TROPIC-SLOT-MIB
AI MIB Summary
The TROPIC-SLOT-MIB module provides SNMP access to monitor and manage the physical slot status, presence, and operational state of line cards within Tropic Networks hardware platforms. It exposes specific metrics regarding slot availability, hardware insertion events, and the operational readiness of individual chassis slots for fault isolation and inventory tracking.
The slot MIB.
Main OID:
tnSlotMibModule.1.3.6.1.4.1.7483.1.1.2.2.2.1
37
Objects
Active
Status
7
Dependencies
Imported Objects
Objects
37 total| Object Name |
|---|
tnSlotMibModuleThe slot MIB. MODULE-IDENTITY .1.3.6.1.4.1.7483.1.1.2.2.2.1 |
tnSlotConf OBJECT IDENTIFIER .1.3.6.1.4.1.7483.2.2.2.1.1 |
tnSlotGroups OBJECT IDENTIFIER .1.3.6.1.4.1.7483.2.2.2.1.1.1 |
tnSlotGroup. Unknown .1.3.6.1.4.1.7483.2.2.2.1.1.1.1 |
tnSlotResetGroup. Unknown .1.3.6.1.4.1.7483.2.2.2.1.1.1.2 |
tnSlotCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.7483.2.2.2.1.1.2 |
tnSlotCompliance. Unknown .1.3.6.1.4.1.7483.2.2.2.1.1.2.1 |
tnSlotObjs OBJECT IDENTIFIER .1.3.6.1.4.1.7483.2.2.2.1.2 |
tnSlotBasics OBJECT IDENTIFIER .1.3.6.1.4.1.7483.2.2.2.1.2.2 |
tnSlotTable. SEQUENCE OF TnSlotEntry .1.3.6.1.4.1.7483.2.2.2.1.2.2.1 |
tnSlotEntry. TnSlotEntry .1.3.6.1.4.1.7483.2.2.2.1.2.2.1.1 |
tnSlotIndex. TropicSlotIndexType (TROPIC-TC) .1.3.6.1.4.1.7483.2.2.2.1.2.2.1.1.1 |
tnSlotProgrammedTypeType of card to be provisioned in the given Slot.rw OBJECT IDENTIFIER .1.3.6.1.4.1.7483.2.2.2.1.2.2.1.1.2 |
tnSlotPresentTypeActual card present in the given slot.ro OBJECT IDENTIFIER .1.3.6.1.4.1.7483.2.2.2.1.2.2.1.1.3 |
tnSlotAdminState.rw TropicAdminStateType (TROPIC-TC) .1.3.6.1.4.1.7483.2.2.2.1.2.2.1.1.4 |
tnSlotOperationalState.ro TropicOperationalStateType (TROPIC-TC) .1.3.6.1.4.1.7483.2.2.2.1.2.2.1.1.5 |
tnSlotOperationalCapability.ro TropicOperationalCapabilityType (TROPIC-TC) .1.3.6.1.4.1.7483.2.2.2.1.2.2.1.1.6 |
tnSlotStateQualifier.ro TropicStateQualifierType (TROPIC-TC) .1.3.6.1.4.1.7483.2.2.2.1.2.2.1.1.7 |
tnSlotAlmProfName.rw OCTET STRING .1.3.6.1.4.1.7483.2.2.2.1.2.2.1.1.17 |
tnSlotMigrationTypeReplacement CardType for current existing card in the Slot.rw OBJECT IDENTIFIER .1.3.6.1.4.1.7483.2.2.2.1.2.2.1.1.18 |
tnSlotProgrammedSubTypeSubType of card to be provisioned in the given Slot.rw AluWdmSlotSubType .1.3.6.1.4.1.7483.2.2.2.1.2.2.1.1.19 |
tnSlotPresentSubTypeSubType of card present in the given slot.rw AluWdmSlotSubType .1.3.6.1.4.1.7483.2.2.2.1.2.2.1.1.20 |
tnSlotProgrammedGenericType.rw SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.7483.2.2.2.1.2.2.1.1.21 |
tnSlotPresentGenericType.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.7483.2.2.2.1.2.2.1.1.22 |
tnSlotProgrammedProductCode.rw SnmpAdminString .1.3.6.1.4.1.7483.2.2.2.1.2.2.1.1.23 |
tnSlotProductCodeSup.rw Enumeration .1.3.6.1.4.1.7483.2.2.2.1.2.2.1.1.24 |
tnSlotLifeCycleState.rw SnmpAdminString .1.3.6.1.4.1.7483.2.2.2.1.2.2.1.1.25 |
tnSlotDueDate.rw SnmpAdminString .1.3.6.1.4.1.7483.2.2.2.1.2.2.1.1.26 |
tnSlotInsertExtract.rw Enumeration .1.3.6.1.4.1.7483.2.2.2.1.2.2.1.1.27 |
tnSlotMigrationSubTypeReplacement SubType for current existing card in the slot.rw AluWdmSlotSubType .1.3.6.1.4.1.7483.2.2.2.1.2.2.1.1.28 |
tnSlotCustomerLifeCycleState.rw SnmpAdminString .1.3.6.1.4.1.7483.2.2.2.1.2.2.1.1.29 |
tnSlotKeyGraceEndTimeAfter the key mismatch is detected for the slot, grace period starts. Once the grace period has expired, the card is powered off. -1 will be reported if the grace period has expired.ro Integer32 .1.3.6.1.4.1.7483.2.2.2.1.2.2.1.1.30 |
tnSlotResetTable. SEQUENCE OF TnSlotResetEntry .1.3.6.1.4.1.7483.2.2.2.1.2.2.2 |
tnSlotResetEntry. TnSlotResetEntry .1.3.6.1.4.1.7483.2.2.2.1.2.2.2.1 |
tnSlotReset.rw TropicNewResetType (TROPIC-TC) .1.3.6.1.4.1.7483.2.2.2.1.2.2.2.1.1 |
tnSlotResetReason.ro Enumeration .1.3.6.1.4.1.7483.2.2.2.1.2.2.2.1.2 |
tnSlotResetTimeThe last reset time measured in total time ticks (seconds) from the year 1970. This is not supported on fan controllers.ro Unsigned32 .1.3.6.1.4.1.7483.2.2.2.1.2.2.2.1.3 |