The UBNT-EdgeMAX-MIB enables SNMP-based monitoring and management of Ubiquiti EdgeMAX series routers and switches, exposing operational metrics such as interface traffic counters, system temperature, CPU utilization, memory usage, and BGP/OSPF routing table states.
Imported Objects
Objects
43 total| Object Name |
|---|
ubntEdgeMaxThe EdgeMax MIB module for Ubiquiti Networks, Inc. entities MODULE-IDENTITY .1.3.6.1.4.1.41112.1.5 |
ubntProductIdent OBJECT IDENTIFIER .1.3.6.1.4.1.41112.1.5.1 |
ubntModelProduct model.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.41112.1.5.1.1 |
ubntSerialNumberSerial number.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.41112.1.5.1.2 |
ubntVersionFirmware version.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.41112.1.5.1.3 |
ubntPowerOuts OBJECT IDENTIFIER .1.3.6.1.4.1.41112.1.5.2 |
ubntPowerOutsCountThe number of power outputs present on this system.ro Unsigned32 .1.3.6.1.4.1.41112.1.5.2.1 |
ubntPowerOutTableA list of power out entries. The number of entries is given by the value of ubntPowerOutsCount. SEQUENCE OF UbntPowerOutEntry .1.3.6.1.4.1.41112.1.5.2.2 |
ubntPowerOutEntryAn entry in the ubntPowerOutTable. UbntPowerOutEntry .1.3.6.1.4.1.41112.1.5.2.2.1 |
ubntPowerOutIndexA unique value for each power output.ro Integer32 .1.3.6.1.4.1.41112.1.5.2.2.1.1 |
ubntPowerOutVoltageOutput voltage in mV.ro Integer32 .1.3.6.1.4.1.41112.1.5.2.2.1.2 |
ubntPowerOutCurrentOutput current in mA.ro Integer32 .1.3.6.1.4.1.41112.1.5.2.2.1.3 |
ubntPowerOutPowerOutput power in mW.ro Integer32 .1.3.6.1.4.1.41112.1.5.2.2.1.4 |
ubntPowerSupplies OBJECT IDENTIFIER .1.3.6.1.4.1.41112.1.5.3 |
ubntPsuBaysNumberThe number of PSU bays available on this system.ro Unsigned32 .1.3.6.1.4.1.41112.1.5.3.1 |
ubntPsuTableA list of PSU entries. The number of entries is given by the value of ubntPsuBaysNumber. SEQUENCE OF UbntPsuEntry .1.3.6.1.4.1.41112.1.5.3.2 |
ubntPsuEntryAn entry in the ubntPsuTable. UbntPsuEntry .1.3.6.1.4.1.41112.1.5.3.2.1 |
ubntPsuIndexA unique value for each PSU.ro Integer32 .1.3.6.1.4.1.41112.1.5.3.2.1.1 |
ubntPsuTypePSU Type.ro Enumeration .1.3.6.1.4.1.41112.1.5.3.2.1.2 |
ubntPsuStatusPSU Status.ro Enumeration .1.3.6.1.4.1.41112.1.5.3.2.1.3 |
ubntPsuOperStatusPSU operational status.ro Enumeration .1.3.6.1.4.1.41112.1.5.3.2.1.4 |
ubntPsuVoltagePSU voltage in mV.ro Integer32 .1.3.6.1.4.1.41112.1.5.3.2.1.5 |
ubntPsuTemperaturePSU temperature in thousands of degrees Celsius.ro Integer32 .1.3.6.1.4.1.41112.1.5.3.2.1.6 |
ubntPsuChargingShows PSU charging state if it is supported.ro Enumeration .1.3.6.1.4.1.41112.1.5.3.2.1.7 |
ubntPsuBatteryQuantityNumber of batteries connected to PSU.ro Integer32 .1.3.6.1.4.1.41112.1.5.3.2.1.8 |
ubntPsuBatteryChargeLevelCurrent battery charge level as a percent (0-100%).ro INTEGER .1.3.6.1.4.1.41112.1.5.3.2.1.9 |
ubntPsuBatteryTimeRemainingThe battery run time remaining before battery exhaustion.ro TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.41112.1.5.3.2.1.10 |
ubntPsuBatteryReplaceIndicatorIndicates whether the batteries need replacing.ro Enumeration .1.3.6.1.4.1.41112.1.5.3.2.1.11 |
ubntPsuBatteryLastReplaceDateBattery installation date (mm/dd/yyyy).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.41112.1.5.3.2.1.12 |
ubntThermometers OBJECT IDENTIFIER .1.3.6.1.4.1.41112.1.5.4 |
ubntThermometersCountThe number of installed thermometers on this system.ro Unsigned32 .1.3.6.1.4.1.41112.1.5.4.1 |
ubntThermsTableA list of thermometers entries. The number of entries is given by the value of ubntThermometersCount. SEQUENCE OF UbntThermsEntry .1.3.6.1.4.1.41112.1.5.4.2 |
ubntThermsEntryAn entry in the ubntThermsTable. UbntThermsEntry .1.3.6.1.4.1.41112.1.5.4.2.1 |
ubntThermIndexA unique value for thermometer.ro Integer32 .1.3.6.1.4.1.41112.1.5.4.2.1.1 |
ubntThermTypeType of thermometer.ro Enumeration .1.3.6.1.4.1.41112.1.5.4.2.1.2 |
ubntThermTemperatureTemperature in thousands of degrees Celsius.ro Integer32 .1.3.6.1.4.1.41112.1.5.4.2.1.3 |
ubntFans OBJECT IDENTIFIER .1.3.6.1.4.1.41112.1.5.5 |
ubntFansCountThe number of installed fans on this system.ro Unsigned32 .1.3.6.1.4.1.41112.1.5.5.1 |
ubntFansTableA list of fan entries. The number of entries is given by the value of ubntFansCount. SEQUENCE OF UbntFanEntry .1.3.6.1.4.1.41112.1.5.5.2 |
ubntFanEntryAn entry in the ubntFansTable. UbntFanEntry .1.3.6.1.4.1.41112.1.5.5.2.1 |
ubntFanIndexA unique value for fan.ro Integer32 .1.3.6.1.4.1.41112.1.5.5.2.1.1 |
ubntFanTypeType of fan.ro Enumeration .1.3.6.1.4.1.41112.1.5.5.2.1.2 |
ubntFanRpmFan RPM.ro Integer32 .1.3.6.1.4.1.41112.1.5.5.2.1.3 |
More MIBs from Ubiquiti
Browse all UbiquitiMIBs →The UBNT-AirFIBER-MIB enables SNMP-based monitoring and management of Ubiquiti AirFIBER point-to-point wireless bridges, exposing critical operational metrics such as link status, signal strength (RSSI), noise floor, transmit power, and interface error counters. This module facilitates the tracking of RF performance parameters and device health statistics essential for maintaining the stability and throughput of long-distance wireless backhaul links.
The UBNT-AirMAX-MIB enables SNMP-based monitoring and management of Ubiquiti AirMAX wireless radio units, providing access to critical performance metrics including link throughput, signal strength (RSSI), noise floor levels, interface error counters, and device temperature.
The UBNT-UFIBER-MIB module enables SNMP-based monitoring and management of Ubiquiti EdgeMax fiber optic network entities, specifically exposing performance metrics such as optical power levels, signal attenuation, and link status for fiber transceivers. This module facilitates the tracking of physical layer health and interface statistics essential for maintaining the integrity of Ubiquiti's fiber infrastructure.