Home/Catalog/READYDATAOS-MIB

READYDATAOS-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for READYDATAOS-MIB.

83
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

83 total
Object Name
netgear
OBJECT IDENTIFIER
.1.3.6.1.4.1.4526
IMPORTS
Unknown
.1.3.6.1.4.1.4526
ngNasManager
OBJECT IDENTIFIER
.1.3.6.1.4.1.4526.22
nasMgrSoftwareVersionVersion information for the ReadyDATAOS ngNasManager software.ro
DisplayString
.1.3.6.1.4.1.4526.22.1
diskTableA table of physical disks attached to the storage device.
SEQUENCE OF DiskEntry
.1.3.6.1.4.1.4526.22.3
diskEntryAn entry in the physical disk table.
DiskEntry
.1.3.6.1.4.1.4526.22.3.1
diskNumberInstance number of the disk entry.ro
INTEGER
.1.3.6.1.4.1.4526.22.3.1.1
diskIDDisk ID.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4526.22.3.1.2
diskSlotNameThe slot location of the disk.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4526.22.3.1.3
diskSerialDisk Serial number.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4526.22.3.1.4
diskModelThe disk drive's model name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4526.22.3.1.5
ataErrorATA error number for this disk from S.M.A.R.T read.ro
INTEGER
.1.3.6.1.4.1.4526.22.3.1.6
diskCapacityThe capacity of the disk in bytes.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4526.22.3.1.7
diskInterfaceThe disk connect interface, such as SATA, USB etc.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4526.22.3.1.8
diskStateThe current state of the Disk. Possible states: 0: Online 1: Offlinero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4526.22.3.1.9
diskTemperaturetemperature of this disk(in Fahrenheit unit).ro
INTEGER
.1.3.6.1.4.1.4526.22.3.1.10
fanTable
SEQUENCE OF FanEntry
.1.3.6.1.4.1.4526.22.4
fanEntry
FanEntry
.1.3.6.1.4.1.4526.22.4.1
fanNumberInstance number of this fan entry.ro
INTEGER
.1.3.6.1.4.1.4526.22.4.1.1
fanRPMThe current speed of the fan.ro
INTEGER
.1.3.6.1.4.1.4526.22.4.1.2
fanStatusThe status of Fanro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4526.22.4.1.3
fanTypeWhat fan is used for: SYS: for system board CPU: for CPU CASE: for system casero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4526.22.4.1.4
temperatureTable
SEQUENCE OF TemperatureEntry
.1.3.6.1.4.1.4526.22.5
temperatureEntry
TemperatureEntry
.1.3.6.1.4.1.4526.22.5.1
temperatureNumberInstance number of this temperature probe entry.ro
INTEGER
.1.3.6.1.4.1.4526.22.5.1.1
temperatureValueThe current temperature of this probe (in Fahrenheit unit).ro
INTEGER
.1.3.6.1.4.1.4526.22.5.1.2
temperatureTyoeThe current temperature refer toro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4526.22.5.1.3
temperatureMinThe min temperature of this probe (in Fahrenheit unit).ro
INTEGER
.1.3.6.1.4.1.4526.22.5.1.4
temperatureMaxThe max temperature of this probe (in Fahrenheit unit).ro
INTEGER
.1.3.6.1.4.1.4526.22.5.1.5
volumeTableA table of active volumes on the storage device.
SEQUENCE OF VolumeEntry
.1.3.6.1.4.1.4526.22.7
volumeEntryAn entry in the volume table.
VolumeEntry
.1.3.6.1.4.1.4526.22.7.1
volumeNumberInstance number of the volume entry.ro
INTEGER
.1.3.6.1.4.1.4526.22.7.1.1
volumeNameThe name of the volume.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4526.22.7.1.2
volumeRAIDLevelThe RAID level of the volume.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4526.22.7.1.3
volumeStatusThe severity of the volume. Possible values: 1: ONLINE 2: OFFLINE 3: DEGRADED 4: FAULTED 5: REMOVED 6: UNAVAILABLE 7: UNKNOWNro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4526.22.7.1.4
volumeSizeThe size of the volume in megabytes.ro
INTEGER
.1.3.6.1.4.1.4526.22.7.1.5
volumeFreeSpaceFree space on the volume in megabytes.ro
INTEGER
.1.3.6.1.4.1.4526.22.7.1.6
psuTable
SEQUENCE OF PSUEntry
.1.3.6.1.4.1.4526.22.8
psuEntryro
PSUEntry
.1.3.6.1.4.1.4526.22.8.1
psuNumberInstance number of this power supply unit.ro
INTEGER
.1.3.6.1.4.1.4526.22.8.1.1
psuDescThe description of this PSU.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4526.22.8.1.2
psuStatusThe current PSU status.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4526.22.8.1.3
aryMgrEvts
OBJECT IDENTIFIER
.1.3.6.1.4.1.4526.22.200
controllerNameEvController Name for which trap is generated.ro
DisplayString
.1.3.6.1.4.1.4526.22.200.201
channelNumberEvChannel Number for which trap is generated.ro
INTEGER
.1.3.6.1.4.1.4526.22.200.202
targetIDEvSCSI ID of the device for which trap is generated.ro
INTEGER
.1.3.6.1.4.1.4526.22.200.203
virtualDiskNameEvVirtual Disk for which trap is generated.ro
DisplayString
.1.3.6.1.4.1.4526.22.200.204
arrayDiskNameEvArray Disk for which trap is generated.ro
DisplayString
.1.3.6.1.4.1.4526.22.200.205
oldVDConfigEvCurrent Virtual Disk configuration for which trap is generatedro
DisplayString
.1.3.6.1.4.1.4526.22.200.206
newVDConfigEvNew Virtual Disk configuration for which trap is generated.ro
DisplayString
.1.3.6.1.4.1.4526.22.200.207
enclosureNumberEvEnclosure Number for which trap is generated.ro
INTEGER
.1.3.6.1.4.1.4526.22.200.208
unitNumberEvUnit Number for which trap is generated. (Fan, Power Supply, Temperature Probe)ro
INTEGER
.1.3.6.1.4.1.4526.22.200.209
enclosureNameEvEnclosure Name for which trap is generated.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4526.22.200.210
unitNameEvUnit Number for which trap is generated. (Fan, Power Supply, Temperature Probe)ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4526.22.200.211
timeEvAmount of time specified in the trap message.ro
INTEGER
.1.3.6.1.4.1.4526.22.200.212
volumeNameEvVolume Drive Letter for which trap is generated.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4526.22.200.213
nasTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.4526.22.300
fanFailureFan failure, fan speed is %s.
TRAP-TYPE
.1.3.6.1.4.1.4526.22.300.0.10
tempFailureTemperature sensor reports out of normal range.
TRAP-TYPE
.1.3.6.1.4.1.4526.22.300.0.20
powerVoltageSystem power is out of spec, please check system status!
TRAP-TYPE
.1.3.6.1.4.1.4526.22.300.0.30
raidEventNoticeRAID event detected!
TRAP-TYPE
.1.3.6.1.4.1.4526.22.300.0.40
snapshotEventNoticeSnapshot event detected!
TRAP-TYPE
.1.3.6.1.4.1.4526.22.300.0.50
hotplugDiskNoticeHotplug disk event detected!
TRAP-TYPE
.1.3.6.1.4.1.4526.22.300.0.60
upsEventNoticeUPS status.
TRAP-TYPE
.1.3.6.1.4.1.4526.22.300.0.70
volumeNoticeVolume is approaching capacity.
TRAP-TYPE
.1.3.6.1.4.1.4526.22.300.0.80
diskTempWarningDisk temperature warning.
TRAP-TYPE
.1.3.6.1.4.1.4526.22.300.0.90
backupNoticeBackup job status.
TRAP-TYPE
.1.3.6.1.4.1.4526.22.300.0.100
diskSmartWarningDisk SMART warning.
TRAP-TYPE
.1.3.6.1.4.1.4526.22.300.0.110
psuWarningPower supply unit warning.
TRAP-TYPE
.1.3.6.1.4.1.4526.22.300.0.120
fanFailureMesgFailure message for Fanro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4526.22.400
tempFailureMesgFailure message for system temperaturero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4526.22.401
powerVoltageMesgFailure message for system powerro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4526.22.402
raidEventNoticeMesgRAID hotplug event messagero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4526.22.403
snapshotEventNoticeMesgSnapshot messagesro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4526.22.404
upsEventNoticeMesgUPS status messagero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4526.22.405
hotplugDiskNoticeMesgDisk hotplug event messagesro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4526.22.406
volumeNoticeMesgDisk usage warningro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4526.22.407
diskTempWarningMesgDisk temperature warning messagesro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4526.22.408
backupNoticeMesgBackup job status messagesro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4526.22.409
diskSmartWarningMesgDisk SMART messagesro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4526.22.410
psuWarningMesgPSU status messagesro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4526.22.411
productID
OBJECT IDENTIFIER
.1.3.6.1.4.1.4526.100
readyDATAOS
OBJECT IDENTIFIER
.1.3.6.1.4.1.4526.100.15

More MIBs from Netgear

Browse all NetgearMIBs →
WING-MIB

Standard SNMP MIB module defining data structures for WING-MIB.

3564 objects→
FASTPATH-SWITCHING-MIB

The FASTPATH-SWITCHING-MIB enables monitoring and management of Netgear FastPath switching hardware, specifically exposing metrics related to Layer 2 forwarding tables, MAC address aging, VLAN configurations, and port statistics. This private MIB facilitates the tracking of switching plane performance and state changes within Netgear's proprietary FastPath operating environment.

731 objects→
NETGEAR-SMART-SWITCHING-MIB

The NETGEAR-SMART-SWITCHING-MIB provides vendor-specific OID extensions for monitoring and managing Layer 2 switching functions, including port status, MAC address tables, VLAN configurations, and spanning tree states on Netgear Smart Switches. This private MIB enables network management systems to retrieve granular operational data and control parameters specific to Netgear's proprietary switching firmware that are not covered by standard IEEE MIBs.

476 objects→
NETGEAR-SWITCHING-MIB

The NETGEAR-SWITCHING-MIB provides vendor-specific extensions for monitoring and managing Layer 2 switching functions on Netgear network switches, including port status, MAC address table entries, and VLAN configurations. It enables SNMP-based retrieval of proprietary switching metrics not covered by standard IETF MIBs to facilitate granular fault isolation and traffic analysis within Netgear-managed infrastructure.

476 objects→
GSM7324-SWITCHING-MIB

SNMP MIB module

327 objects→
GSM7312-SWITCHING-MIB

Standard SNMP MIB module defining data structures for GSM7312-SWITCHING-MIB.

327 objects→