ME1200-SYNCE-MIB
Imported Objects
Objects
74 total| Object Name |
|---|
me1200SynceMibPrivate SyncE MIB. MODULE-IDENTITY .1.3.6.1.4.1.9.9.815.1.42 |
me1200SynceMibObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.815.1.42.1 |
me1200SynceCapabilities OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.815.1.42.1.1 |
me1200SynceCapabilitiesGlobal OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.815.1.42.1.1.1 |
me1200SynceCapabilitiesGlobalSourceCountThe number of SyncE sources supported by the device.ro Unsigned32 .1.3.6.1.4.1.9.9.815.1.42.1.1.1.1 |
me1200SynceConfig OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.815.1.42.1.2 |
me1200SynceConfigGlobal OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.815.1.42.1.2.1 |
me1200SynceConfigGlobalClockSelectionMode OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.815.1.42.1.2.1.1 |
me1200SynceConfigGlobalClockSelectionModeSelectionModeThe selection mode.rw ME1200synceSelectionMode .1.3.6.1.4.1.9.9.815.1.42.1.2.1.1.1 |
me1200SynceConfigGlobalClockSelectionModeSourceNominated source for manuel selection mode.rw Unsigned32 .1.3.6.1.4.1.9.9.815.1.42.1.2.1.1.2 |
me1200SynceConfigGlobalClockSelectionModeWtrTimeWTR timer value in minutes. Range is 0 to 12 minutes where 0 means that
the timer is disabled.rw Unsigned32 .1.3.6.1.4.1.9.9.815.1.42.1.2.1.1.3 |
me1200SynceConfigGlobalClockSelectionModeSsmHoldoverTx overwrite SSM used when clock controller is hold over.rw ME1200synceQualityLevel .1.3.6.1.4.1.9.9.815.1.42.1.2.1.1.4 |
me1200SynceConfigGlobalClockSelectionModeSsmFreerunTx overwrite SSM used when clock controller is free run.rw ME1200synceQualityLevel .1.3.6.1.4.1.9.9.815.1.42.1.2.1.1.5 |
me1200SynceConfigGlobalClockSelectionModeEecOptionSynchronous Ethernet Equipment Clock option.rw ME1200synceEecOption .1.3.6.1.4.1.9.9.815.1.42.1.2.1.1.6 |
me1200SynceConfigGlobalStationClocks OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.815.1.42.1.2.1.2 |
me1200SynceConfigGlobalStationClocksStationClkOutStation clock output frequency setting.rw ME1200synceFrequency .1.3.6.1.4.1.9.9.815.1.42.1.2.1.2.1 |
me1200SynceConfigGlobalStationClocksStationClkInStation clock input frequency setting.rw ME1200synceFrequency .1.3.6.1.4.1.9.9.815.1.42.1.2.1.2.2 |
me1200SynceConfigSources OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.815.1.42.1.2.2 |
me1200SynceConfigSourcesClockSourceNominationTableThis is the SyncE source nomination configuration. SEQUENCE OF ME1200SynceConfigSourcesClockSourceNominationEntry .1.3.6.1.4.1.9.9.815.1.42.1.2.2.1 |
me1200SynceConfigSourcesClockSourceNominationEntryThe sourceId index must be a value from 0 up to the number of sources
minus one. ME1200SynceConfigSourcesClockSourceNominationEntry .1.3.6.1.4.1.9.9.815.1.42.1.2.2.1.1 |
me1200SynceConfigSourcesClockSourceNominationSourceId- Integer32 .1.3.6.1.4.1.9.9.815.1.42.1.2.2.1.1.1 |
me1200SynceConfigSourcesClockSourceNominationNominatedIndicates if source is nominated.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.815.1.42.1.2.2.1.1.2 |
me1200SynceConfigSourcesClockSourceNominationNetworkPortInterface index of the norminated source.rw ME1200InterfaceIndex (ME1200-TC) .1.3.6.1.4.1.9.9.815.1.42.1.2.2.1.1.3 |
me1200SynceConfigSourcesClockSourceNominationClkInPortClock input of the norminated source.rw ME1200Unsigned8 (ME1200-TC) .1.3.6.1.4.1.9.9.815.1.42.1.2.2.1.1.4 |
me1200SynceConfigSourcesClockSourceNominationPriorityPriority of the nominated source.rw Unsigned32 .1.3.6.1.4.1.9.9.815.1.42.1.2.2.1.1.5 |
me1200SynceConfigSourcesClockSourceNominationAnegModeAutonogotiation mode auto-master-slave.rw ME1200synceAnegMode .1.3.6.1.4.1.9.9.815.1.42.1.2.2.1.1.6 |
me1200SynceConfigSourcesClockSourceNominationSsmOverwriteSSM overwrite quality.rw ME1200synceQualityLevel .1.3.6.1.4.1.9.9.815.1.42.1.2.2.1.1.7 |
me1200SynceConfigSourcesClockSourceNominationHoldoffTimeHold Off timer value in 100ms (3 - 18). Zero means no hold off.rw Unsigned32 .1.3.6.1.4.1.9.9.815.1.42.1.2.2.1.1.8 |
me1200SynceConfigPorts OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.815.1.42.1.2.3 |
me1200SynceConfigPortsPortConfigTableThis is the SyncE port configuration. SEQUENCE OF ME1200SynceConfigPortsPortConfigEntry .1.3.6.1.4.1.9.9.815.1.42.1.2.3.1 |
me1200SynceConfigPortsPortConfigEntryThe portId index must be a value from 0 up to the number of ports minus
one. ME1200SynceConfigPortsPortConfigEntry .1.3.6.1.4.1.9.9.815.1.42.1.2.3.1.1 |
me1200SynceConfigPortsPortConfigPortId- ME1200InterfaceIndex (ME1200-TC) .1.3.6.1.4.1.9.9.815.1.42.1.2.3.1.1.1 |
me1200SynceConfigPortsPortConfigSsmEnabledQuality level via SSM enabled.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.815.1.42.1.2.3.1.1.2 |
me1200SynceStatus OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.815.1.42.1.3 |
me1200SynceStatusGlobal OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.815.1.42.1.3.1 |
me1200SynceStatusGlobalClockSelectionMode OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.815.1.42.1.3.1.1 |
me1200SynceStatusGlobalClockSelectionModeClockInputThe clock source locked to when clock selector is in locked state.ro Unsigned32 .1.3.6.1.4.1.9.9.815.1.42.1.3.1.1.1 |
me1200SynceStatusGlobalClockSelectionModeSelectorStateThis is indicating the state of the clock selector.ro ME1200synceSelectorState .1.3.6.1.4.1.9.9.815.1.42.1.3.1.1.2 |
me1200SynceStatusGlobalClockSelectionModeLosxLOSXro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.815.1.42.1.3.1.1.3 |
me1200SynceStatusGlobalClockSelectionModeLolClock selector has raised the Los Of Lock alarm.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.815.1.42.1.3.1.1.4 |
me1200SynceStatusGlobalClockSelectionModeDholdClock selector has not yet calculated the holdover frequency offset to
local oscillator.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.815.1.42.1.3.1.1.5 |
me1200SynceStatusSources OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.815.1.42.1.3.2 |
me1200SynceStatusSourcesClockSourceNominationTableThis is the clock source nomination status. SEQUENCE OF ME1200SynceStatusSourcesClockSourceNominationEntry .1.3.6.1.4.1.9.9.815.1.42.1.3.2.1 |
me1200SynceStatusSourcesClockSourceNominationEntryThe sourceId index must be a value must be a value from 0 up to the
number of sources minus one. ME1200SynceStatusSourcesClockSourceNominationEntry .1.3.6.1.4.1.9.9.815.1.42.1.3.2.1.1 |
me1200SynceStatusSourcesClockSourceNominationSourceId- Integer32 .1.3.6.1.4.1.9.9.815.1.42.1.3.2.1.1.1 |
me1200SynceStatusSourcesClockSourceNominationLocsLOCSro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.815.1.42.1.3.2.1.1.2 |
me1200SynceStatusSourcesClockSourceNominationFosFOSro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.815.1.42.1.3.2.1.1.3 |
me1200SynceStatusSourcesClockSourceNominationSsmSSMro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.815.1.42.1.3.2.1.1.4 |
me1200SynceStatusSourcesClockSourceNominationWtrWTRro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.815.1.42.1.3.2.1.1.5 |
me1200SynceStatusPorts OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.815.1.42.1.3.3 |
me1200SynceStatusPortsPortStatusTableThis is the port status. SEQUENCE OF ME1200SynceStatusPortsPortStatusEntry .1.3.6.1.4.1.9.9.815.1.42.1.3.3.1 |
me1200SynceStatusPortsPortStatusEntryThe portId index must be a value must be a value from 0 up to the
number of ports minus one. ME1200SynceStatusPortsPortStatusEntry .1.3.6.1.4.1.9.9.815.1.42.1.3.3.1.1 |
me1200SynceStatusPortsPortStatusPortId- ME1200InterfaceIndex (ME1200-TC) .1.3.6.1.4.1.9.9.815.1.42.1.3.3.1.1.1 |
me1200SynceStatusPortsPortStatusSsmRxMonitoring of the received SSM QL on this port.ro ME1200synceQualityLevel .1.3.6.1.4.1.9.9.815.1.42.1.3.3.1.1.2 |
me1200SynceStatusPortsPortStatusSsmTxMonitoring of the transmitted SSM QL on this port.ro ME1200synceQualityLevel .1.3.6.1.4.1.9.9.815.1.42.1.3.3.1.1.3 |
me1200SynceStatusPortsPortStatusMasterIf PHY is in 1000BaseT Mode then this is monitoring the master/slave
mode.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.815.1.42.1.3.3.1.1.4 |
me1200SynceStatusPtp OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.815.1.42.1.3.4 |
me1200SynceStatusPtpPortStatusTableThis is the PTP port status. SEQUENCE OF ME1200SynceStatusPtpPortStatusEntry .1.3.6.1.4.1.9.9.815.1.42.1.3.4.1 |
me1200SynceStatusPtpPortStatusEntryThe sourceId index must be a value must be a value from 0 up to the
number of PTP sources minus one. ME1200SynceStatusPtpPortStatusEntry .1.3.6.1.4.1.9.9.815.1.42.1.3.4.1.1 |
me1200SynceStatusPtpPortStatusSourceId- Integer32 .1.3.6.1.4.1.9.9.815.1.42.1.3.4.1.1.1 |
me1200SynceStatusPtpPortStatusSsmRxMonitoring of the received SSM QL on this port.ro ME1200synceQualityLevel .1.3.6.1.4.1.9.9.815.1.42.1.3.4.1.1.2 |
me1200SynceStatusPtpPortStatusPtsfPTSF status for PTP source.ro ME1200syncePtsfState .1.3.6.1.4.1.9.9.815.1.42.1.3.4.1.1.3 |
me1200SynceControl OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.815.1.42.1.4 |
me1200SynceControlSources OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.815.1.42.1.4.1 |
me1200SynceControlSourcesClockSourceTableThis is the SyncE sources control structure. SEQUENCE OF ME1200SynceControlSourcesClockSourceEntry .1.3.6.1.4.1.9.9.815.1.42.1.4.1.1 |
me1200SynceControlSourcesClockSourceEntryThe sourceId index must be a value must be a value from 0 up to the
number of sources minus one. ME1200SynceControlSourcesClockSourceEntry .1.3.6.1.4.1.9.9.815.1.42.1.4.1.1.1 |
me1200SynceControlSourcesClockSourceSourceId- Integer32 .1.3.6.1.4.1.9.9.815.1.42.1.4.1.1.1.1 |
me1200SynceControlSourcesClockSourceClearWtr-rw ME1200Unsigned8 (ME1200-TC) .1.3.6.1.4.1.9.9.815.1.42.1.4.1.1.1.2 |
me1200SynceNotificationPrefix OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.815.1.42.1.5 |
me1200SynceNotification OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.815.1.42.1.5.0 |
me1200SynceNotificationClockSelectorStateChangeNotification is sent when the clock selector state is changed. NOTIFICATION-TYPE .1.3.6.1.4.1.9.9.815.1.42.1.5.0.1 |
me1200SynceMibConformance OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.815.1.42.2 |
me1200SynceMibCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.815.1.42.2.1 |
me1200SynceMibGroups OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.815.1.42.2.2 |
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-ENTITY-VENDORTYPE-OID-MIB maps Cisco-specific hardware component identifiers to the ENTITY-MIB's entPhysicalTable, enabling precise differentiation of physical device types such as line cards, power supplies, and fans within Cisco infrastructure. This mapping ensures that SNMP management systems can accurately correlate physical inventory entries with vendor-specific component definitions for accurate device discovery and monitoring.
The CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB provides SNMP-based monitoring and management of Cisco Unified Computing System (UCS) hardware components, including chassis, blades, fabric interconnects, and power supplies. It exposes critical operational metrics such as device status, port states, temperature readings, fan speeds, and power consumption data for infrastructure health assessment.
The CISCO-UNIFIED-COMPUTING-ADAPTOR-MIB enables SNMP-based monitoring and management of physical and virtual network adapter interfaces, including link status, traffic counters, error statistics, and port configuration parameters, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers.
The CISCO-UNIFIED-COMPUTING-TC-MIB module defines standard textual conventions and data type definitions required for monitoring Cisco Unified Computing System (UCS) hardware components, including server blades, fabric interconnects, and chassis resources. These definitions enable consistent interpretation of specific UCS metrics such as power supply status, fan speeds, thermal readings, and port utilization across SNMP management applications.
The CISCO-UNIFIED-COMPUTING-FABRIC-MIB enables SNMP-based monitoring and management of the Cisco UCS Fabric Interconnects and associated fabric switching infrastructure, exposing metrics for port states, link utilization, error counters, and fabric topology status. It facilitates granular visibility into the physical and logical fabric layers, including uplink/downlink interfaces, VLAN configurations, and fabric failover conditions within the unified computing environment.
The STARENT-MIB module provides SNMP management and monitoring capabilities for Cisco ASR 5000 and ASR 5500 multimedia core platforms, specifically exposing metrics related to 2G/3G/4G and WiFi subscriber sessions, inline service states, and carrier-class high-availability status.