Home/Catalog/RAIDMANAGER-MIB

RAIDMANAGER-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for RAIDMANAGER-MIB.

83
Objects
Active
Status
3
Dependencies

Imported Objects

Objects

83 total
Object Name
dec
OBJECT IDENTIFIER
.1.3.6.1.4.1.36
RFC1155-SMI
Unknown
.1.3.6.1.4.1.36
ema
OBJECT IDENTIFIER
.1.3.6.1.4.1.36.2
sysobjids
OBJECT IDENTIFIER
.1.3.6.1.4.1.36.2.15
raidmanager
OBJECT IDENTIFIER
.1.3.6.1.4.1.36.2.15.21
diskFailureTrapA disk drive has failed. Details: A disk device has failed. User Action: Replace the disk device.
TRAP-TYPE
.1.3.6.1.4.1.36.2.15.21.0.1
diskInformationTrapA disk drive has recovered. Details: A disk device has recovered. User Action: None.
TRAP-TYPE
.1.3.6.1.4.1.36.2.15.21.0.2
powerSupplyFailureTrapOne power supply has failed. Details: The power supply in the specified location has failed. User Action: Replace power supply.
TRAP-TYPE
.1.3.6.1.4.1.36.2.15.21.0.3
powerSupplyInformationTrapPower supply has recovered. Details: The power supply in the specified location has gone from BAD to good. User Action: None.
TRAP-TYPE
.1.3.6.1.4.1.36.2.15.21.0.4
fanFailureTrapA fan has failed. Details: The fan in the specified location has failed. User Action: Replace fan.
TRAP-TYPE
.1.3.6.1.4.1.36.2.15.21.0.5
fanInformationTrapA fan has recovered. Details: The fan in the specified location has recovered. User Action: None.
TRAP-TYPE
.1.3.6.1.4.1.36.2.15.21.0.6
cacheBatteryFailureTrapA controller cache battery has failed. Details: The cache battery in specified location has failed. User Action: Replace cache battery or replenish charge.
TRAP-TYPE
.1.3.6.1.4.1.36.2.15.21.0.7
cacheBatteryLowTrapA controller cache battery has LOW state. Details: The cache battery in specified location has LOW state. User Action: Replace cache battery or replenish charge.
TRAP-TYPE
.1.3.6.1.4.1.36.2.15.21.0.8
cacheBatteryInformationTrapA controller cache battery has good state. Details: The cache battery in specified location has good state. User Action: None.
TRAP-TYPE
.1.3.6.1.4.1.36.2.15.21.0.9
temperatureOverThresholdTrapA temperature sensor has exceeded WARNING threshold limit. Details: The temperature sensor in the specified location has exceeded WARNING threshold limit. User Action: Lower environmental temperature or raise internal threshold limit depending upon application.
TRAP-TYPE
.1.3.6.1.4.1.36.2.15.21.0.10
temperatureInformationTrapA temperature sensor indicates temperature below WARNING threshold limit. Details: The temperature sensor in the specified location indicates below WARNING threshold limit. User Action: None.
TRAP-TYPE
.1.3.6.1.4.1.36.2.15.21.0.11
communicationFailureTrapCommunication with the subsystem has failed. Details: The Agent lost communication with subsystem. User Action: Possible causes are data path interruption, communication LUN failure, 2 or more power supplies failed, 2 or more fans failed, temperature overlimit, both controllers failed.
TRAP-TYPE
.1.3.6.1.4.1.36.2.15.21.0.12
communicationInformationTrapCommunication with the subsystem has recovered. Details: The Agent recovered communication with subsystem. User Action: None.
TRAP-TYPE
.1.3.6.1.4.1.36.2.15.21.0.13
controllerFailureTrapThe Secondary Controller in the subsytem has failed. Details: The Secondary Controller has failed. User Action: Replace controller. Possible causes are PCMCIA memory card ejected, controller physically removed, actual hardware failure.
TRAP-TYPE
.1.3.6.1.4.1.36.2.15.21.0.14
controllerInformationTrapThe Secondary Controller in the subsytem has recovered. Details: The Secondary Controller has recovered. User Action: None.
TRAP-TYPE
.1.3.6.1.4.1.36.2.15.21.0.15
lunFailureTrapA LUN has failed. Details: The LUN has failed and is off-line. User Action: Possible cause is too many failed disk drives that make up the LUN, the OS can no longer communicate with the LUN for other reasons.
TRAP-TYPE
.1.3.6.1.4.1.36.2.15.21.0.16
lunReconstructTrapA LUN has started the reconstruction process. Details: The LUN has started the reconstruction process but is available for normal use. Possible causes are an available disk drive was created as a spare to be inserted into the set, an existing spare was automatically added to the set for reconstruction upon failure of a member disk device. User Action: None.
TRAP-TYPE
.1.3.6.1.4.1.36.2.15.21.0.17
lunReducedTrapA LUN has become degraded. Details: A LUN has become degraded due to a member disk device failure. User Action: Replace the failed disk device; add a spare to the system to cause a reconstruct.
TRAP-TYPE
.1.3.6.1.4.1.36.2.15.21.0.18
lunInformationTrapA LUN has become optimal. Details: A LUN has become optimal due to a successful completion of the reconstruction process. User Action: None.
TRAP-TYPE
.1.3.6.1.4.1.36.2.15.21.0.19
externalInputFailureTrapThe user-defined External Input to the EMU indicates a failure. Details: The External Input to the EMU indicates a failure. User Action: If the state of the is FAILURE, then one of the user-defined external input devices is reporting a problem.
TRAP-TYPE
.1.3.6.1.4.1.36.2.15.21.0.20
externalInputInformationTrapThe user-defined External Input to the EMU indicates a recovery. Details: The External Input to the EMU indicates a recovery. User Action: None.
TRAP-TYPE
.1.3.6.1.4.1.36.2.15.21.0.21
cacheBatteryStateUnknownTrapA controller cache battery has unknown state. Details: The cache battery in specified location has an unknown state. User Action: None.
TRAP-TYPE
.1.3.6.1.4.1.36.2.15.21.0.22
agent
OBJECT IDENTIFIER
.1.3.6.1.4.1.36.2.15.21.1
agManufacturerThe name of the Enterprise Storage Manager Agent manufacturer.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.36.2.15.21.1.1
agMajVersionEnterprise Storage Manager Agent Major Version Number (e.g., 3 for 3.0).ro
INTEGER
.1.3.6.1.4.1.36.2.15.21.1.2
agMinVersionEnterprise Storage Manager Agent Minor Version Number (e.g., 0 for 3.0).ro
INTEGER
.1.3.6.1.4.1.36.2.15.21.1.3
agHostNameThe Host System Network Name where the agent resides.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.36.2.15.21.1.4
agEnterpriseThe Enterprise ID subtree for Enterprise Storage Manager Agent MIB is registered.ro
OBJECT IDENTIFIER
.1.3.6.1.4.1.36.2.15.21.1.5
agDescriptionThe Enterprise Array Storage Agent description.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.36.2.15.21.1.6
workstation
OBJECT IDENTIFIER
.1.3.6.1.4.1.36.2.15.21.2
wsCPUThe workstation CPU type (e.g., 80486).ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.36.2.15.21.2.1
wsComputerTypeThe workstation Computer type (e.g., PC/AT).ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.36.2.15.21.2.2
wsModelThe workstation model number.ro
INTEGER
.1.3.6.1.4.1.36.2.15.21.2.3
wsSubModelThe workstation submodel number.ro
INTEGER
.1.3.6.1.4.1.36.2.15.21.2.4
wsBiosVersionThe workstation BIOS Version.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.36.2.15.21.2.5
wsOSThe workstation operating system name (e.g., WINNT).ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.36.2.15.21.2.6
wsOSMajVersionThe workstation OS major version number (e.g., 3 for WINNT 3.51).ro
INTEGER
.1.3.6.1.4.1.36.2.15.21.2.7
wsOSMinVersionThe workstation OS minor version number (e.g., 51 for WINNT 3.51).ro
INTEGER
.1.3.6.1.4.1.36.2.15.21.2.8
subsys
OBJECT IDENTIFIER
.1.3.6.1.4.1.36.2.15.21.3
ssTotalSubSystemsThe total number of subsystems presently serviced by this agent.ro
INTEGER
.1.3.6.1.4.1.36.2.15.21.3.1
ssStatusTableThis table holds the status information for each subsystem.
SEQUENCE OF SsEntry
.1.3.6.1.4.1.36.2.15.21.3.2
ssEntryThe subsystem information entry.
SsEntry
.1.3.6.1.4.1.36.2.15.21.3.2.1
ssEntryIndexThe index into ssStatusTable .ro
INTEGER
.1.3.6.1.4.1.36.2.15.21.3.2.1.1
ssSubsysNameThe local Subsystem Name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.36.2.15.21.3.2.1.2
ssOverallStatusThis variable reports the overall status of the storage subsystem. GREEN: Normal Operating Condition YELLOW: Warning Condition RED: Subsystem Communication Failure; No response to Agent requests.ro
Enumeration
.1.3.6.1.4.1.36.2.15.21.3.2.1.3
ssDiskStatusThis variable reports the overall status for the physical devices in the subsystem.ro
Enumeration
.1.3.6.1.4.1.36.2.15.21.3.2.1.4
ssPowerStatusThis variable reports the status for the Power Supply system in the subsystem.ro
Enumeration
.1.3.6.1.4.1.36.2.15.21.3.2.1.5
ssFanStatusThis variable reports the status for the FAN system in the subsystem.ro
Enumeration
.1.3.6.1.4.1.36.2.15.21.3.2.1.6
ssCacheBatteryStatusThis variable reports the status for the Cache Battery in the subsystem. This status object is currently non-functional but in place for future use.ro
Enumeration
.1.3.6.1.4.1.36.2.15.21.3.2.1.7
ssTemperatureStatusThis variable reports the status for the Temperature in the subsystem.ro
Enumeration
.1.3.6.1.4.1.36.2.15.21.3.2.1.8
ssCommStatusThis variable reports the status for the communication to the Primary Controller.ro
Enumeration
.1.3.6.1.4.1.36.2.15.21.3.2.1.9
ssEmuExtInputStatusThis variable reports the status for the EMU external input.ro
Enumeration
.1.3.6.1.4.1.36.2.15.21.3.2.1.10
ssEmuPresentThis variable reports the availability of the Environment Monitoring Unit for the storage subsystem.ro
Enumeration
.1.3.6.1.4.1.36.2.15.21.3.2.1.11
ssController1StatusThis variable reports the status for the Primary Controller.ro
Enumeration
.1.3.6.1.4.1.36.2.15.21.3.2.1.12
ssController1SerNumThe Primary Controller's Serial Number.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.36.2.15.21.3.2.1.13
ssController1RDACThe Primary Controller MODE.ro
Enumeration
.1.3.6.1.4.1.36.2.15.21.3.2.1.14
ssController1TypeThe Primary Controller's Type indicator.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.36.2.15.21.3.2.1.15
ssController1ProdIDThe Primary Controller's Product ID.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.36.2.15.21.3.2.1.16
ssController1FwRevThe Primary Controller's Firmware Revision.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.36.2.15.21.3.2.1.17
ssController1HwRevThe Primary Controller's Hardware Revision.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.36.2.15.21.3.2.1.18
ssController2StatusThis variable reports the status for the Secondary Controller.ro
Enumeration
.1.3.6.1.4.1.36.2.15.21.3.2.1.19
ssController2SerNumThe Secondary Controller's Serial Number.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.36.2.15.21.3.2.1.20
ssController2RDACThe Secondary Controller MODE.ro
Enumeration
.1.3.6.1.4.1.36.2.15.21.3.2.1.21
ssController2TypeThe Secondary Controller's Type indicator.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.36.2.15.21.3.2.1.22
ssController2ProdIDThe Secondary Controller's Product ID.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.36.2.15.21.3.2.1.23
ssController2FwRevThe Secondary Controller's Firmware Revision.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.36.2.15.21.3.2.1.24
ssController2HwRevThe Secondary Controller's Hardware Revision.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.36.2.15.21.3.2.1.25
ssUpsStatusUninterruptable Power Supply status (Currently for future use).ro
Enumeration
.1.3.6.1.4.1.36.2.15.21.3.2.1.26
ssLunStatusLUN status.ro
Enumeration
.1.3.6.1.4.1.36.2.15.21.3.2.1.27
ssDiskNameThe name of disk with state change.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.36.2.15.21.3.2.1.28
ssPowerSupplyLocationThe location of power supply with state change.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.36.2.15.21.3.2.1.29
ssFanLocationThe location of fan with state change.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.36.2.15.21.3.2.1.30
ssCacheBatteryLocationThe location of controller cache battery with state change.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.36.2.15.21.3.2.1.31
ssTemperatureSensorLocationThe location of temperature sensor with state change.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.36.2.15.21.3.2.1.32
ssCabinetNumberThe current cabinet number which has FRU state change.ro
INTEGER
.1.3.6.1.4.1.36.2.15.21.3.2.1.33
ssLunNameThe name of the LUN with a state change.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.36.2.15.21.3.2.1.34
ssDiskPortThe current disk channel number.ro
INTEGER
.1.3.6.1.4.1.36.2.15.21.3.2.1.35
ssDiskTargetThe current disk SCSI Target ID.ro
INTEGER
.1.3.6.1.4.1.36.2.15.21.3.2.1.36