ONEFS-TRAP-MIB
The ONEFS-TRAP-MIB defines the SNMP trap definitions for NetApp's OneFS operating system, enabling the monitoring of cluster health events, node failures, file system state changes, and storage service anomalies.
Imported Objects
Objects
25 total| Object Name |
|---|
oneFSTrapsThis is the OneFS trap MIB MODULE-IDENTITY .1.3.6.1.4.1.12124.251 |
oneFSTrapByPriority OBJECT IDENTIFIER .1.3.6.1.4.1.12124.251.1 |
oneFSTrapCritThis notification is triggered everytime an emergency occurs on an appliance NOTIFICATION-TYPE .1.3.6.1.4.1.12124.251.1.1 |
oneFSTrapWarnThis notification is triggered everytime an alert occurs on an appliance NOTIFICATION-TYPE .1.3.6.1.4.1.12124.251.1.2 |
oneFSTrapInfoThis notification is triggered everytime a critical event occurs on an appliance NOTIFICATION-TYPE .1.3.6.1.4.1.12124.251.1.3 |
oneFSTrapEmrgThis notification is triggered everytime an emergency occurs on an appliance NOTIFICATION-TYPE .1.3.6.1.4.1.12124.251.1.4 |
oneFSTrapByFacility OBJECT IDENTIFIER .1.3.6.1.4.1.12124.251.2 |
oneFSTrapDefaultThis notification is triggered everytime a critical event occurs on an appliance NOTIFICATION-TYPE .1.3.6.1.4.1.12124.251.2.1 |
oneFSTrapNodeThis notification is triggered everytime a critical event occurs on an appliance NOTIFICATION-TYPE .1.3.6.1.4.1.12124.251.2.2 |
oneFSTrapWindowsNetworkingThis notification is triggered everytime a critical event occurs on an appliance NOTIFICATION-TYPE .1.3.6.1.4.1.12124.251.2.3 |
oneFSTrapProcessesThis notification is triggered everytime a critical event occurs on an appliance NOTIFICATION-TYPE .1.3.6.1.4.1.12124.251.2.4 |
oneFSTrapPowerThis notification is triggered everytime a critical event occurs on an appliance NOTIFICATION-TYPE .1.3.6.1.4.1.12124.251.2.5 |
oneFSTrapSpaceThis notification is triggered everytime a critical event occurs on an appliance NOTIFICATION-TYPE .1.3.6.1.4.1.12124.251.2.6 |
oneFSTrapRestripeThis notification is triggered everytime a critical event occurs on an appliance NOTIFICATION-TYPE .1.3.6.1.4.1.12124.251.2.7 |
oneFSTrapGeneralThis notification is triggered everytime a critical event occurs on an appliance NOTIFICATION-TYPE .1.3.6.1.4.1.12124.251.2.8 |
oneFSTrapNVRAMThis notification is triggered everytime a critical event occurs on an appliance NOTIFICATION-TYPE .1.3.6.1.4.1.12124.251.2.9 |
oneFSTrapTempThis notification is triggered everytime a critical event occurs on an appliance NOTIFICATION-TYPE .1.3.6.1.4.1.12124.251.2.10 |
oneFSTrapFanThis notification is triggered everytime a critical event occurs on an appliance NOTIFICATION-TYPE .1.3.6.1.4.1.12124.251.2.11 |
oneFSTrapFilesystemThis notification is triggered everytime a critical event occurs on an appliance NOTIFICATION-TYPE .1.3.6.1.4.1.12124.251.2.12 |
oneFSTrapDiskThis notification is triggered everytime a critical event occurs on an appliance NOTIFICATION-TYPE .1.3.6.1.4.1.12124.251.2.13 |
oneFSTrapCPUThis notification is triggered everytime a critical event occurs on an appliance NOTIFICATION-TYPE .1.3.6.1.4.1.12124.251.2.14 |
oneFSTrapTestThis notification is triggered everytime a critical event occurs on an appliance NOTIFICATION-TYPE .1.3.6.1.4.1.12124.251.2.15 |
oneFSTrapLicensingThis notification is triggered everytime a licensing event occurs on an appliance NOTIFICATION-TYPE .1.3.6.1.4.1.12124.251.2.16 |
oneFSTrapSnapshotsThis notification is triggered everytime a snapshots event occurs on an appliance NOTIFICATION-TYPE .1.3.6.1.4.1.12124.251.2.17 |
oneFSTrapSmartQuotasThis notification is triggered everytime a SmartQuotas event occurs on an appliance NOTIFICATION-TYPE .1.3.6.1.4.1.12124.251.2.18 |
More MIBs from Isilon
Browse all IsilonMIBs →The ISILON-TRAP-MIB defines SNMP trap definitions for the Dell EMC Isilon OneFS cluster operating system to asynchronously alert management systems on critical hardware failures, node state transitions, and file system events. These traps enable real-time monitoring of cluster health, including disk failures, network interface status changes, and service availability within the distributed storage environment.
SNMP MIB module
Standard SNMP MIB module defining data structures for OLD-CISCO-INTERFACES-MIB.
Standard SNMP MIB module defining data structures for OLD-CISCO-SYS-MIB.
The ONEFS-SNAPSHOT-MIB module enables monitoring of Isilon (Dell EMC) OneFS file system snapshot statistics, specifically tracking snapshot creation timestamps, retention durations, and storage consumption metrics for point-in-time data copies.
Standard SNMP MIB module defining data structures for OLD-CISCO-MEMORY-MIB.