TN-SYNCE-MIB
AI MIB Summary
The TN-SYNCE-MIB module enables the monitoring and configuration of Synchronous Ethernet (SyncE) clock synchronization parameters, including clock quality levels, traceability paths, and synchronization status, on network equipment supporting Time-Network synchronization. It facilitates the management of SyncE interfaces and the retrieval of performance metrics essential for maintaining timing integrity in carrier-grade transport networks.
The mib provides functionalities for managing SyncE.
Main OID:
tnSynceMIB.1.3.6.1.4.1.868.2.5.122
41
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
41 total| Object Name |
|---|
tnSynceMIBThe mib provides functionalities for managing SyncE. MODULE-IDENTITY .1.3.6.1.4.1.868.2.5.122 |
tnSynce OBJECT IDENTIFIER .1.3.6.1.4.1.868.2.5.122.1 |
tnSyncETableTable to manage SyncE for each device. SEQUENCE OF TnSyncEEntry .1.3.6.1.4.1.868.2.5.122.1.1 |
tnSyncEEntryAn entry containing SyncE for each device. TnSyncEEntry .1.3.6.1.4.1.868.2.5.122.1.1.1 |
tnSyncEStateModeClock source selection mode manual: Selector is manually set to the chosen clock source selected: Selector is manually set to the pt. selected clock source (not possible in unlocked mode) nonrevertive: Selector is automatically selecting the best clock source - non revertively revertive: Selector is automatically selecting the best clock source - revertively holdover: Selector is forced in holdover freerun: Selector is forced in free runrw Enumeration .1.3.6.1.4.1.868.2.5.122.1.1.1.1 |
tnSyncEStateWTRTimeWTR (Wait-to-Restore) time in minutes(0-12 min) '0' is disablerw INTEGER .1.3.6.1.4.1.868.2.5.122.1.1.1.2 |
tnSyncEStateSSMHoldOverSynchronization Status Messaging Hold Over. Hold Over is switching over to Local Reference Clock if primary and secondary nodes fail prc = Primary Reference Clock eec2 Ethernet Equipment Clock 1.544 kpbs eec1 Ethernet Equipment Clock 2.048 kpbsrw Enumeration .1.3.6.1.4.1.868.2.5.122.1.1.1.3 |
tnSyncEStateSSMFreeRunSynchronization Status Messaging Free Runrw Enumeration .1.3.6.1.4.1.868.2.5.122.1.1.1.4 |
tnSyncEAlarmStateLOLAlarm State Loss of Lock (LOL)ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.868.2.5.122.1.1.1.5 |
tnSyncEAlarmStateDHOLDAlarm State Digital Hold (DHOLD)ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.868.2.5.122.1.1.1.6 |
tnSyncESelStateClock Selection State Note: prelock2, prelock and lossoflock are not available on all productsro Enumeration .1.3.6.1.4.1.868.2.5.122.1.1.1.7 |
tnSyncEClkSrcClock Sourcerw INTEGER .1.3.6.1.4.1.868.2.5.122.1.1.1.8 |
tnSyncEClkSourceTableTable of SyncE ClkSource SEQUENCE OF TnSyncEClkSourceEntry .1.3.6.1.4.1.868.2.5.122.1.2 |
tnSyncEClkSourceEntryAn entry in the table,tnSyncEClkSourceTable TnSyncEClkSourceEntry .1.3.6.1.4.1.868.2.5.122.1.2.1 |
tnSyncEClkSourceIndexIndex of SyncE ClkSource table. 1-SYNCE_NOMINATED_MAXro INTEGER .1.3.6.1.4.1.868.2.5.122.1.2.1.1 |
tnSyncEConfPortSyncE Configuration Port. 0-MAX_PORT. a port value of 0 means not nominatedrw INTEGER .1.3.6.1.4.1.868.2.5.122.1.2.1.2 |
tnSyncEConfSSMOverwriteClock source SSM overwriterw Enumeration .1.3.6.1.4.1.868.2.5.122.1.2.1.3 |
tnSyncEConfHoldOffThe hold off timer value in 100 ms. Valid values are: 0 for disable. The range 3-18. The value 100 for testrw INTEGER .1.3.6.1.4.1.868.2.5.122.1.2.1.4 |
tnSyncEConfANEGAuto Negotiate : 1000BaseT ANEG mode slave: Activate prefer slave negotiation master: Activate prefer master negotiation forced: Activate forced slave negotiation.rw Enumeration .1.3.6.1.4.1.868.2.5.122.1.2.1.5 |
tnSyncEPriorityClock source priority setting. (SYNCE_PRIORITY_MAX = CLOCK_INPUT_MAX = 2 i.e. 0,1)rw INTEGER .1.3.6.1.4.1.868.2.5.122.1.2.1.6 |
tnSyncEClearSyncE Clear.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.868.2.5.122.1.2.1.7 |
tnSyncEAlarmStateLOCSSyncE Alarm State LOCS.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.868.2.5.122.1.2.1.8 |
tnSyncEAlarmStateSSMSyncE Alarm State SSM.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.868.2.5.122.1.2.1.9 |
tnSyncEAlarmStateWTRSyncE Alarm State WRT.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.868.2.5.122.1.2.1.10 |
tnSyncENominatedSyncE Nominated.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.868.2.5.122.1.2.1.11 |
tnSyncEPortTableTable of SyncEPort. SEQUENCE OF TnSyncEPortEntry .1.3.6.1.4.1.868.2.5.122.1.3 |
tnSyncEPortEntryAn entry containing tnSynce. TnSyncEPortEntry .1.3.6.1.4.1.868.2.5.122.1.3.1 |
tnSyncEStatePortIndexSyncE Port index, 0-SYNCE_PORT_COUNT.ro INTEGER .1.3.6.1.4.1.868.2.5.122.1.3.1.1 |
tnSyncEStateTxSSMSyncE Transmit SSM State.ro Enumeration .1.3.6.1.4.1.868.2.5.122.1.3.1.2 |
tnSyncEStateRxSSMSyncE Receive SSM State.ro Enumeration .1.3.6.1.4.1.868.2.5.122.1.3.1.3 |
tnSyncEStateSSMModeSyncE SSM Mode.ro Enumeration .1.3.6.1.4.1.868.2.5.122.1.3.1.4 |
tnSyncESSMEnabledSyncE SSM Enabled.rw Enumeration .1.3.6.1.4.1.868.2.5.122.1.3.1.5 |
tnSyncEExtTableTable of SyncE External I/O SEQUENCE OF TnSyncEExtEntry .1.3.6.1.4.1.868.2.5.122.1.4 |
tnSyncEExtEntryAn entry in the table,tnSyncEExtTable TnSyncEExtEntry .1.3.6.1.4.1.868.2.5.122.1.4.1 |
tnSyncEExtInStateExternal I/O in direction state.rw Enumeration .1.3.6.1.4.1.868.2.5.122.1.4.1.1 |
tnSyncEExtOutStateExternal I/O out direction state.rw Enumeration .1.3.6.1.4.1.868.2.5.122.1.4.1.2 |
tnSyncEExtInFreqExternal I/O in direction frequency 8k-25Mhz table of values.rw Enumeration .1.3.6.1.4.1.868.2.5.122.1.4.1.3 |
tnSyncEExtOutFreqExternal I/O out direction frequency 8k-25Mhz table of valuesrw Enumeration .1.3.6.1.4.1.868.2.5.122.1.4.1.4 |
tnSyncEExtImpedanceExternal I/O Impedance.rw Enumeration .1.3.6.1.4.1.868.2.5.122.1.4.1.5 |
tnSyncEActualInFreqThe actual input frequency in Hz.ro INTEGER .1.3.6.1.4.1.868.2.5.122.1.4.1.6 |
tnSyncEActualOutFreqThe actual output frequency in Hz. If output state is disabled set to 0ro INTEGER .1.3.6.1.4.1.868.2.5.122.1.4.1.7 |