SPEEDCARRIER-MIB
AI MIB Summary
The SPEEDCARRIER-MIB provides SNMP management access to Speed Carrier hardware and its associated management cards, exposing operational status, interface statistics, and device health metrics for telecommunications carrier equipment.
This MIB module defines objects for the SPEED CARRIER and the management card
Main OID:
nmSPEEDCARRIER.1.3.6.1.4.1.3652.3
413
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
413 total| Object Name |
|---|
coldStartColdStart NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.40 |
rebootReboot NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.41 |
fanErrorFANError NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.42 |
fanOKFANOK NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.43 |
powerFailurePowerFailure NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.44 |
powerOKPowerOK NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.45 |
highTempHighTemp NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.46 |
tempOKTempOK NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.47 |
transceiverRemovedSFPRemoved NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.48 |
transceiverInsertedSFPInserted NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.49 |
moduleInsertedModuleInserted NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.50 |
moduleRemovedModuleRemoved NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.51 |
portTxUpPortTxUp NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.52 |
portTxDownPortTxDown NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.53 |
portUpPortUp NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.54 |
portDownPortDown NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.55 |
txFaultTxFault NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.56 |
badPasswdBadPasswd NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.57 |
softwareUpdateReadySoftwareUpdateReady NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.58 |
hardwareTrapHardwareTrap NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.59 |
cdrAlarmCDRAlarm NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.60 |
protectionMainProtectionMain NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.61 |
protectionBackupProtectionBackup NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.62 |
optRxLevelWarningOptRxLevelWarning NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.63 |
optRxLevelAlarmOptRxLevelAlarm NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.64 |
optRxLevelOKOptRxLevelOK NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.65 |
optTxLevelWarningOptTxLevelWarning NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.66 |
optTxLevelAlarmOptTxLevelAlarm NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.67 |
optTxLevelOKOptTxLevelOK NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.68 |
optTxBiasAlarmTX Bias Alarm NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.69 |
optTxBiasOKTX Bias OK NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.70 |
optRxPowerOverloadHigh optical input power Alarm NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.71 |
configErrorConfiguration error. An set command or config file transfer was not successful. NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.72 |
configurationConfiguration file information NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.73 |
maintenanceMaintennance Change NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.74 |
ampFailAMP error is occured NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.75 |
ampOkAMP error is cleared NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.76 |
dwdmAlarmDWDM transceiver alarm occured NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.77 |
dwdmOkDWDM transceiver alarm cleared NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.78 |
firmwareErrorfirmware or kernel transfer or flashing error NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.79 |
tuningErrortransceiver tuning error NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.80 |
encryptionencryption error NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.81 |
emergencyShutdownCarrier Emergency Shutdown NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.82 |
unspecifiedUnspecified NOTIFICATION-TYPE .1.3.6.1.4.1.3652.0.255 |
nmSPEEDCARRIERThis MIB module defines objects for the SPEED CARRIER and the management card MODULE-IDENTITY .1.3.6.1.4.1.3652.3 |
nmAgent OBJECT IDENTIFIER .1.3.6.1.4.1.3652.3.1 |
nmAgentGeneralInfo OBJECT IDENTIFIER .1.3.6.1.4.1.3652.3.1.1 |
nmARamdiskVersionSPEED-NMS Ramdisk Versionro DisplayString .1.3.6.1.4.1.3652.3.1.1.1 |
nmASlotSlot in which the SPEED-NMS card is insertedro Integer32 .1.3.6.1.4.1.3652.3.1.1.2 |
nmADateDate of the SPEED-NMS systemro DisplayString .1.3.6.1.4.1.3652.3.1.1.3 |
nmATimeActual Time of the SPEED-NMS systemro DisplayString .1.3.6.1.4.1.3652.3.1.1.4 |
nmAUpTimeSystem uptime of the SPEED-NMS systemro DisplayString .1.3.6.1.4.1.3652.3.1.1.5 |
nmATemperatureBoard temperature of the SPEED-NMS systemro Integer32 .1.3.6.1.4.1.3652.3.1.1.6 |
nmAAlarmStateAlarm state of the SPEED-NMS systemro Enumeration .1.3.6.1.4.1.3652.3.1.1.7 |
nmASerialNumberSerial number of the SPEED-NMS systemro DisplayString .1.3.6.1.4.1.3652.3.1.1.8 |
nmAKernelVersionSPEED-NMS Kernel Versionro DisplayString .1.3.6.1.4.1.3652.3.1.1.9 |
nmASoftwareVersionSPEED-NMS Software Versionro DisplayString .1.3.6.1.4.1.3652.3.1.1.10 |
nmAgentConfig OBJECT IDENTIFIER .1.3.6.1.4.1.3652.3.1.2 |
nmAgentConfigNetwork OBJECT IDENTIFIER .1.3.6.1.4.1.3652.3.1.2.1 |
nmAgentConfigNetworkIPIP-address of the management boards Ethernet interfacerw IpAddress .1.3.6.1.4.1.3652.3.1.2.1.1 |
nmAgentConfigNetworkMaskIP-netmask of the management boards Ethernet interfacerw IpAddress .1.3.6.1.4.1.3652.3.1.2.1.2 |
nmAgentConfigNetworkGatewaydefault gateway of the management boards Ethernet interfacerw IpAddress .1.3.6.1.4.1.3652.3.1.2.1.3 |
nmAgentConfigNetworkIPv6IPv6-address of the management boards Ethernet interfacerw DisplayString .1.3.6.1.4.1.3652.3.1.2.1.5 |
nmAgentConfigNetworkGatewayv6default gatewayv6 of the management boards Ethernet interfacerw DisplayString .1.3.6.1.4.1.3652.3.1.2.1.6 |
nmAgentConfigSnmp OBJECT IDENTIFIER .1.3.6.1.4.1.3652.3.1.2.2 |
nmAgentConfigSnmpReadCommunitySNMP read community namerw DisplayString .1.3.6.1.4.1.3652.3.1.2.2.1 |
nmAgentConfigSnmpWriteCommunitySNMP write community namerw DisplayString .1.3.6.1.4.1.3652.3.1.2.2.2 |
nmAgentConfigSnmpSysLocationlocation of the SPEED-CARRIER systemrw DisplayString .1.3.6.1.4.1.3652.3.1.2.2.3 |
nmAgentConfigSnmpSysContactadministrator of the SPEED-CARRIER systemrw DisplayString .1.3.6.1.4.1.3652.3.1.2.2.4 |
nmAgentConfigSnmpTrapSink1Trap destination 1 for SNMP traps. Clear value is 0.0.0.0rw DisplayString .1.3.6.1.4.1.3652.3.1.2.2.5 |
nmAgentConfigSnmpTrapSink2Trap destination 2 for SNMP traps. Clear value is 0.0.0.0rw DisplayString .1.3.6.1.4.1.3652.3.1.2.2.6 |
nmAgentConfigSnmpTrapSink3Trap destination 3 for SNMP traps. Clear value is 0.0.0.0rw DisplayString .1.3.6.1.4.1.3652.3.1.2.2.7 |
nmAgentConfigSnmpTrapSink4Trap destination 4 for SNMP traps. Clear value is 0.0.0.0rw DisplayString .1.3.6.1.4.1.3652.3.1.2.2.8 |
nmAgentConfigSnmpTrapSink5Trap destination 5 for SNMP traps. Clear value is 0.0.0.0rw DisplayString .1.3.6.1.4.1.3652.3.1.2.2.9 |
nmAgentConfigSnmpAgentenable or disable the SNMP agent on the management boardrw Enumeration .1.3.6.1.4.1.3652.3.1.2.2.10 |
nmAgentConfigSNMPv3UserConfigTableSNMPv3 user configuration table SEQUENCE OF NMAgentConfigSNMPv3UserConfigEntry .1.3.6.1.4.1.3652.3.1.2.2.11 |
nmAgentConfigSNMPv3UserConfigEntrySNMPv3 user configuration table NMAgentConfigSNMPv3UserConfigEntry .1.3.6.1.4.1.3652.3.1.2.2.11.1 |
nmAgentConfigSNMPv3UserConfigIndexuser indexro Integer32 .1.3.6.1.4.1.3652.3.1.2.2.11.1.1 |
nmAgentConfigSnmpv3UserConfigNameuser namerw DisplayString .1.3.6.1.4.1.3652.3.1.2.2.11.1.2 |
nmAgentConfigSnmpv3UserConfigUserLeveluser rights read-only (ro) or read-write (rw)rw Enumeration .1.3.6.1.4.1.3652.3.1.2.2.11.1.3 |
nmAgentConfigSnmpv3UserConfigAuthTypeauthentication typesrw Enumeration .1.3.6.1.4.1.3652.3.1.2.2.11.1.4 |
nmAgentConfigSnmpv3UserConfigAuthPassPhraseauthentication passphraserw DisplayString .1.3.6.1.4.1.3652.3.1.2.2.11.1.5 |
nmAgentConfigSnmpv3UserConfigEncTypeprivacy protocolsrw Enumeration .1.3.6.1.4.1.3652.3.1.2.2.11.1.6 |
nmAgentConfigSnmpv3UserConfigPrivPassPhraseprivacy passphraserw DisplayString .1.3.6.1.4.1.3652.3.1.2.2.11.1.7 |
nmAgentConfigSlotAlarmsTableTable for Slot 'alarm relay' configuration SEQUENCE OF NMAgentConfigSlotAlarmsEntry .1.3.6.1.4.1.3652.3.1.2.3 |
nmAgentConfigSlotAlarmsEntryactivate or deactivate slot for 'alarm relay' configuration NMAgentConfigSlotAlarmsEntry .1.3.6.1.4.1.3652.3.1.2.3.1 |
nmAgentConfigSlotAlarmsSlotNumberSlot number for alarm relay configurationro Integer32 .1.3.6.1.4.1.3652.3.1.2.3.1.1 |
nmAgentConfigSlotAlarmsInsertedCardCard type of inserted card in this slotro DisplayString .1.3.6.1.4.1.3652.3.1.2.3.1.2 |
nmAgentConfigSlotAlarmsConfigset alarm reporting to 'on' or 'off' for this slotrw Enumeration .1.3.6.1.4.1.3652.3.1.2.3.1.3 |
nmAgentConfigSlotModulesTableTable for card configuration SEQUENCE OF NMAgentConfigSlotModulesEntry .1.3.6.1.4.1.3652.3.1.2.4 |
nmAgentConfigSlotModulesEntryTable for card configuration NMAgentConfigSlotModulesEntry .1.3.6.1.4.1.3652.3.1.2.4.1 |
nmAgentConfigModulesSlotNumberslot number for card configurationro Integer32 .1.3.6.1.4.1.3652.3.1.2.4.1.1 |
nmAgentConfigModulesInstalledCardCard type of inserted card in this slotro DisplayString .1.3.6.1.4.1.3652.3.1.2.4.1.2 |
nmAgentConfigModulesExpectedCardset the type of card, which is inserted in slotrw Enumeration .1.3.6.1.4.1.3652.3.1.2.4.1.3 |
nmAgentConfigModulesSlotTextset the user defined text for passive card, which is inserted in slotrw DisplayString .1.3.6.1.4.1.3652.3.1.2.4.1.4 |
nmAgentConfigModulesInstalledStateCheck the installed module against the expected modulero DisplayString .1.3.6.1.4.1.3652.3.1.2.4.1.5 |
nmAgentConfigAlarmRelayconfigure alarm relay for different sourcesrw Enumeration .1.3.6.1.4.1.3652.3.1.2.7 |
nmAgentConfigFANconfigure fans to 'allOn' or 'auto'rw Enumeration .1.3.6.1.4.1.3652.3.1.2.8 |
nmAgentConfigNtpServerIP address of the Network Time Protocol server. Clear value is '0.0.0.0'.rw DisplayString .1.3.6.1.4.1.3652.3.1.2.9 |
nmAgentConfigTftpServerenable or disable the TFTP server on the management boardrw Enumeration .1.3.6.1.4.1.3652.3.1.2.10 |
nmAgentConfigWebServerenable or disable the web server on the management boardrw Enumeration .1.3.6.1.4.1.3652.3.1.2.11 |
nmAgentConfigMyWebViewconfigures the start screen of WebView for the web interfacerw Enumeration .1.3.6.1.4.1.3652.3.1.2.12 |
nmAgentConfigTimezonesets the system time zone. Has only effect after rebootrw Enumeration .1.3.6.1.4.1.3652.3.1.2.15 |
nmAgentConfigAccesssets system access to telnet, SSH version 2 or offrw Enumeration .1.3.6.1.4.1.3652.3.1.2.16 |
nmAgentConfigCliTimeouttime without user interaction before exiting CLI. Valid range 120-3600 seconds.rw Integer32 .1.3.6.1.4.1.3652.3.1.2.17 |
nmAgentConfigRadiusStateConfiglocal or radius, local authenticationrw Enumeration .1.3.6.1.4.1.3652.3.1.2.19 |
nmAgentConfigNMSStaterunning state of NMS module. Reboot is NOT traffic effecting!rw Enumeration .1.3.6.1.4.1.3652.3.1.2.21 |
nmAgentConfigRadiusServerConfigTableRADIUS server configuration table SEQUENCE OF NMAgentConfigRadiusServerConfigEntry .1.3.6.1.4.1.3652.3.1.2.26 |
nmAgentConfigRadiusServerConfigEntryRADIUS server configuration table NMAgentConfigRadiusServerConfigEntry .1.3.6.1.4.1.3652.3.1.2.26.1 |
nmAgentConfigRadiusServerConfigNumberRADIUS server numberro Integer32 .1.3.6.1.4.1.3652.3.1.2.26.1.1 |
nmAgentConfigRadiusServerConfigIPAddressRADIUS server IPv4 or IPv6 addressrw DisplayString .1.3.6.1.4.1.3652.3.1.2.26.1.2 |
nmAgentConfigRadiusServerConfigSharedSecretRADIUS server shared secretrw DisplayString .1.3.6.1.4.1.3652.3.1.2.26.1.3 |
nmAgentConfigSyslogServerIPAddressSyslog server IPv4 or IPv6 addressrw DisplayString .1.3.6.1.4.1.3652.3.1.2.27 |
nmAgentConfigSyslogSeverityconfigures the syslog severityrw Enumeration .1.3.6.1.4.1.3652.3.1.2.28 |
nmAgentConfigSyslogFacilityconfigures the syslog facilityrw Enumeration .1.3.6.1.4.1.3652.3.1.2.29 |
nmAgentPorts OBJECT IDENTIFIER .1.3.6.1.4.1.3652.3.1.3 |
nmAgentPortsPortOverviewTablePort overview table SEQUENCE OF NmAgentPortsPortOverviewEntry .1.3.6.1.4.1.3652.3.1.3.1 |
nmAgentPortsPortOverviewEntryPort overview entries NmAgentPortsPortOverviewEntry .1.3.6.1.4.1.3652.3.1.3.1.1 |
nmAgentPortsIndexIndex Integer32 .1.3.6.1.4.1.3652.3.1.3.1.1.1 |
nmAgentPortsSlotSlot numberro Integer32 .1.3.6.1.4.1.3652.3.1.3.1.1.2 |
nmAgentPortsPortPort numberro Integer32 .1.3.6.1.4.1.3652.3.1.3.1.1.3 |
nmAgentPortsAdminConfigPort admin configrw Enumeration .1.3.6.1.4.1.3652.3.1.3.1.1.4 |
nmAgentPortsOperStateSFPSFP Ports operational statero Enumeration .1.3.6.1.4.1.3652.3.1.3.1.1.5 |
nmAgentPortsAlarmStatePort alarm statero Enumeration .1.3.6.1.4.1.3652.3.1.3.1.1.6 |
nmAgentPortsPortTypePort typero DisplayString .1.3.6.1.4.1.3652.3.1.3.1.1.7 |
nmAgentPortsPortDescriptionPort descriptionrw DisplayString .1.3.6.1.4.1.3652.3.1.3.1.1.8 |
nmAgentPortsOperStateCopperCopper Ports operational statero Enumeration .1.3.6.1.4.1.3652.3.1.3.1.1.9 |
nmAgentPortsSFPOverviewTableSFP overview table SEQUENCE OF NmAgentPortsSFPOverviewEntry .1.3.6.1.4.1.3652.3.1.3.2 |
nmAgentPortsSFPOverviewEntryModule transceiver overview entries NmAgentPortsSFPOverviewEntry .1.3.6.1.4.1.3652.3.1.3.2.1 |
nmAgentPortsSFPIndexIndex Integer32 .1.3.6.1.4.1.3652.3.1.3.2.1.1 |
nmAgentPortsSFPSlotSlot numberro Integer32 .1.3.6.1.4.1.3652.3.1.3.2.1.2 |
nmAgentPortsSFPPortPort numberro Integer32 .1.3.6.1.4.1.3652.3.1.3.2.1.3 |
nmAgentPortsSFPStateSFP statero Enumeration .1.3.6.1.4.1.3652.3.1.3.2.1.4 |
nmAgentPortsDMIStateDMI statero Integer32 .1.3.6.1.4.1.3652.3.1.3.2.1.5 |
nmAgentPortsVendorNameTransceiver vendor namero DisplayString .1.3.6.1.4.1.3652.3.1.3.2.1.6 |
nmAgentPortsVendorPartNumberTransceiver part numberro DisplayString .1.3.6.1.4.1.3652.3.1.3.2.1.7 |
nmAgentPortsVendorSerialNumberTransceiver serial numberro DisplayString .1.3.6.1.4.1.3652.3.1.3.2.1.8 |
nmAgentPortsWavelengthTransceiver supported wavelength (nm)ro Integer32 .1.3.6.1.4.1.3652.3.1.3.2.1.9 |
nmAgentPortsSFPMeassurementTableSFP DMI meassurement table SEQUENCE OF NmAgentPortsSFPMeassurementEntry .1.3.6.1.4.1.3652.3.1.3.3 |
nmAgentPortsSFPMeassurementEntryModule transceiver DMI meassurement entries NmAgentPortsSFPMeassurementEntry .1.3.6.1.4.1.3652.3.1.3.3.1 |
nmAgentPortsSFPMIndexIndex Integer32 .1.3.6.1.4.1.3652.3.1.3.3.1.1 |
nmAgentPortsSFPMSlotSlot numberro Integer32 .1.3.6.1.4.1.3652.3.1.3.3.1.2 |
nmAgentPortsSFPMPortPort numberro Integer32 .1.3.6.1.4.1.3652.3.1.3.3.1.3 |
nmAgentPortsSFPDMIRxLeveloptical receive level (dBm value * 100)ro Integer32 .1.3.6.1.4.1.3652.3.1.3.3.1.4 |
nmAgentPortsSFPDMITxLeveloptical transmit level (dBm value * 100)ro Integer32 .1.3.6.1.4.1.3652.3.1.3.3.1.5 |
nmAgentPortsSFPDMITxBiasTransceiver hardware parameter: bias current (mA)ro Integer32 .1.3.6.1.4.1.3652.3.1.3.3.1.6 |
nmAgentPortsSFPDMIVccTransceiver hardware parameter: supply voltagero Integer32 .1.3.6.1.4.1.3652.3.1.3.3.1.7 |
nmAgentPortsSFPDMITempTransceiver hardware parameter: temperature (degree Celsius)ro Integer32 .1.3.6.1.4.1.3652.3.1.3.3.1.8 |
nmAgentPortsSFPAlarmTableSFP alarm table SEQUENCE OF NmAgentPortsSFPAlarmEntry .1.3.6.1.4.1.3652.3.1.3.4 |
nmAgentPortsSFPAlarmEntryModule transceiver alarm entries NmAgentPortsSFPAlarmEntry .1.3.6.1.4.1.3652.3.1.3.4.1 |
nmAgentPortsSFPAIndexIndex Integer32 .1.3.6.1.4.1.3652.3.1.3.4.1.1 |
nmAgentPortsSFPASlotSlot numberro Integer32 .1.3.6.1.4.1.3652.3.1.3.4.1.2 |
nmAgentPortsSFPAPortPort numberro Integer32 .1.3.6.1.4.1.3652.3.1.3.4.1.3 |
nmAgentPortsSFPDMIRxLowWarningEventTransceiver RX power eventro Enumeration .1.3.6.1.4.1.3652.3.1.3.4.1.4 |
nmAgentPortsSFPDMIRxLowAlarmEventTransceiver RX power eventro Enumeration .1.3.6.1.4.1.3652.3.1.3.4.1.5 |
nmAgentPortsSFPDMITxPowerAlarmTransceiver TX power eventro Enumeration .1.3.6.1.4.1.3652.3.1.3.4.1.6 |
nmAgentPortsSFPDMIBiasAlarmEventTransceiver bias current eventro Enumeration .1.3.6.1.4.1.3652.3.1.3.4.1.7 |
nmAgentPortsSFPDMIRxHighAlarmEventTransceiver RX power eventro Enumeration .1.3.6.1.4.1.3652.3.1.3.4.1.8 |
nmAgentPortsSFPDWDMTECAlarmEventTransceiver DWDM TEC alarm eventro Enumeration .1.3.6.1.4.1.3652.3.1.3.4.1.9 |
nmAgentPortsSFPTempAlarmEventTransceiver temperature alarm eventro Enumeration .1.3.6.1.4.1.3652.3.1.3.4.1.10 |
nmCarrier OBJECT IDENTIFIER .1.3.6.1.4.1.3652.3.2 |
nmCarrierGerneralInfo OBJECT IDENTIFIER .1.3.6.1.4.1.3652.3.2.1 |
nmCarrierNamename or location of the SPEED-CARRIER system. Allowed characters are 0-9 a-z A-Z '-' and '_'ro DisplayString .1.3.6.1.4.1.3652.3.2.1.1 |
nmCarrierTypeType of SPEED-CARRIER system (1U / 4 slots, 4U or 4,5U with 17 slots)ro Enumeration .1.3.6.1.4.1.3652.3.2.1.2 |
nmPSU1StatusStatus of PSU 1ro Enumeration .1.3.6.1.4.1.3652.3.2.1.3 |
nmPSU2StatusStatus of PSU 2ro Enumeration .1.3.6.1.4.1.3652.3.2.1.4 |
nmFanStateFan state of the SPEED-CARRIER systemro Enumeration .1.3.6.1.4.1.3652.3.2.1.5 |
nmCarrierPSU1Typetype of PSU 1ro Enumeration .1.3.6.1.4.1.3652.3.2.1.6 |
nmCarrierPSU2Typetype of PSU 2ro Enumeration .1.3.6.1.4.1.3652.3.2.1.7 |
nmCarrierPSU1TextPSU 1 customer descriptionro DisplayString .1.3.6.1.4.1.3652.3.2.1.8 |
nmCarrierPSU2TextPSU 2 customer descriptionro DisplayString .1.3.6.1.4.1.3652.3.2.1.9 |
nmCarrierPSU3TextPSU 3 customer descriptionro DisplayString .1.3.6.1.4.1.3652.3.2.1.10 |
nmCarrierPSU3Typetype of PSU 3ro Enumeration .1.3.6.1.4.1.3652.3.2.1.11 |
nmPSU3StatusStatus of PSU 3ro Enumeration .1.3.6.1.4.1.3652.3.2.1.12 |
nmCarrierSerialNumberserial number of the SPEED-CARRIER system.ro DisplayString .1.3.6.1.4.1.3652.3.2.1.13 |
nmCarrierAssemblyAlarmOne or more Module Cards are expected but not installedro Enumeration .1.3.6.1.4.1.3652.3.2.1.14 |
nmCarrierSlotOverviewTableCarrier slot overview table SEQUENCE OF NMCarrierSlotOverviewEntry .1.3.6.1.4.1.3652.3.2.2 |
nmCarrierSlotOverviewEntryCarrier slot overview NMCarrierSlotOverviewEntry .1.3.6.1.4.1.3652.3.2.2.1 |
nmCarrierSlotNumberSlot Number 1..17 for 4,xU Carrier, 1..16 for 5U Carrier, 1..19 for 5U High Power Carrier or 1..4 for 1U Carrierro Integer32 .1.3.6.1.4.1.3652.3.2.2.1.1 |
nmCarrierSlotTypeinstalled card type in this slotro DisplayString .1.3.6.1.4.1.3652.3.2.2.1.2 |
nmCarrierSlotPassiveTextuser defined text for passive cards. Is only available, if passive card is configuredro DisplayString .1.3.6.1.4.1.3652.3.2.2.1.3 |
nmFanOverviewTableFan overview table SEQUENCE OF NMFanOverviewEntry .1.3.6.1.4.1.3652.3.2.3 |
nmFanOverviewEntryFan overview table NMFanOverviewEntry .1.3.6.1.4.1.3652.3.2.3.1 |
nmFanGroupNumberFan group numberro Integer32 .1.3.6.1.4.1.3652.3.2.3.1.1 |
nmFanGroupStatusFor 1U Carrier group1 is the front fan and group2 the rear fan For 4.5U Carrier: group 1 and 2 are PSU 1 and 2. group 3 is the front fan below the slots and group 4 the rear fans.ro Enumeration .1.3.6.1.4.1.3652.3.2.3.1.2 |
nmCarrierFWUpdate OBJECT IDENTIFIER .1.3.6.1.4.1.3652.3.2.4 |
nmCarrierFWUpdateFilenamefilename for copying to slotsrw DisplayString .1.3.6.1.4.1.3652.3.2.4.1 |
nmCarrierFirmwareTransferConfigControl and status of upload procedurerw Enumeration .1.3.6.1.4.1.3652.3.2.4.2 |
nmCarrierFWTransferProgresscopy progress in percentro Integer32 .1.3.6.1.4.1.3652.3.2.4.3 |
nmCarrierFWUpdateConfigcopy and activates SW-images after next restartrw Enumeration .1.3.6.1.4.1.3652.3.2.4.4 |
nmCarrierFWUpdatePolicyTableupdate policy table SEQUENCE OF NMCarrierFWUpdatePolicyEntry .1.3.6.1.4.1.3652.3.2.5 |
nmCarrierFWUpdatePolicyEntryupdate policy NMCarrierFWUpdatePolicyEntry .1.3.6.1.4.1.3652.3.2.5.1 |
nmCarrierFWUpdatePolicySlotslot addressro Integer32 .1.3.6.1.4.1.3652.3.2.5.1.1 |
nmCarrierFWUpdatePolicyCardNamecard namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3652.3.2.5.1.2 |
nmCarrierFWUpdatePolicyConfigenable or disable updates for this slotrw Enumeration .1.3.6.1.4.1.3652.3.2.5.1.3 |
nmCarrierFWUpdatePolicyTransferStatefile transfer statero Enumeration .1.3.6.1.4.1.3652.3.2.5.1.4 |
nmCarrierConfigTransferTableupdate policy table SEQUENCE OF NMCarrierConfigTransferEntry .1.3.6.1.4.1.3652.3.2.6 |
nmCarrierConfigTransferEntryupdate policy NMCarrierConfigTransferEntry .1.3.6.1.4.1.3652.3.2.6.1 |
nmCarrierConfigSlotModule slot indexro Integer32 .1.3.6.1.4.1.3652.3.2.6.1.1 |
nmCarrierConfigModuleNameModule namero DisplayString .1.3.6.1.4.1.3652.3.2.6.1.2 |
nmCarrierConfigTransferStateconfig statero Enumeration .1.3.6.1.4.1.3652.3.2.6.1.3 |
nmCarrierConfigTransferconfig command for transfering filesrw Enumeration .1.3.6.1.4.1.3652.3.2.6.1.4 |
nmCarrierConfigFilenameactual stored config file or filename to be sendrw DisplayString .1.3.6.1.4.1.3652.3.2.6.1.5 |
nmCarrierConfigActivationconfig file activation at slotrw Enumeration .1.3.6.1.4.1.3652.3.2.6.1.6 |
nmCarrierInventoryTableCarrier inventory table SEQUENCE OF NMCarrierInventoryEntry .1.3.6.1.4.1.3652.3.2.7 |
nmCarrierInventoryEntryCarrier inventory NMCarrierInventoryEntry .1.3.6.1.4.1.3652.3.2.7.1 |
nmCarrierInventoryIndexInventory Index Integer32 .1.3.6.1.4.1.3652.3.2.7.1.1 |
nmCarrierInventorySlotNumberSlot Number 1..17 for 4,xU Carrier, 1..16 for 5U Carrier, 1..19 for 5U High Power Carrier or 1..4 for 1U Carrierro Integer32 .1.3.6.1.4.1.3652.3.2.7.1.2 |
nmCarrierInventoryPortport number in this slotro DisplayString .1.3.6.1.4.1.3652.3.2.7.1.3 |
nmCarrierInventoryModuleNamename of the modulero DisplayString .1.3.6.1.4.1.3652.3.2.7.1.4 |
nmCarrierInventoryPartNumberpart numberro DisplayString .1.3.6.1.4.1.3652.3.2.7.1.5 |
nmCarrierInventorySerialNumberserial numberro DisplayString .1.3.6.1.4.1.3652.3.2.7.1.6 |
nmCarrierInventoryFirmwareReleasefirmware release of the modulero DisplayString .1.3.6.1.4.1.3652.3.2.7.1.7 |
nmCarrierInventoryKernelLoaderKernel/Loader version of the modulero DisplayString .1.3.6.1.4.1.3652.3.2.7.1.8 |
converter OBJECT IDENTIFIER .1.3.6.1.4.1.3652.3.3 |
convSPEEDDUALLINE OBJECT IDENTIFIER .1.3.6.1.4.1.3652.3.3.1 |
convSxLModuleOverviewTableSPEEDDUALLINE module overview table SEQUENCE OF ConvSxLModuleOverviewEntry .1.3.6.1.4.1.3652.3.3.1.1 |
convSxLModuleOverviewEntryModule overview entries ConvSxLModuleOverviewEntry .1.3.6.1.4.1.3652.3.3.1.1.1 |
convSxLMSlotSlot No. in Carrierro Integer32 .1.3.6.1.4.1.3652.3.3.1.1.1.2 |
convSxLMDeviceModule DeviceTypero Enumeration .1.3.6.1.4.1.3652.3.3.1.1.1.3 |
convSxLMStatusStatus of inserted module. resetSoftware does not affect trafficrw Enumeration .1.3.6.1.4.1.3652.3.3.1.1.1.4 |
convSxLMSysUpTimeSystem uptime in secondsro TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.3652.3.3.1.1.1.5 |
convSxLMTempModule temperaturero Integer32 .1.3.6.1.4.1.3652.3.3.1.1.1.6 |
convSxLMAlarmStateModule alarm states, if they are active see Event-Tablero Enumeration .1.3.6.1.4.1.3652.3.3.1.1.1.7 |
convSxLMBootSWVersionModule bootloader software versionro DisplayString .1.3.6.1.4.1.3652.3.3.1.1.1.8 |
convSxLMAppSWVersionModule application software Versionro DisplayString .1.3.6.1.4.1.3652.3.3.1.1.1.9 |
convSxLMHWVersionModule board hardware versionro DisplayString .1.3.6.1.4.1.3652.3.3.1.1.1.10 |
convSxLMPLDVersionModule firmware versionro DisplayString .1.3.6.1.4.1.3652.3.3.1.1.1.11 |
convSxLMSerialNumberModules serial numberro DisplayString .1.3.6.1.4.1.3652.3.3.1.1.1.12 |
convSxLSWImagesOverviewTableSPEEDDUALLINE software images Overview Table SEQUENCE OF ConvSxLSWImagesOverviewEntry .1.3.6.1.4.1.3652.3.3.1.2 |
convSxLSWImagesOverviewEntryModule overview entries ConvSxLSWImagesOverviewEntry .1.3.6.1.4.1.3652.3.3.1.2.1 |
convSxLSWSlotSlot No. in Carrierro Integer32 .1.3.6.1.4.1.3652.3.3.1.2.1.2 |
convSxLSWBootImageIdentification of bootimagero DisplayString .1.3.6.1.4.1.3652.3.3.1.2.1.3 |
convSxLSWAppImage1Identification of application image1ro DisplayString .1.3.6.1.4.1.3652.3.3.1.2.1.4 |
convSxLSWAppImage2Identification of application image2ro DisplayString .1.3.6.1.4.1.3652.3.3.1.2.1.5 |
convSxLSWUploadStatusControl and status of upload procedurero Enumeration .1.3.6.1.4.1.3652.3.3.1.2.1.6 |
convSxLSWUpdateStatusactivates SW-image after next resetro Enumeration .1.3.6.1.4.1.3652.3.3.1.2.1.7 |
convSxLModuleConfigTableSPEEDDUALLINE config table SEQUENCE OF ConvSxLModuleConfigEntry .1.3.6.1.4.1.3652.3.3.1.3 |
convSxLModuleConfigEntryModule config entries ConvSxLModuleConfigEntry .1.3.6.1.4.1.3652.3.3.1.3.1 |
convSxLMCSlotSlot No. in Carrierro Integer32 .1.3.6.1.4.1.3652.3.3.1.3.1.2 |
convSxLMIpAddressModule IP addressro IpAddress .1.3.6.1.4.1.3652.3.3.1.3.1.3 |
convSxLMIpNetmaskModule netmaskro IpAddress .1.3.6.1.4.1.3652.3.3.1.3.1.4 |
convSxLMIpGatewayDefault gatewayro IpAddress .1.3.6.1.4.1.3652.3.3.1.3.1.5 |
convSxLMIpTftpServerTFTP server address for SW-Updatero IpAddress .1.3.6.1.4.1.3652.3.3.1.3.1.6 |
convSxLMIpTrapSinkSNMP TrapSink-addressro IpAddress .1.3.6.1.4.1.3652.3.3.1.3.1.7 |
convSxLMSNMPReadCommunitySNMP ReadCommunityro DisplayString .1.3.6.1.4.1.3652.3.3.1.3.1.8 |
convSxLMSNMPWriteCommunitySNMP WriteCommunityro DisplayString .1.3.6.1.4.1.3652.3.3.1.3.1.9 |
convSxLMTempWarningLevelWarning level for module ambient temperature (0 - 60 degree Celsius)rw Integer32 .1.3.6.1.4.1.3652.3.3.1.3.1.10 |
convSxLMTempAlarmLevelAlarm level for module ambient temperaturero Integer32 .1.3.6.1.4.1.3652.3.3.1.3.1.11 |
convSxLMAlarmReportControls alarm signaling modes of modulero Enumeration .1.3.6.1.4.1.3652.3.3.1.3.1.12 |
convSxLMEthPortConfigModule Ethernet Port configrw Enumeration .1.3.6.1.4.1.3652.3.3.1.3.1.13 |
convSxLMEthPortStateModule Ethernet Port statero Enumeration .1.3.6.1.4.1.3652.3.3.1.3.1.14 |
convSxLMCliUserTimeoutModule CLI User Timeoutrw Integer32 .1.3.6.1.4.1.3652.3.3.1.3.1.15 |
convSxLModuleProtectionTableSPEEDDUALLINE protection table SEQUENCE OF ConvSxLModuleProtectionEntry .1.3.6.1.4.1.3652.3.3.1.4 |
convSxLModuleProtectionEntryProtection table entries ConvSxLModuleProtectionEntry .1.3.6.1.4.1.3652.3.3.1.4.1 |
convSxLMPSlotSlot No. in Carrierro Integer32 .1.3.6.1.4.1.3652.3.3.1.4.1.2 |
convSxLMLinkProtectionConfigStatus of protection modulerw Enumeration .1.3.6.1.4.1.3652.3.3.1.4.1.3 |
convSxLMLinkProtectionStatusStatus of protection functionality regarding the link port. The link port are always port1 (main) and port2 (backup). The local port is port4ro Enumeration .1.3.6.1.4.1.3652.3.3.1.4.1.4 |
convSxLMLinkProtectionFallbackFallback time of errorfree seconds before switching back to MainPath. If there is an error during the Fallback-Time the timer will be restarted againrw Integer32 .1.3.6.1.4.1.3652.3.3.1.4.1.5 |
convSxLPortOverviewTablePort status table SEQUENCE OF ConvSxLPortOverviewEntry .1.3.6.1.4.1.3652.3.3.1.5 |
convSxLPortOverviewEntryPort status entries ConvSxLPortOverviewEntry .1.3.6.1.4.1.3652.3.3.1.5.1 |
convSxLPortIndexPort Index Integer32 .1.3.6.1.4.1.3652.3.3.1.5.1.1 |
convSxLSlotSlot numberro Integer32 .1.3.6.1.4.1.3652.3.3.1.5.1.2 |
convSxLPortPort numberro Integer32 .1.3.6.1.4.1.3652.3.3.1.5.1.3 |
convSxLDescriptionPort desription stringrw DisplayString .1.3.6.1.4.1.3652.3.3.1.5.1.4 |
convSxLAdminStatePort configuration modero Enumeration .1.3.6.1.4.1.3652.3.3.1.5.1.5 |
convSxLOperStatePort operational statero Enumeration .1.3.6.1.4.1.3652.3.3.1.5.1.6 |
convSxLSFPStateSFP-Port statero Enumeration .1.3.6.1.4.1.3652.3.3.1.5.1.7 |
convSxLLLCFStateStatus of linkloss configurationro Enumeration .1.3.6.1.4.1.3652.3.3.1.5.1.8 |
convSxLLoopStateStatus of loop configurationro Enumeration .1.3.6.1.4.1.3652.3.3.1.5.1.9 |
convSxLSpeedTxPort 3R regeneration speed and protocolro Enumeration .1.3.6.1.4.1.3652.3.3.1.5.1.10 |
convSxLTxPortConnectionStatus of port to port connectionro Enumeration .1.3.6.1.4.1.3652.3.3.1.5.1.11 |
convSxLAlarmStatePort warning / alarm statesro Enumeration .1.3.6.1.4.1.3652.3.3.1.5.1.12 |
convSxLDMIStateAvailability or version of Diagnostic Monitoring Information (DMI)ro Enumeration .1.3.6.1.4.1.3652.3.3.1.5.1.13 |
convSxLPortConfigTablePort config table SEQUENCE OF ConvSxLPortConfigEntry .1.3.6.1.4.1.3652.3.3.1.6 |
convSxLPortConfigEntryPort config entry ConvSxLPortConfigEntry .1.3.6.1.4.1.3652.3.3.1.6.1 |
convSxLCPortIndexPort Index Integer32 .1.3.6.1.4.1.3652.3.3.1.6.1.1 |
convSxLCSlotSlot numberro Integer32 .1.3.6.1.4.1.3652.3.3.1.6.1.2 |
convSxLCPortPort numberro Integer32 .1.3.6.1.4.1.3652.3.3.1.6.1.3 |
convSxLAdminConfigAdmin configuration of a specific portrw Enumeration .1.3.6.1.4.1.3652.3.3.1.6.1.4 |
convSxLLLCFConfigConfiguration of Link Loss Carry Forward (LLCF) function. If a link down event occurs on the link port the local port will be disabled to signal the error state to the locally connected device e.g. routerrw Enumeration .1.3.6.1.4.1.3652.3.3.1.6.1.5 |
convSxLLoopConfigSetup of loops. After a reset, all loops will be switched offrw Enumeration .1.3.6.1.4.1.3652.3.3.1.6.1.6 |
convSxLSpeedConfigTxPort 3R regeneration speed and protocolrw Enumeration .1.3.6.1.4.1.3652.3.3.1.6.1.7 |
convSxLPortConnectionSetup of connections. toPortx means a connection between Rx-input to Tx-outputrw Enumeration .1.3.6.1.4.1.3652.3.3.1.6.1.8 |
convSxLPortAlarmDeactivationPort alarm deactivation schedulerw Enumeration .1.3.6.1.4.1.3652.3.3.1.6.1.9 |
convSxLPortAlarmSchedulePort alarm deactivation schedule. Value in hours. After this time has elapsed, the alarms are active again. Valid range: 1..1200. 0 means less then 1 hourrw Integer32 .1.3.6.1.4.1.3652.3.3.1.6.1.10 |
convSxSFPIdentifikation OBJECT IDENTIFIER .1.3.6.1.4.1.3652.3.3.1.7 |
convSXLSFPDescriptionTableOptical transceiver parameter table SEQUENCE OF ConvSXLSFPDescriptionEntry .1.3.6.1.4.1.3652.3.3.1.7.1 |
convSXLSFPDescriptionEntryTalbe entries ConvSXLSFPDescriptionEntry .1.3.6.1.4.1.3652.3.3.1.7.1.1 |
convSxLSFPPortIndexPort Index Integer32 .1.3.6.1.4.1.3652.3.3.1.7.1.1.1 |
convSxLSFPSlotSlot numberro Integer32 .1.3.6.1.4.1.3652.3.3.1.7.1.1.2 |
convSxLSFPPortPort numberro Integer32 .1.3.6.1.4.1.3652.3.3.1.7.1.1.3 |
convSxLSFPVendorSFP vendor namero DisplayString .1.3.6.1.4.1.3652.3.3.1.7.1.1.4 |
convSxLSFPVendorOUIVendor specific IEEE-OUIro DisplayString .1.3.6.1.4.1.3652.3.3.1.7.1.1.5 |
convSxLSFPVendorCodePart identification code, vendor specificro DisplayString .1.3.6.1.4.1.3652.3.3.1.7.1.1.6 |
convSxLSFPVendorRevisionCodeParts revision code, vendor specificro DisplayString .1.3.6.1.4.1.3652.3.3.1.7.1.1.7 |
convSxLSFPVendorDateCodeThe vendor date code for the transceiver. The date code is specified in the following format: YYYY.MM.DD/LL; YYYY = year; MM = month; DD = day of month; LL = vendor lot codero DisplayString .1.3.6.1.4.1.3652.3.3.1.7.1.1.8 |
convSxLSFPVendorSerialNumberParts serial numberro DisplayString .1.3.6.1.4.1.3652.3.3.1.7.1.1.9 |
convSxLSFPTypePhysical type of devicero Enumeration .1.3.6.1.4.1.3652.3.3.1.7.1.1.10 |
convSxLSFPConnectorThe connector value indicates the external connector provided on the interface.ro Enumeration .1.3.6.1.4.1.3652.3.3.1.7.1.1.11 |
convSxLSFPWavelengthThe laser wavelength is the nominal transmitter output wavelength at room temperature. The value is in nanometers [nm]. This field allows the user to read the laser wavelength directly, so it is not necessary to infer it from the transceiver 'Code for Electronic Compatibility'.ro DisplayString .1.3.6.1.4.1.3652.3.3.1.7.1.1.12 |
convSxLSFPBitrateTableOptical transceiver bitrate table SEQUENCE OF ConvSxLSFPBitrateEntry .1.3.6.1.4.1.3652.3.3.1.7.2 |
convSxLSFPBitrateEntryTransceiver bitrate ConvSxLSFPBitrateEntry .1.3.6.1.4.1.3652.3.3.1.7.2.1 |
convSxLSFPBitratePortIndexPort Index Integer32 .1.3.6.1.4.1.3652.3.3.1.7.2.1.1 |
convSxLSFPBitrateSlotSlot numberro Integer32 .1.3.6.1.4.1.3652.3.3.1.7.2.1.2 |
convSxLSFPBitratePortPort numberro Integer32 .1.3.6.1.4.1.3652.3.3.1.7.2.1.3 |
convSxLSFPBitrateNominalThe nominal bit rate is specified in units of 1 Megabit per second, rounded up to the next 100 Megabits per second. The bit rate includes those bits necessary to encode and delimit the signal as well as those bits carrying data information. A value of 0 indicates that the bit rate is not specified and must be determined from the transceiver technology. The actual information transfer rate will depend on the data encoding defined by the encoding value.ro Enumeration .1.3.6.1.4.1.3652.3.3.1.7.2.1.4 |
convSxLSFPBitrateMaxThe upper bit rate limit at which the SFP transceiver will still meet its specifications is specified in units of 1 Megabit per second. A value of 0 indicates that this field is not specified.ro Enumeration .1.3.6.1.4.1.3652.3.3.1.7.2.1.5 |
convSxLSFPBitrateMinThe lower bit rate limit at which the SFP transceiver will still meet its specifications is specified in units of 1 Megabit per second. A value of 0 indicates that this field is not specified.ro Enumeration .1.3.6.1.4.1.3652.3.3.1.7.2.1.6 |
convSxLSFPLengthTableOptical Transceiver Length Table SEQUENCE OF ConvSxLSFPLengthEntry .1.3.6.1.4.1.3652.3.3.1.7.3 |
convSxLSFPLengthEntryOptical Transceiver Length Coding Entries ConvSxLSFPLengthEntry .1.3.6.1.4.1.3652.3.3.1.7.3.1 |
convSxLSFPLengthPortIndexPort Index Integer32 .1.3.6.1.4.1.3652.3.3.1.7.3.1.1 |
convSxLSFPLengthSlotSlot numberro Integer32 .1.3.6.1.4.1.3652.3.3.1.7.3.1.2 |
convSxLSFPLengthPortPort numberro Integer32 .1.3.6.1.4.1.3652.3.3.1.7.3.1.3 |
convSxLSFPLength9kmThis value specifies the link length that is supported by the SFP transceiver while operating in compliance with the applicable standards using single mode fiber. The value is in units of kilometers. A value of 255 means that the transceiver supports a link greater than 254 km. A value of 0 means that the transceiver does not support single mode fiber or that the length information must be determined from the transceiver technology.ro Enumeration .1.3.6.1.4.1.3652.3.3.1.7.3.1.4 |
convSxLSFPLength9mThis value specifies the link length that is supported by the SFP transceiver while operating in compliance with the applicable standards using single mode fiber. The value is in units of 100 meters. A value of 255 means that the transceiver supports a link greater than 25.4 km. A value of 0 means that the transceiver does not support single mode fiber or that the length information must be determined from the transceiver technology.ro Enumeration .1.3.6.1.4.1.3652.3.3.1.7.3.1.5 |
convSxLSFPLength50This value specifies the link length that is supported by the SFP transceiver while operating in compliance with the applicable standards using 50 micron multi mode fiber. The value is in units of 10 meters. A value of 255 means that the transceiver supports a link greater than 2.54 km. A value of 0 means that the transceiver does not support 50 micron multi mode fiber or that the length information must be determined from the transceiver technology.ro Enumeration .1.3.6.1.4.1.3652.3.3.1.7.3.1.6 |
convSxLSFPLength62This value specifies the link length that is supported by the SFP transceiver while operating in compliance with the applicable standards using 62.5 micron multi mode fiber. The value is in units of 10 meters. A value of 255 means that the transceiver supports a link greater than 2.54 km. A value of 0 means that the transceiver does not support 62.5 micron multi mode fiber or that the length information must be determined from the transceiver technology.ro Enumeration .1.3.6.1.4.1.3652.3.3.1.7.3.1.7 |
convSxLSFPLengthCopperThis value specifies the link length that is supported by the SFP transceiver while operating in compliance with the applicable standards using copper cable. The value is in units of 1 meter. A value of 255 means that the transceiver supports a link greater than 254 m. A value of 0 means that the transceiver does not support copper cable or that the length information must be determined from the transceiver technology. Further information about the cable design, equalization, and connectors is usually required to guarantee meeting of particular length information.ro Enumeration .1.3.6.1.4.1.3652.3.3.1.7.3.1.8 |
convSxLSFPCompCodes OBJECT IDENTIFIER .1.3.6.1.4.1.3652.3.3.1.7.4 |
convSxLSFPCompCodeSonetTableOptical transceiver sonet compatibility table SEQUENCE OF ConvSxLSFPCompCodeSonetEntry .1.3.6.1.4.1.3652.3.3.1.7.4.1 |
convSxLSFPCompCodeSonetEntryTransceiver compatibility code entries ConvSxLSFPCompCodeSonetEntry .1.3.6.1.4.1.3652.3.3.1.7.4.1.1 |
convSxLSFPCSPortIndexPort Index Integer32 .1.3.6.1.4.1.3652.3.3.1.7.4.1.1.1 |
convSxLSFPCSSlotSlot numberro Integer32 .1.3.6.1.4.1.3652.3.3.1.7.4.1.1.2 |
convSxLSFPCSPortPort numberro Integer32 .1.3.6.1.4.1.3652.3.3.1.7.4.1.1.3 |
convSxLSFPCSProtocolSupported protocolro Enumeration .1.3.6.1.4.1.3652.3.3.1.7.4.1.1.4 |
convSxLSFPCSRangeOptical transceivers rangero Enumeration .1.3.6.1.4.1.3652.3.3.1.7.4.1.1.5 |
convSxLSFPCSFiberTypeSupported fiber typero Enumeration .1.3.6.1.4.1.3652.3.3.1.7.4.1.1.6 |
convSxLSFPCompCodeGigabitEthernetTableOptical transceiver gigabit Ethernet compatibility table SEQUENCE OF ConvSxLSFPCompCodeGigabitEthernetEntry .1.3.6.1.4.1.3652.3.3.1.7.4.2 |
convSxLSFPCompCodeGigabitEthernetEntryTable entries ConvSxLSFPCompCodeGigabitEthernetEntry .1.3.6.1.4.1.3652.3.3.1.7.4.2.1 |
convSxLSFPCGPortIndexPort Index Integer32 .1.3.6.1.4.1.3652.3.3.1.7.4.2.1.1 |
convSxLSFPCGSlotSlot numberro Integer32 .1.3.6.1.4.1.3652.3.3.1.7.4.2.1.2 |
convSxLSFPCGPortPort numberro Integer32 .1.3.6.1.4.1.3652.3.3.1.7.4.2.1.3 |
convSxLSFPCGTypeSupported protocolro Enumeration .1.3.6.1.4.1.3652.3.3.1.7.4.2.1.4 |
convSxLSFPCompCodeFibreChannelTableOptical transceiver fibre channel compatibility table SEQUENCE OF ConvSxLSFPCompCodeFibreChannelEntry .1.3.6.1.4.1.3652.3.3.1.7.4.3 |
convSxLSFPCompCodeFibreChannelEntryTable entries ConvSxLSFPCompCodeFibreChannelEntry .1.3.6.1.4.1.3652.3.3.1.7.4.3.1 |
convSxLSFPCFcPortIndexPort Index Integer32 .1.3.6.1.4.1.3652.3.3.1.7.4.3.1.1 |
convSxLSFPCFcSlotSlot numberro Integer32 .1.3.6.1.4.1.3652.3.3.1.7.4.3.1.2 |
convSxLSFPCFcPortPort numberro Integer32 .1.3.6.1.4.1.3652.3.3.1.7.4.3.1.3 |
convSxLSFPCFcMediaSupported media typesro Enumeration .1.3.6.1.4.1.3652.3.3.1.7.4.3.1.4 |
convSxLSFPCFcTechTransmitter technologyro Enumeration .1.3.6.1.4.1.3652.3.3.1.7.4.3.1.5 |
convSxLSFPCFcLinkLengthLink length supported by transceiverro Enumeration .1.3.6.1.4.1.3652.3.3.1.7.4.3.1.6 |
convSxLSFPCFcSpeedFibre channel speedro Enumeration .1.3.6.1.4.1.3652.3.3.1.7.4.3.1.7 |
convSxLCopperSFPTableOverview and configuration of copper SFP table SEQUENCE OF ConvSxLCopperSFPEntry .1.3.6.1.4.1.3652.3.3.1.7.5 |
convSxLCopperSFPEntryTransceiver overview and configuration entries ConvSxLCopperSFPEntry .1.3.6.1.4.1.3652.3.3.1.7.5.1 |
convSxLCuSFPPortIndexPort Index Integer32 .1.3.6.1.4.1.3652.3.3.1.7.5.1.1 |
convSxLCuSFPSlotSlot numberro Integer32 .1.3.6.1.4.1.3652.3.3.1.7.5.1.2 |
convSxLCuSFPPortPort numberro Integer32 .1.3.6.1.4.1.3652.3.3.1.7.5.1.3 |
convSxLConfigSpeedUser defined configuration of speedrw Enumeration .1.3.6.1.4.1.3652.3.3.1.7.5.1.4 |
convSxLConfigDuplexUser defined configuration of duplex moderw Enumeration .1.3.6.1.4.1.3652.3.3.1.7.5.1.5 |
convSxLCuPhyIdPhysical transceiver installed in SFP, if unkown the transceiver is not supportedro Enumeration .1.3.6.1.4.1.3652.3.3.1.7.5.1.6 |
convSxLCuSFPLinkLink status of internal physical in copper SFPro Enumeration .1.3.6.1.4.1.3652.3.3.1.7.5.1.7 |
convSxLCuSFPSpeedactual speed status of internal physical in copper SFPro Enumeration .1.3.6.1.4.1.3652.3.3.1.7.5.1.8 |
convSxLCuSFPDuplexactual duplex mode status of internal physical in copper SFPro Enumeration .1.3.6.1.4.1.3652.3.3.1.7.5.1.9 |
convSxLCuSFPAutoMDIxactual of status MDI-connection in copper SFPrw Enumeration .1.3.6.1.4.1.3652.3.3.1.7.5.1.10 |
convSxLCuSFPConfigModeactual config mode in copper SFPrw Enumeration .1.3.6.1.4.1.3652.3.3.1.7.5.1.11 |
convSxLDWDMSFPTableOverview and configuration of DWDM SFP table SEQUENCE OF ConvSxLDWDMSFPEntry .1.3.6.1.4.1.3652.3.3.1.7.6 |
convSxLDWDMSFPEntryTransceiver overview and configuration entries ConvSxLDWDMSFPEntry .1.3.6.1.4.1.3652.3.3.1.7.6.1 |
convSxLDWDMPortIndexPort Index Integer32 .1.3.6.1.4.1.3652.3.3.1.7.6.1.1 |
convSxLDWDMSlotSlot numberro Integer32 .1.3.6.1.4.1.3652.3.3.1.7.6.1.2 |
convSxLDWDMPortPort numberro Integer32 .1.3.6.1.4.1.3652.3.3.1.7.6.1.3 |
convSxLDWDMPowerClassPower class of installed DWDM-SFPro Enumeration .1.3.6.1.4.1.3652.3.3.1.7.6.1.4 |
convSxLDWDMMaxSupplyCurrentDefines the maximum supply current the module will consume under worst conditions in units of 4mAro Integer32 .1.3.6.1.4.1.3652.3.3.1.7.6.1.5 |
convSxLChannelSpacingIdentifies the densest channel spacing the module is compatible withro Enumeration .1.3.6.1.4.1.3652.3.3.1.7.6.1.6 |
convSxLNumberofChannelsIdentifies the number of channels over which the module may be tuned by user command. If not tunable the number is 1ro Integer32 .1.3.6.1.4.1.3652.3.3.1.7.6.1.7 |
convSxLSFPDMIParamTableOptical transceiver measurement parameter table SEQUENCE OF ConvSxLSFPDMIParamEntry .1.3.6.1.4.1.3652.3.3.1.8 |
convSxLSFPDMIParamEntryTable entries ConvSxLSFPDMIParamEntry .1.3.6.1.4.1.3652.3.3.1.8.1 |
convSxLSFPDMIPortIndexPort Indexro Integer32 .1.3.6.1.4.1.3652.3.3.1.8.1.1 |
convSxLSFPDMISlotSlot numberro Integer32 .1.3.6.1.4.1.3652.3.3.1.8.1.2 |
convSxLSFPDMIPortPort numberro Integer32 .1.3.6.1.4.1.3652.3.3.1.8.1.3 |
convSxLSFPDMIRxLevelOptical receive powerro Integer32 .1.3.6.1.4.1.3652.3.3.1.8.1.4 |
convSxLSFPDMIRxHighAlarmStatus of receive optical power, active when overloadedro Enumeration .1.3.6.1.4.1.3652.3.3.1.8.1.5 |
convSxLSFPDMITxLevelOptical transmit powerro Integer32 .1.3.6.1.4.1.3652.3.3.1.8.1.6 |
convSxLSFPDMITxBiasTransceiver hardware parameter: laser bias currentro Integer32 .1.3.6.1.4.1.3652.3.3.1.8.1.7 |
convSxLSFPDMIVccTransceiver hardware parameter: supply voltagero Integer32 .1.3.6.1.4.1.3652.3.3.1.8.1.8 |
convSxLSFPDMITempTransceiver hardware parameter: temperature valuero Integer32 .1.3.6.1.4.1.3652.3.3.1.8.1.9 |
convSxLSFPDMIThresholdTableOptical transceiver measurement threshold table SEQUENCE OF ConvSxLSFPDMIThresholdEntry .1.3.6.1.4.1.3652.3.3.1.9 |
convSxLSFPDMIThresholdEntryMeasurement parameter overview ConvSxLSFPDMIThresholdEntry .1.3.6.1.4.1.3652.3.3.1.9.1 |
convSxLSFPDMITPortIndexPort Index Integer32 .1.3.6.1.4.1.3652.3.3.1.9.1.1 |
convSxLSFPDMITSlotSlot numberro Integer32 .1.3.6.1.4.1.3652.3.3.1.9.1.2 |
convSxLSFPDMITPortPort numberro Integer32 .1.3.6.1.4.1.3652.3.3.1.9.1.3 |
convSxLSFPDMITRxLowThresholdWarningLevelOptical receive power warning level. Value display and set is dBm/100rw Integer32 .1.3.6.1.4.1.3652.3.3.1.9.1.4 |
convSxLSFPDMITRxLowThresholdAlarmLevelOptical receive power alarm level. Value display is dBm/100ro Integer32 .1.3.6.1.4.1.3652.3.3.1.9.1.5 |
convSxLSFPDMITTxLowThresholdWarningLevelOptical transmit power warning level. Value display and set is dBm/100rw Integer32 .1.3.6.1.4.1.3652.3.3.1.9.1.6 |
convSxLSFPDMITTxLowThresholdAlarmLevelOptical transmit power alarm level. Value display is dBm/100ro Integer32 .1.3.6.1.4.1.3652.3.3.1.9.1.7 |
convSxLSFPDMITThresholdsUsageSet threshold usage. Activate user defined or vendor defined thresholdsrw Enumeration .1.3.6.1.4.1.3652.3.3.1.9.1.8 |
convSxLPortEventTablePort event Table SEQUENCE OF ConvSxLPortEventEntry .1.3.6.1.4.1.3652.3.3.1.10 |
convSxLPortEventEntryPort event table entries ConvSxLPortEventEntry .1.3.6.1.4.1.3652.3.3.1.10.1 |
convSxLSFPEPortIndexPort Index Integer32 .1.3.6.1.4.1.3652.3.3.1.10.1.1 |
convSxLSFPESlotSlot numberro Integer32 .1.3.6.1.4.1.3652.3.3.1.10.1.2 |
convSxLSFPEPortPort numberro Integer32 .1.3.6.1.4.1.3652.3.3.1.10.1.3 |
convSxLSFPDMIRxLowWarningEventReceive power - low warningro Enumeration .1.3.6.1.4.1.3652.3.3.1.10.1.4 |
convSxLSFPDMIRxLowAlarmEventReceive power - low alarmro Enumeration .1.3.6.1.4.1.3652.3.3.1.10.1.5 |
convSxLSFPDMITxLowWarningEventOutput power - low warningro Enumeration .1.3.6.1.4.1.3652.3.3.1.10.1.6 |
convSxLSFPDMITxLowAlarmEventOutput power - low alarmro Enumeration .1.3.6.1.4.1.3652.3.3.1.10.1.7 |
convSxLSFPDMIBiasAlarmEventTransmitter bias current is lowro Enumeration .1.3.6.1.4.1.3652.3.3.1.10.1.8 |
convSxLSFPDMIRxHighAlarmEventReceiver input power is highro Enumeration .1.3.6.1.4.1.3652.3.3.1.10.1.9 |
convSxLSFPDWDMLaserTHighAlarmEventSet when laser temperature or wavelength exceeds high alarm level.ro Enumeration .1.3.6.1.4.1.3652.3.3.1.10.1.10 |
convSxLSFPDWDMLaserTLowAlarmEventSet when laser temperature or wavelength exceeds low alarm level.ro Enumeration .1.3.6.1.4.1.3652.3.3.1.10.1.11 |
convSxLSFPDWDMTECHighAlarmEventSet when TEC current exceeds high alarm level (cooling problem)ro Enumeration .1.3.6.1.4.1.3652.3.3.1.10.1.12 |
convSxLSFPDWDMTECLowAlarmEventSet when TEC current exceeds low alarm level (heating problem)ro Enumeration .1.3.6.1.4.1.3652.3.3.1.10.1.13 |
convSxLSFPDMITempHighWarningEventTransceiver DMI temperature high warning eventro Enumeration .1.3.6.1.4.1.3652.3.3.1.10.1.14 |
convSxLSFPDMITempHighAlarmEventTransceiver DMI temperature high alarm eventro Enumeration .1.3.6.1.4.1.3652.3.3.1.10.1.15 |
convSxLInventoryTableTable of all serial numbers installed in module SEQUENCE OF ConvSxLInventoryEntry .1.3.6.1.4.1.3652.3.3.1.11 |
convSxLInventoryEntryTable entries ConvSxLInventoryEntry .1.3.6.1.4.1.3652.3.3.1.11.1 |
convSxLInvSlotSlot No. in Carrierro Integer32 .1.3.6.1.4.1.3652.3.3.1.11.1.2 |
convSxLModuleSerialNumberSerial number of modulero DisplayString .1.3.6.1.4.1.3652.3.3.1.11.1.3 |
convSxLSFPPort1SerialNumberSerial number of installed transceiverro DisplayString .1.3.6.1.4.1.3652.3.3.1.11.1.4 |
convSxLSFPPort2SerialNumberSerial number of installed transceiverro DisplayString .1.3.6.1.4.1.3652.3.3.1.11.1.5 |
convSxLSFPPort3SerialNumberSerial number of installed transceiverro DisplayString .1.3.6.1.4.1.3652.3.3.1.11.1.6 |
convSxLSFPPort4SerialNumberSerial number of installed transceiverro DisplayString .1.3.6.1.4.1.3652.3.3.1.11.1.7 |
multiplexer OBJECT IDENTIFIER .1.3.6.1.4.1.3652.3.4 |
amplifier OBJECT IDENTIFIER .1.3.6.1.4.1.3652.3.5 |