ISILON-TRAP-MIB
AI MIB Summary
The ISILON-TRAP-MIB defines SNMP trap definitions for the Dell EMC Isilon OneFS cluster operating system to asynchronously alert management systems on critical hardware failures, node state transitions, and file system events. These traps enable real-time monitoring of cluster health, including disk failures, network interface status changes, and service availability within the distributed storage environment.
Traps for Isilon Systems OneFS operating system.
Main OID:
isilonTraps.1.3.6.1.4.1.12124.250
332
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
332 total| Object Name |
|---|
isilonTrapsTraps for Isilon Systems OneFS operating system. MODULE-IDENTITY .1.3.6.1.4.1.12124.250 |
groupStateTraps OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.10 |
nodeStatus OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.10.1 |
nodeStatusCritA critical node status event has occurred. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.10.1.3 |
nodeStatusInfoA node status event has occurred. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.10.1.7 |
nodeExpStatus OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.10.2 |
nodeExpStatusCritA disk-only node has gone offline and cannot be contacted by the cluster. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.10.2.3 |
nodeShutdown OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.10.3 |
nodeShutdownInfoA node is being shut down or rebooted. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.10.3.7 |
nodeShutdownFail OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.10.4 |
nodeShutdownFailCritShut down or reboot failed for a node. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.10.4.3 |
nodeRebootCoalesced OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.10.20 |
nodeRebootCoalescedInfoA node is being rebooted. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.10.20.7 |
nodeStatusCoalescing OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.10.21 |
nodeStatusCoalescingCritCritical node status events are occurring NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.10.21.3 |
nodeStatusCoalescingWarnWarning node status events are occurring NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.10.21.5 |
filesystemTraps OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.11 |
partitionUsage OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.11.1 |
partitionUsageCritA partition is over the critical threshold percentage. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.11.1.3 |
partitionUsageWarnA partition is over the warning threshold percentage. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.11.1.5 |
partitionUsageInfoA partition is over the info threshold percentage. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.11.1.7 |
clusterStorageUsage OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.11.2 |
clusterStorageUsageCritThe /ifs partition is near capacity. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.11.2.3 |
clusterStorageUsageWarnThe /ifs partition is near capacity. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.11.2.5 |
filesysError OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.11.3 |
filesysErrorCritA critical /ifs filesystem error has occurred NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.11.3.3 |
filesysErrorWarnA warning-level /ifs filesystem error has occurred NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.11.3.5 |
filesysErrorInfoAn /ifs filesystem error has occurred. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.11.3.7 |
diskPoolUsage OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.11.4 |
diskPoolUsageCritA disk pool is near capacity. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.11.4.3 |
diskPoolUsageWarnA disk pool is near capacity. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.11.4.5 |
diskPoolOldDbVersion OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.11.5 |
diskPoolOldDbVersionWarnThe SmartPools upgrade has not completed. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.11.5.5 |
ssdUsage OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.11.6 |
ssdUsageCritThe SSD drives are at capacity. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.11.6.1 |
ssdUsageWarnThe SSD drives are near capacity. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.11.6.2 |
ssdUsageInfoThe SSD drives are near capacity. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.11.6.3 |
filesysCoalesce OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.11.20 |
filesysCoalesceCritFilesystem issues are occurring at a critical level NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.11.20.3 |
filesysCoalesceWarnFilesystem issues are occurring at a warning level NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.11.20.5 |
smartQuotaTraps OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.12 |
quotaThreshError OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.12.1 |
quotaThreshErrorInfoSmartQuotas threshold violation NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.12.1.7 |
quotaNotifyError OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.12.2 |
quotaNotifyErrorWarnSmartQuotas threshold notification failed NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.12.2.5 |
quotaError OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.12.3 |
quotaErrorWarnSmartQuotas error NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.12.3.5 |
snapshotTraps OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.13 |
snapshotError OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.13.1 |
snapshotErrorWarnSnapshot error NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.13.1.5 |
snapshotReserve OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.13.2 |
snapshotReserveCritSnapshot reserve space is over its critical limit NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.13.2.3 |
snapshotReserveWarnSnapshot reserve space is over its warning limit NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.13.2.5 |
syncIQTraps OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.14 |
siqEvent OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.14.1 |
siqEventCritSyncIQ event NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.14.1.3 |
siqEventWarnSyncIQ event NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.14.1.5 |
siqError OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.14.2 |
siqErrorWarnSyncIQ error NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.14.2.5 |
siqPolicyCoalesced OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.14.20 |
siqPolicyCoalescedCritSyncIQ policy errors are occurring NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.14.20.3 |
siqPolicyCoalescedWarnSyncIQ policy errors are occurring NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.14.20.5 |
siqTargetCoalesced OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.14.21 |
siqTargetCoalescedCritSyncIQ errors are occurring for target NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.14.21.3 |
siqTargetCoalescedWarnSyncIQ errors are occurring for target NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.14.21.5 |
softwareTraps OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.15 |
jobEngineError OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.15.1 |
jobEngineErrorEmergThe cluster encountered one or more job failures. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.15.1.1 |
jobEngineErrorCritThe cluster encountered one or more job failures. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.15.1.3 |
jobEngineErrorWarnThe cluster encountered one or more job failures. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.15.1.5 |
jobEngineErrorInfoThe cluster encountered one or more job failures. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.15.1.7 |
flexProtectRunning OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.15.2 |
flexProtectRunningCritCluster is in need of restripe but FlexProtect is not running NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.15.2.3 |
flexProtectRunningWarnCluster is in need of restripe but FlexProtect is not running NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.15.2.5 |
flexProtectRunningInfoCluster is in need of restripe but FlexProtect is not running NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.15.2.7 |
avscanInfectedFile OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.15.3 |
avscanInfectedFileCritAVScan found an infected file NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.15.3.3 |
avscanInfectedFileWarnAVScan found an infected file NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.15.3.5 |
avscanInfectedFileInfoAVScan found an infected file NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.15.3.7 |
mcpProcFailed OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.15.5 |
mcpProcFailedWarnMCP reports a process has failed on a node NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.15.5.5 |
mcpProcKilled OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.15.6 |
mcpProcKilledWarnMCP killed a process on a node NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.15.6.5 |
licenseExpiration OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.15.7 |
licenseExpirationWarnOne or more licenses has expired NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.15.7.5 |
licenseExpirationInfoOne or more licenses is about to expire NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.15.7.7 |
firmwareUpdateIncomplete OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.15.8 |
firmwareUpdateIncompleteWarnA firmware update was not completely applied NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.15.8.5 |
testEvent OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.15.9 |
testEventCritTest event NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.15.9.3 |
nodeCPU OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.15.10 |
nodeCPUWarnA node has exceeded the Warning-level CPU utilization. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.15.10.5 |
nodeCPUInfoA node has exceeded the Info-level CPU utilization. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.15.10.7 |
mountdClientMountFailed OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.15.11 |
mountdClientMountFailedInfoMountd denied client mount request NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.15.11.7 |
mountdHostLookupFailed OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.15.12 |
mountdHostLookupFailedInfoMountd host lookup failed NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.15.12.7 |
mixedSedNonSedCluster OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.15.13 |
mixedSedNonSedClusterCritCluster contains a mix of encrypting nodes and non-encrypting nodes NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.15.13.3 |
nfsCookieTranslationFailed OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.15.15 |
nfsCookieTranslationFailedInfo64bit to 32bit cookie translation failed NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.15.15.1 |
avscanTraps OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.16 |
avscanNoServersConf OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.16.1 |
avscanNoServersConfCritNo ICAP servers configured for AVScan NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.16.1.3 |
avscanNoServersConfWarnNo ICAP servers configured for AVScan NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.16.1.5 |
avscanNoServersConfInfoNo ICAP servers configured for AVScan NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.16.1.7 |
avscanError OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.16.2 |
avscanErrorCritAVscan has encountered an error NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.16.2.3 |
avscanErrorWarnAVscan has encountered an error NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.16.2.5 |
avscanErrorInfoAVscan has encountered an error NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.16.2.7 |
avscanCoalesced OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.16.20 |
avscanCoalescedInfoAVScan is detecting problems NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.16.20.3 |
avscanCoalescedWarnAVScan is detecting problems NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.16.20.5 |
avscanCoalescedCritAVscan is detecting critical problems NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.16.20.7 |
netProtoTraps OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.17 |
clockSkew OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.17.1 |
clockSkewCritWindows ADS time skew outside limits. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.17.1.3 |
sharePermsUpgradeFail OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.17.2 |
sharePermsUpgradeFailCritWindows share permissions upgrade failed NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.17.2.3 |
winTimeConnectivityLost OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.17.3 |
winTimeConnectivityLostWarnConnectivity to the Windows Time server was lost NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.17.3.5 |
winNetMapFull OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.17.4 |
winNetMapFullCritWindows ID map range is full. Authentication may fail. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.17.4.3 |
winNetAuth OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.17.5 |
winNetAuthCritActive Directory connectivity failure NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.17.5.3 |
winNetAuthWarnActive Directory connectivity issue NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.17.5.5 |
lwioParam OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.17.6 |
lwioParamCritLWIO Parameter Invalid NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.17.6.3 |
winSmbUpgrade OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.17.7 |
winSmbUpgradeWarnWindows networking NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.17.7.2 |
winSmbUpgradeCritWindows networking NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.17.7.3 |
winNetworkCoalesce OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.17.20 |
winNetworkCoalesceCritThere are problems with Windows networking components NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.17.20.3 |
winNetworkCoalesceWarnThere are problems with Windows networking components NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.17.20.5 |
winIDmapCoalesce OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.17.21 |
winIDmapCoalesceCritThere are problems with the Windows ID map NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.17.21.3 |
winIDmapCoalesceWarnThere are problems with the Windows ID map NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.17.21.5 |
winAuthCoalesce OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.17.22 |
winAuthCoalesceCritThere are problems with Windows authentication components NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.17.22.3 |
winAuthCoalesceWarnThere are problems with Windows authentication components NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.17.22.5 |
winAuthUpgrade OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.17.23 |
winAuthUpgradeCritThere are problems with upgrading authentication components NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.17.23.3 |
networkingTraps OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.18 |
netStatus OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.18.1 |
netStatusCritA network interface is down NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.18.1.3 |
netStatusWarnA network interface is degraded or down NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.18.1.5 |
netStatusCoalescing OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.18.20 |
netStatusCoalescingCritCritical network problems are occurring NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.18.20.3 |
netStatusCoalescingWarnWarning network problems are occurring NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.18.20.5 |
hardwareTraps OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.19 |
hardwareError OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.19.1 |
hardwareErrorMsg OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.19.1.1 |
hardwareErrorMsgCritThere is a message concerning a hardware faliure NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.19.1.1.3 |
hardwareErrorMsgWarnThere is a message concerning a potential hardware faliure NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.19.1.1.5 |
hardwareErrorCritA critical hardware error has occurred. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.19.1.3 |
hardwareErrorWarnA node has a hardware error NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.19.1.5 |
hardwareErrorInfoA hardware problem is occurring. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.19.1.7 |
hwError OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.19.2 |
hwErrorCritPower Supply AC Failiure. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.19.2.3 |
diskNodeOffline OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.19.10 |
diskNodeOfflineCritThe expander is offline NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.19.10.3 |
hardwareCoalesced OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.19.20 |
hardwareCoalescedEmergThere are hardware issues on a node NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.19.20.1 |
hardwareCoalescedCritThere are hardware issues on a node NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.19.20.3 |
hardwareCoalescedWarnThere are hardware issues on a node NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.19.20.5 |
sensorCoalesced OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.19.50 |
sensorCoalescedEmergThere are sensor issues on a node NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.19.50.1 |
sensorCoalescedCritThere are sensor issues on a node NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.19.50.3 |
sensorCoalescedWarnThere are sensor issues on a node NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.19.50.5 |
fanCoalesced OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.19.51 |
fanCoalescedEmergThere are fan issues on a node NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.19.51.1 |
fanCoalescedCritThere are fan issues on a node NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.19.51.3 |
fanCoalescedWarnThere are fan issues on a node NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.19.51.5 |
tempCoalesced OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.19.52 |
tempCoalescedEmergThere are temp issues on a node NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.19.52.1 |
tempCoalescedCritThere are temp issues on a node NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.19.52.3 |
tempCoalescedWarnThere are temp issues on a node NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.19.52.5 |
voltsCoalesced OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.19.53 |
voltsCoalescedEmergThere are voltage issues on a node NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.19.53.1 |
voltsCoalescedCritThere are voltage issues on a node NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.19.53.3 |
voltsCoalescedWarnThere are voltage issues on a node NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.19.53.5 |
systemDiskTraps OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.20 |
driveStatus OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.20.1 |
driveStatusInfoA node has detected a problem with a drive NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.20.1.1 |
driveStatusCritA node has detected a problem with a drive NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.20.1.3 |
driveStatusWarnA node has detected a problem with a drive NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.20.1.5 |
bootDiskFail OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.20.2 |
bootDiskFailCritUnhealthy boot disks, mirror is degraded. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.20.2.3 |
bootDiskFailWarnUnhealthy boot disks, mirror is degraded. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.20.2.5 |
diskError OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.20.3 |
diskErrorWarnA node's disks are having problems NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.20.3.3 |
bootDiskMirrorReqMissing OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.20.4 |
bootdiskMirrorReqMissingCritError creating mirror on bootdisks. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.20.4.3 |
diskErrorCoalesced OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.20.20 |
diskErrorCoalescedCritA node's disks are having critical problems NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.20.20.3 |
diskErrorCoalescedWarnA node's disks are having warning level problems NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.20.20.5 |
sensorTraps OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.21 |
hwPwrSupply OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.21.1 |
hwPwrSupplyOver OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.21.1.1 |
hwPwrSupplyOverCritPower supply current over critical threshold NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.21.1.1.3 |
hwPwrSupplyOverWarnPower supply current over warning threshold NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.21.1.1.5 |
hwPwrSupplyUnder OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.21.1.2 |
hwPwrSupplyUnderCritPower supply current under critical threshold NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.21.1.2.3 |
hwPwrSupplyUnderWarnPower supply current under warning threshold NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.21.1.2.5 |
hwFan OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.21.2 |
hwFanOver OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.21.2.1 |
hwFanOverCritA node's fan is over critical threshold NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.21.2.1.3 |
hwFanOverWarnA node's fan is over warning threshold NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.21.2.1.5 |
hwFanOverInfoA node's fan is over warning threshold NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.21.2.1.7 |
hwFanUnder OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.21.2.2 |
hwFanUnderCritA node's fan is under critical threshold NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.21.2.2.3 |
hwFanUnderWarnA node's fan is under warning threshold NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.21.2.2.5 |
hwFanUnderInfoA node's fan is under warning threshold NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.21.2.2.7 |
hwFanCritA node's fan failed NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.21.2.3 |
hwFanWarnA node's fan monitor is about to fail NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.21.2.5 |
hwVoltage OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.21.10 |
hwVoltageOver OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.21.10.1 |
hwVoltageOverCritA node's voltage is over critical threshold NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.21.10.1.3 |
hwVoltageOverWarnA node's voltage is over warning threshold NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.21.10.1.5 |
hwVoltageOverInfoA node's voltage is over a threshold NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.21.10.1.7 |
hwVoltageUnder OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.21.10.2 |
hwVoltageUnderCritA node's voltage is under critical threshold NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.21.10.2.3 |
hwVoltageUnderWarnA node's voltage is under warning threshold NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.21.10.2.5 |
hwVoltageUnderInfoA node's voltage is under a threshold NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.21.10.2.7 |
hwTemp OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.21.11 |
hwTempOver OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.21.11.1 |
hwTempOverEmergA node's temperature is over emergency threshold NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.21.11.1.1 |
hwTempOverCritA node's temperature is over critical threshold NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.21.11.1.3 |
hwTempOverWarnA node's temperature is over warning threshold NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.21.11.1.5 |
hwTempOverInfoA node's temperature is over a threshold NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.21.11.1.7 |
hwTempUnder OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.21.11.2 |
hwTempUnderEmergA node's temperature is under emergency threshold NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.21.11.2.1 |
hwTempUnderCritA node's temperature is under critical threshold NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.21.11.2.3 |
hwTempUnderWarnA node's temperature is under warning threshold NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.21.11.2.5 |
hwTempUnderInfoA node's temperature is under a threshold NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.21.11.2.7 |
hwPower OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.21.12 |
hwPowerCritA node has a power supply problem NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.21.12.3 |
hwPowerWarnA node has a power supply monitoring problem NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.21.12.5 |
hwMem OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.21.13 |
hwMemCritA node is low on memory NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.21.13.3 |
hwCpuThrottle OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.21.14 |
hwCpuThrottleCritA node is at 100% CPU utilization NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.21.14.3 |
sensorMonitor OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.21.15 |
sensorMonitorCritA sensor failed NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.21.15.1 |
sensorMonitorWarnA sensor is failing NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.21.15.2 |
hwCurrent OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.21.16 |
hwCurrentOver OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.21.16.1 |
hwCurrentOverEmergA node's current is over emergency threshold NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.21.16.1.1 |
hwCurrentOverCritA node's current is over critical threshold NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.21.16.1.3 |
hwCurrentOverWarnA node's current is over warning threshold NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.21.16.1.5 |
hwCurrentOverInfoA node's current is over a threshold NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.21.16.1.7 |
hwCurrentUnder OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.21.16.2 |
hwCurrentUnderEmergA node's current is under emergency threshold NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.21.16.2.1 |
hwCurrentUnderCritA node's current is under critical threshold NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.21.16.2.3 |
hwCurrentUnderWarnA node's current is under warning threshold NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.21.16.2.5 |
hwCurrentUnderInfoA node's current is under a threshold NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.21.16.2.7 |
storageTransportTraps OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.22 |
sasPhyError OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.22.1 |
sasPhyErrorExpanderWarnA SAS PHY error was detected in the expander. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.22.1.5 |
sasPhyErrorControllerWarnA SAS PHY error was detected in the controller. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.22.1.7 |
storageTransportCoalesced OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.22.2 |
storageTransportCoalescedEmergThere are storage transport issues on a node NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.22.2.1 |
storageCoalescedCritThere are storage transport issues on a node NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.22.2.3 |
storageCoalescedWarnThere are storage transport issues on a node NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.22.2.5 |
cloudPoolsTraps OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.23 |
cloudpoolNetworkError OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.23.1 |
cloudpoolNetworkErrorCritCloudPools network issues NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.23.1.3 |
cloudpoolAuthenticationError OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.23.2 |
cloudpoolAuthenticationErrorCritCloudPools authentication issues NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.23.2.3 |
cloudpoolAuthorizationError OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.23.3 |
cloudpoolAuthorizationErrorCritCloudPools authorization issues NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.23.3.3 |
cloudpoolBucketNotFoundError OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.23.4 |
cloudpoolBucketNotFoundErrorCritCloudPools bucket not found issues NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.23.4.3 |
cloudpoolObjectNotFoundError OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.23.5 |
cloudpoolObjectNotFoundErrorCritCloudPools Object not found issues NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.23.5.3 |
cloudpoolDataCorruptionIntegrityError OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.23.6 |
cloudpoolDataCorruptionIntegrityErrorEmergCloudPools data corruption integrity emergency issues NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.23.6.1 |
cloudpoolNoUsableAccountFoundError OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.23.7 |
cloudpoolNoUsableAccountFoundErrorCritCloudPools no usable account found for the policy, cloudpool NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.23.7.3 |
cloudpoolCertificateError OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.23.8 |
cloudpoolCertificateErrorCritCloudPools Certificate issues NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.23.8.3 |
upgradeTraps OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.24 |
upgradeStart OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.24.1 |
upgradeStartInfoAn upgrade or rollback has been started. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.24.1.7 |
upgradeFinish OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.24.2 |
upgradeFinishInfoAn upgrade or rollback has finished. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.24.2.7 |
upgradeClusterEvent OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.24.3 |
upgradeClusterEventCritUpgrade cluster event. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.24.3.3 |
upgradeClusterEventWarnUpgrade cluster event. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.24.3.5 |
upgradeClusterEventInfoUpgrade cluster event. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.24.3.7 |
upgradeNodeEvent OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.24.4 |
upgradeNodeEventCritUpgrade node event. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.24.4.3 |
upgradeNodeEventWarnUpgrade node event. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.24.4.5 |
upgradeNodeEventInfoUpgrade node event. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.24.4.7 |
upgradeRollbackStart OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.24.5 |
upgradeRollbackStartInfoUpgrade rollback start. NOTIFICATION-TYPE .1.3.6.1.4.1.12124.250.24.5.7 |
variables OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.50 |
nodeIdentifierThe Logical Node Number of the node referenced in the notification.ro Integer32 .1.3.6.1.4.1.12124.250.50.1 |
measuredValueThe measured value that triggered the eventro Integer32 .1.3.6.1.4.1.12124.250.50.2 |
unitsThe units of the measurementro OCTET STRING .1.3.6.1.4.1.12124.250.50.3 |
oidThe OID of the sensor reporting a problemro OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.50.4 |
bayDrive bay numberro Integer32 .1.3.6.1.4.1.12124.250.50.5 |
ifNameInterface namero OCTET STRING .1.3.6.1.4.1.12124.250.50.6 |
phyPHY connectionro Integer32 .1.3.6.1.4.1.12124.250.50.7 |
errorMessageError messagero OCTET STRING .1.3.6.1.4.1.12124.250.50.8 |
errnoError numberro Integer32 .1.3.6.1.4.1.12124.250.50.9 |
stringArgA trap-related string argument.ro OCTET STRING .1.3.6.1.4.1.12124.250.50.10 |
messageA trap-related message string.ro OCTET STRING .1.3.6.1.4.1.12124.250.50.11 |
i64ArgError numberro Counter64 .1.3.6.1.4.1.12124.250.50.12 |
i32ArgInteger argumentro Integer32 .1.3.6.1.4.1.12124.250.50.13 |
measuredValueStrThe measured value that triggered the event represented as stringro OCTET STRING .1.3.6.1.4.1.12124.250.50.14 |
instanceIdentifierInstance ID of event generating the trapro OCTET STRING .1.3.6.1.4.1.12124.250.50.15 |
deviceIdentifierThe Device Node Number of the node referenced in the notification.ro Integer32 .1.3.6.1.4.1.12124.250.50.16 |
trapConformance OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.51 |
groupStateTrapsGroupCollection of traps for group state. Unknown .1.3.6.1.4.1.12124.250.51.1 |
filesystemTrapsGroupCollection of filesystem traps. Unknown .1.3.6.1.4.1.12124.250.51.11 |
smartQuotaTrapsGroupCollection of smartQuota traps. Unknown .1.3.6.1.4.1.12124.250.51.12 |
snapshotTrapsGroupCollection of snapshot traps. Unknown .1.3.6.1.4.1.12124.250.51.13 |
syncIQTrapsGroupCollection of syncIQ traps. Unknown .1.3.6.1.4.1.12124.250.51.14 |
softwareTrapsGroupCollection of software traps. Unknown .1.3.6.1.4.1.12124.250.51.15 |
avscanTrapsGroupCollection of avscan traps. Unknown .1.3.6.1.4.1.12124.250.51.16 |
netProtoTrapsGroupCollection of net protocol traps. Unknown .1.3.6.1.4.1.12124.250.51.17 |
networkingTrapsGroupCollection of networking traps. Unknown .1.3.6.1.4.1.12124.250.51.18 |
hardwareTrapsGroupCollection of sensor traps. Unknown .1.3.6.1.4.1.12124.250.51.19 |
systemDiskTrapsGroupCollection of system disk traps. Unknown .1.3.6.1.4.1.12124.250.51.20 |
sensorTrapsGroupCollection of sensor traps. Unknown .1.3.6.1.4.1.12124.250.51.21 |
storageTransportTrapsGroupCollection of storage transport traps. Unknown .1.3.6.1.4.1.12124.250.51.22 |
cloudPoolsTrapsGroupCollection of cloud pools traps. Unknown .1.3.6.1.4.1.12124.250.51.23 |
upgradeTrapsGroupCollection of upgrade traps. Unknown .1.3.6.1.4.1.12124.250.51.24 |
variablesGroupCollection of variable traps. Unknown .1.3.6.1.4.1.12124.250.51.50 |
trapCompliance OBJECT IDENTIFIER .1.3.6.1.4.1.12124.250.52 |
trapGroupComplianceCompliance statement for the Isilon traps. Unknown .1.3.6.1.4.1.12124.250.52.1 |