Home/Catalog/CDX-6500-COMMON-MIB

CDX-6500-COMMON-MIB

Detailed view of the defined objects, syntax rules, and hierarchical paths.

350
Objects
Active
Status
2
Dependencies

Imported Objects

Objects

350 total
Object Name
codex
OBJECT IDENTIFIER
.1.3.6.1.4.1.449
RFC1155-SMI
Unknown
.1.3.6.1.4.1.449
cdxProductSpecific
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2
cdx6500
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1
cdx6500NodeMgmt
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.1
cdx6500NMSNMPGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.1.1
cdx6500SNMPPrimUDPChanThe primary UDP port used by the SNMP Agent has a default value of 161.rw
DisplayString
.1.3.6.1.4.1.449.2.1.1.1.1
cdx6500SNMPSecUDPChanThe secondary UDP port used by the SNMP Agent has a default value of 162.rw
DisplayString
.1.3.6.1.4.1.449.2.1.1.1.2
cdx6500SNMPAgentTimerAn internal timer used by the SNMP agent, unit is a 20 ms tick.rw
INTEGER
.1.3.6.1.4.1.449.2.1.1.1.3
cdx6500SNMPTrapEnableA control object to disable or enable the SNMP agent's trap send capability. newvalDisable : same functionality as 'disable', new enumeration added for RFC1155 compatibility.rw
Enumeration
.1.3.6.1.4.1.449.2.1.1.1.4
cdx6500SNMPBootAgentA control object. Setting to value `boot' will cause the SNMP agent to boot.rw
Enumeration
.1.3.6.1.4.1.449.2.1.1.1.5
cdx6500SNMPResetStatsA control object, which when set to value `reset', will cause the SNMP agent to reset all its statistics.rw
Enumeration
.1.3.6.1.4.1.449.2.1.1.1.6
cdx6500SNMPLastTrapThe interesting information portion of the last trap PDU issued by the SNMP Agent.ro
DisplayString
.1.3.6.1.4.1.449.2.1.1.1.7
cdx6500SNMPGenTrapsTypeChoice between generic traps as defined in RFC or correponding enterprise specific traps to be generated by the node. This attribute is applicable only when generic traps are being generated and there exists a corresponding enterprise specific trap.rw
Enumeration
.1.3.6.1.4.1.449.2.1.1.1.8
cdx6500SNMPTrapThrottleTableThrottling table.
SEQUENCE OF Cdx6500SNMPTrapThrottleEntry
.1.3.6.1.4.1.449.2.1.1.1.9
cdx6500SNMPTrapThrottleEntryEntry representing throttling parameters.
Cdx6500SNMPTrapThrottleEntry
.1.3.6.1.4.1.449.2.1.1.1.9.1
cdx6500SNMPTrapNumberTrap number to be throttled.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.1.9.1.1
cdx6500SNMPMaxNumOfTrapsNumber of traps allowed to be generated in the throttling period.rw
INTEGER
.1.3.6.1.4.1.449.2.1.1.1.9.1.2
cdx6500SNMPThrottlingPeriodThrottling time period in seconds. Value 0 means trap is not throttled.rw
INTEGER
.1.3.6.1.4.1.449.2.1.1.1.9.1.3
cdx6500SNMPNewTrapLevelNew severity level for the trap.rw
Enumeration
.1.3.6.1.4.1.449.2.1.1.1.9.1.4
cdx6500SNMPEntryStatusTable row status. Setting the value to deleted removes the entry from the table.rw
Enumeration
.1.3.6.1.4.1.449.2.1.1.1.9.1.5
cdx6500SNMPSetControlSnmp Set operation control off : snmp set operation is not allowed on : snmp set operation is allowed.ro
Enumeration
.1.3.6.1.4.1.449.2.1.1.1.10
cdx6500SNMPIpAddressIP address for this node.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.1.1.11
cdx6500NMNodeParametersGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.1.2
cdx6500NMNPconfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.1.2.1
cdx6500NMNPCnodeNameThis parameter identifies the node with a name, which appears at the top of control terminal menus and reports. Range is 0 to 8 alphanumeric characters.ro
DisplayString
.1.3.6.1.4.1.449.2.1.1.2.1.1
cdx6500NMNPCnodeNumThe node number identifies the node for X.25 routing purposes to prevent routing loops.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.1.2
cdx6500NMNPCnodeAddressThe node address specifies the main part of the network address for calls destined within this node: PAD port or node resource (for example, control port) calls. Individual subaddresses specify exact destination.ro
DisplayString
.1.3.6.1.4.1.449.2.1.1.2.1.3
cdx6500NMNPCchassisThis parameters identifies the type of chassis that this node is residing in. This is necessary in order to correctly interpret the fan and power supply status signals. newvalStandalone : same functionality as 'standalone', new enumeration added for RFC1155 compatibility.ro
Enumeration
.1.3.6.1.4.1.449.2.1.1.2.1.4
cdx6500NMNPCdateThe node date used for date stamps of events and traps. The format of the string is yyyymmmdd, year: four digits, month: first three letters of the month, day: 01..31.ro
DisplayString
.1.3.6.1.4.1.449.2.1.1.2.1.5
cdx6500NMNPCtimeThe node time used for time stamps of events and traps. The format of the string is hhmmss, hour: 00..23, minute 00..59, second: 00..59.ro
DisplayString
.1.3.6.1.4.1.449.2.1.1.2.1.6
cdx6500NMNPCportUtilPort Utilization Threshold (%). This parameter sets the alarm level for traffic on every port in a node. The traffic is checked over a 64-second interval to give an average (in characters per second). This is compared to the port's clock rate and a utilization factor is produced. If the percent of utiliaztion exceeds the setting, an alarm is generated. Port utilization records are kept for each port and the port in question is noted in the report.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.1.7
cdx6500NMNPCbuffUtilBuffer Utilization Threshold (%). This parameter sets the alarm level for data buffers. When data passes through a node, buffers provide temporary storage. If the number of buffers used exceeds the specified percentage of available storage, an alarm is generated.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.1.8
cdx6500NMNPCcpuUtilCPU Utilization Threshold (%). If the CPU is not processing data, it is running diagnostic checks. It is never idle. This parameter specifies the amount of time spent performing non-diagnostic functions as a percentage of the total time. If this percentage exceeds the threshold, an alarm is generated.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.1.9
cdx6500NMNPCportErrPort Error Threshold. This threshold specifies the number of port errors (such as parity or framing errors) that can be detected before a medium severity alarm is generated. For example, if this parameter is set to 10, an alarm is sent when 10 errors are detected, another alarm is sent when the 20th error is detected, etc.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.1.10
cdx6500NMNPCalarmTmrAlarm Threshold Timer. This parameter prevents a node from sending threshold alarms too frequently. If a node generates an alarm the threshold alarm timer is started and the node is not allowed to generate the same alarm until the timer has expired. This controls the frequency of alarm reporting.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.1.11
cdx6500NMNPCmaxRoutHopsMaximum Routing Hops.This parameter specifies the maximum number of nodes a call may pass through before reaching its destination.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.1.12
cdx6500NMNPCctpSubAddrThis parameter specifies the Control Port (CTP) Subaddress. Calls with network address composed of the node address and this subaddress will be routed to the control port in this node. No routing table entry is needed.ro
DisplayString
.1.3.6.1.4.1.449.2.1.1.2.1.13
cdx6500NMNPCctpIdleTimeControl Port Idle Disconnect Time (minutes). This specifies how many minutes of inactivity can occur before the control terminal is automatically disconnectedro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.1.14
cdx6500NMNPCalmDistThis object has been replaced by cdx6500NMNPCalmDistrib.rodeprecated
Enumeration
.1.3.6.1.4.1.449.2.1.1.2.1.15
cdx6500NMNPCalmMmemAlarm Printer Mnemonic. This specifies the mnemonic name for the destination of alarms sent by the node (if Alarm Distribution = PRIN). This destination is usually a printer or a personal computer. To prevent any alarms from being sent, set this to blank.ro
DisplayString
.1.3.6.1.4.1.449.2.1.1.2.1.16
cdx6500NMNPCalmSelectThis object has been replaced by cdx6500NMNPCalmSelection.rodeprecated
Enumeration
.1.3.6.1.4.1.449.2.1.1.2.1.17
cdx6500NMNPCbroadPortSubadThis specifies the broadcast port subaddress for this node. Calls with network address composed of the node address and this subaddress will be routed to the broadcast port in this node. No routing table entry is needed.ro
DisplayString
.1.3.6.1.4.1.449.2.1.1.2.1.18
cdx6500NMNPCnoBroadNetsNumber of Broadcast Nets. This specifies the number of Broadcast Networks to which this node can send broadcast messages. A value of 0 will disable broadcast functions.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.1.19
cdx6500NMNPCnoBroadInChNumber of Broadcast Input Channels. This specifies the number of simultaneous broadcast messages that can be received.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.1.20
cdx6500NMNPCbillMnemWhen billing records need to be printed, the node will use this mnemonic to call and send the records to this destination. This location is usually a printer used to print billing records.ro
DisplayString
.1.3.6.1.4.1.449.2.1.1.2.1.21
cdx6500NMNPCbillThreshWhen the number of billing records queued up equals this threshold, a call will be placed to the logging device to dump the billing records.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.1.22
cdx6500NMNPCmaxBillThis is the maximum number of billing records the node will be allowed to store to be printed. Billing records created after this maximum is reached will be lost.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.1.23
cdx6500NMNPCbillTimerIf billing records have been stored for printing for this amount of time (in minutes) without reaching the threshold, a call will be made so that they can be printed.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.1.24
cdx6500NMNPCpvcBillAt this interval the billing records will be gathered and printed for all of the PVC's in the node that have billing turned on.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.1.25
cdx6500NMNPCmaxCallsLimiting the number of calls allowed in the node will eliminate data loss in extreme traffic conditions.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.1.26
cdx6500NMNPCpadBulletinPAD Bulletin Message. Specifies the message that appears when a terminal connects to PAD port and enters Command Mode. To have no message appear, select blank.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.1.2.1.27
cdx6500NMNPCpadBannerPAD Banner Message. Specifies the message PAD ports send to attached terminals when they enter Command Mode. These special characters can be used to display certain information in the PAD Banner Message. A Node address C Channel Number G Group sub-address N Node Name P Port Number S Sub-address T Time V Software revision If the character following the % symbol is not one of the above, both the % and following character are discarded. The caret (^) is used as an escape character to tell the PAD to send control characters. The character following the caret is converted to a control character and is sent to the PAD port for output. The caret is discarded unless it is entered twice (^^).ro
DisplayString
.1.3.6.1.4.1.449.2.1.1.2.1.28
cdx6500NMNPCdcpFacThis defines the facility used to carry DCP information at call setup and reconnection time in Call Request and Call Accept packets through the 6500 network. Change the value only if it interferes with some other private network facility.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.1.29
cdx6500NMNPCtrafficPriTraffic Priority. This is the default traffic priority to be used on the node. newvalLow : same functionality as 'low', new enumeration added for RFC1155 compatibility.ro
Enumeration
.1.3.6.1.4.1.449.2.1.1.2.1.30
cdx6500NMNPCtrafficStepTraffic Priority Step. This specifies the number of packets to be transmitted for each lower priority packet transmitted.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.1.31
cdx6500NMNPCpropProtIdThis is the Codex Proprietary Protocol ID. Its value is put in the first byte of the Protocol Identifier field of the CUD in the Call Request packets for protocols that have not been assigned a standardized value by the CCITT.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.1.32
cdx6500NMNPClanSubAddrCalls with network address composed of the node address and this subaddress will be routed to a LAN Connection in this node.ro
DisplayString
.1.3.6.1.4.1.449.2.1.1.2.1.33
cdx6500NMNPCMaxFrameSizeThe largest datalink level frame that will ever be received on any link. On WAN links this does not include space that is reserved internally for trailers.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.1.34
cdx6500NMNPCCodexGroupFacilityThis is the facility used in call packets on Codex 6500 links for passing CODEX PRIVATE facilities other than Hop Count and DCP facilities between 4.xx nodes. This should be the SAME on all nodes in the network. It need only be changed if it interferes with some other private network facility.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.1.35
cdx6500NMNPCalmDistribDistribution of alarms is controlled by specifying: NONE - no alarm is sent\r\n\ CTP - send alarms to Control Port Terminal\r\n\ PRIN - send alarms to Printer Destination\r\n\ Any combination of above specified by summing (e.g. CTP+PRIN).ro
DisplayString
.1.3.6.1.4.1.449.2.1.1.2.1.36
cdx6500NMNPCalmSelectionAlarm type reporting by the node: NONE - no alarms reported. HIGH - high severity alarms reported. MED - medium severity alarms reported. LOW - low severity alarms reported. CONN - connection events reported. CODE - alarms from Codex 6000 communication processors reported. Any combination of above specified by summing (e.g. HIGH+CONN+. . .).ro
DisplayString
.1.3.6.1.4.1.449.2.1.1.2.1.37
cdx6500NMNPChopFacilityHop Count Facility. This is the facility used in call packets on X.25 links with the INL option for network routing. This should be the SAME in all nodes in the network. It need only be changed if it interferes with some other private network facility.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.1.38
cdx6500NMNPCnumNccpDevicesThis is the number of NCCP devices.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.1.39
cdx6500NMNPCmaxCallidThis is the maximum number of Call id numbers that go in the Calling Identifier table. This table can have a maximum of 512 entries. Each entry of 30 digits.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.1.40
cdx6500NMNPinvent
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.1.2.2
cdx6500NMNPIproductTypeIdentifies a general class of feature set for the product, e.g. 6504PLUS Asynchronous PAD or 6520 Branch Nodero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.1.2.2.1
cdx6500NMNPIsoftwareSrcThe source of software currently running on the node. prom - CPU running from code in PROM. download - CPU downloading code into RAM. promLoadingRAM - CPU running from code in RAM. newvalProm - same functionality as 'prom', new enumeration added for RFC1155 compatibility.ro
Enumeration
.1.3.6.1.4.1.449.2.1.1.2.2.2
cdx6500NMNPIserialNumThe serial number of the motherboard.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.2.3
cdx6500NMNPIpromRevisionThe PROM software revision.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.1.2.2.4
cdx6500NMNPIdlCodeRevisionThe downloaded software revision. Applicable to 6500 platforms.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.1.2.2.5
cdx6500NMNPIdlCodeSourceThe source of downloaded software. Applicable to 6500 platforms.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.1.2.2.6
cdx6500NMNPIdlCodeSizeThe size of downloaded software in bytes. Applicable to 6500 platforms.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.2.7
cdx6500NMNPIflashStatusThe status of use of flash memory. Applicable only to 6500 platforms. newvalEnabled : same functionality as 'enabled', new enumeration added for RFC1155 compatibility.ro
Enumeration
.1.3.6.1.4.1.449.2.1.1.2.2.8
cdx6500NMNPIflashIdCurName and version of software stored in flash. This refers to the currently selected bank of flash when there is an alternate bank of flash installed.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.1.2.2.9
cdx6500NMNPIflashIdAltName and version of software contained by the alternate bank of flash (if installed). Applicable to 6520 platforms.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.1.2.2.10
cdx6500NMNPIflashSizeCurSize of software stored in flash. This refers to the currently selected bank of flash when there is an alternate bank of flash installed.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.2.11
cdx6500NMNPIflashSizeAltSize of software in the alternate bank of flash (bytes). Applicable to 6520 platforms.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.2.12
cdx6500NMNPIinventTableA list of the node's boards.
SEQUENCE OF Cdx6500NMNPIinventEntry
.1.3.6.1.4.1.449.2.1.1.2.2.13
cdx6500NMNPIinventEntryEach entry contains a board number, board type, number of ports, status, and serial number.
Cdx6500NMNPIinventEntry
.1.3.6.1.4.1.449.2.1.1.2.2.13.1
cdx6500NMNPIinventBoardThe board number. This is used to index the boards in a node.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.2.13.1.1
cdx6500NMNPIinventTypeThe board type. A description of the type of board.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.1.2.2.13.1.2
cdx6500NMNPIinventPortsThe number of I/O ports for this board.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.2.13.1.3
cdx6500NMNPIinventStatusThe status of the boardro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.1.2.2.13.1.4
cdx6500NMNPIinventSerialThe serial number of the boardro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.1.2.2.13.1.5
cdx6500NMNPIinventAssyThe assembly number of the boardro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.1.2.2.13.1.6
cdx6500NMNPIinventRevThe revision level of the boardro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.1.2.2.13.1.7
cdx6500NMNPIinventDIM1The type of interface specified by DIM 1.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.1.2.2.13.1.8
cdx6500NMNPIinventDIM2The type of interface specified by DIM 2.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.1.2.2.13.1.9
cdx6500NMNPIinventPortConfigTableA list of the node's Port Configuration.
SEQUENCE OF Cdx6500NMNPIinventPortConfigEntry
.1.3.6.1.4.1.449.2.1.1.2.2.14
cdx6500NMNPIinventPortConfigEntryEach entry contains a port configuration.
Cdx6500NMNPIinventPortConfigEntry
.1.3.6.1.4.1.449.2.1.1.2.2.14.1
cdx6500NMNPIinventPortNumThe port number. This is used to index the ports in a node.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.2.14.1.1
cdx6500NMNPIinventPortConfigThe port configuration on each board.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.1.2.2.14.1.2
cdx6500NMNPstats
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.1.2.3
cdx6500NMNPSevLastOccPowerThe last time the node was turned on.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.1.2.3.1
cdx6500NMNPSevLastOccResetThe last time the reset button was pressed.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.1.2.3.2
cdx6500NMNPSevLastOccRebootThe last time the node was rebooted.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.1.2.3.3
cdx6500NMNPSevLastOccWDTimerThe last time the watch dog timer expired.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.1.2.3.4
cdx6500NMNPSevLastOccConfigThe last time the configuration memory was changed or downloaded.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.1.2.3.5
cdx6500NMNPSstatusFanThe operational status of the cooling fan. newvalNotMonitored : same functionality as 'notMonitored', new enumeration added for RFC1155 compatibility.ro
Enumeration
.1.3.6.1.4.1.449.2.1.1.2.3.6
cdx6500NMNPSstatusPwrSyThe operational status of the power supply. This object is being replaced by cdx6500NMNPSstatusPowerSy. newvalNotMonitored : same functionality as 'notMonitored', new enumeration added for RFC1155 compatibility.rodeprecated
Enumeration
.1.3.6.1.4.1.449.2.1.1.2.3.7
cdx6500NMNPScmemSizeCompSize of compressed configuration memory available (free) in bytes.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.3.8
cdx6500NMNPScmemUseCompSize of compressed configuration memory in use in bytes.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.3.9
cdx6500NMNPScmemSizeUncompSize of uncompressed configuration memory available (free) in bytes.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.3.10
cdx6500NMNPScmemUseUnCompSize of uncompressed configuration memory in use in bytes.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.3.11
cdx6500NMNPScallsInPlaceCurNumber of X.25 calls. The number of calls currently in place.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.3.12
cdx6500NMNPScallsInPlaceMaxNumber of X.25 calls gauge. The maximum number of calls since the last reset.ro
Gauge
.1.3.6.1.4.1.449.2.1.1.2.3.13
cdx6500NMNPScallsPerSecCurRate of X.25 calls. The number of calls/sec. currently in place.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.3.14
cdx6500NMNPScallsPerSecMaxRate of X.25 calls gauge. The maximum number of calls/sec. since the last reset.ro
Gauge
.1.3.6.1.4.1.449.2.1.1.2.3.15
cdx6500NMNPSpvcConnectCurPermanent virtual circuit connections. The number currently in place.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.3.16
cdx6500NMNPSPVCConnectMaxPermanent virtual circuit connections. The maximum since the last reset.ro
Gauge
.1.3.6.1.4.1.449.2.1.1.2.3.17
cdx6500NMNPSbuffDataAvailThe number of data buffers available. Applicable to all platforms.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.3.18
cdx6500NMNPSbuffDataUseThe number of data buffers in use. Applicable to all platforms.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.3.19
cdx6500NMNPSbuffDataGaugeThe maximum number of data buffers in use since last reset Applicable to all platforms.ro
Gauge
.1.3.6.1.4.1.449.2.1.1.2.3.20
cdx6500NMNPSbuffPacketAvailThe number of packet buffers available. Applicable to all platforms except VG100 .ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.3.21
cdx6500NMNPSbuffPacketUseThe number of packet buffers in use. Applicable to all platforms except VG100.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.3.22
cdx6500NMNPSbuffPacketExhaustThe number of times the packet buffer pool has been exhausted since last reset. Applicable to all platforms except VG100.ro
Gauge
.1.3.6.1.4.1.449.2.1.1.2.3.23
cdx6500NMNPSbuffMgtAvailThe number of management buffers available. Applicable to all platforms except VG100.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.3.24
cdx6500NMNPSbuffMgtUseThe number of management buffers in use. Applicable to all platforms except VG100.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.3.25
cdx6500NMNPSbuffMgtExhaustThe number of times the management buffer pool has been exhausted since last reset. Applicable to all platforms except VG100.ro
Gauge
.1.3.6.1.4.1.449.2.1.1.2.3.26
cdx6500NMNPSrateCurCharNode throughput, number of current chararacters/second for the node.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.3.27
cdx6500NMNPSrateCurPktNode throughput, number of current packets/second for the node.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.3.28
cdx6500NMNPSrateMaxCharNode throughput gauge, Number of maximum characters/second for the node since last resetro
Gauge
.1.3.6.1.4.1.449.2.1.1.2.3.29
cdx6500NMNPSrateMaxPktNode throughput gauge, Number of maximum packets/second for the node since last resetro
Gauge
.1.3.6.1.4.1.449.2.1.1.2.3.30
cdx6500NMNPSmemEpromAmount of memory available on the processor card in bytes. Applicable to 6520 platforms.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.3.31
cdx6500NMNPSmemDramAmount of memory used for data buffers in bytes. Applicable to 6520 platforms.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.3.32
cdx6500NMNPSmemFlashCurThe size of the flash module in bytes. This refers to the currently selected bank of flash when there is an alternate bank of flash installed. Applicable to 6520 platforms.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.3.33
cdx6500NMNPSmemFlashAltThe size of the alternate flash module in bytes. Applicable to 6520 platforms.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.3.34
cdx6500NMNPScpuUtilPercentage of time the CPU processed traffic data (as opposed performing diagnositic tests or processing node control data) to in the last 64 seconds. Applicable to 6520 platforms.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.3.35
cdx6500NMNPSDisplayNumImageFront panel numeric display. Applicable to 6520 platforms.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.1.2.3.36
cdx6500NMNPSDisplayLEDstatusFront panel status LED. Applicable to 6520 platforms. newvalOff : same functionality as 'off', new enumeration added for RFC1155 compatibility.ro
Enumeration
.1.3.6.1.4.1.449.2.1.1.2.3.37
cdx6500NMNPSDisplayLEDdiagFront panel fault (or service) LED. Applicable to 6520 platforms. newvalOff : same functionality as 'off', new enumeration added for RFC1155 compatibility.ro
Enumeration
.1.3.6.1.4.1.449.2.1.1.2.3.38
cdx6500NMNPSdefaultNodeA control object. Setting to value default will cause the current configuration of the entire node to change back to the default settings. CAUTION: If you implement the Default Node control, communications are disrupted and data could be lost after a boot. In addition, configuration settings are lost unless they had been saved to an external device.
Enumeration
.1.3.6.1.4.1.449.2.1.1.2.3.39
cdx6500NMNPSresetStatTableA list of Port Statistic Reset entries.
SEQUENCE OF Cdx6500NMNPSresetStatEntry
.1.3.6.1.4.1.449.2.1.1.2.3.40
cdx6500NMNPSresetStatEntryEach entry contains a port number and a control to reset statistics for that port.
Cdx6500NMNPSresetStatEntry
.1.3.6.1.4.1.449.2.1.1.2.3.40.1
cdx6500NMNPSresetStatPortThe port number value for this object directs the statistics reset command to that port.
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.3.40.1.1
cdx6500NMNPSresetStatStatusA value of reset will cause a port's statistics to be reset. A value of noReset has no effect.rw
Enumeration
.1.3.6.1.4.1.449.2.1.1.2.3.40.1.2
cdx6500NMNPSresetStatAllA value of reset will cause statistics to be reset on all ports. A value of noReset has no effect.rw
Enumeration
.1.3.6.1.4.1.449.2.1.1.2.3.41
cdx6500NMNPSstatusPowerSyThe operational status of the power supply. This object replaces cdx6500NMNPSstatusPwrSy.ro
DisplayString
.1.3.6.1.4.1.449.2.1.1.2.3.42
cdx6500NMNPSstatsTableBoard specific statistics. Applicable to 6500 platforms.
SEQUENCE OF Cdx6500NMNPSstatsEntry
.1.3.6.1.4.1.449.2.1.1.2.3.43
cdx6500NMNPSstatsEntryA Board statistics Table entry. Each entry contains statistics parameters for a single board. Applicable to 6500 platforms.
Cdx6500NMNPSstatsEntry
.1.3.6.1.4.1.449.2.1.1.2.3.43.1
cdx6500NMNPSstatsBoardBoard number. Applicable to 6500 platforms.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.3.43.1.1
cdx6500NMNPSstatsbuffDataAvailThe number of data buffers available. Applicable to 6500 platforms.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.3.43.1.2
cdx6500NMNPSstatsbuffDataUseThe number of data buffers in use. Applicable to 6500 platforms.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.3.43.1.3
cdx6500NMNPSstatsbuffDataGaugeThe maximum number of data buffers in use since last reset Applicable to 6500 platforms.ro
Gauge
.1.3.6.1.4.1.449.2.1.1.2.3.43.1.4
cdx6500NMNPSstatsmemEpromAmount of memory available on the processor card in bytes. Applicable to 6500 platforms.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.3.43.1.5
cdx6500NMNPSstatsmemDramAmount of memory used for data buffers in bytes. Applicable to 6500 platforms.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.3.43.1.6
cdx6500NMNPSstatsmemFlashThe size of the flash module in bytes. This refers to the currently selected bank of flash when there is an alternate bank of flash installed. Applicable to 6500 platforms.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.3.43.1.7
cdx6500NMNPSstatscpuUtilPercentage of time the CPU processed traffic data (as opposed performing diagnositic tests or processing node control data) to in the last 64 seconds. Applicable to 6500 platforms.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.3.43.1.8
cdx6500NMNPSstatsMaxcpuUtilPeak CPU Utilization since last node or statistics reset. Applicable to 6500 platforms.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.3.43.1.9
cdx6500NMNPSstatsMaxcpuUtilTimeTime stamp of Peak CPU Utilization since last node or statistics reset. Applicable to 6500 platforms.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.1.2.3.43.1.10
cdx6500NMNPScallsInPlaceMaxTimeTime stamp of Max number of calls since the last reset.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.1.2.3.44
cdx6500NMNPSPVCConnectMaxTimeTime stamp of Max number of PVC connections since the last reset.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.1.2.3.45
cdx6500NMNPScallsPerSecMaxTimeTime stamp of Max number of calls/sec since the last reset.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.1.2.3.46
cdx6500NMNPSbuffDataGaugeTimeTime stamp of Max number of data buffers in use since the last reset. Applicable to all platforms.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.1.2.3.47
cdx6500NMNPSbuffPacketGaugeThe maximum number of packet buffers in use since the last reset. Applicable to all platforms except VG100.ro
Gauge
.1.3.6.1.4.1.449.2.1.1.2.3.48
cdx6500NMNPSbuffPacketGaugeTimeTime stamp of Max number of packet buffers in use since the last reset. Applicable to all platforms except VG100.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.1.2.3.49
cdx6500NMNPSbuffMgtGaugeThe maximum number of management buffers in use since the last reset. Applicable to all platforms except VG100.ro
Gauge
.1.3.6.1.4.1.449.2.1.1.2.3.50
cdx6500NMNPSbuffMgtGaugeTimeTime stamp of Max number of management buffers in use since the last reset. Applicable to all platforms except VG100.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.1.2.3.51
cdx6500NMNPSrateMaxCharTimeTime stamp of Max node throughput (chars/sec) since the last reset.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.1.2.3.52
cdx6500NMNPSrateMaxPktTimeTime stamp of Max node throughput (packets/sec) since the last reset.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.1.2.3.53
cdx6500NMNPSMaxcpuUtilPeak CPU Utilization since last node or statistics reset. Applicable to 6520 platforms.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.2.3.54
cdx6500NMNPSMaxcpuUtilTimeTime stamp of Peak CPU Utilization since last node or statistics reset. Applicable to 6520 platforms.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.1.2.3.55
cdx6500NMDiagnosticsGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.1.3
cdx6500NMReportTableAll of the statistics parameters relevant to the Report event log table.
SEQUENCE OF Cdx6500NMReportEntry
.1.3.6.1.4.1.449.2.1.1.3.1
cdx6500NMReportEntryA row of Report Statistics parameters.
Cdx6500NMReportEntry
.1.3.6.1.4.1.449.2.1.1.3.1.1
cdx6500reptIndexReport Log Index
INTEGER
.1.3.6.1.4.1.449.2.1.1.3.1.1.1
cdx6500reptEventReport Log Alarm Textro
DisplayString
.1.3.6.1.4.1.449.2.1.1.3.1.1.2
cdx6500NMreptClearLogClears the Operator log. clearLog - Clear the Log noClearLog - Do not clear the Log.rw
Enumeration
.1.3.6.1.4.1.449.2.1.1.3.2
cdx6500NMV54Loopback
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.1.3.3
cdx6500NMV54LocalLoopLocal loop test; The test will start when set to value 'startTest'.rwobsolete
Enumeration
.1.3.6.1.4.1.449.2.1.1.3.3.1
cdx6500NMV54Loop2Loopback test 2 : Loop at remote modem digital side.rwobsolete
Enumeration
.1.3.6.1.4.1.449.2.1.1.3.3.2
cdx6500NMV54Loop3Loopback test 3: Loop at local modem analog side.rwobsolete
Enumeration
.1.3.6.1.4.1.449.2.1.1.3.3.3
cdx6500NMV54turnLoopbackOffA control to turn any loopback test offrwobsolete
Enumeration
.1.3.6.1.4.1.449.2.1.1.3.3.4
cdx6500NMV54LoopbackDurationDuration of loopback in seconds.rw
INTEGER
.1.3.6.1.4.1.449.2.1.1.3.3.5
cdx6500NMV54TestTypeLoopback test type.roobsolete
Enumeration
.1.3.6.1.4.1.449.2.1.1.3.3.6
cdx6500NMV54LoopbackStatusLoopback Status. v54Starting - test is being prepared to start. v54Running - test in progress. v54Stopping - test is being stopped. v54Clearing - system is clearing resources used for the test. v54Stopped - test has been completed. v54AbortPortDisabled - selected port is disabled. v54AbortIsRunning - test is already running on the specified port. v54AbortPortNull - selected port is of NULL type. v54AbortEiaDisc - interface has been disconnected during the test. v54AbortCpuNotRunning - CPU is not running on the specified port. v54AbortNotSupported - specified test is not supported by the selected port. v54AbortWrongParams - specified test params are incorrect. Check port number. v54AbortWrongPort - specified port is incorrect. v54NotRun - test has not been run yet.ro
Enumeration
.1.3.6.1.4.1.449.2.1.1.3.3.7
cdx6500NMV54MessagesSentNumber of messages sentroobsolete
INTEGER
.1.3.6.1.4.1.449.2.1.1.3.3.9
cdx6500NMV54GoodMsgsReceivedNumber of good messages receivedroobsolete
INTEGER
.1.3.6.1.4.1.449.2.1.1.3.3.10
cdx6500NMV54BadMsgsReceivedNumber of bad messages receivedroobsolete
INTEGER
.1.3.6.1.4.1.449.2.1.1.3.3.11
cdx6500NMV54LastPortTestedLast port to be put in loopback.roobsolete
INTEGER
.1.3.6.1.4.1.449.2.1.1.3.3.12
cdx6500NMV54CurrentTestPortCurrent test port.rwobsolete
INTEGER
.1.3.6.1.4.1.449.2.1.1.3.3.13
cdx6500NMV54LoopbackTestStarts and stops loopback test.rw
Enumeration
.1.3.6.1.4.1.449.2.1.1.3.3.14
cdx6500NMV54LoopbackTestTypeLoopback test type. v54LocalLoop - creates a loop on the selected port. v54Loop2 - creates a loop on the remote modem digital side. v54Loop3 - creates a loop on the local modem analog side. dsuInternal - creates a loop on the internal interface. dsuInternalExternal - creates a loop on the internal and the external interfaces.rw
Enumeration
.1.3.6.1.4.1.449.2.1.1.3.3.15
cdx6500NMV54LoopbackLastPortTestedLast port put in loopback.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.3.3.16
cdx6500NMV54LoopbackCurrentTestPortCurrent test port. Value zero means that no port has been specified. When test completes, this object is defaulted to zero.rw
INTEGER
.1.3.6.1.4.1.449.2.1.1.3.3.17
cdx6500NMV54LoopbackMessagesSentNumber of messages sentro
Counter
.1.3.6.1.4.1.449.2.1.1.3.3.18
cdx6500NMV54LoopbackGoodMsgsReceivedNumber of good messages receivedro
Counter
.1.3.6.1.4.1.449.2.1.1.3.3.19
cdx6500NMV54LoopbackBadMsgsReceivedNumber of bad messages receivedro
Counter
.1.3.6.1.4.1.449.2.1.1.3.3.20
cdx6500NMControlsGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.1.4
cdx6500NMCBootNodeSetting this object will cuase the node to perform either a cold or a warm Node boot : bootCold - perform a cold Node Boot; run diagnostic tests, reload operational software, request software download if neccessary, reload configuration and start the node. bootWarm - perform a warm Node Boot; reload configuration and start the node. newvalBootCold - same functionality as 'bootCold', new enumeration added for RFC1155 compatibility.rw
Enumeration
.1.3.6.1.4.1.449.2.1.1.4.1
cdx6500NMCBootTableNodeRecSetting to bootrec will cause the running configuration to be updated using new configuration tables from CMEM.rw
Enumeration
.1.3.6.1.4.1.449.2.1.1.4.2
cdx6500NMDLSVGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.1.5
cdx6500DLSVDLstateStatistic - state of the download dlStart : Setup phase. dlCall : Setup phase. dlReq : Setup phase. dlLoad : Downloading phase. dlGss : Setup phase. dlLgs : Downloading phase. dlDone : Download Complete. dlBoot : Download Complete. dlIdle : No download.ro
Enumeration
.1.3.6.1.4.1.449.2.1.1.5.1
cdx6500DLSVPercentCompleteStatistic - amount of download that has completed.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.5.2
cdx6500DLSVTimestampStatistic - time of last download.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.1.5.3
cdx6500DLSVLastServerStatistic - Last server node to send software.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.1.5.4
cdx6500DLSVTransferTypeStatistic - type of transfer - i.e. which bank to which bank at what throughput.ro
Enumeration
.1.3.6.1.4.1.449.2.1.1.5.5
cdx6500DLSVInitiateTransferType of transfer - i.e. which bank to which bank at what throughput setting this initiates the flash to flash transfer.rw
INTEGER
.1.3.6.1.4.1.449.2.1.1.5.6
cdx6500DLSVAgntSegmentSizeThis is the segment size used for accounting purposes with data packets. segmentSizeDisable - segment counting disabled. segmentSize16 - 16 byte segments. segmentSize32 - 32 byte segments. segmentSize64 - 64 byte segments. segmentSize128 - 128 byte segments. segmentSize256 - 256 byte segments. segmentSize512 - 512 byte segments. segmentSize1024 - 1024 byte segments newvalSegmentSizeDisable - same as 'segmentSizeDisable', new enumeration added for RFC1155 compatibility.ro
Enumeration
.1.3.6.1.4.1.449.2.1.1.5.7
cdx6500DLSVAgntnmServAddressThis is the mnemonic name of the download server assigned to load this node with operational software.ro
DisplayString
.1.3.6.1.4.1.449.2.1.1.5.8
cdx6500DLSVagntloaderSubaddressThis is the subaddress of the download module in this node.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.5.9
cdx6500DLSVagntdlServSubaddressCalls with network address composed of the node address (configured in the Node record) and this subaddress will be routed to the module in this node which sends code to a remote node. No routing table entry is needed.ro
INTEGER
.1.3.6.1.4.1.449.2.1.1.5.10
cdx6500Configuration
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.2
cdx6500CfgProtocolGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.2.1
cdx6500PCTPortProtocolGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.2.1.1
cdx6500CreatePortAndStationTableCreate Port and Station table.
SEQUENCE OF Cdx6500CreatePortAndStationEntry
.1.3.6.1.4.1.449.2.1.2.1.9
cdx6500CreatePortAndStationEntryEntry for representing Creating Port and Station Record.
Cdx6500CreatePortAndStationEntry
.1.3.6.1.4.1.449.2.1.2.1.9.1
cdx6500PortNumberPort Number which is installed.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.9.1.1
cdx6500CreatePortTypeport type to be created. pad : PAD port x25 : X25 port mx25 : Multipoint X25 port sdlc : Synchronous Data Link Control Port xdlc : X25 Data Link Control Port fri : Frame Relay Interface Port tr : Token Ring Port eth : Ethernet Port fra : Frame Relay Access Port.rw
Enumeration
.1.3.6.1.4.1.449.2.1.2.1.9.1.2
cdx6500CreateStationstation number to be created. The instance should be existing port number. Station Range : 1 - Max Station Number.rw
INTEGER
.1.3.6.1.4.1.449.2.1.2.1.9.1.3
cdx6500CfgGeneralGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.2.2
cdx6500GCTRouteSelectionTableA list of Configuration Parameters that select the links over which calls are routed.
SEQUENCE OF Cdx6500GCTRouteSelectionEntry
.1.3.6.1.4.1.449.2.1.2.2.1
cdx6500GCTRouteSelectionEntryEach entry contains a list of parameters that makeup the Route Selection Table.
Cdx6500GCTRouteSelectionEntry
.1.3.6.1.4.1.449.2.1.2.2.1.1
cdx6500RoutSVCEntryNumberThis is not a configurable parameter. This identifies the particular Route Selection Table entry being configured by the other parameters in the record.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.2.1.1.1
cdx6500RoutSVCAddressThis is a non-supported object. It has been replaced by cdx6500RoutSVCAddress1.rodeprecated
INTEGER
.1.3.6.1.4.1.449.2.1.2.2.1.1.2
cdx6500RoutSVCDestination1This specifies the network address to which calls are routed. For example: BCST route calls to the broadcast module. BSC2780-4 route calls to BSC2780 port 4. BSC3270-9 route calls to BSC3270 port 9. MX25-2s3 route calls to MX25 port 2, station 3. PAD-5 route calls to PAD port 5. P54s9 route calls to port 54, station 9. SDLC-4s5 route calls to SDLC port 4, station 5. X25-1 route calls to X25 port 1. BOSTON route backup calls to BOSTON resource.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.2.2.1.1.3
cdx6500RoutSVCPriority1This specifies the priority for call forwarding to ports within the Route Selection Table. Call forwarding is determined by a combination of priority and load conditions. 0 - backup port. 1 to 15 - 1 is the highest priority and 15, the lowest.rw
INTEGER
.1.3.6.1.4.1.449.2.1.2.2.1.1.4
cdx6500RoutSVCDestination2This specifies the network address to which calls are routed. For example: BCST route calls to the broadcast module. BSC2780-4 route calls to BSC2780 port 4. BSC3270-9 route calls to BSC3270 port 9. MX25-2s3 route calls to MX25 port 2, station 3. PAD-5 route calls to PAD port 5. P54s9 route calls to port 54, station 9. SDLC-4s5 route calls to SDLC port 4, station 5. X25-1 route calls to X25 port 1. BOSTON route backup calls to BOSTON resource.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.2.2.1.1.5
cdx6500RoutSVCPriority2This specifies the priority for call forwarding to ports within the Route Selection Table. Call forwarding is determined by a combination of priority and load conditions. 0 - backup port. 1 to 15 - 1 is the highest priority and 15, the lowest.rw
INTEGER
.1.3.6.1.4.1.449.2.1.2.2.1.1.6
cdx6500RoutSVCDestination3This specifies the network address to which calls are routed. For example: BCST route calls to the broadcast module. BSC2780-4 route calls to BSC2780 port 4. BSC3270-9 route calls to BSC3270 port 9. MX25-2s3 route calls to MX25 port 2, station 3. PAD-5 route calls to PAD port 5. P54s9 route calls to port 54, station 9. SDLC-4s5 route calls to SDLC port 4, station 5. X25-1 route calls to X25 port 1. BOSTON route backup calls to BOSTON resource.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.2.2.1.1.7
cdx6500RoutSVCPriority3This specifies the priority for call forwarding to ports within the Route Selection Table. Call forwarding is determined by a combination of priority and load conditions. 0 - backup port. 1 to 15 - 1 is the highest priority and 15, the lowest.rw
INTEGER
.1.3.6.1.4.1.449.2.1.2.2.1.1.8
cdx6500RoutSVCDestination4This specifies the network address to which calls are routed. For example: BCST route calls to the broadcast module. BSC2780-4 route calls to BSC2780 port 4. BSC3270-9 route calls to BSC3270 port 9. MX25-2s3 route calls to MX25 port 2, station 3. PAD-5 route calls to PAD port 5. P54s9 route calls to port 54, station 9. SDLC-4s5 route calls to SDLC port 4, station 5. X25-1 route calls to X25 port 1. BOSTON route backup calls to BOSTON resource.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.2.2.1.1.9
cdx6500RoutSVCPriority4This specifies the priority for call forwarding to ports within the Route Selection Table. Call forwarding is determined by a combination of priority and load conditions. 0 - backup port. 1 to 15 - 1 is the highest priority and 15, the lowest.rw
INTEGER
.1.3.6.1.4.1.449.2.1.2.2.1.1.10
cdx6500RoutSVCDestination5This specifies the network address to which calls are routed. For example: BCST route calls to the broadcast module. BSC2780-4 route calls to BSC2780 port 4. BSC3270-9 route calls to BSC3270 port 9. MX25-2s3 route calls to MX25 port 2, station 3. PAD-5 route calls to PAD port 5. P54s9 route calls to port 54, station 9. SDLC-4s5 route calls to SDLC port 4, station 5. X25-1 route calls to X25 port 1. BOSTON route backup calls to BOSTON resource.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.2.2.1.1.11
cdx6500RoutSVCPriority5This specifies the priority for call forwarding to ports within the Route Selection Table. Call forwarding is determined by a combination of priority and load conditions. 0 - backup port. 1 to 15 - 1 is the highest priority and 15, the lowest.rw
INTEGER
.1.3.6.1.4.1.449.2.1.2.2.1.1.12
cdx6500RoutSVCDestination6This specifies the network address to which calls are routed. For example: BCST route calls to the broadcast module. BSC2780-4 route calls to BSC2780 port 4. BSC3270-9 route calls to BSC3270 port 9. MX25-2s3 route calls to MX25 port 2, station 3. PAD-5 route calls to PAD port 5. P54s9 route calls to port 54, station 9. SDLC-4s5 route calls to SDLC port 4, station 5. X25-1 route calls to X25 port 1. BOSTON route backup calls to BOSTON resource.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.2.2.1.1.13
cdx6500RoutSVCPriority6This specifies the priority for call forwarding to ports within the Route Selection Table. Call forwarding is determined by a combination of priority and load conditions. 0 - backup port. 1 to 15 - 1 is the highest priority and 15, the lowest.rw
INTEGER
.1.3.6.1.4.1.449.2.1.2.2.1.1.14
cdx6500RoutSVCDestination7This specifies the network address to which calls are routed. For example: BCST route calls to the broadcast module. BSC2780-4 route calls to BSC2780 port 4. BSC3270-9 route calls to BSC3270 port 9. MX25-2s3 route calls to MX25 port 2, station 3. PAD-5 route calls to PAD port 5. P54s9 route calls to port 54, station 9. SDLC-4s5 route calls to SDLC port 4, station 5. X25-1 route calls to X25 port 1. BOSTON route backup calls to BOSTON resource.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.2.2.1.1.15
cdx6500RoutSVCPriority7This specifies the priority for call forwarding to ports within the Route Selection Table. Call forwarding is determined by a combination of priority and load conditions. 0 - backup port. 1 to 15 - 1 is the highest priority and 15, the lowest.rw
INTEGER
.1.3.6.1.4.1.449.2.1.2.2.1.1.16
cdx6500RoutSVCDestination8This specifies the network address to which calls are routed. For example: BCST route calls to the broadcast module. BSC2780-4 route calls to BSC2780 port 4. BSC3270-9 route calls to BSC3270 port 9. MX25-2s3 route calls to MX25 port 2, station 3. PAD-5 route calls to PAD port 5. P54s9 route calls to port 54, station 9. SDLC-4s5 route calls to SDLC port 4, station 5. X25-1 route calls to X25 port 1. BOSTON route backup calls to BOSTON resource.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.2.2.1.1.17
cdx6500RoutSVCPriority8This specifies the priority for call forwarding to ports within the Route Selection Table. Call forwarding is determined by a combination of priority and load conditions. 0 - backup port. 1 to 15 - 1 is the highest priority and 15, the lowest.rw
INTEGER
.1.3.6.1.4.1.449.2.1.2.2.1.1.18
cdx6500RoutSVCAddress1Network address for calls routed beyond this node. A route selection entry is not needed for calls destined within this node: PAD port or node resource (for example, control port) calls. The wild card(match anything) character is * and can also be part of the entry. When set to (blank), this parameter is ignored.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.2.2.1.1.19
cdx6500GCTPVCSetupTableA list of Configuration Parameters for PVCs.
SEQUENCE OF Cdx6500GCTPVCSetupEntry
.1.3.6.1.4.1.449.2.1.2.2.5
cdx6500GCTPVCSetupEntryEach entry contains a PVC source and PVC destination.
Cdx6500GCTPVCSetupEntry
.1.3.6.1.4.1.449.2.1.2.2.5.1
cdx6500PVCSetupEntryNumberThis is not a configurable parameter. This identifies the particular PVC Table entry being configured by the other parameters in the record.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.2.5.1.1
cdx6500PVCSetupSourceThis is the PVC source channel identifier. Entries are not case sensitive. For example: BCST route calls to the broadcast module. MX25-2s3(2) route calls to MX25 port 2, station 3, channel 2. PAD-5 route calls to PAD port 5. P54S9(22) route calls to port 54, station 9, channel 22. SDLC-4s5 route calls to SDLC port 4, station 5. X25-1(5) route calls to X25 port 1, channel 5.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.2.2.5.1.2
cdx6500PVCSetupDestinationThis is the PVC destination channel identifier. Entries are not case sensitive. For example: BCST route calls to the broadcast module. MX25-2s3(2) route calls to MX25 port 2, station 3, channel 2. PAD-5 route calls to PAD port 5. P54S9(22) route calls to port 54, station 9, channel 22. SDLC-4s5 route calls to SDLC port 4, station 5. X25-1(5) route calls to X25 port 1, channel 5.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.449.2.1.2.2.5.1.3
cdx6500CfgMnemonicTableAll of the configuration parameters relevant to the Mnemonic table.
SEQUENCE OF Cdx6500CfgMnemonicEntry
.1.3.6.1.4.1.449.2.1.2.2.6
cdx6500CfgMnemonicEntryA row of mnemonic configuration parameters.
Cdx6500CfgMnemonicEntry
.1.3.6.1.4.1.449.2.1.2.2.6.1
cdx6500mnemEntryNumThis is not a configuration parameter. Instead, it identifies the particular Mnemonic Table entry being configured by the other parameters in the record. NOTE: You can have up to 256 entries for the 6507Plus and 6525Plus, but only 64 entries for the 6505Plus.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.2.6.1.1
cdx6500mnemNameThis is an mnemonic name available to PAD port users for abbreviated calling or autocalling. The following parameter will specify call details. The mnemonic CTP is reserved and specifies a call to the control port.ro
DisplayString
.1.3.6.1.4.1.449.2.1.2.2.6.1.2
cdx6500mnemx28CmdThis specifies call details for the mnemonic configured in the previous parameter. Use the format of an X.28 call command, but leave out the command specifier (the c or call).ro
DisplayString
.1.3.6.1.4.1.449.2.1.2.2.6.1.3
cdx6500GCTNUIPasswordTableA list of NUI/Password configuration entries.
SEQUENCE OF Cdx6500GCTNUIPasswordEntry
.1.3.6.1.4.1.449.2.1.2.2.7
cdx6500GCTNUIPasswordEntryThe Network User Identification (NUI)/Password Table.
Cdx6500GCTNUIPasswordEntry
.1.3.6.1.4.1.449.2.1.2.2.7.1
cdx6500NUITEntryNumberThis is not a configurable parameter. Instead, it identifies the particular NUI/Password Table entry being configured by the other parameters in the record.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.2.7.1.1
cdx6500NUITAcctNameThis is the account name for billing records.ro
DisplayString
.1.3.6.1.4.1.449.2.1.2.2.7.1.2
cdx6500NUITPasswdThis is the password for the account name.ro
DisplayString
.1.3.6.1.4.1.449.2.1.2.2.7.1.3
cdx6500NUITPADPromptNumThis parameter specifies which entry in the PAD Prompt Table is used as a PAD prompt after the user has entered a valid password. Use 0 for standard asterisk prompt.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.2.7.1.4
cdx6500GCTSoftwareKeyTableA table of Software Key configuration entries.
SEQUENCE OF Cdx6500GCTSoftwareKeyEntry
.1.3.6.1.4.1.449.2.1.2.2.12
cdx6500GCTSoftwareKeyEntryThe Software Key for a specific optional software product code.
Cdx6500GCTSoftwareKeyEntry
.1.3.6.1.4.1.449.2.1.2.2.12.1
cdx6500CSISSoftKeyEntryNumberThis is not a configurable parameter. It is the reference number for the individual software option that is being enabled. You must configure a separate entry for each software option enabled at the node. A node may have up to 20 options enabled at one time.ro
INTEGER
.1.3.6.1.4.1.449.2.1.2.2.12.1.1
cdx6500CSISSoftKeyValueThis is a software key supplied by Codex Corporation for this node.ro
DisplayString
.1.3.6.1.4.1.449.2.1.2.2.12.1.2
cdx6500Statistics
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.3
cdx6500StatProtocolGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.3.1
cdx6500PSTPortProtocolGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.3.1.1
cdx6500PPSTallPortsTableAll of the statistics parameters relevant to the allPorts table.
SEQUENCE OF Cdx6500PPSTallPortsEntry
.1.3.6.1.4.1.449.2.1.3.1.1.18
cdx6500PPSTallPortsEntryA row of allPorts statistics parameters.
Cdx6500PPSTallPortsEntry
.1.3.6.1.4.1.449.2.1.3.1.1.18.1
cdx6500allportsPortNumNumber of the portro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.18.1.1
cdx6500allportsPortTypeType of port.ro
Enumeration
.1.3.6.1.4.1.449.2.1.3.1.1.18.1.2
cdx6500allportsPortStatusStatus of the port. disabled - Port is disabled. enabled - Port is enabled. busyOut - Port is busyOuted. up - Port is up. down - Port is down. newvalDisabled - same functionality as 'disabled', new enumeration added for RFC1155 compatibility.ro
Enumeration
.1.3.6.1.4.1.449.2.1.3.1.1.18.1.3
cdx6500allportsPortStateCurrent Port state.ro
DisplayString
.1.3.6.1.4.1.449.2.1.3.1.1.18.1.4
cdx6500allportsPortSpeedThis is the speed of the port when Clock=Int; this is detected clock speed if Clock=Ext. If Port Speed is 0, Clock=Ext then clocking is not being received from attached device.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.18.1.5
cdx6500allportsUtilizationInPercentage of port bandwidth in use.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.18.1.6
cdx6500allportsUtilizationOutPercentage of port bandwidth in use.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.18.1.7
cdx6500allportsCharInTotNumber of characters received by the port since the last node, port or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.1.18.1.8
cdx6500allportsCharOutTotNumber of characters sent by the port since the last node, port or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.1.18.1.9
cdx6500allportsPktInTotNumber of packets received by the port since the last node, port or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.1.18.1.10
cdx6500allportsPktOutTotNumber of packets sent by the port since the last node, port or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.1.18.1.11
cdx6500allportsFrameInTotNumber of frames received by the port since the last node, port or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.1.18.1.12
cdx6500allportsFrameOutTotNumber of frames sent by the port since the last node, port or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.1.18.1.13
cdx6500allportsPktsQueuedNumber of packets currently queued.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.18.1.14
cdx6500allportsCharsInPerSecSummary of the characters being received over the port.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.18.1.15
cdx6500allportsCharsOutPerSecSummary of the characters being sent over the port.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.18.1.16
cdx6500allportsPktsInPerSecSummary of the packets being received over the port.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.18.1.17
cdx6500allportsPktsOutPerSecSummary of the packets being sent over the port.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.18.1.18
cdx6500allportsFramesInPerSecSummary of the frames being received over the port.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.18.1.19
cdx6500allportsFramesOutPerSecSummary of the frames being sent over the port.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.1.18.1.20
cdx6500allportsOverrunErrorsNumber of Overrun errors since the last node or statistics reset. Overrun Errors: Received data was lost because it could not be processed by the CPU.ro
Counter16
.1.3.6.1.4.1.449.2.1.3.1.1.18.1.21
cdx6500allportsUnderrunErrorsNumber of Underrun errors since the last node or statistics reset. UnderrunErrors: Transmission of a frame could not be completed because all the data had not been sent to port.ro
Counter16
.1.3.6.1.4.1.449.2.1.3.1.1.18.1.22
cdx6500allportsCRCErrorsNumber of CRC errors since the last node or statistics reset. CRC Errors: Cyclical Redundancy failure because of noise on the line.ro
Counter16
.1.3.6.1.4.1.449.2.1.3.1.1.18.1.23
cdx6500allportsParityErrorsNumber of Parity errors since the last resetro
Counter16
.1.3.6.1.4.1.449.2.1.3.1.1.18.1.24
cdx6500allportsFramingErrorsNumber of Framing errors since the last reset.ro
Counter16
.1.3.6.1.4.1.449.2.1.3.1.1.18.1.25
cdx6500allportsBootPortBoots the specified Port. bootPort - Boot the Port.rw
Enumeration
.1.3.6.1.4.1.449.2.1.3.1.1.18.1.26
cdx6500allportsPortControlStatusChange the Port Control Status. enable - Enable the Port. disable - Disable the Port. busyout - BusyOut the Port.rw
Enumeration
.1.3.6.1.4.1.449.2.1.3.1.1.18.1.27
cdx6500PSTStationProtocolGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.3.1.3
cdx6500SPSTallStationsTableAll of the statistics parameters relevant to the allStations table.
SEQUENCE OF Cdx6500SPSTallStationsEntry
.1.3.6.1.4.1.449.2.1.3.1.3.8
cdx6500SPSTallStationsEntryA row of allStations statistics parameters.
Cdx6500SPSTallStationsEntry
.1.3.6.1.4.1.449.2.1.3.1.3.8.1
cdx6500allstationsPortNumNumber of the port.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.8.1.1
cdx6500allstationsStnNumNumber of the station.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.8.1.2
cdx6500allstationsStnTypeType of station.ro
DisplayString
.1.3.6.1.4.1.449.2.1.3.1.3.8.1.3
cdx6500allstationsStnStatusStatus of the station. disabled - Station is disabled. enabled - Station is enabled. busyOut - Station is busyOuted. up - Station is up. down - Station is down. newvalDisabled - same functionality as 'disabled', new enumeration added for RFC1155 compatibility.ro
Enumeration
.1.3.6.1.4.1.449.2.1.3.1.3.8.1.4
cdx6500allstationsStnStateCurrent Station state.ro
DisplayString
.1.3.6.1.4.1.449.2.1.3.1.3.8.1.5
cdx6500allstationsUtilizationInPercentage of station bandwidth in use.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.8.1.6
cdx6500allstationsUtilizationOutPercentage of station bandwidth in use.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.8.1.7
cdx6500allstationsCharInTotNumber of characters received by the station since the last node, port, station or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.8.1.8
cdx6500allstationsCharOutTotNumber of characters sent by the station since the last node, port, station or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.8.1.9
cdx6500allstationsPktInTotNumber of packets received by the station since the last node, port, station or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.8.1.10
cdx6500allstationsPktOutTotNumber of packets sent by the port since the last node, port, station or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.8.1.11
cdx6500allstationsFrameInTotNumber of frames received by the port since the last node, port, station or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.8.1.12
cdx6500allstationsFrameOutTotNumber of frames sent by the port since the last node, port, station or statistics reset.ro
Counter
.1.3.6.1.4.1.449.2.1.3.1.3.8.1.13
cdx6500allstationsPktsQueuedNumber of packets currently queued.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.8.1.14
cdx6500allstationsCharsInPerSecSummary of the characters being received over the station.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.8.1.15
cdx6500allstationsCharsOutPerSecSummary of the characters being sent over the station.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.8.1.16
cdx6500allstationsPktsInPerSecSummary of the packets being received over the station.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.8.1.17
cdx6500allstationsPktsOutPerSecSummary of the packets being sent over the station.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.8.1.18
cdx6500allstationsFramesInPerSecSummary of the frames being received over the station.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.8.1.19
cdx6500allstationsFramesOutPerSecSummary of the frames being sent over the station.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.1.3.8.1.20
cdx6500allstationsBootStationBoots the specified station. bootStn - Boot Station noBootStn - Do not boot Station.rw
Enumeration
.1.3.6.1.4.1.449.2.1.3.1.3.8.1.21
cdx6500allstationsDisableStationDisables the specified station. disableStn - Disable Station. noDisableStn - Do not disable Station.rw
Enumeration
.1.3.6.1.4.1.449.2.1.3.1.3.8.1.22
cdx6500allstationsEnableStationEnables the specified station. enableStn - Enable Station. noEnableStn - Not not enable Station.rw
Enumeration
.1.3.6.1.4.1.449.2.1.3.1.3.8.1.23
cdx6500allstationsBusyOutStationBusy out the specified station. busyoutStn - Busyout Station. noBusyoutStn - Do not busyout Station.rw
Enumeration
.1.3.6.1.4.1.449.2.1.3.1.3.8.1.24
cdx6500PSTLANConnectionGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.3.1.6
cdx6500StatOtherStatsGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.3.2
cdx6500OSTCSISOptionStatTableA table describing the Software Options that have been purchased and enabled for this node.
SEQUENCE OF Cdx6500OSTCSISOptionStatEntry
.1.3.6.1.4.1.449.2.1.3.2.5
cdx6500OSTCSISOptionStatEntryA list of objects describing a single Software Option.
Cdx6500OSTCSISOptionStatEntry
.1.3.6.1.4.1.449.2.1.3.2.5.1
cdx6500CSISOptionNumberTable index, which is code for the software option. Following are the various software options and their codes. 1 - MX25 2 - SDLC 3 - BSC3270 4 - BSC2780 5 - VIP 6 - VIDEOTEX 7 - Data/Connection Protect 8 - INL backup 9 - FR DTE Interface 10 - 6600 ETM 11 - NCRBSC 12 - TRANSPARENT POLLED ASYNC 13 - INTERNAL DSD 14 - 801 AUTODIALER 15 - BSTD 16 - FLASH Enable 17 - NCCP Pad 18 - TBOP 19 - Source Routing Bridge 22 - IBM2260 23 - XDLC 24 - Transparent Bridge 25 - Local Termination 26 - SR/TB Bridge 29 - IP Routing 31 - FR DCE Interface 32 - 6520 Model ID RN 33 - 6520 Model ID SN 34 - 6520 Model ID BN 40 - TCOP 42 - FrameRelay LLC Conversion 43 - IP stack on CPU+ 44 - TNPP-PAD Enable 45 - Token Ring LLC Conversion 46 - Ethernet LLC Conversion 50 - Dial-Out Routing Manager 51 - Dial-Out Routing Agent 52 - Chinapac Billing Feature 53 - Chinapac NUIC Interface 54 - X32 Port 55 - Chinapac NUI Concentrator.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.2.5.1.1
cdx6500CSISMaxAllowedNumber of ports that this option can support. Options can be purchased to support different numbers of ports. Value of 65535 indicates no limit.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.2.5.1.2
cdx6500CSISNumUsedThe number of ports actually being used with this option.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.2.5.1.3
cdx6500CSISOptionAuthunauthorized - an attempt was made to use an option that has not been purchased or enabled. authorized - all attempts to use the option were authorized.ro
Enumeration
.1.3.6.1.4.1.449.2.1.3.2.5.1.4
cdx6500OSTCSISPortUsageTableA table providing statistics on unauthorized port usage.
SEQUENCE OF Cdx6500OSTCSISPortUsageEntry
.1.3.6.1.4.1.449.2.1.3.2.6
cdx6500OSTCSISPortUsageEntryA list of authorization statistics for a single port.
Cdx6500OSTCSISPortUsageEntry
.1.3.6.1.4.1.449.2.1.3.2.6.1
cdx6500CSISPortNumberThe port's number.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.2.6.1.1
cdx6500CSISPortAuthunauthorized - an attempt was made to use this port to exceed an option port limit. authorized - the port was not used in an unauthorized fashion.ro
Enumeration
.1.3.6.1.4.1.449.2.1.3.2.6.1.2
cdx6500StatTFTPGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.3.3
cdx6500StatNetworkSvcsGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.3.4
cdx6500StatSVCTableA table of currently active switched virtual circuits (SVC). The table is dynamic i.e. changing as queries are being performed on the table.
SEQUENCE OF Cdx6500StatSVCEntry
.1.3.6.1.4.1.449.2.1.3.4.1
cdx6500StatSVCEntryA list of objects describing a single SVC.
Cdx6500StatSVCEntry
.1.3.6.1.4.1.449.2.1.3.4.1.1
cdx6500StatSVCIndexIt is position in the list of SVC's.ro
INTEGER
.1.3.6.1.4.1.449.2.1.3.4.1.1.1
cdx6500StatSVCCallingChannelCalling channel of SVC.ro
DisplayString
.1.3.6.1.4.1.449.2.1.3.4.1.1.2
cdx6500StatSVCCalledChannelCalled channel of SVC.ro
DisplayString
.1.3.6.1.4.1.449.2.1.3.4.1.1.3
cdx6500StatSVCReverseChargeReverse charge facility condition. refuse - Refused the condition. accept - Accepted the condition. newvalRefuse - same functionality as 'refuse', new enumeration added for RFC1155 compatibility.ro
Enumeration
.1.3.6.1.4.1.449.2.1.3.4.1.1.4
cdx6500StatSVCFastSelectFast select facility condition. noFastSelect - Fast select facility is not selected. fastSelect - Fast select facility is selected. newvalNoFastSelect - same functionality as 'noFastSelect', new enumeration added for RFC1155 compatibility.ro
Enumeration
.1.3.6.1.4.1.449.2.1.3.4.1.1.5
cdx6500StatSVCNetUserIdentificationNet user identifiaction facility condition. notRequested - Net user identifiaction facility not requested. requested - Net user identifiaction facility requested. newvalNotRequested - same functionality as 'notRequested', new enumeration added for RFC1155 compatibility.ro
Enumeration
.1.3.6.1.4.1.449.2.1.3.4.1.1.6
cdx6500StatSVCClosedUserGroupClosed user group facility on/off. notRequested - Closed user group facility off. requested - Closed user group facility on. newvalNotRequested - same functionality as 'notRequested', new enumeration added for RFC1155 compatibility.ro
Enumeration
.1.3.6.1.4.1.449.2.1.3.4.1.1.7
cdx6500StatSVCConnectionUPTimeTime at which connection was up.ro
DisplayString
.1.3.6.1.4.1.449.2.1.3.4.1.1.8
cdx6500Controls
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.4
cdx6500ContTFTP
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.4.2
cdx6500statControls
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.4.4
cdx6500statResetAllStatsA control object that when set to reset will cause the node to reset ALL its statistics. reset - reset ALL node statistics. noReset - Do not reset the statistics.rw
Enumeration
.1.3.6.1.4.1.449.2.1.4.4.1
cdx6500ContFlash
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.4.21
cdx6500ContFlashCopyImageCopy image from current to alternate or alternate to current.rw
Enumeration
.1.3.6.1.4.1.449.2.1.4.21.1
cdx6500ContFlashCopyCmemCopy cmem from current to alternate or alternate to current.rw
Enumeration
.1.3.6.1.4.1.449.2.1.4.21.2
cdx6500ContFlashActiveImageActivate image in flash memory.rw
Enumeration
.1.3.6.1.4.1.449.2.1.4.21.3
cdx6500ContFlashActiveCmemActivate cmem in flash memory.rw
Enumeration
.1.3.6.1.4.1.449.2.1.4.21.4
cdx6500ContFlashDeleteImageDelete all images in flash memory.rw
Enumeration
.1.3.6.1.4.1.449.2.1.4.21.5
cdx6500ContT3E3Table
OBJECT IDENTIFIER
.1.3.6.1.4.1.449.2.1.4.23
cdx6500T3E3ContEntryEach control applies to a single T3E3 port.
Cdx6500T3E3ContEntry
.1.3.6.1.4.1.449.2.1.4.23.1
t3e3ContPortNumberPort number of the T3E3 port.
INTEGER
.1.3.6.1.4.1.449.2.1.4.23.1.1
t3e3ContPortControlControl operations for the specified T3E3 port. boot - Boots the T3E3 port enable - Enables the T3E3 port disable - Disables the T3E3 port resetstats - Resets the T3E3 port statistics.rw
Enumeration
.1.3.6.1.4.1.449.2.1.4.23.1.2
CDX-6500-COMMON-MIB - SNMP MIB Reference | MIBs Explorer