READYNAS-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for READYNAS-MIB.
75
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
75 total| Object Name |
|---|
netgear OBJECT IDENTIFIER .1.3.6.1.4.1.4526 |
IMPORTS Unknown .1.3.6.1.4.1.4526 |
nasManager OBJECT IDENTIFIER .1.3.6.1.4.1.4526.18 |
nasMgrSoftwareVersionVersion information for the ReadyNAS NAS
Manager software.ro DisplayString .1.3.6.1.4.1.4526.18.1 |
diskTableA table of physical disks attached to the NAS device. SEQUENCE OF DiskEntry .1.3.6.1.4.1.4526.18.3 |
diskEntryAn entry in the physical disk table. DiskEntry .1.3.6.1.4.1.4526.18.3.1 |
diskNumberInstance number of the disk entry.ro INTEGER .1.3.6.1.4.1.4526.18.3.1.1 |
diskChannelChannel number that the disk is connected to.ro INTEGER .1.3.6.1.4.1.4526.18.3.1.2 |
diskModelThe disk drive's model name.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.3.1.3 |
diskStateThe current state of the Disk.
Possible states:
0: Online
1: Offlinero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.3.1.4 |
diskTemperaturetemperature of this disk.ro INTEGER .1.3.6.1.4.1.4526.18.3.1.5 |
fanTable SEQUENCE OF FanEntry .1.3.6.1.4.1.4526.18.4 |
fanEntry FanEntry .1.3.6.1.4.1.4526.18.4.1 |
fanNumberInstance number of this fan entry.ro INTEGER .1.3.6.1.4.1.4526.18.4.1.1 |
fanRPMThe current speed of the fan.ro INTEGER .1.3.6.1.4.1.4526.18.4.1.2 |
fanTypeWhat fan is used for:
SYS: for system board
CPU: for CPU
CAS: for system casero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.4.1.3 |
temperatureTable SEQUENCE OF TemperatureEntry .1.3.6.1.4.1.4526.18.5 |
temperatureEntry TemperatureEntry .1.3.6.1.4.1.4526.18.5.1 |
temperatureNumberInstance number of this temperature probe entry.ro INTEGER .1.3.6.1.4.1.4526.18.5.1.1 |
temperatureValueThe current temperature of this probe.ro INTEGER .1.3.6.1.4.1.4526.18.5.1.2 |
temperatureStatusThe current temperature status.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.5.1.3 |
volumeTableA table of active volumes on the NAS device. SEQUENCE OF VolumeEntry .1.3.6.1.4.1.4526.18.7 |
volumeEntryAn entry in the volume table. VolumeEntry .1.3.6.1.4.1.4526.18.7.1 |
volumeNumberInstance number of the volume entry.ro INTEGER .1.3.6.1.4.1.4526.18.7.1.1 |
volumeNameThe name of the volume.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.7.1.2 |
volumeRAIDLevelThe RAID level of the volume.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.7.1.3 |
volumeStatusThe severity of the volume.
Possible values:
1: Clean
2: Error
16: Initialized (Normal)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.7.1.4 |
volumeSizeThe size of the volume in megabytes.ro INTEGER .1.3.6.1.4.1.4526.18.7.1.5 |
volumeFreeSpaceFree space on the volume in megabytes.ro INTEGER .1.3.6.1.4.1.4526.18.7.1.6 |
psuTable SEQUENCE OF PSUEntry .1.3.6.1.4.1.4526.18.8 |
psuEntry PSUEntry .1.3.6.1.4.1.4526.18.8.1 |
psuNumberInstance number of this power supply unit.ro INTEGER .1.3.6.1.4.1.4526.18.8.1.1 |
psuDescThe description of this PSU.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.8.1.2 |
psuStatusThe current PSU status.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.8.1.3 |
aryMgrEvts OBJECT IDENTIFIER .1.3.6.1.4.1.4526.18.200 |
controllerNameEvController Name for which trap is generated.ro DisplayString .1.3.6.1.4.1.4526.18.200.201 |
channelNumberEvChannel Number for which trap is generated.ro INTEGER .1.3.6.1.4.1.4526.18.200.202 |
targetIDEvSCSI ID of the device for which trap is generated.ro INTEGER .1.3.6.1.4.1.4526.18.200.203 |
virtualDiskNameEvVirtual Disk for which trap is generated.ro DisplayString .1.3.6.1.4.1.4526.18.200.204 |
arrayDiskNameEvArray Disk for which trap is generated.ro DisplayString .1.3.6.1.4.1.4526.18.200.205 |
oldVDConfigEvCurrent Virtual Disk configuration for which trap is generatedro DisplayString .1.3.6.1.4.1.4526.18.200.206 |
newVDConfigEvNew Virtual Disk configuration for which trap is generated.ro DisplayString .1.3.6.1.4.1.4526.18.200.207 |
enclosureNumberEvEnclosure Number for which trap is generated.ro INTEGER .1.3.6.1.4.1.4526.18.200.208 |
unitNumberEvUnit Number for which trap is generated.
(Fan, Power Supply, Temperature Probe)ro INTEGER .1.3.6.1.4.1.4526.18.200.209 |
enclosureNameEvEnclosure Name for which trap is generated.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.200.210 |
unitNameEvUnit Number for which trap is generated.
(Fan, Power Supply, Temperature Probe)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.200.211 |
timeEvAmount of time specified in the trap message.ro INTEGER .1.3.6.1.4.1.4526.18.200.212 |
volumeNameEvVolume Drive Letter for which trap is generated.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.200.213 |
nasTraps OBJECT IDENTIFIER .1.3.6.1.4.1.4526.18.300 |
fanFailureFan failure, fan speed is %s. TRAP-TYPE .1.3.6.1.4.1.4526.18.300.0.10 |
tempFailureTemperature sensor reports out of normal
range. TRAP-TYPE .1.3.6.1.4.1.4526.18.300.0.20 |
powerVoltageSystem power is out of spec, please check
system status! TRAP-TYPE .1.3.6.1.4.1.4526.18.300.0.30 |
raidEventNoticeRAID event detected! TRAP-TYPE .1.3.6.1.4.1.4526.18.300.0.40 |
snapshotEventNoticeSnapshot event detected! TRAP-TYPE .1.3.6.1.4.1.4526.18.300.0.50 |
hotplugDiskNoticeHotplug disk event detected! TRAP-TYPE .1.3.6.1.4.1.4526.18.300.0.60 |
upsEventNoticeUPS status. TRAP-TYPE .1.3.6.1.4.1.4526.18.300.0.70 |
volumeNoticeVolume is approaching capacity. TRAP-TYPE .1.3.6.1.4.1.4526.18.300.0.80 |
diskTempWarningDisk temperature warning. TRAP-TYPE .1.3.6.1.4.1.4526.18.300.0.90 |
backupNoticeBackup job status. TRAP-TYPE .1.3.6.1.4.1.4526.18.300.0.100 |
diskSmartWarningDisk SMART warning. TRAP-TYPE .1.3.6.1.4.1.4526.18.300.0.110 |
psuWarningPower supply unit warning. TRAP-TYPE .1.3.6.1.4.1.4526.18.300.0.120 |
fanFailureMesgFailure message for Fanro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.400 |
tempFailureMesgFailure message for system temperaturero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.401 |
powerFailureMesgFailure message for system powerro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.402 |
raidMesgRAID hotplug event messagero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.403 |
snapshotMesgSnapshot messagesro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.404 |
upsMesgUPS status messagero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.405 |
sataMesgSATA hotplug event messagesro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.406 |
volumeMesgDisk usage warningro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.407 |
diskTempWarningMesgDisk temperature warning messagesro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.408 |
backupMesgBackup job status messagesro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.409 |
smartMesgDisk SMART messagesro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.410 |
psuMesgPSU status messagesro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.411 |
productID OBJECT IDENTIFIER .1.3.6.1.4.1.4526.100 |
readyNAS OBJECT IDENTIFIER .1.3.6.1.4.1.4526.100.12 |