NMS-SYS-MIB
The NMS-SYS-MIB defines vendor-specific private extensions for Network Management System agents to expose proprietary hardware telemetry and system state variables not covered by standard MIBs. These nodes typically facilitate the monitoring of device-specific metrics such as proprietary error counters, internal sensor readings, and custom operational parameters required for granular fault isolation.
Imported Objects
Objects
35 total| Object Name |
|---|
sys OBJECT IDENTIFIER .1.3.6.1.4.1.56166.1.2 |
sysModuleDefine system private MIB nodes for NMS. MODULE-IDENTITY .1.3.6.1.4.1.56166.1.2.1 |
cpuUtilizedThe percentage of the processor's operating time, calculated over the last minute.ro Integer32 .1.3.6.1.4.1.56166.1.2.1.1 |
memUtilizedThe percentage of real/physical memory currently used or unavailable.ro Integer32 .1.3.6.1.4.1.56166.1.2.1.2 |
cpuIdleThe percentage of processor time spent idle, calculated over the last minute.ro Integer32 .1.3.6.1.4.1.56166.1.2.1.3 |
memTotalRealThe total amount of real/physical memory installed on this host.ro Integer32 UNITS "kB" .1.3.6.1.4.1.56166.1.2.1.4 |
memAvailRealThe amount of real/physical memory currently unused or available.ro Integer32 UNITS "kB" .1.3.6.1.4.1.56166.1.2.1.5 |
operations OBJECT IDENTIFIER .1.3.6.1.4.1.56166.1.2.2 |
configurationOperDevice's configuration operations.rw Enumeration .1.3.6.1.4.1.56166.1.2.2.1 |
powerOperDevice's power operations.rw Enumeration .1.3.6.1.4.1.56166.1.2.2.2 |
powerTableThe table of power supply status. SEQUENCE OF PowerEntry .1.3.6.1.4.1.56166.1.2.3 |
powerEntryThe entry of power supply status. PowerEntry .1.3.6.1.4.1.56166.1.2.3.1 |
powerIndexPower index for multi power supplied.ro Gauge32 .1.3.6.1.4.1.56166.1.2.3.1.1 |
powerTypePower type.ro Enumeration .1.3.6.1.4.1.56166.1.2.3.1.2 |
powerStatePower state, on/off.rw Enumeration .1.3.6.1.4.1.56166.1.2.3.1.3 |
powerVoltagePower voltage.rw Integer32 .1.3.6.1.4.1.56166.1.2.3.1.4 |
temperatureTableThe temperature sensor state table. SEQUENCE OF TemperatureEntry .1.3.6.1.4.1.56166.1.2.4 |
temperatureEntryThe temperature sensor state table. TemperatureEntry .1.3.6.1.4.1.56166.1.2.4.1 |
temperatureIndexDevice temperature sensor index.ro Integer32 .1.3.6.1.4.1.56166.1.2.4.1.1 |
temperatureValueThe value of the device temperature sensor, in degrees Celsius.ro Integer32 .1.3.6.1.4.1.56166.1.2.4.1.2 |
fanStatusTableFan status table. SEQUENCE OF FanStatusEntry .1.3.6.1.4.1.56166.1.2.5 |
fanStatusEntryFan status entry. FanStatusEntry .1.3.6.1.4.1.56166.1.2.5.1 |
fanIndexFan index.ro Integer32 .1.3.6.1.4.1.56166.1.2.5.1.1 |
fanSpeedStatusFan speed status.ro Enumeration .1.3.6.1.4.1.56166.1.2.5.1.2 |
fanStatusFan status.ro Enumeration .1.3.6.1.4.1.56166.1.2.5.1.3 |
sysTraps OBJECT IDENTIFIER .1.3.6.1.4.1.56166.1.2.7 |
powerChangeNotify power events, like on/off/low/recovery. NOTIFICATION-TYPE .1.3.6.1.4.1.56166.1.2.7.1 |
batteryLowNotify battery low event. NOTIFICATION-TYPE .1.3.6.1.4.1.56166.1.2.7.2 |
batteryRecoverNotify battery recover event. NOTIFICATION-TYPE .1.3.6.1.4.1.56166.1.2.7.3 |
fanFailureNotify fan failure event. NOTIFICATION-TYPE .1.3.6.1.4.1.56166.1.2.7.4 |
fanNormalNotify fan recover event. NOTIFICATION-TYPE .1.3.6.1.4.1.56166.1.2.7.5 |
fanSpeedStatusChangeNotify fan speed status change event. NOTIFICATION-TYPE .1.3.6.1.4.1.56166.1.2.7.6 |
sysGroups OBJECT IDENTIFIER .1.3.6.1.4.1.56166.1.2.8 |
sysTableGroupTable & scalar nodes group. Unknown .1.3.6.1.4.1.56166.1.2.8.1 |
sysTrapGroupTrap nodes group. Unknown .1.3.6.1.4.1.56166.1.2.8.2 |
More MIBs from Nms
Browse all NmsMIBs →The NMS-OPTICAL-MIB module enables monitoring and management of optical transceiver parameters, including transmit/receive optical power, bias current, temperature, and supply voltage, across network interface cards and pluggable optical modules. It provides the standardized data nodes required for NMS systems to track link health, detect degradation, and manage optical module inventory in high-speed transport networks.
The NMS MIB module defines a private enterprise namespace for aggregating proprietary management data points, typically serving as a container for vendor-specific counters, status flags, and configuration parameters required by Network Management Systems to monitor device health and operational state.