NSS324-MIB
Standard SNMP MIB module defining data structures for NSS324-MIB.
Imported Objects
Objects
59 total| Object Name |
|---|
cisco OBJECT IDENTIFIER .1.3.6.1.4.1.9 |
RFC1155-SMI Unknown .1.3.6.1.4.1.9 |
otherEnterprises OBJECT IDENTIFIER .1.3.6.1.4.1.9.6 |
ciscoSB OBJECT IDENTIFIER .1.3.6.1.4.1.9.6.1 |
nas004 OBJECT IDENTIFIER .1.3.6.1.4.1.9.6.1.103 |
nss OBJECT IDENTIFIER .1.3.6.1.4.1.9.6.1.103.41 |
nss324 OBJECT IDENTIFIER .1.3.6.1.4.1.9.6.1.103.41.324 |
nssAthens MODULE-IDENTITY .1.3.6.1.4.1.9.6.1.103.41.324.114 |
storageSystem OBJECT IDENTIFIER .1.3.6.1.4.1.9.6.1.103.41.324.114.1 |
systemEventMsg OBJECT IDENTIFIER .1.3.6.1.4.1.9.6.1.103.41.324.114.1.1 |
eventInformMsgInformation event of NAS system.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.9.6.1.103.41.324.114.1.1.101 |
eventWarningMsgWarning event of NAS system.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.9.6.1.103.41.324.114.1.1.102 |
eventErrorMsgError event of NAS system.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.9.6.1.103.41.324.114.1.1.103 |
systemInfo OBJECT IDENTIFIER .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2 |
systemCPU-UsageSystem CPU usagero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.1 |
systemTotalMemSystem total memoryro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.2 |
systemFreeMemSystem free memoryro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.3 |
systemUptimeThe amount of time since this host was last
initialized. Note that this is different from
sysUpTime in the SNMPv2-MIB [RFC1907] because
sysUpTime is the uptime of the network management
portion of the system.ro TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.4 |
cpu-TemperatureCPU temperaturero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.5 |
systemTemperatureSystem temperaturero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.6 |
ifNumberThe number of network interfaces (regardless of
their current state) present on this system.ro INTEGER .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.8 |
systemIfTableA list of interface entries. The number of
entries is given by the value of ifNumber. SEQUENCE OF IfEntryDef .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.9 |
ifEntryAn interface entry containing objects at the
subnetwork layer and below for a particular
interface. IfEntryDef .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.9.1 |
ifIndexA unique value for each interface. Its value
ranges between 1 and the value of ifNumber. The
value for each interface must remain constant at
least from one re-initialization of the entity's
network management system to the next re-
initialization.ro INTEGER .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.9.1.1 |
ifDescrA textual string containing information about the
interface. This string should include the name of
the manufacturer, the product name and the version
of the hardware interface.ro DisplayString .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.9.1.2 |
ifPacketsReceivedSystem packets received.ro Counter .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.9.1.3 |
ifPacketsSentSystem packets sent.ro Counter .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.9.1.4 |
ifErrorPacketsSystem error packets.ro Counter .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.9.1.5 |
hdNumberThe number of hard disk (regardless of
their current state) present on this system.ro INTEGER .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.10 |
systemHdTableA list of interface entries. The number of
entries is given by the value of ifNumber. SEQUENCE OF HdEntryDef .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.11 |
hdEntryAn interface entry containing objects at the
subnetwork layer and below for a particular
interface. HdEntryDef .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.11.1 |
hdIndexA unique value for each hard disk. Its value
ranges between 1 and the value of ifNumber. The
value for each interface must remain constant at
least from one re-initialization of the entity's
network management system to the next re-
initialization.ro INTEGER .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.11.1.1 |
hdDescrA textual string containing information about the
interface. This string should include the name of
the manufacturer, the product name and the version
of the hardware interface.ro DisplayString .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.11.1.2 |
hdTemperatureHard disk temperature.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.11.1.3 |
hdStatusHDD status. 0:not availible, 1:availible.ro Enumeration .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.11.1.4 |
hdModelHard disk model.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.11.1.5 |
hdCapacityHard disk capacity.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.11.1.6 |
hdSmartInfoHard disk SMART information.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.11.1.7 |
modelNameModel namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.12 |
hostNameModel namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.13 |
sysFanNumberThe number of system fan (regardless of
their current state) present on this system.ro INTEGER .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.14 |
systemFanTableA list of interface entries. The number of
entries is given by the value of sysFanNumber. SEQUENCE OF SysFanEntryDef .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.15 |
sysFanEntryAn system fan entry containing objects at the
subnetwork layer and below for a particular
interface. SysFanEntryDef .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.15.1 |
sysFanIndexA unique value for each system fan. Its value
ranges between 1 and the value of sysFanNumber. The
value for each interface must remain constant at
least from one re-initialization of the entity's
network management system to the next re-
initialization.ro INTEGER .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.15.1.1 |
sysFanDescrA textual string containing information about the
interface. This string should include the name of
the manufacturer, the product name and the version
of the hardware interface.ro DisplayString .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.15.1.2 |
sysFanSpeedSystem fan speed.ro DisplayString .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.15.1.3 |
sysVolumeNumberThe number of system volumes (regardless of
their current state) present on this system.ro INTEGER .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.16 |
systemVolumeTableA list of volume entries. The number of
entries is given by the value of sysVolumeNumber. SEQUENCE OF SysVolumeEntryDef .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.17 |
sysVolumeEntryAn system volume entry SysVolumeEntryDef .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.17.1 |
sysVolumeIndexA unique value for each system volume. Its value
ranges between 1 and the value of sysVolumeNumber. The
value for each volume must remain constant at
least from one re-initialization of the entity's
volume system to the next re-initialization.ro INTEGER .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.17.1.1 |
sysVolumeDescrA textual string containing information about the volume.ro DisplayString .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.17.1.2 |
sysVolumeFSSystem Volume file system.ro DisplayString .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.17.1.3 |
sysVolumeTotalSizeSystem Volume total size.ro DisplayString .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.17.1.4 |
sysVolumeFreeSizeSystem Volume free size.ro DisplayString .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.17.1.5 |
sysVolumeStatusSystem Volume status.ro DisplayString .1.3.6.1.4.1.9.6.1.103.41.324.114.1.2.17.1.6 |
systemTraps OBJECT IDENTIFIER .1.3.6.1.4.1.9.6.1.103.41.324.114.1.10 |
eventInformInfo: %s TRAP-TYPE .1.3.6.1.4.1.9.6.1.103.41.324.114.1.10.0.1 |
eventWarningWarn: %s TRAP-TYPE .1.3.6.1.4.1.9.6.1.103.41.324.114.1.10.0.2 |
eventErrorError: %s TRAP-TYPE .1.3.6.1.4.1.9.6.1.103.41.324.114.1.10.0.4 |
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-ENTITY-VENDORTYPE-OID-MIB maps Cisco-specific hardware component identifiers to the ENTITY-MIB's entPhysicalTable, enabling precise differentiation of physical device types such as line cards, power supplies, and fans within Cisco infrastructure. This mapping ensures that SNMP management systems can accurately correlate physical inventory entries with vendor-specific component definitions for accurate device discovery and monitoring.
The CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB provides SNMP-based monitoring and management of Cisco Unified Computing System (UCS) hardware components, including chassis, blades, fabric interconnects, and power supplies. It exposes critical operational metrics such as device status, port states, temperature readings, fan speeds, and power consumption data for infrastructure health assessment.
The CISCO-UNIFIED-COMPUTING-ADAPTOR-MIB enables SNMP-based monitoring and management of physical and virtual network adapter interfaces, including link status, traffic counters, error statistics, and port configuration parameters, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers.
The CISCO-UNIFIED-COMPUTING-TC-MIB module defines standard textual conventions and data type definitions required for monitoring Cisco Unified Computing System (UCS) hardware components, including server blades, fabric interconnects, and chassis resources. These definitions enable consistent interpretation of specific UCS metrics such as power supply status, fan speeds, thermal readings, and port utilization across SNMP management applications.
The CISCO-UNIFIED-COMPUTING-FABRIC-MIB enables SNMP-based monitoring and management of the Cisco UCS Fabric Interconnects and associated fabric switching infrastructure, exposing metrics for port states, link utilization, error counters, and fabric topology status. It facilitates granular visibility into the physical and logical fabric layers, including uplink/downlink interfaces, VLAN configurations, and fabric failover conditions within the unified computing environment.
The STARENT-MIB module provides SNMP management and monitoring capabilities for Cisco ASR 5000 and ASR 5500 multimedia core platforms, specifically exposing metrics related to 2G/3G/4G and WiFi subscriber sessions, inline service states, and carrier-class high-availability status.