Home/Catalog/TIMETRA-PTP-MIB

TIMETRA-PTP-MIB

AI MIB Summary

The TIMETRA-PTP-MIB enables SNMP-based provisioning and monitoring of IEEE 1588-2008 Precision Time Protocol (PTP) components on Alcatel-Lucent Service Router Operating System (SROS) platforms. It facilitates the management of PTP clock synchronization states, grandmaster selection, and boundary clock configurations to ensure precise time distribution across the network.

This document is the SNMP MIB module to manage and provision the Precision Time Protocol (PTP) components of the Alcatel-Lucent SROS device as defined in the IEEE Standard for a Precision Clock Synchronization Protocol for Networked Measurement and Control Systems (IEEE Std 1588-2008). Copyright (c) 2011-2014 Alcatel-Lucent. All rights reserved. Reproduction of this document is authorized on the condition that the foregoing copyright notice is included. This SNMP MIB module (Specification) embodies Alcatel-Lucent's proprietary intellectual property. Alcatel-Lucent retains all title and ownership in the Specification, including any revisions. Alcatel-Lucent grants all interested parties a non-exclusive license to use and distribute an unmodified copy of this Specification in connection with management of Alcatel-Lucent products, and without fee, provided this copyright notice and license appear on all copies. This Specification is supplied 'as is', and Alcatel-Lucent makes no warranty, either express or implied, as to the use, operation, condition, or performance of the Specification.
Main OID:
timetraPtpMIBModule.1.3.6.1.4.1.6527.1.1.3.74
189
Objects
Active
Status
9
Dependencies

Imported Objects

Objects

189 total
Object Name
timetraPtpMIBModule
MODULE-IDENTITY
.1.3.6.1.4.1.6527.1.1.3.74
tmnxPtp1588Conformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.6527.3.1.1.74
tmnxPtp1588Compliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.6527.3.1.1.74.1
tmnxPtp1588Groups
OBJECT IDENTIFIER
.1.3.6.1.4.1.6527.3.1.1.74.2
tmnxPtpV9v0Groups
OBJECT IDENTIFIER
.1.3.6.1.4.1.6527.3.1.1.74.2.1
tmnxPtpV10v0Groups
OBJECT IDENTIFIER
.1.3.6.1.4.1.6527.3.1.1.74.2.2
tmnxPtp1588Objs
OBJECT IDENTIFIER
.1.3.6.1.4.1.6527.3.1.2.74
tmnxPtp1588ConfigTimeStamps
OBJECT IDENTIFIER
.1.3.6.1.4.1.6527.3.1.2.74.1
tmnxPtpPeerConfigTblLastChangedro
TimeStamp (SNMPv2-TC)
.1.3.6.1.4.1.6527.3.1.2.74.1.1
tmnxPtpVRtrIfTableLastChangedro
TimeStamp (SNMPv2-TC)
.1.3.6.1.4.1.6527.3.1.2.74.1.2
tmnxPtp1588Configurations
OBJECT IDENTIFIER
.1.3.6.1.4.1.6527.3.1.2.74.2
tmnxPtpClockConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.6527.3.1.2.74.2.1
tmnxPtpClockAdminStaterw
TmnxAdminState (TIMETRA-TC-MIB)
.1.3.6.1.4.1.6527.3.1.2.74.2.1.1
tmnxPtpClockClockTyperw
TmnxPtpClockType
.1.3.6.1.4.1.6527.3.1.2.74.2.1.2
tmnxPtpClockProfilerw
TmnxPtpProfile
.1.3.6.1.4.1.6527.3.1.2.74.2.1.3
tmnxPtpClockDomainrw
TmnxPtpDomain
.1.3.6.1.4.1.6527.3.1.2.74.2.1.4
tmnxPtpClockAnnounceIntervalrw
TmnxPtpLogInterval (-3..4)
.1.3.6.1.4.1.6527.3.1.2.74.2.1.5
tmnxPtpClockPriority1rw
TmnxPtpPriority
.1.3.6.1.4.1.6527.3.1.2.74.2.1.6
tmnxPtpClockPriority2rw
TmnxPtpPriority
.1.3.6.1.4.1.6527.3.1.2.74.2.1.7
tmnxPtpClockWaitToRestorerw
Unsigned32 (0|1..600) UNITS "seconds"
.1.3.6.1.4.1.6527.3.1.2.74.2.1.8
tmnxPtpClockNetworkTyperw
Enumeration
.1.3.6.1.4.1.6527.3.1.2.74.2.1.9
tmnxPtpPeerConfigTable
SEQUENCE OF TmnxPtpPeerConfigEntry
.1.3.6.1.4.1.6527.3.1.2.74.2.3
tmnxPtpPeerConfigEntry
TmnxPtpPeerConfigEntry
.1.3.6.1.4.1.6527.3.1.2.74.2.3.1
tmnxPtpPeerIpAddrType
InetAddressType (INET-ADDRESS-MIB)
.1.3.6.1.4.1.6527.3.1.2.74.2.3.1.1
tmnxPtpPeerIpAddress
InetAddress
.1.3.6.1.4.1.6527.3.1.2.74.2.3.1.2
tmnxPtpPeerRowStatusrw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.6527.3.1.2.74.2.3.1.3
tmnxPtpPeerLastChangedro
TimeStamp (SNMPv2-TC)
.1.3.6.1.4.1.6527.3.1.2.74.2.3.1.4
tmnxPtpPeerAdminStaterw
TmnxAdminState (TIMETRA-TC-MIB)
.1.3.6.1.4.1.6527.3.1.2.74.2.3.1.5
tmnxPtpPeerPortStatero
TmnxPtpPortState
.1.3.6.1.4.1.6527.3.1.2.74.2.3.1.6
tmnxPtpPeerLocalPriorityrw
TmnxPtpPriority
.1.3.6.1.4.1.6527.3.1.2.74.2.3.1.7
tmnxPtpPeerRemoteMasterrw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.6527.3.1.2.74.2.3.1.8
tmnxPtpPeerRemoteSlavero
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.6527.3.1.2.74.2.3.1.9
tmnxPtpPeerClockIdro
TmnxPtpClockIdentity
.1.3.6.1.4.1.6527.3.1.2.74.2.3.1.10
tmnxPtpPeerLocalPortNumberro
TmnxPtpPortNumber
.1.3.6.1.4.1.6527.3.1.2.74.2.3.1.11
tmnxPtpPeerRemotePortNumberro
TmnxPtpPortNumber
.1.3.6.1.4.1.6527.3.1.2.74.2.3.1.12
tmnxPtpPeerTxTimeStampPointro
TmnxPtpTimeStampReferencePoint
.1.3.6.1.4.1.6527.3.1.2.74.2.3.1.13
tmnxPtpPeerLastTxPortIdro
TmnxPortID (TIMETRA-TC-MIB)
.1.3.6.1.4.1.6527.3.1.2.74.2.3.1.14
tmnxPtpPeerLastTxPortEncapTypero
TmnxPortEncapType
.1.3.6.1.4.1.6527.3.1.2.74.2.3.1.15
tmnxPtpPeerLastTxPortEncapValuero
TmnxEncapVal (TIMETRA-TC-MIB)
.1.3.6.1.4.1.6527.3.1.2.74.2.3.1.16
tmnxPtpPeerRxTimeStampPointro
TmnxPtpTimeStampReferencePoint
.1.3.6.1.4.1.6527.3.1.2.74.2.3.1.17
tmnxPtpPeerLastRxPortIdro
TmnxPortID (TIMETRA-TC-MIB)
.1.3.6.1.4.1.6527.3.1.2.74.2.3.1.18
tmnxPtpPeerLastRxPortEncapTypero
TmnxPortEncapType
.1.3.6.1.4.1.6527.3.1.2.74.2.3.1.19
tmnxPtpPeerLastRxPortEncapValuero
TmnxEncapVal (TIMETRA-TC-MIB)
.1.3.6.1.4.1.6527.3.1.2.74.2.3.1.20
tmnxPtpVRtrIfTable
SEQUENCE OF TmnxPtpVRtrIfEntry
.1.3.6.1.4.1.6527.3.1.2.74.2.4
tmnxPtpVRtrIfEntry
TmnxPtpVRtrIfEntry
.1.3.6.1.4.1.6527.3.1.2.74.2.4.1
tmnxPtpVRtrIfAdminStaterw
TmnxAdminState (TIMETRA-TC-MIB)
.1.3.6.1.4.1.6527.3.1.2.74.2.4.1.1
tmnxPtp1588Status
OBJECT IDENTIFIER
.1.3.6.1.4.1.6527.3.1.2.74.3
tmnxPtpClockOperTable
SEQUENCE OF TmnxPtpClockOperEntry
.1.3.6.1.4.1.6527.3.1.2.74.3.1
tmnxPtpClockOperEntry
TmnxPtpClockOperEntry
.1.3.6.1.4.1.6527.3.1.2.74.3.1.1
tmnxPtpClockIdentityro
TmnxPtpClockIdentity
.1.3.6.1.4.1.6527.3.1.2.74.3.1.1.1
tmnxPtpClockOperStatero
TmnxOperState (TIMETRA-TC-MIB)
.1.3.6.1.4.1.6527.3.1.2.74.3.1.1.2
tmnxPtpClockStepTypero
TmnxPtpClockStepType
.1.3.6.1.4.1.6527.3.1.2.74.3.1.1.3
tmnxPtpClockClassro
TmnxPtpClockClass
.1.3.6.1.4.1.6527.3.1.2.74.3.1.1.4
tmnxPtpClockAccuracyro
TmnxPtpClockAccuracy
.1.3.6.1.4.1.6527.3.1.2.74.3.1.1.5
tmnxPtpClockVariancero
TmnxPtpClockVariance
.1.3.6.1.4.1.6527.3.1.2.74.3.1.1.6
tmnxPtpClockPortStatero
TmnxPtpPortState
.1.3.6.1.4.1.6527.3.1.2.74.3.1.1.7
tmnxPtpClockPortStateLastChangedro
TimeStamp (SNMPv2-TC)
.1.3.6.1.4.1.6527.3.1.2.74.3.1.1.8
tmnxPtpClockRecoveryStatero
Enumeration
.1.3.6.1.4.1.6527.3.1.2.74.3.1.1.9
tmnxPtpClockRecoveryStateLastChgro
TimeStamp (SNMPv2-TC)
.1.3.6.1.4.1.6527.3.1.2.74.3.1.1.10
tmnxPtpClockFrequencyOffsetro
Integer32 UNITS "parts per trillion"
.1.3.6.1.4.1.6527.3.1.2.74.3.1.1.11
tmnxPtpMasterClockOper
OBJECT IDENTIFIER
.1.3.6.1.4.1.6527.3.1.2.74.3.2
tmnxPtpMasterClockAddressTypero
InetAddressType (INET-ADDRESS-MIB)
.1.3.6.1.4.1.6527.3.1.2.74.3.2.1
tmnxPtpMasterClockAddressro
InetAddress
.1.3.6.1.4.1.6527.3.1.2.74.3.2.2
tmnxPtpMasterClockGMClockIdro
TmnxPtpClockIdentity
.1.3.6.1.4.1.6527.3.1.2.74.3.2.3
tmnxPtpMasterClockGMClockPrio1ro
TmnxPtpPriority
.1.3.6.1.4.1.6527.3.1.2.74.3.2.4
tmnxPtpMasterClockGMClockPrio2ro
TmnxPtpPriority
.1.3.6.1.4.1.6527.3.1.2.74.3.2.5
tmnxPtpMasterClockGMClockClassro
TmnxPtpClockClass
.1.3.6.1.4.1.6527.3.1.2.74.3.2.6
tmnxPtpMasterClockGMAccuracyro
TmnxPtpClockAccuracy
.1.3.6.1.4.1.6527.3.1.2.74.3.2.7
tmnxPtpMasterClockGMVariancero
TmnxPtpClockVariance
.1.3.6.1.4.1.6527.3.1.2.74.3.2.8
tmnxPtpMasterClockParentClockIdro
TmnxPtpClockIdentity
.1.3.6.1.4.1.6527.3.1.2.74.3.2.9
tmnxPtpMasterClockParentPortNumro
TmnxPtpPortNumber
.1.3.6.1.4.1.6527.3.1.2.74.3.2.10
tmnxPtpPeerMasterStatusTable
SEQUENCE OF TmnxPtpPeerMasterStatusEntry
.1.3.6.1.4.1.6527.3.1.2.74.3.3
tmnxPtpPeerMasterStatusEntry
TmnxPtpPeerMasterStatusEntry
.1.3.6.1.4.1.6527.3.1.2.74.3.3.1
tmnxPtpPeerMasterCurrentMasterro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.6527.3.1.2.74.3.3.1.1
tmnxPtpPeerMasterClockStepTypero
TmnxPtpClockStepType
.1.3.6.1.4.1.6527.3.1.2.74.3.3.1.2
tmnxPtpPeerMasterClockStepsRemvdro
Unsigned32
.1.3.6.1.4.1.6527.3.1.2.74.3.3.1.3
tmnxPtpPeerMasterGMClockIdro
TmnxPtpClockIdentity
.1.3.6.1.4.1.6527.3.1.2.74.3.3.1.4
tmnxPtpPeerMasterGMClockPrio1ro
TmnxPtpPriority
.1.3.6.1.4.1.6527.3.1.2.74.3.3.1.5
tmnxPtpPeerMasterGMClockPrio2ro
TmnxPtpPriority
.1.3.6.1.4.1.6527.3.1.2.74.3.3.1.6
tmnxPtpPeerMasterGMClockClassro
TmnxPtpClockClass
.1.3.6.1.4.1.6527.3.1.2.74.3.3.1.7
tmnxPtpPeerMasterGMClockAccuracyro
TmnxPtpClockAccuracy
.1.3.6.1.4.1.6527.3.1.2.74.3.3.1.8
tmnxPtpPeerMasterGMClockVariancero
TmnxPtpClockVariance
.1.3.6.1.4.1.6527.3.1.2.74.3.3.1.9
tmnxPtpPeerMasterWaitUntilRestrro
Unsigned32 UNITS "seconds"
.1.3.6.1.4.1.6527.3.1.2.74.3.3.1.10
tmnxPtpPeerMasterAlarmro
Bits
.1.3.6.1.4.1.6527.3.1.2.74.3.3.1.11
tmnxPtpPeerUnicastTable
SEQUENCE OF TmnxPtpPeerUnicastEntry
.1.3.6.1.4.1.6527.3.1.2.74.3.4
tmnxPtpPeerUnicastEntry
TmnxPtpPeerUnicastEntry
.1.3.6.1.4.1.6527.3.1.2.74.3.4.1
tmnxPtpPeerUnicastDirection
TmnxPtpDirection
.1.3.6.1.4.1.6527.3.1.2.74.3.4.1.1
tmnxPtpPeerUnicastPktType
Enumeration
.1.3.6.1.4.1.6527.3.1.2.74.3.4.1.2
tmnxPtpPeerUnicastStatusro
Enumeration
.1.3.6.1.4.1.6527.3.1.2.74.3.4.1.3
tmnxPtpPeerUnicastRatero
TmnxPtpLogInterval
.1.3.6.1.4.1.6527.3.1.2.74.3.4.1.4
tmnxPtpPeerUnicastDurationro
Unsigned32 UNITS "seconds"
.1.3.6.1.4.1.6527.3.1.2.74.3.4.1.5
tmnxPtpPeerUnicastEventTimero
TimeStamp (SNMPv2-TC)
.1.3.6.1.4.1.6527.3.1.2.74.3.4.1.6
tmnxPtpTimeInformation
OBJECT IDENTIFIER
.1.3.6.1.4.1.6527.3.1.2.74.3.5
tmnxPtpTimeInfoTimescalero
Enumeration
.1.3.6.1.4.1.6527.3.1.2.74.3.5.1
tmnxPtpTimeInfoCurrentTimero
DateAndTime
.1.3.6.1.4.1.6527.3.1.2.74.3.5.2
tmnxPtpTimeInfoFreqTraceablero
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.6527.3.1.2.74.3.5.3
tmnxPtpTimeInfoTimeTraceablero
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.6527.3.1.2.74.3.5.4
tmnxPtpTimeInfoTimeSourcero
Enumeration
.1.3.6.1.4.1.6527.3.1.2.74.3.5.5
tmnxPtp1588Statistics
OBJECT IDENTIFIER
.1.3.6.1.4.1.6527.3.1.2.74.5
tmnxPtpClockPacketStatsTable
SEQUENCE OF TmnxPtpClockPacketStatsEntry
.1.3.6.1.4.1.6527.3.1.2.74.5.1
Showing 100 of 189 OID objects

TIMETRA-PTP-MIB Technical Reference Overview

The TIMETRA-PTP-MIB SNMP MIB module published by Alcatel-Lucent defines 189 managed OID objects, including 152 scalar/column metrics, 7 SNMP tables, and 7 trap/notification events anchored at base OID .1.3.6.1.4.1.6527.1.1.3.74. Key tabular structures include tmnxPtpClockOperTable, tmnxPtpPeerConfigTable, tmnxPtpPeerMasterStatusTable, tmnxPtpPeerUnicastTable, tmnxPtpClockPacketStatsTable, tmnxPtpPeerPacketStatsTable. Monitored SNMP traps/notifications include tmnxPtpCardNotSupported, tmnxPtpCardNotSupportedClear, tmnxPtpMasterClockChangedEvent, tmnxPtpClockRecoveryStateChange, tmnxPtpOutOfResources, tmnxPtpOutOfResourcesClear.

Key OID Definitions in TIMETRA-PTP-MIB

timetraPtpMIBModuleMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.6527.1.1.3.74

This document is the SNMP MIB module to manage and provision the Precision Time Protocol (PTP) components of the Alcatel-Lucent SROS device as defined in the IEEE Standard for a Precision Clock Synchronization Protocol for Networked Measurement and Control Systems (IEEE Std 1588-2008). Copyright (c) 2011-2014 Alcatel-Lucent. All rights reserved. Reproduction of this document is authorized on the condition that the foregoing copyright notice is included. This SNMP MIB module (Specification) embodies Alcatel-Lucent's proprietary intellectual property. Alcatel-Lucent retains all title and ownership in the Specification, including any revisions. Alcatel-Lucent grants all interested parties a non-exclusive license to use and distribute an unmodified copy of this Specification in connection with management of Alcatel-Lucent products, and without fee, provided this copyright notice and license appear on all copies. This Specification is supplied 'as is', and Alcatel-Lucent makes no warranty, either express or implied, as to the use, operation, condition, or performance of the Specification.

tmnxPtpClockOperTableSEQUENCEnot-accessible
.1.3.6.1.4.1.6527.3.1.2.74.3.1

The tmnxPtpClockOperTable contains the operational information for the individual Precision Timing Protocol (PTP) for each CPM card in the SROS system.

tmnxPtpPeerConfigTableSEQUENCEnot-accessible
.1.3.6.1.4.1.6527.3.1.2.74.2.3

The tmnxPtpPeerConfigTable consists of peer configuration information.

tmnxPtpPeerMasterStatusTableSEQUENCEnot-accessible
.1.3.6.1.4.1.6527.3.1.2.74.3.3

The tmnxPtpPeerMasterStatusTable consists of Precision Time Protocol Master Peer state information. This table extends the tmnxPtpPeerConfigTable for peers configured as grandmaster or boundary PTP clocks that may provide timing information to the local clock.

tmnxPtpPeerUnicastTableSEQUENCEnot-accessible
.1.3.6.1.4.1.6527.3.1.2.74.3.4

The tmnxPtpPeerUnicastTable consists of the status of unicast messaging service between the local PTP clock and all other PTP clocks.

tmnxPtpClockPacketStatsTableSEQUENCEnot-accessible
.1.3.6.1.4.1.6527.3.1.2.74.5.1

The tmnxPtpClockPacketStatsTable consists of the packet statistics associated with the Precision Time Protocol (PTP).

tmnxPtpPeerPacketStatsTableSEQUENCEnot-accessible
.1.3.6.1.4.1.6527.3.1.2.74.5.2

The tmnxPtpPeerPacketStatsTable consists of the per peer packet statistics associated with the Precision Time Protocol (PTP).

tmnxPtpVRtrIfTableSEQUENCEnot-accessible
.1.3.6.1.4.1.6527.3.1.2.74.2.4

The tmnxPtpVRtrIfTable table contains PTP configuration pertaining to IP interfaces.

tmnxPtpCardNotSupportedNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6527.3.1.3.74.0.1

The tmnxPtpCardNotSupported notification is generated when the Precision Timing Protocol (PTP) is enabled on a card that is not capable of clock recovery using PTP. This notification is triggered when the TIMETRA-CHASSIS-MIB::tmnxCpmCardOscillatorType is not 'ocxo (3)', the tmnxPtpClockClockType is set to 'ordinarySlave (1)' or 'boundary (3)', and tmnxPtpClockAdminState is set to 'inService (2)'. [EFFECT] While this event is active, tmnxPtpClockOperState will be 'outOfService (3)' on the card that this notification was generated. [RECOVERY] This event is cleared when a replacement CPM card with an Oscillator of type 'ocxo (3)' is inserted. tmnxPtpCardNotSupportedClear is generated when this event is cleared.

tmnxPtpCardNotSupportedClearNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6527.3.1.3.74.0.2

The tmnxPtpCardNotSupportedClear notification is generated when the tmnxPtpCardNotSupported event is cleared for a particular CPM card.

tmnxPtpMasterClockChangedEventNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6527.3.1.3.74.0.3

The tmnxPtpMasterClockChangedEvent is generated when the Master/Parent Clock for the Precision Timing Protocol (PTP) changes on the system.

tmnxPtpClockRecoveryStateChangeNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6527.3.1.3.74.0.4

The tmnxPtpClockRecoveryStateChange is generated when the Precision Timing Protocol (PTP) clock recovery state changes on the system.

tmnxPtpOutOfResourcesNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6527.3.1.3.74.0.5

The tmnxPtpOutOfResources notification is generated when the Precision Timing Protocol (PTP) process on the card is out of resources. This may occur in either two situations: 1. The number of PTP peers exceeds the system limit. 2. The total unicast packet rate negotiated with all PTP peers has reached the maximum packet rate supported by the system. Exceeding this rate would impact the ability of the master clock to provide an accurate stream of timing packets to each remote slave clock. If either of the above two situation occurs, the PTP process will reject any new unicast packet requests from remote slave PTP peers. tmnxPtpOutOfResourcesClear is generated when this event is cleared.

tmnxPtpOutOfResourcesClearNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6527.3.1.3.74.0.6

The tmnxPtpOutOfResourcesClear notification is generated when both the total number of active PTP peers and the total negotiated unicast packet rate goes below 90% of the system limit.

tmnxPtpDynamicChangeNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6527.3.1.3.74.0.7

The tmnxPtpDynamicChange notification is generated when an object dynamically (i.e. not by configuration) changes state. This notification identifies the affected row.

tmnxPtpClockAdminStateTmnxAdminStateread-write
.1.3.6.1.4.1.6527.3.1.2.74.2.1.1

The value of tmnxPtpClockAdminState specifies whether PTP 1588 is enabled on the system or not.

tmnxPtpClockClockTypeTmnxPtpClockTyperead-write
.1.3.6.1.4.1.6527.3.1.2.74.2.1.2

The value of tmnxPtpClockClockType specifies the clock behavior of PTP1588 on the system. This object can only be modified if tmnxPtpClockAdminState is set to 'outOfService (3)', otherwise an 'inconsistentValue' error is returned.

tmnxPtpClockProfileTmnxPtpProfileread-write
.1.3.6.1.4.1.6527.3.1.2.74.2.1.3

The value of tmnxPtpClockProfile specifies the conformance of the PTP system to either the default IEEE 1588-2008 behavior, or the ITU-T profile. Modification of this object indirectly resets the value of tmnxPtpClockDomain to the corresponding default value for the specified profile. This object can only be modified if tmnxPtpClockAdminState is set to 'outOfService (3)', otherwise an 'inconsistentValue' error is returned.

tmnxPtpClockDomainTmnxPtpDomainread-write
.1.3.6.1.4.1.6527.3.1.2.74.2.1.4

The value of tmnxPtpClockDomain specifies the domain in which PTP 1588 runs on the system. This object can only be modified if tmnxPtpClockAdminState is set to 'outOfService (3)', otherwise an 'inconsistentValue' error is returned.

tmnxPtpClockAnnounceIntervalTmnxPtpLogIntervalread-write
.1.3.6.1.4.1.6527.3.1.2.74.2.1.5

The value of tmnxPtpClockAnnounceInterval specifies the packet rate requested in REQUEST_UNICAST_TRANSMISSION signaling messages for announce packets. This object can only be modified if tmnxPtpClockAdminState is set to 'outOfService (3)', otherwise an 'inconsistentValue' error is returned.

tmnxPtpClockPriority1TmnxPtpPriorityread-write
.1.3.6.1.4.1.6527.3.1.2.74.2.1.6

The value of tmnxPtpClockPriority1 specifies the value of the defaultDS.priority1 data set member defined in IEEE Std 1588-2008.

tmnxPtpClockPriority2TmnxPtpPriorityread-write
.1.3.6.1.4.1.6527.3.1.2.74.2.1.7

The value of tmnxPtpClockPriority2 specifies the value of the defaultDS.priority2 data set member defined in IEEE Std 1588-2008.

tmnxPtpClockWaitToRestoreUnsigned32read-write
.1.3.6.1.4.1.6527.3.1.2.74.2.1.8

The value of tmnxPtpClockWaitToRestore specifies the time to wait after an Announce Receipt Timeout expires before considering further announce messages from a peer for the purposes of selecting a master clock. The value zero (0), specifies no wait time. This object can only be modified if tmnxPtpClockAdminState is set to 'outOfService (3)', otherwise an 'inconsistentValue' error is returned.

tmnxPtpClockNetworkTypeINTEGERread-write
.1.3.6.1.4.1.6527.3.1.2.74.2.1.9

The value of tmnxPtpClockNetworkType specifies whether the SROS is configured to use PTP clock classes corresponding to SONET or SDH quality levels.

More MIBs from Alcatel-Lucent

Browse all Alcatel-LucentMIBs →
TIMETRA-SERV-MIB

The TIMETRA-SERV-MIB provides SNMP access to provision and monitor service-specific operational states, including pseudowire configurations, VPLS instances, and MPLS-TE tunnels on Alcatel-Lucent (now Nokia) SR OS routers. It enables granular management of Layer 2 and Layer 3 service parameters, such as circuit identifiers, binding status, and traffic statistics, essential for maintaining carrier-grade service delivery.

1472 objects→
TIMETRA-SUBSCRIBER-MGMT-MIB

The TIMETRA-SUBSCRIBER-MGMT-MIB enables SNMP-based monitoring and configuration of subscriber session states, service profiles, and authentication parameters on Alcatel-Lucent (now Nokia) SR OS (Service Router Operating System) platforms. It provides granular visibility into active subscriber counts, session lifecycles, and policy enforcement metrics essential for managing broadband and mobile subscriber traffic on the SROS series.

1428 objects→
TIMETRA-VRTR-MIB

The TIMETRA-VRTR-MIB facilitates the SNMP-based provisioning and monitoring of virtual routers, transport interfaces, and associated routing features on Alcatel-Lucent (now Nokia) SR OS (Service Router Operating System) platforms. This module provides access to specific configuration parameters and operational state metrics required to manage the logical separation of routing instances and their underlying transport resources.

1346 objects→
TIMETRA-MOBILE-PDN-MIB

The TIMETRA-MOBILE-PDN-MIB enables SNMP-based provisioning and monitoring of Alcatel-Lucent Packet Data Network Gateway (PGW) instances, specifically managing LTE/4G mobile core session states, bearer configurations, and PDN connectivity parameters.

1202 objects→
TIMETRA-BSX-NG-MIB

The TIMETRA-BSX-NG-MIB enables SNMP-based provisioning and monitoring of Application Assurance features on Alcatel-Lucent SR OS (SROS) routers, specifically managing traffic classification, policy enforcement, and session state metrics for deep packet inspection services.

1132 objects→
TIMETRA-QOS-MIB

The TIMETRA-QOS-MIB enables SNMP-based configuration and monitoring of Quality of Service parameters, including traffic policing, shaping, queuing, and scheduling, on Alcatel-Lucent (now Nokia) SR OS (Service Router Operating System) platforms. It provides granular visibility into bandwidth allocation, drop rates, and queue depths to enforce service level agreements and manage network congestion.

1113 objects→