Home/Catalog/PETH-MIB

PETH-MIB

The MIB module for for managing Powered Devices (PD) or Power Source Equipment (PSE) working according to the IEEE 802.af Powere Ethernet (DTE Power via MDI) standard.
Main OID:
powerEthernetMIB.1.3.6.1.2.1.10.7.20
52
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

52 total
Object Name
powerEthernetMIBThe MIB module for for managing Powered Devices (PD) or Power Source Equipment (PSE) working according to the IEEE 802.af Powere Ethernet (DTE Power via MDI) standard.
MODULE-IDENTITY
.1.3.6.1.2.1.10.7.20
pethObjects
OBJECT IDENTIFIER
.1.3.6.1.2.1.10.7.20.1
pethPsePortTableA table of objects that display and control the power characteristics power Ethernet ports on a Power Source Entity (PSE) device. This group will be implemented in managed power Ethernet switches and mid-span devices.
SEQUENCE OF PethPsePortEntry
.1.3.6.1.2.1.10.7.20.1.1
pethPsePortEntryA set of objects that display and control the power characteristics of a power Ethernet PSE port.
PethPsePortEntry
.1.3.6.1.2.1.10.7.20.1.1.1
pethPsePortGroupIndexThis variable uniquely identifies the group containing the port to which power Ethernet PSE is connected. Group means a box in the stack, or a module in a rack. For non-modular devices the value 1 is recommended.
INTEGER
.1.3.6.1.2.1.10.7.20.1.1.1.1
pethPsePortIndexThis variable uniquely identifies the power Ethernet PSE port within group pethPseGroupIndex to which the power Ethernet PSE entry is connected.
INTEGER
.1.3.6.1.2.1.10.7.20.1.1.1.2
pethPsePortPowerEnableEnables power supply on this port. Setting this object at a value auto(1) enables power and detection mechanism for this port. Setting this object at a value off(2) disables power and detection mechanism for this port.rw
Enumeration
.1.3.6.1.2.1.10.7.20.1.1.1.3
pethPsePortPowerIdPairsControlDescribes the capability of controlling the power pairs functionality to switch pins for sourcing power.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.2.1.10.7.20.1.1.1.4
pethPsePortPowerIdPairsDescribes or controls the pairs in use. If the value of pethPsePortPowerIdpairsControl is true, thisobject is writable. A value of signal(1) menas that the signal pairs only are in use. A value of spare(2) means that the spare pairs only are in use. A value of both(3) means that both the signal and the spare pairs are in use.rw
Enumeration
.1.3.6.1.2.1.10.7.20.1.1.1.5
pethPsePortPowerDetectionStatusControls the power detection mechanism of the port. Setting the value auto(1) enables the power detection mechanism of the port. Setting the value off(2) disables the power detection mechanism of the port. Setting the value test(3) puts the port in a test mode forcing continuous discovery without applying power regardless of whether PD detected.rw
Enumeration
.1.3.6.1.2.1.10.7.20.1.1.1.6
pethPsePortDetectionOperStatusDescribes the operational status of the port detection. A value of deliveringPower(1) indicates that the port executed the detection algorithm, found a PD connection and is currently delivering power. A value of off(2) indicates that the port did not find a PD connection and is not in serching mode. A value of searching(3) indicates that the detection algorithm is in work, and did not detect a valid PD. No power is currently provided. A value of fault(4) indicates that a fault was detected on the port .ro
Enumeration
.1.3.6.1.2.1.10.7.20.1.1.1.7
pethPsePortPowerPriorityThis object controls the priority of the port from the point of view of a power management algorithm. The priority that is set by this variable could be used by a control mechanism that prevents over current situations by disconnecting first ports with lower power priority. Ports that connect devices critical to the operation of the network - like the E911 telephones ports - should be set to higher priority.rw
Enumeration
.1.3.6.1.2.1.10.7.20.1.1.1.8
pethPsePortDenyErrorThis object describes an error resulted from an action of the power management mechanism. The value lowPriority(2) indicates that the port was disabled by the power management system, in order to keep active higher priority ports.ro
Enumeration
.1.3.6.1.2.1.10.7.20.1.1.1.9
pethPsePortStatusDescribes a current port status related to the power generation The value underCurrent(2) indicates that the port current is below the minimal value. The value overCurrent(3) indicates that the port current exceeds the maximal value. The value both(4) indicates that both underCurrent and overCurrent status happend from the lase Clear.ro
Enumeration
.1.3.6.1.2.1.10.7.20.1.1.1.10
pethPsePortStatusClearSetting the value of this object to clear(1) clears the value of the pethPsePortStatus to none(1).rw
Enumeration
.1.3.6.1.2.1.10.7.20.1.1.1.11
pethPsePortTypeA manager will set the value of this variable to a value that indicates the type of the device that is connected to theport. This value can be the result of the mapping the address of the station connected to the port and of the value of the pethPdPortType of the respective PD port.rw
Enumeration
.1.3.6.1.2.1.10.7.20.1.1.1.12
pethPsePortPowerClassificationsClassification is a way to tag different terminals on the power over LAN network according to their power consumption. Devices such as IP telephones, WLAN access points and others, will be classified according to their power requirements. Class Usage Maximum Power 0 Default 0.5 - 15.0 W 1 Optional 0.5 - 4.0 W 2 Optional 4.0 - 7.0 W 3 Optional 7.0 - 15.0 W 4 Optional Future Use 5 Optional Future Usero
Enumeration
.1.3.6.1.2.1.10.7.20.1.1.1.13
pethPdPortTableA table of objects that display and control the power characteristics power Ethernet ports on a Powered Device(PD) device. This group will be implemented in managed powered and mid-span devices.
SEQUENCE OF PethPdPortEntry
.1.3.6.1.2.1.10.7.20.1.2
pethPdPortEntryA set of objects that display and control the power characteristics of a Powered Device port.
PethPdPortEntry
.1.3.6.1.2.1.10.7.20.1.2.1
pethPdPortIndexAn index value that uniquely identifies an interface to a PD device. The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex. The mapping between the ifIndex values and the numbering of the port on the device is an implementation issue.
INTEGER
.1.3.6.1.2.1.10.7.20.1.2.1.1
pethPdPortPowerPairsDescribes the pairs in use. A value of signal(1) menas that the signal pairs only are in use. A value of spare(2) means that the spare pairs only are in use. A value of both(3) means that both the signal and the spare pairs are inuse.ro
Enumeration
.1.3.6.1.2.1.10.7.20.1.2.1.2
pethPdPortDetectionOperStatusDescribes the operational status of the port detection. The value off(1) means that the port does not receive power and the detection algorithm might still be operating. The value receivingPower(2) means that the port is receiving power.ro
Enumeration
.1.3.6.1.2.1.10.7.20.1.2.1.3
pethPdPortTypeThe type of the device. A management application may read the value of this variable and use it for setting the corresponding value of pethPsePortType of the port that connects the device.ro
Enumeration
.1.3.6.1.2.1.10.7.20.1.2.1.4
pethMainPseObjects
OBJECT IDENTIFIER
.1.3.6.1.2.1.10.7.20.1.3
pethMainPseTableA table of objects that display and control the Main power on a PSE device.
SEQUENCE OF PethMainPseEntry
.1.3.6.1.2.1.10.7.20.1.3.1
pethMainPseEntryA set of objects that display and control the Main power of a PSE.
PethMainPseEntry
.1.3.6.1.2.1.10.7.20.1.3.1.1
pethMainPseGroupIndexThis variable uniquely identifies the group to which power Ethernet PSE is connected. Group means box in the stack, module in a rack. It is recommended that the value 1 be used for non-modular devices
INTEGER
.1.3.6.1.2.1.10.7.20.1.3.1.1.1
pethMainPsePowerThe nominal power of the PSE expressed in Watts.rw
Integer32
.1.3.6.1.2.1.10.7.20.1.3.1.1.2
pethMainPseOperStatusThe operational status of the main PSE.ro
Enumeration
.1.3.6.1.2.1.10.7.20.1.3.1.1.3
pethMainPseConsumptionPowerMeasured usage power expressed in Watts.ro
Gauge32
.1.3.6.1.2.1.10.7.20.1.3.1.1.4
pethMainPseBackupPresentThis value reflects the presence and status of a backup PSE .ro
Enumeration
.1.3.6.1.2.1.10.7.20.1.3.1.1.5
pethMainPseBackupActivatedThis variable reflects the activation status of the backup PSEro
Enumeration
.1.3.6.1.2.1.10.7.20.1.3.1.1.6
pethMainPseUsageThresholdThe usage threshold expressed in percents for comparing the measured power and initiating an alarm if the threshold is exceeded.rw
INTEGER
.1.3.6.1.2.1.10.7.20.1.3.1.1.7
pethTrapsControl
OBJECT IDENTIFIER
.1.3.6.1.2.1.10.7.20.1.4
pethTrapsControlTableA table of objects that display and control the Main power on a PSE device.
SEQUENCE OF PethTrapsControlEntry
.1.3.6.1.2.1.10.7.20.1.4.1
pethTrapsControlEntryA set of objects that control the Trap events.
PethTrapsControlEntry
.1.3.6.1.2.1.10.7.20.1.4.1.1
pethTrapsControlGroupIndexThis variable uniquely identifies the group. Group means box in the stack, or module in a rack. It is recommended that the value 1 is used for non-modular devices.
INTEGER
.1.3.6.1.2.1.10.7.20.1.4.1.1.1
pethTrapsControlEnableEnable Traps from Agentrw
Enumeration
.1.3.6.1.2.1.10.7.20.1.4.1.1.2
pethNotifications
OBJECT IDENTIFIER
.1.3.6.1.2.1.10.7.20.2
pethPsePortOnOffTrapThis trap indicate if Pse Port is delivering or not power to the PD.
NOTIFICATION-TYPE
.1.3.6.1.2.1.10.7.20.2.1
pethPsePortDenyTrapThis trap indicate Port Deny service.
NOTIFICATION-TYPE
.1.3.6.1.2.1.10.7.20.2.2
pethPsePortStatusTrapThis trap indicate Port Change Status.
NOTIFICATION-TYPE
.1.3.6.1.2.1.10.7.20.2.3
pethMainPseBackUpActivatedTrapThis trap indicates that BackUp PSE is Activated .
NOTIFICATION-TYPE
.1.3.6.1.2.1.10.7.20.2.4
pethMainPowerUsageTrapThis trap indicate PSE Threshold usage indication .
NOTIFICATION-TYPE
.1.3.6.1.2.1.10.7.20.2.5
pethConformance
OBJECT IDENTIFIER
.1.3.6.1.2.1.10.7.20.3
pethCompliances
OBJECT IDENTIFIER
.1.3.6.1.2.1.10.7.20.3.1
pethComplianceDescribes the requirements for conformance to the Power Ethernet MIB.
Unknown
.1.3.6.1.2.1.10.7.20.3.1.1
pethGroups
OBJECT IDENTIFIER
.1.3.6.1.2.1.10.7.20.3.2
pethPsePortGroupPSE Port Objects.
Unknown
.1.3.6.1.2.1.10.7.20.3.2.1
pethPdPortGroupPD Port Objects.
Unknown
.1.3.6.1.2.1.10.7.20.3.2.2
pethMainPseGroupMain PSE Objects.
Unknown
.1.3.6.1.2.1.10.7.20.3.2.3
pethTrapsControlGroupTrap Control Objects.
Unknown
.1.3.6.1.2.1.10.7.20.3.2.4
PETH-MIB - SNMP MIB Reference | MIBs Explorer