailAux. Power2 failure
TRAP-TYPE
.1.3.6.1.4.1.21111.1.4.8.0.12
cmpatsShortFaultShort fault
TRAP-TYPE
.1.3.6.1.4.1.21111.1.4.8.0.13
cmpatsOverloadFaultOverload fault
TRAP-TYPE
.1.3.6.1.4.1.21111.1.4.8.0.14
cmpatsOverloadAlarmOverload Alarm
TRAP-TYPE
.1.3.6.1.4.1.21111.1.4.8.0.15
cmpatsOnFaultModeOn fault mode
TRAP-TYPE
.1.3.6.1.4.1.21111.1.4.8.0.16
cmpatsChAbnormal1EMD Channels 1 Abnormal
TRAP-TYPE
.1.3.6.1.4.1.21111.1.4.8.0.130
cmpatsChAbnormal2EMD Channels 2 Abnormal
TRAP-TYPE
.1.3.6.1.4.1.21111.1.4.8.0.131
cmpatsChAbnormal3EMD Channels 3 Abnormal
TRAP-TYPE
.1.3.6.1.4.1.21111.1.4.8.0.132
cmpatsChAbnormal4EMD Channels 4 Abnormal
TRAP-TYPE
.1.3.6.1.4.1.21111.1.4.8.0.133
cmpatsChAbnormal5EMD Channels 5 Abnormal: smoke alarm
TRAP-TYPE
.1.3.6.1.4.1.21111.1.4.8.0.134
cmpatsChAbnormal6EMD Channels 6 Abnormal
TRAP-TYPE
.1.3.6.1.4.1.21111.1.4.8.0.135
cmpatsChAbnormal7EMD Channels 7 Abnormal
TRAP-TYPE
.1.3.6.1.4.1.21111.1.4.8.0.136
cmpatsChAbnormal8EMD Channels 8 Abnormal
TRAP-TYPE
.1.3.6.1.4.1.21111.1.4.8.0.137
atstrapleafnodev1v2The share trap-node for send all traps
INTEGER
.1.3.6.1.4.1.21111.1.4.8.999
atsExtend
OBJECT IDENTIFIER
.1.3.6.1.4.1.21111.1.4.9
atsExWorkTemperatureThe temperature of work environmentro
INTEGER (-2200..2200) UNITS "degrees 0.1 Centigrade"
.1.3.6.1.4.1.21111.1.4.9.1
atsExWorkhumidityThe humidity of work environmentro
INTEGER
.1.3.6.1.4.1.21111.1.4.9.2
atsExSmokeScopeThe smokeScope of work environmentro
INTEGER
.1.3.6.1.4.1.21111.1.4.9.3
atsExEMDAlarm1Environment detector alarm 1ro
Enumeration
.1.3.6.1.4.1.21111.1.4.9.4
atsExEMDAlarm2Environment detector alarm 2ro
Enumeration
.1.3.6.1.4.1.21111.1.4.9.5
atsExEMDAlarm3Environment detector alarm 3ro
Enumeration
.1.3.6.1.4.1.21111.1.4.9.6
atsExEMDAlarm4Environment detector alarm 4ro
Enumeration
.1.3.6.1.4.1.21111.1.4.9.7
NextUPSSystems - SNMP MIB Reference | MIBs Explorer