RAIDMANAGER-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for RAIDMANAGER-MIB.
83
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
83 total| Object Name |
|---|
dec OBJECT IDENTIFIER .1.3.6.1.4.1.36 |
RFC1155-SMI Unknown .1.3.6.1.4.1.36 |
ema OBJECT IDENTIFIER .1.3.6.1.4.1.36.2 |
sysobjids OBJECT IDENTIFIER .1.3.6.1.4.1.36.2.15 |
raidmanager OBJECT IDENTIFIER .1.3.6.1.4.1.36.2.15.21 |
diskFailureTrapA disk drive has failed.
Details:
A disk device has failed.
User Action:
Replace the disk device. TRAP-TYPE .1.3.6.1.4.1.36.2.15.21.0.1 |
diskInformationTrapA disk drive has recovered.
Details:
A disk device has recovered.
User Action:
None. TRAP-TYPE .1.3.6.1.4.1.36.2.15.21.0.2 |
powerSupplyFailureTrapOne power supply has failed.
Details:
The power supply in the specified location has failed.
User Action:
Replace power supply. TRAP-TYPE .1.3.6.1.4.1.36.2.15.21.0.3 |
powerSupplyInformationTrapPower supply has recovered.
Details:
The power supply in the specified location has gone from BAD to good.
User Action:
None. TRAP-TYPE .1.3.6.1.4.1.36.2.15.21.0.4 |
fanFailureTrapA fan has failed.
Details:
The fan in the specified location has failed.
User Action:
Replace fan. TRAP-TYPE .1.3.6.1.4.1.36.2.15.21.0.5 |
fanInformationTrapA fan has recovered.
Details:
The fan in the specified location has recovered.
User Action:
None. TRAP-TYPE .1.3.6.1.4.1.36.2.15.21.0.6 |
cacheBatteryFailureTrapA controller cache battery has failed.
Details:
The cache battery in specified location has failed.
User Action:
Replace cache battery or replenish charge. TRAP-TYPE .1.3.6.1.4.1.36.2.15.21.0.7 |
cacheBatteryLowTrapA controller cache battery has LOW state.
Details:
The cache battery in specified location has LOW state.
User Action:
Replace cache battery or replenish charge. TRAP-TYPE .1.3.6.1.4.1.36.2.15.21.0.8 |
cacheBatteryInformationTrapA controller cache battery has good state.
Details:
The cache battery in specified location has good state.
User Action:
None. TRAP-TYPE .1.3.6.1.4.1.36.2.15.21.0.9 |
temperatureOverThresholdTrapA temperature sensor has exceeded WARNING threshold limit.
Details:
The temperature sensor in the specified location has exceeded WARNING threshold limit.
User Action:
Lower environmental temperature or raise internal threshold limit depending upon application. TRAP-TYPE .1.3.6.1.4.1.36.2.15.21.0.10 |
temperatureInformationTrapA temperature sensor indicates temperature below WARNING threshold limit.
Details:
The temperature sensor in the specified location indicates below WARNING threshold limit.
User Action:
None. TRAP-TYPE .1.3.6.1.4.1.36.2.15.21.0.11 |
communicationFailureTrapCommunication with the subsystem has failed.
Details:
The Agent lost communication with subsystem.
User Action:
Possible causes are data path interruption,
communication LUN failure,
2 or more power supplies failed,
2 or more fans failed,
temperature overlimit,
both controllers failed. TRAP-TYPE .1.3.6.1.4.1.36.2.15.21.0.12 |
communicationInformationTrapCommunication with the subsystem has recovered.
Details:
The Agent recovered communication with subsystem.
User Action:
None. TRAP-TYPE .1.3.6.1.4.1.36.2.15.21.0.13 |
controllerFailureTrapThe Secondary Controller in the subsytem has failed.
Details:
The Secondary Controller has failed.
User Action:
Replace controller. Possible causes are PCMCIA memory card ejected,
controller physically removed,
actual hardware failure. TRAP-TYPE .1.3.6.1.4.1.36.2.15.21.0.14 |
controllerInformationTrapThe Secondary Controller in the subsytem has recovered.
Details:
The Secondary Controller has recovered.
User Action:
None. TRAP-TYPE .1.3.6.1.4.1.36.2.15.21.0.15 |
lunFailureTrapA LUN has failed.
Details:
The LUN has failed and is off-line.
User Action:
Possible cause is too many failed disk drives that make up the LUN,
the OS can no longer communicate with the LUN for other reasons. TRAP-TYPE .1.3.6.1.4.1.36.2.15.21.0.16 |
lunReconstructTrapA LUN has started the reconstruction process.
Details:
The LUN has started the reconstruction process but is available for normal use.
Possible causes are an available disk drive was created as a spare to be inserted into the set,
an existing spare was automatically added to the set for reconstruction upon failure of a member disk device.
User Action:
None. TRAP-TYPE .1.3.6.1.4.1.36.2.15.21.0.17 |
lunReducedTrapA LUN has become degraded.
Details:
A LUN has become degraded due to a member disk device failure.
User Action:
Replace the failed disk device; add a spare to the system to cause a reconstruct. TRAP-TYPE .1.3.6.1.4.1.36.2.15.21.0.18 |
lunInformationTrapA LUN has become optimal.
Details:
A LUN has become optimal due to a successful completion of the reconstruction process.
User Action:
None. TRAP-TYPE .1.3.6.1.4.1.36.2.15.21.0.19 |
externalInputFailureTrapThe user-defined External Input to the EMU indicates a failure.
Details:
The External Input to the EMU indicates a failure.
User Action:
If the state of the is FAILURE, then one of the user-defined external input
devices is reporting a problem. TRAP-TYPE .1.3.6.1.4.1.36.2.15.21.0.20 |
externalInputInformationTrapThe user-defined External Input to the EMU indicates a recovery.
Details:
The External Input to the EMU indicates a recovery.
User Action:
None. TRAP-TYPE .1.3.6.1.4.1.36.2.15.21.0.21 |
cacheBatteryStateUnknownTrapA controller cache battery has unknown state.
Details:
The cache battery in specified location has an unknown state.
User Action:
None. TRAP-TYPE .1.3.6.1.4.1.36.2.15.21.0.22 |
agent OBJECT IDENTIFIER .1.3.6.1.4.1.36.2.15.21.1 |
agManufacturerThe name of the Enterprise Storage Manager Agent manufacturer.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.36.2.15.21.1.1 |
agMajVersionEnterprise Storage Manager Agent Major Version Number (e.g., 3
for 3.0).ro INTEGER .1.3.6.1.4.1.36.2.15.21.1.2 |
agMinVersionEnterprise Storage Manager Agent Minor Version Number (e.g., 0
for 3.0).ro INTEGER .1.3.6.1.4.1.36.2.15.21.1.3 |
agHostNameThe Host System Network Name where the agent resides.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.36.2.15.21.1.4 |
agEnterpriseThe Enterprise ID subtree for Enterprise Storage Manager Agent MIB
is registered.ro OBJECT IDENTIFIER .1.3.6.1.4.1.36.2.15.21.1.5 |
agDescriptionThe Enterprise Array Storage Agent description.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.36.2.15.21.1.6 |
workstation OBJECT IDENTIFIER .1.3.6.1.4.1.36.2.15.21.2 |
wsCPUThe workstation CPU type (e.g., 80486).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.36.2.15.21.2.1 |
wsComputerTypeThe workstation Computer type (e.g., PC/AT).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.36.2.15.21.2.2 |
wsModelThe workstation model number.ro INTEGER .1.3.6.1.4.1.36.2.15.21.2.3 |
wsSubModelThe workstation submodel number.ro INTEGER .1.3.6.1.4.1.36.2.15.21.2.4 |
wsBiosVersionThe workstation BIOS Version.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.36.2.15.21.2.5 |
wsOSThe workstation operating system name (e.g., WINNT).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.36.2.15.21.2.6 |
wsOSMajVersionThe workstation OS major version number
(e.g., 3 for WINNT 3.51).ro INTEGER .1.3.6.1.4.1.36.2.15.21.2.7 |
wsOSMinVersionThe workstation OS minor version number (e.g., 51 for
WINNT 3.51).ro INTEGER .1.3.6.1.4.1.36.2.15.21.2.8 |
subsys OBJECT IDENTIFIER .1.3.6.1.4.1.36.2.15.21.3 |
ssTotalSubSystemsThe total number of subsystems presently serviced
by this agent.ro INTEGER .1.3.6.1.4.1.36.2.15.21.3.1 |
ssStatusTableThis table holds the status information for
each subsystem. SEQUENCE OF SsEntry .1.3.6.1.4.1.36.2.15.21.3.2 |
ssEntryThe subsystem information entry. SsEntry .1.3.6.1.4.1.36.2.15.21.3.2.1 |
ssEntryIndexThe index into ssStatusTable .ro INTEGER .1.3.6.1.4.1.36.2.15.21.3.2.1.1 |
ssSubsysNameThe local Subsystem Name.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.36.2.15.21.3.2.1.2 |
ssOverallStatusThis variable reports the overall status of the
storage subsystem.
GREEN: Normal Operating Condition
YELLOW: Warning Condition
RED: Subsystem Communication Failure; No response to Agent requests.ro Enumeration .1.3.6.1.4.1.36.2.15.21.3.2.1.3 |
ssDiskStatusThis variable reports the overall status for the
physical devices in the subsystem.ro Enumeration .1.3.6.1.4.1.36.2.15.21.3.2.1.4 |
ssPowerStatusThis variable reports the status for the
Power Supply system in the subsystem.ro Enumeration .1.3.6.1.4.1.36.2.15.21.3.2.1.5 |
ssFanStatusThis variable reports the status for the
FAN system in the subsystem.ro Enumeration .1.3.6.1.4.1.36.2.15.21.3.2.1.6 |
ssCacheBatteryStatusThis variable reports the status for the
Cache Battery in the subsystem. This status object is currently
non-functional but in place for future use.ro Enumeration .1.3.6.1.4.1.36.2.15.21.3.2.1.7 |
ssTemperatureStatusThis variable reports the status for the
Temperature in the subsystem.ro Enumeration .1.3.6.1.4.1.36.2.15.21.3.2.1.8 |
ssCommStatusThis variable reports the status for the
communication to the Primary Controller.ro Enumeration .1.3.6.1.4.1.36.2.15.21.3.2.1.9 |
ssEmuExtInputStatusThis variable reports the status for the
EMU external input.ro Enumeration .1.3.6.1.4.1.36.2.15.21.3.2.1.10 |
ssEmuPresentThis variable reports the availability of the
Environment Monitoring Unit for the storage subsystem.ro Enumeration .1.3.6.1.4.1.36.2.15.21.3.2.1.11 |
ssController1StatusThis variable reports the status for the
Primary Controller.ro Enumeration .1.3.6.1.4.1.36.2.15.21.3.2.1.12 |
ssController1SerNumThe Primary Controller's Serial Number.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.36.2.15.21.3.2.1.13 |
ssController1RDACThe Primary Controller MODE.ro Enumeration .1.3.6.1.4.1.36.2.15.21.3.2.1.14 |
ssController1TypeThe Primary Controller's Type indicator.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.36.2.15.21.3.2.1.15 |
ssController1ProdIDThe Primary Controller's Product ID.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.36.2.15.21.3.2.1.16 |
ssController1FwRevThe Primary Controller's Firmware Revision.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.36.2.15.21.3.2.1.17 |
ssController1HwRevThe Primary Controller's Hardware Revision.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.36.2.15.21.3.2.1.18 |
ssController2StatusThis variable reports the status for the
Secondary Controller.ro Enumeration .1.3.6.1.4.1.36.2.15.21.3.2.1.19 |
ssController2SerNumThe Secondary Controller's Serial Number.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.36.2.15.21.3.2.1.20 |
ssController2RDACThe Secondary Controller MODE.ro Enumeration .1.3.6.1.4.1.36.2.15.21.3.2.1.21 |
ssController2TypeThe Secondary Controller's Type indicator.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.36.2.15.21.3.2.1.22 |
ssController2ProdIDThe Secondary Controller's Product ID.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.36.2.15.21.3.2.1.23 |
ssController2FwRevThe Secondary Controller's Firmware Revision.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.36.2.15.21.3.2.1.24 |
ssController2HwRevThe Secondary Controller's Hardware Revision.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.36.2.15.21.3.2.1.25 |
ssUpsStatusUninterruptable Power Supply status (Currently for future use).ro Enumeration .1.3.6.1.4.1.36.2.15.21.3.2.1.26 |
ssLunStatusLUN status.ro Enumeration .1.3.6.1.4.1.36.2.15.21.3.2.1.27 |
ssDiskNameThe name of disk with state change.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.36.2.15.21.3.2.1.28 |
ssPowerSupplyLocationThe location of power supply with state change.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.36.2.15.21.3.2.1.29 |
ssFanLocationThe location of fan with state change.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.36.2.15.21.3.2.1.30 |
ssCacheBatteryLocationThe location of controller cache battery with state change.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.36.2.15.21.3.2.1.31 |
ssTemperatureSensorLocationThe location of temperature sensor with state change.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.36.2.15.21.3.2.1.32 |
ssCabinetNumberThe current cabinet number which has FRU state change.ro INTEGER .1.3.6.1.4.1.36.2.15.21.3.2.1.33 |
ssLunNameThe name of the LUN with a state change.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.36.2.15.21.3.2.1.34 |
ssDiskPortThe current disk channel number.ro INTEGER .1.3.6.1.4.1.36.2.15.21.3.2.1.35 |
ssDiskTargetThe current disk SCSI Target ID.ro INTEGER .1.3.6.1.4.1.36.2.15.21.3.2.1.36 |