READYNAS-MIB
Standard SNMP MIB module defining data structures for READYNAS-MIB.
Imported Objects
Objects
75 total| Object Name |
|---|
netgear OBJECT IDENTIFIER .1.3.6.1.4.1.4526 |
IMPORTS Unknown .1.3.6.1.4.1.4526 |
nasManager OBJECT IDENTIFIER .1.3.6.1.4.1.4526.18 |
nasMgrSoftwareVersionVersion information for the ReadyNAS NAS
Manager software.ro DisplayString .1.3.6.1.4.1.4526.18.1 |
diskTableA table of physical disks attached to the NAS device. SEQUENCE OF DiskEntry .1.3.6.1.4.1.4526.18.3 |
diskEntryAn entry in the physical disk table. DiskEntry .1.3.6.1.4.1.4526.18.3.1 |
diskNumberInstance number of the disk entry.ro INTEGER .1.3.6.1.4.1.4526.18.3.1.1 |
diskChannelChannel number that the disk is connected to.ro INTEGER .1.3.6.1.4.1.4526.18.3.1.2 |
diskModelThe disk drive's model name.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.3.1.3 |
diskStateThe current state of the Disk.
Possible states:
0: Online
1: Offlinero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.3.1.4 |
diskTemperaturetemperature of this disk.ro INTEGER .1.3.6.1.4.1.4526.18.3.1.5 |
fanTable SEQUENCE OF FanEntry .1.3.6.1.4.1.4526.18.4 |
fanEntry FanEntry .1.3.6.1.4.1.4526.18.4.1 |
fanNumberInstance number of this fan entry.ro INTEGER .1.3.6.1.4.1.4526.18.4.1.1 |
fanRPMThe current speed of the fan.ro INTEGER .1.3.6.1.4.1.4526.18.4.1.2 |
fanTypeWhat fan is used for:
SYS: for system board
CPU: for CPU
CAS: for system casero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.4.1.3 |
temperatureTable SEQUENCE OF TemperatureEntry .1.3.6.1.4.1.4526.18.5 |
temperatureEntry TemperatureEntry .1.3.6.1.4.1.4526.18.5.1 |
temperatureNumberInstance number of this temperature probe entry.ro INTEGER .1.3.6.1.4.1.4526.18.5.1.1 |
temperatureValueThe current temperature of this probe.ro INTEGER .1.3.6.1.4.1.4526.18.5.1.2 |
temperatureStatusThe current temperature status.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.5.1.3 |
volumeTableA table of active volumes on the NAS device. SEQUENCE OF VolumeEntry .1.3.6.1.4.1.4526.18.7 |
volumeEntryAn entry in the volume table. VolumeEntry .1.3.6.1.4.1.4526.18.7.1 |
volumeNumberInstance number of the volume entry.ro INTEGER .1.3.6.1.4.1.4526.18.7.1.1 |
volumeNameThe name of the volume.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.7.1.2 |
volumeRAIDLevelThe RAID level of the volume.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.7.1.3 |
volumeStatusThe severity of the volume.
Possible values:
1: Clean
2: Error
16: Initialized (Normal)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.7.1.4 |
volumeSizeThe size of the volume in megabytes.ro INTEGER .1.3.6.1.4.1.4526.18.7.1.5 |
volumeFreeSpaceFree space on the volume in megabytes.ro INTEGER .1.3.6.1.4.1.4526.18.7.1.6 |
psuTable SEQUENCE OF PSUEntry .1.3.6.1.4.1.4526.18.8 |
psuEntry PSUEntry .1.3.6.1.4.1.4526.18.8.1 |
psuNumberInstance number of this power supply unit.ro INTEGER .1.3.6.1.4.1.4526.18.8.1.1 |
psuDescThe description of this PSU.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.8.1.2 |
psuStatusThe current PSU status.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.8.1.3 |
aryMgrEvts OBJECT IDENTIFIER .1.3.6.1.4.1.4526.18.200 |
controllerNameEvController Name for which trap is generated.ro DisplayString .1.3.6.1.4.1.4526.18.200.201 |
channelNumberEvChannel Number for which trap is generated.ro INTEGER .1.3.6.1.4.1.4526.18.200.202 |
targetIDEvSCSI ID of the device for which trap is generated.ro INTEGER .1.3.6.1.4.1.4526.18.200.203 |
virtualDiskNameEvVirtual Disk for which trap is generated.ro DisplayString .1.3.6.1.4.1.4526.18.200.204 |
arrayDiskNameEvArray Disk for which trap is generated.ro DisplayString .1.3.6.1.4.1.4526.18.200.205 |
oldVDConfigEvCurrent Virtual Disk configuration for which trap is generatedro DisplayString .1.3.6.1.4.1.4526.18.200.206 |
newVDConfigEvNew Virtual Disk configuration for which trap is generated.ro DisplayString .1.3.6.1.4.1.4526.18.200.207 |
enclosureNumberEvEnclosure Number for which trap is generated.ro INTEGER .1.3.6.1.4.1.4526.18.200.208 |
unitNumberEvUnit Number for which trap is generated.
(Fan, Power Supply, Temperature Probe)ro INTEGER .1.3.6.1.4.1.4526.18.200.209 |
enclosureNameEvEnclosure Name for which trap is generated.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.200.210 |
unitNameEvUnit Number for which trap is generated.
(Fan, Power Supply, Temperature Probe)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.200.211 |
timeEvAmount of time specified in the trap message.ro INTEGER .1.3.6.1.4.1.4526.18.200.212 |
volumeNameEvVolume Drive Letter for which trap is generated.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.200.213 |
nasTraps OBJECT IDENTIFIER .1.3.6.1.4.1.4526.18.300 |
fanFailureFan failure, fan speed is %s. TRAP-TYPE .1.3.6.1.4.1.4526.18.300.0.10 |
tempFailureTemperature sensor reports out of normal
range. TRAP-TYPE .1.3.6.1.4.1.4526.18.300.0.20 |
powerVoltageSystem power is out of spec, please check
system status! TRAP-TYPE .1.3.6.1.4.1.4526.18.300.0.30 |
raidEventNoticeRAID event detected! TRAP-TYPE .1.3.6.1.4.1.4526.18.300.0.40 |
snapshotEventNoticeSnapshot event detected! TRAP-TYPE .1.3.6.1.4.1.4526.18.300.0.50 |
hotplugDiskNoticeHotplug disk event detected! TRAP-TYPE .1.3.6.1.4.1.4526.18.300.0.60 |
upsEventNoticeUPS status. TRAP-TYPE .1.3.6.1.4.1.4526.18.300.0.70 |
volumeNoticeVolume is approaching capacity. TRAP-TYPE .1.3.6.1.4.1.4526.18.300.0.80 |
diskTempWarningDisk temperature warning. TRAP-TYPE .1.3.6.1.4.1.4526.18.300.0.90 |
backupNoticeBackup job status. TRAP-TYPE .1.3.6.1.4.1.4526.18.300.0.100 |
diskSmartWarningDisk SMART warning. TRAP-TYPE .1.3.6.1.4.1.4526.18.300.0.110 |
psuWarningPower supply unit warning. TRAP-TYPE .1.3.6.1.4.1.4526.18.300.0.120 |
fanFailureMesgFailure message for Fanro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.400 |
tempFailureMesgFailure message for system temperaturero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.401 |
powerFailureMesgFailure message for system powerro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.402 |
raidMesgRAID hotplug event messagero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.403 |
snapshotMesgSnapshot messagesro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.404 |
upsMesgUPS status messagero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.405 |
sataMesgSATA hotplug event messagesro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.406 |
volumeMesgDisk usage warningro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.407 |
diskTempWarningMesgDisk temperature warning messagesro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.408 |
backupMesgBackup job status messagesro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.409 |
smartMesgDisk SMART messagesro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.410 |
psuMesgPSU status messagesro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.18.411 |
productID OBJECT IDENTIFIER .1.3.6.1.4.1.4526.100 |
readyNAS OBJECT IDENTIFIER .1.3.6.1.4.1.4526.100.12 |
More MIBs from Netgear
Browse all NetgearMIBs →Standard SNMP MIB module defining data structures for WING-MIB.
The FASTPATH-SWITCHING-MIB enables monitoring and management of Netgear FastPath switching hardware, specifically exposing metrics related to Layer 2 forwarding tables, MAC address aging, VLAN configurations, and port statistics. This private MIB facilitates the tracking of switching plane performance and state changes within Netgear's proprietary FastPath operating environment.
The NETGEAR-SMART-SWITCHING-MIB provides vendor-specific OID extensions for monitoring and managing Layer 2 switching functions, including port status, MAC address tables, VLAN configurations, and spanning tree states on Netgear Smart Switches. This private MIB enables network management systems to retrieve granular operational data and control parameters specific to Netgear's proprietary switching firmware that are not covered by standard IEEE MIBs.
The NETGEAR-SWITCHING-MIB provides vendor-specific extensions for monitoring and managing Layer 2 switching functions on Netgear network switches, including port status, MAC address table entries, and VLAN configurations. It enables SNMP-based retrieval of proprietary switching metrics not covered by standard IETF MIBs to facilitate granular fault isolation and traffic analysis within Netgear-managed infrastructure.
SNMP MIB module
Standard SNMP MIB module defining data structures for GSM7312-SWITCHING-MIB.