RS366-OPT-MIB
Detailed view of the defined objects, syntax rules, and hierarchical paths.
32
Objects
Active
Status
2
Dependencies
Imported Objects
Objects
32 total| Object Name |
|---|
codex OBJECT IDENTIFIER .1.3.6.1.4.1.449 |
RFC1155-SMI Unknown .1.3.6.1.4.1.449 |
cdxProductSpecific OBJECT IDENTIFIER .1.3.6.1.4.1.449.2 |
cdx6500 OBJECT IDENTIFIER .1.3.6.1.4.1.449.2.1 |
cdx6500Configuration OBJECT IDENTIFIER .1.3.6.1.4.1.449.2.1.2 |
cdx6500CfgProtocolGroup OBJECT IDENTIFIER .1.3.6.1.4.1.449.2.1.2.1 |
cdx6500PCTPortProtocolGroup OBJECT IDENTIFIER .1.3.6.1.4.1.449.2.1.2.1.1 |
cdx6500PPCTRS366PortTableA list of RS366 Port configuration entries. SEQUENCE OF Cdx6500PPCTRS366PortEntry .1.3.6.1.4.1.449.2.1.2.1.1.21 |
cdx6500PPCTRS366PortEntryAn RS366 Configuration Table entry. Each entry
contains the configuration parameters for a single
RS366 port. Cdx6500PPCTRS366PortEntry .1.3.6.1.4.1.449.2.1.2.1.1.21.1 |
cdx6500RS366CfgPortNumberPort Number.ro INTEGER .1.3.6.1.4.1.449.2.1.2.1.1.21.1.1 |
cdx6500RS366CfgADataPortNumberAssociated Data Port Numberro INTEGER .1.3.6.1.4.1.449.2.1.2.1.1.21.1.2 |
cdx6500RS366CfgContXferModemodeEon - Transfer control after end of number digit detected.
modeEbt - Transfer control after maximum address digits
accumulated and answerback tone is received.
newvalModeNull - same functionality as 'modeNull', new enumeration
added for RFC1155 compatibility.ro Enumeration .1.3.6.1.4.1.449.2.1.2.1.1.21.1.3 |
cdx6500RS366CfgMaxAddrDigitsNumber of digits required to transfer control in EBT mode.
This parameter is not required in EON mode and it is set to
15 irrespective of the user entry.ro INTEGER .1.3.6.1.4.1.449.2.1.2.1.1.21.1.4 |
cdx6500RS366CfgMaxRespTimeMaximum EIA response time in seconds before a timeout
can occur.
sec0 - Indicates response time out should be disabled.
sec32 - Maximum EIA response time is 32 seconds.
sec48 - Maximum EIA response time is 48 seconds.
sec96 - Maximum EIA response time is 96 seconds.
newvalSec0 - same functionality as 'sec0', new enumeration
added for RFC1155 compatibility.ro Enumeration .1.3.6.1.4.1.449.2.1.2.1.1.21.1.5 |
cdx6500RS366CfgElectricalInterfaceTypeSpecify the Electrical Interface Type:
V.24 - V.24 Electrical Interface Type
V.35 - V.35 Electrical Interface Type
V.36 - V.36 Electrical Interface Type
X.21 - X.21 Electrical Interface Type
NONE - Electrically disabledro Enumeration .1.3.6.1.4.1.449.2.1.2.1.1.21.1.6 |
cdx6500RS366CfgV24ElectricalInterfaceOptionSpecify the Pin 22 option:
RI - V.24 uses Pin 22 for Ring Indicator output signal
TM - V.24 uses Pin 22 for Test Mode input signalro Enumeration .1.3.6.1.4.1.449.2.1.2.1.1.21.1.7 |
cdx6500RS366CfgHighSpeedElectricalInterfaceOptionSpecify the cable type:
NONE - V.35/V.36/X.21 DCE with straight through cable
XOVER - V.35/V.36/X.21 DCE with crossover adapter cablero Enumeration .1.3.6.1.4.1.449.2.1.2.1.1.21.1.8 |
cdx6500Statistics OBJECT IDENTIFIER .1.3.6.1.4.1.449.2.1.3 |
cdx6500StatProtocolGroup OBJECT IDENTIFIER .1.3.6.1.4.1.449.2.1.3.1 |
cdx6500PSTPortProtocolGroup OBJECT IDENTIFIER .1.3.6.1.4.1.449.2.1.3.1.1 |
cdx6500PPSTRS366PortTableA list of RS366 Port statistics. SEQUENCE OF Cdx6500PPSTRS366PortEntry .1.3.6.1.4.1.449.2.1.3.1.1.22 |
cdx6500PPSTRS366PortEntryAn RS366 Statistics Table entry. Each entry
contains the statistics for a single RS366 port. Cdx6500PPSTRS366PortEntry .1.3.6.1.4.1.449.2.1.3.1.1.22.1 |
cdx6500RS366StatPortNumberPort Number.ro INTEGER .1.3.6.1.4.1.449.2.1.3.1.1.22.1.1 |
cdx6500RS366StatPortStatusEnabled or Disabled.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.449.2.1.3.1.1.22.1.2 |
cdx6500RS366StatPortStatePort State.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.449.2.1.3.1.1.22.1.3 |
cdx6500RS366StatDataNumData Port Number.ro INTEGER .1.3.6.1.4.1.449.2.1.3.1.1.22.1.4 |
cdx6500RS366StatTotalCallsNumber of calls made.ro INTEGER .1.3.6.1.4.1.449.2.1.3.1.1.22.1.5 |
cdx6500RS366StatFailedCallsNumber of failed calls.ro INTEGER .1.3.6.1.4.1.449.2.1.3.1.1.22.1.6 |
cdx6500RS366StatTotalTimeoutsNumber of protocol time-outs.ro INTEGER .1.3.6.1.4.1.449.2.1.3.1.1.22.1.7 |
cdx6500RS366StatTotalIllegalDigitsNumber of illegal digits received.ro INTEGER .1.3.6.1.4.1.449.2.1.3.1.1.22.1.8 |
cdx6500RS366StatPortConnectedConnected to Data Port.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.449.2.1.3.1.1.22.1.9 |
cdx6500Controls OBJECT IDENTIFIER .1.3.6.1.4.1.449.2.1.4 |