TIMETRA-PXC-MIB
The TIMETRA-PXC-MIB enables SNMP-based provisioning and monitoring of Port Cross-Connect (PXC) components on Nokia SR OS (SROS) routers, specifically managing the configuration and status of internal switching fabric paths that interconnect line card ports.
Imported Objects
Objects
39 total| Object Name |
|---|
timetraPxcMIBModuleThis document is the SNMP MIB module to manage and provision the
Port Cross-Connect (PXC) components of the Nokia SROS
device.
Copyright (c) 2015-2016 Nokia. All rights reserved.
Reproduction of this document is authorized on the condition that
the foregoing copyright notice is included.
This SNMP MIB module (Specification) embodies Nokia's
proprietary intellectual property. Nokia retains all
title and ownership in the Specification, including any
revisions.
Nokia grants all interested parties a non-exclusive
license to use and distribute an unmodified copy of this
Specification in connection with management of Nokia products,
and without fee, provided this copyright notice and license
appear on all copies.
This Specification is supplied `as is', and Nokia makes
no warranty, either express or implied, as to the use,
operation, condition, or performance of the Specification. MODULE-IDENTITY .1.3.6.1.4.1.6527.1.1.3.105 |
tmnxPxcConformance OBJECT IDENTIFIER .1.3.6.1.4.1.6527.3.1.1.105 |
tmnxPxcCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.6527.3.1.1.105.1 |
tmnxPxcGroups OBJECT IDENTIFIER .1.3.6.1.4.1.6527.3.1.1.105.2 |
tmnxPxcV14v0Groups OBJECT IDENTIFIER .1.3.6.1.4.1.6527.3.1.1.105.2.1 |
tmnxPxcObjs OBJECT IDENTIFIER .1.3.6.1.4.1.6527.3.1.2.105 |
tmnxPxcConfigTimestamps OBJECT IDENTIFIER .1.3.6.1.4.1.6527.3.1.2.105.1 |
tmnxPxcTableLastChangedThe value of tmnxPxcTableLastChanged indicates the time, since
system startup, when tmnxPxcTable last changed configuration.ro TimeStamp (SNMPv2-TC) .1.3.6.1.4.1.6527.3.1.2.105.1.1 |
tmnxFpeTableLastChangedThe value of tmnxFpeTableLastChanged indicates the time, since
system startup, when tmnxFpeTable last changed configuration.ro TimeStamp (SNMPv2-TC) .1.3.6.1.4.1.6527.3.1.2.105.1.2 |
tmnxPxcConfigurations OBJECT IDENTIFIER .1.3.6.1.4.1.6527.3.1.2.105.2 |
tmnxPxcTableThe tmnxPxcTable contains the Port Cross-Connect (PXC)
configuration information.
A PXC is a physical port which is internally looped. Two logical
sub-ports are created under the PXC. These logical ports are used
to create two paths within the loop; one upstream path, and one
downstream path. SEQUENCE OF TmnxPxcEntry .1.3.6.1.4.1.6527.3.1.2.105.2.1 |
tmnxPxcEntryThe tmnxPxcEntry consists of configurable objects for a given PXC. TmnxPxcEntry .1.3.6.1.4.1.6527.3.1.2.105.2.1.1 |
tmnxPxcIdThe value of tmnxPxcId specifies the unique identifier of this PXC. Unsigned32 .1.3.6.1.4.1.6527.3.1.2.105.2.1.1.1 |
tmnxPxcRowStatusThe value of tmnxPxcRowStatus specifies the row status. It allows the
creation and deletion of PXC entries.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.6527.3.1.2.105.2.1.1.2 |
tmnxPxcLastChangedThe value of tmnxPxcLastChanged indicates the time, since system
startup, that the configuration of this PXC entry was created or
modified.ro TimeStamp (SNMPv2-TC) .1.3.6.1.4.1.6527.3.1.2.105.2.1.1.3 |
tmnxPxcAdminStateThe value of tmnxPxcAdminState specifies the administrative state for
this PXC entry.rw TmnxAdminState (TIMETRA-TC-MIB) .1.3.6.1.4.1.6527.3.1.2.105.2.1.1.4 |
tmnxPxcOperStateThe value of tmnxPxcOperState indicates the operational state of this
PXC entry.ro TmnxOperState (TIMETRA-TC-MIB) .1.3.6.1.4.1.6527.3.1.2.105.2.1.1.5 |
tmnxPxcPortIdThe value of tmnxPxcPortId specifies the port identifier of the port
associated with this PXC entry.
A value of '1e000000'H indicates this object has not been configured.
When this object is configured, two logical sub-ports are automatically
created in tmnxPortTable. These logical sub-ports are used
to create two paths within the loop; one upstream path, and one
downstream path. These sub-ports are destroyed when either this PXC
row is destroyed, this object is de-provisioned.rw TmnxPortID (TIMETRA-TC-MIB) .1.3.6.1.4.1.6527.3.1.2.105.2.1.1.6 |
tmnxPxcDescriptionThe value of tmnxPxcDescription specifies the description of this PXC
entry.
An empty string indicates this object has not been configured.rw TItemDescription (TIMETRA-TC-MIB) .1.3.6.1.4.1.6527.3.1.2.105.2.1.1.7 |
tmnxFpeTableThe tmnxFpeTable contains the Forward Path Extension (FPE)
configuration information to provide cross-connect infrastructure
to stitch traffic between external PW and the PW port. SEQUENCE OF TmnxFpeEntry .1.3.6.1.4.1.6527.3.1.2.105.2.2 |
tmnxFpeEntryThe tmnxFpeEntry consists of configurable objects for a given FPE. TmnxFpeEntry .1.3.6.1.4.1.6527.3.1.2.105.2.2.1 |
tmnxFpeIdThe value of tmnxFpeId specifies the unique identifier of this entry. Unsigned32 .1.3.6.1.4.1.6527.3.1.2.105.2.2.1.1 |
tmnxFpeRowStatusThe value of tmnxFpeRowStatus specifies the row status. It allows the
creation and deletion of entries.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.6527.3.1.2.105.2.2.1.2 |
tmnxFpeLastChangedThe value of tmnxFpeLastChanged indicates the time, since system
startup, that the configuration of this entry was created or
modified.ro TimeStamp (SNMPv2-TC) .1.3.6.1.4.1.6527.3.1.2.105.2.2.1.3 |
tmnxFpeDescriptionThe value of tmnxFpeDescription specifies the description of this
entry.rw TItemDescription (TIMETRA-TC-MIB) .1.3.6.1.4.1.6527.3.1.2.105.2.2.1.4 |
tmnxFpePxcIdThe value of tmnxFpePxcId specifies the cross connect port identifier
associated with this entry.
An 'inconsistentValue' error is returned if tmnxFpeXaLagId is set
to non-default and tmnxFpePxcId is set to non-default.
An 'inconsistentValue' error is returned if tmnxFpeXbLagId is set
to non-default and tmnxFpePxcId is set to non-default.rw Unsigned32 (0|1..64) .1.3.6.1.4.1.6527.3.1.2.105.2.2.1.5 |
tmnxFpeXaLagIdThe value of tmnxFpeXaLagId specifies the LAG identifier A
value associated with this entry.
An 'inconsistentValue' error is returned if tmnxFpeXaLagId is set
to non-default and tmnxFpeXbLagId is set to default.
An 'inconsistentValue' error is returned if tmnxFpeXaLagId is set
to non-default and tmnxFpePxcId is set to non-default.
An 'inconsistentValue' error is returned if tmnxFpeXbLagId is set
to non-default and tmnxFpePxcId is set to non-default.rw LAGInterfaceNumberOrZero .1.3.6.1.4.1.6527.3.1.2.105.2.2.1.6 |
tmnxFpeXbLagIdThe value of tmnxFpeXbLagId specifies the LAG identifier B
value associated with this entry.
An 'inconsistentValue' error is returned if tmnxFpeXaLagId is set
to non-default and tmnxFpeXbLagId is set to default.
An 'inconsistentValue' error is returned if tmnxFpeXaLagId is set
to non-default and tmnxFpePxcId is set to non-default.
An 'inconsistentValue' error is returned if tmnxFpeXbLagId is set
to non-default and tmnxFpePxcId is set to non-default.rw LAGInterfaceNumberOrZero .1.3.6.1.4.1.6527.3.1.2.105.2.2.1.7 |
tmnxFpePwPortThe value of tmnxFpePwPort specifies whether this Forward Path
Extension (FPE) will be used to setup FPE PW cross-connect.
An 'inconsistentValue' error is returned if tmnxFpePwPort is set
to non-default when tmnxFpeVxlanTermination is set to non-default.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.6527.3.1.2.105.2.2.1.8 |
tmnxFpeVxlanTerminationThe value of tmnxFpeVxlanTermination specifies whether this Forward
Path Extension (FPE) will be used to terminate VXLAN.
An 'inconsistentValue' error is returned if tmnxFpePwPort is set
to non-default when tmnxFpeVxlanTermination is set to non-default.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.6527.3.1.2.105.2.2.1.9 |
tmnxFpeVxlanOperStatusThe value of tmnxFpeVxlanOperStatus indicates the operating
status of vxlan.ro Enumeration .1.3.6.1.4.1.6527.3.1.2.105.2.2.1.10 |
tmnxFpePwPortOperStatusThe value of tmnxFpePwPortOperStatus indicates the operating status of
the pw port.ro Enumeration .1.3.6.1.4.1.6527.3.1.2.105.2.2.1.11 |
tmnxFpeSdpObjs OBJECT IDENTIFIER .1.3.6.1.4.1.6527.3.1.2.105.2.3 |
tmnxFpeSdpIdRngStartThe value of tmnxFpeSdpIdRngStart specifies the start range of the
sdp-id used by the FPE.rw SdpId (TIMETRA-SERV-MIB) .1.3.6.1.4.1.6527.3.1.2.105.2.3.1 |
tmnxFpeSdpIdRngEndThe value of tmnxFpeSdpIdRngEnd specifies the end range of the sdp-id
used by the FPE.rw SdpId (TIMETRA-SERV-MIB) .1.3.6.1.4.1.6527.3.1.2.105.2.3.2 |
tmnxPxcStatistics OBJECT IDENTIFIER .1.3.6.1.4.1.6527.3.1.2.105.3 |
tmnxPxcNotifyObjects OBJECT IDENTIFIER .1.3.6.1.4.1.6527.3.1.2.105.4 |
tmnxPxcNotifyPrefix OBJECT IDENTIFIER .1.3.6.1.4.1.6527.3.1.3.105 |
tmnxPxcNotification OBJECT IDENTIFIER .1.3.6.1.4.1.6527.3.1.3.105.0 |
More MIBs from Nokia
Browse all NokiaMIBs →The TIMETRA-LDP-NG-MIB enables monitoring and configuration of Nokia SR OS (SROS) Label Distribution Protocol Next Generation features, specifically tracking LDP session states, neighbor adjacencies, and label distribution statistics for MPLS traffic engineering.
The TIMETRA-TC-MIB defines proprietary SNMP textual conventions required for the Nokia SROS (Service Router Operating System) to standardize data types for monitoring interface states, traffic counters, and system resource metrics. These definitions serve as the foundational data structures for all TIMETRA-based management applications, ensuring consistent interpretation of telemetry and configuration parameters across Nokia routing platforms.
The TIMETRA-LOG-MIB enables SNMP-based configuration and monitoring of logging utility parameters, event generation rules, and log buffer states on Nokia SR OS (SROS) routers. It facilitates the retrieval of system log severity levels, destination settings, and buffer utilization metrics for centralized network event management.
The TIMETRA-OAM-PM-MIB enables SNMP-based monitoring of Service OAM performance metrics, including packet loss, latency, and jitter counters, on Nokia SR OS (SROS) routers. This proprietary module provides granular visibility into the operational health and quality of service for Layer 2 and Layer 3 Ethernet services.
The TIMETRA-GMPLS-MIB enables SNMP-based provisioning and monitoring of Generalized Multi-Protocol Label Switching (GMPLS) control plane parameters, including label distribution, tunnel signaling states, and resource reservation objects, specifically on Nokia SR OS (formerly TiMOS) routers. This module facilitates the management of GMPLS-specific extensions such as wavelength, fiber, and time-division multiplexing (TDM) link attributes across Nokia's service router hardware.
ALU-MICROWAVE-MIB enables SNMP-based provisioning and monitoring of microwave radio components on Nokia 7xxx series transport devices, specifically tracking link status, signal quality metrics (such as SNR and BER), and interface operational states. This proprietary module facilitates the management of microwave-specific parameters including frequency allocation, modulation schemes, and alarm conditions for point-to-point and point-to-multipoint wireless backhaul links.