TERACOM-MIB
AI MIB Summary
The TERACOM-MIB facilitates SNMP-based monitoring and management of TCW240 network entities, enabling the retrieval of operational status, interface statistics, and device performance metrics specific to Teracom hardware.
The MIB module for TCW240 SNMP entities.
Main OID:
snmpMIB.1.3.6.1.6.3.1
212
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
212 total| Object Name |
|---|
teracom OBJECT IDENTIFIER .1.3.6.1.4.1.38783 |
tcw240b OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1 |
trapNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.0 |
snmp_trap_notificationSMIV2 Trap notification information for the SNMP Manager. NOTIFICATION-TYPE .1.3.6.1.4.1.38783.1.0.1 |
product OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.1 |
nameName of product. e.g. teracom.cc etc.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.38783.1.1.1 |
versionVersion string. e.g. 1.0ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.38783.1.1.2 |
dateTimeDate and timero DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.38783.1.1.3 |
setup OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.2 |
network OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.2.1 |
deviceIDDevice ID is Default MAC Addressro MacAddress (SNMPv2-TC) .1.3.6.1.4.1.38783.1.2.1.1 |
hostNameHost Namero DisplayString .1.3.6.1.4.1.38783.1.2.1.2 |
deviceIPDevice IP Addressro IpAddress .1.3.6.1.4.1.38783.1.2.1.3 |
io OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.2.2 |
sensorsSetup OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.2.2.1 |
sensor1setup OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.2.2.1.1 |
s1descriptionSensor1 descriptionrw DisplayString .1.3.6.1.4.1.38783.1.2.2.1.1.1 |
sensor11setup OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.2.2.1.1.2 |
s11MAXx10IntS11 maximum value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.1.2.1 |
s11MINx10IntS11 minimum value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.1.2.2 |
s11HYSTx10IntS11 hysteresis value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.1.2.3 |
sensor12setup OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.2.2.1.1.3 |
s12MAXx10IntS12 maximum value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.1.3.1 |
s12MINx10IntS12 minimum value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.1.3.2 |
s12HYSTx10IntS12 hysteresis value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.1.3.3 |
sensor2setup OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.2.2.1.2 |
s2descriptionsensor2 descriptionrw DisplayString .1.3.6.1.4.1.38783.1.2.2.1.2.1 |
sensor21setup OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.2.2.1.2.2 |
s21MAXx10Ints21 maximum value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.2.2.1 |
s21MINx10Ints21 minimum value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.2.2.2 |
s21HYSTx10Ints21 hysteresis value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.2.2.3 |
sensor22setup OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.2.2.1.2.3 |
s22MAXx10Ints22 maximum value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.2.3.1 |
s22MINx10Ints22 minimum value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.2.3.2 |
s22HYSTx10Ints22 hysteresis value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.2.3.3 |
sensor3setup OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.2.2.1.3 |
s3descriptionsensor3 descriptionrw DisplayString .1.3.6.1.4.1.38783.1.2.2.1.3.1 |
sensor31setup OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.2.2.1.3.2 |
s31MAXx10Ints31 maximum value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.3.2.1 |
s31MINx10Ints31 minimum value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.3.2.2 |
s31HYSTx10Ints31 hysteresis value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.3.2.3 |
sensor32setup OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.2.2.1.3.3 |
s32MAXx10Ints32 maximum value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.3.3.1 |
s32MINx10Ints32 minimum value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.3.3.2 |
s32HYSTx10Ints32 hysteresis value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.3.3.3 |
sensor4setup OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.2.2.1.4 |
s4descriptionsensor4 descriptionrw DisplayString .1.3.6.1.4.1.38783.1.2.2.1.4.1 |
sensor41setup OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.2.2.1.4.2 |
s41MAXx10Ints41 maximum value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.4.2.1 |
s41MINx10Ints41 minimum value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.4.2.2 |
s41HYSTx10Ints41 hysteresis value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.4.2.3 |
sensor42setup OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.2.2.1.4.3 |
s42MAXx10Ints42 maximum value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.4.3.1 |
s42MINx10Ints42 minimum value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.4.3.2 |
s42HYSTx10Ints42 hysteresis value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.4.3.3 |
sensor5setup OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.2.2.1.5 |
s5descriptionsensor5 descriptionrw DisplayString .1.3.6.1.4.1.38783.1.2.2.1.5.1 |
sensor51setup OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.2.2.1.5.2 |
s51MAXx10Ints51 maximum value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.5.2.1 |
s51MINx10Ints51 minimum value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.5.2.2 |
s51HYSTx10Ints51 hysteresis value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.5.2.3 |
sensor52setup OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.2.2.1.5.3 |
s52MAXx10Ints52 maximum value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.5.3.1 |
s52MINx10Ints52 minimum value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.5.3.2 |
s52HYSTx10Ints52 hysteresis value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.5.3.3 |
sensor6setup OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.2.2.1.6 |
s6descriptionsensor6 descriptionrw DisplayString .1.3.6.1.4.1.38783.1.2.2.1.6.1 |
sensor61setup OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.2.2.1.6.2 |
s61MAXx10Ints61 maximum value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.6.2.1 |
s61MINx10Ints61 minimum value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.6.2.2 |
s61HYSTx10Ints61 hysteresis value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.6.2.3 |
sensor62setup OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.2.2.1.6.3 |
s62MAXx10Ints62 maximum value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.6.3.1 |
s62MINx10Ints62 minimum value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.6.3.2 |
s62HYSTx10Ints62 hysteresis value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.6.3.3 |
sensor7setup OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.2.2.1.7 |
s7descriptionsensor7 descriptionrw DisplayString .1.3.6.1.4.1.38783.1.2.2.1.7.1 |
sensor71setup OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.2.2.1.7.2 |
s71MAXx10Ints71 maximum value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.7.2.1 |
s71MINx10Ints71 minimum value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.7.2.2 |
s71HYSTx10Ints71 hysteresis value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.7.2.3 |
sensor72setup OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.2.2.1.7.3 |
s72MAXx10Ints72 maximum value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.7.3.1 |
s72MINx10Ints72 minimum value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.7.3.2 |
s72HYSTx10Ints72 hysteresis value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.7.3.3 |
sensor8setup OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.2.2.1.8 |
s8descriptionsensor8 descriptionrw DisplayString .1.3.6.1.4.1.38783.1.2.2.1.8.1 |
sensor81setup OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.2.2.1.8.2 |
s81MAXx10Ints81 maximum value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.8.2.1 |
s81MINx10Ints81 minimum value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.8.2.2 |
s81HYSTx10Ints81 hysteresis value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.8.2.3 |
sensor82setup OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.2.2.1.8.3 |
s82MAXx10Ints82 maximum value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.8.3.1 |
s82MINx10Ints82 minimum value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.8.3.2 |
s82HYSTx10Ints82 hysteresis value x10 in Integer formatrw Integer32 .1.3.6.1.4.1.38783.1.2.2.1.8.3.3 |
analogSetup OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.2.2.2 |
analog1setup OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.2.2.2.1 |
voltage1descriptionVoltage 1 descriptionrw DisplayString .1.3.6.1.4.1.38783.1.2.2.2.1.1 |
voltage1maxVoltage 1 maximumrw Integer32 .1.3.6.1.4.1.38783.1.2.2.2.1.2 |
voltage1minVoltage 1 minimumrw Integer32 .1.3.6.1.4.1.38783.1.2.2.2.1.3 |
voltage1hystVoltage 1 hysteresisrw Integer32 .1.3.6.1.4.1.38783.1.2.2.2.1.4 |
analog2setup OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.2.2.2.2 |
voltage2descriptionVoltage 2 descriptionrw DisplayString .1.3.6.1.4.1.38783.1.2.2.2.2.1 |
voltage2maxVoltage 2 maximumrw Integer32 .1.3.6.1.4.1.38783.1.2.2.2.2.2 |
voltage2minVoltage 2 minimumrw Integer32 .1.3.6.1.4.1.38783.1.2.2.2.2.3 |
voltage2hystVoltage 2 hysteresisrw Integer32 .1.3.6.1.4.1.38783.1.2.2.2.2.4 |
analog3setup OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.2.2.2.3 |
voltage3descriptionVoltage 3 descriptionrw DisplayString .1.3.6.1.4.1.38783.1.2.2.2.3.1 |
voltage3maxVoltage 3 maximumrw Integer32 .1.3.6.1.4.1.38783.1.2.2.2.3.2 |
voltage3minVoltage 3 minimumrw Integer32 .1.3.6.1.4.1.38783.1.2.2.2.3.3 |
voltage3hystVoltage 3 hysteresisrw Integer32 .1.3.6.1.4.1.38783.1.2.2.2.3.4 |
analog4setup OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.2.2.2.4 |
voltage4descriptionVoltage 4 descriptionrw DisplayString .1.3.6.1.4.1.38783.1.2.2.2.4.1 |
voltage4maxVoltage 4 maximumrw Integer32 .1.3.6.1.4.1.38783.1.2.2.2.4.2 |
voltage4minVoltage 4 minimumrw Integer32 .1.3.6.1.4.1.38783.1.2.2.2.4.3 |
voltage4hystVoltage 4 hysteresisrw Integer32 .1.3.6.1.4.1.38783.1.2.2.2.4.4 |
digitalSetup OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.2.2.3 |
digitalInput1descriptionDigital Input 1 descriptionrw DisplayString .1.3.6.1.4.1.38783.1.2.2.3.1 |
digitalInput2descriptionDigital Input 2 descriptionrw DisplayString .1.3.6.1.4.1.38783.1.2.2.3.2 |
digitalInput3descriptionDigital Input 3 descriptionrw DisplayString .1.3.6.1.4.1.38783.1.2.2.3.3 |
digitalInput4descriptionDigital Input 4 descriptionrw DisplayString .1.3.6.1.4.1.38783.1.2.2.3.4 |
relaysSetup OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.2.2.4 |
relay1setup OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.2.2.4.1 |
relay1descriptionRelay 1 descriptionrw DisplayString .1.3.6.1.4.1.38783.1.2.2.4.1.1 |
relay1pulseWidthRelay1 Pulse x100msrw Integer32 .1.3.6.1.4.1.38783.1.2.2.4.1.2 |
relay1controlledByRelay1 control logicrw CONTROLLED .1.3.6.1.4.1.38783.1.2.2.4.1.3 |
relay2setup OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.2.2.4.2 |
relay2descriptionRelay 2 descriptionrw DisplayString .1.3.6.1.4.1.38783.1.2.2.4.2.1 |
relay2pulseWidthRelay2 Pulse x100msrw Integer32 .1.3.6.1.4.1.38783.1.2.2.4.2.2 |
relay2controlledByRelay2 control logicrw CONTROLLED .1.3.6.1.4.1.38783.1.2.2.4.2.3 |
relay3setup OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.2.2.4.3 |
relay3descriptionRelay 3 descriptionrw DisplayString .1.3.6.1.4.1.38783.1.2.2.4.3.1 |
relay3pulseWidthRelay3 Pulse x100msrw Integer32 .1.3.6.1.4.1.38783.1.2.2.4.3.2 |
relay3controlledByRelay3 control logicrw CONTROLLED .1.3.6.1.4.1.38783.1.2.2.4.3.3 |
relay4setup OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.2.2.4.4 |
relay4descriptionRelay 4 descriptionrw DisplayString .1.3.6.1.4.1.38783.1.2.2.4.4.1 |
relay4pulseWidthRelay4 Pulse x100msrw Integer32 .1.3.6.1.4.1.38783.1.2.2.4.4.2 |
relay4controlledByRelay4 control logicrw CONTROLLED .1.3.6.1.4.1.38783.1.2.2.4.4.3 |
monitorNcontrol OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.3 |
sensors OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.3.1 |
sensor1 OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.3.1.1 |
s11x10IntS11 value x10 in Integer formatro Integer32 .1.3.6.1.4.1.38783.1.3.1.1.1 |
s12x10IntS12 value x10 in Integer formatro Integer32 .1.3.6.1.4.1.38783.1.3.1.1.2 |
s1IDS1 ID valuero MacAddress (SNMPv2-TC) .1.3.6.1.4.1.38783.1.3.1.1.3 |
sensor2 OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.3.1.2 |
s21x10IntS21 value x10 in Integer formatro Integer32 .1.3.6.1.4.1.38783.1.3.1.2.1 |
s22x10IntS22 value x10 in Integer formatro Integer32 .1.3.6.1.4.1.38783.1.3.1.2.2 |
s2IDS2 ID valuero MacAddress (SNMPv2-TC) .1.3.6.1.4.1.38783.1.3.1.2.3 |
sensor3 OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.3.1.3 |
s31x10IntS31 value x10 in Integer formatro Integer32 .1.3.6.1.4.1.38783.1.3.1.3.1 |
s32x10IntS32 value x10 in Integer formatro Integer32 .1.3.6.1.4.1.38783.1.3.1.3.2 |
s3IDS3 ID valuero MacAddress (SNMPv2-TC) .1.3.6.1.4.1.38783.1.3.1.3.3 |
sensor4 OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.3.1.4 |
s41x10IntS41 value x10 in Integer formatro Integer32 .1.3.6.1.4.1.38783.1.3.1.4.1 |
s42x10IntS42 value x10 in Integer formatro Integer32 .1.3.6.1.4.1.38783.1.3.1.4.2 |
s4IDS4 ID valuero MacAddress (SNMPv2-TC) .1.3.6.1.4.1.38783.1.3.1.4.3 |
sensor5 OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.3.1.5 |
s51x10IntS51 value x10 in Integer formatro Integer32 .1.3.6.1.4.1.38783.1.3.1.5.1 |
s52x10IntS52 value x10 in Integer formatro Integer32 .1.3.6.1.4.1.38783.1.3.1.5.2 |
s5IDS5 ID valuero MacAddress (SNMPv2-TC) .1.3.6.1.4.1.38783.1.3.1.5.3 |
sensor6 OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.3.1.6 |
s61x10IntS61 value x10 in Integer formatro Integer32 .1.3.6.1.4.1.38783.1.3.1.6.1 |
s62x10IntS62 value x10 in Integer formatro Integer32 .1.3.6.1.4.1.38783.1.3.1.6.2 |
s6IDS6 ID valuero MacAddress (SNMPv2-TC) .1.3.6.1.4.1.38783.1.3.1.6.3 |
sensor7 OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.3.1.7 |
s71x10IntS71 value x10 in Integer formatro Integer32 .1.3.6.1.4.1.38783.1.3.1.7.1 |
s72x10IntS72 value x10 in Integer formatro Integer32 .1.3.6.1.4.1.38783.1.3.1.7.2 |
s7IDS7 ID valuero MacAddress (SNMPv2-TC) .1.3.6.1.4.1.38783.1.3.1.7.3 |
sensor8 OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.3.1.8 |
s81x10IntS81 value x10 in Integer formatro Integer32 .1.3.6.1.4.1.38783.1.3.1.8.1 |
s82x10IntS82 value x10 in Integer formatro Integer32 .1.3.6.1.4.1.38783.1.3.1.8.2 |
s8IDS8 ID valuero MacAddress (SNMPv2-TC) .1.3.6.1.4.1.38783.1.3.1.8.3 |
analog OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.3.2 |
voltage1x10IntVoltage1 x10 in Integer formatro Integer32 .1.3.6.1.4.1.38783.1.3.2.1 |
voltage2x10IntVoltage2 x10 in Integer formatro Integer32 .1.3.6.1.4.1.38783.1.3.2.2 |
voltage3x10IntVoltage3 x10 in Integer formatro Integer32 .1.3.6.1.4.1.38783.1.3.2.3 |
voltage4x10IntVoltage4 x10 in Integer formatro Integer32 .1.3.6.1.4.1.38783.1.3.2.4 |
voltage1x100IntVoltage1 x100 in Integer formatro Integer32 .1.3.6.1.4.1.38783.1.3.2.5 |
voltage2x100IntVoltage2 x100 in Integer formatro Integer32 .1.3.6.1.4.1.38783.1.3.2.6 |
voltage3x100IntVoltage3 x100 in Integer formatro Integer32 .1.3.6.1.4.1.38783.1.3.2.7 |
voltage4x100IntVoltage4 x100 in Integer formatro Integer32 .1.3.6.1.4.1.38783.1.3.2.8 |
digital OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.3.3 |
digitalInput1StateDigital1 Input Statero Enumeration .1.3.6.1.4.1.38783.1.3.3.1 |
digitalInput2StateDigital2 Input Statero Enumeration .1.3.6.1.4.1.38783.1.3.3.2 |
digitalInput3StateDigital3 Input Statero Enumeration .1.3.6.1.4.1.38783.1.3.3.3 |
digitalInput4StateDigital4 Input Statero Enumeration .1.3.6.1.4.1.38783.1.3.3.4 |
relays OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.3.4 |
relay1 OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.3.4.1 |
relay1StateRelay1 Staterw Enumeration .1.3.6.1.4.1.38783.1.3.4.1.1 |
relay1PulseRelay1 Pulserw Enumeration .1.3.6.1.4.1.38783.1.3.4.1.2 |
relay2 OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.3.4.2 |
relay2StateRelay2 Staterw Enumeration .1.3.6.1.4.1.38783.1.3.4.2.1 |
relay2PulseRelay2 Pulserw Enumeration .1.3.6.1.4.1.38783.1.3.4.2.2 |
relay3 OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.3.4.3 |
relay3StateRelay3 Staterw Enumeration .1.3.6.1.4.1.38783.1.3.4.3.1 |
relay3PulseRelay3 Pulserw Enumeration .1.3.6.1.4.1.38783.1.3.4.3.2 |
relay4 OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.3.4.4 |
relay4StateRelay4 Staterw Enumeration .1.3.6.1.4.1.38783.1.3.4.4.1 |
relay4PulseRelay4 Pulserw Enumeration .1.3.6.1.4.1.38783.1.3.4.4.2 |
configurationSavedConfiguration save status SAVED/UNSAVEDrw Enumeration .1.3.6.1.4.1.38783.1.3.5 |
restartDeviceRestart Devicerw Enumeration .1.3.6.1.4.1.38783.1.3.6 |
temperatureUnitUnit of the all temperature valuesro Enumeration .1.3.6.1.4.1.38783.1.3.7 |
hardwareErrHardware Errorro Enumeration .1.3.6.1.4.1.38783.1.3.8 |
tcw240bMIBConformance OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.4 |
tcw240bMIBCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.4.1 |
tcw240bMIBCompliances1This group is for SNMP applications. Unknown .1.3.6.1.4.1.38783.1.4.1.1 |
tcw240bMIBGroups OBJECT IDENTIFIER .1.3.6.1.4.1.38783.1.4.2 |
tcw240bProductGroupA collection of objects providing basic product info. Unknown .1.3.6.1.4.1.38783.1.4.2.1 |
tcw240bSetupGroupA collection of objects providing basic setup. Unknown .1.3.6.1.4.1.38783.1.4.2.2 |
tcw240bMonitorGroupA collection of objects providing basic monitoring and control of a product. Unknown .1.3.6.1.4.1.38783.1.4.2.3 |
tcw240bTrapGroupSNMP Trap Notification object. Unknown .1.3.6.1.4.1.38783.1.4.2.4 |
snmpMIBThe MIB module for TCW240 SNMP entities. MODULE-IDENTITY .1.3.6.1.6.3.1 |