SPSv1-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for SPSv1-MIB.
383
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
383 total| Object Name |
|---|
powertek OBJECT IDENTIFIER .1.3.6.1.4.1.42610 |
RFC1155-SMI Unknown .1.3.6.1.4.1.42610 |
product OBJECT IDENTIFIER .1.3.6.1.4.1.42610.1 |
pdu OBJECT IDENTIFIER .1.3.6.1.4.1.42610.1.4 |
sps OBJECT IDENTIFIER .1.3.6.1.4.1.42610.1.4.4 |
pduObjects OBJECT IDENTIFIER .1.3.6.1.4.1.42610.1.4.4.1 |
pduIdent OBJECT IDENTIFIER .1.3.6.1.4.1.42610.1.4.4.1.1 |
pduIdentAgentSoftwareVersionThe firmware version of the device.ro DisplayString .1.3.6.1.4.1.42610.1.4.4.1.1.1 |
pduIdentSerialNumberA Model of this device.ro DisplayString .1.3.6.1.4.1.42610.1.4.4.1.1.2 |
pduNetwork OBJECT IDENTIFIER .1.3.6.1.4.1.42610.1.4.4.1.2 |
pduNetworkTcpip OBJECT IDENTIFIER .1.3.6.1.4.1.42610.1.4.4.1.2.1 |
pduNetworkTcpipDhcpControlEnable/disable DHCP protocolrw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.2.1.1 |
pduNetworkTcpipIpv4 OBJECT IDENTIFIER .1.3.6.1.4.1.42610.1.4.4.1.2.1.2 |
pduNetworkTcpipIpv4AddressThe ip address that NMS can identify the managed device.rw IpAddress .1.3.6.1.4.1.42610.1.4.4.1.2.1.2.1 |
pduNetworkTcpipIpv4GatewayThe default gateway that allow device managed through routers.rw IpAddress .1.3.6.1.4.1.42610.1.4.4.1.2.1.2.2 |
pduNetworkTcpipIpv4SubnetInternet address subnet maskrw IpAddress .1.3.6.1.4.1.42610.1.4.4.1.2.1.2.3 |
pduNetworkTcpipIpv4PrimaryDNSInternet address of Primary DNS Serverrw IpAddress .1.3.6.1.4.1.42610.1.4.4.1.2.1.2.4 |
pduNetworkTcpipIpv4SecondaryDNSInternet address of Secondary DNSrw IpAddress .1.3.6.1.4.1.42610.1.4.4.1.2.1.2.5 |
pduNetworkTcpipIpv6 OBJECT IDENTIFIER .1.3.6.1.4.1.42610.1.4.4.1.2.1.3 |
pduNetworkTcpipIpv6ControlEnable/disable IPv6 protocolrw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.2.1.3.1 |
pduNetworkTcpipIpv6AutoConfigIPv6 Auto-config or Maual settingrw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.2.1.3.2 |
pduNetworkTcpipIpv6AddressThe ipv6 address that NMS can identify the managed device.ro DisplayString .1.3.6.1.4.1.42610.1.4.4.1.2.1.3.3 |
pduNetworkTcpipIpv6PrefixThe prefix length for ipv6 address.ro INTEGER .1.3.6.1.4.1.42610.1.4.4.1.2.1.3.4 |
pduNetworkTcpipIpv6RouterThe default gateway that allow device managed through routers.ro DisplayString .1.3.6.1.4.1.42610.1.4.4.1.2.1.3.5 |
pduNetworkTcpipIpv6PrimaryDNSInternet address of Primary DNS Serverrw DisplayString .1.3.6.1.4.1.42610.1.4.4.1.2.1.3.6 |
pduNetworkTcpipIpv6SecondaryDNSInternet address of Secondary DNSrw DisplayString .1.3.6.1.4.1.42610.1.4.4.1.2.1.3.7 |
pduNetworkSecurity OBJECT IDENTIFIER .1.3.6.1.4.1.42610.1.4.4.1.2.2 |
pduNetworkSecurityControlEnable/disable Network Access Protectionrw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.2.2.1 |
pduNetworkSecuritySsh OBJECT IDENTIFIER .1.3.6.1.4.1.42610.1.4.4.1.2.2.2 |
pduNetworkSecuritySshControlEnable/disable SSH Access Protectionrw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.2.2.2.1 |
pduNetworkSecuritySshIntervalDetecting Interval of SSH Access Protectionrw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.2.2.2.2 |
pduNetworkSecuritySshFailTimesUnsuccessful attempts of SSH Access Protectionrw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.2.2.2.3 |
pduNetworkSecuritySshBlockBlock Time of SSH Access Protectionrw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.2.2.2.4 |
pduNetworkSecuritySnmp OBJECT IDENTIFIER .1.3.6.1.4.1.42610.1.4.4.1.2.2.3 |
pduNetworkSecuritySnmpControlEnable/disable SNMP Access Protectionrw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.2.2.3.1 |
pduNetworkSecuritySnmpIntervalDetecting Interval of SNMP Access Protectionrw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.2.2.3.2 |
pduNetworkSecuritySnmpFailTimesUnsuccessful attempts of SNMP Access Protectionrw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.2.2.3.3 |
pduNetworkSecuritySnmpBlockBlock Time of SNMP Access Protectionrw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.2.2.3.4 |
pduNetworkSecurityHttp OBJECT IDENTIFIER .1.3.6.1.4.1.42610.1.4.4.1.2.2.4 |
pduNetworkSecurityHttpControlEnable/disable HTTP Access Protectionrw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.2.2.4.1 |
pduNetworkSecurityHttpIntervalDetecting Interval of HTTP Access Protectionrw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.2.2.4.2 |
pduNetworkSecurityHttpFailTimesUnsuccessful attempts of HTTP Access Protectionrw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.2.2.4.3 |
pduNetworkSecurityHttpBlockBlock Time of HTTP Access Protectionrw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.2.2.4.4 |
pduNetworkService OBJECT IDENTIFIER .1.3.6.1.4.1.42610.1.4.4.1.2.3 |
pduNetworkServiceSsh OBJECT IDENTIFIER .1.3.6.1.4.1.42610.1.4.4.1.2.3.1 |
pduNetworkServiceSshControlEnable/disable SSH Server Servicerw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.2.3.1.1 |
pduNetworkServiceSshPortThe Port Number of SSH Server Servicerw INTEGER .1.3.6.1.4.1.42610.1.4.4.1.2.3.1.2 |
pduNetworkServiceSsl OBJECT IDENTIFIER .1.3.6.1.4.1.42610.1.4.4.1.2.3.2 |
pduNetworkServiceSslControlEnable/disable HTTPs Server Servicerw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.2.3.2.1 |
pduNetworkServiceSslPortThe Port Number of HTTPs Server Servicerw INTEGER .1.3.6.1.4.1.42610.1.4.4.1.2.3.2.2 |
pduNetworkServiceSslForceForce use HTTPs Server Service only.rw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.2.3.2.3 |
pduNetworkServicePingControlEnable/disable to response to PING request.rw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.2.3.3 |
pduNetworkServiceRadius OBJECT IDENTIFIER .1.3.6.1.4.1.42610.1.4.4.1.2.3.4 |
pduNetworkServiceRadiusControlEnable/disable RADIUS Client Servicerw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.2.3.4.1 |
pduNetworkServiceRadiusIpThe IP Address of RADIUS Client Servicerw DisplayString .1.3.6.1.4.1.42610.1.4.4.1.2.3.4.2 |
pduNetworkServiceRadiusPortThe Port Number of RADIUS Client Servicerw INTEGER .1.3.6.1.4.1.42610.1.4.4.1.2.3.4.3 |
pduNetworkServiceRadiusSecretKeyThe Secret Key of RADIUS Client Servicerw DisplayString .1.3.6.1.4.1.42610.1.4.4.1.2.3.4.4 |
pduNetworkServiceRadiusTimeoutThe Timeout Interval of RADIUS Client Service in secondsrw INTEGER .1.3.6.1.4.1.42610.1.4.4.1.2.3.4.5 |
pduNetworkServiceRadiusRetryThe Retry Times of RADIUS Client Servicerw INTEGER .1.3.6.1.4.1.42610.1.4.4.1.2.3.4.6 |
pduSystem OBJECT IDENTIFIER .1.3.6.1.4.1.42610.1.4.4.1.3 |
pduSystemNameThe name of system.rw DisplayString .1.3.6.1.4.1.42610.1.4.4.1.3.1 |
pduSystemContactThe contact of system.rw DisplayString .1.3.6.1.4.1.42610.1.4.4.1.3.2 |
pduSystemLocationThe location of system.rw DisplayString .1.3.6.1.4.1.42610.1.4.4.1.3.3 |
pduSystemLogIntervalThe Log Interval of devicerw INTEGER .1.3.6.1.4.1.42610.1.4.4.1.3.4 |
pduSystemWebRefreshThe Web Refresh Interval of devicerw INTEGER .1.3.6.1.4.1.42610.1.4.4.1.3.5 |
pduSystemTime OBJECT IDENTIFIER .1.3.6.1.4.1.42610.1.4.4.1.3.6 |
pduSystemTimeDisplayThe date/time in agentro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.42610.1.4.4.1.3.6.1 |
pduSystemTimeZoneTime Zone to use when synchronize with NTP server.rw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.3.6.2 |
pduSystemTimeFormatDate Formatrw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.3.6.3 |
pduSystemTimeSettingTime Settingrw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.3.6.4 |
pduSystemTimeDayLightSavingEnable/disable the Day Light Saving when synchronize with NTP server.rw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.3.6.5 |
pduSystemTimeManual OBJECT IDENTIFIER .1.3.6.1.4.1.42610.1.4.4.1.3.6.6 |
pduSystemTimeManualDateThe date in agent, format is (dd/mm/yyyy)rw DisplayString .1.3.6.1.4.1.42610.1.4.4.1.3.6.6.1 |
pduSystemTimeManualTimeThe time in agent, format is (hh:mm:ss)rw DisplayString .1.3.6.1.4.1.42610.1.4.4.1.3.6.6.2 |
pduSystemTimeNtp OBJECT IDENTIFIER .1.3.6.1.4.1.42610.1.4.4.1.3.6.7 |
pduSystemTimeNtpControlEnable or disable the agent to synchronize date/time with NTP server.rw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.3.6.7.1 |
pduSystemTimeNtpServerThe ip address of NTP server.rw DisplayString .1.3.6.1.4.1.42610.1.4.4.1.3.6.7.2 |
pduSystemTimeNtpSyncIntervalThe Sync Interval with NTP server.rw INTEGER .1.3.6.1.4.1.42610.1.4.4.1.3.6.7.3 |
pduSystemTimeNtpSyncUnitThe Unit of Sync Intervalrw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.3.6.7.4 |
pduSystemResetToDefaultReset the parameter of PDU to default.rw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.3.7 |
pduSystemRebootReboot the system of PDU.rw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.3.8 |
pduSNMP OBJECT IDENTIFIER .1.3.6.1.4.1.42610.1.4.4.1.4 |
pduSnmpControlEnable/disable SNMP protocol.rw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.4.1 |
pduSnmpPortThe UDP port for SNMP.rw INTEGER .1.3.6.1.4.1.42610.1.4.4.1.4.2 |
pduSnmpVersionSet SNMP version.rw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.4.3 |
pduSnmpTrapsReceiversTableA list of managers to send traps to. The number of
entries is given by the value of pduSnmpNumTrapReceivers SEQUENCE OF PduSnmpTrapsReceiversEntry .1.3.6.1.4.1.42610.1.4.4.1.4.4 |
pduSnmpTrapsReceiversEntryThe managers to send traps to. PduSnmpTrapsReceiversEntry .1.3.6.1.4.1.42610.1.4.4.1.4.4.1 |
trapsIndexThe index to a trap receiver entry.ro INTEGER .1.3.6.1.4.1.42610.1.4.4.1.4.4.1.1 |
trapsReceiverAddrThe IP address of the manager to send a trap to.rw DisplayString .1.3.6.1.4.1.42610.1.4.4.1.4.4.1.2 |
receiverEventLevelThe severity level of traps to be received by this manager.rw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.4.4.1.3 |
receiverSnmpVerThe SNMP Trap version of trap receivers.rw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.4.4.1.4 |
receiverDescriptionDescription of trap receiversrw DisplayString .1.3.6.1.4.1.42610.1.4.4.1.4.4.1.5 |
pduEmail OBJECT IDENTIFIER .1.3.6.1.4.1.42610.1.4.4.1.5 |
pduEmailServerThe address of Email server.rw DisplayString .1.3.6.1.4.1.42610.1.4.4.1.5.1 |
pduEmailPortThe UDP port for Email Server.rw INTEGER .1.3.6.1.4.1.42610.1.4.4.1.5.2 |
pduEmailSenderEmailThe sender's Email addressrw DisplayString .1.3.6.1.4.1.42610.1.4.4.1.5.3 |
pduEmailPrefixThe prefix string of mail subjectrw DisplayString .1.3.6.1.4.1.42610.1.4.4.1.5.4 |
pduEmailAuthControlEnable/disable SMTP Authentication.rw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.5.5 |
pduEmailAuthUsernameThe user name of SMTP Authenticationrw DisplayString .1.3.6.1.4.1.42610.1.4.4.1.5.6 |
pduEmailAuthPasswordThe password of SMTP Authenticationrw DisplayString .1.3.6.1.4.1.42610.1.4.4.1.5.7 |
pduEmailReceiversTableA list of managers to send email notification to. SEQUENCE OF PduEmailReceiversEntry .1.3.6.1.4.1.42610.1.4.4.1.5.8 |
pduEmailReceiversEntryThe managers to send email notification to. PduEmailReceiversEntry .1.3.6.1.4.1.42610.1.4.4.1.5.8.1 |
mailRecvIndexThe index to a email notification receiver entry.ro INTEGER .1.3.6.1.4.1.42610.1.4.4.1.5.8.1.1 |
mailRecvReceiverAddrThe Email address of the manager to send a email notification to.rw DisplayString .1.3.6.1.4.1.42610.1.4.4.1.5.8.1.2 |
mailRecvEmailTypeThe Email Type of email notification receivers.rw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.5.8.1.3 |
mailRecvEventLevelThe severity level of email notification to be received by this manager.rw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.5.8.1.4 |
mailRecvDescriptionDescription of email notification receiversrw DisplayString .1.3.6.1.4.1.42610.1.4.4.1.5.8.1.5 |
pduPwrMonitoring OBJECT IDENTIFIER .1.3.6.1.4.1.42610.1.4.4.1.6 |
pduPwrMonitoringInlet OBJECT IDENTIFIER .1.3.6.1.4.1.42610.1.4.4.1.6.1 |
pduPwrMonitoringInletNumThe number of Inlet.ro INTEGER .1.3.6.1.4.1.42610.1.4.4.1.6.1.1 |
pduPwrMonitoringInletStatusTableA list to display status of Inlet. SEQUENCE OF PduPwrMonitoringInletStatusEntry .1.3.6.1.4.1.42610.1.4.4.1.6.1.2 |
pduPwrMonitoringInletStatusEntryA list to display status of Inlet. PduPwrMonitoringInletStatusEntry .1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1 |
inletIndexThe index to Inlet status entry.ro INTEGER .1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1.1 |
inletPowerAllThe total power of inlet.ro INTEGER UNITS "0.1W" .1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1.2 |
inletResetFromThe reset date of inlet.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1.3 |
inletEnergyThe total energy of inlet.ro INTEGER UNITS "KWh" .1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1.4 |
inletStatusThe Status of inlet.ro Enumeration .1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1.5 |
inletCurrPhase1The phase1 current of inlet.ro INTEGER UNITS "0.01A" .1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1.6 |
inletCurrPhase2The phase2 current of inlet.ro INTEGER UNITS "0.01A" .1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1.7 |
inletCurrPhase3The phase3 current of inlet.ro INTEGER UNITS "0.01A" .1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1.8 |
inletVoltPhase1The phase1 voltage of inlet.ro INTEGER UNITS "0.1V" .1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1.9 |
inletVoltPhase2The phase2 voltage of inlet.ro INTEGER UNITS "0.1V" .1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1.10 |
inletVoltPhase3The phase3 voltage of inlet.ro INTEGER UNITS "0.1V" .1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1.11 |
inletPwrFactorPhase1The phase1 power factor of inlet.ro INTEGER UNITS "0.1%" .1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1.12 |
inletPwrFactorPhase2The phase2 power factor of inlet.ro INTEGER UNITS "0.1%" .1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1.13 |
inletPwrFactorPhase3The phase3 power factor of inlet.ro INTEGER UNITS "0.1%" .1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1.14 |
inletPowerPhase1The phase1 power of inlet.ro INTEGER UNITS "0.1W" .1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1.15 |
inletPowerPhase2The phase2 power of inlet.ro INTEGER UNITS "0.1W" .1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1.16 |
inletPowerPhase3The phase3 power of inlet.ro INTEGER UNITS "0.1W" .1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1.17 |
inletStatusPhase1The phase1 status of inlet.ro Enumeration .1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1.18 |
inletStatusPhase2The phase2 status of inlet.ro Enumeration .1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1.19 |
inletStatusPhase3The phase3 status of inlet.ro Enumeration .1.3.6.1.4.1.42610.1.4.4.1.6.1.2.1.20 |
pduPwrMonitoringInletCfgTableA list to configure thresholds of inlet. SEQUENCE OF PduPwrMonitoringInletCfgEntry .1.3.6.1.4.1.42610.1.4.4.1.6.1.3 |
pduPwrMonitoringInletCfgEntryA list to configure thresholds of inlet. PduPwrMonitoringInletCfgEntry .1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1 |
inletCfgIndexThe index to inlet configuration entry.ro INTEGER .1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.1 |
inletCfgLoadCriticalThe Critical Threshold of inlet load.rw INTEGER UNITS "0.1kW" .1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.2 |
inletCfgLoadWarningThe Warning Threshold of inlet load.rw INTEGER UNITS "0.1kW" .1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.3 |
inletCfgCurrCritPhase1The Critical Threshold of pahse1 current of inlet.rw INTEGER UNITS "0.1A" .1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.4 |
inletCfgCurrCritPhase2The Critical Threshold of pahse2 current of inlet.rw INTEGER UNITS "0.1A" .1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.5 |
inletCfgCurrCritPhase3The Critical Threshold of pahse3 current of inlet.rw INTEGER UNITS "0.1A" .1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.6 |
inletCfgCurrWarnPhase1The Warning Threshold of pahse1 current of inlet.rw INTEGER UNITS "0.1A" .1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.7 |
inletCfgCurrWarnPhase2The Warning Threshold of pahse2 current of inlet.rw INTEGER UNITS "0.1A" .1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.8 |
inletCfgCurrWarnPhase3The Warning Threshold of pahse3 current of inlet.rw INTEGER UNITS "0.1A" .1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.9 |
inletCfgVoltCritPhase1The Critical Threshold of pahse1 voltage of inlet.rw INTEGER UNITS "0.1V" .1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.10 |
inletCfgVoltCritPhase2The Critical Threshold of pahse2 voltage of inlet.rw INTEGER UNITS "0.1V" .1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.11 |
inletCfgVoltCritPhase3The Critical Threshold of pahse3 voltage of inlet.rw INTEGER UNITS "0.1V" .1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.12 |
inletCfgVoltWarnPhase1The Warning Threshold of pahse1 voltage of inlet.rw INTEGER UNITS "0.1V" .1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.13 |
inletCfgVoltWarnPhase2The Warning Threshold of pahse2 voltage of inlet.rw INTEGER UNITS "0.1V" .1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.14 |
inletCfgVoltWarnPhase3The Warning Threshold of pahse3 voltage of inlet.rw INTEGER UNITS "0.1V" .1.3.6.1.4.1.42610.1.4.4.1.6.1.3.1.15 |
pduPwrMonitoringOutlet OBJECT IDENTIFIER .1.3.6.1.4.1.42610.1.4.4.1.6.2 |
pduPwrMonitoringOutletPduA OBJECT IDENTIFIER .1.3.6.1.4.1.42610.1.4.4.1.6.2.1 |
pduPwrMonitoringOutletNumPduAThe number of PduA Outlet.ro INTEGER .1.3.6.1.4.1.42610.1.4.4.1.6.2.1.1 |
pduPwrMonitoringOutletStatusTablePduAA list to display status of PduA outlet. SEQUENCE OF PduPwrMonitoringOutletStatusPduAEntry .1.3.6.1.4.1.42610.1.4.4.1.6.2.1.2 |
pduPwrMonitoringOutletStatusPduAEntryA list to display status of PduA outlet. PduPwrMonitoringOutletStatusPduAEntry .1.3.6.1.4.1.42610.1.4.4.1.6.2.1.2.1 |
outletPduAIndexThe index to outlet status of PduA.ro INTEGER .1.3.6.1.4.1.42610.1.4.4.1.6.2.1.2.1.1 |
outletPduAStateThe state of PduA outlet.ro Enumeration .1.3.6.1.4.1.42610.1.4.4.1.6.2.1.2.1.2 |
outletPduACurrentThe current of PduA outlet.ro INTEGER UNITS "0.01A" .1.3.6.1.4.1.42610.1.4.4.1.6.2.1.2.1.3 |
outletPduAPwrFactorThe power factor of PduA outlet.ro INTEGER UNITS "0.1%" .1.3.6.1.4.1.42610.1.4.4.1.6.2.1.2.1.4 |
outletPduAPowerThe power of PduA outlet.ro INTEGER UNITS "0.1W" .1.3.6.1.4.1.42610.1.4.4.1.6.2.1.2.1.5 |
outletPduAEnergyThe energy of PduA outlet.ro INTEGER UNITS "KWh" .1.3.6.1.4.1.42610.1.4.4.1.6.2.1.2.1.6 |
outletPduAResetFromThe reset date of PduA outlet.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.42610.1.4.4.1.6.2.1.2.1.7 |
outletPduAStatusThe status of PduA outlet.ro Enumeration .1.3.6.1.4.1.42610.1.4.4.1.6.2.1.2.1.8 |
pduPwrMonitoringOutletCfgTablePduAA list to display configuration of PduA outlet. SEQUENCE OF PduPwrMonitoringOutletCfgPduAEntry .1.3.6.1.4.1.42610.1.4.4.1.6.2.1.3 |
pduPwrMonitoringOutletCfgPduAEntryA list to display configuration of PduA outlet. PduPwrMonitoringOutletCfgPduAEntry .1.3.6.1.4.1.42610.1.4.4.1.6.2.1.3.1 |
outletCfgPduAIndexThe index to outlet configuration of PduA.ro INTEGER .1.3.6.1.4.1.42610.1.4.4.1.6.2.1.3.1.1 |
outletCfgPduANameThe name for outlet of PduA.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.42610.1.4.4.1.6.2.1.3.1.2 |
outletCfgPduADelayOnStatusThe Delay On status of PduA outlet.rw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.6.2.1.3.1.3 |
outletCfgPduADelayOnTimeThe Delay On time of PduA outlet.rw INTEGER UNITS "seconds" .1.3.6.1.4.1.42610.1.4.4.1.6.2.1.3.1.4 |
outletCfgPduADelayOffStatusThe Delay Off status of PduA outlet.rw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.6.2.1.3.1.5 |
outletCfgPduADelayOffTimeThe Delay Off time of PduA outlet.rw INTEGER UNITS "seconds" .1.3.6.1.4.1.42610.1.4.4.1.6.2.1.3.1.6 |
outletCfgPduARebootThe Delay On reboot duration of PduA outlet.rw INTEGER UNITS "seconds" .1.3.6.1.4.1.42610.1.4.4.1.6.2.1.3.1.7 |
outletCfgPduAOverCurrCriticalThe Critical Threshold of current of PduA outlet.rw INTEGER UNITS "0.1A" .1.3.6.1.4.1.42610.1.4.4.1.6.2.1.3.1.8 |
outletCfgPduAOverCurrWarningThe Warning Threshold of current of PduA outlet.rw INTEGER UNITS "0.1A" .1.3.6.1.4.1.42610.1.4.4.1.6.2.1.3.1.9 |
outletCfgPduAOverPwrCriticalThe Critical Threshold of power of PduA outlet.rw INTEGER UNITS "1W" .1.3.6.1.4.1.42610.1.4.4.1.6.2.1.3.1.10 |
outletCfgPduAOverPwrWarningThe Warning Threshold of power of PduA outlet.rw INTEGER UNITS "1W" .1.3.6.1.4.1.42610.1.4.4.1.6.2.1.3.1.11 |
pduPwrMonitoringOutletCtlTablePduAA list to display control of PduA outlet. SEQUENCE OF PduPwrMonitoringOutletCtlPduAEntry .1.3.6.1.4.1.42610.1.4.4.1.6.2.1.4 |
pduPwrMonitoringOutletCtlPduAEntryA list to display control of PduA outlet. PduPwrMonitoringOutletCtlPduAEntry .1.3.6.1.4.1.42610.1.4.4.1.6.2.1.4.1 |
outletCtlPduAIndexThe index to outlet control of PduA.ro INTEGER .1.3.6.1.4.1.42610.1.4.4.1.6.2.1.4.1.1 |
outletCtlPduAControlThe control-type of PduA outlet.rw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.6.2.1.4.1.2 |
pduPwrMonitoringOutletPduB OBJECT IDENTIFIER .1.3.6.1.4.1.42610.1.4.4.1.6.2.2 |
pduPwrMonitoringOutletNumPduBThe number of PduB Outlet.ro INTEGER .1.3.6.1.4.1.42610.1.4.4.1.6.2.2.1 |
pduPwrMonitoringOutletStatusTablePduBA list to display status of PduB outlet. SEQUENCE OF PduPwrMonitoringOutletStatusPduBEntry .1.3.6.1.4.1.42610.1.4.4.1.6.2.2.2 |
pduPwrMonitoringOutletStatusPduBEntryA list to display status of PduB outlet. PduPwrMonitoringOutletStatusPduBEntry .1.3.6.1.4.1.42610.1.4.4.1.6.2.2.2.1 |
outletPduBIndexThe index to outlet status of PduB.ro INTEGER .1.3.6.1.4.1.42610.1.4.4.1.6.2.2.2.1.1 |
outletPduBStateThe state of PduB outlet.ro Enumeration .1.3.6.1.4.1.42610.1.4.4.1.6.2.2.2.1.2 |
outletPduBCurrentThe current of PduB outlet.ro INTEGER UNITS "0.01A" .1.3.6.1.4.1.42610.1.4.4.1.6.2.2.2.1.3 |
outletPduBPwrFactorThe power factor of PduB outlet.ro INTEGER UNITS "0.1%" .1.3.6.1.4.1.42610.1.4.4.1.6.2.2.2.1.4 |
outletPduBPowerThe power of PduB outlet.ro INTEGER UNITS "0.1W" .1.3.6.1.4.1.42610.1.4.4.1.6.2.2.2.1.5 |
outletPduBEnergyThe energy of PduB outlet.ro INTEGER UNITS "KWh" .1.3.6.1.4.1.42610.1.4.4.1.6.2.2.2.1.6 |
outletPduBResetFromThe reset date of PduB outlet.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.42610.1.4.4.1.6.2.2.2.1.7 |
outletPduBStatusThe status of PduB outlet.ro Enumeration .1.3.6.1.4.1.42610.1.4.4.1.6.2.2.2.1.8 |
pduPwrMonitoringOutletCfgTablePduBA list to display configuration of PduB outlet. SEQUENCE OF PduPwrMonitoringOutletCfgPduBEntry .1.3.6.1.4.1.42610.1.4.4.1.6.2.2.3 |
pduPwrMonitoringOutletCfgPduBEntryA list to display configuration of PduB outlet. PduPwrMonitoringOutletCfgPduBEntry .1.3.6.1.4.1.42610.1.4.4.1.6.2.2.3.1 |
outletCfgPduBIndexThe index to outlet configuration of PduB.ro INTEGER .1.3.6.1.4.1.42610.1.4.4.1.6.2.2.3.1.1 |
outletCfgPduBNameThe name for outlet of PduB.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.42610.1.4.4.1.6.2.2.3.1.2 |
outletCfgPduBDelayOnStatusThe Delay On status of PduB outlet.rw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.6.2.2.3.1.3 |
outletCfgPduBDelayOnTimeThe Delay On time of PduB outlet.rw INTEGER UNITS "seconds" .1.3.6.1.4.1.42610.1.4.4.1.6.2.2.3.1.4 |
outletCfgPduBDelayOffStatusThe Delay Off status of PduB outlet.rw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.6.2.2.3.1.5 |
outletCfgPduBDelayOffTimeThe Delay Off time of PduB outlet.rw INTEGER UNITS "seconds" .1.3.6.1.4.1.42610.1.4.4.1.6.2.2.3.1.6 |
outletCfgPduBRebootThe Delay On reboot duration of PduB outlet.rw INTEGER UNITS "seconds" .1.3.6.1.4.1.42610.1.4.4.1.6.2.2.3.1.7 |
outletCfgPduBOverCurrCriticalThe Critical Threshold of current of PduB outlet.rw INTEGER UNITS "0.1A" .1.3.6.1.4.1.42610.1.4.4.1.6.2.2.3.1.8 |
outletCfgPduBOverCurrWarningThe Warning Threshold of current of PduB outlet.rw INTEGER UNITS "0.1A" .1.3.6.1.4.1.42610.1.4.4.1.6.2.2.3.1.9 |
outletCfgPduBOverPwrCriticalThe Critical Threshold of power of PduB outlet.rw INTEGER UNITS "1W" .1.3.6.1.4.1.42610.1.4.4.1.6.2.2.3.1.10 |
outletCfgPduBOverPwrWarningThe Warning Threshold of power of PduB outlet.rw INTEGER UNITS "1W" .1.3.6.1.4.1.42610.1.4.4.1.6.2.2.3.1.11 |
pduPwrMonitoringOutletCtlTablePduBA list to display control of PduB outlet. SEQUENCE OF PduPwrMonitoringOutletCtlPduBEntry .1.3.6.1.4.1.42610.1.4.4.1.6.2.2.4 |
pduPwrMonitoringOutletCtlPduBEntryA list to display control of PduB outlet. PduPwrMonitoringOutletCtlPduBEntry .1.3.6.1.4.1.42610.1.4.4.1.6.2.2.4.1 |
outletCtlPduBIndexThe index to outlet control of PduB.ro INTEGER .1.3.6.1.4.1.42610.1.4.4.1.6.2.2.4.1.1 |
outletCtlPduBControlThe control-type of PduB outlet.rw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.6.2.2.4.1.2 |
pduPwrMonitoringOutletPduC OBJECT IDENTIFIER .1.3.6.1.4.1.42610.1.4.4.1.6.2.3 |
pduPwrMonitoringOutletNumPduCThe number of PduC Outlet.ro INTEGER .1.3.6.1.4.1.42610.1.4.4.1.6.2.3.1 |
pduPwrMonitoringOutletStatusTablePduCA list to display status of PduC outlet. SEQUENCE OF PduPwrMonitoringOutletStatusPduCEntry .1.3.6.1.4.1.42610.1.4.4.1.6.2.3.2 |
pduPwrMonitoringOutletStatusPduCEntryA list to display status of PduC outlet. PduPwrMonitoringOutletStatusPduCEntry .1.3.6.1.4.1.42610.1.4.4.1.6.2.3.2.1 |
outletPduCIndexThe index to outlet status of PduC.ro INTEGER .1.3.6.1.4.1.42610.1.4.4.1.6.2.3.2.1.1 |
outletPduCStateThe state of PduC outlet.ro Enumeration .1.3.6.1.4.1.42610.1.4.4.1.6.2.3.2.1.2 |
outletPduCCurrentThe current of PduC outlet.ro INTEGER UNITS "0.01A" .1.3.6.1.4.1.42610.1.4.4.1.6.2.3.2.1.3 |
outletPduCPwrFactorThe power factor of PduC outlet.ro INTEGER UNITS "0.1%" .1.3.6.1.4.1.42610.1.4.4.1.6.2.3.2.1.4 |
outletPduCPowerThe power of PduC outlet.ro INTEGER UNITS "0.1W" .1.3.6.1.4.1.42610.1.4.4.1.6.2.3.2.1.5 |
outletPduCEnergyThe energy of PduC outlet.ro INTEGER UNITS "KWh" .1.3.6.1.4.1.42610.1.4.4.1.6.2.3.2.1.6 |
outletPduCResetFromThe reset date of PduC outlet.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.42610.1.4.4.1.6.2.3.2.1.7 |
outletPduCStatusThe status of PduC outlet.ro Enumeration .1.3.6.1.4.1.42610.1.4.4.1.6.2.3.2.1.8 |
pduPwrMonitoringOutletCfgTablePduCA list to display configuration of PduC outlet. SEQUENCE OF PduPwrMonitoringOutletCfgPduCEntry .1.3.6.1.4.1.42610.1.4.4.1.6.2.3.3 |
pduPwrMonitoringOutletCfgPduCEntryA list to display configuration of PduC outlet. PduPwrMonitoringOutletCfgPduCEntry .1.3.6.1.4.1.42610.1.4.4.1.6.2.3.3.1 |
outletCfgPduCIndexThe index to outlet configuration of PduC.ro INTEGER .1.3.6.1.4.1.42610.1.4.4.1.6.2.3.3.1.1 |
outletCfgPduCNameThe name for outlet of PduC.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.42610.1.4.4.1.6.2.3.3.1.2 |
outletCfgPduCDelayOnStatusThe Delay On status of PduC outlet.rw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.6.2.3.3.1.3 |
outletCfgPduCDelayOnTimeThe Delay On time of PduC outlet.rw INTEGER UNITS "seconds" .1.3.6.1.4.1.42610.1.4.4.1.6.2.3.3.1.4 |
outletCfgPduCDelayOffStatusThe Delay Off status of PduC outlet.rw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.6.2.3.3.1.5 |
outletCfgPduCDelayOffTimeThe Delay Off time of PduC outlet.rw INTEGER UNITS "seconds" .1.3.6.1.4.1.42610.1.4.4.1.6.2.3.3.1.6 |
outletCfgPduCRebootThe Delay On reboot duration of PduC outlet.rw INTEGER UNITS "seconds" .1.3.6.1.4.1.42610.1.4.4.1.6.2.3.3.1.7 |
outletCfgPduCOverCurrCriticalThe Critical Threshold of current of PduC outlet.rw INTEGER UNITS "0.1A" .1.3.6.1.4.1.42610.1.4.4.1.6.2.3.3.1.8 |
outletCfgPduCOverCurrWarningThe Warning Threshold of current of PduC outlet.rw INTEGER UNITS "0.1A" .1.3.6.1.4.1.42610.1.4.4.1.6.2.3.3.1.9 |
outletCfgPduCOverPwrCriticalThe Critical Threshold of power of PduC outlet.rw INTEGER UNITS "1W" .1.3.6.1.4.1.42610.1.4.4.1.6.2.3.3.1.10 |
outletCfgPduCOverPwrWarningThe Warning Threshold of power of PduC outlet.rw INTEGER UNITS "1W" .1.3.6.1.4.1.42610.1.4.4.1.6.2.3.3.1.11 |
pduPwrMonitoringOutletCtlTablePduCA list to display control of PduC outlet. SEQUENCE OF PduPwrMonitoringOutletCtlPduCEntry .1.3.6.1.4.1.42610.1.4.4.1.6.2.3.4 |
pduPwrMonitoringOutletCtlPduCEntryA list to display control of PduC outlet. PduPwrMonitoringOutletCtlPduCEntry .1.3.6.1.4.1.42610.1.4.4.1.6.2.3.4.1 |
outletCtlPduCIndexThe index to outlet control of PduC.ro INTEGER .1.3.6.1.4.1.42610.1.4.4.1.6.2.3.4.1.1 |
outletCtlPduCControlThe control-type of PduC outlet.rw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.6.2.3.4.1.2 |
pduPwrMonitoringOutletPduD OBJECT IDENTIFIER .1.3.6.1.4.1.42610.1.4.4.1.6.2.4 |
pduPwrMonitoringOutletNumPduDThe number of PduD Outlet.ro INTEGER .1.3.6.1.4.1.42610.1.4.4.1.6.2.4.1 |
pduPwrMonitoringOutletStatusTablePduDA list to display status of PduD outlet. SEQUENCE OF PduPwrMonitoringOutletStatusPduDEntry .1.3.6.1.4.1.42610.1.4.4.1.6.2.4.2 |
pduPwrMonitoringOutletStatusPduDEntryA list to display status of PduD outlet. PduPwrMonitoringOutletStatusPduDEntry .1.3.6.1.4.1.42610.1.4.4.1.6.2.4.2.1 |
outletPduDIndexThe index to outlet status of PduD.ro INTEGER .1.3.6.1.4.1.42610.1.4.4.1.6.2.4.2.1.1 |
outletPduDStateThe state of PduD outlet.ro Enumeration .1.3.6.1.4.1.42610.1.4.4.1.6.2.4.2.1.2 |
outletPduDCurrentThe current of PduD outlet.ro INTEGER UNITS "0.01A" .1.3.6.1.4.1.42610.1.4.4.1.6.2.4.2.1.3 |
outletPduDPwrFactorThe power factor of PduD outlet.ro INTEGER UNITS "0.1%" .1.3.6.1.4.1.42610.1.4.4.1.6.2.4.2.1.4 |
outletPduDPowerThe power of PduD outlet.ro INTEGER UNITS "0.1W" .1.3.6.1.4.1.42610.1.4.4.1.6.2.4.2.1.5 |
outletPduDEnergyThe energy of PduD outlet.ro INTEGER UNITS "KWh" .1.3.6.1.4.1.42610.1.4.4.1.6.2.4.2.1.6 |
outletPduDResetFromThe reset date of PduD outlet.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.42610.1.4.4.1.6.2.4.2.1.7 |
outletPduDStatusThe status of PduD outlet.ro Enumeration .1.3.6.1.4.1.42610.1.4.4.1.6.2.4.2.1.8 |
pduPwrMonitoringOutletCfgTablePduDA list to display configuration of PduD outlet. SEQUENCE OF PduPwrMonitoringOutletCfgPduDEntry .1.3.6.1.4.1.42610.1.4.4.1.6.2.4.3 |
pduPwrMonitoringOutletCfgPduDEntryA list to display configuration of PduD outlet. PduPwrMonitoringOutletCfgPduDEntry .1.3.6.1.4.1.42610.1.4.4.1.6.2.4.3.1 |
outletCfgPduDIndexThe index to outlet configuration of PduD.ro INTEGER .1.3.6.1.4.1.42610.1.4.4.1.6.2.4.3.1.1 |
outletCfgPduDNameThe name for outlet of PduD.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.42610.1.4.4.1.6.2.4.3.1.2 |
outletCfgPduDDelayOnStatusThe Delay On status of PduD outlet.rw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.6.2.4.3.1.3 |
outletCfgPduDDelayOnTimeThe Delay On time of PduD outlet.rw INTEGER UNITS "seconds" .1.3.6.1.4.1.42610.1.4.4.1.6.2.4.3.1.4 |
outletCfgPduDDelayOffStatusThe Delay Off status of PduD outlet.rw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.6.2.4.3.1.5 |
outletCfgPduDDelayOffTimeThe Delay Off time of PduD outlet.rw INTEGER UNITS "seconds" .1.3.6.1.4.1.42610.1.4.4.1.6.2.4.3.1.6 |
outletCfgPduDRebootThe Delay On reboot duration of PduD outlet.rw INTEGER UNITS "seconds" .1.3.6.1.4.1.42610.1.4.4.1.6.2.4.3.1.7 |
outletCfgPduDOverCurrCriticalThe Critical Threshold of current of PduD outlet.rw INTEGER UNITS "0.1A" .1.3.6.1.4.1.42610.1.4.4.1.6.2.4.3.1.8 |
outletCfgPduDOverCurrWarningThe Warning Threshold of current of PduD outlet.rw INTEGER UNITS "0.1A" .1.3.6.1.4.1.42610.1.4.4.1.6.2.4.3.1.9 |
outletCfgPduDOverPwrCriticalThe Critical Threshold of power of PduD outlet.rw INTEGER UNITS "1W" .1.3.6.1.4.1.42610.1.4.4.1.6.2.4.3.1.10 |
outletCfgPduDOverPwrWarningThe Warning Threshold of power of PduD outlet.rw INTEGER UNITS "1W" .1.3.6.1.4.1.42610.1.4.4.1.6.2.4.3.1.11 |
pduPwrMonitoringOutletCtlTablePduDA list to display control of PduD outlet. SEQUENCE OF PduPwrMonitoringOutletCtlPduDEntry .1.3.6.1.4.1.42610.1.4.4.1.6.2.4.4 |
pduPwrMonitoringOutletCtlPduDEntryA list to display control of PduD outlet. PduPwrMonitoringOutletCtlPduDEntry .1.3.6.1.4.1.42610.1.4.4.1.6.2.4.4.1 |
outletCtlPduDIndexThe index to outlet control of PduD.ro INTEGER .1.3.6.1.4.1.42610.1.4.4.1.6.2.4.4.1.1 |
outletCtlPduDControlThe control-type of PduD outlet.rw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.6.2.4.4.1.2 |
pduEnvMonitoring OBJECT IDENTIFIER .1.3.6.1.4.1.42610.1.4.4.1.7 |
pduEnvMonitoringStatus OBJECT IDENTIFIER .1.3.6.1.4.1.42610.1.4.4.1.7.1 |
pduEnvMonitoringTempThe temperature of EMD.ro INTEGER UNITS "degC" .1.3.6.1.4.1.42610.1.4.4.1.7.1.1 |
pduEnvMonitoringHumiThe humidity of EMD.ro INTEGER UNITS "0.1%" .1.3.6.1.4.1.42610.1.4.4.1.7.1.2 |
pduEnvMonitoringTempAlarmThe temperature status of EMD.ro Enumeration .1.3.6.1.4.1.42610.1.4.4.1.7.1.3 |
pduEnvMonitoringHumiAlarmThe humidity status of EMD.ro Enumeration .1.3.6.1.4.1.42610.1.4.4.1.7.1.4 |
pduEnvMonitoringCfg OBJECT IDENTIFIER .1.3.6.1.4.1.42610.1.4.4.1.7.2 |
pduEnvMonitoringControlEnable/disable the EMD.rw Enumeration .1.3.6.1.4.1.42610.1.4.4.1.7.2.1 |
pduEnvMonitoringTempHighCriticalThe High Critical Threshold of temperature of EMD.rw INTEGER UNITS "degC" .1.3.6.1.4.1.42610.1.4.4.1.7.2.2 |
pduEnvMonitoringTempHighWarningThe High Warning Threshold of temperature of EMD.rw INTEGER UNITS "degC" .1.3.6.1.4.1.42610.1.4.4.1.7.2.3 |
pduEnvMonitoringTempLowCriticalThe Low Critical Threshold of temperature of EMD.rw INTEGER UNITS "degC" .1.3.6.1.4.1.42610.1.4.4.1.7.2.4 |
pduEnvMonitoringTempLowWarningThe Low Warning Threshold of temperature of EMD.rw INTEGER UNITS "degC" .1.3.6.1.4.1.42610.1.4.4.1.7.2.5 |
pduEnvMonitoringTempHystersisThe Hystersis of Temperature of EMD.rw INTEGER UNITS "degC" .1.3.6.1.4.1.42610.1.4.4.1.7.2.6 |
pduEnvMonitoringTempOffsetThe Offset of Temperature of EMD.rw INTEGER UNITS "degC" .1.3.6.1.4.1.42610.1.4.4.1.7.2.7 |
pduEnvMonitoringHumiHighCriticalThe High Crtitcal Threshold of humidity of EMD.rw INTEGER UNITS "0.1%" .1.3.6.1.4.1.42610.1.4.4.1.7.2.8 |
pduEnvMonitoringHumiHighWarningThe High Warning Threshold of humidity of EMD.rw INTEGER UNITS "0.1%" .1.3.6.1.4.1.42610.1.4.4.1.7.2.9 |
pduEnvMonitoringHumiLowCriticalThe Low Crtitcal Threshold of humidity of EMD.rw INTEGER UNITS "0.1%" .1.3.6.1.4.1.42610.1.4.4.1.7.2.10 |
pduEnvMonitoringHumiLowWarningThe Low Warning Threshold of humidity of EMD.rw INTEGER UNITS "0.1%" .1.3.6.1.4.1.42610.1.4.4.1.7.2.11 |
pduEnvMonitoringHumiHystersisThe Hystersis of Humidity of EMD.rw INTEGER UNITS "0.1%" .1.3.6.1.4.1.42610.1.4.4.1.7.2.12 |
pduEnvMonitoringHumiOffsetThe Ofset of Humidity of EMD.rw INTEGER UNITS "0.1%" .1.3.6.1.4.1.42610.1.4.4.1.7.2.13 |
pduTraps OBJECT IDENTIFIER .1.3.6.1.4.1.42610.1.4.4.2 |
pduSystemColdBootInformational: Cold boot. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.1 |
pduSystemWarmBootInformational: Warm boot. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.2 |
pduSystemRestartInformational: System restart. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.3 |
pduResetToDefaultInformational: Parameters reset to default. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.4 |
pduFirmUpgradeInformational: Firmware upgrade. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.5 |
pduSystemLogClearInformational: System log cleared. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.6 |
pduEventlogClearInformational: Event log cleared. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.7 |
pduInletHistoryClearInformational: Inlet history log cleared. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.8 |
pduOutletHistoryClearInformational: Outlet history log cleared. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.9 |
pduSystemTimeChangeUserInformational: Time changed by user. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.10 |
pduSystemTimeChangeNtpInformational: Time synced with NTP server. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.11 |
pduSystemTimeChangeRtcInformational: Time changed by RTC. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.12 |
pduMailTestPassInformational: Test mail pass. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.13 |
pduMailTestFailInformational: Test mail failed. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.14 |
pduMailSentPassInformational: Mail sent successfully. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.15 |
pduMailSentFailInformational: Mail sent failed. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.16 |
pduSystemCfgChangeInformational: Parameter changed. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.17 |
pduSystemParamImportInformational: Import XML configuration. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.18 |
pduInletCommLostInformational: Inlet communication lost. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.19 |
pduInletCommRestoreInformational: Inlet communication restore. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.20 |
pduOutletCommLostInformational: Outlet communication lost. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.21 |
pduOutletCommRestoreInformational: Outlet communication restore TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.22 |
pduOutletOnUserInformational: Outlet turned on by user. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.23 |
pduOutletOnScheduleInformational: Outlet turned on by schedule. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.24 |
pduOutletOffUserInformational: Outlet turned off by user. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.25 |
pduOutletOffScheduleInformational: Outlet turned off by schedule. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.26 |
pduOutletRebootUserInformational: Outlet reboot by user. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.27 |
pduOutletRebootScheduleInformational: Outlet reboot by schedule. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.28 |
pduInletEnergyResetInformational: Inlet energy reset. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.29 |
pduOutletEnergyResetInformational: Outlet energy reset. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.30 |
pduSetUserInformational: Assign outlet to user. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.31 |
pduDeletUserInformational: Delete user. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.32 |
pduUpgradeInletSuccessInformational: Inlet upgrade successfully. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.33 |
pduUpgradeInletFailInformational: Inlet upgrade fail. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.34 |
pduUpgradeOutletSuccessInformational: Outlet upgrade successfully. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.35 |
pduUpgradeOutletFailInformational: Outlet upgrade fail. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.36 |
pduEmdTempHighWarnToNormalInformational: Temperature had returned from high warning to normal. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.101 |
pduEmdTempHighWarnWarning: Temperature was higher than high warning set point. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.102 |
pduEmdTempLowWarnToNormalInformational: Temperature had returned from low warning to normal. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.103 |
pduEmdTempLowWarnWarning: Temperature was lower than low warning set point. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.104 |
pduEmdTempHighCritToWarnInformational: Temperature had returned from high critical to high warning. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.105 |
pduEmdTempHighCriticalCritical: Temperature was higher than high critical set point. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.106 |
pduEmdTempLowCritToWarnInformational: Temperature had returned from low critical to low warning. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.107 |
pduEmdTempLowCriticalCritical: Temperature was lower than low critical set point. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.108 |
pduEmdHumiHighWarnToNormalInformational: Humidity had returned from high warning to normal. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.109 |
pduEmdHumiHighWarnWarning: Humidity was higher than high warning set point. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.110 |
pduEmdHumiLowWarnToNormalInformational: Humidity had returned from low warning to normal. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.111 |
pduEmdHumiLowWarnWarning: Humidity was lower than low warning set point. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.112 |
pduEmdHumiHighCritToWarnInformational: Humidity had returned from high critical to high warning. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.113 |
pduEmdHumiHighCriticalCritical: Humidity was higher than high critical set point. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.114 |
pduEmdHumiLowCritToWarnInformational: Humidity had returned from low critical to low warning. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.115 |
pduEmdHumiLowCriticalCritical: Humidity was lower than low critical set point. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.116 |
pduEmdAlarm1NotActiveInformational: Alarm-1 became inactive. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.117 |
pduEmdAlarm1ActiveWarning: Alarm-1 became active. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.118 |
pduEmdAlarm2NotActiveInformational: Alarm-2 became inactive. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.119 |
pduEmdAlarm2ActiveWarning: Alarm-2 became active. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.120 |
pduRs485OnlineInformational: RS485 Sensor was online. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.121 |
pduRs485OfflineWarning: RS485 Sensor was offline. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.122 |
pduInletLoadCritToWarnInformational: Inlet load had returned from critical to warning. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.123 |
pduInletLoadCriticalCritical: Inlet load was higher than critical set point. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.124 |
pduInletLoadWarnToNormalInformational: Inlet load had returned from warning to normal. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.125 |
pduInletLoadWarnWarning: Inlet load was higher than warning set point. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.126 |
pduInletCurrPhase1CritToWarnInformational: Inlet phase1 current had returned from critical to warning. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.127 |
pduInletCurrPhase1CriticalCritical: Inlet phase1 current was higher than critical set point. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.128 |
pduInletCurrPhase1WarnToNormalInformational: Inlet phase1 current had returned from warning to normal. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.129 |
pduInletCurrPhase1WarnWarning: Inlet phase1 current was higher than warning set point. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.130 |
pduInletCurrPhase2CritToWarnInformational: Inlet phase2 current had returned from critical to warning. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.131 |
pduInletCurrPhase2CriticalCritical: Inlet phase2 current was higher than critical set point. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.132 |
pduInletCurrPhase2WarnToNormalInformational: Inlet phase2 current had returned from warning to normal. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.133 |
pduInletCurrPhase2WarnWarning: Inlet phase2 current was higher than warning set point. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.134 |
pduInletCurrPhase3CritToWarnInformational: Inlet phase3 current had returned from critical to warning. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.135 |
pduInletCurrPhase3CriticalCritical: Inlet phase3 current was higher than critical set point. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.136 |
pduInletCurrPhase3WarnToNormalInformational: Inlet phase3 current had returned from warning to normal. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.137 |
pduInletCurrPhase3WarnWarning: Inlet phase3 current had returned from critical to warning. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.138 |
pduInletVoltPhase1CritToWarnInformational: Inlet phase1 voltage had returned from critical to warning. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.139 |
pduInletVoltPhase1CriticalCritical: Inlet phase1 voltage was higher than critical set point. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.140 |
pduInletVoltPhase1WarnToNormalInformational: Inlet phase1 voltage had returned from warning to normal. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.141 |
pduInletVoltPhase1WarnWarning: Inlet phase1 voltage was higher than warning set point. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.142 |
pduInletVoltPhase2CritToWarnInformational: Inlet phase2 voltage had returned from critical to warning. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.143 |
pduInletVoltPhase2CriticalCritical: Inlet phase2 voltage was higher than critical set point. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.144 |
pduInletVoltPhase2WarnToNormalInformational: Inlet phase2 voltage had returned from warning to normal. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.145 |
pduInletVoltPhase2WarnWarning: Inlet phase2 voltage was higher than warning set point. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.146 |
pduInletVoltPhase3CritToWarnInformational: Inlet phase3 voltage had returned from critical to warning. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.147 |
pduInletVoltPhase3CriticalCritical: Inlet phase3 voltage was higher than critical set point. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.148 |
pduInletVoltPhase3WarnToNormalInformational: Inlet phase3 voltage had returned from warning to normal. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.149 |
pduInletVoltPhase3WarnWarning: Inlet phase3 voltage was higher than warning set point. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.150 |
pduOutletCurrCritToWarnInformational: Outlet current had returned from critical to warning. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.151 |
pduOutletCurrCriticalCritical: Outlet current was higher than critical set point. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.152 |
pduOutletCurrWarnToNormalInformational: Outlet current had returned from warning to normal. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.153 |
pduOutletCurrWarnWarning: Outlet current was higher than warning set point. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.154 |
pduOutletPwrCritTOWarnInformational: Outlet power had returned from critical to warning. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.155 |
pduOutletPwrCriticalCritical: Outlet power was higher than critical set point. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.156 |
pduOutletPwrWarnToNormalInformational: Outlet power had returned from warning to normal. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.157 |
pduOutletPwrWarnWarning: Outlet power was higher than warning set point. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.158 |
pduAlarm1DisabledInformational: Alarm-1 became disabled. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.159 |
pduAlarm2DisabledInformational: Alarm-2 became disabled. TRAP-TYPE .1.3.6.1.4.1.42610.1.4.4.2.0.160 |