NMS-EPON-ONU-PARAM
AI MIB Summary
Standard SNMP MIB module defining data structures for NMS-EPON-ONU-PARAM.
41
Objects
Active
Status
5
Dependencies
Imported Objects
Objects
41 total| Object Name |
|---|
nmsOnuPerfNotif OBJECT IDENTIFIER .1.3.6.1.4.1.3320.101.18.8 |
paraStatusDescription.rw Enumeration .1.3.6.1.4.1.3320.101.18.8.1 |
nmsOnuPerfNotifV2Root node for the converted TRAP-TYPEs. OBJECT IDENTIFIER .1.3.6.1.4.1.3320.101.18.8.2 |
onuPerformParameterAlarmDescription. NOTIFICATION-TYPE .1.3.6.1.4.1.3320.101.18.8.2.2 |
nmsOnuPerf OBJECT IDENTIFIER .1.3.6.1.4.1.3320.101.201 |
IMPORTS Unknown .1.3.6.1.4.1.3320.101.201 |
nmsOnuPerfSet OBJECT IDENTIFIER .1.3.6.1.4.1.3320.101.201.1 |
onuPerformParameterAlarmsSetTableDescription. SEQUENCE OF OnuPerformParameterAlarmsSetEntry .1.3.6.1.4.1.3320.101.201.1.1 |
onuPerformParameterAlarmsSetEntryDescription. OnuPerformParameterAlarmsSetEntry .1.3.6.1.4.1.3320.101.201.1.1.1 |
llidIfIndexIndex of LLID interface.ro INTEGER .1.3.6.1.4.1.3320.101.201.1.1.1.1 |
cpuUsageHighLimitEnableEnable or disable the alarm of CPU usage. 1-enable, 2-disable. Default is disable.rw Enumeration .1.3.6.1.4.1.3320.101.201.1.1.1.2 |
cpuUsageHighLimitThresholdThe upper threshold of CPU usage alarm. The unit is 1%. The range is 1-100. Default is 100.rw INTEGER .1.3.6.1.4.1.3320.101.201.1.1.1.3 |
cpuUsageHighLimitClearThresholdThe upper threshold of CPU usage alarm cleared. The range is 1-100. Default is 100.rw INTEGER .1.3.6.1.4.1.3320.101.201.1.1.1.4 |
cpuUsageHighLimitRowStatusThe row status of CPU usage alarm .rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.3320.101.201.1.1.1.5 |
ramUsageHighLimitEnableEnable or disable the alarm of RAM usage. 1-enable, 2-disable. Default is disable.rw Enumeration .1.3.6.1.4.1.3320.101.201.1.1.1.6 |
ramUsageHighLimitThresholdThe upper threshold of RAM usage alarm. The unit is 1%. The range is 1-100. Default is 100.rw INTEGER .1.3.6.1.4.1.3320.101.201.1.1.1.7 |
ramUsageHighLimitClearThresholdThe upper threshold of RAM usage alarm cleared. The range is 1-100. Default is 100.rw INTEGER .1.3.6.1.4.1.3320.101.201.1.1.1.8 |
ramUsageHighLimitRowStatusThe row status of RAM usage alarm .rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.3320.101.201.1.1.1.9 |
temperatureAlarmUpLimitEnableEnable or disable the alarm of PON high temperature. 1-enable, 2-disable. Default is disable.rw Enumeration .1.3.6.1.4.1.3320.101.201.1.1.1.10 |
temperatureAlarmUpLimitThresholdThe upper threshold of temperature alarm. The unit is 0.1 degree. The range is -1280-1280. Default is 1280.rw INTEGER(-1280..1280) .1.3.6.1.4.1.3320.101.201.1.1.1.11 |
temperatureAlarmUpLimitClearThresholdThe upper threshold temperature alarm cleared. The unit is 0.1 degree. The range is -1280-1280. Default is 1280.rw INTEGER(-1280..1280) .1.3.6.1.4.1.3320.101.201.1.1.1.12 |
temperatureAlarmUpLimitRowStatusThe row status of temperature upper alarm.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.3320.101.201.1.1.1.13 |
temperatureAlarmLowLimitEnableEnable or disable the alarm of PON low temperature. 1-enable, 2-disable. Default is disable.rw Enumeration .1.3.6.1.4.1.3320.101.201.1.1.1.14 |
temperatureAlarmLowLimitThresholdThe low threshold of temperature alarm. The unit is 0.1 degree. The range is -1280-1280. Default is -1280.rw INTEGER(-1280..1280) .1.3.6.1.4.1.3320.101.201.1.1.1.15 |
temperatureAlarmLowLimitClearThresholdThe low threshold temperature alarm cleared. The unit is 0.1 degree. The range is -1280-1280. Default is -1280.rw INTEGER(-1280..1280) .1.3.6.1.4.1.3320.101.201.1.1.1.16 |
temperatureAlarmLowLimitRowStatusThe row status of temperature low alarm.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.3320.101.201.1.1.1.17 |
voltageAlarmUpLimitEnableEnable or disable the alarm of PON high voltage. 1-enable, 2-disable. Default is disable.rw Enumeration .1.3.6.1.4.1.3320.101.201.1.1.1.18 |
voltageAlarmUpLimitThresholdThe upper threshold of voltage alarm. The unit is 0.1V. The range is 0-65. Default is 65.rw INTEGER .1.3.6.1.4.1.3320.101.201.1.1.1.19 |
voltageAlarmUpLimitClearThresholdThe upper threshold voltage alarm cleared. The unit is 0.1V. The range is 0-65. Default is 65.rw INTEGER .1.3.6.1.4.1.3320.101.201.1.1.1.20 |
voltageAlarmUpLimitRowStatusThe row status of voltage upper alarm.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.3320.101.201.1.1.1.21 |
voltageAlarmLowLimitEnableEnable or disable the alarm of PON low voltage. 1-enable, 2-disable. Default is disable.rw Enumeration .1.3.6.1.4.1.3320.101.201.1.1.1.22 |
voltageAlarmLowLimitThresholdThe low threshold of voltage alarm. The unit is 0.1V. The range is 0-65. Default is 0.rw INTEGER .1.3.6.1.4.1.3320.101.201.1.1.1.23 |
voltageAlarmLowLimitClearThresholdThe low threshold voltage alarm cleared. The unit is 0.1V. The range is 0-65. Default is 0.rw INTEGER .1.3.6.1.4.1.3320.101.201.1.1.1.24 |
voltageAlarmLowLimitRowStatusThe row status of voltage low alarm.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.3320.101.201.1.1.1.25 |
onuPerformParameterTableDescription. SEQUENCE OF OnuPerformParameterEntry .1.3.6.1.4.1.3320.101.201.1.2 |
onuPerformParameterEntryDescription. OnuPerformParameterEntry .1.3.6.1.4.1.3320.101.201.1.2.1 |
ifIndexIndex of LLID interface.rw INTEGER .1.3.6.1.4.1.3320.101.201.1.2.1.1 |
cpuUsageCPU usage . The unit is 1%. The range is 1-100. Default is 0.rw INTEGER .1.3.6.1.4.1.3320.101.201.1.2.1.2 |
ramUsageRAM usage. The unit is 1%. The range is 1-100. Default is 0.rw INTEGER .1.3.6.1.4.1.3320.101.201.1.2.1.3 |
temperatureTemperature.The unit is 0.1 degree. The range is -1280-1280. Default is 0.rw INTEGER (-1280..1280) .1.3.6.1.4.1.3320.101.201.1.2.1.4 |
voltageVoltage.The unit is 0.1V. The range is 0-65. Default is 0.rw INTEGER .1.3.6.1.4.1.3320.101.201.1.2.1.5 |