NMS-EPON-ONU-OPTICAL-PARAM-ALARM-SET
AI MIB Summary
Standard SNMP MIB module defining data structures for NMS-EPON-ONU-OPTICAL-PARAM-ALARM-SET.
44
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
44 total| Object Name |
|---|
onuOpticsParameterAlarmSet OBJECT IDENTIFIER .1.3.6.1.4.1.3320.101.10.6 |
onuOpticsParameterAlarmSetTableA list of epon onu Optics Parameter Alarm Set table entries. SEQUENCE OF OnuOpticsParameterAlarmSetEntry .1.3.6.1.4.1.3320.101.10.6.1 |
onuOpticsParameterAlarmSetEntryA collection of additional objects in the
epon onu Optics Parameter AlarmSet property table. OnuOpticsParameterAlarmSetEntry .1.3.6.1.4.1.3320.101.10.6.1.1 |
ifIndexThe only llid of ONU device in System.ro INTEGER .1.3.6.1.4.1.3320.101.10.6.1.1.1 |
txPowerAlarmUpLimitEnableEnable or disable the alarm of PON hign TX power. 1-enable, 2-disable. Default is disable.rw Enumeration .1.3.6.1.4.1.3320.101.10.6.1.1.2 |
txPowerAlarmUpLimitThresholdThe upper threshold of tx power alarm. The unit is 0.1DBm. The range is -400-82. Default is 82.rw INTEGER(-400..82) .1.3.6.1.4.1.3320.101.10.6.1.1.3 |
txPowerAlarmUpLimitClearThresholdThe upper threshold of tx power alarm. The unit is 0.1DBm. The range is -400-82. Default is 82.rw INTEGER(-400..82) .1.3.6.1.4.1.3320.101.10.6.1.1.4 |
txPowerAlarmUpLimitRowStatusThe row status of tx power upper alarm.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.3320.101.10.6.1.1.5 |
txPowerAlarmLowLimitEnableEnable or disable the alarm of PON low TX power. 1-enable, 2-disable. Default is disable.rw Enumeration .1.3.6.1.4.1.3320.101.10.6.1.1.6 |
txPowerAlarmLowLimitThresholdThe low threshold of tx power alarm. The unit is 0.1DBm. The range is -400-82. Default is -400.rw INTEGER(-400..82) .1.3.6.1.4.1.3320.101.10.6.1.1.7 |
txPowerAlarmLowLimitClearThresholdThe low threshold tx power alarm cleared. The unit is 0.1DBm. The range is -400-82. Default is -400.rw INTEGER(-400..82) .1.3.6.1.4.1.3320.101.10.6.1.1.8 |
txPowerAlarmLowLimitRowStatusThe row status of tx power low alarm.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.3320.101.10.6.1.1.9 |
rxPowerAlarmUpLimitEnableEnable or disable the alarm of PON hign RX power. 1-enable, 2-disable. Default is disable.rw Enumeration .1.3.6.1.4.1.3320.101.10.6.1.1.10 |
rxPowerAlarmUpLimitThresholdThe upper threshold of rx power alarm. The unit is 0.1DBm. The range is -400-82. Default is 82.rw INTEGER(-400..82) .1.3.6.1.4.1.3320.101.10.6.1.1.11 |
rxPowerAlarmUpLimitClearThresholdThe upper threshold rx power alarm cleared. The unit is 0.1DBm. The range is -400-82. Default is 82.rw INTEGER(-400..82) .1.3.6.1.4.1.3320.101.10.6.1.1.12 |
rxPowerAlarmUpLimitRowStatusThe row status of rx power upper alarm.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.3320.101.10.6.1.1.13 |
rxPowerAlarmLowLimitEnableEnable or disable the alarm of PON low RX power. 1-enable, 2-disable. Default is disable.rw Enumeration .1.3.6.1.4.1.3320.101.10.6.1.1.14 |
rxPowerAlarmLowLimitThresholdThe low threshold of rx power alarm. The unit is 0.1DBm. The range is -400-82. Default is -400.rw INTEGER(-400..82) .1.3.6.1.4.1.3320.101.10.6.1.1.15 |
rxPowerAlarmLowLimitClearThresholdThe low threshold rx power alarm cleared. The unit is 0.1DBm. The range is -400-82. Default is -400.rw INTEGER(-400..82) .1.3.6.1.4.1.3320.101.10.6.1.1.16 |
rxPowerAlarmLowLimitRowStatusThe row status of rx power low alarm.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.3320.101.10.6.1.1.17 |
temperatureAlarmUpLimitEnableEnable or disable the alarm of PON high temperature. 1-enable, 2-disable. Default is disable.rw Enumeration .1.3.6.1.4.1.3320.101.10.6.1.1.18 |
temperatureAlarmUpLimitThresholdThe upper threshold of temperature alarm. The unit is 0.1 degree. The range is -1280-1280. Default is 1280.rw INTEGER(-1280..1280) .1.3.6.1.4.1.3320.101.10.6.1.1.19 |
temperatureAlarmUpLimitClearThresholdThe upper threshold temperature alarm cleared. The unit is 0.1 degree. The range is -1280-1280. Default is 1280.rw INTEGER(-1280..1280) .1.3.6.1.4.1.3320.101.10.6.1.1.20 |
temperatureAlarmUpLimitRowStatusThe row status of temperature upper alarm.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.3320.101.10.6.1.1.21 |
temperatureAlarmLowLimitEnableEnable or disable the alarm of PON low temperature. 1-enable, 2-disable. Default is disable.rw Enumeration .1.3.6.1.4.1.3320.101.10.6.1.1.22 |
temperatureAlarmLowLimitThresholdThe low threshold of temperature alarm. The unit is 0.1 degree. The range is -1280-1280. Default is -1280.rw INTEGER(-1280..1280) .1.3.6.1.4.1.3320.101.10.6.1.1.23 |
temperatureAlarmLowLimitClearThresholdThe low threshold temperature alarm cleared. The unit is 0.1 degree. The range is -1280-1280. Default is -1280.rw INTEGER(-1280..1280) .1.3.6.1.4.1.3320.101.10.6.1.1.24 |
temperatureAlarmLowLimitRowStatusThe row status of temperature low alarm.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.3320.101.10.6.1.1.25 |
voltageAlarmUpLimitEnableEnable or disable the alarm of PON high voltage. 1-enable, 2-disable. Default is disable.rw Enumeration .1.3.6.1.4.1.3320.101.10.6.1.1.26 |
voltageAlarmUpLimitThresholdThe upper threshold of voltage alarm. The unit is 0.1V. The range is 0-65. Default is 65.rw INTEGER .1.3.6.1.4.1.3320.101.10.6.1.1.27 |
voltageAlarmUpLimitClearThresholdThe upper threshold voltage alarm cleared. The unit is 0.1V. The range is 0-65. Default is 65.rw INTEGER .1.3.6.1.4.1.3320.101.10.6.1.1.28 |
voltageAlarmUpLimitRowStatusThe row status of voltage upper alarm.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.3320.101.10.6.1.1.29 |
voltageAlarmLowLimitEnableEnable or disable the alarm of PON low voltage. 1-enable, 2-disable. Default is disable.rw Enumeration .1.3.6.1.4.1.3320.101.10.6.1.1.30 |
voltageAlarmLowLimitThresholdThe low threshold of voltage alarm. The unit is 0.1V. The range is 0-65. Default is 0.rw INTEGER .1.3.6.1.4.1.3320.101.10.6.1.1.31 |
voltageAlarmLowLimitClearThresholdThe low threshold voltage alarm cleared. The unit is 0.1V. The range is 0-65. Default is 0.rw INTEGER .1.3.6.1.4.1.3320.101.10.6.1.1.32 |
voltageAlarmLowLimitRowStatusThe row status of voltage low alarm.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.3320.101.10.6.1.1.33 |
currentAlarmUpLimitEnableEnable or disable the alarm of PON high current. 1-enable, 2-disable. Default is disable.rw Enumeration .1.3.6.1.4.1.3320.101.10.6.1.1.34 |
currentAlarmUpLimitThresholdThe upper threshold of current alarm. The unit is 0.1mA. The range is 0-1310. Default is 1310.rw INTEGER .1.3.6.1.4.1.3320.101.10.6.1.1.35 |
currentAlarmUpLimitClearThresholdThe upper threshold current alarm cleared. The unit is 0.1mA. The range is 0-1310. Default is 1310.rw INTEGER .1.3.6.1.4.1.3320.101.10.6.1.1.36 |
currentAlarmUpLimitRowStatusThe row status of current upper alarm.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.3320.101.10.6.1.1.37 |
currentAlarmLowLimitEnableEnable or disable the alarm of PON low current. 1-enable, 2-disable. Default is disable.rw Enumeration .1.3.6.1.4.1.3320.101.10.6.1.1.38 |
currentAlarmLowLimitThresholdThe low threshold of current alarm. The unit is 0.1mA. The range is 0-1310. Default is 0.rw INTEGER .1.3.6.1.4.1.3320.101.10.6.1.1.39 |
currentAlarmLowLimitClearThresholdThe low threshold current alarm cleared. The unit is 0.1mA. The range is 0-1310. Default is 0.rw INTEGER .1.3.6.1.4.1.3320.101.10.6.1.1.40 |
currentAlarmLowLimitRowStatusThe row status of current low alarm.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.3320.101.10.6.1.1.41 |