PLAINTREE-SWITCH-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for PLAINTREE-SWITCH-MIB.
54
Objects
Active
Status
5
Dependencies
Imported Objects
Objects
54 total| Object Name |
|---|
vendor OBJECT IDENTIFIER .1.3.6.1.4.1.295 |
RFC1155-SMI Unknown .1.3.6.1.4.1.295 |
switchTouchedThis trap is generated when the IDENTIFY button on the switch is pressed.
The agent throttles the generation of consecutive switchTouched traps
so that there is at least a two second gap between them. TRAP-TYPE .1.3.6.1.4.1.295.0.9 |
switch OBJECT IDENTIFIER .1.3.6.1.4.1.295.3 |
switchHardware OBJECT IDENTIFIER .1.3.6.1.4.1.295.3.1 |
switchChassis OBJECT IDENTIFIER .1.3.6.1.4.1.295.3.1.1 |
switchPort OBJECT IDENTIFIER .1.3.6.1.4.1.295.3.1.2 |
switchEthernetPort OBJECT IDENTIFIER .1.3.6.1.4.1.295.3.1.2.1 |
switchWaveBusPort OBJECT IDENTIFIER .1.3.6.1.4.1.295.3.1.2.2 |
switchFddiPort OBJECT IDENTIFIER .1.3.6.1.4.1.295.3.1.2.3 |
switchSoftware OBJECT IDENTIFIER .1.3.6.1.4.1.295.3.2 |
switchInfo OBJECT IDENTIFIER .1.3.6.1.4.1.295.3.2.1 |
switchBasicTableBasic information about the switch SEQUENCE OF SwitchEntry .1.3.6.1.4.1.295.3.2.1.1 |
switchBasicEntryIdentification information about a particular port on the switch. SwitchEntry .1.3.6.1.4.1.295.3.2.1.1.1 |
switchProductCodeAn ASCII string giving the product code of the switch.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.295.3.2.1.1.1.1 |
switchSerialNumberAn ASCII string giving the switch serial number.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.295.3.2.1.1.1.2 |
switchPlaceOfManufactureA number identifying where the switch was built.ro Enumeration .1.3.6.1.4.1.295.3.2.1.1.1.3 |
switchDateOfManufactureAn ASCII string giving the date of manufacture of the switch.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.295.3.2.1.1.1.4 |
switchMacAddressThe IEEE 802 MAC address of the switch.ro MacAddress (SNMPv2-TC) .1.3.6.1.4.1.295.3.2.1.1.1.5 |
switchCodeVersionAn ASCII string giving the version number of the switch software.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.295.3.2.1.1.1.6 |
switchBpeEnabledSetting this variable to TRUE (1) causes the bridge protocol engine
to perform the Spanning Tree Protocol as defined in IEEE802.1d.
Setting this variable to FALSE (0) causes the BPE to stop performing
the Spanning Tree Protocol. The value of this variable when the
switch starts operating is 1.rw INTEGER .1.3.6.1.4.1.295.3.2.1.1.1.7 |
eraseSwitchSnmpConfigInfoSetting this variable to TRUE (1) causes the switch to erase its
SNMP configuration information both from memory and from permanent
store. The switch the requests new configuration information using
the BOOTP protocol. Setting this variable to any other value has
no effect. This variable will always return 0 when read.rw INTEGER .1.3.6.1.4.1.295.3.2.1.1.1.8 |
restoreSwitchDot1dDefaultsSetting this variable to TRUE (1) causes the BPE to restore the
default spanning tree values given in the IEEE 802.1d specification.
This resets all writeable Bridge MIB variables in the dot1dStp group
of the Bridge MIB. Setting the variable to any other value has no
effect. This variable will always return 0 when read.rw INTEGER .1.3.6.1.4.1.295.3.2.1.1.1.9 |
performSwitchResetSetting this variable to TRUE (1) causes the switch to perform a
cold restart. As a result of this action a coldRestart trap will
be sent. Setting this variable to any other value has no effect.
This variable will always return 0 when read.rw INTEGER .1.3.6.1.4.1.295.3.2.1.1.1.10 |
switchIdentPressedThis variable is TRUE (1) if the IDENTIFY button on the switch has
been pressed since the variable was last read.
After this variable has been read it will be set to 0.ro INTEGER .1.3.6.1.4.1.295.3.2.1.1.1.11 |
ageFilterDatabaseSetting this variable to FALSE (0) causes the switch to stop aging
out entries from its filter database. Setting this variable to
TRUE (1) causes the switch to age out filter database entries as
defined in IEEE 802.1D. This variable is set to 0 whenever
the Switch restarts.rw INTEGER .1.3.6.1.4.1.295.3.2.1.1.1.12 |
clearStatisticsSetting this variable to TRUE (1) clears the traffic statistics
accumulators in the switch. Setting this variable to any other
value has no effect. The variable always returns 0 when read.rw INTEGER .1.3.6.1.4.1.295.3.2.1.1.1.13 |
switchBasicIndexThis is a dummy variable which provides a meta-index for the
Basic Information Table. INTEGER .1.3.6.1.4.1.295.3.2.1.1.1.100 |
switchPortTableIdentification information about the ports on a switch. SEQUENCE OF SwitchPortEntry .1.3.6.1.4.1.295.3.2.1.2 |
switchPortEntryIdentification information about a particular port on the switch. SwitchPortEntry .1.3.6.1.4.1.295.3.2.1.2.1 |
switchPortIndexThe number of the port to which the management information applies.ro INTEGER .1.3.6.1.4.1.295.3.2.1.2.1.1 |
switchPortProductCodeAn ASCII string giving the product code of the card on which this
port is located.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.295.3.2.1.2.1.2 |
switchPortSerialNumberAn ASCII string giving the serial number of the card on which this
port is located.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.295.3.2.1.2.1.3 |
switchPortPlaceOfManufactureA number identifying where the card on which this port is located
was built.ro Enumeration .1.3.6.1.4.1.295.3.2.1.2.1.4 |
switchPortDateOfManufactureAn ASCII string giving the date of manufacture of the card on which
this port is located.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.295.3.2.1.2.1.5 |
switchPortStateAn ASCII string giving the port's operational state.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.295.3.2.1.2.1.6 |
switchPortHighSensitivityThis variable is only valid if the port is an Ethernet port.
If this variable is set to TRUE (1), the receiver of the Ethernet
NIC controlling the port is set to high sensitivity. If the
variable is set to 0, the port is set to normal sensitivity.
If the ports on both ends of the 10BaseT link are set to high
sensitivity, the maximum permissable length of the link is
increased from 100 meters to 120 meters.
Caution: a high sensitivity receiver may be overdriven by
transmitters closer than 100 meters.
This variable is 0 when the switch is powered up for the first
time. Changes to this variable are preserved across
system restarts.rw INTEGER .1.3.6.1.4.1.295.3.2.1.2.1.7 |
restoreFddiMibDefaultsThis variable is ony valid if the port is an FDDI station.
Setting this variable to TRUE (1) causes the agent to restore
the default MIB values given in the ANSI X3T9.5/84-49 Rev 7.2
specification. This resets all writable FDDI MIB variables.
Setting the variable to any other value has no effect.
This variable will always return 0 when read.rw INTEGER .1.3.6.1.4.1.295.3.2.1.2.1.8 |
translateAllEthertypesThis variable is only valid if the port is an FDDI port.
If this variable is set to TRUE (1), the Bridge Tunnel Encapsulation
Protocol will be applied to frames containing any Ethertypes, not
just the ones in the Selective Translation Table.
If this variable is set to FALSE (0), the protocol will only be applied
to Ethertypes in the translation table.rw INTEGER .1.3.6.1.4.1.295.3.2.1.2.1.9 |
switchPortTxFramesThis counter is incremented by one for each frame transmitted
to the network segment attached to the port.ro Counter .1.3.6.1.4.1.295.3.2.1.2.1.10 |
switchPortRxFramesThis counter is incremented by one for each valid frame received
from the network segment attached to the port.ro Counter .1.3.6.1.4.1.295.3.2.1.2.1.11 |
switchPortFcsErrorsThis counter is incremented by one for each received frame which failed
its FCS check.ro Counter .1.3.6.1.4.1.295.3.2.1.2.1.12 |
switchPortFilterDiscardsThe number of frames received on this port which have been discarded
due to the filtering action of the port's bridge circuit.ro Counter .1.3.6.1.4.1.295.3.2.1.2.1.13 |
switchPortDelayExceededDiscardsThe number of frames discarded by this port due to excessive transit
delay through the switch. It reports the same value as the object
dot1dBasePortDelayExceededDiscards in the Bridge MIB (RFC 1493).ro Counter .1.3.6.1.4.1.295.3.2.1.2.1.14 |
switchPortMtuExceededDiscardsThe number of frames discarded by this port due to excessive size.
It is the same value reported in the object
dot1dBasePortMtuExceededDiscards in the Bridge MIB (RFC 1493).ro Counter .1.3.6.1.4.1.295.3.2.1.2.1.15 |
switchSelectiveTranslationTableThe Selective Translation Table as defined in IEEE 802.1h. SEQUENCE OF TranslationTableEntry .1.3.6.1.4.1.295.3.2.1.3 |
translationTableEntryOne entry in the STT. TranslationTableEntry .1.3.6.1.4.1.295.3.2.1.3.1 |
translationTablePortIndexThe table index - the port number on which the STT resides.ro INTEGER .1.3.6.1.4.1.295.3.2.1.3.1.1 |
translationTableEthertype1The first Ethertype for which the Bridge Tunnel Encapsulation Protocol
should be used.rw INTEGER .1.3.6.1.4.1.295.3.2.1.3.1.2 |
translationTableEntryValid1If this variable is set to TRUE (1), the Bridge Tunnel Encapsulation
Protocol will be applied to frames containing the first Ethertype.
If this variable is set to FALSE (0), the protocol will not be applied
to the Ethertype.rw INTEGER .1.3.6.1.4.1.295.3.2.1.3.1.3 |
translationTableEthertype2The second Ethertype for which the Bridge Tunnel Encapsulation Protocol
should be used.rw INTEGER .1.3.6.1.4.1.295.3.2.1.3.1.4 |
translationTableEntryValid2If this variable is set to TRUE (1), the Bridge Tunnel Encapsulation
Protocol will be applied to frames containing the second Ethertype.
If this variable is set to FALSE (0), the protocol will not be applied
to the Ethertype.rw INTEGER .1.3.6.1.4.1.295.3.2.1.3.1.5 |
translationTableEthertype3The third Ethertype for which the Bridge Tunnel Encapsulation Protocol
should be used.rw INTEGER .1.3.6.1.4.1.295.3.2.1.3.1.6 |
translationTableEntryValid3If this variable is set to TRUE (1), the Bridge Tunnel Encapsulation
Protocol will be applied to frames containing the third Ethertype.
If this variable is set to FALSE (0), the protocol will not be applied
to the Ethertype.rw INTEGER .1.3.6.1.4.1.295.3.2.1.3.1.7 |