Home/Catalog/PDN-DS1CONFIG-MIB

PDN-DS1CONFIG-MIB

Detailed view of the defined objects, syntax rules, and hierarchical paths.

20
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

20 total
Object Name
ent-ds1
OBJECT IDENTIFIER
.pdn-interfaces.5
RFC1155-SMI
Unknown
.pdn-interfaces.5
devDS1Test
OBJECT IDENTIFIER
.pdn-interfaces.5.1
devDS1TestTableThe Paradyne DS1 Interface Test Table.
SEQUENCE OF DevDS1TestEntry
.pdn-interfaces.5.1.1
devDS1TestEntryAn entry in the Paradyne DS1 Interface Test Table.
DevDS1TestEntry
.pdn-interfaces.5.1.1.1
devDS1TestIfIndexThe index value which uniquely identifies the interface for which this entry contains information on interface tests. The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex from the Interfaces table of MIB II (RFC 1213).ro
INTEGER
.pdn-interfaces.5.1.1.1.1
devDS1TestTypeThe index value which uniquely identifies the test for which this entry contains information.ro
Enumeration
.pdn-interfaces.5.1.1.1.2
devDS1TestControlA control variable used to start and stop operator- initiated interface tests. Writing idle(1) to the test table entry terminates the specified test for the interface associated with the entry. Writing running(2) activates the specified test for the interface, if allowed (i.e., the test must be allowed for the interface and in combination with any other tests currently executing for the interface). The rules for executing tests for the product are specified in the product's Operator's Guide. This variable is read to determine the current status of the test for the interface. A value of running(2) indicates the test is currently in progress on the interface. A value of idle(1) indicates that the test is currently not active on the interface.rw
Enumeration
.pdn-interfaces.5.1.1.1.3
devDS1TestArgumentAny argument required by the test being executed.rw
DisplayString
.pdn-interfaces.5.1.1.1.4
devDS1MonResultTableThe Paradyne Device Monitor Test Pattern Result Table.
SEQUENCE OF DevDS1MonResultEntry
.pdn-interfaces.5.1.2
devDS1MonResultEntryAn entry in the Paradyne Device Monitor Test Pattern Result Table.
DevDS1MonResultEntry
.pdn-interfaces.5.1.2.1
devDS1MonResultIfIndexThe index value which uniquely identifies the interface for which this entry contains information on the result of the monitor test pattern request. The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex from the Interfaces table of MIB II (RFC 1213).ro
INTEGER
.pdn-interfaces.5.1.2.1.1
devDS1MonResultTestTypeThe index value which uniquely identifies the test for which this entry contains information.ro
Enumeration
.pdn-interfaces.5.1.2.1.2
devDS1MonResultCodeThis object contains a code for more specific information on the test pattern monitoring result. A value of none(1) indicates that no further information is available. inSyncNoBitErrors(2) notes that the monitor pattern test has synchronized on the pattern and has not detected any bit errors. inSyncWithBitErrors indicates that the monitor pattern test has synchronized on the pattern and has detected bit errors. A monitor pattern test that has not synchronized on the request pattern returns a value of notInSync(4).ro
Enumeration
.pdn-interfaces.5.1.2.1.3
devDS1MonResultErrorCountThe number of bit errors detected in the received monitoring test pattern. The error count is updated once every second. The error count does not increment during periods when the pattern is not synchronized, or once synchronization is lost. The maximum value of this object is 99,999. Writing any value to this object will reset it to zero.rw
Gauge
.pdn-interfaces.5.1.2.1.4
devDS1SendControlTableThe Paradyne Device Send Test Pattern Control Table.
SEQUENCE OF DevDS1SendControlEntry
.pdn-interfaces.5.1.3
devDS1SendControlEntryAn entry in the Paradyne Device Send Test Pattern Control Table.
DevDS1SendControlEntry
.pdn-interfaces.5.1.3.1
devDS1SendControlIfIndexThe index value which uniquely identifies the interface for which this entry contains information on the result of the monitor test pattern request. The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex from the Interfaces table of MIB II (RFC 1213).ro
INTEGER
.pdn-interfaces.5.1.3.1.1
devDS1SendControlInjectErrSetting this object to inject(2) will inject one error in the data pattern being sent. If no pattern is being sent, the agent will return BAD VALUE. Reading this value will always return noOp(1).rw
Enumeration
.pdn-interfaces.5.1.3.1.2
devDS1SendControlErrorCountThe number of bit errors injected into the test pattern being sent. The maximum value of this object is 99,999.ro
Gauge
.pdn-interfaces.5.1.3.1.3
PDN-DS1CONFIG-MIB - SNMP MIB Reference | MIBs Explorer