Home/Catalog/RFC1382-MIB

RFC1382-MIB

Detailed view of the defined objects, syntax rules, and hierarchical paths.

171
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

171 total
Object Name
x25
OBJECT IDENTIFIER
.1.3.6.1.2.1.10.5
RFC1155-SMI
Unknown
.1.3.6.1.2.1.10.5
x25RestartThis trap means the X.25 PLE sent or received a restart packet. The restart that brings up the link should not send a x25Restart trap so the interface should send a linkUp trap. Sending this trap means the agent does not send a linkDown and linkUp trap.
TRAP-TYPE
.1.3.6.1.2.1.10.5.0.1
x25ResetIf the PLE sends or receives a reset, the agent should send an x25Reset trap.
TRAP-TYPE
.1.3.6.1.2.1.10.5.0.2
x25AdmnTableThis table contains the administratively set configuration parameters for an X.25 Packet Level Entity (PLE). Most of the objects in this table have corresponding objects in the x25OperTable. This table contains the values as last set by the administrator. The x25OperTable contains the values actually in use by an X.25 PLE. Changing an administrative value may or may not change a current operating value. The operating value may not change until the interface is restarted. Some implementations may change the values immediately upon changing the administrative table. All implementations are required to load the values from the administrative table when initializing a PLE.
SEQUENCE OF X25AdmnEntry
.1.3.6.1.2.1.10.5.1
x25AdmnEntryEntries of x25AdmnTable.
X25AdmnEntry
.1.3.6.1.2.1.10.5.1.1
x25AdmnIndexThe ifIndex value for the X.25 Interface.ro
IfIndexType
.1.3.6.1.2.1.10.5.1.1.1
x25AdmnInterfaceModeIdentifies DCE/DTE mode in which the interface operates. A value of dxe indicates the mode will be determined by XID negotiation.rw
Enumeration
.1.3.6.1.2.1.10.5.1.1.2
x25AdmnMaxActiveCircuitsThe maximum number of circuits this PLE can support; including PVCs.rw
INTEGER
.1.3.6.1.2.1.10.5.1.1.3
x25AdmnPacketSequencingThe modulus of the packet sequence number space.rw
Enumeration
.1.3.6.1.2.1.10.5.1.1.4
x25AdmnRestartTimerThe T20 restart timer in milliseconds.rw
PositiveInteger
.1.3.6.1.2.1.10.5.1.1.5
x25AdmnCallTimerThe T21 Call timer in milliseconds.rw
PositiveInteger
.1.3.6.1.2.1.10.5.1.1.6
x25AdmnResetTimerThe T22 Reset timer in milliseconds.rw
PositiveInteger
.1.3.6.1.2.1.10.5.1.1.7
x25AdmnClearTimerThe T23 Clear timer in milliseconds.rw
PositiveInteger
.1.3.6.1.2.1.10.5.1.1.8
x25AdmnWindowTimerThe T24 window status transmission timer in milliseconds. A value of 2147483647 indicates no window timer in use.rw
PositiveInteger
.1.3.6.1.2.1.10.5.1.1.9
x25AdmnDataRxmtTimerThe T25 data retransmission timer in milliseconds. A value of 2147483647 indicates no data retransmission timer in use.rw
PositiveInteger
.1.3.6.1.2.1.10.5.1.1.10
x25AdmnInterruptTimerThe T26 interrupt timer in milliseconds. A value of 2147483647 indicates no interrupt timer in use.rw
PositiveInteger
.1.3.6.1.2.1.10.5.1.1.11
x25AdmnRejectTimerThe T27 Reject retransmission timer in milliseconds. A value of 2147483647 indicates no reject timer in use.rw
PositiveInteger
.1.3.6.1.2.1.10.5.1.1.12
x25AdmnRegistrationRequestTimerThe T28 registration timer in milliseconds. A value of 2147483647 indicates no registration timer in use.rw
PositiveInteger
.1.3.6.1.2.1.10.5.1.1.13
x25AdmnMinimumRecallTimerMinimum time interval between unsuccessful call attempts in milliseconds.rw
PositiveInteger
.1.3.6.1.2.1.10.5.1.1.14
x25AdmnRestartCountThe R20 restart retransmission count.rw
INTEGER
.1.3.6.1.2.1.10.5.1.1.15
x25AdmnResetCountThe r22 Reset retransmission count.rw
INTEGER
.1.3.6.1.2.1.10.5.1.1.16
x25AdmnClearCountThe r23 Clear retransmission count.rw
INTEGER
.1.3.6.1.2.1.10.5.1.1.17
x25AdmnDataRxmtCountThe R25 Data retransmission count. This value is irrelevant if the x25AdmnDataRxmtTimer indicates no timer in use.rw
INTEGER
.1.3.6.1.2.1.10.5.1.1.18
x25AdmnRejectCountThe R27 reject retransmission count. This value is irrelevant if the x25AdmnRejectTimer indicates no timer in use.rw
INTEGER
.1.3.6.1.2.1.10.5.1.1.19
x25AdmnRegistrationRequestCountThe R28 Registration retransmission Count. This value is irrelevant if the x25AdmnRegistrationRequestTimer indicates no timer in use.rw
INTEGER
.1.3.6.1.2.1.10.5.1.1.20
x25AdmnNumberPVCsThe number of PVC configured for this PLE. The PVCs use channel numbers from 1 to this number.rw
INTEGER
.1.3.6.1.2.1.10.5.1.1.21
x25AdmnDefCallParamIdThis identifies the instance of the x25CallParmIndex for the entry in the x25CallParmTable which contains the default call parameters for this PLE.rw
OBJECT IDENTIFIER
.1.3.6.1.2.1.10.5.1.1.22
x25AdmnLocalAddressThe local address for this PLE subnetwork. A zero length address maybe returned by PLEs that only support PVCs.rw
X121Address
.1.3.6.1.2.1.10.5.1.1.23
x25AdmnProtocolVersionSupportedIdentifies the version of the X.25 protocol this interface should support. Object identifiers for common versions are defined below in the x25ProtocolVersion subtree.rw
OBJECT IDENTIFIER
.1.3.6.1.2.1.10.5.1.1.24
x25OperTableThe operation parameters in use by the X.25 PLE.
SEQUENCE OF X25OperEntry
.1.3.6.1.2.1.10.5.2
x25OperEntryEntries of x25OperTable.
X25OperEntry
.1.3.6.1.2.1.10.5.2.1
x25OperIndexThe ifIndex value for the X.25 interface.ro
IfIndexType
.1.3.6.1.2.1.10.5.2.1.1
x25OperInterfaceModeIdentifies DCE/DTE mode in which the interface operates. A value of dxe indicates the role will be determined by XID negotiation at the Link Layer and that negotiation has not yet taken place.ro
Enumeration
.1.3.6.1.2.1.10.5.2.1.2
x25OperMaxActiveCircuitsMaximum number of circuits this PLE can support.ro
INTEGER
.1.3.6.1.2.1.10.5.2.1.3
x25OperPacketSequencingThe modulus of the packet sequence number space.ro
Enumeration
.1.3.6.1.2.1.10.5.2.1.4
x25OperRestartTimerThe T20 restart timer in milliseconds.ro
PositiveInteger
.1.3.6.1.2.1.10.5.2.1.5
x25OperCallTimerThe T21 Call timer in milliseconds.ro
PositiveInteger
.1.3.6.1.2.1.10.5.2.1.6
x25OperResetTimerThe T22 Reset timer in milliseconds.ro
PositiveInteger
.1.3.6.1.2.1.10.5.2.1.7
x25OperClearTimerThe T23 Clear timer in milliseconds.ro
PositiveInteger
.1.3.6.1.2.1.10.5.2.1.8
x25OperWindowTimerThe T24 window status transmission timer milliseconds. A value of 2147483647 indicates no window timer in use.ro
PositiveInteger
.1.3.6.1.2.1.10.5.2.1.9
x25OperDataRxmtTimerThe T25 Data Retransmission timer in milliseconds. A value of 2147483647 indicates no data retransmission timer in use.ro
PositiveInteger
.1.3.6.1.2.1.10.5.2.1.10
x25OperInterruptTimerThe T26 Interrupt timer in milliseconds. A value of 2147483647 indicates interrupts are not being used.ro
PositiveInteger
.1.3.6.1.2.1.10.5.2.1.11
x25OperRejectTimerThe T27 Reject retransmission timer in milliseconds. A value of 2147483647 indicates no reject timer in use.ro
PositiveInteger
.1.3.6.1.2.1.10.5.2.1.12
x25OperRegistrationRequestTimerThe T28 registration timer in milliseconds. A value of 2147483647 indicates no registration timer in use.ro
PositiveInteger
.1.3.6.1.2.1.10.5.2.1.13
x25OperMinimumRecallTimerMinimum time interval between unsuccessful call attempts in milliseconds.ro
PositiveInteger
.1.3.6.1.2.1.10.5.2.1.14
x25OperRestartCountThe R20 restart retransmission count.ro
INTEGER
.1.3.6.1.2.1.10.5.2.1.15
x25OperResetCountThe r22 Reset retransmission count.ro
INTEGER
.1.3.6.1.2.1.10.5.2.1.16
x25OperClearCountThe r23 Clear retransmission count.ro
INTEGER
.1.3.6.1.2.1.10.5.2.1.17
x25OperDataRxmtCountThe R25 Data retransmission count. This value is undefined if the x25OperDataRxmtTimer indicates no timer in use.ro
INTEGER
.1.3.6.1.2.1.10.5.2.1.18
x25OperRejectCountThe R27 reject retransmission count. This value is undefined if the x25OperRejectTimer indicates no timer in use.ro
INTEGER
.1.3.6.1.2.1.10.5.2.1.19
x25OperRegistrationRequestCountThe R28 Registration retransmission Count. This value is undefined if the x25OperREgistrationRequestTimer indicates no timer in use.ro
INTEGER
.1.3.6.1.2.1.10.5.2.1.20
x25OperNumberPVCsThe number of PVC configured for this PLE. The PVCs use channel numbers from 1 to this number.ro
INTEGER
.1.3.6.1.2.1.10.5.2.1.21
x25OperDefCallParamIdThis identifies the instance of the x25CallParmIndex for the entry in the x25CallParmTable that contains the default call parameters for this PLE.ro
OBJECT IDENTIFIER
.1.3.6.1.2.1.10.5.2.1.22
x25OperLocalAddressThe local address for this PLE subnetwork. A zero length address maybe returned by PLEs that only support PVCs.ro
X121Address
.1.3.6.1.2.1.10.5.2.1.23
x25OperDataLinkIdThis identifies the instance of the index object in the first table of the most device specific MIB for the interface used by this PLE.ro
OBJECT IDENTIFIER
.1.3.6.1.2.1.10.5.2.1.24
x25OperProtocolVersionSupportedIdentifies the version of the X.25 protocol this interface supports. Object identifiers for common versions are defined below in the x25ProtocolVersion subtree.ro
OBJECT IDENTIFIER
.1.3.6.1.2.1.10.5.2.1.25
x25StatTableStatistics information about this X.25 PLE.
SEQUENCE OF X25StatEntry
.1.3.6.1.2.1.10.5.3
x25StatEntryEntries of the x25StatTable.
X25StatEntry
.1.3.6.1.2.1.10.5.3.1
x25StatIndexThe ifIndex value for the X.25 interface.ro
IfIndexType
.1.3.6.1.2.1.10.5.3.1.1
x25StatInCallsThe number of incoming calls received.ro
Counter
.1.3.6.1.2.1.10.5.3.1.2
x25StatInCallRefusalsThe number of incoming calls refused. This includes calls refused by the PLE and by higher layers. This also includes calls cleared because of restricted fast select.ro
Counter
.1.3.6.1.2.1.10.5.3.1.3
x25StatInProviderInitiatedClearsThe number of clear requests with a cause code other than DTE initiated.ro
Counter
.1.3.6.1.2.1.10.5.3.1.4
x25StatInRemotelyInitiatedResetsThe number of reset requests received with cause code DTE initiated.ro
Counter
.1.3.6.1.2.1.10.5.3.1.5
x25StatInProviderInitiatedResetsThe number of reset requests received with cause code other than DTE initiated.ro
Counter
.1.3.6.1.2.1.10.5.3.1.6
x25StatInRestartsThe number of remotely initiated (including provider initiated) restarts experienced by the PLE excluding the restart associated with bringing up the PLE interface. This only counts restarts received when the PLE already has an established connection with the remove PLE.ro
Counter
.1.3.6.1.2.1.10.5.3.1.7
x25StatInDataPacketsThe number of data packets received.ro
Counter
.1.3.6.1.2.1.10.5.3.1.8
x25StatInAccusedOfProtocolErrorsThe number of packets received containing a procedure error cause code. These include clear, reset, restart, or diagnostic packets.ro
Counter
.1.3.6.1.2.1.10.5.3.1.9
x25StatInInterruptsThe number of interrupt packets received by the PLE or over the PVC/VC.ro
Counter
.1.3.6.1.2.1.10.5.3.1.10
x25StatOutCallAttemptsThe number of calls attempted.ro
Counter
.1.3.6.1.2.1.10.5.3.1.11
x25StatOutCallFailuresThe number of call attempts which failed. This includes calls that were cleared because of restrictive fast select.ro
Counter
.1.3.6.1.2.1.10.5.3.1.12
x25StatOutInterruptsThe number of interrupt packets send by the PLE or over the PVC/VC.ro
Counter
.1.3.6.1.2.1.10.5.3.1.13
x25StatOutDataPacketsThe number of data packets sent by this PLE.ro
Counter
.1.3.6.1.2.1.10.5.3.1.14
x25StatOutgoingCircuitsThe number of active outgoing circuits. This includes call requests sent but not yet confirmed. This does not count PVCs.ro
Gauge
.1.3.6.1.2.1.10.5.3.1.15
x25StatIncomingCircuitsThe number of active Incoming Circuits. This includes call indications received but not yet acknowledged. This does not count PVCs.ro
Gauge
.1.3.6.1.2.1.10.5.3.1.16
x25StatTwowayCircuitsThe number of active two-way Circuits. This includes call requests sent but not yet confirmed. This does not count PVCs.ro
Gauge
.1.3.6.1.2.1.10.5.3.1.17
x25StatRestartTimeoutsThe number of times the T20 restart timer expired.ro
Counter
.1.3.6.1.2.1.10.5.3.1.18
x25StatCallTimeoutsThe number of times the T21 call timer expired.ro
Counter
.1.3.6.1.2.1.10.5.3.1.19
x25StatResetTimeoutsThe number of times the T22 reset timer expired.ro
Counter
.1.3.6.1.2.1.10.5.3.1.20
x25StatClearTimeoutsThe number of times the T23 clear timer expired.ro
Counter
.1.3.6.1.2.1.10.5.3.1.21
x25StatDataRxmtTimeoutsThe number of times the T25 data timer expired.ro
Counter
.1.3.6.1.2.1.10.5.3.1.22
x25StatInterruptTimeoutsThe number of times the T26 interrupt timer expired.ro
Counter
.1.3.6.1.2.1.10.5.3.1.23
x25StatRetryCountExceededsThe number of times a retry counter was exhausted.ro
Counter
.1.3.6.1.2.1.10.5.3.1.24
x25StatClearCountExceededsThe number of times the R23 clear count was exceeded.ro
Counter
.1.3.6.1.2.1.10.5.3.1.25
x25ChannelTableThese objects contain information about the channel number configuration in an X.25 PLE. These values are the configured values. changes in these values after the interfaces has started may not be reflected in the operating PLE.
SEQUENCE OF X25ChannelEntry
.1.3.6.1.2.1.10.5.4
x25ChannelEntryEntries of x25ChannelTable.
X25ChannelEntry
.1.3.6.1.2.1.10.5.4.1
x25ChannelIndexThe ifIndex value for the X.25 Interface.ro
IfIndexType
.1.3.6.1.2.1.10.5.4.1.1
x25ChannelLICLowest Incoming channel.rw
INTEGER
.1.3.6.1.2.1.10.5.4.1.2
x25ChannelHICHighest Incoming channel. A value of zero indicates no channels in this range.rw
INTEGER
.1.3.6.1.2.1.10.5.4.1.3
x25ChannelLTCLowest Two-way channel.rw
INTEGER
.1.3.6.1.2.1.10.5.4.1.4
x25ChannelHTCHighest Two-way channel. A value of zero indicates no channels in this range.rw
INTEGER
.1.3.6.1.2.1.10.5.4.1.5
x25ChannelLOCLowest outgoing channel.rw
INTEGER
.1.3.6.1.2.1.10.5.4.1.6
x25ChannelHOCHighest outgoing channel. A value of zero indicates no channels in this range.rw
INTEGER
.1.3.6.1.2.1.10.5.4.1.7
x25CircuitTableThese objects contain general information about a specific circuit of an X.25 PLE.
SEQUENCE OF X25CircuitEntry
.1.3.6.1.2.1.10.5.5
x25CircuitEntryEntries of x25CircuitTable.
X25CircuitEntry
.1.3.6.1.2.1.10.5.5.1
x25CircuitIndexThe ifIndex value for the X.25 Interface.ro
IfIndexType
.1.3.6.1.2.1.10.5.5.1.1
x25CircuitChannelThe channel number for this circuit.ro
INTEGER
.1.3.6.1.2.1.10.5.5.1.2
x25CircuitStatusThis object reports the current status of the circuit. An existing instance of this object can only be set to startClear, startPvcResetting, or invalid. An instance with the value calling or open can only be set to startClear and that action will start clearing the circuit. An instance with the value PVC can only be set to startPvcResetting or invalid and that action resets the PVC or deletes the circuit respectively. The values startClear or startPvcResetting will never be returned by an agent. An attempt to set the status of an existing instance to a value other than one of these values will result in an error. A non-existing instance can be set to PVC to create a PVC if the implementation supports dynamic creation of PVCs. Some implementations may only allow creation and deletion of PVCs if the interface is down. Since the instance identifier will supply the PLE index and the channel number, setting this object alone supplies sufficient information to create the instance. All the DEFVAL clauses for the other objects of this table are appropriate for creating a PVC; PLEs creating entries for placed or accepted calls will use values appropriate for the call rather than the value of the DEFVAL clause. Two managers trying to create the same PVC can determine from the return code which manager succeeded and which failed (the failing manager fails because it can not set a value of PVC for an existing object). An entry in the closed or invalid state may be deleted or reused at the agent's convence. If the entry is kept in the closed state, the values of the parameters associated with the entry must be correct. Closed implies the values in the circuit table are correct. The value of invalid indicates the other values in the table are invalid. Many agents may never return a value of invalid because they dynamically allocate and free unused table entries. An agent for a statically configured systems can return invalid to indicate the entry has not yet been used so the counters contain no information.rw
Enumeration
.1.3.6.1.2.1.10.5.5.1.3
x25CircuitEstablishTimeThe value of sysUpTime when the channel was associated with this circuit. For outgoing SVCs, this is the time the first call packet was sent. For incoming SVCs, this is the time the call indication was received. For PVCs this is the time the PVC was able to pass data to a higher layer entity without loss of data.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.2.1.10.5.5.1.4
x25CircuitDirectionThe direction of the call that established this circuit.rw
Enumeration
.1.3.6.1.2.1.10.5.5.1.5
x25CircuitInOctetsThe number of octets of user data delivered to upper layer.ro
Counter
.1.3.6.1.2.1.10.5.5.1.6
x25CircuitInPdusThe number of PDUs received for this circuit.ro
Counter
.1.3.6.1.2.1.10.5.5.1.7
x25CircuitInRemotelyInitiatedResetsThe number of Resets received for this circuit with cause code of DTE initiated.ro
Counter
.1.3.6.1.2.1.10.5.5.1.8
x25CircuitInProviderInitiatedResetsThe number of Resets received for this circuit with cause code other than DTE initiated.ro
Counter
.1.3.6.1.2.1.10.5.5.1.9
x25CircuitInInterruptsThe number of interrupt packets received for this circuit.ro
Counter
.1.3.6.1.2.1.10.5.5.1.10
x25CircuitOutOctetsThe number of octets of user data sent for this circuit.ro
Counter
.1.3.6.1.2.1.10.5.5.1.11
x25CircuitOutPdusThe number of PDUs sent for this circuit.ro
Counter
.1.3.6.1.2.1.10.5.5.1.12
x25CircuitOutInterruptsThe number of interrupt packets sent on this circuit.ro
Counter
.1.3.6.1.2.1.10.5.5.1.13
x25CircuitDataRetransmissionTimeoutsThe number of times the T25 data retransmission timer expired for this circuit.ro
Counter
.1.3.6.1.2.1.10.5.5.1.14
x25CircuitResetTimeoutsThe number of times the T22 reset timer expired for this circuit.ro
Counter
.1.3.6.1.2.1.10.5.5.1.15
x25CircuitInterruptTimeoutsThe number of times the T26 Interrupt timer expired for this circuit.ro
Counter
.1.3.6.1.2.1.10.5.5.1.16
x25CircuitCallParamIdThis identifies the instance of the x25CallParmIndex for the entry in the x25CallParmTable which contains the call parameters in use with this circuit. The entry referenced must contain the values that are currently in use by the circuit rather than proposed values. A value of NULL indicates the circuit is a PVC or is using all the default parameters.rw
OBJECT IDENTIFIER
.1.3.6.1.2.1.10.5.5.1.17
x25CircuitCalledDteAddressFor incoming calls, this is the called address from the call indication packet. For outgoing calls, this is the called address from the call confirmation packet. This will be zero length for PVCs.rw
X121Address
.1.3.6.1.2.1.10.5.5.1.18
x25CircuitCallingDteAddressFor incoming calls, this is the calling address from the call indication packet. For outgoing calls, this is the calling address from the call confirmation packet. This will be zero length for PVCs.rw
X121Address
.1.3.6.1.2.1.10.5.5.1.19
x25CircuitOriginallyCalledAddressFor incoming calls, this is the address in the call Redirection or Call Deflection Notification facility if the call was deflected or redirected, otherwise it will be called address from the call indication packet. For outgoing calls, this is the address from the call request packet. This will be zero length for PVCs.rw
X121Address
.1.3.6.1.2.1.10.5.5.1.20
x25CircuitDescrA descriptive string associated with this circuit. This provides a place for the agent to supply any descriptive information it knows about the use or owner of the circuit. The agent may return the process identifier and user name for the process using the circuit. Alternative the agent may return the name of the configuration entry that caused a bridge to establish the circuit. A zero length value indicates the agent doesn't have any additional information.rw
DisplayString
.1.3.6.1.2.1.10.5.5.1.21
x25ClearedCircuitEntriesRequestedThe requested number of entries for the agent to keep in the x25ClearedCircuit table.rw
PositiveInteger
.1.3.6.1.2.1.10.5.6
x25ClearedCircuitEntriesGrantedThe actual number of entries the agent will keep in the x25ClearedCircuit Table.ro
PositiveInteger
.1.3.6.1.2.1.10.5.7
x25ClearedCircuitTableA table of entries about closed circuits. Entries must be made in this table whenever circuits are closed and the close request or close indication packet contains a clearing cause other than DTE Originated or a Diagnostic code field other than Higher Layer Initiated disconnection-normal. An agent may optionally make entries for normal closes (to record closing facilities or other information). Agents will delete the oldest entry in the table when adding a new entry would exceed agent resources. Agents are required to keep the last entry put in the table and may keep more entries. The object x25OperClearEntriesGranted returns the maximum number of entries kept in the table.
SEQUENCE OF X25ClearedCircuitEntry
.1.3.6.1.2.1.10.5.8
x25ClearedCircuitEntryInformation about a cleared circuit.
X25ClearedCircuitEntry
.1.3.6.1.2.1.10.5.8.1
x25ClearedCircuitIndexAn index that uniquely distinguishes one entry in the clearedCircuitTable from another. This index will start at 2147483647 and will decrease by one for each new entry added to the table. Upon reaching one, the index will reset to 2147483647. Because the index starts at 2147483647 and decreases, a manager may do a getnext on entry zero and obtain the most recent entry. When the index has the value of 1, the next entry will delete all entries in the table and that entry will be numbered 2147483647.ro
PositiveInteger
.1.3.6.1.2.1.10.5.8.1.1
x25ClearedCircuitPleIndexThe value of ifIndex for the PLE which cleared the circuit that created the entry.ro
IfIndexType
.1.3.6.1.2.1.10.5.8.1.2
x25ClearedCircuitTimeEstablishedThe value of sysUpTime when the circuit was established. This will be the same value that was in the x25CircuitEstablishTime for the circuit.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.2.1.10.5.8.1.3
x25ClearedCircuitTimeClearedThe value of sysUpTime when the circuit was cleared. For locally initiated clears, this will be the time when the clear confirmation was received. For remotely initiated clears, this will be the time when the clear indication was received.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.2.1.10.5.8.1.4
x25ClearedCircuitChannelThe channel number for the circuit that was cleared.ro
INTEGER
.1.3.6.1.2.1.10.5.8.1.5
x25ClearedCircuitClearingCauseThe Clearing Cause from the clear request or clear indication packet that cleared the circuit.ro
INTEGER
.1.3.6.1.2.1.10.5.8.1.6
x25ClearedCircuitDiagnosticCodeThe Diagnostic Code from the clear request or clear indication packet that cleared the circuit.ro
INTEGER
.1.3.6.1.2.1.10.5.8.1.7
x25ClearedCircuitInPdusThe number of PDUs received on the circuit.ro
Counter
.1.3.6.1.2.1.10.5.8.1.8
x25ClearedCircuitOutPdusThe number of PDUs transmitted on the circuit.ro
Counter
.1.3.6.1.2.1.10.5.8.1.9
x25ClearedCircuitCalledAddressThe called address from the cleared circuit.ro
X121Address
.1.3.6.1.2.1.10.5.8.1.10
x25ClearedCircuitCallingAddressThe calling address from the cleared circuit.ro
X121Address
.1.3.6.1.2.1.10.5.8.1.11
x25ClearedCircuitClearFacilitiesThe facilities field from the clear request or clear indication packet that cleared the circuit. A size of zero indicates no facilities were present.ro
OCTET STRING
.1.3.6.1.2.1.10.5.8.1.12
x25CallParmTableThese objects contain the parameters that can be varied between X.25 calls. The entries in this table are independent of the PLE. There exists only one of these tables for the entire system. The indexes for the entries are independent of any PLE or any circuit. Other tables reference entries in this table. Entries in this table can be used for default PLE parameters, for parameters to use to place/answer a call, for the parameters currently in use for a circuit, or parameters that were used by a circuit. The number of references to a given set of parameters can be found in the x25CallParmRefCount object sharing the same instance identifier with the parameters. The value of this reference count also affects the access of the objects in this table. An object in this table with the same instance identifier as the instance identifier of an x25CallParmRefCount must be consider associated with that reference count. An object with an associated reference count of zero can be written (if its ACCESS clause allows it). An object with an associated reference count greater than zero can not be written (regardless of the ACCESS clause). This ensures that a set of call parameters being referenced from another table can not be modified or changed in a ways inappropriate for continued use by that table.
SEQUENCE OF X25CallParmEntry
.1.3.6.1.2.1.10.5.9
x25CallParmEntryEntries of x25CallParmTable.
X25CallParmEntry
.1.3.6.1.2.1.10.5.9.1
x25CallParmIndexA value that distinguishes this entry from another entry. Entries in this table are referenced from other objects which identify call parameters. It is impossible to know which other objects in the MIB reference entries in the table by looking at this table. Because of this, changes to parameters must be accomplished by creating a new entry in this table and then changing the referencing table to identify the new entry. Note that an agent will only use the values in this table when another table is changed to reference those values. The number of other tables that reference an index object in this table can be found in x25CallParmRefCount. The value of the reference count will affect the writability of the objects as explained above. Entries in this table which have a reference count of zero maybe deleted at the convence of the agent. Care should be taken by the agent to give the NMS sufficient time to create a reference to newly created entries. Should a Management Station not find a free index with which to create a new entry, it may feel free to delete entries with a reference count of zero. However in doing so the Management Station much realize it may impact other Management Stations.ro
PositiveInteger
.1.3.6.1.2.1.10.5.9.1.1
x25CallParmStatusThe status of this call parameter entry. See RFC 1271 for details of usage.rw
EntryStatus
.1.3.6.1.2.1.10.5.9.1.2
x25CallParmRefCountThe number of references know by a management station to exist to this set of call parameters. This is the number of other objects that have returned a value of, and will return a value of, the index for this set of call parameters. Examples of such objects are the x25AdmnDefCallParamId, x25OperDataLinkId, or x25AdmnDefCallParamId objects defined above.ro
PositiveInteger
.1.3.6.1.2.1.10.5.9.1.3
x25CallParmInPacketSizeThe maximum receive packet size in octets for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE means use a default size of 128.rw
INTEGER
.1.3.6.1.2.1.10.5.9.1.4
x25CallParmOutPacketSizeThe maximum transmit packet size in octets for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE default means use a default size of 128.rw
INTEGER
.1.3.6.1.2.1.10.5.9.1.5
x25CallParmInWindowSizeThe receive window size for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE default means use 2.rw
INTEGER
.1.3.6.1.2.1.10.5.9.1.6
x25CallParmOutWindowSizeThe transmit window size for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE default means use 2.rw
INTEGER
.1.3.6.1.2.1.10.5.9.1.7
x25CallParmAcceptReverseChargingAn enumeration defining if the PLE will accept or refuse charges. A value of default for a circuit means use the PLE default value. A value of neverAccept is only used for the PLE default and indicates the PLE will never accept reverse charging. A value of default for a PLE default means refuse.rw
Enumeration
.1.3.6.1.2.1.10.5.9.1.8
x25CallParmProposeReverseChargingAn enumeration defining if the PLE should propose reverse or local charging. The value of default for a circuit means use the PLE default. The value of default for the PLE default means use local.rw
Enumeration
.1.3.6.1.2.1.10.5.9.1.9
x25CallParmFastSelectExpresses preference for use of fast select facility. The value of default for a circuit is the PLE default. A value of default for the PLE means noFastSelect. A value of noFastSelect or noRestrictedFastResponse indicates a circuit may not use fast select or restricted fast response.rw
Enumeration
.1.3.6.1.2.1.10.5.9.1.10
x25CallParmInThruPutClasSizeThe incoming throughput class to negotiate. A value of tcDefault for a circuit means use the PLE default. A value of tcDefault for the PLE default means tcNone. A value of tcNone means do not negotiate throughtput class.rw
Enumeration
.1.3.6.1.2.1.10.5.9.1.11
x25CallParmOutThruPutClasSizeThe outgoing throughput class to negotiate. A value of tcDefault for a circuit means use the PLE default. A value of tcDefault for the PLE default means use tcNone. A value of tcNone means do not negotiate throughtput class.rw
Enumeration
.1.3.6.1.2.1.10.5.9.1.12
x25CallParmCugThe Closed User Group to specify. This consists of two or four octets containing the characters 0 through 9. A zero length string indicates no facility requested. A string length of three containing the characters DEF for a circuit means use the PLE default, (the PLE default parameter may not reference an entry of DEF.)rw
DisplayString
.1.3.6.1.2.1.10.5.9.1.13
x25CallParmCugoaThe Closed User Group with Outgoing Access to specify. This consists of two or four octets containing the characters 0 through 9. A string length of three containing the characters DEF for a circuit means use the PLE default (the PLE default parameters may not reference an entry of DEF). A zero length string indicates no facility requested.rw
DisplayString
.1.3.6.1.2.1.10.5.9.1.14
x25CallParmBcugThe Bilateral Closed User Group to specify. This consists of two octets containing the characters 0 through 9. A string length of three containing the characters DEF for a circuit means use the PLE default (the PLE default parameter may not reference an entry of DEF). A zero length string indicates no facility requested.rw
DisplayString
.1.3.6.1.2.1.10.5.9.1.15
x25CallParmNuiThe Network User Identifier facility. This is binary value to be included immediately after the length field. The PLE will supply the length octet. A zero length string indicates no facility requested. This value is ignored for the PLE default parameters entry.rw
OCTET STRING
.1.3.6.1.2.1.10.5.9.1.16
x25CallParmChargingInfoThe charging Information facility. A value of default for a circuit means use the PLE default. The value of default for the default PLE parameters means use noFacility. The value of noFacility means do not include a facility.rw
Enumeration
.1.3.6.1.2.1.10.5.9.1.17
x25CallParmRpoaThe RPOA facility. The octet string contains n * 4 sequences of the characters 0-9 to specify a facility with n entries. The octet string containing the 3 characters DEF for a circuit specifies use of the PLE default (the entry for the PLE default may not contain DEF). A zero length string indicates no facility requested.rw
DisplayString
.1.3.6.1.2.1.10.5.9.1.18
x25CallParmTrnstDlyThe Transit Delay Selection and Indication value. A value of 65536 indicates no facility requested. A value of 65537 for a circuit means use the PLE default (the PLE default parameters entry may not use the value 65537). The value 65535 may only be used to indicate the value in use by a circuit.rw
INTEGER
.1.3.6.1.2.1.10.5.9.1.19
x25CallParmCallingExtThe Calling Extension facility. This contains one of the following: A sequence of hex digits with the value to be put in the facility. These digits will be converted to binary by the agent and put in the facility. These octets do not include the length octet. A value containing the three character DEF for a circuit means use the PLE default, (the entry for the PLE default parameters may not use the value DEF). A zero length string indicates no facility requested.rw
DisplayString
.1.3.6.1.2.1.10.5.9.1.20
x25CallParmCalledExtThe Called Extension facility. This contains one of the following: A sequence of hex digits with the value to be put in the facility. These digits will be converted to binary by the agent and put in the facility. These octets do not include the length octet. A value containing the three character DEF for a circuit means use the PLE default, (the entry for the PLE default parameters may not use the value DEF). A zero length string indicates no facility requested.rw
DisplayString
.1.3.6.1.2.1.10.5.9.1.21
x25CallParmInMinThuPutClsThe minimum input throughput Class. A value of 16 for a circuit means use the PLE default (the PLE parameters entry may not use this value). A value of 17 indicates no facility requested.rw
INTEGER
.1.3.6.1.2.1.10.5.9.1.22
x25CallParmOutMinThuPutClsThe minimum output throughput Class. A value of 16 for a circuit means use the PLE default (the PLE parameters entry may not use this value). A value of 17 indicates no facility requested.rw
INTEGER
.1.3.6.1.2.1.10.5.9.1.23
x25CallParmEndTrnsDlyThe End-to-End Transit Delay to negotiate. An octet string of length 2, 4, or 6 contains the facility encoded as specified in ISO/IEC 8208 section 15.3.2.4. An octet string of length 3 containing the three character DEF for a circuit means use the PLE default (the entry for the PLE default can not contain the characters DEF). A zero length string indicates no facility requested.rw
OCTET STRING
.1.3.6.1.2.1.10.5.9.1.24
x25CallParmPriorityThe priority facility to negotiate. The octet string encoded as specified in ISO/IEC 8208 section 15.3.2.5. A zero length string indicates no facility requested. The entry for the PLE default parameters must be zero length.rw
OCTET STRING
.1.3.6.1.2.1.10.5.9.1.25
x25CallParmProtectionA string contains the following: A hex string containing the value for the protection facility. This will be converted from hex to the octets actually in the packet by the agent. The agent will supply the length field and the length octet is not contained in this string. An string containing the 3 characters DEF for a circuit means use the PLE default (the entry for the PLE default parameters may not use the value DEF). A zero length string mean no facility requested.rw
DisplayString
.1.3.6.1.2.1.10.5.9.1.26
x25CallParmExptDataThe Expedited Data facility to negotiate. A value of default for a circuit means use the PLE default value. The entry for the PLE default parameters may not have the value default.rw
Enumeration
.1.3.6.1.2.1.10.5.9.1.27
x25CallParmUserDataThe call user data as placed in the packet. A zero length string indicates no call user data. If both the circuit call parameters and the PLE default have call user data defined, the data from the circuit call parameters will be used. If only the PLE has data defined, the PLE entry will be used. If neither the circuit call parameters or the PLE default entry has a value, no call user data will be sent.rw
OCTET STRING
.1.3.6.1.2.1.10.5.9.1.28
x25CallParmCallingNetworkFacilitiesThe calling network facilities. The facilities are encoded here exactly as encoded in the call packet. These facilities do not include the marker facility code. A zero length string in the entry for the parameter to use when establishing a circuit means use the PLE default. A zero length string in the entry for PLE default parameters indicates no default facilities.rw
OCTET STRING
.1.3.6.1.2.1.10.5.9.1.29
x25CallParmCalledNetworkFacilitiesThe called network facilities. The facilities are encoded here exactly as encoded in the call packet. These facilities do not include the marker facility code. A zero length string in the entry for the parameter to use when establishing a circuit means use the PLE default. A zero length string in the entry for PLE default parameters indicates no default facilities.rw
OCTET STRING
.1.3.6.1.2.1.10.5.9.1.30
x25ProtocolVersion
OBJECT IDENTIFIER
.1.3.6.1.2.1.10.5.10
x25protocolCcittV1976
OBJECT IDENTIFIER
.1.3.6.1.2.1.10.5.10.1
x25protocolCcittV1980
OBJECT IDENTIFIER
.1.3.6.1.2.1.10.5.10.2
x25protocolCcittV1984
OBJECT IDENTIFIER
.1.3.6.1.2.1.10.5.10.3
x25protocolCcittV1988
OBJECT IDENTIFIER
.1.3.6.1.2.1.10.5.10.4
x25protocolIso8208V1987
OBJECT IDENTIFIER
.1.3.6.1.2.1.10.5.10.5
x25protocolIso8208V1989
OBJECT IDENTIFIER
.1.3.6.1.2.1.10.5.10.6
RFC1382-MIB - SNMP MIB Reference | MIBs Explorer