PoE-MIB
The Structure of PoE management for the proprietary enterprise.
Main OID:
swPoEMIB.dlink-common-mgmt.24
44
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
44 total| Object Name |
|---|
swPoEMIBThe Structure of PoE management for the
proprietary enterprise. MODULE-IDENTITY .dlink-common-mgmt.24 |
swPoESystemCtrl OBJECT IDENTIFIER .dlink-common-mgmt.24.1 |
swPoESystemPowerLimitThe power budget (in watts) of the PoE sytem.rw INTEGER .dlink-common-mgmt.24.1.1 |
swPoESystemPowerDisconnectMethodThe power management disconnection method. When the total consumed
power exceeds the power budget, the PoE controller initiates port disconnection,
to prevent overloading the power supply. The controller uses one of the
following two ways to implement the disconnection.
deny_next_port:
after the power budget has been exceeded, the next port
attempting to power up is denied, regardless of its priority.
deny_low_priority_port:
after the power budget has been exceeded, the next
port attempting to power up causes the port with the lowest priority
to shut down to allow high-priority ports to power up.
The default setting is deny_next_port.rw Enumeration .dlink-common-mgmt.24.1.2 |
swPoESystemManagementModeThis mode can be either power_limit mode or auto mode.
power_limit: If power supplied to the port exceeds the power limit
specified for it, this port will be shut down.
auto: The system will automatically determine the PD class of the
device connected to the port in the first stage. Normally, the PD
can be classified as class 1, 2, or 3. If the PD cannot be classified,
it will be classified as class 0. For class 0, it will assume that the PD
may consume the max power allowed. During the power feeding stage, if the power
supplied to the port exceeds the upper limit of the detected PD class, this
port will be shut down. For the upper limit for each class, it is 4W for
class 1 PD class, 7W for class 2, and 15.4W for class 3 PD and class 0 PD.rw Enumeration .dlink-common-mgmt.24.1.3 |
swPoESystemLedModeSpecifies if the system mode will be POE or NORMAL.rw Enumeration .dlink-common-mgmt.24.1.4 |
swPoESystemCtrlLegacyPDThe legacy PD detection state. Enables or disables legacy PD detection on all PoE port.rw Enumeration .dlink-common-mgmt.24.1.6 |
swPoESystemStackingCtrlTableA table that is used to configure PoE system information based on Unit ID.
The Unit ID is used for stacking. SEQUENCE OF SwPoESystemStackingCtrlEntry .dlink-common-mgmt.24.1.11 |
swPoESystemStackingCtrlEntryA list of PoE system information based on Unit ID. SwPoESystemStackingCtrlEntry .dlink-common-mgmt.24.1.11.1 |
swPoESystemStackingCtrlUnitIdThis object indicates the device's Unit ID.
A unit ID of zero denotes a stand-alone device.ro INTEGER .dlink-common-mgmt.24.1.11.1.1 |
swPoESystemStackingCtrlPowerLimitThe power budget (in watts) of the PoE sytem.rw INTEGER .dlink-common-mgmt.24.1.11.1.2 |
swPoESystemStackingCtrlPowerDisconnectMethodThe power management disconnection method. When the total consumed power
exceeds the power budget, the PoE controller initiates port disconnection
to prevent overloading the power supply. The controller uses one of the
following two ways to implement the disconnection.
deny_next_port:
after the power budget has been exceeded, the next port
attempting to power up is denied, regardless of its priority.
deny_low_priority_port:
after the power budget has been exceeded, the next
port attempting to power up causes the port with the lowest priority to
shut down to allow high-priority ports to power up.
The default setting is deny_next_port.rw Enumeration .dlink-common-mgmt.24.1.11.1.3 |
swPoESystemStackingCtrlManagementModeThis mode can be either power_limit mode or auto mode.
power_limit: If power supplied to the port exceeds the power limit
specified for it, this port will be shut down.
auto: The system will automatically determine the PD class of the
device connected to the port in the first stage. Normally, the PD
can be classified as class 1, 2, or 3. If the PD can not be classified,
it will be classified as class 0. For class 0, it will assume that the PD
may consume the max power allowed. At the power feeding stage, if the power
supplied to the port exceeds the upper limit of the detected PD class, this
port will be shut down. For the upper limit for each class, it is 4W for
class 1 PD class, 7W for class 2, and 15.4W for class 3 PD and class 0 PD.rw Enumeration .dlink-common-mgmt.24.1.11.1.4 |
swPoESystemStackingCtrlLedModeSpecifies the system mode to be POE or NORMAL.rw Enumeration .dlink-common-mgmt.24.1.11.1.5 |
swPoESystemStackingCtrlLegacyPDThe legacy PD detection state. Enables or disables legacy PD detection on PoE unit.rw Enumeration .dlink-common-mgmt.24.1.11.1.6 |
swPoESystemInfo OBJECT IDENTIFIER .dlink-common-mgmt.24.2 |
swPoESystemInfoTableA table that contains PoE system information based on Unit ID.
The Unit ID is used for stacking. SEQUENCE OF SwPoESystemInfoEntry .dlink-common-mgmt.24.2.1 |
swPoESystemInfoEntryA list of PoE system information based on Unit ID. SwPoESystemInfoEntry .dlink-common-mgmt.24.2.1.1 |
swPoESystemInfoUnitIdThis object indicates the device's Unit ID.
A unit ID of zero denotes a stand-alone device.ro INTEGER .dlink-common-mgmt.24.2.1.1.1 |
swPoESystemInfoPowerConsumptionThe actual momentary power consumption (in watts) in the PoE system.ro INTEGER .dlink-common-mgmt.24.2.1.1.2 |
swPoESystemInfoPowerRemainedThe actual momentary remaining power (in watts) in the PoE system.ro INTEGER .dlink-common-mgmt.24.2.1.1.3 |
swPoESystemInfoPowerLimitThe power budget (in watts) of the PoE sytem.ro INTEGER .dlink-common-mgmt.24.2.1.1.4 |
swPoESystemInfoPowerDisconnectMethodThe power management disconnection method. When the total consumed power
exceeds the power budget, the PoE controller initiates port disconnection
to prevent overloading the power supply. The controller uses one of the
following two ways to implement the disconnection.
deny_next_port:
after the power budget has been exceeded, the next port
attempting to power up is denied, regardless of its priority.
deny_low_priority_port:
after the power budget has been exceeded, the next
port attempting to power up causes the port with the lowest priority to
shut down to allow high-priority ports to power up.
The default setting is deny_next_port.ro Enumeration .dlink-common-mgmt.24.2.1.1.5 |
swPoESystemInfoManagementModeThis mode can be either power_limit mode or auto mode.
power_limit: If power supplied to the port exceeds the power limit
specified for it, this port will be shut down.
auto: The system will automatically determine the PD class of the
device connected to the port in the first stage. Normally, the PD
can be classified as class 1, 2, or 3. If the PD can not be classified,
it will be classified as class 0. For class 0, it will assume that the PD
may consume the max power allowed. At the power feeding stage, if the power
supplied to the port exceeds the upper limit of the detected PD class, this
port will be shut down. For the upper limit for each class, it is 4W for
class 1 PD class, 7W for class 2, and 15.4W for class 3 PD and class 0 PD.ro Enumeration .dlink-common-mgmt.24.2.1.1.6 |
swPoESystemInfoLegacyPDThe current status of legacy PD detection.ro Enumeration .dlink-common-mgmt.24.2.1.1.7 |
swPoEPortCtrl OBJECT IDENTIFIER .dlink-common-mgmt.24.3 |
swPoEPortCtrlTableA table that contains PoE configuration about every port in this stack.
If a device has N ports, then the 1
N+1
2N+1
...... SEQUENCE OF SwPoEPortCtrlEntry .dlink-common-mgmt.24.3.1 |
swPoEPortCtrlEntryA list of PoE configurations for each port of the device in this stack. SwPoEPortCtrlEntry .dlink-common-mgmt.24.3.1.1 |
swPoEPortCtrlPortIndexThis object indicates the devices' port number in this stack.
If a device has N ports, then the 1
N+1
2N+1
......ro INTEGER .dlink-common-mgmt.24.3.1.1.1 |
swPoEPortCtrlStateThe PoE port state. Enables or disables the PoE function on the specific port.
The default setting is enable.rw Enumeration .dlink-common-mgmt.24.3.1.1.2 |
swPoEPortCtrlPriorityThe PoE port priority. Port priority affects power-up order (after a
rest, the ports are powered up according to their priority) and shutdown
order (when exceeding the power budget, the ports are shut down according
to their priority if power_disconnect_method is set to deny_low_priority_port)
Default setting is low.rw Enumeration .dlink-common-mgmt.24.3.1.1.3 |
swPoEPortCtrlPowerLimitThere are 4 pre-defined values for users' convenience to set the upper
power limit for class 0, class 1, class 2, and class 3.
class_0: 15400mW (The maximum power provided by PSE (switch) is 12.95 W + power loss on cable)
class_1: 4000mW (The maximum power provided by PSE is 3.84 W + power loss on cable)
class_2: 7000mW (The maximum power provided by PSE is 6.49 W + power loss on cable)
class_3: 15400mW (The maximum power provided by PSE is 12.95 W + power loss on cable)
user-defined: User can select this setting and configure the range in swPoEPortCtrlUserDefined.rw Enumeration .dlink-common-mgmt.24.3.1.1.4 |
swPoEPortCtrlUserDefinedUser defined per-port power limit (in milliwatts). If a port exceeds 10% of its power
limit, the PoE system will shut down that port. The default setting is 15400 mW.
Note: This object is valid only while the swPoEPortCtrlPowerLimit object is configured as
user-defined.rw INTEGER .dlink-common-mgmt.24.3.1.1.5 |
swPoEPortCtrlTimeRangeNameSpecifies the time_range that applies to the port of the POE.If time range is configured,
power can only be supplied during the period specified by the time range.rw SnmpAdminString .dlink-common-mgmt.24.3.1.1.6 |
swPoEPortInfo OBJECT IDENTIFIER .dlink-common-mgmt.24.4 |
swPoEPortInfoTableA table that contains PoE information about every port in this stack.
If a device has N ports, then the 1
N+1
2N+1
...... SEQUENCE OF SwPoEPortInfoEntry .dlink-common-mgmt.24.4.1 |
swPoEPortInfoEntryA list of PoE information for each port of the device in this stack. SwPoEPortInfoEntry .dlink-common-mgmt.24.4.1.1 |
swPoEPortInfoPortIndexThis object indicates the devices' port number in this stack.
If a device has N ports, then the 1
N+1
2N+1
......ro INTEGER .dlink-common-mgmt.24.4.1.1.1 |
swPoEPortInfoClassThe power class of the PD according to 802.3af definitions:
class 0: PD power consumption is within 0.44-12.95 watts,
class 1: PD power consumption is within 0.44-3.84 watts,
class 2: PD power consumption is within 3.84-6.49 watts,
class 3: PD power consumption is within 6.49-12.95 watts,
class 4: is reserved for future use.ro INTEGER .dlink-common-mgmt.24.4.1.1.2 |
swPoEPortInfoPowerThe port power consumption (in milliwatts).ro INTEGER .dlink-common-mgmt.24.4.1.1.3 |
swPoEPortInfoVoltageThe port input line voltage (in decivolts).ro INTEGER .dlink-common-mgmt.24.4.1.1.4 |
swPoEPortInfoCurrentThe port current (calculated in milliamps).ro INTEGER .dlink-common-mgmt.24.4.1.1.5 |
swPoEPortInfoStatusThe string describes the PoE port current status.ro DisplayString .dlink-common-mgmt.24.4.1.1.6 |
swpoEPortInfoLedStatusThe LED display for PoE port status.
on (1): power is provided to the port on which a 802.3af-compliant
or legacy PD is connected,
off(2): no power is provided to the port where there aren't any errors,
error(3): some error happens on the port, like overload, underload,
short,...or power budget exceeded conditions.ro Enumeration .dlink-common-mgmt.24.4.1.1.7 |