Home/Catalog/TY3250I-MIB

TY3250I-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for TY3250I-MIB.

156
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

156 total
Object Name
RFC-1215
Unknown
.1.3.6.1.4.1.466
ty3250
OBJECT IDENTIFIER
.1.3.6.1.4.1.466.4
ty3250TrapA ty3250Trap trap signifies that the sending node had its `ty3250AlarmType` variable modified.
TRAP-TYPE
.1.3.6.1.4.1.466.4.0.0
ty3250coldstartcold-start.
TRAP-TYPE
.1.3.6.1.4.1.466.4.0.1
ty3250authenticationauthentication.
TRAP-TYPE
.1.3.6.1.4.1.466.4.0.2
ty3250t1netwcarrierlosst1-netw-carrier-loss.
TRAP-TYPE
.1.3.6.1.4.1.466.4.0.3
ty3250t1netwcarrierdetectt1-netw-carrier-detect.
TRAP-TYPE
.1.3.6.1.4.1.466.4.0.4
ty3250t1netwsynclossdeclaret1-netw-sync-loss-declare.
TRAP-TYPE
.1.3.6.1.4.1.466.4.0.5
ty3250t1netwsyncacquiret1-netw-sync-acquire.
TRAP-TYPE
.1.3.6.1.4.1.466.4.0.6
ty3250t1netwredalarmdeclaret1-netw-red-alarm-declare.
TRAP-TYPE
.1.3.6.1.4.1.466.4.0.7
ty3250t1netwredalarmcleart1-netw-red-alarm-clear.
TRAP-TYPE
.1.3.6.1.4.1.466.4.0.8
ty3250t1netwyellowalarmdetectt1-netw-yellow-alarm-detect.
TRAP-TYPE
.1.3.6.1.4.1.466.4.0.9
ty3250t1netwyellowalarmclear.
TRAP-TYPE
.1.3.6.1.4.1.466.4.0.10
ty3250t1netwaisdetectt1-netw-ais-detect.
TRAP-TYPE
.1.3.6.1.4.1.466.4.0.11
ty3250t1netwaiscleart1-netw-ais-clear.
TRAP-TYPE
.1.3.6.1.4.1.466.4.0.12
ty3250t1controlledslipt1-controlled-slip.
TRAP-TYPE
.1.3.6.1.4.1.466.4.0.13
ty3250configurationupdateconfiguration-update.
TRAP-TYPE
.1.3.6.1.4.1.466.4.0.14
ty3250diagnosticstatediagnostic-state.
TRAP-TYPE
.1.3.6.1.4.1.466.4.0.15
ty3250diagnosticcleardiagnostic-clear.
TRAP-TYPE
.1.3.6.1.4.1.466.4.0.16
ty3250SysTable
OBJECT IDENTIFIER
.1.3.6.1.4.1.466.4.1
ty3250SysTypeA textual description of the system model identifier. for example: TYLINK3250ro
DisplayString
.1.3.6.1.4.1.466.4.1.1
ty3250SysSoftRevDisplays the Software Revision installed in this node.ro
DisplayString
.1.3.6.1.4.1.466.4.1.2
ty3250SysHardRevDisplays the Hardware Revision of the node.ro
DisplayString
.1.3.6.1.4.1.466.4.1.3
ty3250SysNumT1InstalledThe number of network (T1) ports that are installed. There is 1 on the 3250.ro
INTEGER
.1.3.6.1.4.1.466.4.1.4
ty3250SysNumDteInstalledThe number of channels (DTE) that are installed. There is 1 on the 3250.ro
INTEGER
.1.3.6.1.4.1.466.4.1.5
ty3250SysNumCommInstalledThe number of Maintenance ports that are installed. The front panel MAINT port is for the user interface, the rear panel COMM port is for Lan(Network) Access.ro
INTEGER
.1.3.6.1.4.1.466.4.1.6
ty3250SysNameThe user supplied name of the node. This object does not affect operation, but may be useful for network management.rw
DisplayString
.1.3.6.1.4.1.466.4.1.7
ty3250SysResetNodeCommand to reset the node. NODE WILL BE OFF-LINE AND USER DATA WILL BE INTERRUPTED FOR APPROXIMATELY 15 SECONDS.rw
Enumeration
.1.3.6.1.4.1.466.4.1.8
ty3250CfgT1Table
OBJECT IDENTIFIER
.1.3.6.1.4.1.466.4.3
ty3250CfgT1FramingType of Framing on this T1 Line. Check with your service provider to determine value. D4 is also known as 'SuperFrame', ESF is 'Extended SuperFrame'. ESF provides enhanced performance monitoring capabilities. ANSI and 54016 refer to the ESF Facility Data Link (FDL).rw
Enumeration
.1.3.6.1.4.1.466.4.3.1
ty3250CfgT1LineEncodingT1 interface bipolar encoding scheme. Check with your service provider to determine value. B8ZS, which inherently provides ample 'ones-density', is recommended. AMI users must pay special attention to the 'ones-density' requirements of the servic provider.rw
Enumeration
.1.3.6.1.4.1.466.4.3.2
ty3250CfgT1DensityCSU 'ones density' monitor. Defines the maximum number of consecutive zeros that can be transmitted to the network. If density monitoring is enabled, the composite signal is guaranteed to meet the selected density threshhold at the expense of user data. No-density (4) should be used if B8ZS Line Encoding is chosen or if Channel Density is bit-7-stuff. This option is not applicable if DSX-1 mode is selected.rw
Enumeration
.1.3.6.1.4.1.466.4.3.3
ty3250CfgT1InterfaceEnables CSU-specific functions if CSU (1) is selected. CSU functions include Line Build-out, density monitoring, and certain diagnostic features. Selecting DSX-1 (2) will disable these CSU functions for line driver or external CSU applications.rw
Enumeration
.1.3.6.1.4.1.466.4.3.4
ty3250CfgT1LboSettingCSU Line Build Out. Consult service provider for proper setting; either 0dB (1), -7.5dB (2), or -15dB (3). Not applicable if T1Interface = dsx1.rw
Enumeration
.1.3.6.1.4.1.466.4.3.5
ty3250CfgT1TimingT1 network interface timing source. There must be only one source on a T1 line. Node should typically be network (2) timed on a point-to-network application. Line Driver and point-to-point applications typically need one node as internal (1), one as network (2).rw
Enumeration
.1.3.6.1.4.1.466.4.3.6
ty3250CfgT1CicuitIDThis variable contains the transmission vendor's circuit identifier, for the purpose of facilitating troubleshooting.rw
DisplayString
.1.3.6.1.4.1.466.4.3.7
ty3250CfgDteTable
OBJECT IDENTIFIER
.1.3.6.1.4.1.466.4.4
ty3250CfgDteLineRateSerial Data Rate in bits-per-second, must be multiple of 8000bps. For example enter 768000 for 768Kb/s. Valid rates depend upon channel density selection: nX56K for bit-7-stuffing, and nX64K for clear-channel (n is an integer 1-24 inclusive).rw
INTEGER
.1.3.6.1.4.1.466.4.4.1
ty3250CfgDteChannelDensityPacking of serial data into T1 DS0's. Bit-7-stuff (56) allows DTE rates of nX56Kb/s and provides sufficient ones-density on any circuit. Clear-channel (64) allows rates on nX64Kb/s and may require an additional means of density enforcement (eg, B8ZS).rw
Enumeration
.1.3.6.1.4.1.466.4.4.2
ty3250CfgDteTimingSerial DTE Transmit Timing mode. Loop-1 (1) uses the clock returned from the DTE (TT/TCE) to sample tx data, Loop-2 (2) uses the clock (ST/TC) generated by the node to sample tx data.rw
Enumeration
.1.3.6.1.4.1.466.4.4.3
ty3250CfgDteClockModeClock-normal samples data with the rising edge of the selected tx clock, clock-invert samples data with the falling edge of the selected tx clock. The tx clock is selected using CfgDteTiming. This clock invertion is most useful when loop-2 timing is used. Only in rare circumstances will clock-invert (2) be used with loop-1 timing.rw
Enumeration
.1.3.6.1.4.1.466.4.4.4
ty3250CfgDteDataModeInverts data. Can make some applications, particularly HDLC-based protocols, meet density requirements even across clear channel DS0s in AMI mode.rw
Enumeration
.1.3.6.1.4.1.466.4.4.5
ty3250CfgDteIntfTypeSets the electrical interface for the DTE port.rw
Enumeration
.1.3.6.1.4.1.466.4.4.6
ty3250CfgConnectTable
OBJECT IDENTIFIER
.1.3.6.1.4.1.466.4.5
ty3250CfgConnAutoAssign
OBJECT IDENTIFIER
.1.3.6.1.4.1.466.4.5.1
ty3250ConnAutoT1IndexIndex to T1 network port of interest. 3250 supports one T1 network port (1)rw
INTEGER
.1.3.6.1.4.1.466.4.5.1.1
ty3250ConnStartDS0Port1-t1 includes 24 DS0's. This value is the starting DS0 used by the node to allocate DS0s to meet port2-dte's requirements. Sequential, contiguous DS0s are assigned. The number of DS0s required is based upon the DTE Data Rate and DTE Channel Mapping. The node's response to an entry may be gathered by querying ty3250ConnAutoStatus. To assign DS0s in a non-contiguous format, use the CfgEditConnTable.rw
Enumeration
.1.3.6.1.4.1.466.4.5.1.2
ty3250ConnAutoPortSelects the port for which DS0s are automatically allocated to on the T1 network port. Node software may not allow connection of port1-t1 to port1-t1.rw
Enumeration
.1.3.6.1.4.1.466.4.5.1.3
ty3250ConnAutoTypeDefines the type of traffic being transported. The 3250 only supports data (1). The selected type will be assigned to all DS0s.rw
Enumeration
.1.3.6.1.4.1.466.4.5.1.4
ty3250ConnDteRateData rate of the 3250's DTE port. Can be changed from the CfgDteTable.ro
INTEGER
.1.3.6.1.4.1.466.4.5.1.5
ty3250ConnDteDensityChannel/DS0 format for the 3250's DTE port. Can be changed from the CfgDteTable.ro
Enumeration
.1.3.6.1.4.1.466.4.5.1.6
ty3250ConnDs0RequiredThe number of DS0s required by the node's DTE port. This is based upon the DTE data rate and channel density selections.ro
INTEGER
.1.3.6.1.4.1.466.4.5.1.7
ty3250ConnAutoStatusQueries the node's connection status. Cause codes will be returned when a connection set is rejected.ro
Enumeration
.1.3.6.1.4.1.466.4.5.1.8
ty3250CfgCurrentConnTableRetrieves node's active connections assignments for display only. To edit connections, use CfgConnAutoAssign or CfgEditConnTable.
SEQUENCE OF Ty3250CfgCurrentConnections
.1.3.6.1.4.1.466.4.5.2
ty3250CfgCurrentConnectionsAn entry in the Current Connections Table.
Ty3250CfgCurrentConnections
.1.3.6.1.4.1.466.4.5.2.1
ty3250T1IndexIndex to T1 network port of interest. 3250 only supports one T1 network port (1)ro
INTEGER
.1.3.6.1.4.1.466.4.5.2.1.1
ty3250Ds0DS0 number 1 through 24 corresponding to the T1 network port indexro
INTEGER
.1.3.6.1.4.1.466.4.5.2.1.2
ty3250DtePortDS0 assignment for indexed T1 network port. After making any adjustments to the connections, the ty3250CfgConnUpdateCmd must be sent. Node software may not permit port1-t1 connections to itself.ro
Enumeration
.1.3.6.1.4.1.466.4.5.2.1.3
ty3250TypeDefines the type of traffic being transported. The 3250 only supports data (1).ro
Enumeration
.1.3.6.1.4.1.466.4.5.2.1.4
ty3250CfgEditConnMenu
OBJECT IDENTIFIER
.1.3.6.1.4.1.466.4.5.3
ty3250CfgEditConnCopyCurrtoEditFill the edit buffer with the node's current active connections.rw
Enumeration
.1.3.6.1.4.1.466.4.5.3.1
ty3250CfgEditConnTableEdits current DS0 assignment. After making any adjustments to the connections, the ty3250CfgConnUpdateCmd must be sent.
SEQUENCE OF Ty3250CfgEditConnEntry
.1.3.6.1.4.1.466.4.5.3.2
ty3250CfgEditConnEntryAn entry in the Edit Connections table.
Ty3250CfgEditConnEntry
.1.3.6.1.4.1.466.4.5.3.2.1
ty3250ConnT1IndexIndex to T1 network port of interest. 3250 only supports one T1 network port (1)ro
INTEGER
.1.3.6.1.4.1.466.4.5.3.2.1.1
ty3250ConnDS0DS0 number 1 through 24 corresponding to the T1 network port indexro
INTEGER
.1.3.6.1.4.1.466.4.5.3.2.1.2
ty3250ConnDTEDS0 assignment for indexed T1 network port. After making any adjustments to the connections, the ty3250CfgConnUpdateCmd must be sent. Node software may not permit connections between port1-t1 and itself.rw
Enumeration
.1.3.6.1.4.1.466.4.5.3.2.1.3
ty3250ConnTypedefines the type of traffic being transported. The 3250 only supports data (1).rw
Enumeration
.1.3.6.1.4.1.466.4.5.3.2.1.4
ty3250CfgConnUpdate
OBJECT IDENTIFIER
.1.3.6.1.4.1.466.4.5.3.3
ty3250CfgConnUpdateCmdUpdates the connections with the edit buffer. The edit buffer is comprised of any changes sent (set) from the CfgEditConnTable.rw
Enumeration
.1.3.6.1.4.1.466.4.5.3.3.1
ty3250CfgConnStatusDisplays node status from the last connection update.ro
Enumeration
.1.3.6.1.4.1.466.4.5.3.3.2
ty3250CfgEditConnClearEditBuffRemoves all changes from edit buffer. The edit buffer is comprised of any changes sent (set) from the CfgEditConnTable.rw
Enumeration
.1.3.6.1.4.1.466.4.5.3.4
ty3250CfgCommTable
OBJECT IDENTIFIER
.1.3.6.1.4.1.466.4.6
ty3250CfgCommFormat
SEQUENCE OF Ty3250CfgCommIntf
.1.3.6.1.4.1.466.4.6.1
ty3250CfgCommIntfConfiguration of electrical interface and character format of the communications ports.
Ty3250CfgCommIntf
.1.3.6.1.4.1.466.4.6.1.1
ty3250CfgCommIndexThe comm (1) is at the rear and the maint (2) is at the front of the box.ro
Enumeration
.1.3.6.1.4.1.466.4.6.1.1.1
ty3250CfgCommBaudBaud rate for this Communication port. Values are baud-1200 (1), baud-2400 (2), baud-4800 (3), baud-9600 (4), baud-19200 (5), baud-38400 (6).rw
Enumeration
.1.3.6.1.4.1.466.4.6.1.1.2
ty3250CfgCommDataBitsDatabits for this Communication port. Values are databits-7 (1) and databits-8 (2).rw
Enumeration
.1.3.6.1.4.1.466.4.6.1.1.3
ty3250CfgCommStopBitsNumber of Stopbits for this Communication port. Values are stopbits-1 (1), stopbits-1-5 (2), and stopbits-2 (3).rw
Enumeration
.1.3.6.1.4.1.466.4.6.1.1.4
ty3250CfgCommParityParity for this Communication port. Values are no-parity (1), odd-parity (2), even-parity (3).rw
Enumeration
.1.3.6.1.4.1.466.4.6.1.1.5
ty3250CfgCommFlowCtrlFlow Control for this Communication port. Values are off-flow-control (1) and on-flow-control (2).rw
Enumeration
.1.3.6.1.4.1.466.4.6.1.1.6
ty3250CfgCommModeTable
SEQUENCE OF Ty3250CfgCommMode
.1.3.6.1.4.1.466.4.6.2
ty3250CfgCommModeEntryAscii communication port configuration.
Ty3250CfgCommMode
.1.3.6.1.4.1.466.4.6.2.1
ty3250CfgCommModeIndexCommunication port configured as user interface. The comm (1) is at the rear and the maint (2) is at the front of the box. The 3250 may require that the maint (2) port be used for user interface only.rw
Enumeration
.1.3.6.1.4.1.466.4.6.2.1.1
ty3250CfgCommModeDefines mode of operation of the selected communication port. The 3250 may require that the user-interface be assigned to the Maint port and a Network access type be assigned to the COMM port.rw
Enumeration
.1.3.6.1.4.1.466.4.6.2.1.2
ty3250CfgCommMyIPThe IP address for this node's network access port.rw
IpAddress
.1.3.6.1.4.1.466.4.6.2.1.3
ty3250CfgCommPeerIPThe IP address for other end of network access connection.rw
IpAddress
.1.3.6.1.4.1.466.4.6.2.1.4
ty3250CfgCommMaskThe IP Network Mask (eg 255.255.255.0) for the network access link.rw
IpAddress
.1.3.6.1.4.1.466.4.6.2.1.5
ty3250CfgCommMaxMTUThe Maximum Transmission Unit is the size of the largest IP packet supported. This value should be set to the lowest value supported by any equipment in the transmission path.rw
INTEGER
.1.3.6.1.4.1.466.4.6.2.1.6
ty3250CfgSnmpTableIP addresses and corresponding trap filters.
SEQUENCE OF Ty3250SnmpEntry
.1.3.6.1.4.1.466.4.7
ty3250SnmpEntryentry of IP addresses and corresponding trap filters.
Ty3250SnmpEntry
.1.3.6.1.4.1.466.4.7.1
ty3250SnmpIndexThe index to one of the SNMP manager's address and filter configurations.rw
INTEGER
.1.3.6.1.4.1.466.4.7.1.1
ty3250SnmpManagerIPThe IP address for the SNMP manager to receive this node's TRAPs.rw
IpAddress
.1.3.6.1.4.1.466.4.7.1.2
ty3250DiagT1Table
OBJECT IDENTIFIER
.1.3.6.1.4.1.466.4.10
ty3250DiagT1LocLineLpbkLocal Line Loopback on the T1 network port. Data and framing received from the network is transmitted back to the networkrw
Enumeration
.1.3.6.1.4.1.466.4.10.1
ty3250DiagT1LocPylLpbkLocal Payload Loopback on the T1 network port. Data (NOT framing) received from the network is reframed and transmitted back to the network.rw
Enumeration
.1.3.6.1.4.1.466.4.10.2
ty3250DiagT1LocAggrLpbkLocal Aggregate Loopback on the T1 network port. Data from the DTE is framed for transmission and looped back through the network receiver towards the DTE.rw
Enumeration
.1.3.6.1.4.1.466.4.10.3
ty3250DiagT1RmtLpbkStatusStatus of Remote Loopbacks received from the T1 network port. csu-lpbk-from-remote (1) indicates the node is in a Network Line Loopback state due to the reception of the CSU Loop-up pattern from the network. dsu-lpbk-from-remote (2) indicates the node is in a Network Line Loopback state due to the reception of the TyLink proprietary Loop-up pattern a remote node. pyl-lpbk-from-remote (3) indicates the node is in a Payload Loopback state due to the reception of the Facility Data Link's Loop-up pattern from the network (ESF only). csu-lpbk-sent-to-remote (4) indicates the node sent a csu loop up pattern to the remote. The node doesn't know if the loopback was accepted by the remote unit. dsu-lpbk-sent-to-remote (5) indicates the node sent a dsu loop up pattern to the remote. The node doesn't know if the loopback was accepted by the remote unit.ro
Enumeration
.1.3.6.1.4.1.466.4.10.4
ty3250DiagT1RmtLpbkCmdRemote loopbacks that can be transmitted out the T1 network port. rmt-csu-lpbk-loopup (1) sends standard CSU loop up code into the network. rmt-csu-lpbk-loopdown (2) sends standard CSU loop down code into the network. rmt-dsu-lpbk-loopup (3) sends TyLink proprietary loop up code into the network. rmt-dsu-lpbk-loopdown (4) sends TyLink proprietary loop up code into the network.rw
Enumeration
.1.3.6.1.4.1.466.4.10.5
ty3250DiagDteTable
OBJECT IDENTIFIER
.1.3.6.1.4.1.466.4.11
ty3250DiagDteLocBidirLpbkLocal Bi-directional Loopback on the DTE port. Loops the clock and data back to the DTE at the interface on the 3250; also loops the DTE's network bandwidth back to the network.rw
Enumeration
.1.3.6.1.4.1.466.4.11.1
ty3250DiagDteRmtLpbkStatusStatus of Remote Loopbacks received for the DTE port. bidir-lpbk-from-remote indictaes that either a proprietary or V54 loop up pattern was received on the DTE's network bandwidth. bidir-lpbk-sent-to-remote indiactes that either a proprietary or V54 loop up pattern was sent to the remote DTE.ro
Enumeration
.1.3.6.1.4.1.466.4.11.2
ty3250DiagDteRmtLpbkCmdRemote loopbacks that can be transmitted to a remote DTE port rmt-bidir-lpbk-loopup-tyl (1) sends the TyLink proprietary loop up pattern to a remote TyLink DTE. When detected by the remote unit, a DTE Bidirectional Loopback is put up. rmt-bidir-lpbk-loopdown-tyl (2) sends the TyLink proprietary loop down pattern to a remote TyLink DTE. When detected by the remote unit, a DTE Bidirectional Loopback is torn down. rmt-bidir-lpbk-loopup-V54 (3) sends the standard V.54 loop up pattern to a remote, V54-compatible DTE. When detected by the remote unit, a DTE Bidirectional Loopback is put up. rmt-bidir-lpbk-loopdown-V54 (4) sends the standard V.54 loop down pattern to a remote, V54-compatible DTE. When detected by the remote unit, a DTE Bidirectional Loopback is torn down.rw
Enumeration
.1.3.6.1.4.1.466.4.11.3
ty3250DiagBerTable
OBJECT IDENTIFIER
.1.3.6.1.4.1.466.4.12
ty3250DiagBerPattrnselects pseudorandom pattern for bit error rate testrw
Enumeration
.1.3.6.1.4.1.466.4.12.1
ty3250DiagBerStateBERT test related actions: a: Starts a BERT test on selected bandwidth, b: Stops a BERT test on selected bandwidth, c: Inject Errors while the BERT test is running, d: Clears BERT test errors.rw
Enumeration
.1.3.6.1.4.1.466.4.12.2
ty3250DiagBerStatusDisplays the current BERT test sync status.ro
Enumeration
.1.3.6.1.4.1.466.4.12.3
ty3250DiagBerErrorsDisplays the number of errors detected in Bert Test.ro
Counter
.1.3.6.1.4.1.466.4.12.4
ty3250DiagBerTimeElapsElapsed time since BERT test was started or cleared.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.466.4.12.5
ty3250PortStatusTableStatus of a T1 or DTE port.
SEQUENCE OF Ty3250PortStatus
.1.3.6.1.4.1.466.4.13
ty3250PortStatusAn entry in the DS1 Interval table.
Ty3250PortStatus
.1.3.6.1.4.1.466.4.13.1
ty3250IntfIndexThe index value which uniquely identifies the interface to which this entry is applicable.ro
INTEGER
.1.3.6.1.4.1.466.4.13.1.1
ty3250IntfTypePort type.ro
Enumeration
.1.3.6.1.4.1.466.4.13.1.2
ty3250IntfModeStatus of the indexed port. Inactive (1) indicates the port has no connections. Active (2) indicates connections and data mode. Test-mode (3) indicates connections and diagnostic state for that port.ro
Enumeration
.1.3.6.1.4.1.466.4.13.1.3
ty3250IntfStatusStatus of the indexed port.ro
Enumeration
.1.3.6.1.4.1.466.4.13.1.4
ty3250IntfAlarmsAlarms present at the indexed port. The node software may not support DTE alarm conditions.ro
Enumeration
.1.3.6.1.4.1.466.4.13.1.5
ty3250PerfT1CurrentTableThe T1 performance numbers for the current 15 minute interval.
SEQUENCE OF Ty3250T1CurrentEntry
.1.3.6.1.4.1.466.4.14
ty3250T1CurrentEntryAn entry in the T1 Current Perf table.
Ty3250T1CurrentEntry
.1.3.6.1.4.1.466.4.14.1
ty3250T1CurrentIndexThe index value which uniquely identifies the T1 interface to which this entry is applica- ble.ro
INTEGER
.1.3.6.1.4.1.466.4.14.1.1
ty3250T1CurrentCrc6EventsCount of CRC errors detected on an ESF framed circuit. In ESF framing a CRC is generated at the source, based upon the composite data. A CRC error indicates the presence of at least one bit error in an ESF superframe. This field is a free-running accumulation of CRC errors and IS NOT reset when the current 15 minute interval expires. It can be reset with the performance command ty3250T1PerfClearEvents. Not applicable if D4/SF framing is selcted.ro
Gauge
.1.3.6.1.4.1.466.4.14.1.2
ty3250T1CurrentOofEventsCount of Out-of-Frame events on a T1 circuit. An out-of- frame event occurs when the frame synchronization criteria is lost and a resynchronization must occur. Data is interrupted during frame resynchronization. This field is a free-running accumulation of OOF transitions and IS NOT reset when the current 15 minute interval expires. It can be reset with the performance command ty3250T1PerfClearEvents.ro
Gauge
.1.3.6.1.4.1.466.4.14.1.3
ty3250T1CurrentESsThe number of Errored Seconds, encountered by a T1 interface in the current 15 minute inter- val. An errored second is a one-second interval with CRC errors or a loss of frame sync occurred.ro
Gauge
.1.3.6.1.4.1.466.4.14.1.4
ty3250T1CurrentSESsThe number of Severely Errored Seconds encoun- tered by a t1 interface in the current 15 minute interval. A severely errored second is a one second interval with more than 320 CRC errors or one or more frame sync losses.ro
Gauge
.1.3.6.1.4.1.466.4.14.1.5
ty3250T1CurrentSEFSsThe number of Severely Errored Framing Seconds encountered by a t1 interface in the current 15 minute interval. A SEFS is a one second interval with one or more frame sync losses.ro
Gauge
.1.3.6.1.4.1.466.4.14.1.6
ty3250T1CurrentUASsThe number of Unavailable Seconds encountered by a t1 interface in the current 15 minute in- terval. A UAS is a one second interval during which the received signal is classified as 'unavailable due to excessive errors'. A signal is unavailable after receiving ten consective severely errored seconds and stays unavailable until ten seconds without a severely errored second occur.ro
Gauge
.1.3.6.1.4.1.466.4.14.1.7
ty3250T1CurrentCSSsThe number of Controlled Slip Seconds encoun- tered by a t1 interface in the current 15 minute interval. A controlled slip is the replication or deletion of a T1 frame at the receiver. These events often indicate a T1 network timing problem.ro
Gauge
.1.3.6.1.4.1.466.4.14.1.8
ty3250T1CurrentBESsThe number of Bursty Errored Seconds (BESs) encountered by a DS1 interface in the current 15 minute interval. A BES is a one second interval with more than one and less than 320 CRC errors.ro
Gauge
.1.3.6.1.4.1.466.4.14.1.9
ty3250T1CurrentLCVsThe number of Line Code Violations (LCVs) en- countered by a DS1 interface in the current 15 minute interval. LCVs are non-B8ZS related violations of the alternate mark inversion protocol. An excessive count usually indicates a B8ZS/AMI configuration mismatch in the T1 network.ro
Gauge
.1.3.6.1.4.1.466.4.14.1.10
ty3250PerfT1IntervalTableThe DS1 Interval table.
SEQUENCE OF Ty3250T1IntervalEntry
.1.3.6.1.4.1.466.4.15
ty3250T1IntervalEntryAn entry in the DS1 Interval table.
Ty3250T1IntervalEntry
.1.3.6.1.4.1.466.4.15.1
ty3250T1IntervalIndexThe index value which uniquely identifies the t1 interface to which this entry is applica- ble. The interface identified by a particular value of this index is the same interface as identified by the same value as a NetwLineIndex object instance.ro
INTEGER
.1.3.6.1.4.1.466.4.15.1.1
ty3250T1IntervalNumberA number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes inter- val (assuming that all 96 intervals are valid).ro
INTEGER
.1.3.6.1.4.1.466.4.15.1.2
ty3250T1IntervalESsThe number of Errored Seconds encountered by a t1 interface in one of the previous 96, indi- vidual 15 minute, intervals. An errored second is a one-second interval with CRC errors or a loss of frame sync occurred.ro
Gauge
.1.3.6.1.4.1.466.4.15.1.3
ty3250T1IntervalSESsThe number of Severely Errored Seconds encoun- tered by a t1 interface in one of the previous 96, individual 15 minute, intervals. A severely errored second is a one second interval with more than 320 CRC errors or one or more frame sync losses.ro
Gauge
.1.3.6.1.4.1.466.4.15.1.4
ty3250T1IntervalSEFSsThe number of Severely Errored Framing Seconds encountered by a t1 interface in one of the previous 96, individual 15 minute, intervals. A SEFS is a one second interval with one or more frame sync losses.ro
Gauge
.1.3.6.1.4.1.466.4.15.1.5
ty3250T1IntervalUASsThe number of Unavailable Seconds encountered by a t1 interface in one of the previous 96, individual 15 minute, intervals. A UAS is a one second interval during which the received signal is classified as 'unavailable due to excessive errors'. A signal is unavailable after receiving ten consective severely errored seconds and stays unavailable until ten seconds without a severely errored second occur.ro
Gauge
.1.3.6.1.4.1.466.4.15.1.6
ty3250T1IntervalCSSsThe number of Controlled Slip Seconds encoun- tered by a t1 interface in one of the previous 96, individual 15 minute, intervals. A controlled slip is the replication or deletion of a T1 frame at the receiver. These events often indicate a T1 network timing problem.ro
Gauge
.1.3.6.1.4.1.466.4.15.1.7
ty3250T1IntervalBESsThe number of Bursty Errored Seconds (BESs) encountered by a t1 interface in one of the previous 96, individual 15 minute, intervals. A BES is a one second interval with more than one and less than 320 CRC errors.ro
Gauge
.1.3.6.1.4.1.466.4.15.1.8
ty3250T1IntervalLCVsThe number of Line Code Violations (LCVs) en- countered by a DS1 interface in the current 15 minute interval. LCVs are non-B8ZS related violations of the alternate mark inversion protocol. An excessive count usually indicates a B8ZS/AMI configuration mismatch in the T1 network.ro
Gauge
.1.3.6.1.4.1.466.4.15.1.9
ty3250PerfT1TotalTableThe T1 Total table. 24 hour interval.
SEQUENCE OF Ty3250T1TotalEntry
.1.3.6.1.4.1.466.4.16
ty3250T1TotalEntryAn entry in the T1 Total table.
Ty3250T1TotalEntry
.1.3.6.1.4.1.466.4.16.1
ty3250T1TotalIndexThe index value which uniquely identifies the t1 interface to which this entry is applica- ble. The interface identified by a particular value of this index is the same interface as identified by the same value as a NetwLineIndex object instance.ro
INTEGER
.1.3.6.1.4.1.466.4.16.1.1
ty3250T1TotalESsThe number of Errored Seconds encountered by a t1 interface in the previous 24 hour interval. An errored second is a one-second interval with CRC errors or a loss of frame sync occurred.ro
Gauge
.1.3.6.1.4.1.466.4.16.1.2
ty3250T1TotalSESsThe number of Severely Errored Seconds encoun- tered by a t1 interface in the previous 24 hour interval. A severely errored second is a one second interval with more than 320 CRC errors or one or more frame sync losses.ro
Gauge
.1.3.6.1.4.1.466.4.16.1.3
ty3250T1TotalSEFSsThe number of Severely Errored Framing Seconds 24 hour interval. A SEFS is a one second interval with one or more frame sync losses.ro
Gauge
.1.3.6.1.4.1.466.4.16.1.4
ty3250T1TotalUASsThe number of Unavailable Seconds encountered by a t1 interface in the previous 24 hour in- terval. A UAS is a one second interval during which the received signal is classified as 'unavailable due to excessive errors'. A signal is unavailable after receiving ten consective severely errored seconds and stays unavailable until ten seconds without a severely errored second occur.ro
Gauge
.1.3.6.1.4.1.466.4.16.1.5
ty3250T1TotalCSSsThe number of Controlled Slip Seconds encoun- tered by a t1 interface in the previous 24 hour interval. A controlled slip is the replication or deletion of a T1 frame at the receiver. These events often indicate a T1 network timing problem.ro
Gauge
.1.3.6.1.4.1.466.4.16.1.6
ty3250T1TotalBESsThe number of Bursty Errored Seconds (BESs) encountered by a t1 interface in the previous 24 hour interval. A BES is a one second interval with more than one and less than 320 CRC errors.ro
Gauge
.1.3.6.1.4.1.466.4.16.1.7
ty3250T1TotalLCVsThe number of Line Code Violations (LCVs) en- countered by a t1 interface in the current 15 minute interval. LCVs are non-B8ZS related violations of the alternate mark inversion protocol. An excessive count usually indicates a B8ZS/AMI configuration mismatch in the T1 network.ro
Gauge
.1.3.6.1.4.1.466.4.16.1.8
ty3250T1PerfCmdTypeTableAn entry in the DS1 Interval table.
SEQUENCE OF Ty3250T1PerfCmdType
.1.3.6.1.4.1.466.4.17
ty3250T1PerfCmdTypeAn entry in the DS1 Interval table.
Ty3250T1PerfCmdType
.1.3.6.1.4.1.466.4.17.1
ty3250T1CommandIndexThe index value which uniquely identifies the t1 interface to which this command is applica- ble.rw
INTEGER
.1.3.6.1.4.1.466.4.17.1.1
ty3250T1PerfFreezeStateThis command halts the node's performance monitoring and freezes the current, interval, and total performance register values.rw
Enumeration
.1.3.6.1.4.1.466.4.17.1.2
ty3250T1PerfClearEventsThis command resets all of the (user's) error event registers. This includes the CRC6 and Out-of-Frame counts. It does not affect the interval or 24 hour performance totals.rw
Enumeration
.1.3.6.1.4.1.466.4.17.1.3
ty3250T1PerfClearAllThis command resets all of the (user's) performance registers.rw
Enumeration
.1.3.6.1.4.1.466.4.17.1.4
ty3250AlarmTypeThe type of alarms that are generated on the nodero
Enumeration
.1.3.6.1.4.1.466.4.18