PAD-OPT-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for PAD-OPT-MIB.
174
Objects
Active
Status
2
Dependencies
Imported Objects
Objects
174 total| Object Name |
|---|
codex OBJECT IDENTIFIER .1.3.6.1.4.1.449 |
RFC1155-SMI Unknown .1.3.6.1.4.1.449 |
cdxProductSpecific OBJECT IDENTIFIER .1.3.6.1.4.1.449.2 |
cdx6500 OBJECT IDENTIFIER .1.3.6.1.4.1.449.2.1 |
cdx6500Configuration OBJECT IDENTIFIER .1.3.6.1.4.1.449.2.1.2 |
cdx6500CfgProtocolGroup OBJECT IDENTIFIER .1.3.6.1.4.1.449.2.1.2.1 |
cdx6500PCTPortProtocolGroup OBJECT IDENTIFIER .1.3.6.1.4.1.449.2.1.2.1.1 |
cdx6500PPCTPadPortTableAll of the configuration parameters relevant
to the Pad Port table. SEQUENCE OF Cdx6500PPCTPadPortEntry .1.3.6.1.4.1.449.2.1.2.1.1.1 |
cdx6500PPCTPadPortEntryA row of Pad Port configuration parameters. Cdx6500PPCTPadPortEntry .1.3.6.1.4.1.449.2.1.2.1.1.1.1 |
cdx6500padpCfgPortNumSpecifies the number of the port that you are configuring.
This number also serves as an entry number for the port you
are about to configure.ro INTEGER .1.3.6.1.4.1.449.2.1.2.1.1.1.1.1 |
cdx6500padpCfgConnectionTypeSpecify the control signal handshake and clocking required
for a connection to be made to this port:
simp - simple, no control signals required.
dtr - dedicated, require the data terminal ready
signal (DTR).
dtrd - same as DTR, except data set ready (DSR) drops
between calls.
dtrp - same as DTR, except DSR/DCD/CTS are held low in
the idle state.
dimo - port handshakes with attached dial modem.
dimoa - same as DIMO except DSR never raised on incoming
call from modem.
dimob - same as DIMO except DSR follows DTR on incoming
call from modem.
emri - port emulates a dial modem with ring indicator (RI).
emdc - port emulates a dial modem with data carrier
detect (DCD).
emdcio - port emulates a dial modem with DCD for incoming
and outgoing calls.
newvalSimp - same functionality as 'simp', new enumeration
added for RFc1155 compatibility.rw Enumeration .1.3.6.1.4.1.449.2.1.2.1.1.1.1.2 |
cdx6500padpCfgPortControlSpecify any of the following port control options:
NONE - no option specified.
MB - raise Pin 22 when the port becomes disabled.rw DisplayString .1.3.6.1.4.1.449.2.1.2.1.1.1.1.3 |
cdx6500padpCfgPortSpeedThis is the speed of the port in bits per second (baud rate).
newvalSpeed110 : same as 'speed110', new enumeration added
for RFC1155 compliance.rw Enumeration .1.3.6.1.4.1.449.2.1.2.1.1.1.1.4 |
cdx6500padpCfgAutoBaudSeqThis is the type of sequence used for autospeed detection
on an autospeed port.
crOnly - autospeed on <CR>
crDotCr - autospeed on <CR>.<CR>
tymnet - autospeed on a
telenet - autospeed on <CR><CR> for 1200 baud or lower
autospeed on @<CR> for 2400 baud or higher
dotDotCr - autospeed on two or more dots followed by <CR>
spacePCr - autospeed on <space>P<CR>
newvalCrOnly - same functionality as 'crOnly', new enumeration
added for RFC1155 compatibility.rw Enumeration .1.3.6.1.4.1.449.2.1.2.1.1.1.1.5 |
cdx6500padpCfgDataBitsThis is the number of data bits per character the PAD
port expects when it transmits and receives data from
the attached device.rw INTEGER .1.3.6.1.4.1.449.2.1.2.1.1.1.1.6 |
cdx6500padpCfgParityThis is the parity the PAD port generates and expects when it
transmits and receives data from the attached device.
none - no parity
space - Space Parity
mark - Mark Parity
even - Even Parity
odd - Odd Parity
auto - Auto Parity ( 7 odd / 7 even / 7 ignore )
autoA - Auto Parity ( 7 odd / 7 even / 8 none ).
newvalNone - same functionality as 'none', new enumeration
added for RFC1155 compatibility.rw Enumeration .1.3.6.1.4.1.449.2.1.2.1.1.1.1.7 |
cdx6500padpCfgStopBitsThis is the number of stop bits that the PAD port
generates when it transmits data to the attached device.
This parameter has no effect on data that is received from
the attached device.
stopBit1 - 1 Stop Bit.
stopBit1p5 - 1.5 Stop Bits.
stopBit2 - 2 Stop Bits.
newvalStopBit1 - same functionality as 'stopBit1', new
enumeration added for RFC1155 compatibility.rw Enumeration .1.3.6.1.4.1.449.2.1.2.1.1.1.1.8 |
cdx6500padpCfgProfileNameThis is the name of the PAD profile table to be used by
this PAD port.rw DisplayString .1.3.6.1.4.1.449.2.1.2.1.1.1.1.9 |
cdx6500padpCfgCallControlThis parameter allows call control to be used as follows:
NONE - no option specified
AUTO - automatic calling
AUTC - automatic calling when carriage return received
PCUD - pass call user data to user profiled for no service
signals
IBAR - bar calls inbound from PAD user
OBAR - bar calls outbound to PAD user
MNEM - allow mnemonic calls only
EMNEM - allow extended mnemonic call (without DOT)
Any combination of above specified by summing
(e.g. AUTO+IBAR+. . .)
TMNEM - Call Mnemonic (max 16 alphanumeric characters)
which is not resolved in the local node.
This option cannot be summed with any of the above.rw DisplayString .1.3.6.1.4.1.449.2.1.2.1.1.1.1.10 |
cdx6500padpCfgTermControlSpecify options for the attached device:
NONE - no option specified.
PASS - require password entry to use this PAD facility.
LIM - limit X.28 access to CALL and CLR commands only.
CUG - check closed user group; otherwise, CUG passes
transparently.
LCPY - allow local copying to this PAD port.
7BIT - use 7 data bits for character processing.
NADD - prevent PAD port from receiving calling address
and FAC service signals.
X28 - automatically return from X.28 mode to PAD mode
after sending the X.28 commands.
CNUI - Centralized NUI verification.
CUGOA - check closed user group but allow outgoing access;
otherwise, CUG passes transparently.
BMSG - show the PAD Bulletin/Banner Message even if the PAD
Profile #6 is configured as 1 or 5.
ADDR - does not show the calling address
HENNIS - supports Hanil bank terminal.
FRCB - connect to a French Cartes Bancaires terminal
CUGIA - check closed user group but allow incoming access; otherwise,
CUG passes transparently.\r\n\
NO-NULL - If port speed is below or equal to 1200, null characters
won't be appended to LF.
BCUG-ON- Subscription to Bilateral Closed User Group facility enabled.
BCUGOA - Subscription to Bilateral Closed User Group with Outgoing Access
facility enabled.
BCUG-OFF-Subscription to Bilateral Closed User Group related facilities
disabled.
BCUG-ON, BCUGOA and BCUG-OFF options are mutually exclusive.
Any combination of above specified by summing
(e.g. PASS+LIM).rw DisplayString .1.3.6.1.4.1.449.2.1.2.1.1.1.1.11 |
cdx6500padpCfgPadPromptNumThis parameter specifies which entry in the PAD Prompt Table
is used as a PAD prompt.rw INTEGER .1.3.6.1.4.1.449.2.1.2.1.1.1.1.12 |
cdx6500padpCfgRemoteParamNumThis specifies which entry in the Remote PAD Parameters Table
is sent to a remote PAD to update its X.3 characteristics when
it connects to this port:
0 - no remote PAD update is performed.rw INTEGER .1.3.6.1.4.1.449.2.1.2.1.1.1.1.13 |
cdx6500padpCfgAutoCallMnemThis mnemonic name is used if this port is configured for
auto-calling.rw DisplayString .1.3.6.1.4.1.449.2.1.2.1.1.1.1.14 |
cdx6500padpCfgAutoCallTimeoutThis is the time interval in seconds between call attempts
when auto-calling.rw INTEGER .1.3.6.1.4.1.449.2.1.2.1.1.1.1.15 |
cdx6500padpCfgMaxAutoCallThis parameter is used to specify the number of times
that the PAD port will attempt to call, when auto-calling
is enabled. A value of zero, will allow unlimited attempts.rw INTEGER .1.3.6.1.4.1.449.2.1.2.1.1.1.1.16 |
cdx6500padpCfgSubAddressCalls addressed to this node and with this subaddress will
be routed to this port.rw DisplayString .1.3.6.1.4.1.449.2.1.2.1.1.1.1.17 |
cdx6500padpCfgGroupSubaddressThe group subaddress is shared by one or more ports.
Calls addressed to this node and with this subaddress
will be routed to a port within the group.ro DisplayString .1.3.6.1.4.1.449.2.1.2.1.1.1.1.18 |
cdx6500padpCfgCugMembershipThe port may be a member of up to 8 different Closed User
Groups (CUGs). Each CUG membership must be a two digit number
(except
( e.g. 12,34,56,09,02,03 ).
00-99 - CUG Membershiprw DisplayString .1.3.6.1.4.1.449.2.1.2.1.1.1.1.19 |
cdx6500padpCfgBillingRecordThis controls whether billing (accounting) records will
be created for calls on this port.
newvalOff : same functionality as 'off', new enumeration
added for RFC1155 compatibility.rw Enumeration .1.3.6.1.4.1.449.2.1.2.1.1.1.1.20 |
cdx6500padpCfgInviteToClrThis specifies the handling of Invitation to Clear packet
when received.
none - Do nothing.
clrwo - Clear Call without performing a EIA disconnect.
clrwd - Clear Call and perform a EIA disconnect.
newvalNone - same functionality as 'none', new enumeration
added for RFC1155 compatibility.rw Enumeration .1.3.6.1.4.1.449.2.1.2.1.1.1.1.21 |
cdx6500padpCfgCallAcceptTimeSpecifies the time (in seconds) that the user has to make a
successful call, after a call has been cleared, before being
automatically disconnected. A maximum of three call attempts
are permitted when the Call Accept Timer is enabled.
1-255 - Call Accept Timeout (in seconds)
0 - Disables the Call Accept Timer.rw INTEGER .1.3.6.1.4.1.449.2.1.2.1.1.1.1.22 |
cdx6500padpCfgProtectionLevelThis specifies the level of data or connection protection
which will be applied to calls to or from this port.
The actual level for a call will be negotiated to the
lesser of this level and the level configured for the other
end of the call.
none - No protection
cpOnly - Connection protection only
fullDcp - Full data and connection protection.
newvalNone - same functionality as 'none', new enumeration
added for RFC1155 compatibility.rw Enumeration .1.3.6.1.4.1.449.2.1.2.1.1.1.1.23 |
cdx6500padpCfgReconnectTimeoutThis specifies the number of seconds that DCP on the
originating side will wait between reconnection attempts.rw INTEGER .1.3.6.1.4.1.449.2.1.2.1.1.1.1.24 |
cdx6500padpCfgReconnectTriesThis specifies the number of times that DCP on the originating
side will attempt to reconnect before clearing the call. If 0
is entered, it will not attempt to reconnect.rw INTEGER .1.3.6.1.4.1.449.2.1.2.1.1.1.1.25 |
cdx6500padpCfgMaxRcvBufLengthThis specifies the number of characters received by the driver
before forwarding the packet. This parameter is configurable
only for PAD ports of CPU+ cards.
1 - 128 : Value stored in MRBLR.rw INTEGER .1.3.6.1.4.1.449.2.1.2.1.1.1.1.26 |
cdx6500padpCfgCommandLanguageThis specifies the language for PAD commands.
ccitt : X.28 CCITT.
dpn : DPN ITI.
nc : Not configured.rw Enumeration .1.3.6.1.4.1.449.2.1.2.1.1.1.1.27 |
cdx6500padpCfgNUIFacilityFormatThis parameter specifies the format of the NUI facility field.
odpn : Specifies the old DPN format.
ndpn : Specifies the new DPN format.
dpn1992 : 1992 NUI format.
nc : Not configured.rw Enumeration .1.3.6.1.4.1.449.2.1.2.1.1.1.1.28 |
cdx6500padpCfgNUIVerifyTimerSpecify the NUI verification timer in seconds.
The call is cleared when the timer expires.rw INTEGER .1.3.6.1.4.1.449.2.1.2.1.1.1.1.29 |
cdx6500padpCfgMaxNUIViolationsThe maximum number of successive NUI verification failures
that can be tolerated when making verification attempts
through a pad port.rw INTEGER .1.3.6.1.4.1.449.2.1.2.1.1.1.1.30 |
cdx6500padpCfgActionTypeNUIVThis specifies the course of action to be taken if the
NUI violations exceed the configured threshold count.
This parameter is effective only if the Port Control
parameter is set to CNUI.
none : No action is taken .
disc : Port is disconnected.
degr : Port is busied-out for one minute then re-enabled.
lock : Port is disabled. Operator intervention is required
to enable the port.
nc : Not configured.rw Enumeration .1.3.6.1.4.1.449.2.1.2.1.1.1.1.31 |
cdx6500padpCfgCalledDTEAddressCalled DTE Address for packets with Call Mnemonic.rw DisplayString .1.3.6.1.4.1.449.2.1.2.1.1.1.1.32 |
cdx6500padpCfgCallingDTEIdentCalling DTE Identifier for packets with Call Mnemonic.rw DisplayString .1.3.6.1.4.1.449.2.1.2.1.1.1.1.33 |
cdx6500padpCfgCallingDTEPasswdCalling DTE Password for packets with Call Mnemonic.rw DisplayString .1.3.6.1.4.1.449.2.1.2.1.1.1.1.34 |
cdx6500padpCfgX28ResetServiceThis is the name of the X.28 Reset Service Signals table
to be used by this PAD port.rw DisplayString .1.3.6.1.4.1.449.2.1.2.1.1.1.1.35 |
cdx6500padpCfgX28ClearServiceThis is the name of the X.28 Clear Service Signals table
to be used by this PAD port.rw DisplayString .1.3.6.1.4.1.449.2.1.2.1.1.1.1.36 |
cdx6500padpCfgMAXMNEMFailuresThe maximum number of successive Mnemonic Call failures
that can be tolerated when making a call to the remote
using the mnemonic. This parameter is effective only if
the Port Control parameter is set to MNEM.rw INTEGER .1.3.6.1.4.1.449.2.1.2.1.1.1.1.37 |
cdx6500padpCfgActionTypeMNEMFailThis specifies the course of action to be taken if the
Mnemonic exceed the configured threshold count. This
parameter is effective only if the Port Control parameter
is set to MNEM.
none : No action is taken
disc : Port is disconnected.
degr : Port is busied-out for one minute then it is re-enabled.
lock : Port is disabled. Operator intervention is required
to enable the port.
nc : Not configured.rw Enumeration .1.3.6.1.4.1.449.2.1.2.1.1.1.1.38 |
cdx6500padpCfgActiveLineMessageThe message to be printed when the line becomes active (DTR
goes high).rw DisplayString .1.3.6.1.4.1.449.2.1.2.1.1.1.1.39 |
cdx6500padpCfgDelayActiveLineWhen the line becomes active (DTR goes high), Active line
message is sent after configured time.
This delay is in seconds.rw INTEGER .1.3.6.1.4.1.449.2.1.2.1.1.1.1.40 |
cdx6500padpCfgInterCharTimerThe maximum time period allowed between received characters in a frame.
Specified in 50ms increments (i.e. 5 means 250ms).rw INTEGER .1.3.6.1.4.1.449.2.1.2.1.1.1.1.41 |
cdx6500padpCfgElectricalInterfaceTypeSpecify the Electrical Interface Type:
V.24 - V.24 Electrical Interface Type
V.35 - V.35 Electrical Interface Type
V.36 - V.36 Electrical Interface Type
X.21 - X.21 Electrical Interface Type
NONE - Electrically disabledrw Enumeration .1.3.6.1.4.1.449.2.1.2.1.1.1.1.42 |
cdx6500padpCfgV24ElectricalInterfaceOptionSpecify the Pin 22 option:
RI - V.24 uses Pin 22 for Ring Indicator output signal
TM - V.24 uses Pin 22 for Test Mode input signalrw Enumeration .1.3.6.1.4.1.449.2.1.2.1.1.1.1.43 |
cdx6500padpCfgHighSpeedElectricalInterfaceOptionSpecify the cable type:
NONE - V.35/V.36/X.21 DCE with straight through cable
XOVER - V.35/V.36/X.21 DCE with crossover adapter cablerw Enumeration .1.3.6.1.4.1.449.2.1.2.1.1.1.1.44 |
cdx6500CfgGeneralGroup OBJECT IDENTIFIER .1.3.6.1.4.1.449.2.1.2.2 |
cdx6500CfgPadPromptTableAll of the configuration parameters relevant
to the PAD Prompt table. SEQUENCE OF Cdx6500CfgPadPromptEntry .1.3.6.1.4.1.449.2.1.2.2.4 |
cdx6500CfgPadPromptEntryA row of Pad Prompt table parameters Cdx6500CfgPadPromptEntry .1.3.6.1.4.1.449.2.1.2.2.4.1 |
cdx6500padpromptEntryNumThis is not a configuration parameter. Instead, it
identifies the particular PAD Prompt Table entry being
configured by the other parameter in the record.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.4.1.1 |
cdx6500padpromptPromptTextEnter PAD prompt as an ASCII character string, terminated
by a carriage return. Use line feed (^j) to generate a new
line. The prompt can have up to 1023 characters.ro DisplayString .1.3.6.1.4.1.449.2.1.2.2.4.1.2 |
cdx6500CfgPadProfileTableAll of the configuration parameters relevant
to the Pad Profile table. SEQUENCE OF Cdx6500CfgPadProfileEntry .1.3.6.1.4.1.449.2.1.2.2.8 |
cdx6500CfgPadProfileEntryA row of Pad Profile configuration parameters Cdx6500CfgPadProfileEntry .1.3.6.1.4.1.449.2.1.2.2.8.1 |
cdx6500padprofProfileNumThis is not a configuration parameter. Instead, it
identifies the particular PAD Profile Table entry
being configured by the other parameters in the record.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.8.1.1 |
cdx6500padprofProfileNameReference name for this PAD profile. Individual parameter
prompt messages are prefixed with X.3 parameter number.
Numbers greater than 100 indicate proprietary extensions.ro DisplayString .1.3.6.1.4.1.449.2.1.2.2.8.1.2 |
cdx6500padprofPar1#1, enables PAD recall to command mode during a call:
0 - PAD recall disabled
1 - PAD recall character = DLE = <^P>
32-126 - decimal value of character used for PAD recallro INTEGER .1.3.6.1.4.1.449.2.1.2.2.8.1.3 |
cdx6500padprofPar2#2, controls echo:
0 - echo disabled
1 - echo enabled.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.8.1.4 |
cdx6500padprofPar3#3, selects the ASCII characters used for data forwarding:
0 - no data forwarding characters
1 - A-Z, a-z, 0-9
2 - CR
4 - ESC, BEL,ENQ, ACK
8 - DEL, CAN, DC2
16 - EOT, ETX
32 - HT, LF, VT, FF
64 - all characters in columns 0 and 1 of the ASCII table
not mentioned above
XXX - any combination of the above values.ro DisplayString .1.3.6.1.4.1.449.2.1.2.2.8.1.5 |
cdx6500padprofPar4#4, selects forwarding idle timer delay:
0 - idle timer disabled
1 to 255 - value of idle timer in 1/20 seconds.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.8.1.6 |
cdx6500padprofPar5#5, specifies whether the attached terminal is flow
controlled (restrained from sending data) by the PAD port
sending the XON, XOFF characters. Also called Data Restraint
Inbound (DRI) using in-band control:
0 - no control with XON, XOFF
1 - control inbound data from device
2 - control inbound data and PAD commands from device
For DRI control using V.24 connector control signals
(CTS and pin 14), use parameter #105.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.8.1.7 |
cdx6500padprofPar6#6, controls PAD service signal messages to the attached
device:
0 - no service signal is sent
1 - service signals, other than the prompt, are sent
4 - prompt service signal is sent
5 - all service signals are sent
9 - extended format service signals, other than prompt,
are sent
12 - extended format prompt service signal is sent
13 - all service signals are sent in extended format.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.8.1.8 |
cdx6500padprofPar7#7, selects the PAD mode of operation on receipt of a break
signal from the attached terminal:
0 - do nothing
1 - send Interrupt packet
2 - send Reset packet
4 - send Indication of Break packet
5 - send Interrupt packet and Indication of Break packet
8 - escape from data transfer state
21 - discard output, send Interrupt packet,
and send Indication of Break Packetro INTEGER .1.3.6.1.4.1.449.2.1.2.2.8.1.9 |
cdx6500padprofPar9#9, controls padding after carriage return (CR):
0 - no padding after CR.
1 to 255 - number of padding characters inserted after CR.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.8.1.10 |
cdx6500padprofPar10#10, controls line folding:
0 - no line folding.
1 to 255 - number of characters per line.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.8.1.11 |
cdx6500padprofPar12#12, specifies whether the PAD port is flow controlled
(restrained from sending data) by the attached terminal
sending the XON, XOFF characters. Also called Data Restraint
Outbound (DRO) using in-band control:
0 - no control with XON, XOFF
1 - allow flow control on outbound data and service signals
For DRO control using V.24 connector control signals
(CTS and pin 14), use parameter #105.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.8.1.12 |
cdx6500padprofPar13#13, controls line feed insertion after carriage return (CR)
in data transfer state:
0 - no line feed insertion
1 - after CR in data sent to attached device
2 - after CR in data from the attached device
4 - after echo of CR to attached device
X - any combination of the above values.ro DisplayString .1.3.6.1.4.1.449.2.1.2.2.8.1.13 |
cdx6500padprofPar14#14, controls padding after line feed in the data transfer
state:
0 - no padding after line feed
1 to 255 - number of padding characters inserted after
line feed.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.8.1.14 |
cdx6500padprofPar15#15, controls local editing in data transfer state:
0 - no editing
1 - allow editing (idle timer data forwarding must be
disabled, parameter #4 = 0)
Editing is limited to deleting single characters, deleting
the entered line and displaying the entered line.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.8.1.15 |
cdx6500padprofPar16#16, decimal value of ASCII character used to delete a
character if editing is enabled (parameter #15 = 1).ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.8.1.16 |
cdx6500padprofPar17#17, decimal value of ASCII character used to delete a line
if editing is enabled (parameter #15 = 1).ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.8.1.17 |
cdx6500padprofPar18#18, decimal value of ASCII character used to display a line
if editing is enabled (parameter #15 = 1).ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.8.1.18 |
cdx6500padprofPar19#19, specifies the type of character delete service signal
sent by PAD:
0 - no service signal
1 - printing terminals (PAD sends \\ for each delete
character received from terminal)
2 - display terminals (PAD sends <BS><SP><BS> for
each delete character received from terminal)
8,32-126 - specifies the ASCII character used as the
editing service signal.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.8.1.19 |
cdx6500padprofPar20#20, specifies the echo mask:
0 - no echo mask (all characters echoed)
1 - no echo of CR
2 - no echo of LF
4 - no echo of VT, HT, or FF
8 - no echo of BEL or BS
16 - no echo of ESC or ENQ
32 - no echo of ACK, NAK, STX, SOH, EOT, ETB, or ETX
64 - no echo of editing characters as designated by
parameters 16, 17 and 18
128 - no echo of all other characters in columns 0 and 1
of the ASCII table not mentioned above and character DEL
XXX - any combination of the above values.ro DisplayString .1.3.6.1.4.1.449.2.1.2.2.8.1.20 |
cdx6500padprofPar21#21, controls the parity treatment of characters received and
transmitted to the attached device.
0 - No parity checking or generation
1 - Parity checked on received characters
2 - Parity generated in transmitted characters
4 - Parity stripped from received characters
x - any combination of the above values.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.8.1.21 |
cdx6500padprofPar22#22, controls page wait:
0 - page wait disabled.
1 to 255 - number of line feed characters sent
by the PAD for the page wait function.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.8.1.22 |
cdx6500padprofPar100#100, specifies the ASCII character used to simulate break
for attached terminals that do not have a break key:
0 - no break character defined
1 to 127 - decimal value of the character used to simulate
break.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.8.1.23 |
cdx6500padprofPar101#101, specifies the ASCII character used to toggle echo
substitution of entered data. This function available only
if parameter #2 = 1:
0 - no echo substitution function
1 to 127 - decimal value of character to use to toggle
on and off the echo substitution.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.8.1.24 |
cdx6500padprofPar102#102, specifies the ASCII character used to echo all
characters entered by the attached device when echo
substitution is toggled on:
0 - no echo when echo substitution toggled on
1 to 127 - decimal value of character used as echo, if
echoing is enabled by parameter #2 and substitution
is enabled by parameter #101.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.8.1.25 |
cdx6500padprofPar103#103, specifies the ASCII character used for the XON
function:
0 to 255 - decimal value of the XON characterro INTEGER .1.3.6.1.4.1.449.2.1.2.2.8.1.26 |
cdx6500padprofPar104#104, specifies the ASCII character used for the XOFF
function:
0 to 255 - decimal value of the XOFF character.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.8.1.27 |
cdx6500padprofPar105#105, specifies whether both the PAD and the attached
terminal are flow controlled (restrained from sending data)
by the use of V.24 control signals, rather than XON, XOFF.
This type of control is called out-of-band flow control.
The control applies to data, commands and responses to and
from an attached device:
0 - none using connector control signals
1 - Data Restraint Outbound, attached device flow controls
PAD with connector pin 14
2 - Data Restraint Inbound, PAD flow controls attached device
with connector pin 5, CTS
X - any combination formed by summing (e.g. 1+2 or 3)
For DRO control using XON/XOFF, use parameters #5 and #12.ro DisplayString .1.3.6.1.4.1.449.2.1.2.2.8.1.28 |
cdx6500padprofPar106#106, specifies parity of data sent to the network by the PAD:
0 - transparent - pass data as received
1 - space
2 - mark
3 - even
4 - oddro INTEGER .1.3.6.1.4.1.449.2.1.2.2.8.1.29 |
cdx6500padprofPar107#107, is the elapsed time of no user data input after which
a call on the port will be cleared:
0 - timer disabled
1 to 255 - timer value in minutes.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.8.1.30 |
cdx6500padprofPar108#108, specifies the ASCII character used to disconnect a call:
0 - no character disconnects the call.
1 to 127 - decimal value of call disconnect character.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.8.1.31 |
cdx6500padprofPar109#109, specifies the number of padding characters inserted
in the data sent to the attached device after a form feed:
0 - no padding characters inserted.
1 to 255 - number of padding characters to insert after FF.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.8.1.32 |
cdx6500padprofPar110#110, Selects the data forwarding delay after ESC is detected
0 - timer disabled.
1 to 255 - timer value in 1/20 second.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.8.1.33 |
cdx6500padprofPar111#111, Controls how the pad handles the echo of data when echo,
parameter 2, is on.
0 - No Priority. Data is output and characters
are echoed as they arrive.
1 - Input Priority. PAD holds output until input from
terminal is finished.
2 - Output Priority. PAD will reecho input after output.
3 - Formatted Screen. PAD will echo one block of data
for each prompt sent from host.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.8.1.34 |
cdx6500padprofPar112#112, Setting this parameter causes the PAD port to
dynamically forward data packets, as bandwidth becomes
available on the network link. Settings for X.3 parameters
1,2,3,4,15,16,17,18,19,20,100,101, 102,106,108,110,111 and
13 value 2,3,6 or 7 are ignored if parameter 112 is set.
0 - Dynamic forwarding turned off.
1 - Dynamic forwarding turned on.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.8.1.35 |
cdx6500padprofPar113#113, Controls Hewlett-Packard flow control.
0 - No HP flow control.
1 - HP host enq/ack control.
2 - HP terminal enq/ack control.
3 - HP host xon/xoff control.
4 - HP terminal xon/xoff control.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.8.1.36 |
cdx6500padprofPar114#114, Selects PAD operational mode:
0 - Normal PAD.
1 - Transparent Polled Async Host PAD.
2 - Transparent Polled Async Remote PAD.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.8.1.37 |
cdx6500padprofPar115#115, Selects Data Forwarding Criteria for Polled Async
PADs:
0 - Normal.
1 - Short Timer.
2 - RTS Signal Drop.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.8.1.38 |
cdx6500padprofPar116#116, Selects forwarding Short Timer duration for Polled
Async PADs:
0 - Short Timer disabled.
1 to 255 - Duration of Short Timer in milliseconds.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.8.1.39 |
cdx6500padprofPar117#117, Selects EIA Signalling Action for Polled Async PADs:
0 - None.
1 - Raise DCD before transmission and drop DCD
after transmission.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.8.1.40 |
cdx6500padprofPar118#118, Setting this parameter causes a Polled Async PAD to
buffer complete async messages from the network before
transmitting them to the attached device.
0 - Disabled.
1 - Enabled.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.8.1.41 |
cdx6500padprofPar119#119, This parameter specifies the amount of time that
DCD is held high before data transmission to the attached
device begins. This parameter is used when EIA Signalling
Action (#117) is configured to 1.
0 - DCD to Data Timer disabled.
1 to 255 - Duration of DCD to Data Timer in milliseconds.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.8.1.42 |
cdx6500CfgRemotePadTableAll of the configuration parameters relevant
to the Remote Pad Paramter table. SEQUENCE OF Cdx6500CfgRemotePadEntry .1.3.6.1.4.1.449.2.1.2.2.9 |
cdx6500CfgRemotePadEntryA row of Remote Pad configuration parameters Cdx6500CfgRemotePadEntry .1.3.6.1.4.1.449.2.1.2.2.9.1 |
cdx6500remotepadEntryNumThis is not a configuration parameter. Instead, it
identifies the particular PAD Parameter Table entry
being configured by the other parameters in the record.
This value is referenced by the parameter Remote PAD
Parameter Number in the PAD Port Record.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.1 |
cdx6500remotepadParamNum1Reference number of X.3 parameter sent to remote PAD when
a connection is made to a PAD port in this node.
Standard parameters and function are:
1 - PAD recall character 12 - data restraint out
2 - echo on/off 13 - <LF> insertion after <CR>
3 - forwarding, character 14 - <LF> padding
4 - forwarding, timer 15 - editing
5 - data restraint in 16 - character delete
6 - service signals 17 - line delete
7 - break handling 18 - line display
8 - discard output 19 - editing type
9 - <CR> padding 20 - echo mask
10 - line folding 21 - parity treatment
11 - speed 22 - page waitro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.2 |
cdx6500remotepadParamVal1Corresponding value of referenced X.3 parameter sent to
remote PAD when connection is made. Valid range of parameter
value depends on parameter.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.3 |
cdx6500remotepadParamNum2Reference number of X.3 parameter sent to remote PAD when
a connection is made to a PAD port in this node. Standard
parameters and function are:
1 - PAD recall character 12 - data restraint out
2 - echo on/off 13 - <LF> insertion after <CR>
3 - forwarding, character 14 - <LF> padding
4 - forwarding, timer 15 - editing
5 - data restraint in 16 - character delete
6 - service signals 17 - line delete
7 - break handling 18 - line display
8 - discard output 19 - editing type
9 - <CR> padding 20 - echo mask
10 - line folding 21 - parity treatment
11 - speed 22 - page waitro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.4 |
cdx6500remotepadParamVal2Corresponding value of referenced X.3 parameter sent to
remote PAD when connection is made. Valid range of parameter
value depends on parameter.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.5 |
cdx6500remotepadParamNum3Reference number of X.3 parameter sent to remote PAD when
a connection is made to a PAD port in this node. Standard
parameters and function are:
1 - PAD recall character 12 - data restraint out
2 - echo on/off 13 - <LF> insertion after <CR>
3 - forwarding, character 14 - <LF> padding
4 - forwarding, timer 15 - editing
5 - data restraint in 16 - character delete
6 - service signals 17 - line delete
7 - break handling 18 - line display
8 - discard output 19 - editing type
9 - <CR> padding 20 - echo mask
10 - line folding 21 - parity treatment
11 - speed 22 - page waitro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.6 |
cdx6500remotepadParamVal3Corresponding value of referenced X.3 parameter sent to
remote PAD when connection is made. Valid range of parameter
value depends on parameter.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.7 |
cdx6500remotepadParamNum4Reference number of X.3 parameter sent to remote PAD when
a connection is made to a PAD port in this node. Standard
parameters and function are:
1 - PAD recall character 12 - data restraint out
2 - echo on/off 13 - <LF> insertion after <CR>
3 - forwarding, character 14 - <LF> padding
4 - forwarding, timer 15 - editing
5 - data restraint in 16 - character delete
6 - service signals 17 - line delete
7 - break handling 18 - line display
8 - discard output 19 - editing type
9 - <CR> padding 20 - echo mask
10 - line folding 21 - parity treatment
11 - speed 22 - page waitro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.8 |
cdx6500remotepadParamVal4Corresponding value of referenced X.3 parameter sent to
remote PAD when connection is made. Valid range of parameter
value depends on parameter.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.9 |
cdx6500remotepadParamNum5Reference number of X.3 parameter sent to remote PAD
when a connection is made to a PAD port in this node.
Standard parameters and function are:
1 - PAD recall character 12 - data restraint out
2 - echo on/off 13 - <LF> insertion after <CR>
3 - forwarding, character 14 - <LF> padding
4 - forwarding, timer 15 - editing
5 - data restraint in 16 - character delete
6 - service signals 17 - line delete
7 - break handling 18 - line display
8 - discard output 19 - editing type
9 - <CR> padding 20 - echo mask
10 - line folding 21 - parity treatment
11 - speed 22 - page waitro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.10 |
cdx6500remotepadParamVal5Corresponding value of referenced X.3 parameter sent to
remote PAD when connection is made. Valid range of parameter
value depends on parameter.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.11 |
cdx6500remotepadParamNum6Reference number of X.3 parameter sent to remote PAD
when a connection is made to a PAD port in this node.
Standard parameters and function are:
1 - PAD recall character 12 - data restraint out
2 - echo on/off 13 - <LF> insertion after <CR>
3 - forwarding, character 14 - <LF> padding
4 - forwarding, timer 15 - editing
5 - data restraint in 16 - character delete
6 - service signals 17 - line delete
7 - break handling 18 - line display
8 - discard output 19 - editing type
9 - <CR> padding 20 - echo mask
10 - line folding 21 - parity treatment
11 - speed 22 - page waitro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.12 |
cdx6500remotepadParamVal6Corresponding value of referenced X.3 parameter sent to
remote PAD when connection is made. Valid range of parameter
value depends on parameter.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.13 |
cdx6500remotepadParamNum7Reference number of X.3 parameter sent to remote PAD
when a connection is made to a PAD port in this node.
Standard parameters and function are:
1 - PAD recall character 12 - data restraint out
2 - echo on/off 13 - <LF> insertion after <CR>
3 - forwarding, character 14 - <LF> padding
4 - forwarding, timer 15 - editing
5 - data restraint in 16 - character delete
6 - service signals 17 - line delete
7 - break handling 18 - line display
8 - discard output 19 - editing type
9 - <CR> padding 20 - echo mask
10 - line folding 21 - parity treatment
11 - speed 22 - page waitro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.14 |
cdx6500remotepadParamVal7Corresponding value of referenced X.3 parameter sent to
remote PAD when connection is made. Valid range of parameter
value depends on parameter.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.15 |
cdx6500remotepadParamNum8Reference number of X.3 parameter sent to remote PAD
when a connection is made to a PAD port in this node.
Standard parameters and function are:
1 - PAD recall character 12 - data restraint out
2 - echo on/off 13 - <LF> insertion after <CR>
3 - forwarding, character 14 - <LF> padding
4 - forwarding, timer 15 - editing
5 - data restraint in 16 - character delete
6 - service signals 17 - line delete
7 - break handling 18 - line display
8 - discard output 19 - editing type
9 - <CR> padding 20 - echo mask
10 - line folding 21 - parity treatment
11 - speed 22 - page waitro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.16 |
cdx6500remotepadParamVal8Corresponding value of referenced X.3 parameter sent to
remote PAD when connection is made. Valid range of parameter
value depends on parameter.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.17 |
cdx6500remotepadParamNum9Reference number of X.3 parameter sent to remote PAD
when a connection is made to a PAD port in this node.
Standard parameters and function are:
1 - PAD recall character 12 - data restraint out
2 - echo on/off 13 - <LF> insertion after <CR>
3 - forwarding, character 14 - <LF> padding
4 - forwarding, timer 15 - editing
5 - data restraint in 16 - character delete
6 - service signals 17 - line delete
7 - break handling 18 - line display
8 - discard output 19 - editing type
9 - <CR> padding 20 - echo mask
10 - line folding 21 - parity treatment
11 - speed 22 - page waitro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.18 |
cdx6500remotepadParamVal9Corresponding value of referenced X.3 parameter sent to
remote PAD when connection is made. Valid range of parameter
value depends on parameter.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.19 |
cdx6500remotepadParamNum10Reference number of X.3 parameter sent to remote PAD
when a connection is made to a PAD port in this node.
Standard parameters and function are:
1 - PAD recall character 12 - data restraint out
2 - echo on/off 13 - <LF> insertion after <CR>
3 - forwarding, character 14 - <LF> padding
4 - forwarding, timer 15 - editing
5 - data restraint in 16 - character delete
6 - service signals 17 - line delete
7 - break handling 18 - line display
8 - discard output 19 - editing type
9 - <CR> padding 20 - echo mask
10 - line folding 21 - parity treatment
11 - speed 22 - page waitro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.20 |
cdx6500remotepadParamVal10Corresponding value of referenced X.3 parameter sent to
remote PAD when connection is made. Valid range of parameter
value depends on parameter.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.21 |
cdx6500remotepadParamNum11Reference number of X.3 parameter sent to remote PAD
when a connection is made to a PAD port in this node.
Standard parameters and function are:
1 - PAD recall character 12 - data restraint out
2 - echo on/off 13 - <LF> insertion after <CR>
3 - forwarding, character 14 - <LF> padding
4 - forwarding, timer 15 - editing
5 - data restraint in 16 - character delete
6 - service signals 17 - line delete
7 - break handling 18 - line display
8 - discard output 19 - editing type
9 - <CR> padding 20 - echo mask
10 - line folding 21 - parity treatment
11 - speed 22 - page waitro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.22 |
cdx6500remotepadParamVal11Corresponding value of referenced X.3 parameter sent to
remote PAD when connection is made. Valid range of parameter
value depends on parameter.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.23 |
cdx6500remotepadParamNum12Reference number of X.3 parameter sent to remote PAD
when a connection is made to a PAD port in this node.
Standard parameters and function are:
1 - PAD recall character 12 - data restraint out
2 - echo on/off 13 - <LF> insertion after <CR>
3 - forwarding, character 14 - <LF> padding
4 - forwarding, timer 15 - editing
5 - data restraint in 16 - character delete
6 - service signals 17 - line delete
7 - break handling 18 - line display
8 - discard output 19 - editing type
9 - <CR> padding 20 - echo mask
10 - line folding 21 - parity treatment
11 - speed 22 - page waitro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.24 |
cdx6500remotepadParamVal12Corresponding value of referenced X.3 parameter sent to
remote PAD when connection is made. Valid range of parameter
value depends on parameter.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.25 |
cdx6500remotepadParamNum13Reference number of X.3 parameter sent to remote PAD
when a connection is made to a PAD port in this node.
Standard parameters and function are:
1 - PAD recall character 12 - data restraint out
2 - echo on/off 13 - <LF> insertion after <CR>
3 - forwarding, character 14 - <LF> padding
4 - forwarding, timer 15 - editing
5 - data restraint in 16 - character delete
6 - service signals 17 - line delete
7 - break handling 18 - line display
8 - discard output 19 - editing type
9 - <CR> padding 20 - echo mask
10 - line folding 21 - parity treatment
11 - speed 22 - page waitro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.26 |
cdx6500remotepadParamVal13Corresponding value of referenced X.3 parameter sent to
remote PAD when connection is made. Valid range of parameter
value depends on parameter.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.27 |
cdx6500remotepadParamNum14Reference number of X.3 parameter sent to remote PAD
when a connection is made to a PAD port in this node.
Standard parameters and function are:
1 - PAD recall character 12 - data restraint out
2 - echo on/off 13 - <LF> insertion after <CR>
3 - forwarding, character 14 - <LF> padding
4 - forwarding, timer 15 - editing
5 - data restraint in 16 - character delete
6 - service signals 17 - line delete
7 - break handling 18 - line display
8 - discard output 19 - editing type
9 - <CR> padding 20 - echo mask
10 - line folding 21 - parity treatment
11 - speed 22 - page waitro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.28 |
cdx6500remotepadParamVal14Corresponding value of referenced X.3 parameter sent to
remote PAD when connection is made. Valid range of parameter
value depends on parameter.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.29 |
cdx6500remotepadParamNum15Reference number of X.3 parameter sent to remote PAD
when a connection is made to a PAD port in this node.
Standard parameters and function are:
1 - PAD recall character 12 - data restraint out
2 - echo on/off 13 - <LF> insertion after <CR>
3 - forwarding, character 14 - <LF> padding
4 - forwarding, timer 15 - editing
5 - data restraint in 16 - character delete
6 - service signals 17 - line delete
7 - break handling 18 - line display
8 - discard output 19 - editing type
9 - <CR> padding 20 - echo mask
10 - line folding 21 - parity treatment
11 - speed 22 - page waitro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.30 |
cdx6500remotepadParamVal15Corresponding value of referenced X.3 parameter sent to
remote PAD when connection is made. Valid range of parameter
value depends on parameter.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.31 |
cdx6500remotepadParamNum16Reference number of X.3 parameter sent to remote PAD
when a connection is made to a PAD port in this node.
Standard parameters and function are:
1 - PAD recall character 12 - data restraint out
2 - echo on/off 13 - <LF> insertion after <CR>
3 - forwarding, character 14 - <LF> padding
4 - forwarding, timer 15 - editing
5 - data restraint in 16 - character delete
6 - service signals 17 - line delete
7 - break handling 18 - line display
8 - discard output 19 - editing type
9 - <CR> padding 20 - echo mask
10 - line folding 21 - parity treatment
11 - speed 22 - page waitro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.32 |
cdx6500remotepadParamVal16Corresponding value of referenced X.3 parameter sent to
remote PAD when connection is made. Valid range of parameter
value depends on parameter.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.33 |
cdx6500remotepadParamNum17Reference number of X.3 parameter sent to remote PAD
when a connection is made to a PAD port in this node.
Standard parameters and function are:
1 - PAD recall character 12 - data restraint out
2 - echo on/off 13 - <LF> insertion after <CR>
3 - forwarding, character 14 - <LF> padding
4 - forwarding, timer 15 - editing
5 - data restraint in 16 - character delete
6 - service signals 17 - line delete
7 - break handling 18 - line display
8 - discard output 19 - editing type
9 - <CR> padding 20 - echo mask
10 - line folding 21 - parity treatment
11 - speed 22 - page waitro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.34 |
cdx6500remotepadParamVal17Corresponding value of referenced X.3 parameter sent to
remote PAD when connection is made. Valid range of parameter
value depends on parameter.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.35 |
cdx6500remotepadParamNum18Reference number of X.3 parameter sent to remote PAD
when a connection is made to a PAD port in this node.
Standard parameters and function are:
1 - PAD recall character 12 - data restraint out
2 - echo on/off 13 - <LF> insertion after <CR>
3 - forwarding, character 14 - <LF> padding
4 - forwarding, timer 15 - editing
5 - data restraint in 16 - character delete
6 - service signals 17 - line delete
7 - break handling 18 - line display
8 - discard output 19 - editing type
9 - <CR> padding 20 - echo mask
10 - line folding 21 - parity treatment
11 - speed 22 - page waitro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.36 |
cdx6500remotepadParamVal18Corresponding value of referenced X.3 parameter sent to
remote PAD when connection is made. Valid range of parameter
value depends on parameter.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.37 |
cdx6500remotepadParamNum19Reference number of X.3 parameter sent to remote PAD
when a connection is made to a PAD port in this node.
Standard parameters and function are:
1 - PAD recall character 12 - data restraint out
2 - echo on/off 13 - <LF> insertion after <CR>
3 - forwarding, character 14 - <LF> padding
4 - forwarding, timer 15 - editing
5 - data restraint in 16 - character delete
6 - service signals 17 - line delete
7 - break handling 18 - line display
8 - discard output 19 - editing type
9 - <CR> padding 20 - echo mask
10 - line folding 21 - parity treatment
11 - speed 22 - page waitro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.38 |
cdx6500remotepadParamVal19Corresponding value of referenced X.3 parameter sent to
remote PAD when connection is made. Valid range of parameter
value depends on parameter.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.39 |
cdx6500remotepadParamNum20Reference number of X.3 parameter sent to remote PAD
when a connection is made to a PAD port in this node.
Standard parameters and function are:
1 - PAD recall character 12 - data restraint out
2 - echo on/off 13 - <LF> insertion after <CR>
3 - forwarding, character 14 - <LF> padding
4 - forwarding, timer 15 - editing
5 - data restraint in 16 - character delete
6 - service signals 17 - line delete
7 - break handling 18 - line display
8 - discard output 19 - editing type
9 - <CR> padding 20 - echo mask
10 - line folding 21 - parity treatment
11 - speed 22 - page waitro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.40 |
cdx6500remotepadParamVal20Corresponding value of referenced X.3 parameter sent to
remote PAD when connection is made. Valid range of parameter
value depends on parameter.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.41 |
cdx6500remotepadParamNum21Reference number of X.3 parameter sent to remote PAD
when a connection is made to a PAD port in this node.
Standard parameters and function are:
1 - PAD recall character 12 - data restraint out
2 - echo on/off 13 - <LF> insertion after <CR>
3 - forwarding, character 14 - <LF> padding
4 - forwarding, timer 15 - editing
5 - data restraint in 16 - character delete
6 - service signals 17 - line delete
7 - break handling 18 - line display
8 - discard output 19 - editing type
9 - <CR> padding 20 - echo mask
10 - line folding 21 - parity treatment
11 - speed 22 - page waitro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.42 |
cdx6500remotepadParamVal21Corresponding value of referenced X.3 parameter sent to
remote PAD when connection is made. Valid range of parameter
value depends on parameter.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.43 |
cdx6500remotepadParamNum22Reference number of X.3 parameter sent to remote PAD
when a connection is made to a PAD port in this node.
Standard parameters and function are:
1 - PAD recall character 12 - data restraint out
2 - echo on/off 13 - <LF> insertion after <CR>
3 - forwarding, character 14 - <LF> padding
4 - forwarding, timer 15 - editing
5 - data restraint in 16 - character delete
6 - service signals 17 - line delete
7 - break handling 18 - line display
8 - discard output 19 - editing type
9 - <CR> padding 20 - echo mask
10 - line folding 21 - parity treatment
11 - speed 22 - page waitro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.44 |
cdx6500remotepadParamVal22Corresponding value of referenced X.3 parameter sent to
remote PAD when connection is made. Valid range of parameter
value depends on parameter.ro INTEGER .1.3.6.1.4.1.449.2.1.2.2.9.1.45 |
cdx6500Statistics OBJECT IDENTIFIER .1.3.6.1.4.1.449.2.1.3 |
cdx6500StatProtocolGroup OBJECT IDENTIFIER .1.3.6.1.4.1.449.2.1.3.1 |
cdx6500PSTPortProtocolGroup OBJECT IDENTIFIER .1.3.6.1.4.1.449.2.1.3.1.1 |
cdx6500PPSTPadPortTableAll of the statistics parameters relevant
to the Pad Port table. SEQUENCE OF Cdx6500PPSTPadPortEntry .1.3.6.1.4.1.449.2.1.3.1.1.1 |
cdx6500PPSTPadPortEntryA row of Pad Port statistics parameters. Cdx6500PPSTPadPortEntry .1.3.6.1.4.1.449.2.1.3.1.1.1.1 |
cdx6500padpStatPortNumNumber of the port.ro INTEGER .1.3.6.1.4.1.449.2.1.3.1.1.1.1.1 |
cdx6500padpStatPortStatusStatus of the port:
up - port is up and running.
busyout - port has been busied out.
disabled - port has been disabled.
newvalDisabled : same functionality 'disabled', new
new enumeration added RFC1155 compatibility.ro Enumeration .1.3.6.1.4.1.449.2.1.3.1.1.1.1.2 |
cdx6500padpStatUtilizationInPercentage of port bandwidth in use.ro INTEGER .1.3.6.1.4.1.449.2.1.3.1.1.1.1.3 |
cdx6500padpStatUtilizationOutPercentage of port bandwidth in use.ro INTEGER .1.3.6.1.4.1.449.2.1.3.1.1.1.1.4 |
cdx6500padpStatPortSpeedThe configured port speed.ro INTEGER .1.3.6.1.4.1.449.2.1.3.1.1.1.1.5 |
cdx6500padpStatCharInTotalSummary of the characters being received over the port.ro Counter .1.3.6.1.4.1.449.2.1.3.1.1.1.1.6 |
cdx6500padpStatCharOutTotalSummary of the characters being sent over the port.ro Counter .1.3.6.1.4.1.449.2.1.3.1.1.1.1.7 |
cdx6500padpStatCharsInPerSecSummary of the characters being received over the port.ro INTEGER .1.3.6.1.4.1.449.2.1.3.1.1.1.1.8 |
cdx6500padpStatCharsOutPerSecSummary of the characters being sent over the port.ro INTEGER .1.3.6.1.4.1.449.2.1.3.1.1.1.1.9 |
cdx6500padpStatPktInTotalSummary of the packets being sent over the port.ro Counter .1.3.6.1.4.1.449.2.1.3.1.1.1.1.10 |
cdx6500padpStatPktOutTotalSummary of the packets being sent over the port.ro Counter .1.3.6.1.4.1.449.2.1.3.1.1.1.1.11 |
cdx6500padpStatPktsInPerSecSummary of the packets being sent over the port.ro INTEGER .1.3.6.1.4.1.449.2.1.3.1.1.1.1.12 |
cdx6500padpStatPktsOutPerSecSummary of the packets being sent over the port.ro INTEGER .1.3.6.1.4.1.449.2.1.3.1.1.1.1.13 |
cdx6500padpStatPktsQueuedNumber of packets queued for output.ro INTEGER .1.3.6.1.4.1.449.2.1.3.1.1.1.1.14 |
cdx6500padpStatOverrunErrorsNumber of Overrun errors since the last reset.ro Counter16 .1.3.6.1.4.1.449.2.1.3.1.1.1.1.15 |
cdx6500padpStatParityErrorsNumber of Parity errors since the last reset.ro Counter16 .1.3.6.1.4.1.449.2.1.3.1.1.1.1.16 |
cdx6500padpStatFramingErrorsNumber of Framing errors since the last reset.ro Counter16 .1.3.6.1.4.1.449.2.1.3.1.1.1.1.17 |
cdx6500padpStatCurrentStatusStatus of the call on the specific port (Disconnect,
Calling, Called, Clearing, Connected, Local Copy)ro DisplayString .1.3.6.1.4.1.449.2.1.3.1.1.1.1.18 |
cdx6500padpStatPortStateCurrent port state:
x28 : The port is in Command mode.
pad : The port is in Data mode.
account : The port is waiting for the account name.
password : The port is waiting for the password.
newvalPad: same functionality as 'pad', new enumeration
added for RFC1155 compatibility.
na : Value not available.ro Enumeration .1.3.6.1.4.1.449.2.1.3.1.1.1.1.19 |
cdx6500Controls OBJECT IDENTIFIER .1.3.6.1.4.1.449.2.1.4 |