Home/Catalog/RC7586-MIB

RC7586-MIB

The Structure of Management Information for the Codan enterprise. Copyright(c) 2009 All rights reserved
Main OID:
rc7586MIB.1.3.6.1.4.1.23304.2.2
111
Objects
Active
Status
3
Dependencies

Imported Objects

Objects

111 total
Object Name
rc7586MIBThe Structure of Management Information for the Codan enterprise. Copyright(c) 2009 All rights reserved
MODULE-IDENTITY
.1.3.6.1.4.1.23304.2.2
buc1
OBJECT IDENTIFIER
.1.3.6.1.4.1.23304.2.2.1
buc1Configuration
OBJECT IDENTIFIER
.1.3.6.1.4.1.23304.2.2.1.1
buc1TxSettings
OBJECT IDENTIFIER
.1.3.6.1.4.1.23304.2.2.1.1.1
buc1TxOnSets Tx on/off. Respond -1 if buc1 not connected.rw
INTEGER
.1.3.6.1.4.1.23304.2.2.1.1.1.1
buc1TxDefaultSets Tx default 1-last 0-off. Respond -1 if buc1 not connected.rw
INTEGER
.1.3.6.1.4.1.23304.2.2.1.1.1.2
buc1TxAttenuatorSets/Gets Tx attenuation value in 1dBm steps. Respond -1 if buc1 not connected.rw
INTEGER
.1.3.6.1.4.1.23304.2.2.1.1.1.3
buc1PktProtocol
OBJECT IDENTIFIER
.1.3.6.1.4.1.23304.2.2.1.1.2
buc1ProtocolSets/Gets packet protocol 0 - ASCII, 1 - CODAN, 2 - SAbus, 3 - Comstream, 4 - NDSatcom. Respond -1 if buc1 not connected.rw
INTEGER
.1.3.6.1.4.1.23304.2.2.1.1.2.1
buc1AddressSets/Gets packet address: 0-31 NDSatcom ...Respond -1 if buc1 not connected.rw
INTEGER
.1.3.6.1.4.1.23304.2.2.1.1.2.2
buc1RCSetting
OBJECT IDENTIFIER
.1.3.6.1.4.1.23304.2.2.1.1.3
buc1ModeSets/Gets redundancy mode 0-none, 1-warm, 2-hot. Respond -1 if buc1 not connected.rw
INTEGER
.1.3.6.1.4.1.23304.2.2.1.1.3.1
buc1OnLineSets/Gets redundancy mode on on/off line state. Respond -1 if buc1 not connected.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.23304.2.2.1.1.3.2
buc1Freqs
OBJECT IDENTIFIER
.1.3.6.1.4.1.23304.2.2.1.1.4
buc1RFFreqSets/Gets the RBUC RF frequency. Respond -1 if buc1 not connected.rw
INTEGER UNITS "MHz"
.1.3.6.1.4.1.23304.2.2.1.1.4.1
buc1IFFreqSets/Gets the RBUC IF frequency. Respond -1 if buc1 not connected.rw
INTEGER UNITS "MHz"
.1.3.6.1.4.1.23304.2.2.1.1.4.2
buc1LOFreqSets/Gets the RBUC LO frequency. Respond -1 if buc1 not connected.rw
INTEGER UNITS "MHz"
.1.3.6.1.4.1.23304.2.2.1.1.4.3
buc1Misc
OBJECT IDENTIFIER
.1.3.6.1.4.1.23304.2.2.1.1.5
buc1SerIfSets/Gets serial interface - rate, length, parity, stop, terminate RS422/485. **** No respond - message if buc1 not connected.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23304.2.2.1.1.5.1
buc1PwrAlarmThreshSets/Gets power alarm threshold. **** No respond - message if buc1 not connected.rw
DisplayString UNITS "dB"
.1.3.6.1.4.1.23304.2.2.1.1.5.2
buc1BurstPwrThreshSets/Gets burst power threshold. **** No respond - message if buc1 not connected.rw
DisplayString UNITS "dB"
.1.3.6.1.4.1.23304.2.2.1.1.5.3
buc1RefSourceSets/Gets reference source 0-external, 1-internal (Only for RBUC). **** No respond - message if buc1 not connected.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23304.2.2.1.1.5.4
buc1LEDStateSets/Gets LEDs status on/off (Only for RBUC). **** No respond - message if buc1 not connected.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23304.2.2.1.1.5.5
buc1Status
OBJECT IDENTIFIER
.1.3.6.1.4.1.23304.2.2.1.2
buc1PaStatusGets to 1 when PA is on. Respond -1 if buc1 not connected.ro
INTEGER
.1.3.6.1.4.1.23304.2.2.1.2.1
buc1TxPowerGets Tx power format x.x dB. **** No respond - message if buc1 not connected.ro
DisplayString UNITS "dB"
.1.3.6.1.4.1.23304.2.2.1.2.2
buc1TxBurstPowerGets Tx power. Format is x.x,y.y,z.z, where x.x is current burst power, y.y is min and z.z is max burts power. **** No respond - message if buc1 not connected.ro
DisplayString UNITS "dB"
.1.3.6.1.4.1.23304.2.2.1.2.3
buc1FaultsGets the current fault status. Format - Bit0 PA fault, Bit1 Fan fault, Bit2 Power fault, Bit3 Temp fault, Bit4 10MHz fault, Bit5 Internal fault Bit6 LNB fault, Bit7 Red'cy Cont fault. Respond -1 if buc2 not connected.ro
INTEGER
.1.3.6.1.4.1.23304.2.2.1.2.4
buc1LatchedFaultsGets the current latched faults. Format is same as Faults. Respond -1 if buc2 not connected.ro
INTEGER
.1.3.6.1.4.1.23304.2.2.1.2.5
buc1TemperatureGets the BUC temperature. Format is x.x. **** No respond - message if buc1 not connected.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23304.2.2.1.2.6
buc1MinMaxTemperatureGets the BUC temperature. Format is x.x,y.y where x.x is max and y.y is min temperature. **** No respond - message if buc1 not connected.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23304.2.2.1.2.7
buc1SystemSettingGets the current system status. Format is Bit0 - PA state, Bit1 - RS232 Tx, Bit2 - FSK Tx, Bit3 - RS485 Tx Bit4 - Redundancy mode, Bit5 - Online, Bit6..Bit7 - Redundancy cold or hot mode, Bit8 - HTTP Tx, Bit9 - TELNET Tx, Bit10 - SNMP Tx. Respond -1 if buc1 not connected.ro
INTEGER
.1.3.6.1.4.1.23304.2.2.1.2.8
buc1SystemPollGets the system poll status. Format is Bit0 - Fault, Bit1 - System change. Respond -1 if buc1 not connected.ro
INTEGER
.1.3.6.1.4.1.23304.2.2.1.2.9
buc1DeviceTypeGets the device type. Format is X,Y where X is the model and Y is software version. **** No respond - message if buc1 not connected.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23304.2.2.1.2.10
buc1GatewayGets the BUC gateway address (Only for RBUC). **** No respond - message if buc1 not connected.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23304.2.2.1.2.11
buc1IpAddressGets the BUC IP address (Only for RBUC). **** No respond - message if buc1 not connected.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23304.2.2.1.2.12
buc1MACAddressGets the BUC MAC address (Only for RBUC). **** No respond - message if buc1 not connected.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23304.2.2.1.2.13
buc1NetmaskGets the BUC netmask (Only for RBUC). **** No respond - message if buc1 not connected.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23304.2.2.1.2.14
buc1RefPowerGets the BUC reference power. **** No respond - message if buc1 not connected.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23304.2.2.1.2.15
buc1ConfigGets the BUC configuration. **** No respond - message if buc1 not connected.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23304.2.2.1.2.16
buc1BuildStandardGets the BUC build standard. **** No respond - message if buc1 not connected.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23304.2.2.1.2.17
buc1Info
OBJECT IDENTIFIER
.1.3.6.1.4.1.23304.2.2.1.3
buc1IdInfoGets the module firmware revision, serial number and model. This string will have a zero length if the revision is unknown. **** No respond - message if buc1 not connected.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23304.2.2.1.3.1
buc1LimitsGets the limit data for the BUC. Format is: Power meter MIN/MAX , IF,RF and LO frequencies. This string will have a zero length if the revision is unknown. **** No respond - message if buc1 not connected.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23304.2.2.1.3.2
buc1PktProtocolsInfoGets supported packet protocols and the corresponding address ranges. **** No respond - message if buc1 not connected.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23304.2.2.1.3.3
buc2
OBJECT IDENTIFIER
.1.3.6.1.4.1.23304.2.2.2
buc2Configuration
OBJECT IDENTIFIER
.1.3.6.1.4.1.23304.2.2.2.1
buc2TxSettings
OBJECT IDENTIFIER
.1.3.6.1.4.1.23304.2.2.2.1.1
buc2TxOnSets Tx on/off. Respond -1 if buc2 not connected.rw
INTEGER
.1.3.6.1.4.1.23304.2.2.2.1.1.1
buc2TxDefaultSets Tx default 1-last 0-off. Respond -1 if buc2 not connected.rw
INTEGER
.1.3.6.1.4.1.23304.2.2.2.1.1.2
buc2TxAttenuatorSets/Gets Tx attenuation value in 1dBm steps. Respond -1 if buc2 not connected.rw
INTEGER
.1.3.6.1.4.1.23304.2.2.2.1.1.3
buc2PktProtocol
OBJECT IDENTIFIER
.1.3.6.1.4.1.23304.2.2.2.1.2
buc2ProtocolSets/Gets packet protocol 0 - ASCII, 1 - CODAN, 2 - SAbus, 3 - Comstream, 4 - NDSatcom. Respond -1 if buc2 not connected.rw
INTEGER
.1.3.6.1.4.1.23304.2.2.2.1.2.1
buc2AddressSets/Gets packet address: 0-31 NDSatcom ...Respond -1 if buc2 not connected.rw
INTEGER
.1.3.6.1.4.1.23304.2.2.2.1.2.2
buc2RCSetting
OBJECT IDENTIFIER
.1.3.6.1.4.1.23304.2.2.2.1.3
buc2ModeSets/Gets redundancy mode 0-none, 1-warm, 2-hot. Respond -1 if buc2 not connected.rw
INTEGER
.1.3.6.1.4.1.23304.2.2.2.1.3.1
buc2OnLineSets/Gets redundancy mode on on/off line state. Respond -1 if buc2 not connected.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.23304.2.2.2.1.3.2
buc2Freqs
OBJECT IDENTIFIER
.1.3.6.1.4.1.23304.2.2.2.1.4
buc2RFFreqSets/Gets the RBUC RF frequency. Respond -1 if buc2 not connected.rw
INTEGER UNITS "MHz"
.1.3.6.1.4.1.23304.2.2.2.1.4.1
buc2IFFreqSets/Gets the RBUC IF frequency. Respond -1 if buc2 not connected.rw
INTEGER UNITS "MHz"
.1.3.6.1.4.1.23304.2.2.2.1.4.2
buc2LOFreqSets/Gets the RBUC LO frequency. Respond -1 if buc2 not connected.rw
INTEGER UNITS "MHz"
.1.3.6.1.4.1.23304.2.2.2.1.4.3
buc2Misc
OBJECT IDENTIFIER
.1.3.6.1.4.1.23304.2.2.2.1.5
buc2SerIfSets/Gets serial interface - rate, length, parity, stop, terminate RS422/485. **** No respond - message if buc2 not connected.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23304.2.2.2.1.5.1
buc2PwrAlarmThreshSets/Gets power alarm threshold. **** No respond - message if buc2 not connected.rw
DisplayString UNITS "dB"
.1.3.6.1.4.1.23304.2.2.2.1.5.2
buc2BurstPwrThreshSets/Gets burst power threshold. **** No respond - message if buc2 not connected.rw
DisplayString UNITS "dB"
.1.3.6.1.4.1.23304.2.2.2.1.5.3
buc2RefSourceSets/Gets reference source 0-external, 1-internal (Only for RBUC). **** No respond - message if buc2 not connected.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23304.2.2.2.1.5.4
buc2LEDStateSets/Gets LEDs status on/off (Only for RBUC). **** No respond - message if buc2 not connected.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23304.2.2.2.1.5.5
buc2Status
OBJECT IDENTIFIER
.1.3.6.1.4.1.23304.2.2.2.2
buc2PaStatusGets to 1 when PA is on. Respond -1 if buc2 not connected.ro
INTEGER
.1.3.6.1.4.1.23304.2.2.2.2.1
buc2TxPowerGets Tx power format x.x dB. **** No respond - message if buc2 not connected.ro
DisplayString UNITS "dB"
.1.3.6.1.4.1.23304.2.2.2.2.2
buc2TxBurstPowerGets Tx power. Format is x.x,y.y,z.z, where x.x is current burst power, y.y is min and z.z is max burts power. **** No respond - message if buc2 not connected.ro
DisplayString UNITS "dB"
.1.3.6.1.4.1.23304.2.2.2.2.3
buc2FaultsGets the current fault status. Format - Bit0 PA fault, Bit1 Fan fault, Bit2 Power fault, Bit3 Temp fault, Bit4 10MHz fault, Bit5 Internal fault Bit6 LNB fault, Bit7 Red'cy Cont fault. Respond -1 if buc2 not connected.ro
INTEGER
.1.3.6.1.4.1.23304.2.2.2.2.4
buc2LatchedFaultsGets the current latched faults. Format is same as Faults. Respond -1 if buc2 not connected.ro
INTEGER
.1.3.6.1.4.1.23304.2.2.2.2.5
buc2TemperatureGets the BUC temperature. Format is x.x. **** No respond - message if buc2 not connected.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23304.2.2.2.2.6
buc2MinMaxTemperatureGets the BUC temperature. Format is x.x,y.y where x.x is max and y.y is min temperature. **** No respond - message if buc2 not connected.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23304.2.2.2.2.7
buc2SystemSettingGets the current system status. Format is Bit0 - PA state, Bit1 - RS232 Tx, Bit2 - FSK Tx, Bit3 - RS485 Tx Bit4 - Redundancy mode, Bit5 - Online, Bit6..Bit7 - Redundancy cold or hot mode, Bit8 - HTTP Tx, Bit9 - TELNET Tx, Bit10 - SNMP Tx. Respond -1 if buc2 not connected.ro
INTEGER
.1.3.6.1.4.1.23304.2.2.2.2.8
buc2SystemPollGets the system poll status. Format is Bit0 - Fault, Bit1 - System change. Respond -1 if buc2 not connected.ro
INTEGER
.1.3.6.1.4.1.23304.2.2.2.2.9
buc2DeviceTypeGets the device type. Format is X,Y where X is the model and Y is software version. **** No respond - message if buc2 not connected.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23304.2.2.2.2.10
buc2GatewayGets the BUC gateway address (Only for RBUC). **** No respond - message if buc2 not connected.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23304.2.2.2.2.11
buc2IpAddressGets the BUC IP address (Only for RBUC). **** No respond - message if buc2 not connected.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23304.2.2.2.2.12
buc2MACAddressGets the BUC MAC address (Only for RBUC). **** No respond - message if buc2 not connected.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23304.2.2.2.2.13
buc2NetmaskGets the BUC netmask (Only for RBUC). **** No respond - message if buc2 not connected.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23304.2.2.2.2.14
buc2RefPowerGets the BUC reference power. **** No respond - message if buc2 not connected.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23304.2.2.2.2.15
buc2ConfigGets the BUC configuration. **** No respond - message if buc2 not connected.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23304.2.2.2.2.16
buc2BuildStandardGets the BUC build standard. **** No respond - message if buc2 not connected.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23304.2.2.2.2.17
buc2Info
OBJECT IDENTIFIER
.1.3.6.1.4.1.23304.2.2.2.3
buc2IdInfoGets the module firmware revision, serial number and model. This string will have a zero length if the revision is unknown. **** No respond - message if buc2 not connected.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23304.2.2.2.3.1
buc2LimitsGets the limit data for the BUC. Format is: Power meter MIN/MAX , IF,RF and LO frequencies. This string will have a zero length if the revision is unknown. **** No respond - message if buc2 not connected.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23304.2.2.2.3.2
buc2PktProtocolsInfoGets supported packet protocols and the corresponding address ranges. **** No respond - message if buc2 not connected.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23304.2.2.2.3.3
ctrl
OBJECT IDENTIFIER
.1.3.6.1.4.1.23304.2.2.3
settings
OBJECT IDENTIFIER
.1.3.6.1.4.1.23304.2.2.3.1
operationalModeSets 7586 operational mode - Auto, Manual Stream1, Stream2.rw
INTEGER
.1.3.6.1.4.1.23304.2.2.3.1.1
onlineStreamSets the online stream.rw
INTEGER
.1.3.6.1.4.1.23304.2.2.3.1.2
waveguideSwitchSets Waveguide switch Rx+Tx, Rx/Tx and Tx Only.rw
INTEGER
.1.3.6.1.4.1.23304.2.2.3.1.3
startupTimeSets Startup time.rw
INTEGER
.1.3.6.1.4.1.23304.2.2.3.1.4
lnbCurrentLimitSets LNB current limits.rw
DisplayString UNITS "mA"
.1.3.6.1.4.1.23304.2.2.3.1.5
ledStateSets 7586 LED.rw
INTEGER
.1.3.6.1.4.1.23304.2.2.3.1.6
refSourceSets 7586 reference state.rw
INTEGER
.1.3.6.1.4.1.23304.2.2.3.1.7
refTrimSets 7586 reference trim.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23304.2.2.3.1.8
refThreshSets 7586 reference alarm treshold.rw
DisplayString UNITS "dBm"
.1.3.6.1.4.1.23304.2.2.3.1.9
refPwrGets 7586 reference power.ro
DisplayString UNITS "dBm"
.1.3.6.1.4.1.23304.2.2.3.1.10
ipAddrGets the 7586 IP address.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23304.2.2.3.1.11
macAddressGets the 7586 MAC address.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23304.2.2.3.1.12
netmaskGets the 7586 netmask.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23304.2.2.3.1.13
gatewayGets the 7586 gateway address.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23304.2.2.3.1.14
status
OBJECT IDENTIFIER
.1.3.6.1.4.1.23304.2.2.3.2
lnbCurrentSets 7586 LNB current.ro
DisplayString UNITS "mA"
.1.3.6.1.4.1.23304.2.2.3.2.1
lnbVoltageSets 7586 LNB voltage.ro
DisplayString UNITS "V"
.1.3.6.1.4.1.23304.2.2.3.2.2
faultsGets the current fault status.ro
INTEGER
.1.3.6.1.4.1.23304.2.2.3.2.3
info
OBJECT IDENTIFIER
.1.3.6.1.4.1.23304.2.2.3.3
idInfoGets the module firmware revision, serial number and model. This string will have a zero length if the revision is unknown.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.23304.2.2.3.3.1
RC7586-MIB - SNMP MIB Reference | MIBs Explorer