TPT-BAY-MIB
AI MIB Summary
The TPT-BAY-MIB module enables monitoring of physical slot status and hardware configuration details on Trend Micro TippingPoint intrusion prevention systems. It provides granular visibility into bay-level hardware states, allowing administrators to track the operational status of installed security modules and expansion cards within the chassis.
Slot details on the device. Copyright (C) 2016 Trend Micro Incorporated. All Rights Reserved. Trend Micro makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Trend Micro shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. This document contains proprietary information, which is protected by copyright. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent of Trend Micro. The information is provided 'as is' without warranty of any kind and is subject to change without notice. The only warranties for Trend Micro products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. Trend Micro shall not be liable for technical or editorial errors or omissions contained herein. TippingPoint(R), the TippingPoint logo, and Digital Vaccine(R) are registered trademarks of Trend Micro. All other company and product names may be trademarks of their respective holders. All rights reserved. This document contains confidential information, trade secrets or both, which are the property of Trend Micro. No part of this documentation may be reproduced in any form or by any means or used to make any derivative work (such as translation, transformation, or adaptation) without written permission from Trend Micro or one of its subsidiaries. All other company and product names may be trademarks of their respective holders.
Main OID:
tpt_slot_objs.1.3.6.1.4.1.10734.3.3.2.17
13
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
13 total| Object Name |
|---|
tpt_slot_objsSlot details on the device. Copyright (C) 2016 Trend Micro Incorporated. All Rights Reserved. Trend Micro makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Trend Micro shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. This document contains proprietary information, which is protected by copyright. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent of Trend Micro. The information is provided 'as is' without warranty of any kind and is subject to change without notice. The only warranties for Trend Micro products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. Trend Micro shall not be liable for technical or editorial errors or omissions contained herein. TippingPoint(R), the TippingPoint logo, and Digital Vaccine(R) are registered trademarks of Trend Micro. All other company and product names may be trademarks of their respective holders. All rights reserved. This document contains confidential information, trade secrets or both, which are the property of Trend Micro. No part of this documentation may be reproduced in any form or by any means or used to make any derivative work (such as translation, transformation, or adaptation) without written permission from Trend Micro or one of its subsidiaries. All other company and product names may be trademarks of their respective holders. MODULE-IDENTITY .1.3.6.1.4.1.10734.3.3.2.17 |
slotTempTableTable of slots on the device. SEQUENCE OF SlotTempEntry .1.3.6.1.4.1.10734.3.3.2.17.1 |
slotTempEntryAn entry in the slot table. Rows cannot be created or deleted. SlotTempEntry .1.3.6.1.4.1.10734.3.3.2.17.1.1 |
slotTempIndexIndex into the slot table, starting with 1. Unsigned32 .1.3.6.1.4.1.10734.3.3.2.17.1.1.1 |
slotNameString description of the name of slot.ro OCTET STRING .1.3.6.1.4.1.10734.3.3.2.17.1.1.2 |
slotModuleNameString description of the type of module in slot.ro OCTET STRING .1.3.6.1.4.1.10734.3.3.2.17.1.1.3 |
slotStatusstatus of this slotro SlotStatus .1.3.6.1.4.1.10734.3.3.2.17.1.1.4 |
slotModuleSerialNumString description of the serial number of the module in the slot.ro OCTET STRING .1.3.6.1.4.1.10734.3.3.2.17.1.1.5 |
slotModuleTypeType of module present in the slot. This is applicable mainly for the newer devices like 6100 and above, which have multiple I/O slots. For older systems like 5100 which don't have slots, the module type would be the device model number.ro SlotModuleType .1.3.6.1.4.1.10734.3.3.2.17.1.1.6 |
tptSlotChangeNotifyNotification: Module was inserted on this device NOTIFICATION-TYPE .1.3.6.1.4.1.10734.3.3.3.0.54 |
tptSlotDeviceIDThe unique identifier of the device sending this notification.ro OCTET STRING .1.3.6.1.4.1.10734.3.3.3.1.281 |
tptSlotIDThe slot index which is sending this notification.ro Unsigned32 .1.3.6.1.4.1.10734.3.3.3.1.282 |
tptSlotEventThe event occuring in the slot which is sending this notification.ro SlotEvent .1.3.6.1.4.1.10734.3.3.3.1.283 |