Home/Catalog/MRV-IR-HDAM-MIB

MRV-IR-HDAM-MIB

AI MIB Summary

The MRV-IR-HDAM-MIB module enables SNMP-based monitoring of alarm states and fault conditions on MRV LX HDAM (High-Density Access Module) hardware. It provides specific visibility into hardware integrity, port status, and environmental alerts for these high-density access aggregation devices.

This is the MRV LX HDAM Alarm MIB module.
Main OID:
irHdamMib.1.3.6.1.4.1.33.100.4
73
Objects
Active
Status
3
Dependencies

Imported Objects

Objects

73 total
Object Name
mrvBpd
OBJECT IDENTIFIER
.1.3.6.1.4.1.33
mrvLx
OBJECT IDENTIFIER
.1.3.6.1.4.1.33.100
irHdamMibThis is the MRV LX HDAM Alarm MIB module.
MODULE-IDENTITY
.1.3.6.1.4.1.33.100.4
irHdam
OBJECT IDENTIFIER
.1.3.6.1.4.1.33.100.4.1
irHdamUnitTableA list of hdam unit entries.
SEQUENCE OF IrHdamUnitEntry
.1.3.6.1.4.1.33.100.4.1.1
irHdamUnitEntryAn hdam unit entry.
IrHdamUnitEntry
.1.3.6.1.4.1.33.100.4.1.1.1
irHdamUnitPortIndexThe port index to which this hdam unit is connected.ro
INTEGER
.1.3.6.1.4.1.33.100.4.1.1.1.1
irHdamFwVersionThe HDAM unit firmware version string.ro
DisplayString
.1.3.6.1.4.1.33.100.4.1.1.1.2
irHdamConnectStatusThe HDAM unit connection status.ro
Enumeration
.1.3.6.1.4.1.33.100.4.1.1.1.3
irHdamPowerTypeThe type of power used by the hdam device.ro
Enumeration
.1.3.6.1.4.1.33.100.4.1.1.1.4
irHdamActionThis object is used to perform an action on the HDAM unit. A read of this object always returns the value other(1). Setting this object to reset(2) causes the unit to be reset.rw
Enumeration
.1.3.6.1.4.1.33.100.4.1.1.1.5
irHdamModuleTableA list of hdam module entries.
SEQUENCE OF IrHdamModuleEntry
.1.3.6.1.4.1.33.100.4.1.2
irHdamModuleEntryAn hdam module entry.
IrHdamModuleEntry
.1.3.6.1.4.1.33.100.4.1.2.1
irHdamPortIndexThe port index to which this hdam unit is connected.ro
INTEGER
.1.3.6.1.4.1.33.100.4.1.2.1.1
irHdamSlotIndexThe slot index for this module entry.ro
INTEGER
.1.3.6.1.4.1.33.100.4.1.2.1.2
irHdamModuleTypeThe type of module in the slot.ro
IrHdamModuleType
.1.3.6.1.4.1.33.100.4.1.2.1.3
irHdamPowerSupplyTableA list of hdam power supply entries.
SEQUENCE OF IrHdamPowerSupplyEntry
.1.3.6.1.4.1.33.100.4.1.3
irHdamPowerSupplyEntryAn hdam power supply entry.
IrHdamPowerSupplyEntry
.1.3.6.1.4.1.33.100.4.1.3.1
irHdamPowerPortIndexThe index of the port to which the hdam unit is attached.ro
INTEGER
.1.3.6.1.4.1.33.100.4.1.3.1.1
irHdamPowerIndexThe index of the hdam power unit.ro
INTEGER
.1.3.6.1.4.1.33.100.4.1.3.1.2
irHdamPowerUnitPresentThis indicates if the power unit is present or not.ro
Enumeration
.1.3.6.1.4.1.33.100.4.1.3.1.3
irHdamPowerInputStatusThis indicates if the power unit is plugged into a power source.ro
Enumeration
.1.3.6.1.4.1.33.100.4.1.3.1.4
irHdamPowerOutputStatusThis indicates the status of the internal power feed to the device components.ro
Enumeration
.1.3.6.1.4.1.33.100.4.1.3.1.5
irHdamPowerStatusThe overall status of the power unit.ro
Enumeration
.1.3.6.1.4.1.33.100.4.1.3.1.6
irHdamAlarm
OBJECT IDENTIFIER
.1.3.6.1.4.1.33.100.4.2
irAlarmConfigTableA list of alarm config entries.
SEQUENCE OF IrAlarmConfigEntry
.1.3.6.1.4.1.33.100.4.2.1
irAlarmConfigEntryAn hdam alarm config entry.
IrAlarmConfigEntry
.1.3.6.1.4.1.33.100.4.2.1.1
irAlarmPortIndexThe port index on which the alarm unit is attached.ro
INTEGER
.1.3.6.1.4.1.33.100.4.2.1.1.1
irAlarmSlotIndexThe slot in the alarm unit which identifies this module.ro
INTEGER
.1.3.6.1.4.1.33.100.4.2.1.1.2
irAlarmPointIndexAn integer which uniquely identifies an alarm on this module.ro
INTEGER
.1.3.6.1.4.1.33.100.4.2.1.1.3
irAlarmNameThe name assigned to the alarm.rw
DisplayString
.1.3.6.1.4.1.33.100.4.2.1.1.4
irAlarmContactStateThe current state of the alarm contacts.ro
IrContactState
.1.3.6.1.4.1.33.100.4.2.1.1.5
irAlarmContactFaultStateThe contact state (open or closed) which indicates the fault condition. If the value of this object and irAlarmContactState is the same, then the alarm has been triggered.rw
IrContactState
.1.3.6.1.4.1.33.100.4.2.1.1.6
irAlarmDebounceIntervalThe number of seconds the alarm must be in the fault state before it is considered valid.rw
INTEGER
.1.3.6.1.4.1.33.100.4.2.1.1.7
irAlarmAudibleStatusThis indicates whether the audible alarm on the unit will sound when this alarm is generated.rw
Enumeration
.1.3.6.1.4.1.33.100.4.2.1.1.8
irAlarmTrapStatusThis indicates whether an snmp trap will be generated when this alarm is generated.rw
Enumeration
.1.3.6.1.4.1.33.100.4.2.1.1.9
irAlarmTrapSeverityThe trap severity assigned to this alarm. This value will be sent when an alarm fires and an snmp trap is generated.rw
TrapSeverity
.1.3.6.1.4.1.33.100.4.2.1.1.10
irAlarmCountThe number of times the alarm has been generated since the unit was started.ro
Counter32
.1.3.6.1.4.1.33.100.4.2.1.1.11
irAlarmTimestampA timestamp string indicating the time the last alarm was generated. A null string indicates that the alarm has not been generated.ro
DisplayString
.1.3.6.1.4.1.33.100.4.2.1.1.12
irAlarmDescriptionA user configurable alarm description string.rw
DisplayString
.1.3.6.1.4.1.33.100.4.2.1.1.13
irHdamControl
OBJECT IDENTIFIER
.1.3.6.1.4.1.33.100.4.3
irControlConfigTableA list of control config entries.
SEQUENCE OF IrControlConfigEntry
.1.3.6.1.4.1.33.100.4.3.1
irControlConfigEntryA control config entry.
IrControlConfigEntry
.1.3.6.1.4.1.33.100.4.3.1.1
irControlPortIndexThe port index on which the control unit is attached.ro
INTEGER
.1.3.6.1.4.1.33.100.4.3.1.1.1
irControlSlotIndexThe slot in the control unit which identifies this module.ro
INTEGER
.1.3.6.1.4.1.33.100.4.3.1.1.2
irControlPointIndexAn integer which uniquely identifies a control on this module.ro
INTEGER
.1.3.6.1.4.1.33.100.4.3.1.1.3
irControlNameThe name assigned to the control.rw
DisplayString
.1.3.6.1.4.1.33.100.4.3.1.1.4
irControlStateThe current value of the control state.rw
IrContactState
.1.3.6.1.4.1.33.100.4.3.1.1.5
irControlActiveStateThe value of the control state that activates the attached device.rw
IrContactState
.1.3.6.1.4.1.33.100.4.3.1.1.6
irControlDescriptionA user configurable control description string.rw
DisplayString
.1.3.6.1.4.1.33.100.4.3.1.1.7
irHdamAnalog
OBJECT IDENTIFIER
.1.3.6.1.4.1.33.100.4.4
irAnalogConfigTableA list of analog loop config entries.
SEQUENCE OF IrAnalogConfigEntry
.1.3.6.1.4.1.33.100.4.4.1
irAnalogConfigEntryAn analog loop config entry.
IrAnalogConfigEntry
.1.3.6.1.4.1.33.100.4.4.1.1
irAnalogPortIndexThe port index on which the analog unit is attached.ro
INTEGER
.1.3.6.1.4.1.33.100.4.4.1.1.1
irAnalogSlotIndexThe slot in the analog unit which identifies this module.ro
INTEGER
.1.3.6.1.4.1.33.100.4.4.1.1.2
irAnalogPointIndexAn integer which uniquely identifies an analog point on this module.ro
INTEGER
.1.3.6.1.4.1.33.100.4.4.1.1.3
irAnalogNameThe name assigned to the analog.rw
DisplayString
.1.3.6.1.4.1.33.100.4.4.1.1.4
irAnalogDescriptionA user configurable analog description string.rw
DisplayString
.1.3.6.1.4.1.33.100.4.4.1.1.5
irAnalogStatusThe status of the analog point.rw
IrAnalogStatus
.1.3.6.1.4.1.33.100.4.4.1.1.6
irAnalogValueThe current analog sensor reading in milliAmps.ro
DisplayString
.1.3.6.1.4.1.33.100.4.4.1.1.7
irAnalogCalValueThe current analog sensor calibrated value.ro
DisplayString
.1.3.6.1.4.1.33.100.4.4.1.1.8
irAnalogCalMinValueThe calibration value assigned to the minimum sensor reading.rw
DisplayString
.1.3.6.1.4.1.33.100.4.4.1.1.9
irAnalogCalMaxValueThe calibration value assigned to the maximum analog sensor reading.rw
DisplayString
.1.3.6.1.4.1.33.100.4.4.1.1.10
irAnalogCalMarginThe calibration margin value. This will be added to the calibrated analog sensor value.rw
DisplayString
.1.3.6.1.4.1.33.100.4.4.1.1.11
irAnalogCalUnitsA user defined string describing the calibrated units for the analog sensor.rw
DisplayString
.1.3.6.1.4.1.33.100.4.4.1.1.12
irAnalogThresholdHighThe analog sensor high threshold value. A value of -0 indicates threshold is not configured.rw
DisplayString
.1.3.6.1.4.1.33.100.4.4.1.1.13
irAnalogThresholdLowThe analog sensor low threshold value. A value of -0 indicates threshold is not configured.rw
DisplayString
.1.3.6.1.4.1.33.100.4.4.1.1.14
irAnalogThresholdSeverityThe severity value of the analog sensor assigned to the low threshold. This value will be sent in the threshold trap.rw
TrapSeverity
.1.3.6.1.4.1.33.100.4.4.1.1.15
irAnalogThresholdHysteresisAfter crossing a threshold, the delta by which the caliberated value must drop within the normal range before the alarm condition is cleared (i.e. a cleared alarm is generated).rw
DisplayString
.1.3.6.1.4.1.33.100.4.4.1.1.16
irAnalogThresholdHighAlarmCountThe number of times the analog sensor high threshold has been crossed since the unit was started.ro
Counter32
.1.3.6.1.4.1.33.100.4.4.1.1.17
irAnalogThresholdLowAlarmCountThe number of times the analog sensor low threshold has been crossed since the unit was started.ro
Counter32
.1.3.6.1.4.1.33.100.4.4.1.1.18
irAnalogThresholdHighTimestampA timestamp string indicating the time the analog sensor last crossed the high threshold. A null string indicates that the alarm has not been crossed.ro
DisplayString
.1.3.6.1.4.1.33.100.4.4.1.1.19
irAnalogThresholdLowTimestampA timestamp string indicating the time the analog sensor last crossed the low threshold. A null string indicates that the alarm has not been crossed.ro
DisplayString
.1.3.6.1.4.1.33.100.4.4.1.1.20
MRV-IR-HDAM-MIB - SNMP MIB Reference | MIBs Explorer