SPEEDCARRIER-MIB

AI MIB Summary

The SPEEDCARRIER-MIB provides SNMP management access to Speed Carrier hardware and its associated management cards, exposing operational status, interface statistics, and device health metrics for telecommunications carrier equipment.

This MIB module defines objects for the SPEED CARRIER and the management card
Main OID:
nmSPEEDCARRIER.1.3.6.1.4.1.3652.3
413
Objects
Active
Status
3
Dependencies

Imported Objects

Objects

413 total
Object Name
coldStartColdStart
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.40
rebootReboot
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.41
fanErrorFANError
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.42
fanOKFANOK
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.43
powerFailurePowerFailure
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.44
powerOKPowerOK
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.45
highTempHighTemp
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.46
tempOKTempOK
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.47
transceiverRemovedSFPRemoved
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.48
transceiverInsertedSFPInserted
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.49
moduleInsertedModuleInserted
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.50
moduleRemovedModuleRemoved
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.51
portTxUpPortTxUp
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.52
portTxDownPortTxDown
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.53
portUpPortUp
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.54
portDownPortDown
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.55
txFaultTxFault
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.56
badPasswdBadPasswd
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.57
softwareUpdateReadySoftwareUpdateReady
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.58
hardwareTrapHardwareTrap
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.59
cdrAlarmCDRAlarm
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.60
protectionMainProtectionMain
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.61
protectionBackupProtectionBackup
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.62
optRxLevelWarningOptRxLevelWarning
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.63
optRxLevelAlarmOptRxLevelAlarm
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.64
optRxLevelOKOptRxLevelOK
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.65
optTxLevelWarningOptTxLevelWarning
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.66
optTxLevelAlarmOptTxLevelAlarm
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.67
optTxLevelOKOptTxLevelOK
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.68
optTxBiasAlarmTX Bias Alarm
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.69
optTxBiasOKTX Bias OK
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.70
optRxPowerOverloadHigh optical input power Alarm
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.71
configErrorConfiguration error. An set command or config file transfer was not successful.
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.72
configurationConfiguration file information
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.73
maintenanceMaintennance Change
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.74
ampFailAMP error is occured
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.75
ampOkAMP error is cleared
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.76
dwdmAlarmDWDM transceiver alarm occured
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.77
dwdmOkDWDM transceiver alarm cleared
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.78
firmwareErrorfirmware or kernel transfer or flashing error
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.79
tuningErrortransceiver tuning error
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.80
encryptionencryption error
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.81
emergencyShutdownCarrier Emergency Shutdown
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.82
unspecifiedUnspecified
NOTIFICATION-TYPE
.1.3.6.1.4.1.3652.0.255
nmSPEEDCARRIERThis MIB module defines objects for the SPEED CARRIER and the management card
MODULE-IDENTITY
.1.3.6.1.4.1.3652.3
nmAgent
OBJECT IDENTIFIER
.1.3.6.1.4.1.3652.3.1
nmAgentGeneralInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.3652.3.1.1
nmARamdiskVersionSPEED-NMS Ramdisk Versionro
DisplayString
.1.3.6.1.4.1.3652.3.1.1.1
nmASlotSlot in which the SPEED-NMS card is insertedro
Integer32
.1.3.6.1.4.1.3652.3.1.1.2
nmADateDate of the SPEED-NMS systemro
DisplayString
.1.3.6.1.4.1.3652.3.1.1.3
nmATimeActual Time of the SPEED-NMS systemro
DisplayString
.1.3.6.1.4.1.3652.3.1.1.4
nmAUpTimeSystem uptime of the SPEED-NMS systemro
DisplayString
.1.3.6.1.4.1.3652.3.1.1.5
nmATemperatureBoard temperature of the SPEED-NMS systemro
Integer32
.1.3.6.1.4.1.3652.3.1.1.6
nmAAlarmStateAlarm state of the SPEED-NMS systemro
Enumeration
.1.3.6.1.4.1.3652.3.1.1.7
nmASerialNumberSerial number of the SPEED-NMS systemro
DisplayString
.1.3.6.1.4.1.3652.3.1.1.8
nmAKernelVersionSPEED-NMS Kernel Versionro
DisplayString
.1.3.6.1.4.1.3652.3.1.1.9
nmASoftwareVersionSPEED-NMS Software Versionro
DisplayString
.1.3.6.1.4.1.3652.3.1.1.10
nmAgentConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.3652.3.1.2
nmAgentConfigNetwork
OBJECT IDENTIFIER
.1.3.6.1.4.1.3652.3.1.2.1
nmAgentConfigNetworkIPIP-address of the management boards Ethernet interfacerw
IpAddress
.1.3.6.1.4.1.3652.3.1.2.1.1
nmAgentConfigNetworkMaskIP-netmask of the management boards Ethernet interfacerw
IpAddress
.1.3.6.1.4.1.3652.3.1.2.1.2
nmAgentConfigNetworkGatewaydefault gateway of the management boards Ethernet interfacerw
IpAddress
.1.3.6.1.4.1.3652.3.1.2.1.3
nmAgentConfigNetworkIPv6IPv6-address of the management boards Ethernet interfacerw
DisplayString
.1.3.6.1.4.1.3652.3.1.2.1.5
nmAgentConfigNetworkGatewayv6default gatewayv6 of the management boards Ethernet interfacerw
DisplayString
.1.3.6.1.4.1.3652.3.1.2.1.6
nmAgentConfigSnmp
OBJECT IDENTIFIER
.1.3.6.1.4.1.3652.3.1.2.2
nmAgentConfigSnmpReadCommunitySNMP read community namerw
DisplayString
.1.3.6.1.4.1.3652.3.1.2.2.1
nmAgentConfigSnmpWriteCommunitySNMP write community namerw
DisplayString
.1.3.6.1.4.1.3652.3.1.2.2.2
nmAgentConfigSnmpSysLocationlocation of the SPEED-CARRIER systemrw
DisplayString
.1.3.6.1.4.1.3652.3.1.2.2.3
nmAgentConfigSnmpSysContactadministrator of the SPEED-CARRIER systemrw
DisplayString
.1.3.6.1.4.1.3652.3.1.2.2.4
nmAgentConfigSnmpTrapSink1Trap destination 1 for SNMP traps. Clear value is 0.0.0.0rw
DisplayString
.1.3.6.1.4.1.3652.3.1.2.2.5
nmAgentConfigSnmpTrapSink2Trap destination 2 for SNMP traps. Clear value is 0.0.0.0rw
DisplayString
.1.3.6.1.4.1.3652.3.1.2.2.6
nmAgentConfigSnmpTrapSink3Trap destination 3 for SNMP traps. Clear value is 0.0.0.0rw
DisplayString
.1.3.6.1.4.1.3652.3.1.2.2.7
nmAgentConfigSnmpTrapSink4Trap destination 4 for SNMP traps. Clear value is 0.0.0.0rw
DisplayString
.1.3.6.1.4.1.3652.3.1.2.2.8
nmAgentConfigSnmpTrapSink5Trap destination 5 for SNMP traps. Clear value is 0.0.0.0rw
DisplayString
.1.3.6.1.4.1.3652.3.1.2.2.9
nmAgentConfigSnmpAgentenable or disable the SNMP agent on the management boardrw
Enumeration
.1.3.6.1.4.1.3652.3.1.2.2.10
nmAgentConfigSNMPv3UserConfigTableSNMPv3 user configuration table
SEQUENCE OF NMAgentConfigSNMPv3UserConfigEntry
.1.3.6.1.4.1.3652.3.1.2.2.11
nmAgentConfigSNMPv3UserConfigEntrySNMPv3 user configuration table
NMAgentConfigSNMPv3UserConfigEntry
.1.3.6.1.4.1.3652.3.1.2.2.11.1
nmAgentConfigSNMPv3UserConfigIndexuser indexro
Integer32
.1.3.6.1.4.1.3652.3.1.2.2.11.1.1
nmAgentConfigSnmpv3UserConfigNameuser namerw
DisplayString
.1.3.6.1.4.1.3652.3.1.2.2.11.1.2
nmAgentConfigSnmpv3UserConfigUserLeveluser rights read-only (ro) or read-write (rw)rw
Enumeration
.1.3.6.1.4.1.3652.3.1.2.2.11.1.3
nmAgentConfigSnmpv3UserConfigAuthTypeauthentication typesrw
Enumeration
.1.3.6.1.4.1.3652.3.1.2.2.11.1.4
nmAgentConfigSnmpv3UserConfigAuthPassPhraseauthentication passphraserw
DisplayString
.1.3.6.1.4.1.3652.3.1.2.2.11.1.5
nmAgentConfigSnmpv3UserConfigEncTypeprivacy protocolsrw
Enumeration
.1.3.6.1.4.1.3652.3.1.2.2.11.1.6
nmAgentConfigSnmpv3UserConfigPrivPassPhraseprivacy passphraserw
DisplayString
.1.3.6.1.4.1.3652.3.1.2.2.11.1.7
nmAgentConfigSlotAlarmsTableTable for Slot 'alarm relay' configuration
SEQUENCE OF NMAgentConfigSlotAlarmsEntry
.1.3.6.1.4.1.3652.3.1.2.3
nmAgentConfigSlotAlarmsEntryactivate or deactivate slot for 'alarm relay' configuration
NMAgentConfigSlotAlarmsEntry
.1.3.6.1.4.1.3652.3.1.2.3.1
nmAgentConfigSlotAlarmsSlotNumberSlot number for alarm relay configurationro
Integer32
.1.3.6.1.4.1.3652.3.1.2.3.1.1
nmAgentConfigSlotAlarmsInsertedCardCard type of inserted card in this slotro
DisplayString
.1.3.6.1.4.1.3652.3.1.2.3.1.2
nmAgentConfigSlotAlarmsConfigset alarm reporting to 'on' or 'off' for this slotrw
Enumeration
.1.3.6.1.4.1.3652.3.1.2.3.1.3
nmAgentConfigSlotModulesTableTable for card configuration
SEQUENCE OF NMAgentConfigSlotModulesEntry
.1.3.6.1.4.1.3652.3.1.2.4
nmAgentConfigSlotModulesEntryTable for card configuration
NMAgentConfigSlotModulesEntry
.1.3.6.1.4.1.3652.3.1.2.4.1
nmAgentConfigModulesSlotNumberslot number for card configurationro
Integer32
.1.3.6.1.4.1.3652.3.1.2.4.1.1
nmAgentConfigModulesInstalledCardCard type of inserted card in this slotro
DisplayString
.1.3.6.1.4.1.3652.3.1.2.4.1.2
nmAgentConfigModulesExpectedCardset the type of card, which is inserted in slotrw
Enumeration
.1.3.6.1.4.1.3652.3.1.2.4.1.3
nmAgentConfigModulesSlotTextset the user defined text for passive card, which is inserted in slotrw
DisplayString
.1.3.6.1.4.1.3652.3.1.2.4.1.4
nmAgentConfigModulesInstalledStateCheck the installed module against the expected modulero
DisplayString
.1.3.6.1.4.1.3652.3.1.2.4.1.5
nmAgentConfigAlarmRelayconfigure alarm relay for different sourcesrw
Enumeration
.1.3.6.1.4.1.3652.3.1.2.7
nmAgentConfigFANconfigure fans to 'allOn' or 'auto'rw
Enumeration
.1.3.6.1.4.1.3652.3.1.2.8
nmAgentConfigNtpServerIP address of the Network Time Protocol server. Clear value is '0.0.0.0'.rw
DisplayString
.1.3.6.1.4.1.3652.3.1.2.9
nmAgentConfigTftpServerenable or disable the TFTP server on the management boardrw
Enumeration
.1.3.6.1.4.1.3652.3.1.2.10
nmAgentConfigWebServerenable or disable the web server on the management boardrw
Enumeration
.1.3.6.1.4.1.3652.3.1.2.11
nmAgentConfigMyWebViewconfigures the start screen of WebView for the web interfacerw
Enumeration
.1.3.6.1.4.1.3652.3.1.2.12
nmAgentConfigTimezonesets the system time zone. Has only effect after rebootrw
Enumeration
.1.3.6.1.4.1.3652.3.1.2.15
nmAgentConfigAccesssets system access to telnet, SSH version 2 or offrw
Enumeration
.1.3.6.1.4.1.3652.3.1.2.16
nmAgentConfigCliTimeouttime without user interaction before exiting CLI. Valid range 120-3600 seconds.rw
Integer32
.1.3.6.1.4.1.3652.3.1.2.17
nmAgentConfigRadiusStateConfiglocal or radius, local authenticationrw
Enumeration
.1.3.6.1.4.1.3652.3.1.2.19
nmAgentConfigNMSStaterunning state of NMS module. Reboot is NOT traffic effecting!rw
Enumeration
.1.3.6.1.4.1.3652.3.1.2.21
nmAgentConfigRadiusServerConfigTableRADIUS server configuration table
SEQUENCE OF NMAgentConfigRadiusServerConfigEntry
.1.3.6.1.4.1.3652.3.1.2.26
nmAgentConfigRadiusServerConfigEntryRADIUS server configuration table
NMAgentConfigRadiusServerConfigEntry
.1.3.6.1.4.1.3652.3.1.2.26.1
nmAgentConfigRadiusServerConfigNumberRADIUS server numberro
Integer32
.1.3.6.1.4.1.3652.3.1.2.26.1.1
nmAgentConfigRadiusServerConfigIPAddressRADIUS server IPv4 or IPv6 addressrw
DisplayString
.1.3.6.1.4.1.3652.3.1.2.26.1.2
nmAgentConfigRadiusServerConfigSharedSecretRADIUS server shared secretrw
DisplayString
.1.3.6.1.4.1.3652.3.1.2.26.1.3
nmAgentConfigSyslogServerIPAddressSyslog server IPv4 or IPv6 addressrw
DisplayString
.1.3.6.1.4.1.3652.3.1.2.27
nmAgentConfigSyslogSeverityconfigures the syslog severityrw
Enumeration
.1.3.6.1.4.1.3652.3.1.2.28
nmAgentConfigSyslogFacilityconfigures the syslog facilityrw
Enumeration
.1.3.6.1.4.1.3652.3.1.2.29
nmAgentPorts
OBJECT IDENTIFIER
.1.3.6.1.4.1.3652.3.1.3
nmAgentPortsPortOverviewTablePort overview table
SEQUENCE OF NmAgentPortsPortOverviewEntry
.1.3.6.1.4.1.3652.3.1.3.1
nmAgentPortsPortOverviewEntryPort overview entries
NmAgentPortsPortOverviewEntry
.1.3.6.1.4.1.3652.3.1.3.1.1
nmAgentPortsIndexIndex
Integer32
.1.3.6.1.4.1.3652.3.1.3.1.1.1
nmAgentPortsSlotSlot numberro
Integer32
.1.3.6.1.4.1.3652.3.1.3.1.1.2
nmAgentPortsPortPort numberro
Integer32
.1.3.6.1.4.1.3652.3.1.3.1.1.3
nmAgentPortsAdminConfigPort admin configrw
Enumeration
.1.3.6.1.4.1.3652.3.1.3.1.1.4
nmAgentPortsOperStateSFPSFP Ports operational statero
Enumeration
.1.3.6.1.4.1.3652.3.1.3.1.1.5
nmAgentPortsAlarmStatePort alarm statero
Enumeration
.1.3.6.1.4.1.3652.3.1.3.1.1.6
nmAgentPortsPortTypePort typero
DisplayString
.1.3.6.1.4.1.3652.3.1.3.1.1.7
nmAgentPortsPortDescriptionPort descriptionrw
DisplayString
.1.3.6.1.4.1.3652.3.1.3.1.1.8
nmAgentPortsOperStateCopperCopper Ports operational statero
Enumeration
.1.3.6.1.4.1.3652.3.1.3.1.1.9
nmAgentPortsSFPOverviewTableSFP overview table
SEQUENCE OF NmAgentPortsSFPOverviewEntry
.1.3.6.1.4.1.3652.3.1.3.2
nmAgentPortsSFPOverviewEntryModule transceiver overview entries
NmAgentPortsSFPOverviewEntry
.1.3.6.1.4.1.3652.3.1.3.2.1
nmAgentPortsSFPIndexIndex
Integer32
.1.3.6.1.4.1.3652.3.1.3.2.1.1
nmAgentPortsSFPSlotSlot numberro
Integer32
.1.3.6.1.4.1.3652.3.1.3.2.1.2
nmAgentPortsSFPPortPort numberro
Integer32
.1.3.6.1.4.1.3652.3.1.3.2.1.3
nmAgentPortsSFPStateSFP statero
Enumeration
.1.3.6.1.4.1.3652.3.1.3.2.1.4
nmAgentPortsDMIStateDMI statero
Integer32
.1.3.6.1.4.1.3652.3.1.3.2.1.5
nmAgentPortsVendorNameTransceiver vendor namero
DisplayString
.1.3.6.1.4.1.3652.3.1.3.2.1.6
nmAgentPortsVendorPartNumberTransceiver part numberro
DisplayString
.1.3.6.1.4.1.3652.3.1.3.2.1.7
nmAgentPortsVendorSerialNumberTransceiver serial numberro
DisplayString
.1.3.6.1.4.1.3652.3.1.3.2.1.8
nmAgentPortsWavelengthTransceiver supported wavelength (nm)ro
Integer32
.1.3.6.1.4.1.3652.3.1.3.2.1.9
nmAgentPortsSFPMeassurementTableSFP DMI meassurement table
SEQUENCE OF NmAgentPortsSFPMeassurementEntry
.1.3.6.1.4.1.3652.3.1.3.3
nmAgentPortsSFPMeassurementEntryModule transceiver DMI meassurement entries
NmAgentPortsSFPMeassurementEntry
.1.3.6.1.4.1.3652.3.1.3.3.1
nmAgentPortsSFPMIndexIndex
Integer32
.1.3.6.1.4.1.3652.3.1.3.3.1.1
nmAgentPortsSFPMSlotSlot numberro
Integer32
.1.3.6.1.4.1.3652.3.1.3.3.1.2
nmAgentPortsSFPMPortPort numberro
Integer32
.1.3.6.1.4.1.3652.3.1.3.3.1.3
nmAgentPortsSFPDMIRxLeveloptical receive level (dBm value * 100)ro
Integer32
.1.3.6.1.4.1.3652.3.1.3.3.1.4
nmAgentPortsSFPDMITxLeveloptical transmit level (dBm value * 100)ro
Integer32
.1.3.6.1.4.1.3652.3.1.3.3.1.5
nmAgentPortsSFPDMITxBiasTransceiver hardware parameter: bias current (mA)ro
Integer32
.1.3.6.1.4.1.3652.3.1.3.3.1.6
nmAgentPortsSFPDMIVccTransceiver hardware parameter: supply voltagero
Integer32
.1.3.6.1.4.1.3652.3.1.3.3.1.7
nmAgentPortsSFPDMITempTransceiver hardware parameter: temperature (degree Celsius)ro
Integer32
.1.3.6.1.4.1.3652.3.1.3.3.1.8
nmAgentPortsSFPAlarmTableSFP alarm table
SEQUENCE OF NmAgentPortsSFPAlarmEntry
.1.3.6.1.4.1.3652.3.1.3.4
nmAgentPortsSFPAlarmEntryModule transceiver alarm entries
NmAgentPortsSFPAlarmEntry
.1.3.6.1.4.1.3652.3.1.3.4.1
nmAgentPortsSFPAIndexIndex
Integer32
.1.3.6.1.4.1.3652.3.1.3.4.1.1
nmAgentPortsSFPASlotSlot numberro
Integer32
.1.3.6.1.4.1.3652.3.1.3.4.1.2
nmAgentPortsSFPAPortPort numberro
Integer32
.1.3.6.1.4.1.3652.3.1.3.4.1.3
nmAgentPortsSFPDMIRxLowWarningEventTransceiver RX power eventro
Enumeration
.1.3.6.1.4.1.3652.3.1.3.4.1.4
nmAgentPortsSFPDMIRxLowAlarmEventTransceiver RX power eventro
Enumeration
.1.3.6.1.4.1.3652.3.1.3.4.1.5
nmAgentPortsSFPDMITxPowerAlarmTransceiver TX power eventro
Enumeration
.1.3.6.1.4.1.3652.3.1.3.4.1.6
nmAgentPortsSFPDMIBiasAlarmEventTransceiver bias current eventro
Enumeration
.1.3.6.1.4.1.3652.3.1.3.4.1.7
nmAgentPortsSFPDMIRxHighAlarmEventTransceiver RX power eventro
Enumeration
.1.3.6.1.4.1.3652.3.1.3.4.1.8
nmAgentPortsSFPDWDMTECAlarmEventTransceiver DWDM TEC alarm eventro
Enumeration
.1.3.6.1.4.1.3652.3.1.3.4.1.9
nmAgentPortsSFPTempAlarmEventTransceiver temperature alarm eventro
Enumeration
.1.3.6.1.4.1.3652.3.1.3.4.1.10
nmCarrier
OBJECT IDENTIFIER
.1.3.6.1.4.1.3652.3.2
nmCarrierGerneralInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.3652.3.2.1
nmCarrierNamename or location of the SPEED-CARRIER system. Allowed characters are 0-9 a-z A-Z '-' and '_'ro
DisplayString
.1.3.6.1.4.1.3652.3.2.1.1
nmCarrierTypeType of SPEED-CARRIER system (1U / 4 slots, 4U or 4,5U with 17 slots)ro
Enumeration
.1.3.6.1.4.1.3652.3.2.1.2
nmPSU1StatusStatus of PSU 1ro
Enumeration
.1.3.6.1.4.1.3652.3.2.1.3
nmPSU2StatusStatus of PSU 2ro
Enumeration
.1.3.6.1.4.1.3652.3.2.1.4
nmFanStateFan state of the SPEED-CARRIER systemro
Enumeration
.1.3.6.1.4.1.3652.3.2.1.5
nmCarrierPSU1Typetype of PSU 1ro
Enumeration
.1.3.6.1.4.1.3652.3.2.1.6
nmCarrierPSU2Typetype of PSU 2ro
Enumeration
.1.3.6.1.4.1.3652.3.2.1.7
nmCarrierPSU1TextPSU 1 customer descriptionro
DisplayString
.1.3.6.1.4.1.3652.3.2.1.8
nmCarrierPSU2TextPSU 2 customer descriptionro
DisplayString
.1.3.6.1.4.1.3652.3.2.1.9
nmCarrierPSU3TextPSU 3 customer descriptionro
DisplayString
.1.3.6.1.4.1.3652.3.2.1.10
nmCarrierPSU3Typetype of PSU 3ro
Enumeration
.1.3.6.1.4.1.3652.3.2.1.11
nmPSU3StatusStatus of PSU 3ro
Enumeration
.1.3.6.1.4.1.3652.3.2.1.12
nmCarrierSerialNumberserial number of the SPEED-CARRIER system.ro
DisplayString
.1.3.6.1.4.1.3652.3.2.1.13
nmCarrierAssemblyAlarmOne or more Module Cards are expected but not installedro
Enumeration
.1.3.6.1.4.1.3652.3.2.1.14
nmCarrierSlotOverviewTableCarrier slot overview table
SEQUENCE OF NMCarrierSlotOverviewEntry
.1.3.6.1.4.1.3652.3.2.2
nmCarrierSlotOverviewEntryCarrier slot overview
NMCarrierSlotOverviewEntry
.1.3.6.1.4.1.3652.3.2.2.1
nmCarrierSlotNumberSlot Number 1..17 for 4,xU Carrier, 1..16 for 5U Carrier, 1..19 for 5U High Power Carrier or 1..4 for 1U Carrierro
Integer32
.1.3.6.1.4.1.3652.3.2.2.1.1
nmCarrierSlotTypeinstalled card type in this slotro
DisplayString
.1.3.6.1.4.1.3652.3.2.2.1.2
nmCarrierSlotPassiveTextuser defined text for passive cards. Is only available, if passive card is configuredro
DisplayString
.1.3.6.1.4.1.3652.3.2.2.1.3
nmFanOverviewTableFan overview table
SEQUENCE OF NMFanOverviewEntry
.1.3.6.1.4.1.3652.3.2.3
nmFanOverviewEntryFan overview table
NMFanOverviewEntry
.1.3.6.1.4.1.3652.3.2.3.1
nmFanGroupNumberFan group numberro
Integer32
.1.3.6.1.4.1.3652.3.2.3.1.1
nmFanGroupStatusFor 1U Carrier group1 is the front fan and group2 the rear fan For 4.5U Carrier: group 1 and 2 are PSU 1 and 2. group 3 is the front fan below the slots and group 4 the rear fans.ro
Enumeration
.1.3.6.1.4.1.3652.3.2.3.1.2
nmCarrierFWUpdate
OBJECT IDENTIFIER
.1.3.6.1.4.1.3652.3.2.4
nmCarrierFWUpdateFilenamefilename for copying to slotsrw
DisplayString
.1.3.6.1.4.1.3652.3.2.4.1
nmCarrierFirmwareTransferConfigControl and status of upload procedurerw
Enumeration
.1.3.6.1.4.1.3652.3.2.4.2
nmCarrierFWTransferProgresscopy progress in percentro
Integer32
.1.3.6.1.4.1.3652.3.2.4.3
nmCarrierFWUpdateConfigcopy and activates SW-images after next restartrw
Enumeration
.1.3.6.1.4.1.3652.3.2.4.4
nmCarrierFWUpdatePolicyTableupdate policy table
SEQUENCE OF NMCarrierFWUpdatePolicyEntry
.1.3.6.1.4.1.3652.3.2.5
nmCarrierFWUpdatePolicyEntryupdate policy
NMCarrierFWUpdatePolicyEntry
.1.3.6.1.4.1.3652.3.2.5.1
nmCarrierFWUpdatePolicySlotslot addressro
Integer32
.1.3.6.1.4.1.3652.3.2.5.1.1
nmCarrierFWUpdatePolicyCardNamecard namero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3652.3.2.5.1.2
nmCarrierFWUpdatePolicyConfigenable or disable updates for this slotrw
Enumeration
.1.3.6.1.4.1.3652.3.2.5.1.3
nmCarrierFWUpdatePolicyTransferStatefile transfer statero
Enumeration
.1.3.6.1.4.1.3652.3.2.5.1.4
nmCarrierConfigTransferTableupdate policy table
SEQUENCE OF NMCarrierConfigTransferEntry
.1.3.6.1.4.1.3652.3.2.6
nmCarrierConfigTransferEntryupdate policy
NMCarrierConfigTransferEntry
.1.3.6.1.4.1.3652.3.2.6.1
nmCarrierConfigSlotModule slot indexro
Integer32
.1.3.6.1.4.1.3652.3.2.6.1.1
nmCarrierConfigModuleNameModule namero
DisplayString
.1.3.6.1.4.1.3652.3.2.6.1.2
nmCarrierConfigTransferStateconfig statero
Enumeration
.1.3.6.1.4.1.3652.3.2.6.1.3
nmCarrierConfigTransferconfig command for transfering filesrw
Enumeration
.1.3.6.1.4.1.3652.3.2.6.1.4
nmCarrierConfigFilenameactual stored config file or filename to be sendrw
DisplayString
.1.3.6.1.4.1.3652.3.2.6.1.5
nmCarrierConfigActivationconfig file activation at slotrw
Enumeration
.1.3.6.1.4.1.3652.3.2.6.1.6
nmCarrierInventoryTableCarrier inventory table
SEQUENCE OF NMCarrierInventoryEntry
.1.3.6.1.4.1.3652.3.2.7
nmCarrierInventoryEntryCarrier inventory
NMCarrierInventoryEntry
.1.3.6.1.4.1.3652.3.2.7.1
nmCarrierInventoryIndexInventory Index
Integer32
.1.3.6.1.4.1.3652.3.2.7.1.1
nmCarrierInventorySlotNumberSlot Number 1..17 for 4,xU Carrier, 1..16 for 5U Carrier, 1..19 for 5U High Power Carrier or 1..4 for 1U Carrierro
Integer32
.1.3.6.1.4.1.3652.3.2.7.1.2
nmCarrierInventoryPortport number in this slotro
DisplayString
.1.3.6.1.4.1.3652.3.2.7.1.3
nmCarrierInventoryModuleNamename of the modulero
DisplayString
.1.3.6.1.4.1.3652.3.2.7.1.4
nmCarrierInventoryPartNumberpart numberro
DisplayString
.1.3.6.1.4.1.3652.3.2.7.1.5
nmCarrierInventorySerialNumberserial numberro
DisplayString
.1.3.6.1.4.1.3652.3.2.7.1.6
nmCarrierInventoryFirmwareReleasefirmware release of the modulero
DisplayString
.1.3.6.1.4.1.3652.3.2.7.1.7
nmCarrierInventoryKernelLoaderKernel/Loader version of the modulero
DisplayString
.1.3.6.1.4.1.3652.3.2.7.1.8
converter
OBJECT IDENTIFIER
.1.3.6.1.4.1.3652.3.3
convSPEEDDUALLINE
OBJECT IDENTIFIER
.1.3.6.1.4.1.3652.3.3.1
convSxLModuleOverviewTableSPEEDDUALLINE module overview table
SEQUENCE OF ConvSxLModuleOverviewEntry
.1.3.6.1.4.1.3652.3.3.1.1
convSxLModuleOverviewEntryModule overview entries
ConvSxLModuleOverviewEntry
.1.3.6.1.4.1.3652.3.3.1.1.1
convSxLMSlotSlot No. in Carrierro
Integer32
.1.3.6.1.4.1.3652.3.3.1.1.1.2
convSxLMDeviceModule DeviceTypero
Enumeration
.1.3.6.1.4.1.3652.3.3.1.1.1.3
convSxLMStatusStatus of inserted module. resetSoftware does not affect trafficrw
Enumeration
.1.3.6.1.4.1.3652.3.3.1.1.1.4
convSxLMSysUpTimeSystem uptime in secondsro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.3652.3.3.1.1.1.5
convSxLMTempModule temperaturero
Integer32
.1.3.6.1.4.1.3652.3.3.1.1.1.6
convSxLMAlarmStateModule alarm states, if they are active see Event-Tablero
Enumeration
.1.3.6.1.4.1.3652.3.3.1.1.1.7
convSxLMBootSWVersionModule bootloader software versionro
DisplayString
.1.3.6.1.4.1.3652.3.3.1.1.1.8
convSxLMAppSWVersionModule application software Versionro
DisplayString
.1.3.6.1.4.1.3652.3.3.1.1.1.9
convSxLMHWVersionModule board hardware versionro
DisplayString
.1.3.6.1.4.1.3652.3.3.1.1.1.10
convSxLMPLDVersionModule firmware versionro
DisplayString
.1.3.6.1.4.1.3652.3.3.1.1.1.11
convSxLMSerialNumberModules serial numberro
DisplayString
.1.3.6.1.4.1.3652.3.3.1.1.1.12
convSxLSWImagesOverviewTableSPEEDDUALLINE software images Overview Table
SEQUENCE OF ConvSxLSWImagesOverviewEntry
.1.3.6.1.4.1.3652.3.3.1.2
convSxLSWImagesOverviewEntryModule overview entries
ConvSxLSWImagesOverviewEntry
.1.3.6.1.4.1.3652.3.3.1.2.1
convSxLSWSlotSlot No. in Carrierro
Integer32
.1.3.6.1.4.1.3652.3.3.1.2.1.2
convSxLSWBootImageIdentification of bootimagero
DisplayString
.1.3.6.1.4.1.3652.3.3.1.2.1.3
convSxLSWAppImage1Identification of application image1ro
DisplayString
.1.3.6.1.4.1.3652.3.3.1.2.1.4
convSxLSWAppImage2Identification of application image2ro
DisplayString
.1.3.6.1.4.1.3652.3.3.1.2.1.5
convSxLSWUploadStatusControl and status of upload procedurero
Enumeration
.1.3.6.1.4.1.3652.3.3.1.2.1.6
convSxLSWUpdateStatusactivates SW-image after next resetro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.2.1.7
convSxLModuleConfigTableSPEEDDUALLINE config table
SEQUENCE OF ConvSxLModuleConfigEntry
.1.3.6.1.4.1.3652.3.3.1.3
convSxLModuleConfigEntryModule config entries
ConvSxLModuleConfigEntry
.1.3.6.1.4.1.3652.3.3.1.3.1
convSxLMCSlotSlot No. in Carrierro
Integer32
.1.3.6.1.4.1.3652.3.3.1.3.1.2
convSxLMIpAddressModule IP addressro
IpAddress
.1.3.6.1.4.1.3652.3.3.1.3.1.3
convSxLMIpNetmaskModule netmaskro
IpAddress
.1.3.6.1.4.1.3652.3.3.1.3.1.4
convSxLMIpGatewayDefault gatewayro
IpAddress
.1.3.6.1.4.1.3652.3.3.1.3.1.5
convSxLMIpTftpServerTFTP server address for SW-Updatero
IpAddress
.1.3.6.1.4.1.3652.3.3.1.3.1.6
convSxLMIpTrapSinkSNMP TrapSink-addressro
IpAddress
.1.3.6.1.4.1.3652.3.3.1.3.1.7
convSxLMSNMPReadCommunitySNMP ReadCommunityro
DisplayString
.1.3.6.1.4.1.3652.3.3.1.3.1.8
convSxLMSNMPWriteCommunitySNMP WriteCommunityro
DisplayString
.1.3.6.1.4.1.3652.3.3.1.3.1.9
convSxLMTempWarningLevelWarning level for module ambient temperature (0 - 60 degree Celsius)rw
Integer32
.1.3.6.1.4.1.3652.3.3.1.3.1.10
convSxLMTempAlarmLevelAlarm level for module ambient temperaturero
Integer32
.1.3.6.1.4.1.3652.3.3.1.3.1.11
convSxLMAlarmReportControls alarm signaling modes of modulero
Enumeration
.1.3.6.1.4.1.3652.3.3.1.3.1.12
convSxLMEthPortConfigModule Ethernet Port configrw
Enumeration
.1.3.6.1.4.1.3652.3.3.1.3.1.13
convSxLMEthPortStateModule Ethernet Port statero
Enumeration
.1.3.6.1.4.1.3652.3.3.1.3.1.14
convSxLMCliUserTimeoutModule CLI User Timeoutrw
Integer32
.1.3.6.1.4.1.3652.3.3.1.3.1.15
convSxLModuleProtectionTableSPEEDDUALLINE protection table
SEQUENCE OF ConvSxLModuleProtectionEntry
.1.3.6.1.4.1.3652.3.3.1.4
convSxLModuleProtectionEntryProtection table entries
ConvSxLModuleProtectionEntry
.1.3.6.1.4.1.3652.3.3.1.4.1
convSxLMPSlotSlot No. in Carrierro
Integer32
.1.3.6.1.4.1.3652.3.3.1.4.1.2
convSxLMLinkProtectionConfigStatus of protection modulerw
Enumeration
.1.3.6.1.4.1.3652.3.3.1.4.1.3
convSxLMLinkProtectionStatusStatus of protection functionality regarding the link port. The link port are always port1 (main) and port2 (backup). The local port is port4ro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.4.1.4
convSxLMLinkProtectionFallbackFallback time of errorfree seconds before switching back to MainPath. If there is an error during the Fallback-Time the timer will be restarted againrw
Integer32
.1.3.6.1.4.1.3652.3.3.1.4.1.5
convSxLPortOverviewTablePort status table
SEQUENCE OF ConvSxLPortOverviewEntry
.1.3.6.1.4.1.3652.3.3.1.5
convSxLPortOverviewEntryPort status entries
ConvSxLPortOverviewEntry
.1.3.6.1.4.1.3652.3.3.1.5.1
convSxLPortIndexPort Index
Integer32
.1.3.6.1.4.1.3652.3.3.1.5.1.1
convSxLSlotSlot numberro
Integer32
.1.3.6.1.4.1.3652.3.3.1.5.1.2
convSxLPortPort numberro
Integer32
.1.3.6.1.4.1.3652.3.3.1.5.1.3
convSxLDescriptionPort desription stringrw
DisplayString
.1.3.6.1.4.1.3652.3.3.1.5.1.4
convSxLAdminStatePort configuration modero
Enumeration
.1.3.6.1.4.1.3652.3.3.1.5.1.5
convSxLOperStatePort operational statero
Enumeration
.1.3.6.1.4.1.3652.3.3.1.5.1.6
convSxLSFPStateSFP-Port statero
Enumeration
.1.3.6.1.4.1.3652.3.3.1.5.1.7
convSxLLLCFStateStatus of linkloss configurationro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.5.1.8
convSxLLoopStateStatus of loop configurationro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.5.1.9
convSxLSpeedTxPort 3R regeneration speed and protocolro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.5.1.10
convSxLTxPortConnectionStatus of port to port connectionro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.5.1.11
convSxLAlarmStatePort warning / alarm statesro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.5.1.12
convSxLDMIStateAvailability or version of Diagnostic Monitoring Information (DMI)ro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.5.1.13
convSxLPortConfigTablePort config table
SEQUENCE OF ConvSxLPortConfigEntry
.1.3.6.1.4.1.3652.3.3.1.6
convSxLPortConfigEntryPort config entry
ConvSxLPortConfigEntry
.1.3.6.1.4.1.3652.3.3.1.6.1
convSxLCPortIndexPort Index
Integer32
.1.3.6.1.4.1.3652.3.3.1.6.1.1
convSxLCSlotSlot numberro
Integer32
.1.3.6.1.4.1.3652.3.3.1.6.1.2
convSxLCPortPort numberro
Integer32
.1.3.6.1.4.1.3652.3.3.1.6.1.3
convSxLAdminConfigAdmin configuration of a specific portrw
Enumeration
.1.3.6.1.4.1.3652.3.3.1.6.1.4
convSxLLLCFConfigConfiguration of Link Loss Carry Forward (LLCF) function. If a link down event occurs on the link port the local port will be disabled to signal the error state to the locally connected device e.g. routerrw
Enumeration
.1.3.6.1.4.1.3652.3.3.1.6.1.5
convSxLLoopConfigSetup of loops. After a reset, all loops will be switched offrw
Enumeration
.1.3.6.1.4.1.3652.3.3.1.6.1.6
convSxLSpeedConfigTxPort 3R regeneration speed and protocolrw
Enumeration
.1.3.6.1.4.1.3652.3.3.1.6.1.7
convSxLPortConnectionSetup of connections. toPortx means a connection between Rx-input to Tx-outputrw
Enumeration
.1.3.6.1.4.1.3652.3.3.1.6.1.8
convSxLPortAlarmDeactivationPort alarm deactivation schedulerw
Enumeration
.1.3.6.1.4.1.3652.3.3.1.6.1.9
convSxLPortAlarmSchedulePort alarm deactivation schedule. Value in hours. After this time has elapsed, the alarms are active again. Valid range: 1..1200. 0 means less then 1 hourrw
Integer32
.1.3.6.1.4.1.3652.3.3.1.6.1.10
convSxSFPIdentifikation
OBJECT IDENTIFIER
.1.3.6.1.4.1.3652.3.3.1.7
convSXLSFPDescriptionTableOptical transceiver parameter table
SEQUENCE OF ConvSXLSFPDescriptionEntry
.1.3.6.1.4.1.3652.3.3.1.7.1
convSXLSFPDescriptionEntryTalbe entries
ConvSXLSFPDescriptionEntry
.1.3.6.1.4.1.3652.3.3.1.7.1.1
convSxLSFPPortIndexPort Index
Integer32
.1.3.6.1.4.1.3652.3.3.1.7.1.1.1
convSxLSFPSlotSlot numberro
Integer32
.1.3.6.1.4.1.3652.3.3.1.7.1.1.2
convSxLSFPPortPort numberro
Integer32
.1.3.6.1.4.1.3652.3.3.1.7.1.1.3
convSxLSFPVendorSFP vendor namero
DisplayString
.1.3.6.1.4.1.3652.3.3.1.7.1.1.4
convSxLSFPVendorOUIVendor specific IEEE-OUIro
DisplayString
.1.3.6.1.4.1.3652.3.3.1.7.1.1.5
convSxLSFPVendorCodePart identification code, vendor specificro
DisplayString
.1.3.6.1.4.1.3652.3.3.1.7.1.1.6
convSxLSFPVendorRevisionCodeParts revision code, vendor specificro
DisplayString
.1.3.6.1.4.1.3652.3.3.1.7.1.1.7
convSxLSFPVendorDateCodeThe vendor date code for the transceiver. The date code is specified in the following format: YYYY.MM.DD/LL; YYYY = year; MM = month; DD = day of month; LL = vendor lot codero
DisplayString
.1.3.6.1.4.1.3652.3.3.1.7.1.1.8
convSxLSFPVendorSerialNumberParts serial numberro
DisplayString
.1.3.6.1.4.1.3652.3.3.1.7.1.1.9
convSxLSFPTypePhysical type of devicero
Enumeration
.1.3.6.1.4.1.3652.3.3.1.7.1.1.10
convSxLSFPConnectorThe connector value indicates the external connector provided on the interface.ro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.7.1.1.11
convSxLSFPWavelengthThe laser wavelength is the nominal transmitter output wavelength at room temperature. The value is in nanometers [nm]. This field allows the user to read the laser wavelength directly, so it is not necessary to infer it from the transceiver 'Code for Electronic Compatibility'.ro
DisplayString
.1.3.6.1.4.1.3652.3.3.1.7.1.1.12
convSxLSFPBitrateTableOptical transceiver bitrate table
SEQUENCE OF ConvSxLSFPBitrateEntry
.1.3.6.1.4.1.3652.3.3.1.7.2
convSxLSFPBitrateEntryTransceiver bitrate
ConvSxLSFPBitrateEntry
.1.3.6.1.4.1.3652.3.3.1.7.2.1
convSxLSFPBitratePortIndexPort Index
Integer32
.1.3.6.1.4.1.3652.3.3.1.7.2.1.1
convSxLSFPBitrateSlotSlot numberro
Integer32
.1.3.6.1.4.1.3652.3.3.1.7.2.1.2
convSxLSFPBitratePortPort numberro
Integer32
.1.3.6.1.4.1.3652.3.3.1.7.2.1.3
convSxLSFPBitrateNominalThe nominal bit rate is specified in units of 1 Megabit per second, rounded up to the next 100 Megabits per second. The bit rate includes those bits necessary to encode and delimit the signal as well as those bits carrying data information. A value of 0 indicates that the bit rate is not specified and must be determined from the transceiver technology. The actual information transfer rate will depend on the data encoding defined by the encoding value.ro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.7.2.1.4
convSxLSFPBitrateMaxThe upper bit rate limit at which the SFP transceiver will still meet its specifications is specified in units of 1 Megabit per second. A value of 0 indicates that this field is not specified.ro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.7.2.1.5
convSxLSFPBitrateMinThe lower bit rate limit at which the SFP transceiver will still meet its specifications is specified in units of 1 Megabit per second. A value of 0 indicates that this field is not specified.ro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.7.2.1.6
convSxLSFPLengthTableOptical Transceiver Length Table
SEQUENCE OF ConvSxLSFPLengthEntry
.1.3.6.1.4.1.3652.3.3.1.7.3
convSxLSFPLengthEntryOptical Transceiver Length Coding Entries
ConvSxLSFPLengthEntry
.1.3.6.1.4.1.3652.3.3.1.7.3.1
convSxLSFPLengthPortIndexPort Index
Integer32
.1.3.6.1.4.1.3652.3.3.1.7.3.1.1
convSxLSFPLengthSlotSlot numberro
Integer32
.1.3.6.1.4.1.3652.3.3.1.7.3.1.2
convSxLSFPLengthPortPort numberro
Integer32
.1.3.6.1.4.1.3652.3.3.1.7.3.1.3
convSxLSFPLength9kmThis value specifies the link length that is supported by the SFP transceiver while operating in compliance with the applicable standards using single mode fiber. The value is in units of kilometers. A value of 255 means that the transceiver supports a link greater than 254 km. A value of 0 means that the transceiver does not support single mode fiber or that the length information must be determined from the transceiver technology.ro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.7.3.1.4
convSxLSFPLength9mThis value specifies the link length that is supported by the SFP transceiver while operating in compliance with the applicable standards using single mode fiber. The value is in units of 100 meters. A value of 255 means that the transceiver supports a link greater than 25.4 km. A value of 0 means that the transceiver does not support single mode fiber or that the length information must be determined from the transceiver technology.ro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.7.3.1.5
convSxLSFPLength50This value specifies the link length that is supported by the SFP transceiver while operating in compliance with the applicable standards using 50 micron multi mode fiber. The value is in units of 10 meters. A value of 255 means that the transceiver supports a link greater than 2.54 km. A value of 0 means that the transceiver does not support 50 micron multi mode fiber or that the length information must be determined from the transceiver technology.ro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.7.3.1.6
convSxLSFPLength62This value specifies the link length that is supported by the SFP transceiver while operating in compliance with the applicable standards using 62.5 micron multi mode fiber. The value is in units of 10 meters. A value of 255 means that the transceiver supports a link greater than 2.54 km. A value of 0 means that the transceiver does not support 62.5 micron multi mode fiber or that the length information must be determined from the transceiver technology.ro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.7.3.1.7
convSxLSFPLengthCopperThis value specifies the link length that is supported by the SFP transceiver while operating in compliance with the applicable standards using copper cable. The value is in units of 1 meter. A value of 255 means that the transceiver supports a link greater than 254 m. A value of 0 means that the transceiver does not support copper cable or that the length information must be determined from the transceiver technology. Further information about the cable design, equalization, and connectors is usually required to guarantee meeting of particular length information.ro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.7.3.1.8
convSxLSFPCompCodes
OBJECT IDENTIFIER
.1.3.6.1.4.1.3652.3.3.1.7.4
convSxLSFPCompCodeSonetTableOptical transceiver sonet compatibility table
SEQUENCE OF ConvSxLSFPCompCodeSonetEntry
.1.3.6.1.4.1.3652.3.3.1.7.4.1
convSxLSFPCompCodeSonetEntryTransceiver compatibility code entries
ConvSxLSFPCompCodeSonetEntry
.1.3.6.1.4.1.3652.3.3.1.7.4.1.1
convSxLSFPCSPortIndexPort Index
Integer32
.1.3.6.1.4.1.3652.3.3.1.7.4.1.1.1
convSxLSFPCSSlotSlot numberro
Integer32
.1.3.6.1.4.1.3652.3.3.1.7.4.1.1.2
convSxLSFPCSPortPort numberro
Integer32
.1.3.6.1.4.1.3652.3.3.1.7.4.1.1.3
convSxLSFPCSProtocolSupported protocolro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.7.4.1.1.4
convSxLSFPCSRangeOptical transceivers rangero
Enumeration
.1.3.6.1.4.1.3652.3.3.1.7.4.1.1.5
convSxLSFPCSFiberTypeSupported fiber typero
Enumeration
.1.3.6.1.4.1.3652.3.3.1.7.4.1.1.6
convSxLSFPCompCodeGigabitEthernetTableOptical transceiver gigabit Ethernet compatibility table
SEQUENCE OF ConvSxLSFPCompCodeGigabitEthernetEntry
.1.3.6.1.4.1.3652.3.3.1.7.4.2
convSxLSFPCompCodeGigabitEthernetEntryTable entries
ConvSxLSFPCompCodeGigabitEthernetEntry
.1.3.6.1.4.1.3652.3.3.1.7.4.2.1
convSxLSFPCGPortIndexPort Index
Integer32
.1.3.6.1.4.1.3652.3.3.1.7.4.2.1.1
convSxLSFPCGSlotSlot numberro
Integer32
.1.3.6.1.4.1.3652.3.3.1.7.4.2.1.2
convSxLSFPCGPortPort numberro
Integer32
.1.3.6.1.4.1.3652.3.3.1.7.4.2.1.3
convSxLSFPCGTypeSupported protocolro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.7.4.2.1.4
convSxLSFPCompCodeFibreChannelTableOptical transceiver fibre channel compatibility table
SEQUENCE OF ConvSxLSFPCompCodeFibreChannelEntry
.1.3.6.1.4.1.3652.3.3.1.7.4.3
convSxLSFPCompCodeFibreChannelEntryTable entries
ConvSxLSFPCompCodeFibreChannelEntry
.1.3.6.1.4.1.3652.3.3.1.7.4.3.1
convSxLSFPCFcPortIndexPort Index
Integer32
.1.3.6.1.4.1.3652.3.3.1.7.4.3.1.1
convSxLSFPCFcSlotSlot numberro
Integer32
.1.3.6.1.4.1.3652.3.3.1.7.4.3.1.2
convSxLSFPCFcPortPort numberro
Integer32
.1.3.6.1.4.1.3652.3.3.1.7.4.3.1.3
convSxLSFPCFcMediaSupported media typesro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.7.4.3.1.4
convSxLSFPCFcTechTransmitter technologyro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.7.4.3.1.5
convSxLSFPCFcLinkLengthLink length supported by transceiverro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.7.4.3.1.6
convSxLSFPCFcSpeedFibre channel speedro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.7.4.3.1.7
convSxLCopperSFPTableOverview and configuration of copper SFP table
SEQUENCE OF ConvSxLCopperSFPEntry
.1.3.6.1.4.1.3652.3.3.1.7.5
convSxLCopperSFPEntryTransceiver overview and configuration entries
ConvSxLCopperSFPEntry
.1.3.6.1.4.1.3652.3.3.1.7.5.1
convSxLCuSFPPortIndexPort Index
Integer32
.1.3.6.1.4.1.3652.3.3.1.7.5.1.1
convSxLCuSFPSlotSlot numberro
Integer32
.1.3.6.1.4.1.3652.3.3.1.7.5.1.2
convSxLCuSFPPortPort numberro
Integer32
.1.3.6.1.4.1.3652.3.3.1.7.5.1.3
convSxLConfigSpeedUser defined configuration of speedrw
Enumeration
.1.3.6.1.4.1.3652.3.3.1.7.5.1.4
convSxLConfigDuplexUser defined configuration of duplex moderw
Enumeration
.1.3.6.1.4.1.3652.3.3.1.7.5.1.5
convSxLCuPhyIdPhysical transceiver installed in SFP, if unkown the transceiver is not supportedro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.7.5.1.6
convSxLCuSFPSpeedactual speed status of internal physical in copper SFPro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.7.5.1.8
convSxLCuSFPDuplexactual duplex mode status of internal physical in copper SFPro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.7.5.1.9
convSxLCuSFPAutoMDIxactual of status MDI-connection in copper SFPrw
Enumeration
.1.3.6.1.4.1.3652.3.3.1.7.5.1.10
convSxLCuSFPConfigModeactual config mode in copper SFPrw
Enumeration
.1.3.6.1.4.1.3652.3.3.1.7.5.1.11
convSxLDWDMSFPTableOverview and configuration of DWDM SFP table
SEQUENCE OF ConvSxLDWDMSFPEntry
.1.3.6.1.4.1.3652.3.3.1.7.6
convSxLDWDMSFPEntryTransceiver overview and configuration entries
ConvSxLDWDMSFPEntry
.1.3.6.1.4.1.3652.3.3.1.7.6.1
convSxLDWDMPortIndexPort Index
Integer32
.1.3.6.1.4.1.3652.3.3.1.7.6.1.1
convSxLDWDMSlotSlot numberro
Integer32
.1.3.6.1.4.1.3652.3.3.1.7.6.1.2
convSxLDWDMPortPort numberro
Integer32
.1.3.6.1.4.1.3652.3.3.1.7.6.1.3
convSxLDWDMPowerClassPower class of installed DWDM-SFPro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.7.6.1.4
convSxLDWDMMaxSupplyCurrentDefines the maximum supply current the module will consume under worst conditions in units of 4mAro
Integer32
.1.3.6.1.4.1.3652.3.3.1.7.6.1.5
convSxLChannelSpacingIdentifies the densest channel spacing the module is compatible withro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.7.6.1.6
convSxLNumberofChannelsIdentifies the number of channels over which the module may be tuned by user command. If not tunable the number is 1ro
Integer32
.1.3.6.1.4.1.3652.3.3.1.7.6.1.7
convSxLSFPDMIParamTableOptical transceiver measurement parameter table
SEQUENCE OF ConvSxLSFPDMIParamEntry
.1.3.6.1.4.1.3652.3.3.1.8
convSxLSFPDMIParamEntryTable entries
ConvSxLSFPDMIParamEntry
.1.3.6.1.4.1.3652.3.3.1.8.1
convSxLSFPDMIPortIndexPort Indexro
Integer32
.1.3.6.1.4.1.3652.3.3.1.8.1.1
convSxLSFPDMISlotSlot numberro
Integer32
.1.3.6.1.4.1.3652.3.3.1.8.1.2
convSxLSFPDMIPortPort numberro
Integer32
.1.3.6.1.4.1.3652.3.3.1.8.1.3
convSxLSFPDMIRxLevelOptical receive powerro
Integer32
.1.3.6.1.4.1.3652.3.3.1.8.1.4
convSxLSFPDMIRxHighAlarmStatus of receive optical power, active when overloadedro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.8.1.5
convSxLSFPDMITxLevelOptical transmit powerro
Integer32
.1.3.6.1.4.1.3652.3.3.1.8.1.6
convSxLSFPDMITxBiasTransceiver hardware parameter: laser bias currentro
Integer32
.1.3.6.1.4.1.3652.3.3.1.8.1.7
convSxLSFPDMIVccTransceiver hardware parameter: supply voltagero
Integer32
.1.3.6.1.4.1.3652.3.3.1.8.1.8
convSxLSFPDMITempTransceiver hardware parameter: temperature valuero
Integer32
.1.3.6.1.4.1.3652.3.3.1.8.1.9
convSxLSFPDMIThresholdTableOptical transceiver measurement threshold table
SEQUENCE OF ConvSxLSFPDMIThresholdEntry
.1.3.6.1.4.1.3652.3.3.1.9
convSxLSFPDMIThresholdEntryMeasurement parameter overview
ConvSxLSFPDMIThresholdEntry
.1.3.6.1.4.1.3652.3.3.1.9.1
convSxLSFPDMITPortIndexPort Index
Integer32
.1.3.6.1.4.1.3652.3.3.1.9.1.1
convSxLSFPDMITSlotSlot numberro
Integer32
.1.3.6.1.4.1.3652.3.3.1.9.1.2
convSxLSFPDMITPortPort numberro
Integer32
.1.3.6.1.4.1.3652.3.3.1.9.1.3
convSxLSFPDMITRxLowThresholdWarningLevelOptical receive power warning level. Value display and set is dBm/100rw
Integer32
.1.3.6.1.4.1.3652.3.3.1.9.1.4
convSxLSFPDMITRxLowThresholdAlarmLevelOptical receive power alarm level. Value display is dBm/100ro
Integer32
.1.3.6.1.4.1.3652.3.3.1.9.1.5
convSxLSFPDMITTxLowThresholdWarningLevelOptical transmit power warning level. Value display and set is dBm/100rw
Integer32
.1.3.6.1.4.1.3652.3.3.1.9.1.6
convSxLSFPDMITTxLowThresholdAlarmLevelOptical transmit power alarm level. Value display is dBm/100ro
Integer32
.1.3.6.1.4.1.3652.3.3.1.9.1.7
convSxLSFPDMITThresholdsUsageSet threshold usage. Activate user defined or vendor defined thresholdsrw
Enumeration
.1.3.6.1.4.1.3652.3.3.1.9.1.8
convSxLPortEventTablePort event Table
SEQUENCE OF ConvSxLPortEventEntry
.1.3.6.1.4.1.3652.3.3.1.10
convSxLPortEventEntryPort event table entries
ConvSxLPortEventEntry
.1.3.6.1.4.1.3652.3.3.1.10.1
convSxLSFPEPortIndexPort Index
Integer32
.1.3.6.1.4.1.3652.3.3.1.10.1.1
convSxLSFPESlotSlot numberro
Integer32
.1.3.6.1.4.1.3652.3.3.1.10.1.2
convSxLSFPEPortPort numberro
Integer32
.1.3.6.1.4.1.3652.3.3.1.10.1.3
convSxLSFPDMIRxLowWarningEventReceive power - low warningro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.10.1.4
convSxLSFPDMIRxLowAlarmEventReceive power - low alarmro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.10.1.5
convSxLSFPDMITxLowWarningEventOutput power - low warningro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.10.1.6
convSxLSFPDMITxLowAlarmEventOutput power - low alarmro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.10.1.7
convSxLSFPDMIBiasAlarmEventTransmitter bias current is lowro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.10.1.8
convSxLSFPDMIRxHighAlarmEventReceiver input power is highro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.10.1.9
convSxLSFPDWDMLaserTHighAlarmEventSet when laser temperature or wavelength exceeds high alarm level.ro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.10.1.10
convSxLSFPDWDMLaserTLowAlarmEventSet when laser temperature or wavelength exceeds low alarm level.ro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.10.1.11
convSxLSFPDWDMTECHighAlarmEventSet when TEC current exceeds high alarm level (cooling problem)ro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.10.1.12
convSxLSFPDWDMTECLowAlarmEventSet when TEC current exceeds low alarm level (heating problem)ro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.10.1.13
convSxLSFPDMITempHighWarningEventTransceiver DMI temperature high warning eventro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.10.1.14
convSxLSFPDMITempHighAlarmEventTransceiver DMI temperature high alarm eventro
Enumeration
.1.3.6.1.4.1.3652.3.3.1.10.1.15
convSxLInventoryTableTable of all serial numbers installed in module
SEQUENCE OF ConvSxLInventoryEntry
.1.3.6.1.4.1.3652.3.3.1.11
convSxLInventoryEntryTable entries
ConvSxLInventoryEntry
.1.3.6.1.4.1.3652.3.3.1.11.1
convSxLInvSlotSlot No. in Carrierro
Integer32
.1.3.6.1.4.1.3652.3.3.1.11.1.2
convSxLModuleSerialNumberSerial number of modulero
DisplayString
.1.3.6.1.4.1.3652.3.3.1.11.1.3
convSxLSFPPort1SerialNumberSerial number of installed transceiverro
DisplayString
.1.3.6.1.4.1.3652.3.3.1.11.1.4
convSxLSFPPort2SerialNumberSerial number of installed transceiverro
DisplayString
.1.3.6.1.4.1.3652.3.3.1.11.1.5
convSxLSFPPort3SerialNumberSerial number of installed transceiverro
DisplayString
.1.3.6.1.4.1.3652.3.3.1.11.1.6
convSxLSFPPort4SerialNumberSerial number of installed transceiverro
DisplayString
.1.3.6.1.4.1.3652.3.3.1.11.1.7
multiplexer
OBJECT IDENTIFIER
.1.3.6.1.4.1.3652.3.4
amplifier
OBJECT IDENTIFIER
.1.3.6.1.4.1.3652.3.5