RC7586-MIB
Imported Objects
Objects
111 total| Object Name |
|---|
rc7586MIBThe Structure of Management Information for the Codan enterprise. Copyright(c) 2009 All rights reserved MODULE-IDENTITY .1.3.6.1.4.1.23304.2.2 |
buc1 OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.1 |
buc1Configuration OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.1.1 |
buc1TxSettings OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.1.1.1 |
buc1TxOnSets Tx on/off. Respond -1 if buc1 not connected.rw INTEGER .1.3.6.1.4.1.23304.2.2.1.1.1.1 |
buc1TxDefaultSets Tx default 1-last 0-off. Respond -1 if buc1 not connected.rw INTEGER .1.3.6.1.4.1.23304.2.2.1.1.1.2 |
buc1TxAttenuatorSets/Gets Tx attenuation value in 1dBm steps. Respond -1 if buc1 not connected.rw INTEGER .1.3.6.1.4.1.23304.2.2.1.1.1.3 |
buc1PktProtocol OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.1.1.2 |
buc1ProtocolSets/Gets packet protocol 0 - ASCII, 1 - CODAN, 2 - SAbus, 3 - Comstream, 4 - NDSatcom. Respond -1 if buc1 not connected.rw INTEGER .1.3.6.1.4.1.23304.2.2.1.1.2.1 |
buc1AddressSets/Gets packet address: 0-31 NDSatcom ...Respond -1 if buc1 not connected.rw INTEGER .1.3.6.1.4.1.23304.2.2.1.1.2.2 |
buc1RCSetting OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.1.1.3 |
buc1ModeSets/Gets redundancy mode 0-none, 1-warm, 2-hot. Respond -1 if buc1 not connected.rw INTEGER .1.3.6.1.4.1.23304.2.2.1.1.3.1 |
buc1OnLineSets/Gets redundancy mode on on/off line state. Respond -1 if buc1 not connected.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.1.1.3.2 |
buc1Freqs OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.1.1.4 |
buc1RFFreqSets/Gets the RBUC RF frequency. Respond -1 if buc1 not connected.rw INTEGER UNITS "MHz" .1.3.6.1.4.1.23304.2.2.1.1.4.1 |
buc1IFFreqSets/Gets the RBUC IF frequency. Respond -1 if buc1 not connected.rw INTEGER UNITS "MHz" .1.3.6.1.4.1.23304.2.2.1.1.4.2 |
buc1LOFreqSets/Gets the RBUC LO frequency. Respond -1 if buc1 not connected.rw INTEGER UNITS "MHz" .1.3.6.1.4.1.23304.2.2.1.1.4.3 |
buc1Misc OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.1.1.5 |
buc1SerIfSets/Gets serial interface - rate, length, parity, stop, terminate RS422/485. **** No respond - message if buc1 not connected.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.1.1.5.1 |
buc1PwrAlarmThreshSets/Gets power alarm threshold. **** No respond - message if buc1 not connected.rw DisplayString UNITS "dB" .1.3.6.1.4.1.23304.2.2.1.1.5.2 |
buc1BurstPwrThreshSets/Gets burst power threshold. **** No respond - message if buc1 not connected.rw DisplayString UNITS "dB" .1.3.6.1.4.1.23304.2.2.1.1.5.3 |
buc1RefSourceSets/Gets reference source 0-external, 1-internal (Only for RBUC). **** No respond - message if buc1 not connected.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.1.1.5.4 |
buc1LEDStateSets/Gets LEDs status on/off (Only for RBUC). **** No respond - message if buc1 not connected.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.1.1.5.5 |
buc1Status OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.1.2 |
buc1PaStatusGets to 1 when PA is on. Respond -1 if buc1 not connected.ro INTEGER .1.3.6.1.4.1.23304.2.2.1.2.1 |
buc1TxPowerGets Tx power format x.x dB. **** No respond - message if buc1 not connected.ro DisplayString UNITS "dB" .1.3.6.1.4.1.23304.2.2.1.2.2 |
buc1TxBurstPowerGets Tx power. Format is x.x,y.y,z.z, where x.x is current burst power, y.y is min and z.z is max burts power. **** No respond - message if buc1 not connected.ro DisplayString UNITS "dB" .1.3.6.1.4.1.23304.2.2.1.2.3 |
buc1FaultsGets the current fault status. Format - Bit0 PA fault, Bit1 Fan fault, Bit2 Power fault, Bit3 Temp fault, Bit4 10MHz fault, Bit5 Internal fault Bit6 LNB fault, Bit7 Red'cy Cont fault. Respond -1 if buc2 not connected.ro INTEGER .1.3.6.1.4.1.23304.2.2.1.2.4 |
buc1LatchedFaultsGets the current latched faults. Format is same as Faults. Respond -1 if buc2 not connected.ro INTEGER .1.3.6.1.4.1.23304.2.2.1.2.5 |
buc1TemperatureGets the BUC temperature. Format is x.x. **** No respond - message if buc1 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.1.2.6 |
buc1MinMaxTemperatureGets the BUC temperature. Format is x.x,y.y where x.x is max and y.y is min temperature. **** No respond - message if buc1 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.1.2.7 |
buc1SystemSettingGets the current system status. Format is Bit0 - PA state, Bit1 - RS232 Tx, Bit2 - FSK Tx, Bit3 - RS485 Tx Bit4 - Redundancy mode, Bit5 - Online, Bit6..Bit7 - Redundancy cold or hot mode, Bit8 - HTTP Tx, Bit9 - TELNET Tx, Bit10 - SNMP Tx. Respond -1 if buc1 not connected.ro INTEGER .1.3.6.1.4.1.23304.2.2.1.2.8 |
buc1SystemPollGets the system poll status. Format is Bit0 - Fault, Bit1 - System change. Respond -1 if buc1 not connected.ro INTEGER .1.3.6.1.4.1.23304.2.2.1.2.9 |
buc1DeviceTypeGets the device type. Format is X,Y where X is the model and Y is software version. **** No respond - message if buc1 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.1.2.10 |
buc1GatewayGets the BUC gateway address (Only for RBUC). **** No respond - message if buc1 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.1.2.11 |
buc1IpAddressGets the BUC IP address (Only for RBUC). **** No respond - message if buc1 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.1.2.12 |
buc1MACAddressGets the BUC MAC address (Only for RBUC). **** No respond - message if buc1 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.1.2.13 |
buc1NetmaskGets the BUC netmask (Only for RBUC). **** No respond - message if buc1 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.1.2.14 |
buc1RefPowerGets the BUC reference power. **** No respond - message if buc1 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.1.2.15 |
buc1ConfigGets the BUC configuration. **** No respond - message if buc1 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.1.2.16 |
buc1BuildStandardGets the BUC build standard. **** No respond - message if buc1 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.1.2.17 |
buc1Info OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.1.3 |
buc1IdInfoGets the module firmware revision, serial number and model. This string will have a zero length if the revision is unknown. **** No respond - message if buc1 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.1.3.1 |
buc1LimitsGets the limit data for the BUC. Format is: Power meter MIN/MAX , IF,RF and LO frequencies. This string will have a zero length if the revision is unknown. **** No respond - message if buc1 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.1.3.2 |
buc1PktProtocolsInfoGets supported packet protocols and the corresponding address ranges. **** No respond - message if buc1 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.1.3.3 |
buc2 OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.2 |
buc2Configuration OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.2.1 |
buc2TxSettings OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.2.1.1 |
buc2TxOnSets Tx on/off. Respond -1 if buc2 not connected.rw INTEGER .1.3.6.1.4.1.23304.2.2.2.1.1.1 |
buc2TxDefaultSets Tx default 1-last 0-off. Respond -1 if buc2 not connected.rw INTEGER .1.3.6.1.4.1.23304.2.2.2.1.1.2 |
buc2TxAttenuatorSets/Gets Tx attenuation value in 1dBm steps. Respond -1 if buc2 not connected.rw INTEGER .1.3.6.1.4.1.23304.2.2.2.1.1.3 |
buc2PktProtocol OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.2.1.2 |
buc2ProtocolSets/Gets packet protocol 0 - ASCII, 1 - CODAN, 2 - SAbus, 3 - Comstream, 4 - NDSatcom. Respond -1 if buc2 not connected.rw INTEGER .1.3.6.1.4.1.23304.2.2.2.1.2.1 |
buc2AddressSets/Gets packet address: 0-31 NDSatcom ...Respond -1 if buc2 not connected.rw INTEGER .1.3.6.1.4.1.23304.2.2.2.1.2.2 |
buc2RCSetting OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.2.1.3 |
buc2ModeSets/Gets redundancy mode 0-none, 1-warm, 2-hot. Respond -1 if buc2 not connected.rw INTEGER .1.3.6.1.4.1.23304.2.2.2.1.3.1 |
buc2OnLineSets/Gets redundancy mode on on/off line state. Respond -1 if buc2 not connected.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.2.1.3.2 |
buc2Freqs OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.2.1.4 |
buc2RFFreqSets/Gets the RBUC RF frequency. Respond -1 if buc2 not connected.rw INTEGER UNITS "MHz" .1.3.6.1.4.1.23304.2.2.2.1.4.1 |
buc2IFFreqSets/Gets the RBUC IF frequency. Respond -1 if buc2 not connected.rw INTEGER UNITS "MHz" .1.3.6.1.4.1.23304.2.2.2.1.4.2 |
buc2LOFreqSets/Gets the RBUC LO frequency. Respond -1 if buc2 not connected.rw INTEGER UNITS "MHz" .1.3.6.1.4.1.23304.2.2.2.1.4.3 |
buc2Misc OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.2.1.5 |
buc2SerIfSets/Gets serial interface - rate, length, parity, stop, terminate RS422/485. **** No respond - message if buc2 not connected.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.2.1.5.1 |
buc2PwrAlarmThreshSets/Gets power alarm threshold. **** No respond - message if buc2 not connected.rw DisplayString UNITS "dB" .1.3.6.1.4.1.23304.2.2.2.1.5.2 |
buc2BurstPwrThreshSets/Gets burst power threshold. **** No respond - message if buc2 not connected.rw DisplayString UNITS "dB" .1.3.6.1.4.1.23304.2.2.2.1.5.3 |
buc2RefSourceSets/Gets reference source 0-external, 1-internal (Only for RBUC). **** No respond - message if buc2 not connected.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.2.1.5.4 |
buc2LEDStateSets/Gets LEDs status on/off (Only for RBUC). **** No respond - message if buc2 not connected.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.2.1.5.5 |
buc2Status OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.2.2 |
buc2PaStatusGets to 1 when PA is on. Respond -1 if buc2 not connected.ro INTEGER .1.3.6.1.4.1.23304.2.2.2.2.1 |
buc2TxPowerGets Tx power format x.x dB. **** No respond - message if buc2 not connected.ro DisplayString UNITS "dB" .1.3.6.1.4.1.23304.2.2.2.2.2 |
buc2TxBurstPowerGets Tx power. Format is x.x,y.y,z.z, where x.x is current burst power, y.y is min and z.z is max burts power. **** No respond - message if buc2 not connected.ro DisplayString UNITS "dB" .1.3.6.1.4.1.23304.2.2.2.2.3 |
buc2FaultsGets the current fault status. Format - Bit0 PA fault, Bit1 Fan fault, Bit2 Power fault, Bit3 Temp fault, Bit4 10MHz fault, Bit5 Internal fault Bit6 LNB fault, Bit7 Red'cy Cont fault. Respond -1 if buc2 not connected.ro INTEGER .1.3.6.1.4.1.23304.2.2.2.2.4 |
buc2LatchedFaultsGets the current latched faults. Format is same as Faults. Respond -1 if buc2 not connected.ro INTEGER .1.3.6.1.4.1.23304.2.2.2.2.5 |
buc2TemperatureGets the BUC temperature. Format is x.x. **** No respond - message if buc2 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.2.2.6 |
buc2MinMaxTemperatureGets the BUC temperature. Format is x.x,y.y where x.x is max and y.y is min temperature. **** No respond - message if buc2 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.2.2.7 |
buc2SystemSettingGets the current system status. Format is Bit0 - PA state, Bit1 - RS232 Tx, Bit2 - FSK Tx, Bit3 - RS485 Tx Bit4 - Redundancy mode, Bit5 - Online, Bit6..Bit7 - Redundancy cold or hot mode, Bit8 - HTTP Tx, Bit9 - TELNET Tx, Bit10 - SNMP Tx. Respond -1 if buc2 not connected.ro INTEGER .1.3.6.1.4.1.23304.2.2.2.2.8 |
buc2SystemPollGets the system poll status. Format is Bit0 - Fault, Bit1 - System change. Respond -1 if buc2 not connected.ro INTEGER .1.3.6.1.4.1.23304.2.2.2.2.9 |
buc2DeviceTypeGets the device type. Format is X,Y where X is the model and Y is software version. **** No respond - message if buc2 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.2.2.10 |
buc2GatewayGets the BUC gateway address (Only for RBUC). **** No respond - message if buc2 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.2.2.11 |
buc2IpAddressGets the BUC IP address (Only for RBUC). **** No respond - message if buc2 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.2.2.12 |
buc2MACAddressGets the BUC MAC address (Only for RBUC). **** No respond - message if buc2 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.2.2.13 |
buc2NetmaskGets the BUC netmask (Only for RBUC). **** No respond - message if buc2 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.2.2.14 |
buc2RefPowerGets the BUC reference power. **** No respond - message if buc2 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.2.2.15 |
buc2ConfigGets the BUC configuration. **** No respond - message if buc2 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.2.2.16 |
buc2BuildStandardGets the BUC build standard. **** No respond - message if buc2 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.2.2.17 |
buc2Info OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.2.3 |
buc2IdInfoGets the module firmware revision, serial number and model. This string will have a zero length if the revision is unknown. **** No respond - message if buc2 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.2.3.1 |
buc2LimitsGets the limit data for the BUC. Format is: Power meter MIN/MAX , IF,RF and LO frequencies. This string will have a zero length if the revision is unknown. **** No respond - message if buc2 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.2.3.2 |
buc2PktProtocolsInfoGets supported packet protocols and the corresponding address ranges. **** No respond - message if buc2 not connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.2.3.3 |
ctrl OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.3 |
settings OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.3.1 |
operationalModeSets 7586 operational mode - Auto, Manual Stream1, Stream2.rw INTEGER .1.3.6.1.4.1.23304.2.2.3.1.1 |
onlineStreamSets the online stream.rw INTEGER .1.3.6.1.4.1.23304.2.2.3.1.2 |
waveguideSwitchSets Waveguide switch Rx+Tx, Rx/Tx and Tx Only.rw INTEGER .1.3.6.1.4.1.23304.2.2.3.1.3 |
startupTimeSets Startup time.rw INTEGER .1.3.6.1.4.1.23304.2.2.3.1.4 |
lnbCurrentLimitSets LNB current limits.rw DisplayString UNITS "mA" .1.3.6.1.4.1.23304.2.2.3.1.5 |
ledStateSets 7586 LED.rw INTEGER .1.3.6.1.4.1.23304.2.2.3.1.6 |
refSourceSets 7586 reference state.rw INTEGER .1.3.6.1.4.1.23304.2.2.3.1.7 |
refTrimSets 7586 reference trim.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.3.1.8 |
refThreshSets 7586 reference alarm treshold.rw DisplayString UNITS "dBm" .1.3.6.1.4.1.23304.2.2.3.1.9 |
refPwrGets 7586 reference power.ro DisplayString UNITS "dBm" .1.3.6.1.4.1.23304.2.2.3.1.10 |
ipAddrGets the 7586 IP address.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.3.1.11 |
macAddressGets the 7586 MAC address.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.3.1.12 |
netmaskGets the 7586 netmask.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.3.1.13 |
gatewayGets the 7586 gateway address.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.3.1.14 |
status OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.3.2 |
lnbCurrentSets 7586 LNB current.ro DisplayString UNITS "mA" .1.3.6.1.4.1.23304.2.2.3.2.1 |
lnbVoltageSets 7586 LNB voltage.ro DisplayString UNITS "V" .1.3.6.1.4.1.23304.2.2.3.2.2 |
faultsGets the current fault status.ro INTEGER .1.3.6.1.4.1.23304.2.2.3.2.3 |
info OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.2.3.3 |
idInfoGets the module firmware revision, serial number and model. This string will have a zero length if the revision is unknown.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.2.3.3.1 |
More MIBs from Codan Limited
Browse all Codan LimitedMIBs →The CODAN-MIB module provides vendor-specific management objects and traps for the Codan 8800 DMR radio device, enabling monitoring of link settings, interface status, relay tables, external inputs, and alarm controls. It complements standard MIB-II, Interfaces, DS1/E1, DS3/E3, RS-232, and Ethernet statistics to facilitate comprehensive telemetry of the device's physical layer performance and operational state.
The RBUC-MIB facilitates SNMP-based monitoring and management of Codan enterprise radio communication infrastructure, specifically tracking device status, link quality metrics, and transmission parameters for Codan's radio units. This module enables the collection of operational data such as signal strength, error rates, and interface states to support network availability and performance analysis.
The CODAN-SMI module defines the Structure of Management Information schema for Codan enterprise communication hardware, specifically enabling the monitoring of radio system states, channel utilization, and link performance metrics via SNMP. It serves as the foundational definition set for Codan's proprietary management objects, allowing network management systems to retrieve operational data from Codan radios and associated infrastructure.