RBUC-MIB
The Structure of Management Information for the Codan enterprise. Copyright(c) 2009 All rights reserved
Main OID:
rbucMIB.1.3.6.1.4.1.23304.2.1
45
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
45 total| Object Name |
|---|
rbucMIBThe Structure of Management Information for the Codan enterprise. Copyright(c) 2009 All rights reserved MODULE-IDENTITY .1.3.6.1.4.1.23304.2.1 |
configuration OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.1.1 |
txSettings OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.1.1.1 |
txOnSets Tx on/off.rw INTEGER .1.3.6.1.4.1.23304.2.1.1.1.1 |
txDefaultSets Tx default 1-last 0-off.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.23304.2.1.1.1.2 |
txAttenuatorSets/Gets Tx attenuation value in 1dBm steps.rw INTEGER .1.3.6.1.4.1.23304.2.1.1.1.3 |
pktProtocol OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.1.1.2 |
protocolSets/Gets packet protocol 0 - ASCII, 1 - CODAN, 2 - .rw INTEGER .1.3.6.1.4.1.23304.2.1.1.2.1 |
addressSets/Gets packet address: 0-31 NDSatcom ...rw INTEGER .1.3.6.1.4.1.23304.2.1.1.2.2 |
rcSetting OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.1.1.3 |
modeSets/Gets redundancy mode 0-none, 1-warm, 2-hot.rw INTEGER .1.3.6.1.4.1.23304.2.1.1.3.1 |
onLineSets/Gets redundancy mode on on/off line state.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.23304.2.1.1.3.2 |
freqs OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.1.1.4 |
rfFreqSets/Gets the RBUC RF frequency.rw INTEGER UNITS "MHz" .1.3.6.1.4.1.23304.2.1.1.4.1 |
ifFreqSets/Gets the RBUC IF frequency.rw INTEGER UNITS "MHz" .1.3.6.1.4.1.23304.2.1.1.4.2 |
loFreqSets/Gets the RBUC LO frequency.rw INTEGER UNITS "MHz" .1.3.6.1.4.1.23304.2.1.1.4.3 |
misc OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.1.1.5 |
serIfSets/Gets serial interface - rate, length, parity, stop, terminate RS422/485.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.1.1.5.1 |
serEchoSets/Gets serial interface echo on/off.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.23304.2.1.1.5.2 |
pwrAlarmThreshSets/Gets power alarm threshold.rw DisplayString UNITS "dB" .1.3.6.1.4.1.23304.2.1.1.5.3 |
burstPwrThreshSets/Gets burst power threshold.rw DisplayString UNITS "dB" .1.3.6.1.4.1.23304.2.1.1.5.4 |
refSourceSets/Gets reference source 0-external, 1-internal.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.23304.2.1.1.5.5 |
ledStateSetS/Gets LEDs status on/off.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.23304.2.1.1.5.6 |
status OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.1.2 |
paStatusGets to 1 when PA is on.ro Enumeration .1.3.6.1.4.1.23304.2.1.2.1 |
txPowerGets Tx power format x.x dB.ro DisplayString UNITS "dB" .1.3.6.1.4.1.23304.2.1.2.2 |
txBurstPowerGets Tx power. Format is x.x,y.y,z.z, where x.x is current burst power, y.y is min and z.z is max burts power.ro DisplayString UNITS "dB" .1.3.6.1.4.1.23304.2.1.2.3 |
faultsGets the current fault status. Format - Bit0 PA fault, Bit1 Fan fault, Bit2 Power fault, Bit3 Temp fault, Bit4 10MHz fault, Bit5 Internal fault Bit6 LNB fault, Bit7 Red'cy Cont fault.ro INTEGER .1.3.6.1.4.1.23304.2.1.2.4 |
latchedFaultsGets the current latched faults. Format is same as Faults.ro INTEGER .1.3.6.1.4.1.23304.2.1.2.5 |
temperatureGets the BUC temperature. Format is x.x.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.1.2.6 |
minMaxTemperatureGets the BUC temperature. Format is x.x,y.y where x.x is max and y.y is min temperature.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.1.2.7 |
systemSettingGets the current system status. Format is Bit0 - PA state, Bit1 - RS232 Tx, Bit2 - FSK Tx, Bit3 - RS485 Tx Bit4 - Redundancy mode, Bit5 - Online, Bit6..Bit7 - Redundancy cold or hot mode, Bit8 - HTTP Tx, Bit9 - TELNET Tx, Bit10 - SNMP Tx.ro INTEGER .1.3.6.1.4.1.23304.2.1.2.8 |
systemPollGets the system poll status. Format is Bit0 - Fault, Bit1 - System change.ro INTEGER .1.3.6.1.4.1.23304.2.1.2.9 |
deviceTypeGets the device type. Format is X,Y where X is the model and Y is software version.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.1.2.10 |
gatewayGets the BUC gateway address.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.1.2.11 |
ipAddrGets the BUC IP address.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.1.2.12 |
macAddressGets the BUC MAC address.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.1.2.13 |
netmaskGets the BUC netmask.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.1.2.14 |
refPowerGets the BUC reference power.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.1.2.15 |
bucConfigurationGets the BUC configuration.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.1.2.16 |
buildStandardGets the BUC build standard.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.1.2.17 |
info OBJECT IDENTIFIER .1.3.6.1.4.1.23304.2.1.3 |
idInfoGets the module firmware revision, serial number and model. This string will have a zero length if the revision is unknown.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.1.3.1 |
limitsGets the limit data for the BUC. Format is: Power meter MIN/MAX , IF,RF and LO frequencies. This string will have a zero length if the revision is unknown.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.1.3.2 |
pktProtocolsInfoGets supported packet protocols and the corresponding address ranges.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.23304.2.1.3.3 |