Home/Catalog/ME1200-PTP-MIB

ME1200-PTP-MIB

Private PTP MIB.
Main OID:
me1200PtpMib.1.3.6.1.4.1.9.9.815.1.65
207
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

207 total
Object Name
me1200PtpMibPrivate PTP MIB.
MODULE-IDENTITY
.1.3.6.1.4.1.9.9.815.1.65
me1200PtpMibObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.815.1.65.1
me1200PtpCapabilities
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.815.1.65.1.1
me1200PtpCapabilitiesGlobals
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.815.1.65.1.1.1
me1200PtpCapabilitiesGlobalsClockCountThe number of PTP clocks supported by the device.ro
Unsigned32
.1.3.6.1.4.1.9.9.815.1.65.1.1.1.1
me1200PtpConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.815.1.65.1.2
me1200PtpConfigGlobals
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.815.1.65.1.2.1
me1200PtpConfigGlobalsExternalClockMode
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.815.1.65.1.2.1.1
me1200PtpConfigGlobalsExternalClockModeOnePpsModeThe mode of the PPS pin.rw
ME1200ptpExtClock1pps
.1.3.6.1.4.1.9.9.815.1.65.1.2.1.1.1
me1200PtpConfigGlobalsExternalClockModeExternalEnableExternal enable of PPS output.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.1.1.2
me1200PtpConfigGlobalsExternalClockModeAdjustMethodThe adjustment method of the PPS external output. 0: LTC Frequency 1: SyncE DPLL 2: Oscillator 3: LTC Phaserw
ME1200ptpPreferredAdj
.1.3.6.1.4.1.9.9.815.1.65.1.2.1.1.3
me1200PtpConfigGlobalsExternalClockModeClockFrequencyThe frequency in hertz (Hz) of the PPS external output.rw
Unsigned32
.1.3.6.1.4.1.9.9.815.1.65.1.2.1.1.4
me1200PtpConfigGlobalsSystemTimeSyncMode
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.815.1.65.1.2.1.2
me1200PtpConfigGlobalsSystemTimeSyncModeModeMode of the System time <-> ptp time synchronization.rw
ME1200ptpSystemTimeSyncMode
.1.3.6.1.4.1.9.9.815.1.65.1.2.1.2.1
me1200PtpConfigClocks
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.815.1.65.1.2.2
me1200PtpConfigClocksDefaultDsTableThis is the configurable part of the PTP clocks DefaultDS.
SEQUENCE OF ME1200PtpConfigClocksDefaultDsEntry
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.1
me1200PtpConfigClocksDefaultDsEntryThe clockId index must be a value must be a value from 0 up to the number of PTP clocks minus one.
ME1200PtpConfigClocksDefaultDsEntry
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.1.1
me1200PtpConfigClocksDefaultDsClockId-
Integer32
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.1.1.1
me1200PtpConfigClocksDefaultDsDeviceTypeThe PTP clock type.rw
ME1200ptpDeviceType
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.1.1.2
me1200PtpConfigClocksDefaultDsTwoStepFlagDetermines whether clock uses follow-up packets.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.1.1.3
me1200PtpConfigClocksDefaultDsPriority1The priority1 value.rw
ME1200Unsigned8 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.1.1.4
me1200PtpConfigClocksDefaultDsPriority2The priority2 value.rw
ME1200Unsigned8 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.1.1.5
me1200PtpConfigClocksDefaultDsOneWayDetermines whether clock uses sync packets only.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.1.1.6
me1200PtpConfigClocksDefaultDsDomainNumberThe domain number.rw
ME1200Unsigned8 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.1.1.7
me1200PtpConfigClocksDefaultDsProtocolThe protocol to be used for the encapsulation of the PTP packets.rw
ME1200ptpProtocol
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.1.1.8
me1200PtpConfigClocksDefaultDsVlanTagEnableDetermines whether clock uses sync packets only.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.1.1.9
me1200PtpConfigClocksDefaultDsVidThe VLAN id (if VLAN tagging is enabled).rw
ME1200Unsigned16 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.1.1.10
me1200PtpConfigClocksDefaultDsPcpThe PCP value (if VLAN tagging is enabled).rw
ME1200Unsigned8 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.1.1.11
me1200PtpConfigClocksDefaultDsMepThe mep instance number (if protocol is OAM).rw
Integer32
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.1.1.12
me1200PtpConfigClocksDefaultDsClkDomClock domain used.rw
Unsigned32
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.1.1.13
me1200PtpConfigClocksDefaultDsDscpThe DSCP field value (if protocol is IPv4).rw
ME1200Unsigned8 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.1.1.14
me1200PtpConfigClocksDefaultDsProfileThe PTP profile.rw
ME1200ptpProfile
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.1.1.15
me1200PtpConfigClocksDefaultDsLocalPriorityThe local priority value.rw
ME1200Unsigned8 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.1.1.16
me1200PtpConfigClocksDefaultDsActionActionrw
ME1200RowEditorState (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.1.1.100
me1200PtpConfigClocksDefaultDsTableRowEditor
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.2
me1200PtpConfigClocksDefaultDsTableRowEditorClockId-rw
Integer32
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.2.1
me1200PtpConfigClocksDefaultDsTableRowEditorDeviceTypeThe PTP clock type.rw
ME1200ptpDeviceType
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.2.2
me1200PtpConfigClocksDefaultDsTableRowEditorTwoStepFlagDetermines whether clock uses follow-up packets.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.2.3
me1200PtpConfigClocksDefaultDsTableRowEditorPriority1The priority1 value.rw
ME1200Unsigned8 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.2.4
me1200PtpConfigClocksDefaultDsTableRowEditorPriority2The priority2 value.rw
ME1200Unsigned8 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.2.5
me1200PtpConfigClocksDefaultDsTableRowEditorOneWayDetermines whether clock uses sync packets only.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.2.6
me1200PtpConfigClocksDefaultDsTableRowEditorDomainNumberThe domain number.rw
ME1200Unsigned8 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.2.7
me1200PtpConfigClocksDefaultDsTableRowEditorProtocolThe protocol to be used for the encapsulation of the PTP packets.rw
ME1200ptpProtocol
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.2.8
me1200PtpConfigClocksDefaultDsTableRowEditorVlanTagEnableDetermines whether clock uses sync packets only.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.2.9
me1200PtpConfigClocksDefaultDsTableRowEditorVidThe VLAN id (if VLAN tagging is enabled).rw
ME1200Unsigned16 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.2.10
me1200PtpConfigClocksDefaultDsTableRowEditorPcpThe PCP value (if VLAN tagging is enabled).rw
ME1200Unsigned8 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.2.11
me1200PtpConfigClocksDefaultDsTableRowEditorMepThe mep instance number (if protocol is OAM).rw
Integer32
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.2.12
me1200PtpConfigClocksDefaultDsTableRowEditorClkDomClock domain used.rw
Unsigned32
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.2.13
me1200PtpConfigClocksDefaultDsTableRowEditorDscpThe DSCP field value (if protocol is IPv4).rw
ME1200Unsigned8 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.2.14
me1200PtpConfigClocksDefaultDsTableRowEditorProfileThe PTP profile.rw
ME1200ptpProfile
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.2.15
me1200PtpConfigClocksDefaultDsTableRowEditorLocalPriorityThe local priority value.rw
ME1200Unsigned8 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.2.16
me1200PtpConfigClocksDefaultDsTableRowEditorActionActionrw
ME1200RowEditorState (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.2.100
me1200PtpConfigClocksTimePropertiesDsTableThis is the configurable part of the PTP clocks TimePropertiesDS.
SEQUENCE OF ME1200PtpConfigClocksTimePropertiesDsEntry
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.3
me1200PtpConfigClocksTimePropertiesDsEntryThe clockId index must be a value must be a value from 0 up to the number of PTP clocks minus one.
ME1200PtpConfigClocksTimePropertiesDsEntry
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.3.1
me1200PtpConfigClocksTimePropertiesDsClockId-
Integer32
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.3.1.1
me1200PtpConfigClocksTimePropertiesDsCurrentUtcOffsetThe current UTC time offset.rw
ME1200Integer16 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.3.1.2
me1200PtpConfigClocksTimePropertiesDsCurrentUtcOffsetValidIndicates whether the current UTC time offset value is valid.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.3.1.3
me1200PtpConfigClocksTimePropertiesDsLeap59Indicates that the last minute of the day has only 59 seconds.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.3.1.4
me1200PtpConfigClocksTimePropertiesDsLeap61Indicates that the last minute of the day has 61 seconds.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.3.1.5
me1200PtpConfigClocksTimePropertiesDsTimeTraceableIndicates that time is traceable to a primary reference.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.3.1.6
me1200PtpConfigClocksTimePropertiesDsFrequencyTraceableIndicates that frequency is traceable to a primary reference.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.3.1.7
me1200PtpConfigClocksTimePropertiesDsPtpTimescaleIndicates whether timescale of the grandmaster clock is PTP.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.3.1.8
me1200PtpConfigClocksTimePropertiesDsTimeSourceSource of time used by the grandmaster clock.rw
ME1200Unsigned8 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.3.1.9
me1200PtpConfigClocksFilterParametersTableThis is the configurable part of the PTP clocks filter parameters.
SEQUENCE OF ME1200PtpConfigClocksFilterParametersEntry
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.4
me1200PtpConfigClocksFilterParametersEntryThe clockId index must be a value must be a value from 0 up to the number of PTP clocks minus one.
ME1200PtpConfigClocksFilterParametersEntry
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.4.1
me1200PtpConfigClocksFilterParametersClockId-
Integer32
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.4.1.1
me1200PtpConfigClocksFilterParametersDelayFilterDefines the time constant of the delay filter.rw
Unsigned32
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.4.1.2
me1200PtpConfigClocksFilterParametersFilterTypeSelects the type of filter/servo used.rw
Unsigned32
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.4.1.3
me1200PtpConfigClocksFilterParametersPeriodDefines the period of the offset filter.rw
Unsigned32
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.4.1.4
me1200PtpConfigClocksFilterParametersDistSets the dist value of the offset filter.rw
Unsigned32
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.4.1.5
me1200PtpConfigClocksServoParametersTableThis is the configurable part of the PTP clocks servo parameters.
SEQUENCE OF ME1200PtpConfigClocksServoParametersEntry
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.5
me1200PtpConfigClocksServoParametersEntryThe clockId index must be a value must be a value from 0 up to the number of PTP clocks minus one.
ME1200PtpConfigClocksServoParametersEntry
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.5.1
me1200PtpConfigClocksServoParametersClockId-
Integer32
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.5.1.1
me1200PtpConfigClocksServoParametersDisplayIndicates whether output shall be sent to the debug terminal.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.5.1.2
me1200PtpConfigClocksServoParametersPEnableIndicates whether P-value of servo algorithm shall be used.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.5.1.3
me1200PtpConfigClocksServoParametersIEnableIndicates whether I-value of servo algorithm shall be used.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.5.1.4
me1200PtpConfigClocksServoParametersDEnableIndicates whether D-value of servo algorithm shall be used.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.5.1.5
me1200PtpConfigClocksServoParametersPvalP-value of the offset filter.rw
Unsigned32
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.5.1.6
me1200PtpConfigClocksServoParametersIvalI-value of the offset filter.rw
Unsigned32
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.5.1.7
me1200PtpConfigClocksServoParametersDvalD-value of the offset filter.rw
Unsigned32
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.5.1.8
me1200PtpConfigClocksServoParametersSrvOptionD-value of the offset filter.rw
ME1200ptpServoClockOption
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.5.1.9
me1200PtpConfigClocksServoParametersSynceThresholdSyncE Thresholdrw
Unsigned32
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.5.1.10
me1200PtpConfigClocksServoParametersSynceApSyncE Aprw
Unsigned32
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.5.1.11
me1200PtpConfigClocksServoParametersHoFilterHoldoff low pass filter constant.rw
Integer32
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.5.1.12
me1200PtpConfigClocksServoParametersStableAdjThresholdThreshold at which offset is assumed to be stable.rw
ME1200Unsigned64 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.5.1.13
me1200PtpConfigClocksSlaveConfigTableThis is the configurable part of the PTP clocks slave configuration.
SEQUENCE OF ME1200PtpConfigClocksSlaveConfigEntry
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.6
me1200PtpConfigClocksSlaveConfigEntryThe clockId index must be a value must be a value from 0 up to the number of PTP clocks minus one.
ME1200PtpConfigClocksSlaveConfigEntry
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.6.1
me1200PtpConfigClocksSlaveConfigClockId-
Integer32
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.6.1.1
me1200PtpConfigClocksSlaveConfigStableOffsetStable offset threshold in ns.rw
Unsigned32
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.6.1.2
me1200PtpConfigClocksSlaveConfigOffsetOkOffset OK threshold in ns.rw
Unsigned32
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.6.1.3
me1200PtpConfigClocksSlaveConfigOffsetFailOffset fail threshold in ns.rw
Unsigned32
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.6.1.4
me1200PtpConfigClocksUnicastSlaveConfigTableThis is the configurable part of the PTP clocks unicast slave configuration.
SEQUENCE OF ME1200PtpConfigClocksUnicastSlaveConfigEntry
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.7
me1200PtpConfigClocksUnicastSlaveConfigEntryThe clockId index must be a value must be a value from 0 up to the number of PTP clocks minus one.
ME1200PtpConfigClocksUnicastSlaveConfigEntry
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.7.1
me1200PtpConfigClocksUnicastSlaveConfigClockId-
Integer32
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.7.1.1
me1200PtpConfigClocksUnicastSlaveConfigMasterId-
Integer32
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.7.1.2
me1200PtpConfigClocksUnicastSlaveConfigDurationNumber of seconds for which the Announce/Sync messages are requested.rw
Unsigned32
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.7.1.3
me1200PtpConfigClocksUnicastSlaveConfigIpAddressIPv4 address of requested master clock.rw
IpAddress
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.7.1.4
me1200PtpConfigClocksPortDsTableThis is the configurable part of the PTP clocks PortDS.
SEQUENCE OF ME1200PtpConfigClocksPortDsEntry
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.8
me1200PtpConfigClocksPortDsEntryThe clockId index must be a value must be a value from 0 up to the number of PTP clocks minus one.
ME1200PtpConfigClocksPortDsEntry
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.8.1
me1200PtpConfigClocksPortDsClockId-
Integer32
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.8.1.1
me1200PtpConfigClocksPortDsPortId-
ME1200InterfaceIndex
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.8.1.2
me1200PtpConfigClocksPortDsEnabledDefines whether port is enabled.rw
ME1200Unsigned8 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.8.1.3
me1200PtpConfigClocksPortDsLogAnnounceIntervalInterval between announce message transmissions.rw
ME1200Integer16 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.8.1.4
me1200PtpConfigClocksPortDsAnnounceReceiptTimeoutThe timeout for receiving announce messages on the port.rw
ME1200Unsigned8 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.8.1.5
me1200PtpConfigClocksPortDsLogSyncIntervalThe interval for issuing sync meesages in the master.rw
ME1200Integer16 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.8.1.6
me1200PtpConfigClocksPortDsDelayMechanismThe delay mechanism used for the port.rw
ME1200Unsigned8 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.8.1.7
me1200PtpConfigClocksPortDsLogMinPdelayReqIntervalThe value of logMinPdelayReqIntervalrw
ME1200Integer16 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.8.1.8
me1200PtpConfigClocksPortDsDelayAsymmetryThe value for the communication path asymmetry.rw
ME1200Integer64 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.8.1.9
me1200PtpConfigClocksPortDsIngressLatencyIngress delay for port.rw
ME1200Integer64 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.8.1.10
me1200PtpConfigClocksPortDsEgressLatencyEgress delay for port.rw
ME1200Integer64 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.8.1.11
me1200PtpConfigClocksPortDsPortInternalDefines whether port is enabled as an internal interface.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.8.1.12
me1200PtpConfigClocksPortDsVersionNumberThe version of PTP being used by the port.rw
ME1200Unsigned16 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.8.1.13
me1200PtpConfigClocksPortDsMcastAddrThe multicast address used (default or link local).rw
ME1200ptpDestAdrType
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.8.1.14
me1200PtpConfigClocksPortDsNotSlaveWhen true, the port will not act as a slave.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.8.1.15
me1200PtpConfigClocksPortDsLocalPriorityThe local priority value.rw
ME1200Unsigned8 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.2.2.8.1.16
me1200PtpStatus
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.815.1.65.1.3
me1200PtpStatusClocks
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.815.1.65.1.3.1
me1200PtpStatusClocksDefaultDsTableThis is the dynamic (status) part of the PTP clocks DefaultDS.
SEQUENCE OF ME1200PtpStatusClocksDefaultDsEntry
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.1
me1200PtpStatusClocksDefaultDsEntryThe clockId index must be a value must be a value from 0 up to the number of PTP clocks minus one.
ME1200PtpStatusClocksDefaultDsEntry
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.1.1
me1200PtpStatusClocksDefaultDsClockId-
Integer32
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.1.1.1
me1200PtpStatusClocksDefaultDsClockIdentityThis is the unique 8 byte clockIdentify field from the DefaultDS structure.ro
OCTET STRING
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.1.1.2
me1200PtpStatusClocksDefaultDsClockQualityClockClassThis is the clock class field of the clock quality structure.ro
ME1200Unsigned8 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.1.1.3
me1200PtpStatusClocksDefaultDsClockQualityClockAccuracyThis is the clock accuracy field of the clock quality structure.ro
ME1200Unsigned8 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.1.1.4
me1200PtpStatusClocksDefaultDsClockQualityOffsetScaledLogVarThis is the offsetScaledLogVariance field of the clock quality structure.ro
ME1200Unsigned16 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.1.1.5
me1200PtpStatusClocksCurrentDsTableThis is the dynamic (status) part of the PTP clocks CurrentDS.
SEQUENCE OF ME1200PtpStatusClocksCurrentDsEntry
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.2
me1200PtpStatusClocksCurrentDsEntryThe clockId index must be a value must be a value from 0 up to the number of PTP clocks minus one.
ME1200PtpStatusClocksCurrentDsEntry
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.2.1
me1200PtpStatusClocksCurrentDsClockId-
Integer32
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.2.1.1
me1200PtpStatusClocksCurrentDsStepsRemovedThe number of PTP clocks traversed from the grandmaster to the local PTP clock.ro
ME1200Unsigned16 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.2.1.2
me1200PtpStatusClocksCurrentDsOffsetFromMasterThe time differece in ns from the grandmaster to the local PTP clock.ro
ME1200Integer64 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.2.1.3
me1200PtpStatusClocksCurrentDsMeanPathDelayThe mean path delay from the master to the local slave.ro
ME1200Integer64 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.2.1.4
me1200PtpStatusClocksParentDsTableThis is the dynamic (status) part of the PTP clocks ParentDS.
SEQUENCE OF ME1200PtpStatusClocksParentDsEntry
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.3
me1200PtpStatusClocksParentDsEntryThe clockId index must be a value must be a value from 0 up to the number of PTP clocks minus one.
ME1200PtpStatusClocksParentDsEntry
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.3.1
me1200PtpStatusClocksParentDsClockId-
Integer32
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.3.1.1
me1200PtpStatusClocksParentDsParentPortIdentityClockIdentityThis is the 8 byte unique clock identity of the parent port.ro
OCTET STRING
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.3.1.2
me1200PtpStatusClocksParentDsParentPortIdentityPortNumberThis is the port number on the parent associated with the parent clock.ro
ME1200Unsigned16 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.3.1.3
me1200PtpStatusClocksParentDsParentStatsParents stats (always false).ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.3.1.4
me1200PtpStatusClocksParentDsObservedParentOffsetScaledLogVarThis field is optional and is not computed (as signaled by parentStats being false).ro
ME1200Unsigned16 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.3.1.5
me1200PtpStatusClocksParentDsObservedParentClockPhaseChangeRateThis field is optional and is not computed (as signaled by parentStats being false).ro
Integer32
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.3.1.6
me1200PtpStatusClocksParentDsGrmstrIdentityThis is the 8 byte unique clock identity of the grand master clock.ro
OCTET STRING
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.3.1.7
me1200PtpStatusClocksParentDsGrmstrClkQualClockClassThis is the clock class of the clock quality structure of the grand master clock.ro
ME1200Unsigned8 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.3.1.8
me1200PtpStatusClocksParentDsGmstrClkQualClockAccuracyThis is the clock accuracy of the clock quality structure of the grand master clock.ro
ME1200Unsigned8 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.3.1.9
me1200PtpStatusClocksParentDsGmstrClkQualOffsetScaledLogVarThis is the offsetScaledLogVariance field of the clock quality structure of the grand master clock.ro
ME1200Unsigned16 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.3.1.10
me1200PtpStatusClocksParentDsGmstrPriority1Grandmaster Priority1 value.ro
ME1200Unsigned8 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.3.1.11
me1200PtpStatusClocksParentDsGmstrPriority2Grandmaster Priority2 value.ro
ME1200Unsigned8 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.3.1.12
me1200PtpStatusClocksTimePropertiesDsTableThis is the dynamic (status) part of the PTP clocks TimePropertiesDS.
SEQUENCE OF ME1200PtpStatusClocksTimePropertiesDsEntry
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.4
me1200PtpStatusClocksTimePropertiesDsEntryThe clockId index must be a value must be a value from 0 up to the number of PTP clocks minus one.
ME1200PtpStatusClocksTimePropertiesDsEntry
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.4.1
me1200PtpStatusClocksTimePropertiesDsClockId-
Integer32
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.4.1.1
me1200PtpStatusClocksTimePropertiesDsCurrentUtcOffsetThe current UTC time offset.ro
ME1200Integer16 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.4.1.2
me1200PtpStatusClocksTimePropertiesDsCurrentUtcOffsetValidIndicates whether the current UTC time offset value is valid.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.4.1.3
me1200PtpStatusClocksTimePropertiesDsLeap59Indicates that the last minute of the day has only 59 seconds.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.4.1.4
me1200PtpStatusClocksTimePropertiesDsLeap61Indicates that the last minute of the day has 61 seconds.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.4.1.5
me1200PtpStatusClocksTimePropertiesDsTimeTraceableIndicates that time is traceable to a primary reference.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.4.1.6
me1200PtpStatusClocksTimePropertiesDsFrequencyTraceableIndicates that frequency is traceable to a primary reference.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.4.1.7
me1200PtpStatusClocksTimePropertiesDsPtpTimescaleIndicates whether timescale of the grandmaster clock is PTP.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.4.1.8
me1200PtpStatusClocksTimePropertiesDsTimeSourceSource of time used by the grandmaster clock.ro
ME1200Unsigned8 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.4.1.9
me1200PtpStatusClocksSlaveDsTableThis is the dynamic (status) part of the PTP clocks SlaveDS.
SEQUENCE OF ME1200PtpStatusClocksSlaveDsEntry
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.5
me1200PtpStatusClocksSlaveDsEntryThe clockId index must be a value must be a value from 0 up to the number of PTP clocks minus one.
ME1200PtpStatusClocksSlaveDsEntry
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.5.1
me1200PtpStatusClocksSlaveDsClockId-
Integer32
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.5.1.1
me1200PtpStatusClocksSlaveDsSlavePort0 => no slave port, 1..n => selected slave port.ro
ME1200Unsigned16 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.5.1.2
me1200PtpStatusClocksSlaveDsSlaveStateThe slaves state.ro
ME1200ptpSlaveClockState
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.5.1.3
me1200PtpStatusClocksSlaveDsHoldoverStableTrue if the stabilization period has expired.ro
ME1200Unsigned8 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.5.1.4
me1200PtpStatusClocksSlaveDsHoldoverAdjThe calculated holdover offset (ppb*10).ro
ME1200Integer64 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.5.1.5
me1200PtpStatusClocksUnicastMasterTableThis is the dynamic (status) part of the PTP clocks unicast master table.
SEQUENCE OF ME1200PtpStatusClocksUnicastMasterEntry
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.6
me1200PtpStatusClocksUnicastMasterEntryThe clockId index must be a value must be a value from 0 up to the number of PTP clocks minus one.
ME1200PtpStatusClocksUnicastMasterEntry
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.6.1
me1200PtpStatusClocksUnicastMasterClockId-
Integer32
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.6.1.1
me1200PtpStatusClocksUnicastMasterSlaveIp-
IpAddress
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.6.1.2
me1200PtpStatusClocksUnicastMasterSlaveMac-ro
MacAddress (SNMPv2-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.6.1.3
me1200PtpStatusClocksUnicastMasterPortPort on the master that slave is connected to.ro
ME1200Unsigned16 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.6.1.4
me1200PtpStatusClocksUnicastMasterAnnLogMsgPeriodThe granted Announce interval.ro
ME1200Integer16 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.6.1.5
me1200PtpStatusClocksUnicastMasterAnnTrue if sending announce messages.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.6.1.6
me1200PtpStatusClocksUnicastMasterLogMsgPeriodThe granted sync interval.ro
ME1200Integer16 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.6.1.7
me1200PtpStatusClocksUnicastMasterSyncTrue if sending sync messages.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.6.1.8
me1200PtpStatusClocksUnicastSlaveTableThis is the dynamic (status) part of the PTP clocks unicast slave table.
SEQUENCE OF ME1200PtpStatusClocksUnicastSlaveEntry
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.7
me1200PtpStatusClocksUnicastSlaveEntryThe clockId index must be a value must be a value from 0 up to the number of PTP clocks minus one.
ME1200PtpStatusClocksUnicastSlaveEntry
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.7.1
me1200PtpStatusClocksUnicastSlaveClockId-
Integer32
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.7.1.1
me1200PtpStatusClocksUnicastSlaveMasterId-
Integer32
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.7.1.2
me1200PtpStatusClocksUnicastSlaveMasterIpThis is the IP address of the master.ro
IpAddress
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.7.1.3
me1200PtpStatusClocksUnicastSlaveMasterMacThis is the MAC address of the master.ro
MacAddress (SNMPv2-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.7.1.4
me1200PtpStatusClocksUnicastSlaveSourcePortIdentityClockIdentityThis is the 8 byte unique clock identity of the source port.ro
OCTET STRING
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.7.1.5
me1200PtpStatusClocksUnicastSlaveSourcePortIdentityPortNumberThis is port number of the port used on the source.ro
ME1200Unsigned16 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.7.1.6
me1200PtpStatusClocksUnicastSlavePortThe port (on the slave) connected to the master.ro
ME1200Unsigned16 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.7.1.7
me1200PtpStatusClocksUnicastSlaveLogMsgPeriodThe granted sync interval.ro
ME1200Integer16 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.7.1.8
me1200PtpStatusClocksUnicastSlaveCommStateCommunication state.ro
ME1200ptpUcCommState
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.7.1.9
me1200PtpStatusClocksUnicastSlaveConfMasterIpCopy of the destination ip address.ro
IpAddress
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.7.1.10
me1200PtpStatusClocksPortsDsTableThis is the dynamic (status) part of the PTP clocks PortDS.
SEQUENCE OF ME1200PtpStatusClocksPortsDsEntry
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.8
me1200PtpStatusClocksPortsDsEntryThe clockId index must be a value must be a value from 0 up to the number of PTP clocks minus one.
ME1200PtpStatusClocksPortsDsEntry
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.8.1
me1200PtpStatusClocksPortsDsClockId-
Integer32
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.8.1.1
me1200PtpStatusClocksPortsDsPortId-
ME1200InterfaceIndex
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.8.1.2
me1200PtpStatusClocksPortsDsPortState-ro
ME1200ptpClockPortState
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.8.1.3
me1200PtpStatusClocksPortsDsLogMinDelayReqInterval-ro
ME1200Integer16 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.8.1.4
me1200PtpStatusClocksPortsDsPeerMeanPathDelay-ro
ME1200Integer64 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.8.1.5
me1200PtpStatusClocksPortsDsPeerDelayOk-ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.3.1.8.1.6
me1200PtpControl
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.815.1.65.1.4
me1200PtpControlClocksTableThis is the PTP clocks control structure.
SEQUENCE OF ME1200PtpControlClocksEntry
.1.3.6.1.4.1.9.9.815.1.65.1.4.1
me1200PtpControlClocksEntryThe clockId index must be a value must be a value from 0 up to the number of PTP clocks minus one.
ME1200PtpControlClocksEntry
.1.3.6.1.4.1.9.9.815.1.65.1.4.1.1
me1200PtpControlClocksClockId-
Integer32
.1.3.6.1.4.1.9.9.815.1.65.1.4.1.1.1
me1200PtpControlClocksSyncToSystemClock-rw
ME1200Unsigned8 (ME1200-TC)
.1.3.6.1.4.1.9.9.815.1.65.1.4.1.1.2
me1200PtpStatistics
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.815.1.65.1.5
me1200PtpNotifs
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.815.1.65.1.6
me1200PtpNotifsPortStateChangeAn me1200PtpNotifsPortStateChange notification is sent when the Port State changes occurs. Port State is an enumerated integer value. Description of various possible Port States is: initializing - In this state a port initializes its data sets, hardware, and communication facilities. faulty - The fault state of the protocol. disabled - The port shall not place any messages on its communication path. listening - The port is waiting for the announceReceiptTimeout to expire or to receive an Announce message from a master. preMaster - The port shall behave in all respects as though it were in the MASTER state except that it shall not place any messages on its communication path except for Pdelay_Req, Pdelay_Resp, Pdelay_Resp_Follow_Up, signaling, or management messages. master - The port is behaving as a master port. passive - The port shall not place any messages on its communication path except for Pdelay_Req, Pdelay_Resp, Pdelay_Resp_Follow_Up, or signaling messages, or management messages that are a required response to another management message uncalibrated - The local port is preparing to synchronize to the master port. slave - The port is synchronizing to the selected master port. p2pTransparent - The port is in point to point transparent state. e2eTransparent - The port is in end to end transparent state.
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.815.1.65.1.6.1
me1200PtpNotifsClockSlaveStateChangeAn me1200PtpNotifsClockSlaveStateChange notification is sent when the clock slave state changes. Clock Slave Sate is an enumerated integer value. Description of various possible Port States is: Freerun - Applies to a slave device that is not locked to a master. This is the initial state a slave starts out with when it is not getting any PTP packets from the master or because of some other input error (erroneous packets, etc). FreqLocking - The slave device is receiving packets from a master and is trying to acquire a frequency lock. PhaseLocking - The slave device is receiving packets from a master and is trying to acquire a phase lock. Locked - Locked to the master with respect to frequency and phase. Holdover - In this state the slave device is locked to a master but communication with the master is lost or the timestamps in the ptp packets are incorrect. But since the slave was locked to the master, it can run with the same accuracy for sometime. The slave can continue to operate in this state for some time. If communication with the master is not restored for a while, the device is moved to the FREERUN state. Invalid - The slave is in Invalid state.
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.815.1.65.1.6.2
me1200PtpNotifsUnicastCommunicationStateChangeAn me1200PtpNotifsUnicastCommunicationStateChange notification is sent when the unicast communication state changes (A unicast slave reports change in the communication state to the configured masters). Unicast communication state is an enumerated integer value. Description of various possible states is: idle - When communication state is idle. intializing - When communication state is initializing. connected - When communication state is connected. selected - When communication state is selected. synced - When communication state is synced.
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.815.1.65.1.6.3
me1200PtpNotifsUnicastSlaveAppearsAn me1200PtpNotifsUnicastSlaveAppears notification is sent when a unicast slave appears.
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.815.1.65.1.6.4
me1200PtpNotifsUnicastSlaveDisappearsAn me1200PtpNotifsUnicastSlaveDisappears notification is sent when a unicast slave disappears.
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.815.1.65.1.6.5
me1200PtpMibConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.815.1.65.2
me1200PtpMibCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.815.1.65.2.1
me1200PtpMibGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.815.1.65.2.2
ME1200-PTP-MIB - SNMP MIB Reference | MIBs Explorer