Home/Catalog/SSG-5000-CHASSIS-MIB

SSG-5000-CHASSIS-MIB

AI MIB Summary

The SSG-5000-CHASSIS-MIB monitors the physical health and operational status of Juniper Networks SSG-5000 series security gateways, tracking critical chassis-level metrics such as power supply states, fan speeds, temperature sensors, and system module availability.

This MIB provides a means to monitor the status of a SSG system's health.
Main OID:
ssg5000ChassisMIB.1.3.6.1.4.1.3199.10.28
119
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

119 total
Object Name
ssg5000ChassisMIBThis MIB provides a means to monitor the status of a SSG system's health.
MODULE-IDENTITY
.1.3.6.1.4.1.3199.10.28
ssg5000ChassisMIBObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.3199.10.28.1
ssg5000ChassisGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.3199.10.28.1.1
ssg5000SysStatusThis is a bitmask value that indicates the system alarms: Bit Alarm 1 NODE_DEAD_ALARM 2 NODE_REBOOT_ALARM 3 FAN_DEAD_ALARM 4 FAN_FAILURE_ALARM 5 OVERTEMP_ALARM 6 DC_POWER_FAILURE_ALARM 7 AC_DC_SHELF_FAILURE_ALARM 8 AC_DC_SHELF_OVERTEMP_ALARM 9 BATTERY_FAILURE_ALARM 10 BATTERY_OVERTEMP_ALARM 11 PCMCIA_CARD_INSERTED_ALARM 12 PCMCIA_CARD_REMOVED_ALARM 13 SYS_SSMS_ARE_UPro
Integer32
.1.3.6.1.4.1.3199.10.28.1.1.1
ssg5000SlotTableA list of slot entries.
SEQUENCE OF Ssg5000SlotEntry
.1.3.6.1.4.1.3199.10.28.1.1.2
ssg5000SlotEntryEntry containing information about card status in a slot of the chassis. A slot could contain no card.
Ssg5000SlotEntry
.1.3.6.1.4.1.3199.10.28.1.1.2.1
ssg5000SlotIndexUnique index for indexing the slots.ro
Integer32
.1.3.6.1.4.1.3199.10.28.1.1.2.1.1
ssg5000SlotCardTypeThe type of card in the slot.ro
CardType
.1.3.6.1.4.1.3199.10.28.1.1.2.1.2
ssg5000SlotCardDescrA Description of the card in the slot.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3199.10.28.1.1.2.1.3
ssg5000SlotAdminStatusThe Administrative status of the card.ro
AdminStatus
.1.3.6.1.4.1.3199.10.28.1.1.2.1.4
ssg5000SlotOperStatusThe Operational status of the card.ro
OperStatus
.1.3.6.1.4.1.3199.10.28.1.1.2.1.5
ssg5000SlotCardNumPortsThe number of ports equipped in this card.ro
Integer32
.1.3.6.1.4.1.3199.10.28.1.1.2.1.6
ssg5000SlotCardHwVersionThe hardware version fo the card.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3199.10.28.1.1.2.1.7
ssg5000SlotCardSerialNumberThe serial number of the card.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3199.10.28.1.1.2.1.8
ssg5000SlotAlarmsThe bitmask value that carry card's alarms, Bit Alarm 1 CARD_MISSING_ALARM 2 CARD_INSERTED_ALARM 3 CARD_REMOVED_ALARM 4 CARD_MISMATCH_ALARM 5 CARD_BOOT_ALARM 6 CARD_REBOOT_ALARM 7 CARD_REV_MISMATCH_ALARM 8 CARD_FAILED_ALARM 9 CARD_MALFUNCTION_ALARM 10 CARD_FAILED_DIAG_ALARM 11 CARD_DEAD_ALARM 12 CARD_SWITCH_TO_ACTIVE 13 CARD_STANDBY_NOT_IN_REDUNDANTro
Integer32
.1.3.6.1.4.1.3199.10.28.1.1.2.1.9
ssg5000SSMStatTableTable of SSM port statistics information.
SEQUENCE OF Ssg5000SSMStatEntry
.1.3.6.1.4.1.3199.10.28.1.1.3
ssg5000SSMStatEntryAn entry in the table, containing information about a SSM port.
Ssg5000SSMStatEntry
.1.3.6.1.4.1.3199.10.28.1.1.3.1
ssg5000SSMIndexAn arbitrary integer value to uniquely identify a SSM module/port entry in a SSC card.ro
Integer32
.1.3.6.1.4.1.3199.10.28.1.1.3.1.1
ssg5000SSMAdminStatusA Administrative status of the SSM.ro
AdminStatus
.1.3.6.1.4.1.3199.10.28.1.1.3.1.2
ssg5000SSMOperStatusA Operational status of the SSM.ro
OperStatus
.1.3.6.1.4.1.3199.10.28.1.1.3.1.3
ssg5000SSMCPUIdleTics5SecCPU Idle Tics over 5 seconds duration of the SSM.ro
Integer32
.1.3.6.1.4.1.3199.10.28.1.1.3.1.4
ssg5000SSMCPUTics5SecCPU Tics over 5 seconds duration of the SSM.ro
Integer32
.1.3.6.1.4.1.3199.10.28.1.1.3.1.5
ssg5000SSMCPUIdleTicsRebootCPU Idle Tics since reboot of the SSM.ro
Integer32
.1.3.6.1.4.1.3199.10.28.1.1.3.1.6
ssg5000SSMCPUTicsRebootCPU Tics since reboot of the SSM.ro
Integer32
.1.3.6.1.4.1.3199.10.28.1.1.3.1.7
ssg5000SSMCPUMemHeapFreeFree Memory in the Heap of the the SSM.ro
Integer32
.1.3.6.1.4.1.3199.10.28.1.1.3.1.8
ssg5000SSMCPUMemHeapTotalTotal Memory in the Heap of the the SSM.ro
Integer32
.1.3.6.1.4.1.3199.10.28.1.1.3.1.9
ssg5000SSMCPUMBufClusterFreeFree MBuf cluster in the CPU of the SSM.ro
Integer32
.1.3.6.1.4.1.3199.10.28.1.1.3.1.10
ssg5000SSMCPUMBufClusterTotalTotal MBuf cluster in the CPU of the SSM.ro
Integer32
.1.3.6.1.4.1.3199.10.28.1.1.3.1.11
ssg5000SSMActiveAccessConnNumber of Active Access connection on this SSM.ro
Integer32
.1.3.6.1.4.1.3199.10.28.1.1.3.1.12
ssg5000SSMActiveSubscribersNumber of Active subscribers on this SSM.ro
Integer32
.1.3.6.1.4.1.3199.10.28.1.1.3.1.13
ssg5000SSMPacketsDroppedNumber of packets been dropped from this SSM.ro
Integer32
.1.3.6.1.4.1.3199.10.28.1.1.3.1.14
ssg5000SSMPacketsForwardedNumber of packets been forwarded from this SSM.ro
Integer32
.1.3.6.1.4.1.3199.10.28.1.1.3.1.15
ssg5000SSMAlarmsThe bitmask value that carry SSM's alarms, Bit Alarm 1 SSM_FAILED_ALARM 2 SSM_RESET_ALARM 3 SSM_UP_ALARM 4 SSM_DIED_ALARM 5 SSM_DOWN_ALARMro
Integer32
.1.3.6.1.4.1.3199.10.28.1.1.3.1.16
ssg5000ALCPortStatTableTable of port (ATM Line Card) statistics information, table will list instances of OC3, DS3/E3 not ETH, CT3
SEQUENCE OF Ssg5000ALCPortStatEntry
.1.3.6.1.4.1.3199.10.28.1.1.4
ssg5000ALCPortStatEntryAn entry in the table, containing information about an ATM access or trunk port.
Ssg5000ALCPortStatEntry
.1.3.6.1.4.1.3199.10.28.1.1.4.1
ssg5000ALCPortIndexThe ALC port index of an ALC card.ro
Integer32
.1.3.6.1.4.1.3199.10.28.1.1.4.1.1
ssg5000ALCPortIfIndexThe MIBII ifIndex value assigned to this port.ro
Integer32
.1.3.6.1.4.1.3199.10.28.1.1.4.1.2
ssg5000ALCPortAdminStatusThe Administrative status of the ALC port.ro
AdminStatus
.1.3.6.1.4.1.3199.10.28.1.1.4.1.3
ssg5000ALCPortOperStatusThe Operational status of the ALC port.ro
OperStatus
.1.3.6.1.4.1.3199.10.28.1.1.4.1.4
ssg5000ALCPortActiveAccessConnThe Active Access connections on the ALC port.ro
Integer32
.1.3.6.1.4.1.3199.10.28.1.1.4.1.5
ssg5000ALCPortActiveTrunkConnThe Active Trunk connections on the ALC port.ro
Integer32
.1.3.6.1.4.1.3199.10.28.1.1.4.1.6
ssg5000ALCPortCellsReceivedThe ATM cells received on this ALC port.ro
Counter64
.1.3.6.1.4.1.3199.10.28.1.1.4.1.7
ssg5000ALCPortCellsTransmittedThe ATM cells transmitted on this ALC port.ro
Counter64
.1.3.6.1.4.1.3199.10.28.1.1.4.1.8
ssg5000ALCPortCellsDroppedThe ATM cells dropped on this ALC port.ro
Counter64
.1.3.6.1.4.1.3199.10.28.1.1.4.1.9
ssg5000ALCPortAlarmsThe bitmask value that carry port's alarms, bitmap [32,... ,9,8,7,6,5,4,3,2,1], refer ALCPortAlarmType for ATM interface alarm acronyms. Bit Alarm 1 ALC_PORT_UP_ALARM 2 ALC_PORT_DOWN_ALARM 3 ALC_PORT_LOOP_ALARM 4 ALC_PORT_LOS_ALARM 5 ALC_PORT_LOF_ALARM 6 ALC_PORT_LAIS_ALARM 7 ALC_PORT_LRDI_ALARM 8 ALC_PORT_LOP_ALARM 9 ALC_PORT_PAIS_ALARM 10 ALC_PORT_PRDI_ALARM 11 ALC_PORT_LCD_ALARMro
Integer32
.1.3.6.1.4.1.3199.10.28.1.1.4.1.10
ssg5000ETHPortStatTableTable of ETH port information, table will list instances of ETH port.
SEQUENCE OF Ssg5000ETHPortStatEntry
.1.3.6.1.4.1.3199.10.28.1.1.5
ssg5000ETHPortStatEntryAn entry in the table, containing information about an Ethernet port.
Ssg5000ETHPortStatEntry
.1.3.6.1.4.1.3199.10.28.1.1.5.1
ssg5000ETHPortIndexThe ETH port index.ro
Integer32
.1.3.6.1.4.1.3199.10.28.1.1.5.1.1
ssg5000ETHPortAdminStatusThe Administrative status of the ETH port.ro
AdminStatus
.1.3.6.1.4.1.3199.10.28.1.1.5.1.2
ssg5000ETHPortOperStatusThe Operational status of the ETH port.ro
OperStatus
.1.3.6.1.4.1.3199.10.28.1.1.5.1.3
ssg5000ETHPortAlarmsThe bitmask value that ETH port's alarms, bitmap [32,... ,9,8,7,6,5,4,3,2,1], refer ETHPortAlarmType for alarm acronyms. Bit Alarm 1 ETH_LINK_DOWN_ALARM 2 ETH_LINK_UP_ALARMro
Integer32
.1.3.6.1.4.1.3199.10.28.1.1.5.1.4
ssg5000CT3PortStatTableTable of CT3 port information, table will list instances of CT3 port.
SEQUENCE OF Ssg5000CT3PortStatEntry
.1.3.6.1.4.1.3199.10.28.1.1.6
ssg5000CT3PortStatEntryAn entry in the table, containing information about an CT3 port.
Ssg5000CT3PortStatEntry
.1.3.6.1.4.1.3199.10.28.1.1.6.1
ssg5000CT3PortIndexThe CT3 port index.ro
Integer32
.1.3.6.1.4.1.3199.10.28.1.1.6.1.1
ssg5000CT3PortAdminStatusThe Administrative status of the CT3 port.ro
AdminStatus
.1.3.6.1.4.1.3199.10.28.1.1.6.1.2
ssg5000CT3PortOperStatusThe Operational status of the CT3 port.ro
OperStatus
.1.3.6.1.4.1.3199.10.28.1.1.6.1.3
ssg5000CT3PortAlarmsThe bitmask value that CT3 port's alarms, bitmap [32,... ,9,8,7,6,5,4,3,2,1], refer CT3PortAlarmType for alarm acronyms. Bit Alarm 1 CT3_FAILED_ALARM 2 CT3_RESET_ALARM 3 CT3_UP_ALARM 4 CT3_DIED_ALARM 5 CT3_DOWN_ALARM 6 CT3_DS3_LOS_ALARM 7 CT3_DS3_OOF_ALARM 8 CT3_DS3_AIS_ALARM 9 CT3_DS3_RERF_ALARM 10 CT3_DS3_RED_ALARMro
Integer32
.1.3.6.1.4.1.3199.10.28.1.1.6.1.4
ssg5000SysHealthGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.3199.10.28.1.2
ssg5000SysFanStatusStatus of fan.ro
PSOperStatus
.1.3.6.1.4.1.3199.10.28.1.2.1
ssg5000SysTempStatusok(1): 10C <= temperature <= 40C overTemperature(2): temperature > 40C underTemperature(3): temperature < 10C.ro
Enumeration
.1.3.6.1.4.1.3199.10.28.1.2.2
ssg5000SysFabricCellsDroppedNumber of ATM cells dropped at system fabric.ro
Counter64
.1.3.6.1.4.1.3199.10.28.1.2.3
ssg5000SysFabricMemUtilizationMemory utilization of system fabric.ro
Integer32
.1.3.6.1.4.1.3199.10.28.1.2.4
ssg5000SysActiveAccessConnNumber of active connections of access ports.ro
Integer32
.1.3.6.1.4.1.3199.10.28.1.2.5
ssg5000SysActiveTrunkConnNumber of active connections of trunk ports.ro
Integer32
.1.3.6.1.4.1.3199.10.28.1.2.6
ssg5000SysPacketsDroppedNumber of IP packets dropped of the system.ro
Integer32
.1.3.6.1.4.1.3199.10.28.1.2.7
ssg5000SysCellsDroppedNumber of ATM cells dropped of the system.ro
Counter64
.1.3.6.1.4.1.3199.10.28.1.2.8
ssg5000CmcCPUIdleTics5SecCMC's CPU Idle Tics over 5 seconds duration.ro
Integer32
.1.3.6.1.4.1.3199.10.28.1.2.9
ssg5000CmcCPUTotalTics5SecCMC's CPU Tics over 5 seconds duration.ro
Integer32
.1.3.6.1.4.1.3199.10.28.1.2.10
ssg5000CmcCPUIdleTicsRebootCMC's CPU Idle Tics since system reboot.ro
Integer32
.1.3.6.1.4.1.3199.10.28.1.2.11
ssg5000CmcCPUTotalTicsRebootCMC's CPU Tics since system reboot.ro
Integer32
.1.3.6.1.4.1.3199.10.28.1.2.12
ssg5000CmcCPUMemHeapFreeCMC's free memory Heap measurement.ro
Integer32
.1.3.6.1.4.1.3199.10.28.1.2.13
ssg5000CmcCPUMemHeapTotalCMC's total memory Heap measurement.ro
Integer32
.1.3.6.1.4.1.3199.10.28.1.2.14
ssg5000CmcCPUMBufClusterFreeCMC's free MBuf Cluster.ro
Integer32
.1.3.6.1.4.1.3199.10.28.1.2.15
ssg5000CmcCPUMBufClusterTotalCMC's total MBuf Cluster.ro
Integer32
.1.3.6.1.4.1.3199.10.28.1.2.16
ssg5000CmcCPUAverageLoadSystem CMC's average cpu load (%).ro
Integer32
.1.3.6.1.4.1.3199.10.28.1.2.17
ssg5000SspCPUnoEncryptionAverageLoadSystem SSPs with no Encryption average cpu load (%).ro
Integer32
.1.3.6.1.4.1.3199.10.28.1.2.18
ssg5000SspCPUwEncryptionAverageLoadSystem SSPs with Encryption average cpu load (%).ro
Integer32
.1.3.6.1.4.1.3199.10.28.1.2.19
ssg5000TrapIndexGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.3199.10.28.1.3
ssg5000TrapSystemAlarmIdA trap ID object for system alarm.
SystemAlarmType
.1.3.6.1.4.1.3199.10.28.1.3.1
ssg5000TrapCardAlarmIdA trap ID object for card alarm.
CardAlarmType
.1.3.6.1.4.1.3199.10.28.1.3.2
ssg5000TrapALCPortAlarmIdA trap ID object for (ALC) port alarm.
ALCPortAlarmType
.1.3.6.1.4.1.3199.10.28.1.3.3
ssg5000TrapSSMAlarmIdA trap ID object for ssm alarm.
SSMAlarmType
.1.3.6.1.4.1.3199.10.28.1.3.4
ssg5000TrapSlotIdA trap slot ID for slot number.
Integer32
.1.3.6.1.4.1.3199.10.28.1.3.5
ssg5000TrapCardTypeA trap card ID for slot card type.
CardType
.1.3.6.1.4.1.3199.10.28.1.3.6
ssg5000TrapPortIdA trap port ID for port number.
Integer32
.1.3.6.1.4.1.3199.10.28.1.3.7
ssg5000TrapOccurClearTagA trap state indicating occur or clear.
ALARMStateType
.1.3.6.1.4.1.3199.10.28.1.3.8
ssg5000TrapPVCAlarmIdA trap connection alarm ID for PVC connection alarm.
PVCAlarmType
.1.3.6.1.4.1.3199.10.28.1.3.9
ssg5000TrapInterfaceNumberA trap interface ID for connection alarm.
Integer32
.1.3.6.1.4.1.3199.10.28.1.3.10
ssg5000TrapVPINumberA trap variable object for Connection VPI number.
Integer32
.1.3.6.1.4.1.3199.10.28.1.3.11
ssg5000TrapVCINumberA trap variable object for Connection VCI number.
Integer32
.1.3.6.1.4.1.3199.10.28.1.3.12
ssg5000TrapCT3PortAlarmIdA trap ID object for CT3 port alarm.
CT3PortAlarmType
.1.3.6.1.4.1.3199.10.28.1.3.13
ssg5000TrapETHPortAlarmIdA trap ID object for ETH port alarm.
ETHPortAlarmType
.1.3.6.1.4.1.3199.10.28.1.3.14
ssg5000TrapSSGHostAddressA trap ID object indicating the SSG this trap is origionated, this is needed and informational when the trap is forwarded by Nortel-Shasta's Service Creation System manager to 3rd Party NMS.
IpAddress
.1.3.6.1.4.1.3199.10.28.1.3.15
ssg5000TrapCT3DS2AlarmIdA trap ID object for CT3 DS2 alarm.
CT3DS2AlarmType
.1.3.6.1.4.1.3199.10.28.1.3.16
ssg5000TrapCT3DS1AlarmIdA trap ID object for CT3 DS1 alarm.
CT3DS1AlarmType
.1.3.6.1.4.1.3199.10.28.1.3.17
ssg5000TrapDS2ChannelIdA trap ID object for indicating a DS2 channel.
Integer32
.1.3.6.1.4.1.3199.10.28.1.3.18
ssg5000TrapDS1ChannelIdA trap ID object for indicating a DS1 channel.
Integer32
.1.3.6.1.4.1.3199.10.28.1.3.19
ssg5000TrapServiceModuleAlarmA trap object for showing a SSG Service Module.
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3199.10.28.1.3.20
ssg5000TrapServiceAlarmSeverityA trap object for indicating Service Alarm Severity.
ServiceAlarmSeverityType
.1.3.6.1.4.1.3199.10.28.1.3.21
ssg5000TrapServiceAlarmDescriptionA trap object for describing a Service Alarm.
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3199.10.28.1.3.22
ssg5000MIBNotificationPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.3199.10.28.2
ssg5000MIBNotification
OBJECT IDENTIFIER
.1.3.6.1.4.1.3199.10.28.2.0
ssg5000ChassisFailureNotificationThe notification signifies that the agent detects a change in the status of ps1, ps2, fan, chassis temperature.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3199.10.28.2.0.1
ssg5000SysAlarmNotificationThe notification signal the agenet detects an alarm status in the system.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3199.10.28.2.0.2
ssg5000CardAlarmNotificationThe notification signal the agenet detects an alarm status in the card.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3199.10.28.2.0.3
ssg5000PortAlarmNotificationThe notification signal the agenet detects an alarm status in the port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3199.10.28.2.0.4
ssg5000SSMAlarmNotificationThe notification signal the agenet detects an alarm status in the SSM.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3199.10.28.2.0.5
ssg5000PVCAlarmNotificationThe notification signifies that the agenet detects an alarm status in a PVC.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3199.10.28.2.0.6
ssg5000CT3PortAlarmNotificationThe notification signal the agenet detects an alarm status in the CT3 port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3199.10.28.2.0.7
ssg5000ETHPortAlarmNotificationThe notification signal the agenet detects an alarm status in the ETHERNET port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3199.10.28.2.0.8
ssg5000CT3DS2AlarmNotificationThe notification signal the agenet detects an DS2 alarm status in the CT3 port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3199.10.28.2.0.9
ssg5000CT3DS1AlarmNotificationThe notification signal the agenet detects an DS1 alarm status in the CT3 port.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3199.10.28.2.0.10
ssg5000ServiceAlarmNotificationThe notification signal the agenet detects an alarm in SSG Service related modules.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3199.10.28.2.0.11
ssg5000ChassisMIBConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.3199.10.28.3
ssg5000ChassisMIBCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.3199.10.28.3.1
ssg5000ChassisMIBComplianceThe compliance statement for the SSG-5000, used in the CMC, which implements the SSG-5000 chassis MIB.
Unknown
.1.3.6.1.4.1.3199.10.28.3.1.1
ssg5000ChassisMIBGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.3199.10.28.3.2
ssg5000ChassisMIBGroupA collection of objects providing SSG-5000 chassis information.
Unknown
.1.3.6.1.4.1.3199.10.28.3.2.1
ssg5000SysHealthMIBGroupA collection of objects providing SSG-5000 health information.
Unknown
.1.3.6.1.4.1.3199.10.28.3.2.2
SSG-5000-CHASSIS-MIB - SNMP MIB Reference | MIBs Explorer