SSG-5000-CHASSIS-MIB
AI MIB Summary
The SSG-5000-CHASSIS-MIB monitors the physical health and operational status of Juniper Networks SSG-5000 series security gateways, tracking critical chassis-level metrics such as power supply states, fan speeds, temperature sensors, and system module availability.
This MIB provides a means to monitor the status of a SSG system's health.
Main OID:
ssg5000ChassisMIB.1.3.6.1.4.1.3199.10.28
119
Objects
Active
Status
5
Dependencies
Imported Objects
Objects
119 total| Object Name |
|---|
ssg5000ChassisMIBThis MIB provides a means to monitor the status of a SSG system's health. MODULE-IDENTITY .1.3.6.1.4.1.3199.10.28 |
ssg5000ChassisMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.3199.10.28.1 |
ssg5000ChassisGroup OBJECT IDENTIFIER .1.3.6.1.4.1.3199.10.28.1.1 |
ssg5000SysStatusThis is a bitmask value that indicates the system alarms: Bit Alarm 1 NODE_DEAD_ALARM 2 NODE_REBOOT_ALARM 3 FAN_DEAD_ALARM 4 FAN_FAILURE_ALARM 5 OVERTEMP_ALARM 6 DC_POWER_FAILURE_ALARM 7 AC_DC_SHELF_FAILURE_ALARM 8 AC_DC_SHELF_OVERTEMP_ALARM 9 BATTERY_FAILURE_ALARM 10 BATTERY_OVERTEMP_ALARM 11 PCMCIA_CARD_INSERTED_ALARM 12 PCMCIA_CARD_REMOVED_ALARM 13 SYS_SSMS_ARE_UPro Integer32 .1.3.6.1.4.1.3199.10.28.1.1.1 |
ssg5000SlotTableA list of slot entries. SEQUENCE OF Ssg5000SlotEntry .1.3.6.1.4.1.3199.10.28.1.1.2 |
ssg5000SlotEntryEntry containing information about card status in a slot of the chassis. A slot could contain no card. Ssg5000SlotEntry .1.3.6.1.4.1.3199.10.28.1.1.2.1 |
ssg5000SlotIndexUnique index for indexing the slots.ro Integer32 .1.3.6.1.4.1.3199.10.28.1.1.2.1.1 |
ssg5000SlotCardTypeThe type of card in the slot.ro CardType .1.3.6.1.4.1.3199.10.28.1.1.2.1.2 |
ssg5000SlotCardDescrA Description of the card in the slot.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3199.10.28.1.1.2.1.3 |
ssg5000SlotAdminStatusThe Administrative status of the card.ro AdminStatus .1.3.6.1.4.1.3199.10.28.1.1.2.1.4 |
ssg5000SlotOperStatusThe Operational status of the card.ro OperStatus .1.3.6.1.4.1.3199.10.28.1.1.2.1.5 |
ssg5000SlotCardNumPortsThe number of ports equipped in this card.ro Integer32 .1.3.6.1.4.1.3199.10.28.1.1.2.1.6 |
ssg5000SlotCardHwVersionThe hardware version fo the card.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3199.10.28.1.1.2.1.7 |
ssg5000SlotCardSerialNumberThe serial number of the card.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3199.10.28.1.1.2.1.8 |
ssg5000SlotAlarmsThe bitmask value that carry card's alarms, Bit Alarm 1 CARD_MISSING_ALARM 2 CARD_INSERTED_ALARM 3 CARD_REMOVED_ALARM 4 CARD_MISMATCH_ALARM 5 CARD_BOOT_ALARM 6 CARD_REBOOT_ALARM 7 CARD_REV_MISMATCH_ALARM 8 CARD_FAILED_ALARM 9 CARD_MALFUNCTION_ALARM 10 CARD_FAILED_DIAG_ALARM 11 CARD_DEAD_ALARM 12 CARD_SWITCH_TO_ACTIVE 13 CARD_STANDBY_NOT_IN_REDUNDANTro Integer32 .1.3.6.1.4.1.3199.10.28.1.1.2.1.9 |
ssg5000SSMStatTableTable of SSM port statistics information. SEQUENCE OF Ssg5000SSMStatEntry .1.3.6.1.4.1.3199.10.28.1.1.3 |
ssg5000SSMStatEntryAn entry in the table, containing information about a SSM port. Ssg5000SSMStatEntry .1.3.6.1.4.1.3199.10.28.1.1.3.1 |
ssg5000SSMIndexAn arbitrary integer value to uniquely identify a SSM module/port entry in a SSC card.ro Integer32 .1.3.6.1.4.1.3199.10.28.1.1.3.1.1 |
ssg5000SSMAdminStatusA Administrative status of the SSM.ro AdminStatus .1.3.6.1.4.1.3199.10.28.1.1.3.1.2 |
ssg5000SSMOperStatusA Operational status of the SSM.ro OperStatus .1.3.6.1.4.1.3199.10.28.1.1.3.1.3 |
ssg5000SSMCPUIdleTics5SecCPU Idle Tics over 5 seconds duration of the SSM.ro Integer32 .1.3.6.1.4.1.3199.10.28.1.1.3.1.4 |
ssg5000SSMCPUTics5SecCPU Tics over 5 seconds duration of the SSM.ro Integer32 .1.3.6.1.4.1.3199.10.28.1.1.3.1.5 |
ssg5000SSMCPUIdleTicsRebootCPU Idle Tics since reboot of the SSM.ro Integer32 .1.3.6.1.4.1.3199.10.28.1.1.3.1.6 |
ssg5000SSMCPUTicsRebootCPU Tics since reboot of the SSM.ro Integer32 .1.3.6.1.4.1.3199.10.28.1.1.3.1.7 |
ssg5000SSMCPUMemHeapFreeFree Memory in the Heap of the the SSM.ro Integer32 .1.3.6.1.4.1.3199.10.28.1.1.3.1.8 |
ssg5000SSMCPUMemHeapTotalTotal Memory in the Heap of the the SSM.ro Integer32 .1.3.6.1.4.1.3199.10.28.1.1.3.1.9 |
ssg5000SSMCPUMBufClusterFreeFree MBuf cluster in the CPU of the SSM.ro Integer32 .1.3.6.1.4.1.3199.10.28.1.1.3.1.10 |
ssg5000SSMCPUMBufClusterTotalTotal MBuf cluster in the CPU of the SSM.ro Integer32 .1.3.6.1.4.1.3199.10.28.1.1.3.1.11 |
ssg5000SSMActiveAccessConnNumber of Active Access connection on this SSM.ro Integer32 .1.3.6.1.4.1.3199.10.28.1.1.3.1.12 |
ssg5000SSMActiveSubscribersNumber of Active subscribers on this SSM.ro Integer32 .1.3.6.1.4.1.3199.10.28.1.1.3.1.13 |
ssg5000SSMPacketsDroppedNumber of packets been dropped from this SSM.ro Integer32 .1.3.6.1.4.1.3199.10.28.1.1.3.1.14 |
ssg5000SSMPacketsForwardedNumber of packets been forwarded from this SSM.ro Integer32 .1.3.6.1.4.1.3199.10.28.1.1.3.1.15 |
ssg5000SSMAlarmsThe bitmask value that carry SSM's alarms, Bit Alarm 1 SSM_FAILED_ALARM 2 SSM_RESET_ALARM 3 SSM_UP_ALARM 4 SSM_DIED_ALARM 5 SSM_DOWN_ALARMro Integer32 .1.3.6.1.4.1.3199.10.28.1.1.3.1.16 |
ssg5000ALCPortStatTableTable of port (ATM Line Card) statistics information, table will list instances of OC3, DS3/E3 not ETH, CT3 SEQUENCE OF Ssg5000ALCPortStatEntry .1.3.6.1.4.1.3199.10.28.1.1.4 |
ssg5000ALCPortStatEntryAn entry in the table, containing information about an ATM access or trunk port. Ssg5000ALCPortStatEntry .1.3.6.1.4.1.3199.10.28.1.1.4.1 |
ssg5000ALCPortIndexThe ALC port index of an ALC card.ro Integer32 .1.3.6.1.4.1.3199.10.28.1.1.4.1.1 |
ssg5000ALCPortIfIndexThe MIBII ifIndex value assigned to this port.ro Integer32 .1.3.6.1.4.1.3199.10.28.1.1.4.1.2 |
ssg5000ALCPortAdminStatusThe Administrative status of the ALC port.ro AdminStatus .1.3.6.1.4.1.3199.10.28.1.1.4.1.3 |
ssg5000ALCPortOperStatusThe Operational status of the ALC port.ro OperStatus .1.3.6.1.4.1.3199.10.28.1.1.4.1.4 |
ssg5000ALCPortActiveAccessConnThe Active Access connections on the ALC port.ro Integer32 .1.3.6.1.4.1.3199.10.28.1.1.4.1.5 |
ssg5000ALCPortActiveTrunkConnThe Active Trunk connections on the ALC port.ro Integer32 .1.3.6.1.4.1.3199.10.28.1.1.4.1.6 |
ssg5000ALCPortCellsReceivedThe ATM cells received on this ALC port.ro Counter64 .1.3.6.1.4.1.3199.10.28.1.1.4.1.7 |
ssg5000ALCPortCellsTransmittedThe ATM cells transmitted on this ALC port.ro Counter64 .1.3.6.1.4.1.3199.10.28.1.1.4.1.8 |
ssg5000ALCPortCellsDroppedThe ATM cells dropped on this ALC port.ro Counter64 .1.3.6.1.4.1.3199.10.28.1.1.4.1.9 |
ssg5000ALCPortAlarmsThe bitmask value that carry port's alarms, bitmap [32,... ,9,8,7,6,5,4,3,2,1], refer ALCPortAlarmType for ATM interface alarm acronyms. Bit Alarm 1 ALC_PORT_UP_ALARM 2 ALC_PORT_DOWN_ALARM 3 ALC_PORT_LOOP_ALARM 4 ALC_PORT_LOS_ALARM 5 ALC_PORT_LOF_ALARM 6 ALC_PORT_LAIS_ALARM 7 ALC_PORT_LRDI_ALARM 8 ALC_PORT_LOP_ALARM 9 ALC_PORT_PAIS_ALARM 10 ALC_PORT_PRDI_ALARM 11 ALC_PORT_LCD_ALARMro Integer32 .1.3.6.1.4.1.3199.10.28.1.1.4.1.10 |
ssg5000ETHPortStatTableTable of ETH port information, table will list instances of ETH port. SEQUENCE OF Ssg5000ETHPortStatEntry .1.3.6.1.4.1.3199.10.28.1.1.5 |
ssg5000ETHPortStatEntryAn entry in the table, containing information about an Ethernet port. Ssg5000ETHPortStatEntry .1.3.6.1.4.1.3199.10.28.1.1.5.1 |
ssg5000ETHPortIndexThe ETH port index.ro Integer32 .1.3.6.1.4.1.3199.10.28.1.1.5.1.1 |
ssg5000ETHPortAdminStatusThe Administrative status of the ETH port.ro AdminStatus .1.3.6.1.4.1.3199.10.28.1.1.5.1.2 |
ssg5000ETHPortOperStatusThe Operational status of the ETH port.ro OperStatus .1.3.6.1.4.1.3199.10.28.1.1.5.1.3 |
ssg5000ETHPortAlarmsThe bitmask value that ETH port's alarms, bitmap [32,... ,9,8,7,6,5,4,3,2,1], refer ETHPortAlarmType for alarm acronyms. Bit Alarm 1 ETH_LINK_DOWN_ALARM 2 ETH_LINK_UP_ALARMro Integer32 .1.3.6.1.4.1.3199.10.28.1.1.5.1.4 |
ssg5000CT3PortStatTableTable of CT3 port information, table will list instances of CT3 port. SEQUENCE OF Ssg5000CT3PortStatEntry .1.3.6.1.4.1.3199.10.28.1.1.6 |
ssg5000CT3PortStatEntryAn entry in the table, containing information about an CT3 port. Ssg5000CT3PortStatEntry .1.3.6.1.4.1.3199.10.28.1.1.6.1 |
ssg5000CT3PortIndexThe CT3 port index.ro Integer32 .1.3.6.1.4.1.3199.10.28.1.1.6.1.1 |
ssg5000CT3PortAdminStatusThe Administrative status of the CT3 port.ro AdminStatus .1.3.6.1.4.1.3199.10.28.1.1.6.1.2 |
ssg5000CT3PortOperStatusThe Operational status of the CT3 port.ro OperStatus .1.3.6.1.4.1.3199.10.28.1.1.6.1.3 |
ssg5000CT3PortAlarmsThe bitmask value that CT3 port's alarms, bitmap [32,... ,9,8,7,6,5,4,3,2,1], refer CT3PortAlarmType for alarm acronyms. Bit Alarm 1 CT3_FAILED_ALARM 2 CT3_RESET_ALARM 3 CT3_UP_ALARM 4 CT3_DIED_ALARM 5 CT3_DOWN_ALARM 6 CT3_DS3_LOS_ALARM 7 CT3_DS3_OOF_ALARM 8 CT3_DS3_AIS_ALARM 9 CT3_DS3_RERF_ALARM 10 CT3_DS3_RED_ALARMro Integer32 .1.3.6.1.4.1.3199.10.28.1.1.6.1.4 |
ssg5000SysHealthGroup OBJECT IDENTIFIER .1.3.6.1.4.1.3199.10.28.1.2 |
ssg5000SysFanStatusStatus of fan.ro PSOperStatus .1.3.6.1.4.1.3199.10.28.1.2.1 |
ssg5000SysTempStatusok(1): 10C <= temperature <= 40C overTemperature(2): temperature > 40C underTemperature(3): temperature < 10C.ro Enumeration .1.3.6.1.4.1.3199.10.28.1.2.2 |
ssg5000SysFabricCellsDroppedNumber of ATM cells dropped at system fabric.ro Counter64 .1.3.6.1.4.1.3199.10.28.1.2.3 |
ssg5000SysFabricMemUtilizationMemory utilization of system fabric.ro Integer32 .1.3.6.1.4.1.3199.10.28.1.2.4 |
ssg5000SysActiveAccessConnNumber of active connections of access ports.ro Integer32 .1.3.6.1.4.1.3199.10.28.1.2.5 |
ssg5000SysActiveTrunkConnNumber of active connections of trunk ports.ro Integer32 .1.3.6.1.4.1.3199.10.28.1.2.6 |
ssg5000SysPacketsDroppedNumber of IP packets dropped of the system.ro Integer32 .1.3.6.1.4.1.3199.10.28.1.2.7 |
ssg5000SysCellsDroppedNumber of ATM cells dropped of the system.ro Counter64 .1.3.6.1.4.1.3199.10.28.1.2.8 |
ssg5000CmcCPUIdleTics5SecCMC's CPU Idle Tics over 5 seconds duration.ro Integer32 .1.3.6.1.4.1.3199.10.28.1.2.9 |
ssg5000CmcCPUTotalTics5SecCMC's CPU Tics over 5 seconds duration.ro Integer32 .1.3.6.1.4.1.3199.10.28.1.2.10 |
ssg5000CmcCPUIdleTicsRebootCMC's CPU Idle Tics since system reboot.ro Integer32 .1.3.6.1.4.1.3199.10.28.1.2.11 |
ssg5000CmcCPUTotalTicsRebootCMC's CPU Tics since system reboot.ro Integer32 .1.3.6.1.4.1.3199.10.28.1.2.12 |
ssg5000CmcCPUMemHeapFreeCMC's free memory Heap measurement.ro Integer32 .1.3.6.1.4.1.3199.10.28.1.2.13 |
ssg5000CmcCPUMemHeapTotalCMC's total memory Heap measurement.ro Integer32 .1.3.6.1.4.1.3199.10.28.1.2.14 |
ssg5000CmcCPUMBufClusterFreeCMC's free MBuf Cluster.ro Integer32 .1.3.6.1.4.1.3199.10.28.1.2.15 |
ssg5000CmcCPUMBufClusterTotalCMC's total MBuf Cluster.ro Integer32 .1.3.6.1.4.1.3199.10.28.1.2.16 |
ssg5000CmcCPUAverageLoadSystem CMC's average cpu load (%).ro Integer32 .1.3.6.1.4.1.3199.10.28.1.2.17 |
ssg5000SspCPUnoEncryptionAverageLoadSystem SSPs with no Encryption average cpu load (%).ro Integer32 .1.3.6.1.4.1.3199.10.28.1.2.18 |
ssg5000SspCPUwEncryptionAverageLoadSystem SSPs with Encryption average cpu load (%).ro Integer32 .1.3.6.1.4.1.3199.10.28.1.2.19 |
ssg5000TrapIndexGroup OBJECT IDENTIFIER .1.3.6.1.4.1.3199.10.28.1.3 |
ssg5000TrapSystemAlarmIdA trap ID object for system alarm. SystemAlarmType .1.3.6.1.4.1.3199.10.28.1.3.1 |
ssg5000TrapCardAlarmIdA trap ID object for card alarm. CardAlarmType .1.3.6.1.4.1.3199.10.28.1.3.2 |
ssg5000TrapALCPortAlarmIdA trap ID object for (ALC) port alarm. ALCPortAlarmType .1.3.6.1.4.1.3199.10.28.1.3.3 |
ssg5000TrapSSMAlarmIdA trap ID object for ssm alarm. SSMAlarmType .1.3.6.1.4.1.3199.10.28.1.3.4 |
ssg5000TrapSlotIdA trap slot ID for slot number. Integer32 .1.3.6.1.4.1.3199.10.28.1.3.5 |
ssg5000TrapCardTypeA trap card ID for slot card type. CardType .1.3.6.1.4.1.3199.10.28.1.3.6 |
ssg5000TrapPortIdA trap port ID for port number. Integer32 .1.3.6.1.4.1.3199.10.28.1.3.7 |
ssg5000TrapOccurClearTagA trap state indicating occur or clear. ALARMStateType .1.3.6.1.4.1.3199.10.28.1.3.8 |
ssg5000TrapPVCAlarmIdA trap connection alarm ID for PVC connection alarm. PVCAlarmType .1.3.6.1.4.1.3199.10.28.1.3.9 |
ssg5000TrapInterfaceNumberA trap interface ID for connection alarm. Integer32 .1.3.6.1.4.1.3199.10.28.1.3.10 |
ssg5000TrapVPINumberA trap variable object for Connection VPI number. Integer32 .1.3.6.1.4.1.3199.10.28.1.3.11 |
ssg5000TrapVCINumberA trap variable object for Connection VCI number. Integer32 .1.3.6.1.4.1.3199.10.28.1.3.12 |
ssg5000TrapCT3PortAlarmIdA trap ID object for CT3 port alarm. CT3PortAlarmType .1.3.6.1.4.1.3199.10.28.1.3.13 |
ssg5000TrapETHPortAlarmIdA trap ID object for ETH port alarm. ETHPortAlarmType .1.3.6.1.4.1.3199.10.28.1.3.14 |
ssg5000TrapSSGHostAddressA trap ID object indicating the SSG this trap is origionated, this is needed and informational when the trap is forwarded by Nortel-Shasta's Service Creation System manager to 3rd Party NMS. IpAddress .1.3.6.1.4.1.3199.10.28.1.3.15 |
ssg5000TrapCT3DS2AlarmIdA trap ID object for CT3 DS2 alarm. CT3DS2AlarmType .1.3.6.1.4.1.3199.10.28.1.3.16 |
ssg5000TrapCT3DS1AlarmIdA trap ID object for CT3 DS1 alarm. CT3DS1AlarmType .1.3.6.1.4.1.3199.10.28.1.3.17 |
ssg5000TrapDS2ChannelIdA trap ID object for indicating a DS2 channel. Integer32 .1.3.6.1.4.1.3199.10.28.1.3.18 |
ssg5000TrapDS1ChannelIdA trap ID object for indicating a DS1 channel. Integer32 .1.3.6.1.4.1.3199.10.28.1.3.19 |
ssg5000TrapServiceModuleAlarmA trap object for showing a SSG Service Module. DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3199.10.28.1.3.20 |
ssg5000TrapServiceAlarmSeverityA trap object for indicating Service Alarm Severity. ServiceAlarmSeverityType .1.3.6.1.4.1.3199.10.28.1.3.21 |
ssg5000TrapServiceAlarmDescriptionA trap object for describing a Service Alarm. DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3199.10.28.1.3.22 |
ssg5000MIBNotificationPrefix OBJECT IDENTIFIER .1.3.6.1.4.1.3199.10.28.2 |
ssg5000MIBNotification OBJECT IDENTIFIER .1.3.6.1.4.1.3199.10.28.2.0 |
ssg5000ChassisFailureNotificationThe notification signifies that the agent detects a change in the status of ps1, ps2, fan, chassis temperature. NOTIFICATION-TYPE .1.3.6.1.4.1.3199.10.28.2.0.1 |
ssg5000SysAlarmNotificationThe notification signal the agenet detects an alarm status in the system. NOTIFICATION-TYPE .1.3.6.1.4.1.3199.10.28.2.0.2 |
ssg5000CardAlarmNotificationThe notification signal the agenet detects an alarm status in the card. NOTIFICATION-TYPE .1.3.6.1.4.1.3199.10.28.2.0.3 |
ssg5000PortAlarmNotificationThe notification signal the agenet detects an alarm status in the port. NOTIFICATION-TYPE .1.3.6.1.4.1.3199.10.28.2.0.4 |
ssg5000SSMAlarmNotificationThe notification signal the agenet detects an alarm status in the SSM. NOTIFICATION-TYPE .1.3.6.1.4.1.3199.10.28.2.0.5 |
ssg5000PVCAlarmNotificationThe notification signifies that the agenet detects an alarm status in a PVC. NOTIFICATION-TYPE .1.3.6.1.4.1.3199.10.28.2.0.6 |
ssg5000CT3PortAlarmNotificationThe notification signal the agenet detects an alarm status in the CT3 port. NOTIFICATION-TYPE .1.3.6.1.4.1.3199.10.28.2.0.7 |
ssg5000ETHPortAlarmNotificationThe notification signal the agenet detects an alarm status in the ETHERNET port. NOTIFICATION-TYPE .1.3.6.1.4.1.3199.10.28.2.0.8 |
ssg5000CT3DS2AlarmNotificationThe notification signal the agenet detects an DS2 alarm status in the CT3 port. NOTIFICATION-TYPE .1.3.6.1.4.1.3199.10.28.2.0.9 |
ssg5000CT3DS1AlarmNotificationThe notification signal the agenet detects an DS1 alarm status in the CT3 port. NOTIFICATION-TYPE .1.3.6.1.4.1.3199.10.28.2.0.10 |
ssg5000ServiceAlarmNotificationThe notification signal the agenet detects an alarm in SSG Service related modules. NOTIFICATION-TYPE .1.3.6.1.4.1.3199.10.28.2.0.11 |
ssg5000ChassisMIBConformance OBJECT IDENTIFIER .1.3.6.1.4.1.3199.10.28.3 |
ssg5000ChassisMIBCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.3199.10.28.3.1 |
ssg5000ChassisMIBComplianceThe compliance statement for the SSG-5000, used in the CMC, which implements the SSG-5000 chassis MIB. Unknown .1.3.6.1.4.1.3199.10.28.3.1.1 |
ssg5000ChassisMIBGroups OBJECT IDENTIFIER .1.3.6.1.4.1.3199.10.28.3.2 |
ssg5000ChassisMIBGroupA collection of objects providing SSG-5000 chassis information. Unknown .1.3.6.1.4.1.3199.10.28.3.2.1 |
ssg5000SysHealthMIBGroupA collection of objects providing SSG-5000 health information. Unknown .1.3.6.1.4.1.3199.10.28.3.2.2 |