OCCAM-MLT-MIB
AI MIB Summary
The OCCAM-MLT-MIB module enables the monitoring and management of metallic line testing operations on customer access lines, specifically exposing diagnostic parameters such as line attenuation, noise margin, and signal-to-noise ratio (SNR) for DSL infrastructure. This MIB facilitates the retrieval of physical layer test results and status indicators required for troubleshooting copper-based subscriber loops.
This mib module describes objects used to perform Metallic Line Testing on customer access lines and to provide results.
Main OID:
occamMltMib.1.3.6.1.4.1.6066.2.1.1.3
109
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
109 total| Object Name |
|---|
occamMltMibThis mib module describes objects used to perform Metallic Line Testing on customer access lines and to provide results. MODULE-IDENTITY .1.3.6.1.4.1.6066.2.1.1.3 |
mltTestConfig OBJECT IDENTIFIER .1.3.6.1.4.1.6066.2.1.1.3.1 |
mltTestIdentifierSelects the mlt test to be run. Setting this value starts a test. This is a required parameter. Approximate expected test durations are as follows: statusSuite 1 second mltSuite 1 minute activeModeVoltages 3 seconds highImpedanceModeVoltages 9 seconds dcResistance 18 seconds capacitance 18 seconds loopDetect 9 seconds loopLength 9 seconds.rw MltTestIdentifier .1.3.6.1.4.1.6066.2.1.1.3.1.1 |
mltTestTypeSelects if a test is requested (only run if port is not in use) or forced. This is an optional parameter. If not specified, the request option is used.rw MltTestType .1.3.6.1.4.1.6066.2.1.1.3.1.2 |
mltTestPortSelects voice channel on which test will be run. This is a required parameter.rw Integer32 ( 1 .. 48 ) .1.3.6.1.4.1.6066.2.1.1.3.1.3 |
mltDcResistanceRangeSelects DC Resistance range value. This is an optional paramater. Default is 0 (auto mode).rw Integer32 ( 0 .. 3 ) .1.3.6.1.4.1.6066.2.1.1.3.1.4 |
mltLoopLengthMultiplierSelects loop length multiplier in nf. This is an optional parameter. If not specified an internal default value of 83nF/mile is used.rw Integer32 ( 10 .. 200 ) .1.3.6.1.4.1.6066.2.1.1.3.1.5 |
mltLoopDetectThresholdSelects the detection threshold in nF. This is an optional parameter. If not supplied, a loop detection threshold of 10nF is used.rw Integer32 ( 5 .. 200 ) .1.3.6.1.4.1.6066.2.1.1.3.1.6 |
mltTestStatus OBJECT IDENTIFIER .1.3.6.1.4.1.6066.2.1.1.3.2 |
mltLastTestStatusIndicates the status of the last run mlt test. Given that the various mlt tests take several seconds to 1 1/2 minutes to run, it is suggested that status polls be spaced 10-20 seconds apart. Additionally, a monitoring application could wait for the testComplete notification.ro MltTestStatus .1.3.6.1.4.1.6066.2.1.1.3.2.1 |
mltErrorTextIndicates the textual error in the case of an aborted test.ro OCTET STRING .1.3.6.1.4.1.6066.2.1.1.3.2.2 |
mltTestResults OBJECT IDENTIFIER .1.3.6.1.4.1.6066.2.1.1.3.3 |
mltStatusResultsTableThis table provides result of the status test suite. SEQUENCE OF MltStatusResultsEntry .1.3.6.1.4.1.6066.2.1.1.3.3.1 |
mltStatusResultsEntryEntry holding information about results of status suite tests. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured. MltStatusResultsEntry .1.3.6.1.4.1.6066.2.1.1.3.3.1.1 |
mltStatusAlarmIndicates GNK and/or OTEMP alarms active when status test was run.ro OCTET STRING .1.3.6.1.4.1.6066.2.1.1.3.3.1.1.1 |
mltStatusHookStateIndicates line hook state when status test was run.ro MltTestHookState .1.3.6.1.4.1.6066.2.1.1.3.3.1.1.2 |
mltStatusTransversalCurrentIndicates transversal current when status test was run.ro Integer32 UNITS "0.1 mA" .1.3.6.1.4.1.6066.2.1.1.3.3.1.1.3 |
mltStatusLongitudinalCurrentIndicates Longitudinal current when status test was run.ro Integer32 UNITS "0.1 mA" .1.3.6.1.4.1.6066.2.1.1.3.3.1.1.4 |
mltStatusTipVoltageIndicates tip voltage when status test was run.ro Integer32 UNITS "0.1 V" .1.3.6.1.4.1.6066.2.1.1.3.3.1.1.5 |
mltStatusRingVoltageIndicates ring voltage when status test was run.ro Integer32 UNITS "0.1 V" .1.3.6.1.4.1.6066.2.1.1.3.3.1.1.6 |
mltStatusTipRingVoltageIndicates tip-ring voltage when status test was run.ro Integer32 UNITS "0.1 V" .1.3.6.1.4.1.6066.2.1.1.3.3.1.1.7 |
mltStatusVddIndicates Vdd when status test was run.ro Integer32 UNITS "0.1 V" .1.3.6.1.4.1.6066.2.1.1.3.3.1.1.8 |
mltTestResultsTableThis table provides result of the mlt test suite. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured. Also, a resistance value of 9999 means that the result was greater than 1000 kOhms, but the exact value could not be measured. SEQUENCE OF MltTestResultsEntry .1.3.6.1.4.1.6066.2.1.1.3.3.2 |
mltTestResultsEntryEntry holding information about results of mlt suite tests. MltTestResultsEntry .1.3.6.1.4.1.6066.2.1.1.3.3.2.1 |
mltTestAlarmGNK and OTEMP bits set by the DuSLIC will be reported as alarms. GNK is typically cause by ground fault or foreign voltage condition. OTEMP is set when the DuSLIC is experiencing thermal overload. This parameter is non-intrusive.ro OCTET STRING .1.3.6.1.4.1.6066.2.1.1.3.3.2.1.1 |
mltTestHookStateHook state reflects the DuSLIC hook bit (offhook/onhook). This parameter is non-intrusive.ro MltTestHookState .1.3.6.1.4.1.6066.2.1.1.3.3.2.1.2 |
mltTestVddOn HDPOTS, internal Voltage VDD will be reported and compared to statistically derived thresholds. This parameter is intrusive during offhook but will be available during onhook.ro Integer32 UNITS "0.1 V" .1.3.6.1.4.1.6066.2.1.1.3.3.2.1.3 |
mltTestActiveModeVoltagesVdctrActive Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.ro Integer32 UNITS "0.1 Vdc" .1.3.6.1.4.1.6066.2.1.1.3.3.2.1.4 |
mltTestActiveModeVoltagesVdctgActive Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.ro Integer32 UNITS "0.1 Vdc" .1.3.6.1.4.1.6066.2.1.1.3.3.2.1.5 |
mltTestActiveModeVoltagesVdcrgActive Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.ro Integer32 UNITS "0.1 Vdc" .1.3.6.1.4.1.6066.2.1.1.3.3.2.1.6 |
mltTestActiveModeVoltagesVactrActive Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.ro Integer32 UNITS "0.1 Vrms" .1.3.6.1.4.1.6066.2.1.1.3.3.2.1.7 |
mltTestActiveModeVoltagesVactgActive Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.ro Integer32 UNITS "0.1 Vrms" .1.3.6.1.4.1.6066.2.1.1.3.3.2.1.8 |
mltTestActiveModeVoltagesVacrgActive Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.ro Integer32 UNITS "0.1 Vrms" .1.3.6.1.4.1.6066.2.1.1.3.3.2.1.9 |
mltTestHighImpedanceModeVoltagesVdctrHigh Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. DC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.ro Integer32 UNITS "0.1 Vdc" .1.3.6.1.4.1.6066.2.1.1.3.3.2.1.10 |
mltTestHighImpedanceModeVoltagesVdctgHigh Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. DC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.ro Integer32 UNITS "0.1 Vdc" .1.3.6.1.4.1.6066.2.1.1.3.3.2.1.11 |
mltTestHighImpedanceModeVoltagesVdcrgHigh Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. DC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.ro Integer32 UNITS "0.1 Vdc" .1.3.6.1.4.1.6066.2.1.1.3.3.2.1.12 |
mltTestHighImpedanceModeVoltagesVactrHigh Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. AC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.ro Integer32 UNITS "0.1 Vrms" .1.3.6.1.4.1.6066.2.1.1.3.3.2.1.13 |
mltTestHighImpedanceModeVoltagesVactgHigh Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. AC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.ro Integer32 UNITS "0.1 Vrms" .1.3.6.1.4.1.6066.2.1.1.3.3.2.1.14 |
mltTestHighImpedanceModeVoltagesVacrgHigh Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. AC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.ro Integer32 UNITS "0.1 Vrms" .1.3.6.1.4.1.6066.2.1.1.3.3.2.1.15 |
mltTestDcCurrentsItransversalFour DC currents will be reported: IT, IL, It and Ir. In normal condition, currents will be measured in active mode. These measurements will not be available if alarm is present.ro Integer32 UNITS "0.1 mA" .1.3.6.1.4.1.6066.2.1.1.3.3.2.1.16 |
mltTestDcCurrentsIlongitudinalFour DC currents will be reported: IT, IL, It and Ir. In normal condition, currents will be measured in active mode. These measurements will not be available if alarm is present.ro Integer32 UNITS "0.1 mA" .1.3.6.1.4.1.6066.2.1.1.3.3.2.1.17 |
mltTestDcCurrentsItipFour DC currents will be reported: IT, IL, It and Ir. In normal condition, currents will be measured in active mode. These measurements will not be available if alarm is present.ro Integer32 UNITS "0.1 mA" .1.3.6.1.4.1.6066.2.1.1.3.3.2.1.18 |
mltTestDcCurrentsIringFour DC currents will be reported: IT, IL, It and Ir. In normal condition, currents will be measured in active mode. These measurements will not be available if alarm is present.ro Integer32 UNITS "0.1 mA" .1.3.6.1.4.1.6066.2.1.1.3.3.2.1.19 |
mltTestCapacitanceCeqtrCapacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacitance will not be resolved. The equivalent capacitances CEQtr, CEQtg and CEQrg will be reported. They represent the following: CEQtr = Ctr + Ctg/4 + Crg/4 CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg) CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg) Capacitance measurements will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.ro Integer32 UNITS "nF" .1.3.6.1.4.1.6066.2.1.1.3.3.2.1.20 |
mltTestCapacitanceCeqtgCapacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacitance will not be resolved. The equivalent capacitances CEQtr, CEQtg and CEQrg will be reported. They represent the following: CEQtr = Ctr + Ctg/4 + Crg/4 CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg) CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg) Capacitance measurements will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.ro Integer32 UNITS "nF" .1.3.6.1.4.1.6066.2.1.1.3.3.2.1.21 |
mltTestCapacitanceCeqrgCapacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacitance will not be resolved. The equivalent capacitances CEQtr, CEQtg and CEQrg will be reported. They represent the following: CEQtr = Ctr + Ctg/4 + Crg/4 CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg) CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg) Capacitance measurements will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.ro Integer32 UNITS "nF" .1.3.6.1.4.1.6066.2.1.1.3.3.2.1.22 |
mltTestResistanceRtrDC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance ranges: (1) low, (2) medium, (3) high. If not specified, auto mode will be used. Resistance measurements will not be available if fuse test fails or alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state ` only.ro Integer32 UNITS "Ohm" .1.3.6.1.4.1.6066.2.1.1.3.3.2.1.23 |
mltTestResistanceRtgDC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance ranges: (1) low, (2) medium, (3) high. If not specified, auto mode will be used. Resistance measurements will not be available if fuse test fails or alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only.ro Integer32 UNITS "Ohm" .1.3.6.1.4.1.6066.2.1.1.3.3.2.1.24 |
mltTestResistanceRrgDC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance ranges: (1) low, (2) medium, (3) high. If not specified, auto mode will be used. Resistance measurements will not be available if fuse test fails or alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only.ro Integer32 UNITS "Ohm" .1.3.6.1.4.1.6066.2.1.1.3.3.2.1.25 |
mltTestGr909HazardousPotentialTestResultThis test fails if the T-G or R-G ac voltage is greater than 50 volts rms or the T-G or R-G dc voltage is greater than 135 volts. This test will report pass/fail. This test is intrusive and will be available in shutdown state only.ro MltTestPassFail .1.3.6.1.4.1.6066.2.1.1.3.3.2.1.26 |
mltTestGr909ForeignEmfTestResultThis test fails if the T-G or R-G ac voltage is greater than 50 volts rms or the T-G or R-G dc voltage is greater than 135 volts. This test will report pass/fail. This test is intrusive and will be available in shutdown state only.ro MltTestPassFail .1.3.6.1.4.1.6066.2.1.1.3.3.2.1.27 |
mltTestGr909FuseTestTipFuseThis test determines if these fuses are blown. This test will return pass/fail for tip and ring. This test will not be performed if alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only. This object is obsolete. Object name was changed.roobsolete MltTestPassFail .1.3.6.1.4.1.6066.2.1.1.3.3.2.1.28 |
mltTestGr909FuseTestRingFuseThis test determines if these fuses are blown. This test will return pass/fail for tip and ring. This test will not be performed if alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only. This object is obsolete. Object name was changed.roobsolete MltTestPassFail .1.3.6.1.4.1.6066.2.1.1.3.3.2.1.29 |
mltTestGr909ResistiveFaultTestResultThis test fails if the T-R, T-G or R-G dc resistance is less than 150k ohm. This test will not be performed if fuse test fails or alarm is present. This test will return pass/fail. This test is intrusive and will be available in shutdown state only.ro MltTestPassFail .1.3.6.1.4.1.6066.2.1.1.3.3.2.1.30 |
mltTestGr909ReceiverOffhookTestResultThis test fails if a non-linearity in the T-R dc resistance of greater than 15% when measured at two different voltage levels exists. This test will not be performed if fuse test fails or alarm is present. This test will return the DC resistances at two different operating points and the percent difference between the two DC resistances. This test is intrusive and will be available in shutdown state only.ro MltTestPassFail .1.3.6.1.4.1.6066.2.1.1.3.3.2.1.31 |
mltTestGr909ReceiverOffhookTestResistance1This test fails if a non-linearity in the T-R dc resistance of greater than 15% when measured at two different voltage levels exists. This test will not be performed if fuse test fails or alarm is present. This test will return the DC resistances at two different operating points and the percent difference between the two DC resistances. This test is intrusive and will be available in shutdown state only.ro Integer32 UNITS "Ohm" .1.3.6.1.4.1.6066.2.1.1.3.3.2.1.32 |
mltTestGr909ReceiverOffhookTestResistance2This test fails if a non-linearity in the T-R dc resistance of greater than 15% when measured at two different voltage levels exists. This test will not be performed if fuse test fails or alarm is present. This test will return the DC resistances at two different operating points and the percent difference between the two DC resistances. This test is intrusive and will be available in shutdown state only.ro Integer32 UNITS "Ohm" .1.3.6.1.4.1.6066.2.1.1.3.3.2.1.33 |
mltTestGr909ReceiverOffhookTestDifferenceThis test fails if a non-linearity in the T-R dc resistance of greater than 15% when measured at two different voltage levels exists. This test will not be performed if fuse test fails or alarm is present. This test will return the DC resistances at two different operating points and the percent difference between the two DC resistances. This test is intrusive and will be available in shutdown state only.ro Integer32 UNITS "%" .1.3.6.1.4.1.6066.2.1.1.3.3.2.1.34 |
mltTestGr909RingerTestResultThis test fails when the equivalent ringer count across tip and ring is less than 0.175 REN or greater than 5 REN. This test will not run if fuse test fails or alarm is present. This test will report passed/fail and the REN number. This parameter is intrusive and will be available in shutdown state shutdown only.ro MltTestRingerResult .1.3.6.1.4.1.6066.2.1.1.3.3.2.1.35 |
mltTestGr909RingerTestRenThis test fails when the equivalent ringer count across tip and ring is less than 0.175 REN or greater than 5 REN. This test will not run if fuse test fails or alarm is present. This test will report passed/fail and the REN number. This parameter is intrusive and will be available in shutdown state shutdown only.ro Integer32 UNITS "0.1 REN" .1.3.6.1.4.1.6066.2.1.1.3.3.2.1.36 |
mltTestErrorsIndicates GNK and/or OTEMP alarms active when test was run.ro OCTET STRING .1.3.6.1.4.1.6066.2.1.1.3.3.2.1.37 |
mltTestFuseTestTipFuseThis test determines if these fuses are blown. This test will return pass/fail for tip and ring. This test will not be performed if alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only.ro MltTestPassFail .1.3.6.1.4.1.6066.2.1.1.3.3.2.1.38 |
mltTestFuseTestRingFuseThis test determines if these fuses are blown. This test will return pass/fail for tip and ring. This test will not be performed if alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only.ro MltTestPassFail .1.3.6.1.4.1.6066.2.1.1.3.3.2.1.39 |
mltActiveModeVoltagesResultsTableThis table provides results of the mlt active mode voltages test. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured. SEQUENCE OF MltActiveModeVoltagesResultsEntry .1.3.6.1.4.1.6066.2.1.1.3.3.3 |
mltActiveModeVoltagesResultsEntryEntry holding information about results of mlt active mode voltages test. MltActiveModeVoltagesResultsEntry .1.3.6.1.4.1.6066.2.1.1.3.3.3.1 |
mltActiveModeVoltagesVdctrActive Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.ro Integer32 UNITS "0.1 Vdc" .1.3.6.1.4.1.6066.2.1.1.3.3.3.1.1 |
mltActiveModeVoltagesVdctgActive Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.ro Integer32 UNITS "0.1 Vdc" .1.3.6.1.4.1.6066.2.1.1.3.3.3.1.2 |
mltActiveModeVoltagesVdcrgActive Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.ro Integer32 UNITS "0.1 Vdc" .1.3.6.1.4.1.6066.2.1.1.3.3.3.1.3 |
mltActiveModeVoltagesVactrActive Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.ro Integer32 UNITS "0.1 Vrms" .1.3.6.1.4.1.6066.2.1.1.3.3.3.1.4 |
mltActiveModeVoltagesVactgActive Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.ro Integer32 UNITS "0.1 Vrms" .1.3.6.1.4.1.6066.2.1.1.3.3.3.1.5 |
mltActiveModeVoltagesVacrgActive Mode Tip/Ring AC Voltages: In active mode, the DuSLIC drives the tip/ring in a normal no shutdown state. Thus, VT and VR measurements should be 0 volt. AC voltages for T-R, T-G and R-G will be reported. Active mode measurements will not be available when alarm is detected. This parameter is intrusive and will be available in shutdown state only.ro Integer32 UNITS "0.1 Vrms" .1.3.6.1.4.1.6066.2.1.1.3.3.3.1.6 |
mltActiveModeVoltagesErrorsIndicates GNK and/or OTEMP alarms active when test was run.ro OCTET STRING .1.3.6.1.4.1.6066.2.1.1.3.3.3.1.7 |
mltHighImpedanceModeVoltagesResultsTableThis table provides result of the mlt test suite. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured. SEQUENCE OF MltHighImpedanceModeVoltagesResultsEntry .1.3.6.1.4.1.6066.2.1.1.3.3.4 |
mltHighImpedanceModeVoltagesResultsEntryEntry holding information about results of mlt high impedance mode voltages test. MltHighImpedanceModeVoltagesResultsEntry .1.3.6.1.4.1.6066.2.1.1.3.3.4.1 |
mltHighImpedanceModeVoltagesVdctrHigh Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. DC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.ro Integer32 UNITS "0.1 Vdc" .1.3.6.1.4.1.6066.2.1.1.3.3.4.1.1 |
mltHighImpedanceModeVoltagesVdctgHigh Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. DC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.ro Integer32 UNITS "0.1 Vdc" .1.3.6.1.4.1.6066.2.1.1.3.3.4.1.2 |
mltHighImpedanceModeVoltagesVdcrgHigh Impedance Mode Tip/Ring DC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. DC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.ro Integer32 UNITS "0.1 Vdc" .1.3.6.1.4.1.6066.2.1.1.3.3.4.1.3 |
mltHighImpedanceModeVoltagesVactrHigh Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. AC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.ro Integer32 UNITS "0.1 Vrms" .1.3.6.1.4.1.6066.2.1.1.3.3.4.1.4 |
mltHighImpedanceModeVoltagesVactgHigh Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. AC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.ro Integer32 UNITS "0.1 Vrms" .1.3.6.1.4.1.6066.2.1.1.3.3.4.1.5 |
mltHighImpedanceModeVoltagesVacrgHigh Impedance Mode Tip/Ring AC Voltages (Foreign Voltages): In this mode, the DuSLIC tip and ring are in high impedance. The measured voltages represent foreign voltages. AC voltages for T-R, T-G and R-G will be reported. This parameter is intrusive and will be available in shutdown state only.ro Integer32 UNITS "0.1 Vrms" .1.3.6.1.4.1.6066.2.1.1.3.3.4.1.6 |
mltHighImpedanceModeVoltagesErrorsIndicates GNK and/or OTEMP alarms active when test was run.ro OCTET STRING .1.3.6.1.4.1.6066.2.1.1.3.3.4.1.7 |
mltDcResistanceResultsTableThis table provides result of the DC resistance test. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured. Also, a resistance value of 9999 means that the result was greater than 1000 kOhms, but the exact value could not be measured. SEQUENCE OF MltDcResistanceResultsEntry .1.3.6.1.4.1.6066.2.1.1.3.3.5 |
mltDcResistanceResultsEntryEntry holding information about results of mlt DC resistance test. MltDcResistanceResultsEntry .1.3.6.1.4.1.6066.2.1.1.3.3.5.1 |
mltDcResistanceRtrDC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance ranges: (1) low, (2) medium, (3) high. If not specified, auto mode will be used. Resistance measurements will not be available if fuse test fails or alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only.ro Integer32 UNITS "Ohm" .1.3.6.1.4.1.6066.2.1.1.3.3.5.1.1 |
mltDcResistanceRtgDC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance ranges: (1) low, (2) medium, (3) high. If not specified, auto mode will be used. Resistance measurements will not be available if fuse test fails or alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only.ro Integer32 UNITS "Ohm" .1.3.6.1.4.1.6066.2.1.1.3.3.5.1.2 |
mltDcResistanceRrgDC resistance measurements will be based on a 3 terminal circuit model. Rtr, Rtg and Rrg will be provided. User will have the option of specifying 3 resistance ranges: (1) low, (2) medium, (3) high. If not specified, auto mode will be used. Resistance measurements will not be available if fuse test fails or alarm is present. This parameter is intrusive. This test is intrusive and will be available in shutdown state only.ro Integer32 UNITS "Ohm" .1.3.6.1.4.1.6066.2.1.1.3.3.5.1.3 |
mltDcResistanceErrorsIndicates GNK and/or OTEMP alarms active when test was run.ro OCTET STRING .1.3.6.1.4.1.6066.2.1.1.3.3.5.1.4 |
mltCapacitanceResultsTableThis table provides result of the mlt test suite. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured. SEQUENCE OF MltCapacitanceResultsEntry .1.3.6.1.4.1.6066.2.1.1.3.3.6 |
mltCapacitanceResultsEntryEntry holding information about results of mlt capacitance test. MltCapacitanceResultsEntry .1.3.6.1.4.1.6066.2.1.1.3.3.6.1 |
mltCapacitanceCeqtrCapacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacitance will not be resolved. The equivalent capacitances CEQtr, CEQtg and CEQrg will be reported. They represent the following: CEQtr = Ctr + Ctg/4 + Crg/4 CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg) CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg) Capacitance measurements will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.ro Integer32 UNITS "nF" .1.3.6.1.4.1.6066.2.1.1.3.3.6.1.1 |
mltCapacitanceCeqtgCapacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacitance will not be resolved. The equivalent capacitances CEQtr, CEQtg and CEQrg will be reported. They represent the following: CEQtr = Ctr + Ctg/4 + Crg/4 CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg) CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg) Capacitance measurements will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.ro Integer32 UNITS "nF" .1.3.6.1.4.1.6066.2.1.1.3.3.6.1.2 |
mltCapacitanceCeqrgCapacitance measurements will support only single element (2 terminal) circuit. In the presence of a network of capacitance (figure 3), the individual capacitance will not be resolved. The equivalent capacitances CEQtr, CEQtg and CEQrg will be reported. They represent the following: CEQtr = Ctr + Ctg/4 + Crg/4 CEQtg = Ctg + (Ctr*Crg)/(Ctr+Crg) CEQrg = Crg + (Ctr*Ctg)/Ctr+Ctg) Capacitance measurements will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.ro Integer32 UNITS "nF" .1.3.6.1.4.1.6066.2.1.1.3.3.6.1.3 |
mltCapacitanceErrorsIndicates GNK and/or OTEMP alarms active when test was run.ro OCTET STRING .1.3.6.1.4.1.6066.2.1.1.3.3.6.1.4 |
mltLoopDetectResultsTableThis table provides result of the mlt loop detect test. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured. SEQUENCE OF MltLoopDetectResultsEntry .1.3.6.1.4.1.6066.2.1.1.3.3.7 |
mltLoopDetectResultsEntryEntry holding information about results of mlt loop detect test. MltLoopDetectResultsEntry .1.3.6.1.4.1.6066.2.1.1.3.3.7.1 |
mltLoopDetectLoopCapacitanceLoop detection will be based on tip-ring capacitance measurement. User will be able to specify the detection threshold. If not supplied,loop detection threshold of 10 nF will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.ro Integer32 UNITS "nF" .1.3.6.1.4.1.6066.2.1.1.3.3.7.1.1 |
mltLoopDetectDetectionThresholdLoop detection will be based on tip-ring capacitance measurement. User will be able to specify the detection threshold. If not supplied, loop detection threshold of 10 nF will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.ro Integer32 UNITS "nF" .1.3.6.1.4.1.6066.2.1.1.3.3.7.1.2 |
mltLoopDetectLoopDetectedLoop detection will be based on tip-ring capacitance measurement. User will be able to specify the detection threshold. If not supplied, loop detection threshold of 10 nF will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.ro MltTestYesNo .1.3.6.1.4.1.6066.2.1.1.3.3.7.1.3 |
mltLoopDetectErrorsIndicates GNK and/or OTEMP alarms active when test was run.ro OCTET STRING .1.3.6.1.4.1.6066.2.1.1.3.3.7.1.4 |
mltLoopLengthResultsTableThis table provides result of the mlt loop length test. Note that a numerical result value of -999 means that there was an error of some sort and the value could not be measured. SEQUENCE OF MltLoopLengthResultsEntry .1.3.6.1.4.1.6066.2.1.1.3.3.8 |
mltLoopLengthResultsEntryEntry holding information about results of mlt loop length test. MltLoopLengthResultsEntry .1.3.6.1.4.1.6066.2.1.1.3.3.8.1 |
mltLoopLengthCapacitanceFactorLoop length estimate will be based on tip-ring capacitance measurement. User will be able to specify the loop length multiplier. If not supplied, loop length multiplier of 83 nF/ mile will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.ro Integer32 UNITS "nF/mile" .1.3.6.1.4.1.6066.2.1.1.3.3.8.1.1 |
mltLoopLengthLoopCapacitanceLoop length estimate will be based on tip-ring capacitance measurement. User will be able to specify the loop length multiplier. If not supplied, loop length multiplier of 83 nF/ mile will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.ro Integer32 UNITS "nF" .1.3.6.1.4.1.6066.2.1.1.3.3.8.1.2 |
mltLoopLengthLoopLengthLoop length estimate will be based on tip-ring capacitance measurement. User will be able to specify the loop length multiplier. If not supplied, loop length multiplier of 83 nF/ mile will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only.ro Integer32 UNITS "ft" .1.3.6.1.4.1.6066.2.1.1.3.3.8.1.3 |
mltLoopLengthUncompensatedLoopCapacitanceLoop length estimate will be based on tip-ring capacitance measurement. User will be able to specify the loop length multiplier. If not supplied, loop length multiplier of 83 nF/ mile will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only. This value has no DSL correction.ro Integer32 UNITS "nF" .1.3.6.1.4.1.6066.2.1.1.3.3.8.1.4 |
mltLoopLengthUncompensatedLoopLengthLoop length estimate will be based on tip-ring capacitance measurement. User will be able to specify the loop length multiplier. If not supplied, loop length multiplier of 83 nF/ mile will be used. This test will not be available if fuse test fails or alarm is present. This test is intrusive and will be available in shutdown state only. This value has no DSL correction.ro Integer32 UNITS "ft" .1.3.6.1.4.1.6066.2.1.1.3.3.8.1.5 |
mltLoopLengthErrorsIndicates GNK and/or OTEMP alarms active when test was run.ro OCTET STRING .1.3.6.1.4.1.6066.2.1.1.3.3.8.1.6 |
mltTestNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.6066.2.1.1.3.4 |
mltTestCompletedNotificationThis notification is sent to the requesting host when the requested mlt test has completed. NOTIFICATION-TYPE .1.3.6.1.4.1.6066.2.1.1.3.4.1 |