UBNT-UFIBER-MIB
The UBNT-UFIBER-MIB module enables SNMP-based monitoring and management of Ubiquiti EdgeMax fiber optic network entities, specifically exposing performance metrics such as optical power levels, signal attenuation, and link status for fiber transceivers. This module facilitates the tracking of physical layer health and interface statistics essential for maintaining the integrity of Ubiquiti's fiber infrastructure.
Imported Objects
Objects
72 total| Object Name |
|---|
ubntEdgeMax MODULE-IDENTITY .1.3.6.1.4.1.41112.1.5 |
ubntProductIdent OBJECT IDENTIFIER .1.3.6.1.4.1.41112.1.5.1 |
ubntModelro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.41112.1.5.1.1 |
ubntSerialNumberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.41112.1.5.1.2 |
ubntVersionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.41112.1.5.1.3 |
ubntPowerOuts OBJECT IDENTIFIER .1.3.6.1.4.1.41112.1.5.2 |
ubntPowerOutsCountro Unsigned32 .1.3.6.1.4.1.41112.1.5.2.1 |
ubntPowerOutTable SEQUENCE OF UbntPowerOutEntry .1.3.6.1.4.1.41112.1.5.2.2 |
ubntPowerOutEntry UbntPowerOutEntry .1.3.6.1.4.1.41112.1.5.2.2.1 |
ubntPowerOutIndexro Integer32 .1.3.6.1.4.1.41112.1.5.2.2.1.1 |
ubntPowerOutVoltagero Integer32 .1.3.6.1.4.1.41112.1.5.2.2.1.2 |
ubntPowerOutCurrentro Integer32 .1.3.6.1.4.1.41112.1.5.2.2.1.3 |
ubntPowerOutPowerro Integer32 .1.3.6.1.4.1.41112.1.5.2.2.1.4 |
ubntPowerSupplies OBJECT IDENTIFIER .1.3.6.1.4.1.41112.1.5.3 |
ubntPsuBaysNumberro Unsigned32 .1.3.6.1.4.1.41112.1.5.3.1 |
ubntPsuTable SEQUENCE OF UbntPsuEntry .1.3.6.1.4.1.41112.1.5.3.2 |
ubntPsuEntry UbntPsuEntry .1.3.6.1.4.1.41112.1.5.3.2.1 |
ubntPsuIndexro Integer32 .1.3.6.1.4.1.41112.1.5.3.2.1.1 |
ubntPsuTypero Enumeration .1.3.6.1.4.1.41112.1.5.3.2.1.2 |
ubntPsuStatusro Enumeration .1.3.6.1.4.1.41112.1.5.3.2.1.3 |
ubntPsuOperStatusro Enumeration .1.3.6.1.4.1.41112.1.5.3.2.1.4 |
ubntPsuVoltagero Integer32 .1.3.6.1.4.1.41112.1.5.3.2.1.5 |
ubntPsuTemperaturero Integer32 .1.3.6.1.4.1.41112.1.5.3.2.1.6 |
ubntPsuChargingro Enumeration .1.3.6.1.4.1.41112.1.5.3.2.1.7 |
ubntPsuBatteryQuantityro Integer32 .1.3.6.1.4.1.41112.1.5.3.2.1.8 |
ubntThermometers OBJECT IDENTIFIER .1.3.6.1.4.1.41112.1.5.4 |
ubntThermometersCountro Unsigned32 .1.3.6.1.4.1.41112.1.5.4.1 |
ubntThermsTable SEQUENCE OF UbntThermsEntry .1.3.6.1.4.1.41112.1.5.4.2 |
ubntThermsEntry UbntThermsEntry .1.3.6.1.4.1.41112.1.5.4.2.1 |
ubntThermIndexro Integer32 .1.3.6.1.4.1.41112.1.5.4.2.1.1 |
ubntThermTypero Enumeration .1.3.6.1.4.1.41112.1.5.4.2.1.2 |
ubntThermTemperaturero Integer32 .1.3.6.1.4.1.41112.1.5.4.2.1.3 |
ubntFans OBJECT IDENTIFIER .1.3.6.1.4.1.41112.1.5.5 |
ubntFansCountro Unsigned32 .1.3.6.1.4.1.41112.1.5.5.1 |
ubntFansTable SEQUENCE OF UbntFanEntry .1.3.6.1.4.1.41112.1.5.5.2 |
ubntFanEntry UbntFanEntry .1.3.6.1.4.1.41112.1.5.5.2.1 |
ubntFanIndexro Integer32 .1.3.6.1.4.1.41112.1.5.5.2.1.1 |
ubntFanTypero Enumeration .1.3.6.1.4.1.41112.1.5.5.2.1.2 |
ubntFanRpmro Integer32 .1.3.6.1.4.1.41112.1.5.5.2.1.3 |
ubntOnus OBJECT IDENTIFIER .1.3.6.1.4.1.41112.1.5.6 |
ubntOnusCountro Unsigned32 .1.3.6.1.4.1.41112.1.5.6.1 |
ubntOnusTable SEQUENCE OF UbntOnuEntry .1.3.6.1.4.1.41112.1.5.6.2 |
ubntOnuEntry UbntOnuEntry .1.3.6.1.4.1.41112.1.5.6.2.1 |
ubntOnuIndexro Integer32 .1.3.6.1.4.1.41112.1.5.6.2.1.1 |
ubntOnuSNro UbntOnuSN .1.3.6.1.4.1.41112.1.5.6.2.1.1 |
ubntOnuNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.41112.1.5.6.2.1.2 |
ubntOnuOnlinero TruthValue (SNMPv2-TC) .1.3.6.1.4.1.41112.1.5.6.2.1.3 |
ubntOnuModelro DisplayString .1.3.6.1.4.1.41112.1.5.6.2.1.4 |
ubntOnuOltPortro Integer32 .1.3.6.1.4.1.41112.1.5.6.2.1.5 |
ubntOnuConnectedTimero TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.41112.1.5.6.2.1.6 |
ubntOnuUpTimero TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.41112.1.5.6.2.1.7 |
ubntOnuTxPowerro SignalLevel .1.3.6.1.4.1.41112.1.5.6.2.1.8 |
ubntOnuRxPowerro SignalLevel .1.3.6.1.4.1.41112.1.5.6.2.1.9 |
ubntOnuTxBytesro Counter64 .1.3.6.1.4.1.41112.1.5.6.2.1.10 |
ubntOnuRxBytesro Counter64 .1.3.6.1.4.1.41112.1.5.6.2.1.11 |
ubntSfps OBJECT IDENTIFIER .1.3.6.1.4.1.41112.1.5.7 |
ubntSfpsCountro Unsigned32 .1.3.6.1.4.1.41112.1.5.7.1 |
ubntSfpsTable SEQUENCE OF UbntSfpEntry .1.3.6.1.4.1.41112.1.5.7.2 |
ubntSfpEntry UbntSfpEntry .1.3.6.1.4.1.41112.1.5.7.2.1 |
ubntSfpIndexro Integer32 .1.3.6.1.4.1.41112.1.5.7.2.1.1 |
ubntSfpNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.41112.1.5.7.2.1.2 |
ubntSfpUpro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.41112.1.5.7.2.1.3 |
ubntSfpVendorro DisplayString .1.3.6.1.4.1.41112.1.5.7.2.1.4 |
ubntSfpVendorPnro DisplayString .1.3.6.1.4.1.41112.1.5.7.2.1.5 |
ubntSfpTxBytesro Counter64 .1.3.6.1.4.1.41112.1.5.7.2.1.6 |
ubntSfpRxBytesro Counter64 .1.3.6.1.4.1.41112.1.5.7.2.1.7 |
ubntOnuPorts OBJECT IDENTIFIER .1.3.6.1.4.1.41112.1.5.8 |
ubntOnuPortsTable SEQUENCE OF UbntOnuPortEntry .1.3.6.1.4.1.41112.1.5.8.1 |
ubntOnuPortEntry UbntOnuPortEntry .1.3.6.1.4.1.41112.1.5.8.1.1 |
ubntOnuPortSNro UbntOnuSN .1.3.6.1.4.1.41112.1.5.8.1.1.1 |
ubntOnuPortIndexro Integer32 .1.3.6.1.4.1.41112.1.5.8.1.1.2 |
ubntOnuPortIfSpeedro Gauge32 .1.3.6.1.4.1.41112.1.5.8.1.1.3 |
UBNT-UFIBER-MIB Technical Reference Overview
The UBNT-UFIBER-MIB SNMP MIB module published by Ubiquiti defines 72 managed OID objects, including 49 scalar/column metrics, 7 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.41112.1.5. Key tabular structures include ubntPowerOutTable, ubntPsuTable, ubntThermsTable, ubntFansTable, ubntOnusTable, ubntSfpsTable.
Key OID Definitions in UBNT-UFIBER-MIB
.1.3.6.1.4.1.41112.1.5The EdgeMax MIB module for Ubiquiti Networks, Inc. entities
.1.3.6.1.4.1.41112.1.5.2.2A list of power out entries. The number of entries is given by the value of ubntPowerOutsCount.
.1.3.6.1.4.1.41112.1.5.3.2A list of PSU entries. The number of entries is given by the value of ubntPsuBaysNumber.
.1.3.6.1.4.1.41112.1.5.4.2A list of thermometers entries. The number of entries is given by the value of ubntThermometersCount.
.1.3.6.1.4.1.41112.1.5.5.2A list of fan entries. The number of entries is given by the value of ubntFansCount.
.1.3.6.1.4.1.41112.1.5.1.1Product model.
.1.3.6.1.4.1.41112.1.5.1.2Serial number.
.1.3.6.1.4.1.41112.1.5.1.3Firmware version.
.1.3.6.1.4.1.41112.1.5.2.1The number of power outputs present on this system.
.1.3.6.1.4.1.41112.1.5.3.1The number of PSU bays available on this system.
.1.3.6.1.4.1.41112.1.5.4.1The number of installed thermometers on this system.
.1.3.6.1.4.1.41112.1.5.5.1The number of installed fans on this system.
.1.3.6.1.4.1.41112.1.5.7.1The number of SFPs
.1.3.6.1.4.1.41112.1.5.2.2.1An entry in the ubntPowerOutTable.
.1.3.6.1.4.1.41112.1.5.2.2.1.1A unique value for each power output.
.1.3.6.1.4.1.41112.1.5.2.2.1.2Output voltage in mV.
.1.3.6.1.4.1.41112.1.5.2.2.1.3Output current in mA.
.1.3.6.1.4.1.41112.1.5.2.2.1.4Output power in mW.
.1.3.6.1.4.1.41112.1.5.3.2.1An entry in the ubntPsuTable.
.1.3.6.1.4.1.41112.1.5.3.2.1.1A unique value for each PSU.
.1.3.6.1.4.1.41112.1.5.3.2.1.2PSU Type.
.1.3.6.1.4.1.41112.1.5.3.2.1.3PSU Status.
.1.3.6.1.4.1.41112.1.5.3.2.1.4PSU operational status.
.1.3.6.1.4.1.41112.1.5.3.2.1.5PSU voltage in mV.
More MIBs from Ubiquiti
Browse all UbiquitiMIBs →The UBNT-AirFIBER-MIB enables SNMP-based monitoring and management of Ubiquiti AirFIBER point-to-point wireless bridges, exposing critical operational metrics such as link status, signal strength (RSSI), noise floor, transmit power, and interface error counters. This module facilitates the tracking of RF performance parameters and device health statistics essential for maintaining the stability and throughput of long-distance wireless backhaul links.