READYDATAOS-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for READYDATAOS-MIB.
83
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
83 total| Object Name |
|---|
netgear OBJECT IDENTIFIER .1.3.6.1.4.1.4526 |
IMPORTS Unknown .1.3.6.1.4.1.4526 |
ngNasManager OBJECT IDENTIFIER .1.3.6.1.4.1.4526.22 |
nasMgrSoftwareVersionVersion information for the ReadyDATAOS
ngNasManager software.ro DisplayString .1.3.6.1.4.1.4526.22.1 |
diskTableA table of physical disks attached to the storage device. SEQUENCE OF DiskEntry .1.3.6.1.4.1.4526.22.3 |
diskEntryAn entry in the physical disk table. DiskEntry .1.3.6.1.4.1.4526.22.3.1 |
diskNumberInstance number of the disk entry.ro INTEGER .1.3.6.1.4.1.4526.22.3.1.1 |
diskIDDisk ID.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.22.3.1.2 |
diskSlotNameThe slot location of the disk.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.22.3.1.3 |
diskSerialDisk Serial number.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.22.3.1.4 |
diskModelThe disk drive's model name.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.22.3.1.5 |
ataErrorATA error number for this disk from S.M.A.R.T read.ro INTEGER .1.3.6.1.4.1.4526.22.3.1.6 |
diskCapacityThe capacity of the disk in bytes.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.22.3.1.7 |
diskInterfaceThe disk connect interface, such as SATA, USB etc.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.22.3.1.8 |
diskStateThe current state of the Disk.
Possible states:
0: Online
1: Offlinero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.22.3.1.9 |
diskTemperaturetemperature of this disk(in Fahrenheit unit).ro INTEGER .1.3.6.1.4.1.4526.22.3.1.10 |
fanTable SEQUENCE OF FanEntry .1.3.6.1.4.1.4526.22.4 |
fanEntry FanEntry .1.3.6.1.4.1.4526.22.4.1 |
fanNumberInstance number of this fan entry.ro INTEGER .1.3.6.1.4.1.4526.22.4.1.1 |
fanRPMThe current speed of the fan.ro INTEGER .1.3.6.1.4.1.4526.22.4.1.2 |
fanStatusThe status of Fanro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.22.4.1.3 |
fanTypeWhat fan is used for:
SYS: for system board
CPU: for CPU
CASE: for system casero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.22.4.1.4 |
temperatureTable SEQUENCE OF TemperatureEntry .1.3.6.1.4.1.4526.22.5 |
temperatureEntry TemperatureEntry .1.3.6.1.4.1.4526.22.5.1 |
temperatureNumberInstance number of this temperature probe entry.ro INTEGER .1.3.6.1.4.1.4526.22.5.1.1 |
temperatureValueThe current temperature of this probe (in Fahrenheit unit).ro INTEGER .1.3.6.1.4.1.4526.22.5.1.2 |
temperatureTyoeThe current temperature refer toro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.22.5.1.3 |
temperatureMinThe min temperature of this probe (in Fahrenheit unit).ro INTEGER .1.3.6.1.4.1.4526.22.5.1.4 |
temperatureMaxThe max temperature of this probe (in Fahrenheit unit).ro INTEGER .1.3.6.1.4.1.4526.22.5.1.5 |
volumeTableA table of active volumes on the storage device. SEQUENCE OF VolumeEntry .1.3.6.1.4.1.4526.22.7 |
volumeEntryAn entry in the volume table. VolumeEntry .1.3.6.1.4.1.4526.22.7.1 |
volumeNumberInstance number of the volume entry.ro INTEGER .1.3.6.1.4.1.4526.22.7.1.1 |
volumeNameThe name of the volume.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.22.7.1.2 |
volumeRAIDLevelThe RAID level of the volume.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.22.7.1.3 |
volumeStatusThe severity of the volume.
Possible values:
1: ONLINE
2: OFFLINE
3: DEGRADED
4: FAULTED
5: REMOVED
6: UNAVAILABLE
7: UNKNOWNro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.22.7.1.4 |
volumeSizeThe size of the volume in megabytes.ro INTEGER .1.3.6.1.4.1.4526.22.7.1.5 |
volumeFreeSpaceFree space on the volume in megabytes.ro INTEGER .1.3.6.1.4.1.4526.22.7.1.6 |
psuTable SEQUENCE OF PSUEntry .1.3.6.1.4.1.4526.22.8 |
psuEntryro PSUEntry .1.3.6.1.4.1.4526.22.8.1 |
psuNumberInstance number of this power supply unit.ro INTEGER .1.3.6.1.4.1.4526.22.8.1.1 |
psuDescThe description of this PSU.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.22.8.1.2 |
psuStatusThe current PSU status.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.22.8.1.3 |
aryMgrEvts OBJECT IDENTIFIER .1.3.6.1.4.1.4526.22.200 |
controllerNameEvController Name for which trap is generated.ro DisplayString .1.3.6.1.4.1.4526.22.200.201 |
channelNumberEvChannel Number for which trap is generated.ro INTEGER .1.3.6.1.4.1.4526.22.200.202 |
targetIDEvSCSI ID of the device for which trap is generated.ro INTEGER .1.3.6.1.4.1.4526.22.200.203 |
virtualDiskNameEvVirtual Disk for which trap is generated.ro DisplayString .1.3.6.1.4.1.4526.22.200.204 |
arrayDiskNameEvArray Disk for which trap is generated.ro DisplayString .1.3.6.1.4.1.4526.22.200.205 |
oldVDConfigEvCurrent Virtual Disk configuration for which trap is generatedro DisplayString .1.3.6.1.4.1.4526.22.200.206 |
newVDConfigEvNew Virtual Disk configuration for which trap is generated.ro DisplayString .1.3.6.1.4.1.4526.22.200.207 |
enclosureNumberEvEnclosure Number for which trap is generated.ro INTEGER .1.3.6.1.4.1.4526.22.200.208 |
unitNumberEvUnit Number for which trap is generated.
(Fan, Power Supply, Temperature Probe)ro INTEGER .1.3.6.1.4.1.4526.22.200.209 |
enclosureNameEvEnclosure Name for which trap is generated.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.22.200.210 |
unitNameEvUnit Number for which trap is generated.
(Fan, Power Supply, Temperature Probe)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.22.200.211 |
timeEvAmount of time specified in the trap message.ro INTEGER .1.3.6.1.4.1.4526.22.200.212 |
volumeNameEvVolume Drive Letter for which trap is generated.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.22.200.213 |
nasTraps OBJECT IDENTIFIER .1.3.6.1.4.1.4526.22.300 |
fanFailureFan failure, fan speed is %s. TRAP-TYPE .1.3.6.1.4.1.4526.22.300.0.10 |
tempFailureTemperature sensor reports out of normal range. TRAP-TYPE .1.3.6.1.4.1.4526.22.300.0.20 |
powerVoltageSystem power is out of spec, please check system status! TRAP-TYPE .1.3.6.1.4.1.4526.22.300.0.30 |
raidEventNoticeRAID event detected! TRAP-TYPE .1.3.6.1.4.1.4526.22.300.0.40 |
snapshotEventNoticeSnapshot event detected! TRAP-TYPE .1.3.6.1.4.1.4526.22.300.0.50 |
hotplugDiskNoticeHotplug disk event detected! TRAP-TYPE .1.3.6.1.4.1.4526.22.300.0.60 |
upsEventNoticeUPS status. TRAP-TYPE .1.3.6.1.4.1.4526.22.300.0.70 |
volumeNoticeVolume is approaching capacity. TRAP-TYPE .1.3.6.1.4.1.4526.22.300.0.80 |
diskTempWarningDisk temperature warning. TRAP-TYPE .1.3.6.1.4.1.4526.22.300.0.90 |
backupNoticeBackup job status. TRAP-TYPE .1.3.6.1.4.1.4526.22.300.0.100 |
diskSmartWarningDisk SMART warning. TRAP-TYPE .1.3.6.1.4.1.4526.22.300.0.110 |
psuWarningPower supply unit warning. TRAP-TYPE .1.3.6.1.4.1.4526.22.300.0.120 |
fanFailureMesgFailure message for Fanro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.22.400 |
tempFailureMesgFailure message for system temperaturero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.22.401 |
powerVoltageMesgFailure message for system powerro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.22.402 |
raidEventNoticeMesgRAID hotplug event messagero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.22.403 |
snapshotEventNoticeMesgSnapshot messagesro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.22.404 |
upsEventNoticeMesgUPS status messagero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.22.405 |
hotplugDiskNoticeMesgDisk hotplug event messagesro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.22.406 |
volumeNoticeMesgDisk usage warningro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.22.407 |
diskTempWarningMesgDisk temperature warning messagesro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.22.408 |
backupNoticeMesgBackup job status messagesro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.22.409 |
diskSmartWarningMesgDisk SMART messagesro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.22.410 |
psuWarningMesgPSU status messagesro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4526.22.411 |
productID OBJECT IDENTIFIER .1.3.6.1.4.1.4526.100 |
readyDATAOS OBJECT IDENTIFIER .1.3.6.1.4.1.4526.100.15 |