UBQS-SYSTEM-MIB
The UBQS-SYSTEM-MIB module provides SNMP access to fundamental system-level attributes for Ubiquiti Networks (UBNT) devices, specifically exposing standard ISO/IEC 11801-compliant objects such as system description, hardware model, firmware version, uptime, and contact information. This module enables centralized monitoring of device identity and operational status across Ubiquiti infrastructure without requiring vendor-specific proprietary extensions.
Imported Objects
Objects
62 total| Object Name |
|---|
ubiSystemMIBThe UBQS-SYSTEM-MIB is used to get
the system information. MODULE-IDENTITY .1.3.6.1.4.1.7800.100.1 |
RFC1155-SMIThe UBQS-SYSTEM-MIB is used to get
the system information. Unknown .1.3.6.1.4.1.7800.100.1 |
ubiSystemMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.7800.100.1.1 |
ubiSysResetReset the system.rw Enumeration .1.3.6.1.4.1.7800.100.1.1.1 |
ubiSysInfo OBJECT IDENTIFIER .1.3.6.1.4.1.7800.100.1.1.2 |
ubiSysModelThe object identifier for the manufacturer model.ro OBJECT IDENTIFIER .1.3.6.1.4.1.7800.100.1.1.2.1 |
ubiHwVersionHardware version of the system.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.7800.100.1.1.2.2 |
ubiSwVersionSoftware version of the system.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.7800.100.1.1.2.3 |
ubiReleaseDateThe date of release for system OS.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.7800.100.1.1.2.4 |
ubiSerialNumberSerial number of the system.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.7800.100.1.1.2.5 |
ubiSysPhysAddressSystem mac addressro PhysAddress (SNMPv2-TC) .1.3.6.1.4.1.7800.100.1.1.2.6 |
ubiSysClockCurrent local time of the system.
Clock SET:
HH:MM:SS - Current Time
<1-31> - Day of the month
MONTH - Month of the year (First three letters of the month)
<1993-2035> - Year
SET Example
13:10:00 3 Jan 2010rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.7800.100.1.1.2.7 |
ubiSysTimeZone OBJECT IDENTIFIER .1.3.6.1.4.1.7800.100.1.1.2.8 |
ubiSysTimeZoneNameSystem timezone name.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.7800.100.1.1.2.8.1 |
ubiSysTimeZoneOffsetSystem timezone offset(Hours:Minutes).rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.7800.100.1.1.2.8.2 |
ubiSysBanner OBJECT IDENTIFIER .1.3.6.1.4.1.7800.100.1.1.2.9 |
ubiSysBannerLoginnull string -> no banner login
'default' -> banner login default
STRING -> banner login WORDrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.7800.100.1.1.2.9.1 |
ubiSysBannerMotdnull string -> no banner motd
'default' -> banner motd default
STRING -> banner motd WORDrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.7800.100.1.1.2.9.2 |
ubiShelfPhysAddressSystem shelf mac address.ro PhysAddress (SNMPv2-TC) .1.3.6.1.4.1.7800.100.1.1.2.10 |
ubiBspVersionSystem Bsp Versoin.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.7800.100.1.1.2.11 |
ubiSysResetReasonSystem Reset Reason.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.7800.100.1.1.2.12 |
ubiSysLedTest OBJECT IDENTIFIER .1.3.6.1.4.1.7800.100.1.1.6 |
ubiLedTestTimeoutThe timeout to terminate the LED Test.
If the timeout is zero, that is set to default.rw Integer32 .1.3.6.1.4.1.7800.100.1.1.6.1 |
ubiLedTestTriggerTrigger and stop the LED Test.rw Enumeration .1.3.6.1.4.1.7800.100.1.1.6.2 |
ubiLedTestSlotIdLED test Slot idrw Integer32 .1.3.6.1.4.1.7800.100.1.1.6.3 |
ubiSysRedundancy OBJECT IDENTIFIER .1.3.6.1.4.1.7800.100.1.1.7 |
ubiSysRedundancyInfoTableTable of redundancy information SEQUENCE OF UbiSysRedundancyInfoEntry .1.3.6.1.4.1.7800.100.1.1.7.1 |
ubiSysRedundancyInfoEntryEntry of redundancy information UbiSysRedundancyInfoEntry .1.3.6.1.4.1.7800.100.1.1.7.1.1 |
ubiSCURedundancyRoleSCU rolero Enumeration .1.3.6.1.4.1.7800.100.1.1.7.1.1.1 |
ubiSCUPositionSCU postionro Enumeration .1.3.6.1.4.1.7800.100.1.1.7.1.1.2 |
ubiSCUMngLinkStatusmng port status of SCUro Enumeration .1.3.6.1.4.1.7800.100.1.1.7.1.1.3 |
ubiSCUIpAddressIP address of SCUro IpAddress .1.3.6.1.4.1.7800.100.1.1.7.1.1.4 |
ubiSCUPeerEquipStatusPeer Equip status of SCUro Enumeration .1.3.6.1.4.1.7800.100.1.1.7.1.1.5 |
ubiSysRedundancyReloadReload Active and/or Standbyrw Enumeration .1.3.6.1.4.1.7800.100.1.1.7.2 |
ubiSysRedundancyPeerImagePeer boot imagerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.7800.100.1.1.7.3 |
ubiSysBarCode OBJECT IDENTIFIER .1.3.6.1.4.1.7800.100.1.1.8 |
ubiSysBarcodeSystem OBJECT IDENTIFIER .1.3.6.1.4.1.7800.100.1.1.8.1 |
ubiSysBarcodeSystemStringThe textual barcode of system.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.7800.100.1.1.8.1.1 |
ubiSysBarcodePowerTableThis table contains information
for power barcode. SEQUENCE OF UbiSysBarcodePowerEntry .1.3.6.1.4.1.7800.100.1.1.8.2 |
ubiSysBarcodePowerEntryBarcode Information about the power. UbiSysBarcodePowerEntry .1.3.6.1.4.1.7800.100.1.1.8.2.1 |
ubiSysBarcodePowerIndexA unique value for each power entityro INTEGER .1.3.6.1.4.1.7800.100.1.1.8.2.1.1 |
ubiSysBarcodePowerStringThe textual barcode of power entityro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.7800.100.1.1.8.2.1.2 |
ubiSysBarcodeFanTableThis table contains information
for fan barcode. SEQUENCE OF UbiSysBarcodeFanEntry .1.3.6.1.4.1.7800.100.1.1.8.3 |
ubiSysBarcodeFanEntryBarcode Information about the fan UbiSysBarcodeFanEntry .1.3.6.1.4.1.7800.100.1.1.8.3.1 |
ubiSysBarcodeFanIndexA unique value for each fan entityro INTEGER .1.3.6.1.4.1.7800.100.1.1.8.3.1.1 |
ubiSysBarcodeFanStringThe textual barcode of fan entity.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.7800.100.1.1.8.3.1.2 |
ubiSysBarcodeUplinkTableThis table contains information
for uplink module's barcode. SEQUENCE OF UbiSysBarcodeUplinkEntry .1.3.6.1.4.1.7800.100.1.1.8.4 |
ubiSysBarcodeUplinkEntryBarcode Information about the uplink module. UbiSysBarcodeUplinkEntry .1.3.6.1.4.1.7800.100.1.1.8.4.1 |
ubiSysBarcodeUplinkIndexA unique value for each uplink module.ro INTEGER .1.3.6.1.4.1.7800.100.1.1.8.4.1.1 |
ubiSysBarcodeUplinkStringThe textual barcode of uplink module.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.7800.100.1.1.8.4.1.2 |
ubiSysBarcodeSlotTableThis table contains information
for slot's barcode. SEQUENCE OF UbiSysBarcodeSlotEntry .1.3.6.1.4.1.7800.100.1.1.8.5 |
ubiSysBarcodeSlotEntryBarcode Information about the slot. UbiSysBarcodeSlotEntry .1.3.6.1.4.1.7800.100.1.1.8.5.1 |
ubiSysBarcodeSlotIndexA unique value for each slot.ro INTEGER .1.3.6.1.4.1.7800.100.1.1.8.5.1.1 |
ubiSysBarcodeSlotStringThe textual barcode of slot.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.7800.100.1.1.8.5.1.2 |
ubiSysBarcodeScuTableThis table contains information
for SCU's barcode. SEQUENCE OF UbiSysBarcodeScuEntry .1.3.6.1.4.1.7800.100.1.1.8.6 |
ubiSysBarcodeScuEntryBarcode Information about the SCU. UbiSysBarcodeScuEntry .1.3.6.1.4.1.7800.100.1.1.8.6.1 |
ubiSysBarcodeScuIndexA unique value for each SCU.ro INTEGER .1.3.6.1.4.1.7800.100.1.1.8.6.1.1 |
ubiSysBarcodeScuStringThe textual barcode of SCU.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.7800.100.1.1.8.6.1.2 |
ubiSystemMIBNotificationPrefix OBJECT IDENTIFIER .1.3.6.1.4.1.7800.100.1.2 |
ubiSystemMIBConformance OBJECT IDENTIFIER .1.3.6.1.4.1.7800.100.1.3 |
ubiSysMIBCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.7800.100.1.3.1 |
ubiSysMIBGroups OBJECT IDENTIFIER .1.3.6.1.4.1.7800.100.1.3.2 |
More MIBs from Ubiquoss
Browse all UbiquossMIBs →The UBIQUOSS-EPON-PON-PROFILE-GROUP-MIB manages Quality of Service (QoS) profile configurations and parameters for EPON (Ethernet Passive Optical Network) PON interfaces on Ubiquoss optical line terminal (OLT) hardware. It enables the definition, monitoring, and enforcement of traffic shaping, priority queuing, and bandwidth allocation policies across specific PON port groups.
The UBIQUOSS-10GEPON-PON-PROFILE-GROUP-MIB manages Quality of Service (QoS) profile configurations and parameters for Ubiquiti 10G-EPON Optical Line Terminals (OLTs). It enables the definition and monitoring of traffic shaping rules, bandwidth limits, and priority queues applied to specific PON profile groups within the access network.
The UBIQUOSS-EPON-PM-GROUP-MIB module enables monitoring of performance metrics for Ubiquiti EPON (Ethernet Passive Optical Network) interfaces, specifically tracking traffic counters, error statistics, and link utilization data for optical line terminals and optical network units.
The UBIQUOSS-EPON-PON-MAC-GROUP-MIB module provides management interfaces for monitoring and configuring MAC-layer parameters, including subscriber MAC addresses, VLAN mappings, and traffic statistics, within Ubiquiti's EPON (Ethernet Passive Optical Network) access network infrastructure.
The UBIQUOSS-10GEPON-PM-GROUP-MIB module enables performance monitoring of Ubiquiti 10G-EPON optical line terminals and optical network units by exposing traffic counters, error statistics, and link utilization metrics. It facilitates the collection of physical layer and data link layer performance data, including bit error rates, packet drops, and interface throughput, for network capacity planning and fault isolation.
The UBIQUOSS-10GEPON-PON-MAC-GROUP-MIB module enables monitoring and management of MAC layer statistics, session states, and interface counters for Ubiquiti 10G Ethernet Passive Optical Network (EPON) optical line terminals and optical network units. It provides specific visibility into 10G-EPON MAC protocol operations, including port status, traffic counters, and subscriber link metrics required for provisioning and fault isolation.