MICOM-SYS-MIB
Detailed view of the defined objects, syntax rules, and hierarchical paths.
Imported Objects
Objects
156 total| Object Name |
|---|
micom-system OBJECT IDENTIFIER .micom-oscar.1 |
RFC1155-SMI Unknown .micom-oscar.1 |
mcmSysMainPowerSupplyFailureNAME = ;
DESC = System TRAP message: indication of Power Supply \
failure.\
Severity Level: CRITICAL.;
HELP = Power Supply Jumper may not be set properly.\
Please contact the System Administrator, or\
field Personnel.; TRAP-TYPE .micom-oscar.1.0.1 |
mcmSysChassisFanFailureNAME = ;
DESC = System TRAP message: indication of a chassis \
FAN failure on the access device.\
Severity Level: MINOR.;
HELP = Fan is not running. Please contact the System\
administrator, or Filed Personnel.; TRAP-TYPE .micom-oscar.1.0.2 |
mcmSysSystemResetNAME = ;
DESC = System TRAP message: indication of system Reset \
(warm start).\
Severity Level: INFORMATIVE.;
HELP = A system reset has occured. If normal \
operation did not resume after the Reset, Please \
contact the System Administrator, or Field \
Personnel.; TRAP-TYPE .micom-oscar.1.0.3 |
mcmSysBatteryLowNAME = ;
DESC = System TRAP message: Indication of Battery Low.\
Severity Level: MINOR.;
HELP = The access device is experiencing a Battery \
Low condition. Please contact the System \
Administrator or Field Personnel.; TRAP-TYPE .micom-oscar.1.0.4 |
mcmSysConfigChangedNAME = ;
DESC = An indication of configuration change in \
the access device.\
Severity Level: MAJOR.;
HELP = Configuration has changed in access device. Please \
consult the System Administrator, or Field Personnel \
if the configuration has affected your applications.; TRAP-TYPE .micom-oscar.1.0.5 |
mcmSysCPUUtilExceededNAME = ;
DESC = System TRAP message: Indication of CPU Utilization \
exceeded for configured threshold.\
Severity Level: MAJOR.;
HELP = The access device has exceeded its configured threshold \
value for CPU Utilization.
This value can be changed using set sys traps cpu 1 - 100.\
Or Consult your system Administrator, or field Personnel if \
this value needs to be changed.; TRAP-TYPE .micom-oscar.1.0.6 |
mcmSysBandwidthUtilExceededNAME = ;
DESC = System TRAP message: Indication of Bandwidth \
Utilization exceeded for configured threshold.\
Severity Level: MAJOR.;
HELP = The access device has exceeded its Configured \
threshold value for its bandwidth utilization. \
This value can be changed using set sys traps \
bandwidth 1-100 or Consult your system \
Administrator, or Field Personnel if this value needs \
to be changed.; TRAP-TYPE .micom-oscar.1.0.7 |
mcmSysRAMUtilExceededNAME = ;
DESC = System TRAP message: Indication of RAM \
Utilization exceeded for configured threshold.\
Severity Level: MAJOR.;
HELP = It is an indication of surpassing the configured \
value for RAM utilization. This value can be changed
using set sys traps ram 1-100 or Consult your system \
administrator, or Field Personnel if this value needs \
to be changed.; TRAP-TYPE .micom-oscar.1.0.8 |
mcmSysRollbackEnabledNAME = ;
DESC = System TRAP message: Indication of System \
Rollback Feature enabled.\
Severity Level: INFORMATIVE.;
HELP = This is an indication of the Rollback feature \
being enabled. Please disable this feature if \
it is not desired, or consult your System Admin.\
or Field Personnel.; TRAP-TYPE .micom-oscar.1.0.9 |
mcmSysRollbackDisabledNAME = ;
DESC = System TRAP message: Indication of System \
Rollback Feature disabled.\
Severity Level: INFORMATIVE.;
HELP = This is an indication of the Rollback feature \
being disabled. Please enable this feature if \
it is required. Otherwise, consult your system \
admin. or Field Personnel.; TRAP-TYPE .micom-oscar.1.0.10 |
mcmSysRollbackArmedNAME = ;
DESC = System TRAP message: Indication of System \
Rollback Feature armed, resulting from User \
committing/activating Code/Config Bank for \
next reset.\
Severity Level: INFORMATIVE.;
HELP = This is an indication of user committing a new \
code bank/Config Bank after the access device \
is reset the next time around. If this \
condition is not needed, consult your System \
Admin. or Field personnel.; TRAP-TYPE .micom-oscar.1.0.11 |
mcmSysRollbackDisarmedNAME = ;
DESC = System TRAP message: Indication of System \
Rollback Feature confirmed for this session.\
Severity Level: INFORMATIVE.;
HELP = This is a condition of disarming previously \
committed Code Bank/config Bank that was going \
to occur after a reset. If it is not desirable, \
reverse the condition., ; TRAP-TYPE .micom-oscar.1.0.12 |
sys-configuration OBJECT IDENTIFIER .micom-oscar.1.1 |
mcmSysHWTypeGroup OBJECT IDENTIFIER .micom-oscar.1.1.1 |
mcmSysHWTypeModelTypeNAME = ;
DESC = **NOTE: THIS OBJECT HAS BEEN \
DEPRECATED. Its functionality \
has been replaced by the \
mcmSysHWTypeCPUType object \
located below in this group.**\
\
The model name/type of the \
access device.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;rodeprecated DisplayString .micom-oscar.1.1.1.1 |
mcmSysHWTypeRevisionLevelNAME = ;
DESC = The revision level of the \
access device.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;ro INTEGER .micom-oscar.1.1.1.2 |
mcmSysHWTypeManufRevDateNAME = ;
DESC = The manufacture/revision date \
of the access device .;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;ro DisplayString .micom-oscar.1.1.1.3 |
mcmSysHWTypeSerialNumberNAME = ;
DESC = The serial number of \
the access device..;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;ro DisplayString .micom-oscar.1.1.1.4 |
mcmSysHWTypeModuleIDNAME = ;
DESC = The module ID of the access \
device.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;ro INTEGER .micom-oscar.1.1.1.5 |
mcmSysHWTypeMACAddressNAME = ;
DESC = The base MAC address assigned \
to the access device.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;ro OCTET STRING .micom-oscar.1.1.1.6 |
mcmSysHWTypeCPUTypeNAME = ;
DESC = Indicates the CPU type for this \
access device;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;ro DisplayString .micom-oscar.1.1.1.7 |
mcmSysHWTypeGenCfgTypeNAME = ;
DESC = Indicates the model type for this \
access device.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;ro Enumeration .micom-oscar.1.1.1.8 |
mcmSysCfgGroup OBJECT IDENTIFIER .micom-oscar.1.1.2 |
mcmSysCfgCPUConfigurationNAME = ;
DESC = The CPU configuration for this
access device.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;ro Enumeration .micom-oscar.1.1.2.1 |
mcmSysCfgPrimaryWANPortNAME = ;
DESC = Indicates the presence of the \
Primary WAN port.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;ro Enumeration .micom-oscar.1.1.2.2 |
mcmSysCfgPrimaryWANPortPhyMediaNAME = ;
DESC = Indicates the physical media
of Primary WAN port.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;ro Enumeration .micom-oscar.1.1.2.3 |
mcmSysCfgDCESerialPortPhyMediaNAME = ;
DESC = Indicates the detected DCE \
serial port on the access \
device.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;ro Enumeration .micom-oscar.1.1.2.4 |
mcmSysCfgQUICCExpansionModule1NAME = ;
DESC = QUICC Expansion module detected.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;ro Enumeration .micom-oscar.1.1.2.5 |
mcmSysCfgQUICCExpansionModule2NAME = ;
DESC = QUICC Expansion module-2 is detected.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;ro Enumeration .micom-oscar.1.1.2.6 |
mcmSysCfgFeatureRTCBatteryStatusNAME = ;
DESC = TimeOfDay/SRAM module detected.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;ro Enumeration .micom-oscar.1.1.2.7 |
mcmSysCfgDRAMSizeNAME = ;
DESC = Total installed DRAM memory size in megabytes.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;ro Enumeration .micom-oscar.1.1.2.8 |
mcmSysCfgFlashMemorySizeNAME = ;
DESC = Total installed Flash memory size in megabytes.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;ro Enumeration .micom-oscar.1.1.2.9 |
mcmSysLimTableNAME = ;
DESC = Table to view an individual Logical \
Interface Modules(LIM) on the access \
device.;
HELP = Table to view the hardware \
CAPABILITIES = NET_CFG, VPN_DISP; SEQUENCE OF McmSysLimEntry .micom-oscar.1.1.3 |
mcmSysLimEntryNAME = ;
DESC = Entry pertaining to a specific logical module.;
HELP = This includes the Name, Part number, and rev. level.;
CAPABILITIES = ; McmSysLimEntry .micom-oscar.1.1.3.1 |
mcmSysLimModuleAddressNAME = ;
DESC = lim (logical interface module) identifies \
the address of the module within the unit;
HELP = ;
CAPABILITIES = ;ro Enumeration .micom-oscar.1.1.3.1.1 |
mcmSysLimModuleNameNAME = ;
DESC = Displays the name of the module \
in the specific location;
NOTE : this object was previously named \
mcmSysCardModuleName.;
HELP = ;
CAPABILITIES = ;ro DisplayString .micom-oscar.1.1.3.1.2 |
mcmSysLimPcbPartNumberNAME = ;
DESC = Displays the part number of the module in \
the specific location;
HELP = ;
CAPABILITIES = ;ro DisplayString .micom-oscar.1.1.3.1.3 |
mcmSysLimPcbReleaseNAME = ;
DESC = Displays the release level of the module in \
the specific location.;
HELP = ;
CAPABILITIES = ;ro DisplayString .micom-oscar.1.1.3.1.4 |
mcmSysLimSerialNumberNAME = ;
DESC = Displays the serial number of the module in \
the specific location.;
HELP = ;
CAPABILITIES = ;ro DisplayString .micom-oscar.1.1.3.1.5 |
mcmSysLimMfgDateNAME = ;
DESC = Displays the manufacturing date of the module in \
the specific location.;
HELP = ;
CAPABILITIES = ;ro DisplayString .micom-oscar.1.1.3.1.6 |
mcmSysChassisGroup OBJECT IDENTIFIER .micom-oscar.1.1.4 |
mcmSysChassisNumberOfModulesNAME = ;
DESC = Chassis style: number of modules.;
NOTE : this object was previously named \
mcmSysChassisNumberOfSlots.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;ro Enumeration .micom-oscar.1.1.4.1 |
mcmSysChassisCoolingFanNAME = ;
DESC =Chassis cooling fan status.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;ro Enumeration .micom-oscar.1.1.4.2 |
mcmSysChassisPowerSupplyTypeNAME = ;
DESC = Specifies the type of power supply \
based on type of voltage;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;ro Enumeration .micom-oscar.1.1.4.3 |
mcmSysChassisPowerSupplyStatusNAME = ;
DESC = Fault indicates that at least one \
power supply module is down;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;ro Enumeration .micom-oscar.1.1.4.4 |
mcmSysChassisPowerSupplyModuleCountNAME = ;
DESC = Specifies the number of power \
supply modules installed;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;ro INTEGER .micom-oscar.1.1.4.5 |
mcmSysChassisPowerSupplyRedundantNAME = ;
DESC = Indicates whether there are \
redundant power supply modules;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;ro Enumeration .micom-oscar.1.1.4.6 |
mcmSysTimeOfDayGroup OBJECT IDENTIFIER .micom-oscar.1.1.5 |
mcmSysTimeOfDay OBJECT IDENTIFIER .micom-oscar.1.1.5.1 |
mcmSysTimeOfDaySecNAME = ;
DESC = System Time of day in seconds.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;rw INTEGER .micom-oscar.1.1.5.1.1 |
mcmSysTimeOfDayMinNAME = ;
DESC = System Time of day in minutes.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;rw INTEGER .micom-oscar.1.1.5.1.2 |
mcmSysTimeOfDayHourNAME = ;
DESC = System Time of day in hours.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;rw INTEGER .micom-oscar.1.1.5.1.3 |
mcmSysTimeOfDayDayNAME = ;
DESC = System Time of day, the Day.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;rw Enumeration .micom-oscar.1.1.5.1.4 |
mcmSysTimeOfDayDateNAME = ;
DESC = System Time of day. The date.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;rw INTEGER .micom-oscar.1.1.5.1.5 |
mcmSysTimeOfDayMonthNAME = ;
DESC = System Time of day. The Month.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;rw INTEGER .micom-oscar.1.1.5.1.6 |
mcmSysTimeOfDayYearNAME = ;
DESC = System Time of day. The Year.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;rw INTEGER .micom-oscar.1.1.5.1.7 |
mcmSysAsciiTimeOfDayNAME = ;
DESC = This object will give the ascii version of \
the time of day. This would be the same time \
as reflected by all the other objects of \
this group put togther;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;ro DisplayString .micom-oscar.1.1.5.2 |
mcmSysFirmwareGroup OBJECT IDENTIFIER .micom-oscar.1.1.6 |
mcmSysOperationalTypeNAME = ;
DESC = Network Operational mode of this \
access device.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;rw Enumeration .micom-oscar.1.1.6.1 |
mcmSysFirmwareConfigCommitBankNAME = ;
DESC = The Default Confi. Image (global).;
HELP = Committed Config. Image Bank.;
CAPABILITIES = NET_CFG, VPN_DISP;rw Enumeration .micom-oscar.1.1.6.2 |
mcmSysFirmwareConfigSaveBankNAME = ;
DESC = Default Software Image Bank.;
HELP = Committed Code Image (global).;
CAPABILITIES = NET_CFG, VPN_DISP;rw Enumeration .micom-oscar.1.1.6.3 |
mcmSysFirmwareConfigActiveBankNAME = ;
DESC = The active Configuration Image Bank.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;rw Enumeration .micom-oscar.1.1.6.4 |
mcmSysFirmwareConfigReadBankNAME = ;
DESC = The Bank that the Configuration Read from.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;ro Enumeration .micom-oscar.1.1.6.5 |
mcmSysFirmwareCodeReadBankNAME = ;
DESC =The Bank that the Code Read from.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;ro Enumeration .micom-oscar.1.1.6.6 |
mcmSysFirmwareCodeCommitBankNAME = ;
DESC =The Bank that the Code is committed from.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;rw Enumeration .micom-oscar.1.1.6.7 |
mcmSysFirmwareVersionNAME = ;
DESC = The Code Version that this access \
device is running on.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;ro DisplayString .micom-oscar.1.1.6.8 |
mcmSysFirmwareConfigVersionNAME = ;
DESC = The Configuration Version that this \
access device is running on.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;ro DisplayString .micom-oscar.1.1.6.9 |
mcmSysFirmwareImageTableNAME = ;
DESC = The Firmware Image Table contains \
information about the Code Image.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP; SEQUENCE OF McmSysFirmwareImageEntry .micom-oscar.1.1.7 |
mcmSysFirmwareImageEntryNAME = ;
DESC = The entry that pertains to Code Image.;
HELP = ;
CAPABILITIES = ; McmSysFirmwareImageEntry .micom-oscar.1.1.7.1 |
mcmSysFirmwareImageIndexNAME = ;
DESC = The Index value for a specific Image.;
HELP = ;
CAPABILITIES = ;ro INTEGER .micom-oscar.1.1.7.1.1 |
mcmSysFirmwareImageBankNAME = ;
DESC = The Specific ImageBank that holds the Code \
Image or Config Image.;
HELP = ;
CAPABILITIES = ;ro Enumeration .micom-oscar.1.1.7.1.2 |
mcmSysFirmwareImageSoftwareNAME = ;
DESC = This indicates that the specific Software \
is a boot Code, Image Code or a Config Code.;
HELP = ;
CAPABILITIES = ;ro Enumeration .micom-oscar.1.1.7.1.3 |
mcmSysFirmwareImageFilenameNAME = ;
DESC =This indicates the File name of the Firmware.;
HELP = ;
CAPABILITIES = ;ro DisplayString .micom-oscar.1.1.7.1.4 |
mcmSysFirmwareImageRevisionNAME = ;
DESC = This indicates the Revision level of the \
specific Firmware.;
HELP = ;
CAPABILITIES = ;ro DisplayString .micom-oscar.1.1.7.1.5 |
mcmSysFirmwareImageSizeNAME = ;
DESC = This indicates the size of the Firmware in bytes.;
HELP = ;
CAPABILITIES = ;ro INTEGER .micom-oscar.1.1.7.1.6 |
mcmSysFirmwareImageCommitStatusNAME = ;
DESC = This indicates the Firmware Image Commit Status.;
HELP = ;
CAPABILITIES = ;ro Enumeration .micom-oscar.1.1.7.1.7 |
mcmSysFirmwareImageBurnCountNAME = ;
DESC = This indicates the global burn count.;
HELP = ;
CAPABILITIES = ;ro Counter .micom-oscar.1.1.7.1.8 |
mcmSysSmartCfgGroup OBJECT IDENTIFIER .micom-oscar.1.1.8 |
mcmSysSmartCfgActionNAME = ;
DESC = Directs system to update secondary (Flash) storage \
by saving present configuration. Or directs discard \
of present re-configures.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;rw Enumeration .micom-oscar.1.1.8.1 |
mcmSysSmartCfgStatusNAME = ;
DESC = Indicates if system is currently being \
re-configured.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;ro Enumeration .micom-oscar.1.1.8.2 |
mcmSysCommunityStringTableNAME = ;
DESC = The System Community String Table.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_NONE; SEQUENCE OF McmSysCommunityStringEntry .micom-oscar.1.1.9 |
mcmSysCommunityStringEntryNAME = ;
DESC = Entry that pertains to the Community \
string.;
HELP = ;
CAPABILITIES = ; McmSysCommunityStringEntry .micom-oscar.1.1.9.1 |
mcmSysCommunityStringIndexNAME = ;
DESC = The Index value for each Community Strings.;
HELP = ;
CAPABILITIES = ;rw Enumeration .micom-oscar.1.1.9.1.1 |
mcmSysCommunityStringCommunityNAME = ;
DESC = Community String used as access password.;
HELP = ;
CAPABILITIES = ;rw DisplayString .micom-oscar.1.1.9.1.2 |
mcmSysValidateCommunityGroup OBJECT IDENTIFIER .micom-oscar.1.1.10 |
mcmSysValidateCommunityNAME = ;
DESC = This parameter contains the password \
obtained by the command line user interface.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;rw DisplayString .micom-oscar.1.1.10.1 |
mcmSysLastCommunityPriviledgeLevelNAME = ;
DESC = This parameter contains the priviledge \
level from the last valid password.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;ro Enumeration .micom-oscar.1.1.10.2 |
mcmSysConsolePortGroup OBJECT IDENTIFIER .micom-oscar.1.1.11 |
mcmSysConsolePortBaudRateNAME = ;
DESC = Set Console (and Debugger) Speed;
HELP = Set Console Speed;
CAPABILITIES = NET_CFG, VPN_DISP;rw Enumeration .micom-oscar.1.1.11.1 |
mcmSysConsolePortStopBitsNAME = ;
DESC = Set Console number of stop bits;
HELP = Set Console number of stop bits;
CAPABILITIES = NET_CFG, VPN_DISP;rw INTEGER .micom-oscar.1.1.11.2 |
mcmSysConsolePortDataBitsNAME = ;
DESC = Set Console number of Data bits (excluding start, \
stop and parity bits);
HELP = Set Console number of Data bits (excluding start, \
stop and parity bits);
CAPABILITIES = NET_CFG, VPN_DISP;rw INTEGER .micom-oscar.1.1.11.3 |
mcmSysConsolePortParityNAME = ;
DESC = Set Console parity bit;
HELP = Set Console parity bit;
CAPABILITIES = NET_CFG, VPN_DISP;rw Enumeration .micom-oscar.1.1.11.4 |
mcmSysCommitTrackingGroup OBJECT IDENTIFIER .micom-oscar.1.1.12 |
mcmSysCommitTrackingCounterNAME = ;
DESC = The Counter that pertains to the Commit Tracking.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_NONE;ro Counter .micom-oscar.1.1.12.1 |
mcmSysCommitTrackingSrcIPAddressOfLastCommitNAME = ;
DESC = The IP address of the SNMP manager that issued \
the last successful SET operation.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_NONE;ro IpAddress .micom-oscar.1.1.12.2 |
mcmSysCommitTrackingCommunityOfLastCommitNAME = ;
DESC = The community of the last successful SET.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_NONE;ro DisplayString (SNMPv2-TC) .micom-oscar.1.1.12.3 |
mcmSysCommitTrackingTimeOfLastCommitNAME = ;
DESC = The system uptime in ticks when the last \
SET was serviced.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_NONE;ro TimeTicks (SNMPv2-SMI) .micom-oscar.1.1.12.4 |
mcmSysIfExtTableNAME = ;
DESC = The Interface table that contains \
information about IfExtension in this \
access device.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP; SEQUENCE OF McmSysIfExtEntry .micom-oscar.1.1.13 |
mcmSysIfExtEntryNAME = ;
DESC = The specific Entry that pertains to \
IfExt in this access device.;
HELP = ;
CAPABILITIES = ; McmSysIfExtEntry .micom-oscar.1.1.13.1 |
mcmSysIfExtIfIndexNAME = ;
DESC = The Index value of the specifc entry.;
HELP = ;
CAPABILITIES = ;ro INTEGER .micom-oscar.1.1.13.1.1 |
mcmSysIfExtNameNAME = ;
DESC = The Name of the specific IfExt entry.;
HELP = ;
CAPABILITIES = ;ro DisplayString .micom-oscar.1.1.13.1.2 |
mcmSysIfExtTypeNAME = ;
DESC = The values of this field are kept \
the same as the values for the \
ifExtType defined in \
the extension to MIB II (RFC1573);
HELP = ;
CAPABILITIES = ;ro Enumeration .micom-oscar.1.1.13.1.3 |
mcmSysIfExtLinkUpDownTrapEnableNAME = ;
DESC = This indicates if the LinkUpDownTrap \
is enabled or not.;
HELP = ;
CAPABILITIES = ;rw Enumeration .micom-oscar.1.1.13.1.4 |
mcmSysIfExtConnectorPresentNAME = ;
DESC = This indicates if the IfExt entry \
has a phisical connector present.;
HELP = ;
CAPABILITIES = ;ro Enumeration .micom-oscar.1.1.13.1.5 |
mcmSysIfExtPersistenceTypeNAME = ;
DESC = This indicates if the Persistence Type \
is volatile or non-volatile.;
HELP = ;
CAPABILITIES = ;ro Enumeration .micom-oscar.1.1.13.1.6 |
mcmSysIfExtStateNAME = ;
DESC = This indicates that if the IfExt entry \
is configured or not.;
HELP = ;
CAPABILITIES = ;ro Enumeration .micom-oscar.1.1.13.1.7 |
mcmSysIfExtPPANAME = ;
DESC = The PPA of the port;
HELP = ;
CAPABILITIES = ;ro INTEGER .micom-oscar.1.1.13.1.8 |
mcmSysIfExtModuleNAME = ;
DESC = The logical interface module address \
of this interface \
NOTE : this object was previously named \
mcmSysIfExtSlot.;
HELP = ;
CAPABILITIES = ;ro Enumeration .micom-oscar.1.1.13.1.9 |
mcmSysIfExtChannelNAME = ;
DESC = The channel number of this interface... \
FR DCE: N/A, WAN Driver: SCC number, \
WAN Connector: corresponding SCC number;
HELP = ;
CAPABILITIES = ;ro INTEGER .micom-oscar.1.1.13.1.10 |
mcmSysIfExtPPADeviceTypeNAME = ;
DESC = The PPA device type of this interface.;
HELP = ;
CAPABILITIES = ;ro Enumeration .micom-oscar.1.1.13.1.11 |
mcmSysRollbackGroup OBJECT IDENTIFIER .micom-oscar.1.1.14 |
mcmSysRollbackFeatureNAME = ;
DESC = This indicates if the RollBack feature is \
enabled or disabled.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;rw Enumeration .micom-oscar.1.1.14.1 |
mcmSysRollbackStatusNAME = ;
DESC = This indicates whether Confirm system \
Rollback is required or not. Or will \
Confirm at the next reset.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;ro Enumeration .micom-oscar.1.1.14.2 |
mcmSysRollbackConfirmNAME = ;
DESC = This confirms that previous System Configuration \
or Code bank changes are accepted and that the \
System is NOT to timeout, reset and go back to
previous Config or Code bank.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;rw Enumeration .micom-oscar.1.1.14.3 |
nvmSysIfExtTableNAME = ;
DESC = The Interface table that contains \
information about IfExtension in this \
access device.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP; SEQUENCE OF NvmSysIfExtEntry .micom-oscar.1.1.15 |
nvmSysIfExtEntryNAME = ;
DESC = The specific Entry that pertains to \
IfExt in this access device.;
HELP = ;
CAPABILITIES = ; NvmSysIfExtEntry .micom-oscar.1.1.15.1 |
nvmSysIfExtIfIndexNAME = ;
DESC = The Index value of the specifc entry.;
HELP = ;
CAPABILITIES = ;ro INTEGER .micom-oscar.1.1.15.1.1 |
nvmSysIfExtNameNAME = ;
DESC = The Name of the specific IfExt entry.;
HELP = ;
CAPABILITIES = ;ro DisplayString .micom-oscar.1.1.15.1.2 |
nvmSysIfExtTypeNAME = ;
DESC = The values of this field are kept \
the same as the values for the \
ifExtType defined in \
the extension to MIB II (RFC1573);
HELP = ;
CAPABILITIES = ;ro Enumeration .micom-oscar.1.1.15.1.3 |
nvmSysIfExtLinkUpDownTrapEnableNAME = ;
DESC = This indicates if the LinkUpDownTrap \
is enabled or not.;
HELP = ;
CAPABILITIES = ;ro Enumeration .micom-oscar.1.1.15.1.4 |
nvmSysIfExtConnectorPresentNAME = ;
DESC = This indicates if the IfExt entry \
has a phisical connector present.;
HELP = ;
CAPABILITIES = ;ro Enumeration .micom-oscar.1.1.15.1.5 |
nvmSysIfExtPersistenceTypeNAME = ;
DESC = This indicates if the Persistence Type \
is volatile or non-volatile.;
HELP = ;
CAPABILITIES = ;ro Enumeration .micom-oscar.1.1.15.1.6 |
nvmSysIfExtStateNAME = ;
DESC = This indicates that if the IfExt entry \
is configured or not.;
HELP = ;
CAPABILITIES = ;ro Enumeration .micom-oscar.1.1.15.1.7 |
nvmSysIfExtPPANAME = ;
DESC = The PPA of the port;
HELP = ;
CAPABILITIES = ;ro INTEGER .micom-oscar.1.1.15.1.8 |
nvmSysIfExtModuleNAME = ;
DESC = The logical interface module address \
of this interface \
NOTE : this object was previously named \
nvmSysIfExtSlot.;
HELP = ;
CAPABILITIES = ;ro Enumeration .micom-oscar.1.1.15.1.9 |
nvmSysIfExtChannelNAME = ;
DESC = The channel number of this interface... \
FR DCE: N/A, WAN Driver: SCC number, \
WAN Connector: corresponding SCC number;
HELP = ;
CAPABILITIES = ;ro INTEGER .micom-oscar.1.1.15.1.10 |
nvmSysIfExtPPADeviceTypeNAME = ;
DESC = The PPA device type of this interface.;
HELP = ;
CAPABILITIES = ;ro Enumeration .micom-oscar.1.1.15.1.11 |
mcmSysPhysTableNAME = ;
DESC = Table to map physical cards to \
Logical Interface Modules (LIM) on \
the access device
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP; SEQUENCE OF McmSysPhysEntry .micom-oscar.1.1.16 |
mcmSysPhysEntryNAME = ;
DESC = Entry pertaining to a specific physical module.;
HELP = ;
CAPABILITIES = ; McmSysPhysEntry .micom-oscar.1.1.16.1 |
mcmSysPhysModuleAddressNAME = ;
DESC = The value of this object identifies \
the physical slot address of the module \
within the unit;
HELP = ;
CAPABILITIES = ;ro INTEGER .micom-oscar.1.1.16.1.1 |
mcmSysLogModuleAddressNAME = ;
DESC = The value of this object identifies \
the logical interface module (lim) address;
HELP = ;
CAPABILITIES = ;ro Enumeration .micom-oscar.1.1.16.1.2 |
sys-control OBJECT IDENTIFIER .micom-oscar.1.2 |
mcmSysResetGroup OBJECT IDENTIFIER .micom-oscar.1.2.1 |
mcmSysResetActionNAME = ;
DESC = Reset Unit, restart the CPU only, warm start \
or factory default (cold start).;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;rw Enumeration .micom-oscar.1.2.1.1 |
mcmSysRestartReasonNAME = ;
DESC = Reset Restart Reason Codes;
HELP = Reason Code for last Reset;
CAPABILITIES = NET_CFG, VPN_DISP;ro Enumeration .micom-oscar.1.2.1.2 |
mcmSysTimeOfLastResetNAME = ;
DESC = This object will indicate the time of \
when the access device was last reset.
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;ro DisplayString .micom-oscar.1.2.1.3 |
mcmSysCfgLockGroup OBJECT IDENTIFIER .micom-oscar.1.2.2 |
mcmSysCfgLockNAME = ;
DESC = Indicates if system config is locked.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;rw DisplayString .micom-oscar.1.2.2.1 |
sys-statistics OBJECT IDENTIFIER .micom-oscar.1.3 |
mcmSysUtilGroup OBJECT IDENTIFIER .micom-oscar.1.3.1 |
mcmSysCpuUtilizationNAME = ;
DESC = Indicates the CPU utilization in percent.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;ro Gauge .micom-oscar.1.3.1.1 |
mcmSysLinkTransmitBandwidthUtilizationNAME = ;
DESC = Indicates the Bandwidth Utilization in percent.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;ro Gauge .micom-oscar.1.3.1.2 |
mcmSysInternalRAMUtilizationNAME = ;
DESC = Indicates internal RAM Utilization in percent.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;ro Gauge .micom-oscar.1.3.1.3 |
mcmSysLinkReceiveBandwidthUtilizationNAME = ;
DESC = Indicates the Link Receive Bandwidth utilization.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;ro Gauge .micom-oscar.1.3.1.4 |
sys-trap OBJECT IDENTIFIER .micom-oscar.1.4 |
mcmSysTrapSubscriptionTableNAME = ;
DESC = This Table displays the System Trap \
subscription information of this \
access device.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP; SEQUENCE OF McmSysTrapSubscriptionEntry .micom-oscar.1.4.1 |
mcmSysTrapSubscriptionEntryNAME = ;
DESC = Entry that pertains to a specific TRAP.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP; McmSysTrapSubscriptionEntry .micom-oscar.1.4.1.1 |
mcmSysTrapSubscriptionIPAddressNAME = ;
DESC = IP address of the SNMP Manager subscribing Traps.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;rw IpAddress .micom-oscar.1.4.1.1.1 |
mcmSysTrapSubscriptionCommunityStringNAME = ;
DESC = Community string for this subscriber.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;rw DisplayString (SNMPv2-TC) .micom-oscar.1.4.1.1.2 |
mcmSysTrapSubscriptionActionNAME = ;
DESC = Action to take: add or delete subscriber.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;rw Enumeration .micom-oscar.1.4.1.1.3 |
mcmSysTrapThresholdGroup OBJECT IDENTIFIER .micom-oscar.1.4.2 |
mcmSysTrapCPUUtilThresholdNAME = ;
DESC = Indicates the configured threshold for \
CPU Utilization.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;rw INTEGER .micom-oscar.1.4.2.1 |
mcmSysTrapBandwidthUtilThresholdNAME = ;
DESC = Indicates the configured threshold for \
bandwidth utilization.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;rw INTEGER .micom-oscar.1.4.2.2 |
mcmSysTrapRAMUtilThresholdNAME = ;
DESC = Indicates the configured threshold for \
RAM utilization.;
HELP = ;
CAPABILITIES = NET_CFG, VPN_DISP;rw INTEGER .micom-oscar.1.4.2.3 |
More MIBs from Default
Browse all DefaultMIBs →SNMP MIB module
The AVAYA-WLAN-MIB provides SNMP-based management and monitoring capabilities for Avaya wireless LAN infrastructure, enabling the collection of performance metrics such as access point status, client association counts, signal strength, and radio interface statistics. This module facilitates the tracking of WLAN-specific events and configuration parameters to support network availability and troubleshooting within Avaya wireless deployments.
The VMWARE-NSX-MIB enables SNMP-based monitoring and management of VMware NSX-T Data Center virtual network infrastructure, exposing metrics for logical switches, routers, distributed firewalls, and overlay tunnel states. It facilitates the tracking of Layer 2 through Layer 7 service instances, including access control lists, Quality of Service policies, and virtual network topology changes within the software-defined networking environment.
Standard SNMP MIB module defining data structures for 923switch.m.
Standard SNMP MIB module defining data structures for CTATX-MIB.
SNMP MIB module