Nortel-Magellan-Passport-FrameRelayUniTraceMIB
AI MIB Summary
Standard SNMP MIB module defining data structures for Nortel-Magellan-Passport-FrameRelayUniTraceMIB.
36
Objects
Active
Status
5
Dependencies
Imported Objects
Objects
36 total| Object Name |
|---|
frameRelayUniTraceMIB OBJECT IDENTIFIER .1.3.6.1.4.1.562.2.4.2.105 |
IMPORTS Unknown .1.3.6.1.4.1.562.2.4.2.105 |
frameRelayUniTraceGroup OBJECT IDENTIFIER .1.3.6.1.4.1.562.2.4.2.105.1 |
frameRelayUniTraceGroupBD OBJECT IDENTIFIER .1.3.6.1.4.1.562.2.4.2.105.1.4 |
frameRelayUniTraceGroupBD01 OBJECT IDENTIFIER .1.3.6.1.4.1.562.2.4.2.105.1.4.2 |
frameRelayUniTraceGroupBD01A OBJECT IDENTIFIER .1.3.6.1.4.1.562.2.4.2.105.1.4.2.2 |
frameRelayUniTraceCapabilities OBJECT IDENTIFIER .1.3.6.1.4.1.562.2.4.2.105.3 |
frameRelayUniTraceCapabilitiesBD OBJECT IDENTIFIER .1.3.6.1.4.1.562.2.4.2.105.3.4 |
frameRelayUniTraceCapabilitiesBD01 OBJECT IDENTIFIER .1.3.6.1.4.1.562.2.4.2.105.3.4.2 |
frameRelayUniTraceCapabilitiesBD01A OBJECT IDENTIFIER .1.3.6.1.4.1.562.2.4.2.105.3.4.2.2 |
frUniTrace OBJECT IDENTIFIER .1.3.6.1.4.1.3764.1.1.30.71.7 |
frUniTraceRowStatusTableThis entry controls the addition and deletion of
frUniTrace components. SEQUENCE OF FrUniTraceRowStatusEntry .1.3.6.1.4.1.3764.1.1.30.71.7.1 |
frUniTraceRowStatusEntryA single entry in the table represents a single
frUniTrace component. FrUniTraceRowStatusEntry .1.3.6.1.4.1.3764.1.1.30.71.7.1.1 |
frUniTraceRowStatusThis variable is used as the basis for SNMP naming of
frUniTrace components.
These components can be added and deleted.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.3764.1.1.30.71.7.1.1.1 |
frUniTraceComponentNameThis variable provides the component's string name for
use with the ASCII Console Interfacero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3764.1.1.30.71.7.1.1.2 |
frUniTraceStorageTypeThis variable represents the storage type value for the
frUniTrace tables.ro StorageType (SNMPv2-TC) .1.3.6.1.4.1.3764.1.1.30.71.7.1.1.4 |
frUniTraceIndexThis variable represents the index for the frUniTrace tables. NonReplicated .1.3.6.1.4.1.3764.1.1.30.71.7.1.1.10 |
frUniTraceFilter OBJECT IDENTIFIER .1.3.6.1.4.1.3764.1.1.30.71.7.2 |
frUniTraceFilterRowStatusTableThis entry controls the addition and deletion of
frUniTraceFilter components. SEQUENCE OF FrUniTraceFilterRowStatusEntry .1.3.6.1.4.1.3764.1.1.30.71.7.2.1 |
frUniTraceFilterRowStatusEntryA single entry in the table represents a single
frUniTraceFilter component. FrUniTraceFilterRowStatusEntry .1.3.6.1.4.1.3764.1.1.30.71.7.2.1.1 |
frUniTraceFilterRowStatusThis variable is used as the basis for SNMP naming of
frUniTraceFilter components.
These components cannot be added nor deleted.ro RowStatus (SNMPv2-TC) .1.3.6.1.4.1.3764.1.1.30.71.7.2.1.1.1 |
frUniTraceFilterComponentNameThis variable provides the component's string name for
use with the ASCII Console Interfacero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3764.1.1.30.71.7.2.1.1.2 |
frUniTraceFilterStorageTypeThis variable represents the storage type value for the
frUniTraceFilter tables.ro StorageType (SNMPv2-TC) .1.3.6.1.4.1.3764.1.1.30.71.7.2.1.1.4 |
frUniTraceFilterIndexThis variable represents the index for the frUniTraceFilter tables. NonReplicated .1.3.6.1.4.1.3764.1.1.30.71.7.2.1.1.10 |
frUniTraceFilterOperationalTableThis group provides the operational attributes for the Frame Relay
Trace Filter component. SEQUENCE OF FrUniTraceFilterOperationalEntry .1.3.6.1.4.1.3764.1.1.30.71.7.2.10 |
frUniTraceFilterOperationalEntryAn entry in the frUniTraceFilterOperationalTable. FrUniTraceFilterOperationalEntry .1.3.6.1.4.1.3764.1.1.30.71.7.2.10.1 |
frUniTraceFilterTraceTypeThis attribute specifies the level of filtering required for this trace
session. A value of lmi indicates that Lmi frames are traced. A
value of dlci indicates that frames from the Dlci specified by the
tracedDlci attribute are traced. A value of badFrames indicates that
bad received frames (overruns, CRC errors, aborts) are traced. The
default is to trace all frames. This attribute can be set while a trace
is active and takes effect immediately.
Description of bits:
lmi(0)
dlci(1)
badFrames(2)rw OCTET STRING .1.3.6.1.4.1.3764.1.1.30.71.7.2.10.1.1 |
frUniTraceFilterTracedDlciThis attribute specifies a particular Dlci to trace. A value of zero
specifies that all Dlcis are to be traced. This attribute can be set
while a trace is active and takes effect immediately.rw Unsigned32 .1.3.6.1.4.1.3764.1.1.30.71.7.2.10.1.2 |
frUniTraceFilterDirectionThis attribute specifies the direction of the data to be traced as
viewed by the service. The values can be egress, and/or ingress. An
egress value indicates frames outbound from the service. An
ingress value indicates frames inbound to the service. This attribute
can be set while a trace is active and takes effect immediately.
Description of bits:
egress(0)
ingress(1)rw OCTET STRING .1.3.6.1.4.1.3764.1.1.30.71.7.2.10.1.3 |
frUniTraceFilterTracedLengthThis attribute specifies the maximum number of bytes to trace per
frame starting from the byte following the frame flag. If the frame
length is longer than the value specified by this attribute, then the
traced frame is truncated. This attribute can be set while a trace is
active and takes effect immediately.rw Unsigned32 .1.3.6.1.4.1.3764.1.1.30.71.7.2.10.1.4 |
frUniTraceOperationalTableThis group provides the operational attributes for the Trace
component. SEQUENCE OF FrUniTraceOperationalEntry .1.3.6.1.4.1.3764.1.1.30.71.7.10 |
frUniTraceOperationalEntryAn entry in the frUniTraceOperationalTable. FrUniTraceOperationalEntry .1.3.6.1.4.1.3764.1.1.30.71.7.10.1 |
frUniTraceReceiverNameThis attribute should be set to the name of the desired trace receiver
before starting a trace session. All available trace receivers are listed
under the Trace Rcvr/<string> component. This attribute cannot be
set while a trace is active.rw AsciiString .1.3.6.1.4.1.3764.1.1.30.71.7.10.1.2 |
frUniTraceDurationThis attribute specifies the duration, in minutes, of a trace session.
A value of 0 indicates unlimited duration in which case a trace
session remains active until a stop command is issued. The default
duration is 60 minutes. This attribute cannot be set while a trace is
active.rw Unsigned32 .1.3.6.1.4.1.3764.1.1.30.71.7.10.1.3 |
frUniTraceQueueLimitThis attribute specifies the total number of bytes of traced data
which may be queued for transmission to the trace receiver. When
this limit is exceeded, incoming traced frames are discarded. This
attribute can be set while a trace is active and takes effect
immediately.rw Unsigned32 .1.3.6.1.4.1.3764.1.1.30.71.7.10.1.4 |
frUniTraceSessionThis attribute is set automatically. It identifies the Trace Session
component which is forwarding the trace data. This attribute is
empty unless a trace is active.ro RowPointer .1.3.6.1.4.1.3764.1.1.30.71.7.10.1.5 |