SPP-OPT-MIB

Detailed view of the defined objects, syntax rules, and hierarchical paths.

97
Objects
Active
Status
2
Dependencies

Imported Objects

Objects

97 total
Object Name
codex
OBJECT IDENTIFIER
.1.3.6.1.4.1.449
RFC1155-SMI
Unknown
.1.3.6.1.4.1.449
cdxProductSpecific
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2
cdx6500
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1
cdx6500Configuration
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.2
cdx6500CfgProtocolGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.2.1
cdx6500PCTPortProtocolGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.2.1.1
cdx6500PPCTSPPPortTableThis table contains the SPP Port configuration parameters.
SEQUENCE OF Cdx6500PPCTSPPPortEntry
.1.3.6.1.4.1.449.2.1.2.1.1.30
cdx6500PPCTSPPPortEntryEntries in the SPP Port Configuration Table.
Cdx6500PPCTSPPPortEntry
.1.3.6.1.4.1.449.2.1.2.1.1.30.1
cdx6500SPPPCfgPortNumPort Number of this port.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.30.1.1
cdx6500SPPPCfgPortTypePort Type of the port.ro
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.30.1.2
cdx6500SPPPCfgPortSpeedThis is the speed of the port in bits per second. speed300 : 300 bits per second speed600 : 600 bits per second speed1200 : 1200 bits per second speed1800 : 1800 bits per second speed2400 : 2400 bits per second speed4800 : 4800 bits per second speed7200 : 7200 bits per second speed9600 : 9600 bits per second speed19200 : 19200 bits per second.ro
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.30.1.3
cdx6500SPPPCfgInterchTimeoutThis indicates the maximum time period allowed between received characters. time50 : maximum time period allowed 50 seconds. time100 : maximum time period allowed 100 seconds. time150 : maximum time period allowed 150 seconds. time200 : maximum time period allowed 200 seconds. time250 : maximum time period allowed 250 seconds.ro
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.30.1.4
cdx6500SPPPCfgSLCNumThis specifies the SLC (Smart Line Controller) the port is connected to.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.30.1.5
cdx6500SPPPCfgSLCLineNumThis specifies the line on the SLC (Smart Line Controller) the port is connected to.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.30.1.6
cdx6500SPPPCfgStnIDListList of station identifiers the port will support. A range of station numbers can be entered, for example : 1, 6, 8-12, 250-255 indicates 1, 6, 8, 9, 10, 11, 12, 250, 251, 252, 253, 254, 255 .ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.2.1.1.30.1.7
cdx6500SPPPCfgProtocolIDThe Protocol Identifier is the first four bytes of the call user data. The default is: 0x11, 0x9F, 0xA7, 0x46.ro
DisplayString
.1.3.6.1.4.1.449.2.1.2.1.1.30.1.8
cdx6500SPPPCfgQueueSizeThis specifies the size of the queue which will be used to store the packets to be forwarded to SLC (Smart Line Controller).ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.30.1.9
cdx6500SPPPCfgBlockingThreshThis specifies the blocking threshold for the queue being used by the SPP.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.30.1.10
cdx6500SPPPCfgUnblockThreshThis specifies the unblocking threshold for the queue being used by the SPP.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.1.30.1.11
cdx6500SPPPCfgElectricalInterfaceTypeSpecify the Electrical Interface Type: V.24 - V.24 Electrical Interface Type V.35 - V.35 Electrical Interface Type V.36 - V.36 Electrical Interface Type X.21 - X.21 Electrical Interface Type NONE - Electrically disabledro
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.30.1.12
cdx6500SPPPCfgV24ElectricalInterfaceOptionSpecify the Pin 22 option: RI - V.24 uses Pin 22 for Ring Indicator output signal TM - V.24 uses Pin 22 for Test Mode input signalro
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.30.1.13
cdx6500SPPPCfgHighSpeedElectricalInterfaceOptionSpecify the cable type: NONE - V.35/V.36/X.21 DCE with straight through cable XOVER - V.35/V.36/X.21 DCE with crossover adapter cablero
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.1.30.1.14
cdx6500PCTStationProtocolGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.2.1.3
cdx6500Statistics
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.3
cdx6500StatProtocolGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.3.1
cdx6500PSTPortProtocolGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.3.1.1
cdx6500PPSTSPPPStatsTableThis table contains the SPP Port Statistics Parameters.
SEQUENCE OF Cdx6500PPSTSPPPStatEntry
.1.3.6.1.4.1.449.2.1.3.1.1.31
cdx6500PPSTSPPPStatEntryEntries in the SPP Port Statistics Table.
Cdx6500PPSTSPPPStatEntry
.1.3.6.1.4.1.449.2.1.3.1.1.31.1
cdx6500SPPPStatPortNumPort Number of this port.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.31.1.1
cdx6500SPPPStatPortStatusThis indicates the operational status of the port. disabled : port is disabled enabled : port is enabled busyOut : busy out the port up : port is up down : port is down. newvalDisabled : same functionality as 'disabled', new enumeration added for RFC1155 compatibility.ro
Enumeration
.1.3.6.1.4.1.449.2.1.3.1.1.31.1.2
cdx6500SPPPStatPortTypeThis indicates the type of access protocol for this port.ro
Enumeration
.1.3.6.1.4.1.449.2.1.3.1.1.31.1.3
cdx6500SPPPStatPortSpeedThis indicates the port speed in bits per second. speed300 : 300 bits per second speed600 : 600 bits per second speed1200 : 1200 bits per second speed1800 : 1800 bits per second speed2400 : 2400 bits per second speed4800 : 4800 bits per second speed7200 : 7200 bits per second speed9600 : 9600 bits per second speed19200 : 19200 bits per second.ro
Enumeration
.1.3.6.1.4.1.449.2.1.3.1.1.31.1.4
cdx6500SPPPStatPortUtilInThis indicates the port utilization for the line to port direction.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.31.1.5
cdx6500SPPPStatPortUtilOutThis indicates the port utilization for the port to line direction.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.31.1.6
cdx6500SPPPStatSLCNumThis indicates the number of the SLC to which the port is connected.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.31.1.7
cdx6500SPPPStatSLCLineNumThis indicates the line number of the SLC to which the port is connected.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.31.1.8
cdx6500SPPPStatFlowCntrlStateThis indicates whether the port is blocked by SLC or not.ro
Enumeration
.1.3.6.1.4.1.449.2.1.3.1.1.31.1.9
cdx6500SPPPStatLastStatsResetThis specifies the time stamp of the last statistics reset.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.3.1.1.31.1.10
cdx6500SPPPStatChrsInThis indicates the number of characters that have been received by the port.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.1.31.1.11
cdx6500SPPPStatChrsOutThis indicates the number of characters that have been transmitted by the port.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.1.31.1.12
cdx6500SPPPStatFramesInThis indicates the number of frames that have been received by the port.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.1.31.1.13
cdx6500SPPPStatFramesOutThis indicates the number of frames that have been transmitted by the port.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.1.31.1.14
cdx6500SPPPStatChrsInPerSecThis indicates the rate at which characters have been received by the port.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.31.1.15
cdx6500SPPPStatChrsOutPerSecThis indicates the rate at which characters have been transmitted by the port.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.31.1.16
cdx6500SPPPStatFramesInPerSecThis indicates the rate at which frames have been received by the port.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.31.1.17
cdx6500SPPPStatFramesOutPerSecThis indicates the rate at which frames have been transmitted by the port.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.31.1.18
cdx6500SPPPStatNoOfErrorFramesThis indicates the number of erroneous frames received by the port.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.31.1.19
cdx6500SPPPStatNoOfStnsThis indicates the number of stations on this SLC line.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.31.1.20
cdx6500PSTStationProtocolGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.3.1.3
cdx6500SPSTSPPStnStatTableThis table contains SPP Station statistics parameters.
SEQUENCE OF Cdx6500SPSTSPPSStatEntry
.1.3.6.1.4.1.449.2.1.3.1.3.9
cdx6500SPSTSPPSStatEntryEntries in the SPP Station Statistics Table.
Cdx6500SPSTSPPSStatEntry
.1.3.6.1.4.1.449.2.1.3.1.3.9.1
cdx6500SPPSStatPortNumPort Number of this port.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.9.1.1
cdx6500SPPSStatStnIdThis specifies the entry number of this station.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.9.1.2
cdx6500SPPSStatStnStatusThis indicates the state of the station. disabled : Station is disabled enabled : Station is enabled busyOut : busy out the station up : Station is enabled down : Station is down. newvalDisabled : same functionality as 'disabled', new enumeration added for RFC1155 compatibility.ro
Enumeration
.1.3.6.1.4.1.449.2.1.3.1.3.9.1.3
cdx6500SPPSStatSLCNumThis indicates the number of the SLC to which the port is connected.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.9.1.4
cdx6500SPPSStatSLCLineNumThis indicates the line number of the SLC to which the port is connected.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.9.1.5
cdx6500SPPSStatAdjChanStateThis indicates whether the port is blocked by the adjacent channel or not.ro
Enumeration
.1.3.6.1.4.1.449.2.1.3.1.3.9.1.6
cdx6500SPPSStatCurrCallSummStatusThis indicates the current status of the SPP station. calling : when it is awaiting call accept from Host connected : when the connection to the Host has been established.ro
Enumeration
.1.3.6.1.4.1.449.2.1.3.1.3.9.1.7
cdx6500SPPSStatLastClrCauseCodeThis indicates the cause code received in the last clear packet.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.3.1.3.9.1.8
cdx6500SPPSStatLastClrDiagCodeThis indicates the diagnostic code received in the last clear packet.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.3.1.3.9.1.9
cdx6500SPPSStatLastInCalledAddressThis indicates the called address in the last inbound call packet.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.3.1.3.9.1.10
cdx6500SPPSStatLastInCallingAddressThis indicates the calling address in the last inbound call packet.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.3.1.3.9.1.11
cdx6500SPPSStatLastInCallFacilitiesThis indicates the facilities in the last inbound call request packet.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.3.1.3.9.1.12
cdx6500SPPSStatLastInCallCUDThis indicates the data in the Call User Data field in the last inbound call request packet.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.3.1.3.9.1.13
cdx6500SPPSStatLastOutCalledAddressThis indicates the called address in the last outbound call packet.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.3.1.3.9.1.14
cdx6500SPPSStatLastOutCallingAddressThis indicates the calling address in the last outbound call packet.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.3.1.3.9.1.15
cdx6500SPPSStatLastOutCallFacilitiesThis indicates the facilities in the last outbound call request packet.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.3.1.3.9.1.16
cdx6500SPPSStatLastOutCallCUDThis indicates the data in the Call User Data field in the last outbound call request packet.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.3.1.3.9.1.17
cdx6500SPPSStatChrsInThis indicates the number of characters received by the PAD from SLC for this station.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.9.1.18
cdx6500SPPSStatChrsOutThis indicates the number of characters sent by the PAD to SLC for this station.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.9.1.19
cdx6500SPPSStatFramesInThis indicates the number of frames received by the PAD from SLC for this station.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.9.1.20
cdx6500SPPSStatFramesOutThis indicates the number of frames sent by the PAD to SLC for this station.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.9.1.21
cdx6500SPPSStatChrsInPerSecThis indicates the rate at which characters were received by the PAD from SLC for this station.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.9.1.22
cdx6500SPPSStatChrsOutPerSecThis indicates the rate at which characters were sent by the PAD to SLC for this station.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.9.1.23
cdx6500SPPSStatFramesInPerSecThis indicates the rate at which frames were received by the PAD from SLC for this station.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.9.1.24
cdx6500SPPSStatFramesOutPerSecThis indicates the rate at which frames were sent by the PAD to SLC for this station.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.9.1.25
cdx6500SPPSStatNoOfErrorFramesThis indicates the number of erroneous frames received.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.9.1.26
cdx6500SPPSStatStnStateThis indicates the current status of the configured station. up : station is up dsbl : station is disabled.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.3.1.3.9.1.27
cdx6500SPPSStatLastStatsResetThis specifies the time stamp of the last statistics reset.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.3.1.3.9.1.28
cdx6500Controls
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.4
cdx6500ContSPPTable
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.4.13
cdx6500ContSPPPortTableThis table contains the SPP Port Control parameters.
SEQUENCE OF Cdx6500ContSPPPortEntry
.1.3.6.1.4.1.449.2.1.4.13.1
cdx6500ContSPPPortEntryEntries in the SPP Port Control Table.
Cdx6500ContSPPPortEntry
.1.3.6.1.4.1.449.2.1.4.13.1.1
cdx6500ContSPPPortNumPort Number of this port.
INTEGER
.1.3.6.1.4.1.449.2.1.4.13.1.1.1
cdx6500ContSPPPortBootBoots the specified SPP Port boot : Boot the port.rw
Enumeration
.1.3.6.1.4.1.449.2.1.4.13.1.1.2
cdx6500ContSPPPortEnableEnables the specified SPP Port. enable : Enable the Port.rw
Enumeration
.1.3.6.1.4.1.449.2.1.4.13.1.1.3
cdx6500ContSPPPortDisableDisables the specified SPP Port. disable : Disable Port.rw
Enumeration
.1.3.6.1.4.1.449.2.1.4.13.1.1.4
cdx6500ContSPPPortResetStatsReset statistics for the specified SPP Port. reset : Reset port statistics.rw
Enumeration
.1.3.6.1.4.1.449.2.1.4.13.1.1.5
cdx6500ContSPPStnTableThis table contains the SPP Station Control parameters.
SEQUENCE OF Cdx6500ContSPPStnEntry
.1.3.6.1.4.1.449.2.1.4.13.2
cdx6500ContSPPStnEntryEntries in the SPP Station Control Table.
Cdx6500ContSPPStnEntry
.1.3.6.1.4.1.449.2.1.4.13.2.1
cdx6500SContSPPPortNumPort Number of this port.
INTEGER
.1.3.6.1.4.1.449.2.1.4.13.2.1.1
cdx6500ContSPPStnIdSPP station number.
INTEGER
.1.3.6.1.4.1.449.2.1.4.13.2.1.2
cdx6500ContSPPStnBootBoots the secified SPP station boot : Boot the station.
Enumeration
.1.3.6.1.4.1.449.2.1.4.13.2.1.3
cdx6500ContSPPStnEnableEnables the specified SPP station. enable : Enable station.rw
Enumeration
.1.3.6.1.4.1.449.2.1.4.13.2.1.4
cdx6500ContSPPStnDisableDisables the specified SPP station. disable : Disable Station.rw
Enumeration
.1.3.6.1.4.1.449.2.1.4.13.2.1.5
cdx6500ContSPPStnResetStatsReset statistics for the specified SPP station. reset : Reset station statistics.rw
Enumeration
.1.3.6.1.4.1.449.2.1.4.13.2.1.6
SPP-OPT-MIB - SNMP MIB Reference | MIBs Explorer