Home/Catalog/TN-SYNCE-MIB

TN-SYNCE-MIB

AI MIB Summary

The TN-SYNCE-MIB module enables the monitoring and configuration of Synchronous Ethernet (SyncE) clock synchronization parameters, including clock quality levels, traceability paths, and synchronization status, on network equipment supporting Time-Network synchronization. It facilitates the management of SyncE interfaces and the retrieval of performance metrics essential for maintaining timing integrity in carrier-grade transport networks.

The mib provides functionalities for managing SyncE.
Main OID:
tnSynceMIB.1.3.6.1.4.1.868.2.5.122
41
Objects
Active
Status
3
Dependencies

Imported Objects

Objects

41 total
Object Name
tnSynceMIBThe mib provides functionalities for managing SyncE.
MODULE-IDENTITY
.1.3.6.1.4.1.868.2.5.122
tnSynce
OBJECT IDENTIFIER
.1.3.6.1.4.1.868.2.5.122.1
tnSyncETableTable to manage SyncE for each device.
SEQUENCE OF TnSyncEEntry
.1.3.6.1.4.1.868.2.5.122.1.1
tnSyncEEntryAn entry containing SyncE for each device.
TnSyncEEntry
.1.3.6.1.4.1.868.2.5.122.1.1.1
tnSyncEStateModeClock source selection mode manual: Selector is manually set to the chosen clock source selected: Selector is manually set to the pt. selected clock source (not possible in unlocked mode) nonrevertive: Selector is automatically selecting the best clock source - non revertively revertive: Selector is automatically selecting the best clock source - revertively holdover: Selector is forced in holdover freerun: Selector is forced in free runrw
Enumeration
.1.3.6.1.4.1.868.2.5.122.1.1.1.1
tnSyncEStateWTRTimeWTR (Wait-to-Restore) time in minutes(0-12 min) '0' is disablerw
INTEGER
.1.3.6.1.4.1.868.2.5.122.1.1.1.2
tnSyncEStateSSMHoldOverSynchronization Status Messaging Hold Over. Hold Over is switching over to Local Reference Clock if primary and secondary nodes fail prc = Primary Reference Clock eec2 Ethernet Equipment Clock 1.544 kpbs eec1 Ethernet Equipment Clock 2.048 kpbsrw
Enumeration
.1.3.6.1.4.1.868.2.5.122.1.1.1.3
tnSyncEStateSSMFreeRunSynchronization Status Messaging Free Runrw
Enumeration
.1.3.6.1.4.1.868.2.5.122.1.1.1.4
tnSyncEAlarmStateLOLAlarm State Loss of Lock (LOL)ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.868.2.5.122.1.1.1.5
tnSyncEAlarmStateDHOLDAlarm State Digital Hold (DHOLD)ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.868.2.5.122.1.1.1.6
tnSyncESelStateClock Selection State Note: prelock2, prelock and lossoflock are not available on all productsro
Enumeration
.1.3.6.1.4.1.868.2.5.122.1.1.1.7
tnSyncEClkSrcClock Sourcerw
INTEGER
.1.3.6.1.4.1.868.2.5.122.1.1.1.8
tnSyncEClkSourceTableTable of SyncE ClkSource
SEQUENCE OF TnSyncEClkSourceEntry
.1.3.6.1.4.1.868.2.5.122.1.2
tnSyncEClkSourceEntryAn entry in the table,tnSyncEClkSourceTable
TnSyncEClkSourceEntry
.1.3.6.1.4.1.868.2.5.122.1.2.1
tnSyncEClkSourceIndexIndex of SyncE ClkSource table. 1-SYNCE_NOMINATED_MAXro
INTEGER
.1.3.6.1.4.1.868.2.5.122.1.2.1.1
tnSyncEConfPortSyncE Configuration Port. 0-MAX_PORT. a port value of 0 means not nominatedrw
INTEGER
.1.3.6.1.4.1.868.2.5.122.1.2.1.2
tnSyncEConfSSMOverwriteClock source SSM overwriterw
Enumeration
.1.3.6.1.4.1.868.2.5.122.1.2.1.3
tnSyncEConfHoldOffThe hold off timer value in 100 ms. Valid values are: 0 for disable. The range 3-18. The value 100 for testrw
INTEGER
.1.3.6.1.4.1.868.2.5.122.1.2.1.4
tnSyncEConfANEGAuto Negotiate : 1000BaseT ANEG mode slave: Activate prefer slave negotiation master: Activate prefer master negotiation forced: Activate forced slave negotiation.rw
Enumeration
.1.3.6.1.4.1.868.2.5.122.1.2.1.5
tnSyncEPriorityClock source priority setting. (SYNCE_PRIORITY_MAX = CLOCK_INPUT_MAX = 2 i.e. 0,1)rw
INTEGER
.1.3.6.1.4.1.868.2.5.122.1.2.1.6
tnSyncEClearSyncE Clear.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.868.2.5.122.1.2.1.7
tnSyncEAlarmStateLOCSSyncE Alarm State LOCS.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.868.2.5.122.1.2.1.8
tnSyncEAlarmStateSSMSyncE Alarm State SSM.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.868.2.5.122.1.2.1.9
tnSyncEAlarmStateWTRSyncE Alarm State WRT.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.868.2.5.122.1.2.1.10
tnSyncENominatedSyncE Nominated.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.868.2.5.122.1.2.1.11
tnSyncEPortTableTable of SyncEPort.
SEQUENCE OF TnSyncEPortEntry
.1.3.6.1.4.1.868.2.5.122.1.3
tnSyncEPortEntryAn entry containing tnSynce.
TnSyncEPortEntry
.1.3.6.1.4.1.868.2.5.122.1.3.1
tnSyncEStatePortIndexSyncE Port index, 0-SYNCE_PORT_COUNT.ro
INTEGER
.1.3.6.1.4.1.868.2.5.122.1.3.1.1
tnSyncEStateTxSSMSyncE Transmit SSM State.ro
Enumeration
.1.3.6.1.4.1.868.2.5.122.1.3.1.2
tnSyncEStateRxSSMSyncE Receive SSM State.ro
Enumeration
.1.3.6.1.4.1.868.2.5.122.1.3.1.3
tnSyncEStateSSMModeSyncE SSM Mode.ro
Enumeration
.1.3.6.1.4.1.868.2.5.122.1.3.1.4
tnSyncESSMEnabledSyncE SSM Enabled.rw
Enumeration
.1.3.6.1.4.1.868.2.5.122.1.3.1.5
tnSyncEExtTableTable of SyncE External I/O
SEQUENCE OF TnSyncEExtEntry
.1.3.6.1.4.1.868.2.5.122.1.4
tnSyncEExtEntryAn entry in the table,tnSyncEExtTable
TnSyncEExtEntry
.1.3.6.1.4.1.868.2.5.122.1.4.1
tnSyncEExtInStateExternal I/O in direction state.rw
Enumeration
.1.3.6.1.4.1.868.2.5.122.1.4.1.1
tnSyncEExtOutStateExternal I/O out direction state.rw
Enumeration
.1.3.6.1.4.1.868.2.5.122.1.4.1.2
tnSyncEExtInFreqExternal I/O in direction frequency 8k-25Mhz table of values.rw
Enumeration
.1.3.6.1.4.1.868.2.5.122.1.4.1.3
tnSyncEExtOutFreqExternal I/O out direction frequency 8k-25Mhz table of valuesrw
Enumeration
.1.3.6.1.4.1.868.2.5.122.1.4.1.4
tnSyncEExtImpedanceExternal I/O Impedance.rw
Enumeration
.1.3.6.1.4.1.868.2.5.122.1.4.1.5
tnSyncEActualInFreqThe actual input frequency in Hz.ro
INTEGER
.1.3.6.1.4.1.868.2.5.122.1.4.1.6
tnSyncEActualOutFreqThe actual output frequency in Hz. If output state is disabled set to 0ro
INTEGER
.1.3.6.1.4.1.868.2.5.122.1.4.1.7

More MIBs from Transition

Browse all TransitionMIBs →
MCC16-MIB

SNMP MIB module

1253 objects→
TN-MPLS-MIB

The TN-MPLS-MIB module enables the monitoring and configuration of Multiprotocol Label Switching (MPLS) parameters, including label bindings, forwarding equivalence classes, and tunnel states, on Nokia (formerly Alcatel-Lucent) Service Router and IP/MPLS network devices.

452 objects→
TNI-MIB

Standard SNMP MIB module defining data structures for TNI-MIB.

445 objects→
TN-CES-MIB

The TN-CES-MIB module enables monitoring and management of Circuit Emulation Service (CES) sessions on network equipment, specifically tracking performance metrics such as session status, packet loss, jitter, and synchronization errors for T1/E1 circuit emulation over packet-switched networks.

282 objects→
TN-LLDP-MIB

The TN-LLDP-MIB module enables monitoring and management of Link Layer Discovery Protocol (LLDP) neighbor discovery data, including system identification, port descriptions, and TLV (Type-Length-Value) attributes, on Trellix (formerly McAfee) network infrastructure devices. This private MIB extension facilitates the collection of LLDP session states and neighbor topology information for network inventory and connectivity verification.

196 objects→
TN-DHCP-SERVER-MIB

The TN-DHCP-SERVER-MIB enables monitoring and management of Dynamic Host Configuration Protocol server configurations, lease states, and address pool utilization on Tanaza network infrastructure devices. This module provides visibility into DHCP scope assignments, client binding tables, and server operational status to facilitate network address administration.

168 objects→