Home/Catalog/TY1250I-MIB

TY1250I-MIB

Detailed view of the defined objects, syntax rules, and hierarchical paths.

121
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

121 total
Object Name
RFC-1215
Unknown
.1.3.6.1.4.1.466
dsucsu
OBJECT IDENTIFIER
.1.3.6.1.4.1.466.1
tyview
OBJECT IDENTIFIER
.1.3.6.1.4.1.466.2
ty1250
OBJECT IDENTIFIER
.1.3.6.1.4.1.466.3
ty1250TrapA ty1250Trap trap signifies that the sending node had its `ty1250AlarmType` variable modified.
TRAP-TYPE
.1.3.6.1.4.1.466.3.0.0
ty1250LineFailureTrapThe line has failed.
TRAP-TYPE
.1.3.6.1.4.1.466.3.0.1
ty1250LineInServiceTrapThe line is back in service.
TRAP-TYPE
.1.3.6.1.4.1.466.3.0.2
ty1250ConnectedTrapThe 1250 unit is connected.
TRAP-TYPE
.1.3.6.1.4.1.466.3.0.3
ty1250ConnectFailureTrapThe attempted connection failed.
TRAP-TYPE
.1.3.6.1.4.1.466.3.0.4
ty1250IncomingCallTrapIncoming call.
TRAP-TYPE
.1.3.6.1.4.1.466.3.0.5
ty1250DisconnectedTrapDisconnected.
TRAP-TYPE
.1.3.6.1.4.1.466.3.0.6
ty1250BadConfigTrapThe configuration specified in the SET command was bad. SET failed.
TRAP-TYPE
.1.3.6.1.4.1.466.3.0.7
ty1250LocalConfigTrapThe configuration has been changed by a means other than SNMP.
TRAP-TYPE
.1.3.6.1.4.1.466.3.0.8
ty1250BPVThresholdExceededTrapBPV threshold exceeded.
TRAP-TYPE
.1.3.6.1.4.1.466.3.0.9
ty1250BPVThresholdAcceptableTrapBPV threshold acceptable.
TRAP-TYPE
.1.3.6.1.4.1.466.3.0.10
ty1250LocalUnitLoopbackEnabledTrapLocal unit loopback enabled.
TRAP-TYPE
.1.3.6.1.4.1.466.3.0.11
ty1250LocalUnitLoopbackDisabledTrapLocal unit loopback disabled.
TRAP-TYPE
.1.3.6.1.4.1.466.3.0.12
ty1250LocalNetLoopbackEnabledTrapLocal network loopback enabled.
TRAP-TYPE
.1.3.6.1.4.1.466.3.0.13
ty1250LocalNetLoopbackDisabledTrapLocal network loopback disabled.
TRAP-TYPE
.1.3.6.1.4.1.466.3.0.14
ty1250SimplexCurrentLoopbackEnabledTrapSimplex current loopback enabled.
TRAP-TYPE
.1.3.6.1.4.1.466.3.0.15
ty1250SimplexCurrentLoopbackDisabledTrapSimplex current loopback disabled.
TRAP-TYPE
.1.3.6.1.4.1.466.3.0.16
ty1250NonLatchingLoopbackEnabledTrapNonlatching loopback enabled.
TRAP-TYPE
.1.3.6.1.4.1.466.3.0.17
ty1250NonLatchingLoopbackDisabledTrapNonlatching loopback disabled.
TRAP-TYPE
.1.3.6.1.4.1.466.3.0.18
ty1250V54LoopUpInitiatedTrapStarting to loop up a V54 loopback on the remote unit.
TRAP-TYPE
.1.3.6.1.4.1.466.3.0.19
ty1250V54LoopDownCompletedTrapCompleted the loop down of a V54 loopback on the remote unit.
TRAP-TYPE
.1.3.6.1.4.1.466.3.0.20
ty1250V54LoopbackEnabledTrapV54 loopback enabled by remote unit.
TRAP-TYPE
.1.3.6.1.4.1.466.3.0.21
ty1250V54LoopbackDisabledTrapV54 loopback disabled by remote unit.
TRAP-TYPE
.1.3.6.1.4.1.466.3.0.22
ty1250BertInitiatedTrapBERT test pattern initiated.
TRAP-TYPE
.1.3.6.1.4.1.466.3.0.23
ty1250BertCompletedTrapBERT test pattern completed.
TRAP-TYPE
.1.3.6.1.4.1.466.3.0.24
ty1250LocalDteLoopbackEnabledTrapLocal DTE loopback enabled.
TRAP-TYPE
.1.3.6.1.4.1.466.3.0.25
ty1250LocalDteLoopbackDisabledTrapLocal DTE loopback disabled.
TRAP-TYPE
.1.3.6.1.4.1.466.3.0.26
ty1250LocalUnitLoopbackFailedTrapUnable to do a local unit loopback.
TRAP-TYPE
.1.3.6.1.4.1.466.3.0.27
ty1250LocalNetLoopbackFailedTrapUnable to do a local network loopback.
TRAP-TYPE
.1.3.6.1.4.1.466.3.0.28
ty1250BertFailedTrapUnable to do a BERT.
TRAP-TYPE
.1.3.6.1.4.1.466.3.0.29
ty1250LocalDteLoopbackFailedTrapUnable to do a local DTE loopback.
TRAP-TYPE
.1.3.6.1.4.1.466.3.0.30
ty1250V54LoopbackFailedTrapUnable to do a V54 loopback.
TRAP-TYPE
.1.3.6.1.4.1.466.3.0.31
ty1250SysTable
OBJECT IDENTIFIER
.1.3.6.1.4.1.466.3.1
ty1250SysTypeA textual description of the system model identifier. for example: TYLINK1250ro
DisplayString
.1.3.6.1.4.1.466.3.1.1
ty1250SysSoftRevDisplays the Software Revision installed in this node.ro
DisplayString
.1.3.6.1.4.1.466.3.1.2
ty1250SysHardRevDisplays the Hardware Revision of the node.ro
DisplayString
.1.3.6.1.4.1.466.3.1.3
ty1250SysNumNetInstalledThe number of Network (DDS) ports that are installed. There is 1 on the 1250.ro
INTEGER
.1.3.6.1.4.1.466.3.1.4
ty1250SysNumDteInstalledThe number of channels (DTE) that are installed. There is 1 on the 1250.ro
INTEGER
.1.3.6.1.4.1.466.3.1.5
ty1250SysNumMaintInstalledThe number of Maintenance ports that are installed. There are 2 on the 1250.ro
INTEGER
.1.3.6.1.4.1.466.3.1.6
ty1250SysNameThe user supplied name of the node. This object does not affect operation, but may be useful for network management.rw
DisplayString
.1.3.6.1.4.1.466.3.1.7
ty1250CfgAppTable
OBJECT IDENTIFIER
.1.3.6.1.4.1.466.3.2
ty1250CfgAppClockSourceDefault timing, or clock, source. There must be only one source on a DDS line. Node should always be network (2) timed on a point-to-network application. Line Driver applications need one node as internal (1), one as network (2).rw
Enumeration
.1.3.6.1.4.1.466.3.2.2
ty1250CfgAppCircuitIdCircuit identifier provided by the service provider.rw
DisplayString
.1.3.6.1.4.1.466.3.2.3
ty1250CfgNetTable
OBJECT IDENTIFIER
.1.3.6.1.4.1.466.3.3
ty1250CfgNetGlareTypeIn switched applications, defines who wins when there are simultanious incomming and outgoing calls. If in doubt, select external-glare (2).rw
Enumeration
.1.3.6.1.4.1.466.3.3.4
ty1250CfgNetEchoCanIn switched applications, some carriers, such as Sprint, require you to disable-echo-cancellors (2) for data apps on most lines. Calls take longer to come up when disabling is done; use ignore-echo-cancellers (1) on clear channel lines.rw
Enumeration
.1.3.6.1.4.1.466.3.3.5
ty1250CfgNetAnsModeIn switched applications, allows for manual-answer (1) or automatic-answer (2) of inbound calls. Calls may be answered in manual mode via vt100, DTR, or the front panel button if so configured.rw
Enumeration
.1.3.6.1.4.1.466.3.3.6
ty1250CfgNetDialTimeoutIn switched applications, time in seconds to wait for far end to answer before giving up, and possibly redialing.rw
INTEGER
.1.3.6.1.4.1.466.3.3.7
ty1250CfgNetNumRedialIn switched applications, number of times to redial if the call fails.rw
INTEGER
.1.3.6.1.4.1.466.3.3.8
ty1250CfgNetRedialDelayIn switched applications, delay in seconds between redial attempts.rw
INTEGER
.1.3.6.1.4.1.466.3.3.9
ty1250CfgNetDefNum2DialIn switched applications, default phone number to dial. Numbers and dashes are allowed.rw
DisplayString
.1.3.6.1.4.1.466.3.3.10
ty1250CfgNetTypeIndicates type of service purchased on the attached network line (DDS or SW56). Valid selections are dedicated (1) and switch56 (2).rw
Enumeration
.1.3.6.1.4.1.466.3.3.11
ty1250CfgNetBPVThresholdingAllows the user to turn on and off the BPV thresholding function. Valid values are thresholding_at_10E-4 (1) and disable-thresholding (2).rw
Enumeration
.1.3.6.1.4.1.466.3.3.12
ty1250CfgDteTable
OBJECT IDENTIFIER
.1.3.6.1.4.1.466.3.4
ty1250CfgDteTypeThe Dte channel type identifies the electrical specification of the interface. Read-only.ro
Enumeration
.1.3.6.1.4.1.466.3.4.1
ty1250CfgDteClockInvertClock Inversion, invert-dte-clock (2), can be used to solve out of phase timing problems on DTE link. normal-dte-clock (1) can be used in most cases.rw
Enumeration
.1.3.6.1.4.1.466.3.4.5
ty1250CfgDteTimingThe DTE channel Timing mode. Use loop2-timing (2) when in doubt.rw
Enumeration
.1.3.6.1.4.1.466.3.4.6
ty1250CfgDialTable
OBJECT IDENTIFIER
.1.3.6.1.4.1.466.3.5
ty1250CfgDialButtonIn switched applications, Enables/Disables the button on front of unit. This button can used to manual answer an incomming call, or dial out the default number. The valid values are enable-button (1) and disable-button (2).rw
Enumeration
.1.3.6.1.4.1.466.3.5.1
ty1250CfgDialDtrIn switched applications, Enables/Disables dialing on DTR signal transition. Valid values enable-dtr (1) and disable-dtr (2).rw
Enumeration
.1.3.6.1.4.1.466.3.5.2
ty1250CfgDialRtsDiscIn switched applications, Enables/Disables disconnecting on RTS signal transition. Valid values are enable-rts (1) and disable-rts (2).rw
Enumeration
.1.3.6.1.4.1.466.3.5.3
ty1250CfgDialRiIn switched applications, Enables/Disables incoming call notification to DTE via RI signal. Valid values are enable-ri (1) and disable-ri (2).rw
Enumeration
.1.3.6.1.4.1.466.3.5.4
ty1250CfgMaintTableThe Maintenance Port Configuration table contains parameters for the Maintenance ports on the 1250. The Terminal Port is Index=1; SLIP port is 2
SEQUENCE OF Ty1250CfgMaintEntry
.1.3.6.1.4.1.466.3.6
ty1250CfgMaintEntryMaintenance Port Configuration Object
Ty1250CfgMaintEntry
.1.3.6.1.4.1.466.3.6.1
ty1250CfgMaintIndexThe Maintenance port under consideration. On the 1250, the Terminal Port is Index=1; SLIP port is 2.ro
INTEGER
.1.3.6.1.4.1.466.3.6.1.1
ty1250CfgMaintModeThe Mode for this Maintenance Port. Values include ascii-vt100 (4), slip (7), and cslip (8).rw
Enumeration
.1.3.6.1.4.1.466.3.6.1.2
ty1250CfgMaintBaudBaud rate for this Maintenance port. Values are baud-2400 (2), baud-9600 (4), baud-19200 (5).rw
Enumeration
.1.3.6.1.4.1.466.3.6.1.3
ty1250CfgMaintDataBitsDatabits for this Maintenance port. Values are databits-7 (1) and databits-8 (2).rw
Enumeration
.1.3.6.1.4.1.466.3.6.1.4
ty1250CfgMaintStopBitsNumber of Stopbits for this Maintenance port. Values are stopbits-1 (1), stopbits-1-5 (2), and stopbits-2 (3).rw
Enumeration
.1.3.6.1.4.1.466.3.6.1.5
ty1250CfgMaintParityParity for this Maintenance port. Values are no-parity (1), odd-parity (2), even-parity (3).rw
Enumeration
.1.3.6.1.4.1.466.3.6.1.6
ty1250CfgMaintFlowCtrlFlow Control for this Maintenance port. Values are no-flow-control (1), software-flow-control (2), and hardware-flow-control (3).rw
Enumeration
.1.3.6.1.4.1.466.3.6.1.7
ty1250CfgSlipTable
OBJECT IDENTIFIER
.1.3.6.1.4.1.466.3.8
ty1250CfgSlipMyIPThe IP address for this node.rw
IpAddress
.1.3.6.1.4.1.466.3.8.1
ty1250CfgSlipPeerIPThe IP address for other end of slip connection.rw
IpAddress
.1.3.6.1.4.1.466.3.8.2
ty1250CfgSlipMaskThe IP Network Mask (eg 255.255.255.0) for the SLIP link.rw
IpAddress
.1.3.6.1.4.1.466.3.8.3
ty1250CfgSlipMaxMTUThe Maximum Transmission Unit is the size of the largest IP packet supported. This value should be set to the lowest value supported by any equipment in the transmission path. A size of 1006 (including header) is suggested.rw
INTEGER
.1.3.6.1.4.1.466.3.8.4
ty1250CallTable
OBJECT IDENTIFIER
.1.3.6.1.4.1.466.3.9
ty1250CallStatusThe call status is shown here.ro
Enumeration
.1.3.6.1.4.1.466.3.9.1
ty1250CallNumberThe last phone number dialed out.rw
DisplayString
.1.3.6.1.4.1.466.3.9.2
ty1250CallUpTimeNumber of seconds the call has been up.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.466.3.9.3
ty1250CallStateCall-related actions: a: Connect (initiate a call), b: Disconnect (terminate a call) c: Answer (answer an incoming call).rw
Enumeration
.1.3.6.1.4.1.466.3.9.4
ty1250DiagUnitTable
OBJECT IDENTIFIER
.1.3.6.1.4.1.466.3.10
ty1250DiagUnitLocLoopEnables the operator to control and examine the UNIT local loopback. This loopback occurs on all network ports transmit and receive logic. The unit will transmit DTE data out to the network as normal, and will also loop DTE data back to the DTE.rw
Enumeration
.1.3.6.1.4.1.466.3.10.1
ty1250DiagUnitResetEnables the operator to remotely reset the unit. Using this command will cause the unit to terminate all its connections and drop data.rw
Enumeration
.1.3.6.1.4.1.466.3.10.2
ty1250DiagNetTable
OBJECT IDENTIFIER
.1.3.6.1.4.1.466.3.11
ty1250DiagNetLineStatusThe Current status of the physical interface. Your network carrier can send Out-of-Service or Maintenance Mode codes.ro
Enumeration
.1.3.6.1.4.1.466.3.11.1
ty1250DiagNetLclLpbkEnables the operator to control and examine the network local loopback. This loopback occurs on the net side of the local transmit and receive logic. The unit continues to receive data from the network and also loops received data back to the network.rw
Enumeration
.1.3.6.1.4.1.466.3.11.2
ty1250DiagNetRmtLpbkEnables the operator to examine (ONLY) the status of network loopbacks placed by external equipment, such as your local CO. These loopbacks will loop received network data back out the network, disconnecting the DTE completely.ro
Enumeration
.1.3.6.1.4.1.466.3.11.3
ty1250DiagDteTable
OBJECT IDENTIFIER
.1.3.6.1.4.1.466.3.12
ty1250DiagDteSigRTSThe Dte Channel RTS signal. Values are rts-signal-on (1) and rts-signal-off (2).ro
Enumeration
.1.3.6.1.4.1.466.3.12.1
ty1250DiagDteSigDTRThe Dte Channel DTR signal. Values are dtr-signal-on (1) and dtr-signal-off (2).ro
Enumeration
.1.3.6.1.4.1.466.3.12.2
ty1250DiagDteLclLpbkThis selection displays the status or controls the Local DTE Channel Loopback for the selected channel. This is will loop DTE data back towards the DTE interface in addition to passing it on to the network.rw
Enumeration
.1.3.6.1.4.1.466.3.12.5
ty1250DiagDteV54LpbkThis selection displays the status of the DTE Channel V.54 Loopback for the channel. This loopback is initiated by the remote node, causing this node to loop data back to the remote node.ro
Enumeration
.1.3.6.1.4.1.466.3.12.6
ty1250DiagDteBerStateBERT test related actions: a: Starts a BERT test on a channel, b: Stops a BERT test on a channel, c: Inject Errors while the BERT test is running, d: Clears BERT test errors.rw
Enumeration
.1.3.6.1.4.1.466.3.12.7
ty1250DiagDteBerStatusDisplays the current BERT test sync status.ro
Enumeration
.1.3.6.1.4.1.466.3.12.8
ty1250DiagDteBerErrorsDisplays the number of errors detected in Bert Test.ro
Counter
.1.3.6.1.4.1.466.3.12.9
ty1250DiagDteBerErrSecDisplays the number of seconds containing errors in BERT Test.ro
Counter
.1.3.6.1.4.1.466.3.12.10
ty1250DiagDteBerTimeElapsElapsed time since BERT test was started or cleared.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.466.3.12.11
ty1250DiagDteBerResyncsDisplays the number of times BERT test has synched up on the pattern.ro
Counter
.1.3.6.1.4.1.466.3.12.12
ty1250DiagDteRmtV54LpbkThis selection controls the DTE Channel V.54 Remote Loopback. Transmit-code-enable (3) will cause the node to transmit a V.54 code to the remote node which will then loop received data back to this node. transmit-code-disable (4) will transmit the disable code.rw
Enumeration
.1.3.6.1.4.1.466.3.12.13
ty1250AlarmTypeThe type of alarms that are generated on the nodero
Enumeration
.1.3.6.1.4.1.466.3.13
ty1250CfgSnmpTable
OBJECT IDENTIFIER
.1.3.6.1.4.1.466.3.14
ty1250CfgSnmpManagerIPThe IP address for the SNMP manager to receive this node's TRAPs.rw
IpAddress
.1.3.6.1.4.1.466.3.14.1
ty1250StatsDteTable
OBJECT IDENTIFIER
.1.3.6.1.4.1.466.3.15
ty1250StatsDteTxByteCountThe statistic counting the number of bytes transmitted on the DTE channel.ro
INTEGER
.1.3.6.1.4.1.466.3.15.1
ty1250StatsDteRxByteCountThe statistic counting the number of bytes received on the DTE channel.ro
INTEGER
.1.3.6.1.4.1.466.3.15.2
ty1250StatsDteClearStatsAllows the user to zero out all the statistics in the DTE statistics table.rw
Enumeration
.1.3.6.1.4.1.466.3.15.3
ty1250StatsNetTable
OBJECT IDENTIFIER
.1.3.6.1.4.1.466.3.16
ty1250StatsNetLoopLengthThe statistic that estimates line attentuation on the network channel.ro
INTEGER
.1.3.6.1.4.1.466.3.16.1
ty1250StatsNetBpvCountThe statistic counting the number of BPV errors on the network channel.ro
INTEGER
.1.3.6.1.4.1.466.3.16.2
ty1250StatsNetTxByteCountThe statistic counting the number of bytes transmitted on the network channel.ro
INTEGER
.1.3.6.1.4.1.466.3.16.3
ty1250StatsNetRxByteCountThe statistic counting the number of bytes received on the network channel.ro
INTEGER
.1.3.6.1.4.1.466.3.16.4
ty1250StatsNetClearStatsAllows the user to zero out all the statistics in the network statistics table.rw
Enumeration
.1.3.6.1.4.1.466.3.16.5
ty1250CfgTelnetTable
OBJECT IDENTIFIER
.1.3.6.1.4.1.466.3.17
ty1250CfgTelnetEnableEnables/Disables the telnet feature. Valid values are enable-telnet (1) and disable-telnet (2).rw
Enumeration
.1.3.6.1.4.1.466.3.17.1
ty1250CfgTelnetAutoLogOutEnables/Disables the telnet auto-logout, logging out the user after a certain length of idle time. Valid values are autologout-at-15-minutes (1) and disable-autologout (2).rw
Enumeration
.1.3.6.1.4.1.466.3.17.2
TY1250I-MIB - SNMP MIB Reference | MIBs Explorer