Home/Catalog/SCHLEIFENBAUER-DATABUS-MIB

SCHLEIFENBAUER-DATABUS-MIB

AI MIB Summary

The SCHLEIFENBAUER-DATABUS-MIB enables SNMP-based monitoring and management of Schleifenbauer network-enabled databus devices, specifically tracking communication session states, data throughput counters, and interface operational status. This module facilitates the collection of device health metrics and error statistics required for maintaining the integrity of industrial data bus networks.

This MIB describes the SNMP functions of network enabled databus devices. Copyright (c) 2016 by Schleifenbauer Holding BV
Main OID:
schleifenbauerDatabusMIB.1.3.6.1.4.1.31034.12.1
164
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

164 total
Object Name
schleifenbauerDatabusMIBThis MIB describes the SNMP functions of network enabled databus devices. Copyright (c) 2016 by Schleifenbauer Holding BV
MODULE-IDENTITY
.1.3.6.1.4.1.31034.12.1
sdbMIBNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.31034.12.1.0
sdbDevSsDeviceStatusCodeChangedDevice status code changed. OBJECTS { sdbDevSsDeviceStatusCode }
NOTIFICATION-TYPE
.1.3.6.1.4.1.31034.12.1.0.1
sdbDevSsTemperatureAlertDetectedTemperature alert detected. Internal temperature alert: OBJECTS { sdbDevSsTemperatureAlert, sdbDevMsIntTemperature, sdbDevMsIntTemperaturePeak } External analog temperature alert: OBJECTS { sdbDevSsTemperatureAlert, sdbDevMsExtTemperature, sdbDevMsExtTemperaturePeak } External digital temperature alert: OBJECTS { sdbDevSsTemperatureAlert, sdbDevSnsValue }
NOTIFICATION-TYPE
.1.3.6.1.4.1.31034.12.1.0.2
sdbDevSsInputCurrentAlertDetectedInput current alert detected. OBJECTS { sdbDevSsInputCurrentAlert, sdbDevInActualCurrent }
NOTIFICATION-TYPE
.1.3.6.1.4.1.31034.12.1.0.3
sdbDevSsOutletCurrentAlertDetectedOutlet current alert detected. OBJECTS { sdbDevSsOutletCurrentAlert, sdbDevOutMtActualCurrent }
NOTIFICATION-TYPE
.1.3.6.1.4.1.31034.12.1.0.4
sdbDevSsInputVoltageAlertDetectedInput voltage alert detected. OBJECTS { sdbDevSsInputVoltageAlert, sdbDevInActualVoltage }
NOTIFICATION-TYPE
.1.3.6.1.4.1.31034.12.1.0.5
sdbDevSsOutletCurrentDropAlertDetectedOutlet current drop alert detected. OBJECTS { sdbDevSsOutletCurrentDropAlert, sdbDevOutMtActualCurrent }
NOTIFICATION-TYPE
.1.3.6.1.4.1.31034.12.1.0.6
sdbDevSsInputCurrentDropAlertDetectedInput current drop alert detected. OBJECTS { sdbDevSsInputCurrentDropAlert, sdbDevInActualCurrent }
NOTIFICATION-TYPE
.1.3.6.1.4.1.31034.12.1.0.7
sdbDevSsSensorChangeAlertDetectedSensor channel change alert detected. OBJECTS { sdbDevSsSensorChangeAlert }
NOTIFICATION-TYPE
.1.3.6.1.4.1.31034.12.1.0.8
sdbMgmtStsRingStateChangedRing state changed. Ring state changded to open: OBJECTS { sdbMgmtStsRingState, sdbMgmtStsRingBreachIndex } Ring state changded to closed: OBJECTS { sdbMgmtStsRingState }
NOTIFICATION-TYPE
.1.3.6.1.4.1.31034.12.1.0.9
sdbDevSsOutletVoltageDropAlertDetectedOutlet voltage drop alert detected. OBJECTS { sdbDevSsOutletVoltageDropAlert, sdbDevOutMtActualVoltage }
NOTIFICATION-TYPE
.1.3.6.1.4.1.31034.12.1.0.10
sdbMIBObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.31034.12.1.1
sdbMgmt
OBJECT IDENTIFIER
.1.3.6.1.4.1.31034.12.1.1.1
sdbMgmtStatus
OBJECT IDENTIFIER
.1.3.6.1.4.1.31034.12.1.1.1.1
sdbMgmtStsDevicesThe number of devices on the databus.ro
Integer32
.1.3.6.1.4.1.31034.12.1.1.1.1.1
sdbMgmtStsAddressableDevicesThe number of devices on the databus addressable by snmp.ro
Integer32
.1.3.6.1.4.1.31034.12.1.1.1.1.2
sdbMgmtStsNewDevicesThe number of new devices on the databus.ro
Integer32
.1.3.6.1.4.1.31034.12.1.1.1.1.3
sdbMgmtStsDuplicateDevicesThe number of duplicate devices on the databus.ro
Integer32
.1.3.6.1.4.1.31034.12.1.1.1.1.4
sdbMgmtStsRingStateIf the device is in a bridge-like mode, this will indicate the actual state of the databus.ro
Enumeration
.1.3.6.1.4.1.31034.12.1.1.1.1.5
sdbMgmtStsRingBreachIndexIndicates the breach index if the current state of the data bus is open. If the data bus is closed this has no meaning.ro
Integer32
.1.3.6.1.4.1.31034.12.1.1.1.1.6
sdbMgmtControl
OBJECT IDENTIFIER
.1.3.6.1.4.1.31034.12.1.1.1.2
sdbMgmtCtrlScanPerform a bus scan. To verify if scanning is completed the value of this object can be read. During the bus scan the value remains 1. When the bus scan completed the value will be 0.rw
Enumeration
.1.3.6.1.4.1.31034.12.1.1.1.2.1
sdbMgmtCtrlRenumberAllFromNRenumber all devices on the databus. If set to 0 all units will be set to 0. If set to another value, all units will be numbered in sequence starting from the value set.rw
Integer32
.1.3.6.1.4.1.31034.12.1.1.1.2.2
sdbMgmtCtrlRenumberZerosRenumber all devices on the databus having address 0. Renumbering will be done in sequence. The sequence starts with the highest address found on the databus.rw
Enumeration
.1.3.6.1.4.1.31034.12.1.1.1.2.3
sdbMgmtCtrlDevicesTableA table containing information of devices connected to the databus. The number of entries is given by the value of sdbMgmtStsDevices.
SEQUENCE OF SdbMgmtCtrlDevicesEntry
.1.3.6.1.4.1.31034.12.1.1.1.2.4
sdbMgmtCtrlDevicesEntryInformation entry containing objects of a particular databus device.
SdbMgmtCtrlDevicesEntry
.1.3.6.1.4.1.31034.12.1.1.1.2.4.1
sdbMgmtCtrlDevIndexA unique value for each device. Its value ranges between 1 and the value of sdbMgmtStsDevices with a maximum of 255. The value for each device will remain constant until the next scan is performed.
Integer32
.1.3.6.1.4.1.31034.12.1.1.1.2.4.1.1
sdbMgmtCtrlDevUnitAddressUser defined address. This will be used for addressing the device on the databus.rw
Integer32
.1.3.6.1.4.1.31034.12.1.1.1.2.4.1.2
sdbMgmtCtrlDevHardwareAddressHardware serial number. This cannot be changed. It can be used as backup unit address. format as 3 unsigned ints separated by dashes: int - int - intro
DisplayString
.1.3.6.1.4.1.31034.12.1.1.1.2.4.1.3
sdbMgmtCtrlDevIsNewIndication if the device is new on the databus.ro
Enumeration
.1.3.6.1.4.1.31034.12.1.1.1.2.4.1.4
sdbMgmtCtrlDevIsDuplicateIndication if the device is conflicting with another device on the databus.ro
Enumeration
.1.3.6.1.4.1.31034.12.1.1.1.2.4.1.5
sdbDevice
OBJECT IDENTIFIER
.1.3.6.1.4.1.31034.12.1.1.2
sdbDevIdentification
OBJECT IDENTIFIER
.1.3.6.1.4.1.31034.12.1.1.2.1
sdbDevIdTableA table containing identification information of devices connected to the databus. The number of entries is given by the value of sdbMgmtStsAddressableDevices.
SEQUENCE OF SdbDevIdEntry
.1.3.6.1.4.1.31034.12.1.1.2.1.1
sdbDevIdEntryInformation entry containing information objects of a particular databus device.
SdbDevIdEntry
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1
sdbDevIdSPDMVersionData model version.ro
Integer32
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.1
sdbDevIdFirmwareVersionThe firmware revision number.ro
Integer32
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.2
sdbDevIdBuildNumberDate and time the firmware was built.ro
DisplayString
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.3
sdbDevIdSalesOrderNumberSP sales order number.ro
DisplayString
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.4
sdbDevIdProductIdSP product id.ro
DisplayString
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.5
sdbDevIdSerialNumberSP serial number.ro
DisplayString
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.6
sdbDevIdHardwareAddressHardware serial number. This can not be changed. It can be used as backup unit address. Format as 3 unsigned ints separated by dashes (-) e.g. 12345-54321-00000ro
DisplayString
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.7
sdbDevIdMacAddressThe MAC address. This can not be changed. It represents an 802 MAC address as if it were transmitted least significant bit first. Format as six groups of 2 hexadecimal digits separated by colons (:) e.g. D0:22:12:B0:00:00ro
DisplayString
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.8
sdbDevIdUnitAddressUser defined address. This will be used for addressing the device on the databus.rw
Integer32
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.9
sdbDevIdNameUser configurable device name or identifier.rw
DisplayString
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.10
sdbDevIdLocationUser configurable device location identifier.rw
DisplayString
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.11
sdbDevIdVanityTagCharacters to be displayed as vanity text in display.rw
DisplayString
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.12
sdbDevIdIndexA unique value for each device. Its value represents the unit address of the device and is used to address individual devices in the tree. The value for each device will remain constant until the next scan is performed.
Integer32
.1.3.6.1.4.1.31034.12.1.1.2.1.1.1.13
sdbDevConfiguration
OBJECT IDENTIFIER
.1.3.6.1.4.1.31034.12.1.1.2.2
sdbDevCfTableA table containing configuration information of devices connected to the databus. The number of entries is given by the value of sdbMgmtStsAddressableDevices.
SEQUENCE OF SdbDevCfEntry
.1.3.6.1.4.1.31034.12.1.1.2.2.1
sdbDevCfEntryConfiguration entry containing configuration objects of a particular databus device.
SdbDevCfEntry
.1.3.6.1.4.1.31034.12.1.1.2.2.1.1
sdbDevCfPhasesNumber of phases for input metering.ro
Integer32 (0 | 1 | 3)
.1.3.6.1.4.1.31034.12.1.1.2.2.1.1.1
sdbDevCfOutletsTotalTotal number of outlets including hardwired without switch/metered modules.ro
Integer32
.1.3.6.1.4.1.31034.12.1.1.2.2.1.1.2
sdbDevCfOutletsSwitchedNumber of switched outlets. If outlet numbering is non-contiguous its the highest outlet number.ro
Integer32
.1.3.6.1.4.1.31034.12.1.1.2.2.1.1.3
sdbDevCfOutletsMeteredNumber of metered outlets. If outlet numbering is non-contiguous its the highest outlet number.ro
Integer32
.1.3.6.1.4.1.31034.12.1.1.2.2.1.1.4
sdbDevCfSensorsThe number sensors.ro
Integer32
.1.3.6.1.4.1.31034.12.1.1.2.2.1.1.5
sdbDevCfMaximumLoadMaximum rated load of device per phasero
Integer32 (16 | 32) UNITS "A"
.1.3.6.1.4.1.31034.12.1.1.2.2.1.1.6
sdbDevSystemStatus
OBJECT IDENTIFIER
.1.3.6.1.4.1.31034.12.1.1.2.3
sdbDevSsTableA table containing system status information of devices connected to the databus. The number of entries is given by the value of sdbMgmtStsAddressableDevices.
SEQUENCE OF SdbDevSsEntry
.1.3.6.1.4.1.31034.12.1.1.2.3.1
sdbDevSsEntrySystem status entry containing system status objects of a particular databus device.
SdbDevSsEntry
.1.3.6.1.4.1.31034.12.1.1.2.3.1.1
sdbDevSsDeviceStatusCodeReturns an internal status or error code. A value of 0 means OK. If not 0 it can be any of the following codes. Multiple status codes can be active at the same time. The value will be the sum of the active status codes. 1 = alert flagged 2 = settings(s) initialized 4 = power-on reset 8 = external reset 16 = watchdog timer caused reset 32 = brownout detected 64 = controller error 128 = slave module was resetro
Integer32
.1.3.6.1.4.1.31034.12.1.1.2.3.1.1.1
sdbDevSsTemperatureAlertAn alert has been raised due to temperature exceeding treshhold. 0 = no alert 1 = internal temperature sensor 2 = external temperature sensorro
Integer32
.1.3.6.1.4.1.31034.12.1.1.2.3.1.1.2
sdbDevSsInputCurrentAlertAn alert has been raised due to current exceeding treshhold. The value indicates the exceeding phase. 0 = no alert.ro
Integer32
.1.3.6.1.4.1.31034.12.1.1.2.3.1.1.3
sdbDevSsOutletCurrentAlertAn alert has been raised due to current exceeding treshhold. The value indicates the exceeding outlet. 0 = no alert.ro
Integer32
.1.3.6.1.4.1.31034.12.1.1.2.3.1.1.4
sdbDevSsInputVoltageAlertAn alert has been raised due to a voltage dip. The value indicates the dipped phase. 0 = no alert.ro
Integer32
.1.3.6.1.4.1.31034.12.1.1.2.3.1.1.5
sdbDevSsOutletCurrentDropAlertAn alert has been raised due to the current of a metered outlet suddenly dropping to near zero, possibly indicating a blown fuse. The value indicates the dropped outlet. 0 = no alert.ro
Integer32
.1.3.6.1.4.1.31034.12.1.1.2.3.1.1.6
sdbDevSsInputCurrentDropAlertAn alert has been raised due to the current of a metered input suddenly dropping to near zero, possibly indicating a blown fuse. The value indicates the dropped phase. 0 = no alert.ro
Integer32
.1.3.6.1.4.1.31034.12.1.1.2.3.1.1.7
sdbDevSsSensorChangeAlertAn alert has been raised due to a change in the number of sensors. The value indicates the previous amount of sensors.ro
Integer32
.1.3.6.1.4.1.31034.12.1.1.2.3.1.1.8
sdbDevSsOutletVoltageDropAlertAn alert has been raised due to voltage drop on this outlet. The value indicates the first failed outlet.ro
Integer32
.1.3.6.1.4.1.31034.12.1.1.2.3.1.1.9
sdbDevReset
OBJECT IDENTIFIER
.1.3.6.1.4.1.31034.12.1.1.2.4
sdbDevRsTableA table providing reset capabilities to devices connected to the databus. The number of entries is given by the value of sdbMgmtStsAddressableDevices.
SEQUENCE OF SdbDevRsEntry
.1.3.6.1.4.1.31034.12.1.1.2.4.1
sdbDevRsEntryReset entry providing reset objects of a particular databus device.
SdbDevRsEntry
.1.3.6.1.4.1.31034.12.1.1.2.4.1.1
sdbDevRsRebootWarm reboot/reset of device controller. NOTE: this will have NO effect on outlet status!rw
Enumeration
.1.3.6.1.4.1.31034.12.1.1.2.4.1.1.1
sdbDevRsResetAlertsReset all alert signals and device status code.rw
Enumeration
.1.3.6.1.4.1.31034.12.1.1.2.4.1.1.2
sdbDevRsZeroInputKWhSubtotalReset of all input kWh subtotal counters to zero.rw
Enumeration
.1.3.6.1.4.1.31034.12.1.1.2.4.1.1.3
sdbDevRsZeroOutletKWhSubtotalReset of all outlet kWh subtotal counter to zero.rw
Enumeration
.1.3.6.1.4.1.31034.12.1.1.2.4.1.1.4
sdbDevRsResetPeaksAndDipsReset all peak and dip values to zero.rw
Enumeration
.1.3.6.1.4.1.31034.12.1.1.2.4.1.1.5
sdbDevSettings
OBJECT IDENTIFIER
.1.3.6.1.4.1.31034.12.1.1.2.5
sdbDevStTableA table containing setting information of devices connected to the databus. The number of entries is given by the value of sdbMgmtStsAddressableDevices.
SEQUENCE OF SdbDevStEntry
.1.3.6.1.4.1.31034.12.1.1.2.5.1
sdbDevStEntrySetting entry containing settings objects of a particular databus device.
SdbDevStEntry
.1.3.6.1.4.1.31034.12.1.1.2.5.1.1
sdbDevStAutoResetAlertsAuto reset alerts configuration. If set to 0 the auto reset alerts feature is disabled. If set to a value greater then 0, the auto reset alerts feature is enabled and alerts will get cleared after the configured amount of seconds since the last alert condition have passed.rw
Integer32
.1.3.6.1.4.1.31034.12.1.1.2.5.1.1.2
sdbDevStExtendedNamesUse original or longer names for inputs, outlets and sensors.rw
Enumeration
.1.3.6.1.4.1.31034.12.1.1.2.5.1.1.3
sdbDevStPeakDurationAmount of ms a current peak should last before an alert is raised.rw
MilliSecond
.1.3.6.1.4.1.31034.12.1.1.2.5.1.1.4
sdbDevStFixedOutletDelayMinimal delay between two successive relay switches in milliseconds. Minimal delay is 100 ms. Will always be respected!rw
MilliSecond
.1.3.6.1.4.1.31034.12.1.1.2.5.1.1.5
sdbDevStPowerSaverModeSet backlight on time in seconds. 0 keeps display always on. Note that keeping the backlight on may decrease luminosity over time.rw
Second (0 | 10 | 60 | 120 | 240) UNITS "s"
.1.3.6.1.4.1.31034.12.1.1.2.5.1.1.6
sdbDevStOutletPowerUpModeBehaviour of outlets on power-up.rw
Enumeration
.1.3.6.1.4.1.31034.12.1.1.2.5.1.1.7
sdbDevStMaximumTemperatureMaximum temperature threshold An alert will be generated whenever the temperature is above this value. Zero means disabled.rw
Integer32
.1.3.6.1.4.1.31034.12.1.1.2.5.1.1.8
sdbDevStDisplayOrientationDisplay orientation.rw
Enumeration
.1.3.6.1.4.1.31034.12.1.1.2.5.1.1.9
sdbDevStLocalAlertResetAllow alerts to be reset locally on device by pushing one of the buttons.rw
Enumeration
.1.3.6.1.4.1.31034.12.1.1.2.5.1.1.10
sdbDevStCurrentDropDetectionEnables the current drop detection function.rw
Enumeration
.1.3.6.1.4.1.31034.12.1.1.2.5.1.1.11
sdbDevInput
OBJECT IDENTIFIER
.1.3.6.1.4.1.31034.12.1.1.2.6
sdbDevInTableA table containing information of inputs of devices connected to the databus.
SEQUENCE OF SdbDevInEntry
.1.3.6.1.4.1.31034.12.1.1.2.6.1
sdbDevInEntryInputs entry containing objects of an input of a particular databus device. Note that this table has two indexes. sdbDevIdIndex to identify a particular device and sdbDevInIndex to identify a particular input of the device identified by sdbDevIdIndex.
SdbDevInEntry
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1
sdbDevInIndexA unique value for each input. Its value ranges between 1 and the value of sdbDevCfPhases.
Integer32
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.1
sdbDevInKWhTotalTotal kWh value of an input. This value can not be reset.ro
KiloWattHour UNITS "kWh"
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.2
sdbDevInKWhSubtotalSubtotal kWh value of an input. This value can be reset.ro
KiloWattHour UNITS "kWh"
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.3
sdbDevInPowerFactorPower factor of input. The power factor of an AC power system is defined as the ratio of the real or active power to the apparent power and is a number between 0 and 1. This value is expressed as a percentage between 0% and 100%.ro
DeciPercent UNITS "%"
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.4
sdbDevInActualCurrentActual apparent, RMS current.ro
DeciAmpere UNITS "A"
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.5
sdbDevInPeakCurrentPeak apparent, RMS current. Highest value since last reset of the alerts.ro
DeciAmpere UNITS "A"
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.6
sdbDevInActualVoltageThe actual voltage.ro
DeciVolt UNITS "V"
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.7
sdbDevInMinVoltageRMS voltage dip. Lowest value since reset of alerts.ro
DeciVolt UNITS "V"
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.8
sdbDevInPowerVoltAmpereCalculated apparent power.ro
Integer32
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.9
sdbDevInPowerWattCalculated real power.ro
Integer32
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.10
sdbDevInMaxAmpsMaximum current per input phase. Should last at least sdbDevStPeakDuration ms before triggering an alert.rw
DeciAmpere UNITS "A"
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.11
sdbDevInCTRatioThe multiplier to use for the input CTs.rw
Integer32
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.12
sdbDevInNameUser configurable naming of inputs or phases.rw
DisplayString
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.13
sdbDevInZeroKWhSubtotalReset input kWh subtotal counter of a single input to zero.rw
Enumeration
.1.3.6.1.4.1.31034.12.1.1.2.6.1.1.14
sdbDevOutlet
OBJECT IDENTIFIER
.1.3.6.1.4.1.31034.12.1.1.2.7
sdbDevOutTableA table containing information of outlets of devices connected to the databus.
SEQUENCE OF SdbDevOutEntry
.1.3.6.1.4.1.31034.12.1.1.2.7.1
sdbDevOutEntryOutlets entry containing objects of an outlet of a particular databus device. Note that this table has two indexes. sdbDevIdIndex to identify a particular device and sdbDevOutIndex to identify a particular outlet of the device identified by sdbDevIdIndex.
SdbDevOutEntry
.1.3.6.1.4.1.31034.12.1.1.2.7.1.1
sdbDevOutIndexA unique value for each outlet. Its value ranges between 1 and the value of sdbDevCfOutletsTotal.
Integer32
.1.3.6.1.4.1.31034.12.1.1.2.7.1.1.1
sdbDevOutNameUser configurable naming of individual outlets.rw
DisplayString
.1.3.6.1.4.1.31034.12.1.1.2.7.1.1.2
sdbDevOutMtTableA table containing information of metered outlets of devices connected to the databus.
SEQUENCE OF SdbDevOutMtEntry
.1.3.6.1.4.1.31034.12.1.1.2.7.2
sdbDevOutMtEntryMetered outlets entry containing objects of a metered outlet of a particular databus device. Note that this table has two indexes. sdbDevIdIndex to identify a particular device and sdbDevOutMtIndex to identify a particular outlet of the device identified by sdbDevIdIndex.
SdbDevOutMtEntry
.1.3.6.1.4.1.31034.12.1.1.2.7.2.1
sdbDevOutMtIndexA unique value for each outlet. Its value ranges between 1 and the value of sdbDevCfOutletsMetered.
Integer32
.1.3.6.1.4.1.31034.12.1.1.2.7.2.1.1
sdbDevOutMtKWhTotalTotal kWh value of an outlet. This value can not be reset.ro
KiloWattHour UNITS "kWh"
.1.3.6.1.4.1.31034.12.1.1.2.7.2.1.2
sdbDevOutMtKWhSubtotalSubotal kWh value of an outlet. This value can be reset.ro
KiloWattHour UNITS "kWh"
.1.3.6.1.4.1.31034.12.1.1.2.7.2.1.3
sdbDevOutMtPowerFactorPower factor of outlet. The power factor of an AC power system is defined as the ratio of the real or active power to the apparent power and is a number between 0 and 1. This number is expressed as a percentage between 0% and 100%.ro
DeciPercent UNITS "%"
.1.3.6.1.4.1.31034.12.1.1.2.7.2.1.4
sdbDevOutMtActualCurrentActual apparent, RMS current.ro
DeciAmpere UNITS "A"
.1.3.6.1.4.1.31034.12.1.1.2.7.2.1.5
sdbDevOutMtPeakCurrentPeak apparent, RMS current. Highest value since last reset of the alerts.ro
DeciAmpere UNITS "A"
.1.3.6.1.4.1.31034.12.1.1.2.7.2.1.6
sdbDevOutMtActualVoltageActual voltage on outlet.ro
DeciVolt UNITS "V"
.1.3.6.1.4.1.31034.12.1.1.2.7.2.1.7
sdbDevOutMtMaxAmpsMaximum current per outlet. Should last at least sdbDevStPeakDuration ms before triggering an alert.rw
DeciAmpere UNITS "A"
.1.3.6.1.4.1.31034.12.1.1.2.7.2.1.8
sdbDevOutMtCTRatioThe multiplier to use for the outlet CTs.rw
Integer32
.1.3.6.1.4.1.31034.12.1.1.2.7.2.1.9
sdbDevOutMtPowerVoltAmpereCalculated apparent power.ro
Integer32
.1.3.6.1.4.1.31034.12.1.1.2.7.2.1.10
sdbDevOutMtPowerWattCalculated real power.ro
Integer32
.1.3.6.1.4.1.31034.12.1.1.2.7.2.1.11
sdbDevOutSwTableA table containing information of switched outlets of devices connected to the databus.
SEQUENCE OF SdbDevOutSwEntry
.1.3.6.1.4.1.31034.12.1.1.2.7.3
sdbDevOutSwEntrySwitched outlets entry containing objects of a switched outlet of a particular databus device. Note that this table has two indexes. sdbDevIdIndex to identify a particular device and sdbDevOutSwIndex to identify a particular outlet of the device identified by sdbDevIdIndex.
SdbDevOutSwEntry
.1.3.6.1.4.1.31034.12.1.1.2.7.3.1
sdbDevOutSwIndexA unique value for each outlet. Its value ranges between 1 and the value of sdbDevCfOutletsSwitched.
Integer32
.1.3.6.1.4.1.31034.12.1.1.2.7.3.1.1
sdbDevOutSwCurrentStateThe actual state of the outlet relay. Note that Writing is only effective after setting sdbDevOutSwUnlock.rw
Enumeration
.1.3.6.1.4.1.31034.12.1.1.2.7.3.1.2
sdbDevOutSwScheduledA one indicates pending activity; the switch delay has not yet expired.ro
Enumeration
.1.3.6.1.4.1.31034.12.1.1.2.7.3.1.3
sdbDevOutSwUnlockSwitching and rebooting is unlocked for 10 seconds by writing a 1.rw
Enumeration
.1.3.6.1.4.1.31034.12.1.1.2.7.3.1.4
sdbDevOutSwIndividualOutletDelayDelay before an individual outlet switches on at power-up.rw
Second
.1.3.6.1.4.1.31034.12.1.1.2.7.3.1.5
sdbDevOutSwRebootReboot outlet relay if current state is on and outlet is unlocked; The outlet will be turned on after 10 seconds.rw
Enumeration
.1.3.6.1.4.1.31034.12.1.1.2.7.3.1.6
sdbDevSensor
OBJECT IDENTIFIER
.1.3.6.1.4.1.31034.12.1.1.2.8
sdbDevMeasuresTableA table containing information of temperatures of devices connected to the databus.
SEQUENCE OF SdbDevMeasuresEntry
.1.3.6.1.4.1.31034.12.1.1.2.8.1
sdbDevMeasuresEntryDevice measures entry containing temperature information objects of a particular databus device.
SdbDevMeasuresEntry
.1.3.6.1.4.1.31034.12.1.1.2.8.1.1
sdbDevMsIntTemperatureActual internal device temperature in deg Cro
DeciCelsius UNITS "degrees Celsius"
.1.3.6.1.4.1.31034.12.1.1.2.8.1.1.1
sdbDevMsExtTemperatureActual external device temperature sensor in deg C.ro
DeciCelsius UNITS "degrees Celsius"
.1.3.6.1.4.1.31034.12.1.1.2.8.1.1.2
sdbDevMsIntTemperaturePeakPeak internal device temperature since last reset of alerts.ro
DeciCelsius UNITS "degrees Celsius"
.1.3.6.1.4.1.31034.12.1.1.2.8.1.1.3
sdbDevMsExtTemperaturePeakPeak external device temperature since last reset of alerts.ro
DeciCelsius UNITS "degrees Celsius"
.1.3.6.1.4.1.31034.12.1.1.2.8.1.1.4
sdbDevSnsTableA table containing information of sensors of devices connected to the databus.
SEQUENCE OF SdbDevSnsEntry
.1.3.6.1.4.1.31034.12.1.1.2.8.2
sdbDevSnsEntrySensors entry containing objects of a sensor of a particular databus device. Note that this table has two indexes. sdbDevIdIndex to identify a particular device and sdbDevSnsIndex to identify a particular sensor of the device identified by sdbDevIdIndex.
SdbDevSnsEntry
.1.3.6.1.4.1.31034.12.1.1.2.8.2.1
sdbDevSnsIndexA unique value for each sensor. Its value ranges between 1 and the value of sdbDevCfSensors.
Integer32
.1.3.6.1.4.1.31034.12.1.1.2.8.2.1.1
sdbDevSnsTypeType of connected sensor. T = Temperature (C) H = Humidity (%) I = dry switch contactro
DisplayString
.1.3.6.1.4.1.31034.12.1.1.2.8.2.1.2
sdbDevSnsValueValue of connected sensorro
DeciValue
.1.3.6.1.4.1.31034.12.1.1.2.8.2.1.3
sdbDevSnsNameUser definable name for sensors.rw
DisplayString
.1.3.6.1.4.1.31034.12.1.1.2.8.2.1.4
sdbMIBConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.31034.12.1.2
sdbMIBCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.31034.12.1.2.1
sdbMIBComplianceThe requirements for conformance to the SCHLEIFENBAUER-DATABUS-MIB.
Unknown
.1.3.6.1.4.1.31034.12.1.2.1.1
sdbMIBGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.31034.12.1.2.2
sdbMIBNotificationGroupA collection of notifications.
Unknown
.1.3.6.1.4.1.31034.12.1.2.2.1
sdbMIBDevIdGroupA collection of objects providing identification information about the device.
Unknown
.1.3.6.1.4.1.31034.12.1.2.2.3
sdbMIBDevCfGroupA collection of objects providing configuration information about the device.
Unknown
.1.3.6.1.4.1.31034.12.1.2.2.4
sdbMIBDevSsGroupA collection of objects providing status information about the device.
Unknown
.1.3.6.1.4.1.31034.12.1.2.2.5
sdbMIBDevRsGroupGroups resettable attributes op the device.
Unknown
.1.3.6.1.4.1.31034.12.1.2.2.6
sdbMIBDevStGroupA collection of objects providing the actual settings about the device.
Unknown
.1.3.6.1.4.1.31034.12.1.2.2.7
sdbMIBDevInGroupA collection of objects providing the actual input measurements of the device.
Unknown
.1.3.6.1.4.1.31034.12.1.2.2.8
sdbMIBDevOutGroupA collection of objects providing the actual outlet measurements of the device.
Unknown
.1.3.6.1.4.1.31034.12.1.2.2.9
sdbMIBDevOutMtGroupA collection of objects providing the actual outlet measurements of the device.
Unknown
.1.3.6.1.4.1.31034.12.1.2.2.10
sdbMIBDevOutSwGroupA collection of objects providing the actual outlet measurements of the device.
Unknown
.1.3.6.1.4.1.31034.12.1.2.2.11
sdbMIBDevSensorGroupA collection of objects providing the actual environmental measurements of the device.
Unknown
.1.3.6.1.4.1.31034.12.1.2.2.12
sdbMIBMgmtStatusGroupA collection of objects providing management status information about the databus.
Unknown
.1.3.6.1.4.1.31034.12.1.2.2.13
sdbMIBMgmtControlGroupA collection of objects providing management control information about the databus.
Unknown
.1.3.6.1.4.1.31034.12.1.2.2.14