RC7586-MIB
The Structure of Management Information for the Codan enterprise. Copyright(c) 2009 All rights reserved
Main OID:
rc7586MIB.1.3.6.1.4.1.23304.2.2
111
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
111 total| Object Name |
|---|
rc7586MIBThe Structure of Management Information for the Codan enterprise. Copyright(c) 2009 All rights reserved MODULE-IDENTITY .1.3.6.1.4.1.23304.2.2 |
buc1 OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.1 |
buc1Configuration OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.1.1 |
buc1TxSettings OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.1.1.1 |
buc1TxOnSets Tx on/off. Respond -1 if buc1 not connected.rw INTEGER .1.3.6.1.4.1.23304.2.2.1.1.1.1 |
buc1TxDefaultSets Tx default 1-last 0-off. Respond -1 if buc1 not connected.rw INTEGER .1.3.6.1.4.1.23304.2.2.1.1.1.2 |
buc1TxAttenuatorSets/Gets Tx attenuation value in 1dBm steps. Respond -1 if buc1 not connected.rw INTEGER .1.3.6.1.4.1.23304.2.2.1.1.1.3 |
buc1PktProtocol OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.1.1.2 |
buc1ProtocolSets/Gets packet protocol 0 - ASCII, 1 - CODAN, 2 - SAbus, 3 - Comstream, 4 - NDSatcom. Respond -1 if buc1 not connected.rw INTEGER .1.3.6.1.4.1.23304.2.2.1.1.2.1 |
buc1AddressSets/Gets packet address: 0-31 NDSatcom ...Respond -1 if buc1 not connected.rw INTEGER .1.3.6.1.4.1.23304.2.2.1.1.2.2 |
buc1RCSetting OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.1.1.3 |
buc1ModeSets/Gets redundancy mode 0-none, 1-warm, 2-hot. Respond -1 if buc1 not connected.rw INTEGER .1.3.6.1.4.1.23304.2.2.1.1.3.1 |
buc1OnLineSets/Gets redundancy mode on on/off line state. Respond -1 if buc1 not connected.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.1.1.3.2 |
buc1Freqs OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.1.1.4 |
buc1RFFreqSets/Gets the RBUC RF frequency. Respond -1 if buc1 not connected.rw INTEGER UNITS "MHz" .1.3.6.1.4.1.23304.2.2.1.1.4.1 |
buc1IFFreqSets/Gets the RBUC IF frequency. Respond -1 if buc1 not connected.rw INTEGER UNITS "MHz" .1.3.6.1.4.1.23304.2.2.1.1.4.2 |
buc1LOFreqSets/Gets the RBUC LO frequency. Respond -1 if buc1 not connected.rw INTEGER UNITS "MHz" .1.3.6.1.4.1.23304.2.2.1.1.4.3 |
buc1Misc OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.1.1.5 |
buc1SerIfSets/Gets serial interface - rate, length, parity, stop, terminate RS422/485. **** No respond - message if buc1 not connected.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.1.1.5.1 |
buc1PwrAlarmThreshSets/Gets power alarm threshold. **** No respond - message if buc1 not connected.rw DisplayString UNITS "dB" .1.3.6.1.4.1.23304.2.2.1.1.5.2 |
buc1BurstPwrThreshSets/Gets burst power threshold. **** No respond - message if buc1 not connected.rw DisplayString UNITS "dB" .1.3.6.1.4.1.23304.2.2.1.1.5.3 |
buc1RefSourceSets/Gets reference source 0-external, 1-internal (Only for RBUC). **** No respond - message if buc1 not connected.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.1.1.5.4 |
buc1LEDStateSets/Gets LEDs status on/off (Only for RBUC). **** No respond - message if buc1 not connected.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.1.1.5.5 |
buc1Status OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.1.2 |
buc1PaStatusGets to 1 when PA is on. Respond -1 if buc1 not connected.ro INTEGER .1.3.6.1.4.1.23304.2.2.1.2.1 |
buc1TxPowerGets Tx power format x.x dB. **** No respond - message if buc1 not connected.ro DisplayString UNITS "dB" .1.3.6.1.4.1.23304.2.2.1.2.2 |
buc1TxBurstPowerGets Tx power. Format is x.x,y.y,z.z, where x.x is current burst power, y.y is min and z.z is max burts power. **** No respond - message if buc1 not connected.ro DisplayString UNITS "dB" .1.3.6.1.4.1.23304.2.2.1.2.3 |
buc1FaultsGets the current fault status. Format - Bit0 PA fault, Bit1 Fan fault, Bit2 Power fault, Bit3 Temp fault, Bit4 10MHz fault, Bit5 Internal fault Bit6 LNB fault, Bit7 Red'cy Cont fault. Respond -1 if buc2 not connected.ro INTEGER .1.3.6.1.4.1.23304.2.2.1.2.4 |
buc1LatchedFaultsGets the current latched faults. Format is same as Faults. Respond -1 if buc2 not connected.ro INTEGER .1.3.6.1.4.1.23304.2.2.1.2.5 |
buc1TemperatureGets the BUC temperature. Format is x.x. **** No respond - message if buc1 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.1.2.6 |
buc1MinMaxTemperatureGets the BUC temperature. Format is x.x,y.y where x.x is max and y.y is min temperature. **** No respond - message if buc1 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.1.2.7 |
buc1SystemSettingGets the current system status. Format is Bit0 - PA state, Bit1 - RS232 Tx, Bit2 - FSK Tx, Bit3 - RS485 Tx Bit4 - Redundancy mode, Bit5 - Online, Bit6..Bit7 - Redundancy cold or hot mode, Bit8 - HTTP Tx, Bit9 - TELNET Tx, Bit10 - SNMP Tx. Respond -1 if buc1 not connected.ro INTEGER .1.3.6.1.4.1.23304.2.2.1.2.8 |
buc1SystemPollGets the system poll status. Format is Bit0 - Fault, Bit1 - System change. Respond -1 if buc1 not connected.ro INTEGER .1.3.6.1.4.1.23304.2.2.1.2.9 |
buc1DeviceTypeGets the device type. Format is X,Y where X is the model and Y is software version. **** No respond - message if buc1 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.1.2.10 |
buc1GatewayGets the BUC gateway address (Only for RBUC). **** No respond - message if buc1 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.1.2.11 |
buc1IpAddressGets the BUC IP address (Only for RBUC). **** No respond - message if buc1 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.1.2.12 |
buc1MACAddressGets the BUC MAC address (Only for RBUC). **** No respond - message if buc1 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.1.2.13 |
buc1NetmaskGets the BUC netmask (Only for RBUC). **** No respond - message if buc1 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.1.2.14 |
buc1RefPowerGets the BUC reference power. **** No respond - message if buc1 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.1.2.15 |
buc1ConfigGets the BUC configuration. **** No respond - message if buc1 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.1.2.16 |
buc1BuildStandardGets the BUC build standard. **** No respond - message if buc1 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.1.2.17 |
buc1Info OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.1.3 |
buc1IdInfoGets the module firmware revision, serial number and model. This string will have a zero length if the revision is unknown. **** No respond - message if buc1 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.1.3.1 |
buc1LimitsGets the limit data for the BUC. Format is: Power meter MIN/MAX , IF,RF and LO frequencies. This string will have a zero length if the revision is unknown. **** No respond - message if buc1 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.1.3.2 |
buc1PktProtocolsInfoGets supported packet protocols and the corresponding address ranges. **** No respond - message if buc1 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.1.3.3 |
buc2 OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.2 |
buc2Configuration OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.2.1 |
buc2TxSettings OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.2.1.1 |
buc2TxOnSets Tx on/off. Respond -1 if buc2 not connected.rw INTEGER .1.3.6.1.4.1.23304.2.2.2.1.1.1 |
buc2TxDefaultSets Tx default 1-last 0-off. Respond -1 if buc2 not connected.rw INTEGER .1.3.6.1.4.1.23304.2.2.2.1.1.2 |
buc2TxAttenuatorSets/Gets Tx attenuation value in 1dBm steps. Respond -1 if buc2 not connected.rw INTEGER .1.3.6.1.4.1.23304.2.2.2.1.1.3 |
buc2PktProtocol OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.2.1.2 |
buc2ProtocolSets/Gets packet protocol 0 - ASCII, 1 - CODAN, 2 - SAbus, 3 - Comstream, 4 - NDSatcom. Respond -1 if buc2 not connected.rw INTEGER .1.3.6.1.4.1.23304.2.2.2.1.2.1 |
buc2AddressSets/Gets packet address: 0-31 NDSatcom ...Respond -1 if buc2 not connected.rw INTEGER .1.3.6.1.4.1.23304.2.2.2.1.2.2 |
buc2RCSetting OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.2.1.3 |
buc2ModeSets/Gets redundancy mode 0-none, 1-warm, 2-hot. Respond -1 if buc2 not connected.rw INTEGER .1.3.6.1.4.1.23304.2.2.2.1.3.1 |
buc2OnLineSets/Gets redundancy mode on on/off line state. Respond -1 if buc2 not connected.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.2.1.3.2 |
buc2Freqs OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.2.1.4 |
buc2RFFreqSets/Gets the RBUC RF frequency. Respond -1 if buc2 not connected.rw INTEGER UNITS "MHz" .1.3.6.1.4.1.23304.2.2.2.1.4.1 |
buc2IFFreqSets/Gets the RBUC IF frequency. Respond -1 if buc2 not connected.rw INTEGER UNITS "MHz" .1.3.6.1.4.1.23304.2.2.2.1.4.2 |
buc2LOFreqSets/Gets the RBUC LO frequency. Respond -1 if buc2 not connected.rw INTEGER UNITS "MHz" .1.3.6.1.4.1.23304.2.2.2.1.4.3 |
buc2Misc OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.2.1.5 |
buc2SerIfSets/Gets serial interface - rate, length, parity, stop, terminate RS422/485. **** No respond - message if buc2 not connected.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.2.1.5.1 |
buc2PwrAlarmThreshSets/Gets power alarm threshold. **** No respond - message if buc2 not connected.rw DisplayString UNITS "dB" .1.3.6.1.4.1.23304.2.2.2.1.5.2 |
buc2BurstPwrThreshSets/Gets burst power threshold. **** No respond - message if buc2 not connected.rw DisplayString UNITS "dB" .1.3.6.1.4.1.23304.2.2.2.1.5.3 |
buc2RefSourceSets/Gets reference source 0-external, 1-internal (Only for RBUC). **** No respond - message if buc2 not connected.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.2.1.5.4 |
buc2LEDStateSets/Gets LEDs status on/off (Only for RBUC). **** No respond - message if buc2 not connected.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.2.1.5.5 |
buc2Status OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.2.2 |
buc2PaStatusGets to 1 when PA is on. Respond -1 if buc2 not connected.ro INTEGER .1.3.6.1.4.1.23304.2.2.2.2.1 |
buc2TxPowerGets Tx power format x.x dB. **** No respond - message if buc2 not connected.ro DisplayString UNITS "dB" .1.3.6.1.4.1.23304.2.2.2.2.2 |
buc2TxBurstPowerGets Tx power. Format is x.x,y.y,z.z, where x.x is current burst power, y.y is min and z.z is max burts power. **** No respond - message if buc2 not connected.ro DisplayString UNITS "dB" .1.3.6.1.4.1.23304.2.2.2.2.3 |
buc2FaultsGets the current fault status. Format - Bit0 PA fault, Bit1 Fan fault, Bit2 Power fault, Bit3 Temp fault, Bit4 10MHz fault, Bit5 Internal fault Bit6 LNB fault, Bit7 Red'cy Cont fault. Respond -1 if buc2 not connected.ro INTEGER .1.3.6.1.4.1.23304.2.2.2.2.4 |
buc2LatchedFaultsGets the current latched faults. Format is same as Faults. Respond -1 if buc2 not connected.ro INTEGER .1.3.6.1.4.1.23304.2.2.2.2.5 |
buc2TemperatureGets the BUC temperature. Format is x.x. **** No respond - message if buc2 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.2.2.6 |
buc2MinMaxTemperatureGets the BUC temperature. Format is x.x,y.y where x.x is max and y.y is min temperature. **** No respond - message if buc2 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.2.2.7 |
buc2SystemSettingGets the current system status. Format is Bit0 - PA state, Bit1 - RS232 Tx, Bit2 - FSK Tx, Bit3 - RS485 Tx Bit4 - Redundancy mode, Bit5 - Online, Bit6..Bit7 - Redundancy cold or hot mode, Bit8 - HTTP Tx, Bit9 - TELNET Tx, Bit10 - SNMP Tx. Respond -1 if buc2 not connected.ro INTEGER .1.3.6.1.4.1.23304.2.2.2.2.8 |
buc2SystemPollGets the system poll status. Format is Bit0 - Fault, Bit1 - System change. Respond -1 if buc2 not connected.ro INTEGER .1.3.6.1.4.1.23304.2.2.2.2.9 |
buc2DeviceTypeGets the device type. Format is X,Y where X is the model and Y is software version. **** No respond - message if buc2 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.2.2.10 |
buc2GatewayGets the BUC gateway address (Only for RBUC). **** No respond - message if buc2 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.2.2.11 |
buc2IpAddressGets the BUC IP address (Only for RBUC). **** No respond - message if buc2 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.2.2.12 |
buc2MACAddressGets the BUC MAC address (Only for RBUC). **** No respond - message if buc2 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.2.2.13 |
buc2NetmaskGets the BUC netmask (Only for RBUC). **** No respond - message if buc2 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.2.2.14 |
buc2RefPowerGets the BUC reference power. **** No respond - message if buc2 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.2.2.15 |
buc2ConfigGets the BUC configuration. **** No respond - message if buc2 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.2.2.16 |
buc2BuildStandardGets the BUC build standard. **** No respond - message if buc2 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.2.2.17 |
buc2Info OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.2.3 |
buc2IdInfoGets the module firmware revision, serial number and model. This string will have a zero length if the revision is unknown. **** No respond - message if buc2 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.2.3.1 |
buc2LimitsGets the limit data for the BUC. Format is: Power meter MIN/MAX , IF,RF and LO frequencies. This string will have a zero length if the revision is unknown. **** No respond - message if buc2 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.2.3.2 |
buc2PktProtocolsInfoGets supported packet protocols and the corresponding address ranges. **** No respond - message if buc2 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.2.3.3 |
ctrl OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.3 |
settings OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.3.1 |
operationalModeSets 7586 operational mode - Auto, Manual Stream1, Stream2.rw INTEGER .1.3.6.1.4.1.23304.2.2.3.1.1 |
onlineStreamSets the online stream.rw INTEGER .1.3.6.1.4.1.23304.2.2.3.1.2 |
waveguideSwitchSets Waveguide switch Rx+Tx, Rx/Tx and Tx Only.rw INTEGER .1.3.6.1.4.1.23304.2.2.3.1.3 |
startupTimeSets Startup time.rw INTEGER .1.3.6.1.4.1.23304.2.2.3.1.4 |
lnbCurrentLimitSets LNB current limits.rw DisplayString UNITS "mA" .1.3.6.1.4.1.23304.2.2.3.1.5 |
ledStateSets 7586 LED.rw INTEGER .1.3.6.1.4.1.23304.2.2.3.1.6 |
refSourceSets 7586 reference state.rw INTEGER .1.3.6.1.4.1.23304.2.2.3.1.7 |
refTrimSets 7586 reference trim.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.3.1.8 |
refThreshSets 7586 reference alarm treshold.rw DisplayString UNITS "dBm" .1.3.6.1.4.1.23304.2.2.3.1.9 |
refPwrGets 7586 reference power.ro DisplayString UNITS "dBm" .1.3.6.1.4.1.23304.2.2.3.1.10 |
ipAddrGets the 7586 IP address.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.3.1.11 |
macAddressGets the 7586 MAC address.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.3.1.12 |
netmaskGets the 7586 netmask.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.3.1.13 |
gatewayGets the 7586 gateway address.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.3.1.14 |
status OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.3.2 |
lnbCurrentSets 7586 LNB current.ro DisplayString UNITS "mA" .1.3.6.1.4.1.23304.2.2.3.2.1 |
lnbVoltageSets 7586 LNB voltage.ro DisplayString UNITS "V" .1.3.6.1.4.1.23304.2.2.3.2.2 |
faultsGets the current fault status.ro INTEGER .1.3.6.1.4.1.23304.2.2.3.2.3 |
info OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.3.3 |
idInfoGets the module firmware revision, serial number and model. This string will have a zero length if the revision is unknown.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.3.3.1 |