PDN-DS1CONFIG-MIB
Detailed view of the defined objects, syntax rules, and hierarchical paths.
20
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
20 total| Object Name |
|---|
ent-ds1 OBJECT IDENTIFIER .pdn-interfaces.5 |
RFC1155-SMI Unknown .pdn-interfaces.5 |
devDS1Test OBJECT IDENTIFIER .pdn-interfaces.5.1 |
devDS1TestTableThe Paradyne DS1 Interface Test Table. SEQUENCE OF DevDS1TestEntry .pdn-interfaces.5.1.1 |
devDS1TestEntryAn entry in the Paradyne DS1 Interface Test Table. DevDS1TestEntry .pdn-interfaces.5.1.1.1 |
devDS1TestIfIndexThe index value which uniquely identifies the
interface for which this entry contains information
on interface tests. The interface identified by a
particular value of this index is the same interface
as identified by the same value of ifIndex from the
Interfaces table of MIB II (RFC 1213).ro INTEGER .pdn-interfaces.5.1.1.1.1 |
devDS1TestTypeThe index value which uniquely identifies the test for
which this entry contains information.ro Enumeration .pdn-interfaces.5.1.1.1.2 |
devDS1TestControlA control variable used to start and stop operator-
initiated interface tests. Writing idle(1) to the
test table entry terminates the specified test
for the interface associated with the entry. Writing
running(2) activates the specified test for the interface,
if allowed (i.e., the test must be allowed for the
interface and in combination with any other tests currently
executing for the interface). The rules for executing
tests for the product are specified in the product's
Operator's Guide.
This variable is read to determine the current status of
the test for the interface. A value of running(2) indicates
the test is currently in progress on the interface. A value
of idle(1) indicates that the test is currently not active
on the interface.rw Enumeration .pdn-interfaces.5.1.1.1.3 |
devDS1TestArgumentAny argument required by the test being executed.rw DisplayString .pdn-interfaces.5.1.1.1.4 |
devDS1MonResultTableThe Paradyne Device Monitor Test Pattern Result Table. SEQUENCE OF DevDS1MonResultEntry .pdn-interfaces.5.1.2 |
devDS1MonResultEntryAn entry in the Paradyne Device Monitor Test
Pattern Result Table. DevDS1MonResultEntry .pdn-interfaces.5.1.2.1 |
devDS1MonResultIfIndexThe index value which uniquely identifies the
interface for which this entry contains information
on the result of the monitor test pattern request.
The interface identified by a particular value of this
index is the same interface as identified by the same
value of ifIndex from the Interfaces table of MIB II
(RFC 1213).ro INTEGER .pdn-interfaces.5.1.2.1.1 |
devDS1MonResultTestTypeThe index value which uniquely identifies the test for
which this entry contains information.ro Enumeration .pdn-interfaces.5.1.2.1.2 |
devDS1MonResultCodeThis object contains a code for more specific information
on the test pattern monitoring result. A value of none(1)
indicates that no further information is available.
inSyncNoBitErrors(2) notes that the monitor pattern test
has synchronized on the pattern and has not detected any
bit errors. inSyncWithBitErrors indicates that the monitor
pattern test has synchronized on the pattern and has detected
bit errors. A monitor pattern test that has not synchronized
on the request pattern returns a value of notInSync(4).ro Enumeration .pdn-interfaces.5.1.2.1.3 |
devDS1MonResultErrorCountThe number of bit errors detected in the received
monitoring test pattern. The error count is updated
once every second. The error count does not increment
during periods when the pattern is not synchronized, or
once synchronization is lost. The maximum value of this
object is 99,999.
Writing any value to this object will reset it to zero.rw Gauge .pdn-interfaces.5.1.2.1.4 |
devDS1SendControlTableThe Paradyne Device Send Test Pattern Control Table. SEQUENCE OF DevDS1SendControlEntry .pdn-interfaces.5.1.3 |
devDS1SendControlEntryAn entry in the Paradyne Device Send Test
Pattern Control Table. DevDS1SendControlEntry .pdn-interfaces.5.1.3.1 |
devDS1SendControlIfIndexThe index value which uniquely identifies the
interface for which this entry contains information
on the result of the monitor test pattern request.
The interface identified by a particular value of this
index is the same interface as identified by the same
value of ifIndex from the Interfaces table of MIB II
(RFC 1213).ro INTEGER .pdn-interfaces.5.1.3.1.1 |
devDS1SendControlInjectErrSetting this object to inject(2) will inject one error
in the data pattern being sent. If no pattern is being
sent, the agent will return BAD VALUE. Reading this
value will always return noOp(1).rw Enumeration .pdn-interfaces.5.1.3.1.2 |
devDS1SendControlErrorCountThe number of bit errors injected into the test pattern
being sent. The maximum value of this object is 99,999.ro Gauge .pdn-interfaces.5.1.3.1.3 |