Home/Catalog/Nortel-Magellan-Passport-FrameRelayNniTraceMIB

Nortel-Magellan-Passport-FrameRelayNniTraceMIB

AI MIB Summary

Standard SNMP MIB module defining data structures for Nortel-Magellan-Passport-FrameRelayNniTraceMIB.

36
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

36 total
Object Name
frameRelayNniTraceMIB
OBJECT IDENTIFIER
.1.3.6.1.4.1.562.2.4.2.106
IMPORTS
Unknown
.1.3.6.1.4.1.562.2.4.2.106
frameRelayNniTraceGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.562.2.4.2.106.1
frameRelayNniTraceGroupBD
OBJECT IDENTIFIER
.1.3.6.1.4.1.562.2.4.2.106.1.4
frameRelayNniTraceGroupBD01
OBJECT IDENTIFIER
.1.3.6.1.4.1.562.2.4.2.106.1.4.2
frameRelayNniTraceGroupBD01A
OBJECT IDENTIFIER
.1.3.6.1.4.1.562.2.4.2.106.1.4.2.2
frameRelayNniTraceCapabilities
OBJECT IDENTIFIER
.1.3.6.1.4.1.562.2.4.2.106.3
frameRelayNniTraceCapabilitiesBD
OBJECT IDENTIFIER
.1.3.6.1.4.1.562.2.4.2.106.3.4
frameRelayNniTraceCapabilitiesBD01
OBJECT IDENTIFIER
.1.3.6.1.4.1.562.2.4.2.106.3.4.2
frameRelayNniTraceCapabilitiesBD01A
OBJECT IDENTIFIER
.1.3.6.1.4.1.562.2.4.2.106.3.4.2.2
frNniTrace
OBJECT IDENTIFIER
.1.3.6.1.4.1.3764.1.1.30.70.7
frNniTraceRowStatusTableThis entry controls the addition and deletion of frNniTrace components.
SEQUENCE OF FrNniTraceRowStatusEntry
.1.3.6.1.4.1.3764.1.1.30.70.7.1
frNniTraceRowStatusEntryA single entry in the table represents a single frNniTrace component.
FrNniTraceRowStatusEntry
.1.3.6.1.4.1.3764.1.1.30.70.7.1.1
frNniTraceRowStatusThis variable is used as the basis for SNMP naming of frNniTrace components. These components can be added and deleted.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.3764.1.1.30.70.7.1.1.1
frNniTraceComponentNameThis variable provides the component's string name for use with the ASCII Console Interfacero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3764.1.1.30.70.7.1.1.2
frNniTraceStorageTypeThis variable represents the storage type value for the frNniTrace tables.ro
StorageType (SNMPv2-TC)
.1.3.6.1.4.1.3764.1.1.30.70.7.1.1.4
frNniTraceIndexThis variable represents the index for the frNniTrace tables.
NonReplicated
.1.3.6.1.4.1.3764.1.1.30.70.7.1.1.10
frNniTraceFilter
OBJECT IDENTIFIER
.1.3.6.1.4.1.3764.1.1.30.70.7.2
frNniTraceFilterRowStatusTableThis entry controls the addition and deletion of frNniTraceFilter components.
SEQUENCE OF FrNniTraceFilterRowStatusEntry
.1.3.6.1.4.1.3764.1.1.30.70.7.2.1
frNniTraceFilterRowStatusEntryA single entry in the table represents a single frNniTraceFilter component.
FrNniTraceFilterRowStatusEntry
.1.3.6.1.4.1.3764.1.1.30.70.7.2.1.1
frNniTraceFilterRowStatusThis variable is used as the basis for SNMP naming of frNniTraceFilter components. These components cannot be added nor deleted.ro
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.3764.1.1.30.70.7.2.1.1.1
frNniTraceFilterComponentNameThis variable provides the component's string name for use with the ASCII Console Interfacero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3764.1.1.30.70.7.2.1.1.2
frNniTraceFilterStorageTypeThis variable represents the storage type value for the frNniTraceFilter tables.ro
StorageType (SNMPv2-TC)
.1.3.6.1.4.1.3764.1.1.30.70.7.2.1.1.4
frNniTraceFilterIndexThis variable represents the index for the frNniTraceFilter tables.
NonReplicated
.1.3.6.1.4.1.3764.1.1.30.70.7.2.1.1.10
frNniTraceFilterOperationalTableThis group provides the operational attributes for the Frame Relay Trace Filter component.
SEQUENCE OF FrNniTraceFilterOperationalEntry
.1.3.6.1.4.1.3764.1.1.30.70.7.2.10
frNniTraceFilterOperationalEntryAn entry in the frNniTraceFilterOperationalTable.
FrNniTraceFilterOperationalEntry
.1.3.6.1.4.1.3764.1.1.30.70.7.2.10.1
frNniTraceFilterTraceTypeThis attribute specifies the level of filtering required for this trace session. A value of lmi indicates that Lmi frames are traced. A value of dlci indicates that frames from the Dlci specified by the tracedDlci attribute are traced. A value of badFrames indicates that bad received frames (overruns, CRC errors, aborts) are traced. The default is to trace all frames. This attribute can be set while a trace is active and takes effect immediately. Description of bits: lmi(0) dlci(1) badFrames(2)rw
OCTET STRING
.1.3.6.1.4.1.3764.1.1.30.70.7.2.10.1.1
frNniTraceFilterTracedDlciThis attribute specifies a particular Dlci to trace. A value of zero specifies that all Dlcis are to be traced. This attribute can be set while a trace is active and takes effect immediately.rw
Unsigned32
.1.3.6.1.4.1.3764.1.1.30.70.7.2.10.1.2
frNniTraceFilterDirectionThis attribute specifies the direction of the data to be traced as viewed by the service. The values can be egress, and/or ingress. An egress value indicates frames outbound from the service. An ingress value indicates frames inbound to the service. This attribute can be set while a trace is active and takes effect immediately. Description of bits: egress(0) ingress(1)rw
OCTET STRING
.1.3.6.1.4.1.3764.1.1.30.70.7.2.10.1.3
frNniTraceFilterTracedLengthThis attribute specifies the maximum number of bytes to trace per frame starting from the byte following the frame flag. If the frame length is longer than the value specified by this attribute, then the traced frame is truncated. This attribute can be set while a trace is active and takes effect immediately.rw
Unsigned32
.1.3.6.1.4.1.3764.1.1.30.70.7.2.10.1.4
frNniTraceOperationalTableThis group provides the operational attributes for the Trace component.
SEQUENCE OF FrNniTraceOperationalEntry
.1.3.6.1.4.1.3764.1.1.30.70.7.10
frNniTraceOperationalEntryAn entry in the frNniTraceOperationalTable.
FrNniTraceOperationalEntry
.1.3.6.1.4.1.3764.1.1.30.70.7.10.1
frNniTraceReceiverNameThis attribute should be set to the name of the desired trace receiver before starting a trace session. All available trace receivers are listed under the Trace Rcvr/<string> component. This attribute cannot be set while a trace is active.rw
AsciiString
.1.3.6.1.4.1.3764.1.1.30.70.7.10.1.2
frNniTraceDurationThis attribute specifies the duration, in minutes, of a trace session. A value of 0 indicates unlimited duration in which case a trace session remains active until a stop command is issued. The default duration is 60 minutes. This attribute cannot be set while a trace is active.rw
Unsigned32
.1.3.6.1.4.1.3764.1.1.30.70.7.10.1.3
frNniTraceQueueLimitThis attribute specifies the total number of bytes of traced data which may be queued for transmission to the trace receiver. When this limit is exceeded, incoming traced frames are discarded. This attribute can be set while a trace is active and takes effect immediately.rw
Unsigned32
.1.3.6.1.4.1.3764.1.1.30.70.7.10.1.4
frNniTraceSessionThis attribute is set automatically. It identifies the Trace Session component which is forwarding the trace data. This attribute is empty unless a trace is active.ro
RowPointer
.1.3.6.1.4.1.3764.1.1.30.70.7.10.1.5
Nortel-Magellan-Passport-FrameRelayNniTraceMIB - SNMP MIB Reference | MIBs Explorer