Home/Catalog/RFC1231-MIB

RFC1231-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for RFC1231-MIB.

41
Objects
Active
Status
3
Dependencies

Imported Objects

Objects

41 total
Object Name
transmission
OBJECT IDENTIFIER
.1.3.6.1.2.1.10
RFC1213-MIB
Unknown
.1.3.6.1.2.1.10
dot5
OBJECT IDENTIFIER
.1.3.6.1.2.1.10.9
dot5TableThis table contains Token Ring interface parameters and state variables, one entry per 802.5 interface.
SEQUENCE OF Dot5Entry
.1.3.6.1.2.1.10.9.1
dot5EntryA list of Token Ring status and parameter values for an 802.5 interface.
Dot5Entry
.1.3.6.1.2.1.10.9.1.1
dot5IfIndexThe value of this object identifies the 802.5 interface for which this entry contains management information. The value of this object for a particular interface has the same value as the ifIndex object, defined in [4,6], for the same interface.ro
INTEGER
.1.3.6.1.2.1.10.9.1.1.1
dot5CommandsWhen this object is set to the value of open(2), the station should go into the open state. The progress and success of the open is given by the values of the objects dot5RingState and dot5RingOpenStatus. When this object is set to the value of reset(3), then the station should do a reset. On a reset, all MIB counters should retain their values, if possible. Other side affects are dependent on the hardware chip set. When this object is set to the value of close(4), the station should go into the stopped state by removing itself from the ring. Setting this object to a value of no-op(1) has no effect. When read, this object always has a value of no-op(1).rw
Enumeration
.1.3.6.1.2.1.10.9.1.1.2
dot5RingStatusThe current interface status which can be used to diagnose fluctuating problems that can occur on token rings, after a station has successfully been added to the ring. Before an open is completed, this object has the value for the 'no status' condition. The dot5RingState and dot5RingOpenStatus objects provide for debugging problems when the station can not even enter the ring. The object's value is a sum of values, one for each currently applicable condition. The following values are defined for various conditions: 0 = No Problems detected 32 = Ring Recovery 64 = Single Station 256 = Remove Received 512 = reserved 1024 = Auto-Removal Error 2048 = Lobe Wire Fault 4096 = Transmit Beacon 8192 = Soft Error 16384 = Hard Error 32768 = Signal Loss 131072 = no status, open not completed.ro
INTEGER
.1.3.6.1.2.1.10.9.1.1.3
dot5RingStateThe current interface state with respect to entering or leaving the ring.ro
Enumeration
.1.3.6.1.2.1.10.9.1.1.4
dot5RingOpenStatusThis object indicates the success, or the reason for failure, of the station's most recent attempt to enter the ring.ro
Enumeration
.1.3.6.1.2.1.10.9.1.1.5
dot5RingSpeedThe ring's bandwidth.rw
Enumeration
.1.3.6.1.2.1.10.9.1.1.6
dot5UpStreamThe MAC-address of the up stream neighbor station in the ring.ro
MacAddress (SNMPv2-TC)
.1.3.6.1.2.1.10.9.1.1.7
dot5ActMonParticipateIf this object has a value of true(1) then this interface will participate in the active monitor selection process. If the value is false(2) then it will not. Setting this object might not have an effect until the next time the interface is opened.rw
Enumeration
.1.3.6.1.2.1.10.9.1.1.8
dot5FunctionalThe bit mask of all Token Ring functional addresses for which this interface will accept frames.rw
MacAddress (SNMPv2-TC)
.1.3.6.1.2.1.10.9.1.1.9
dot5StatsTableA table containing Token Ring statistics, one entry per 802.5 interface. All the statistics are defined using the syntax Counter as 32-bit wrap around counters. Thus, if an interface's hardware maintains these statistics in 16-bit counters, then the agent must read the hardware's counters frequently enough to prevent loss of significance, in order to maintain 32-bit counters in software.
SEQUENCE OF Dot5StatsEntry
.1.3.6.1.2.1.10.9.2
dot5StatsEntryAn entry contains the 802.5 statistics for a particular interface.
Dot5StatsEntry
.1.3.6.1.2.1.10.9.2.1
dot5StatsIfIndexThe value of this object identifies the 802.5 interface for which this entry contains management information. The value of this object for a particular interface has the same value as the ifIndex object, defined in [4,6], for the same interface.ro
INTEGER
.1.3.6.1.2.1.10.9.2.1.1
dot5StatsLineErrorsThis counter is incremented when a frame or token is copied or repeated by a station, the E bit is zero in the frame or token and one of the following conditions exists: 1) there is a non-data bit (J or K bit) between the SD and the ED of the frame or token, or 2) there is an FCS error in the frame.ro
Counter
.1.3.6.1.2.1.10.9.2.1.2
dot5StatsBurstErrorsThis counter is incremented when a station detects the absence of transitions for five half-bit timers (burst-five error).ro
Counter
.1.3.6.1.2.1.10.9.2.1.3
dot5StatsACErrorsThis counter is incremented when a station receives an AMP or SMP frame in which A is equal to C is equal to 0, and then receives another SMP frame with A is equal to C is equal to 0 without first receiving an AMP frame. It denotes a station that cannot set the AC bits properly.ro
Counter
.1.3.6.1.2.1.10.9.2.1.4
dot5StatsAbortTransErrorsThis counter is incremented when a station transmits an abort delimiter while transmitting.ro
Counter
.1.3.6.1.2.1.10.9.2.1.5
dot5StatsInternalErrorsThis counter is incremented when a station recognizes an internal error.ro
Counter
.1.3.6.1.2.1.10.9.2.1.6
dot5StatsLostFrameErrorsThis counter is incremented when a station is transmitting and its TRR timer expires. This condition denotes a condition where a transmitting station in strip mode does not receive the trailer of the frame before the TRR timer goes off.ro
Counter
.1.3.6.1.2.1.10.9.2.1.7
dot5StatsReceiveCongestionsThis counter is incremented when a station recognizes a frame addressed to its specific address, but has no available buffer space indicating that the station is congested.ro
Counter
.1.3.6.1.2.1.10.9.2.1.8
dot5StatsFrameCopiedErrorsThis counter is incremented when a station recognizes a frame addressed to its specific address and detects that the FS field A bits are set to 1 indicating a possible line hit or duplicate address.ro
Counter
.1.3.6.1.2.1.10.9.2.1.9
dot5StatsTokenErrorsThis counter is incremented when a station acting as the active monitor recognizes an error condition that needs a token transmitted.ro
Counter
.1.3.6.1.2.1.10.9.2.1.10
dot5StatsSoftErrorsThe number of Soft Errors the interface has detected. It directly corresponds to the number of Report Error MAC frames that this interface has transmitted. Soft Errors are those which are recoverable by the MAC layer protocols.ro
Counter
.1.3.6.1.2.1.10.9.2.1.11
dot5StatsHardErrorsThe number of times this interface has detected an immediately recoverable fatal error. It denotes the number of times this interface is either transmitting or receiving beacon MAC frames.ro
Counter
.1.3.6.1.2.1.10.9.2.1.12
dot5StatsSignalLossThe number of times this interface has detected the loss of signal condition from the ring.ro
Counter
.1.3.6.1.2.1.10.9.2.1.13
dot5StatsTransmitBeaconsThe number of times this interface has transmitted a beacon frame.ro
Counter
.1.3.6.1.2.1.10.9.2.1.14
dot5StatsRecoverysThe number of Claim Token MAC frames received or transmitted after the interface has received a Ring Purge MAC frame. This counter signifies the number of times the ring has been purged and is being recovered back into a normal operating state.ro
Counter
.1.3.6.1.2.1.10.9.2.1.15
dot5StatsLobeWiresThe number of times the interface has detected an open or short circuit in the lobe data path. The adapter will be closed and dot5RingState will signify this condition.ro
Counter
.1.3.6.1.2.1.10.9.2.1.16
dot5StatsRemovesThe number of times the interface has received a Remove Ring Station MAC frame request. When this frame is received the interface will enter the close state and dot5RingState will signify this condition.ro
Counter
.1.3.6.1.2.1.10.9.2.1.17
dot5StatsSinglesThe number of times the interface has sensed that it is the only station on the ring. This will happen if the interface is the first one up on a ring, or if there is a hardware problem.ro
Counter
.1.3.6.1.2.1.10.9.2.1.18
dot5StatsFreqErrorsThe number of times the interface has detected that the frequency of the incoming signal differs from the expected frequency by more than that specified by the IEEE 802.5 standard, see chapter 7 in [10].ro
Counter
.1.3.6.1.2.1.10.9.2.1.19
dot5Tests
OBJECT IDENTIFIER
.1.3.6.1.2.1.10.9.3
testInsertFunc
OBJECT IDENTIFIER
.1.3.6.1.2.1.10.9.3.1
dot5ChipSets
OBJECT IDENTIFIER
.1.3.6.1.2.1.10.9.4
chipSetIBM16
OBJECT IDENTIFIER
.1.3.6.1.2.1.10.9.4.1
chipSetTItms380
OBJECT IDENTIFIER
.1.3.6.1.2.1.10.9.4.2
chipSetTItms380c16
OBJECT IDENTIFIER
.1.3.6.1.2.1.10.9.4.3