ME1200-DDMI-MIB
Imported Objects
Objects
49 total| Object Name |
|---|
me1200DdmiMibThis is a private version of DDMI MODULE-IDENTITY .1.3.6.1.4.1.9.9.815.1.121 |
me1200DdmiMibObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.815.1.121.1 |
me1200DdmiConfig OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.815.1.121.1.2 |
me1200DdmiConfigGlobals OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.815.1.121.1.2.1 |
me1200DdmiConfigGlobalsModeGlobal operation mode of DDMI. true(1) is to enable the functions of
DDMI and false(2) is to disable it.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.815.1.121.1.2.1.1 |
me1200DdmiStatus OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.815.1.121.1.3 |
me1200DdmiStatusInterfaceTableThis is a DDMI status table of port interface. SEQUENCE OF ME1200DdmiStatusInterfaceEntry .1.3.6.1.4.1.9.9.815.1.121.1.3.2 |
me1200DdmiStatusInterfaceEntryEach entry has a set of DDMI status. ME1200DdmiStatusInterfaceEntry .1.3.6.1.4.1.9.9.815.1.121.1.3.2.1 |
me1200DdmiStatusInterfaceIfIndexLogical interface number of physical port. ME1200InterfaceIndex (ME1200-TC) .1.3.6.1.4.1.9.9.815.1.121.1.3.2.1.1 |
me1200DdmiStatusInterfaceA0SupportedSupport transceiver status information or not. true(1) is to supported
and false(2) is not supported.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.815.1.121.1.3.2.1.2 |
me1200DdmiStatusInterfaceA0SfpDetectedSFP module is detected or not. true(1) is to detected and false(2) is
not detected.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.815.1.121.1.3.2.1.3 |
me1200DdmiStatusInterfaceA0VendorVendor name.ro ME1200DisplayString .1.3.6.1.4.1.9.9.815.1.121.1.3.2.1.4 |
me1200DdmiStatusInterfaceA0PartNumberPart number.ro ME1200DisplayString .1.3.6.1.4.1.9.9.815.1.121.1.3.2.1.5 |
me1200DdmiStatusInterfaceA0SerialNumberSerial number.ro ME1200DisplayString .1.3.6.1.4.1.9.9.815.1.121.1.3.2.1.6 |
me1200DdmiStatusInterfaceA0RevisionRevision.ro ME1200DisplayString .1.3.6.1.4.1.9.9.815.1.121.1.3.2.1.7 |
me1200DdmiStatusInterfaceA0DateCodeDate Code.ro ME1200DisplayString .1.3.6.1.4.1.9.9.815.1.121.1.3.2.1.8 |
me1200DdmiStatusInterfaceA0SfpTypeSFP type. none(0) means no SFP module. notSupported(1) means SFP module
is not supported. sfp100Fx(2) means SFP 100BASE-FX. sfp100BaseLx(3)
means SFP 100BASE-LX. sfp100BaseBx10(4) means SFP 100BASE-BX10.
sfp100BaseT(5) means SFP 100BASE-T. sfp1000BaseBx10(6) means SFP
1000BASE-BX10. sfp1000BaseT(7) means SFP 1000BASE-T. sfp1000BaseCx(8)
means SFP 1000BASE-CX. sfp1000BaseSx(9) means SFP 1000BASE-SX.
sfp1000BaseLx(10) means SFP 1000BASE-LX. sfp1000BaseX(11) means SFP
1000BASE-X. sfp2G5(12) means SFP 2.5G. sfp5G(13) means SFP 5G.
sfp10G(14) means SFP 10G.ro ME1200DdmiSfpTransceiver .1.3.6.1.4.1.9.9.815.1.121.1.3.2.1.9 |
me1200DdmiStatusInterfaceA2SupportedSupport DDMI status information or not. true(1) is to supported and
false(2) is not supported.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.815.1.121.1.3.2.1.1002 |
me1200DdmiStatusInterfaceA2CurrentTemperatureCurrent temperature in Celcius.ro ME1200DisplayString .1.3.6.1.4.1.9.9.815.1.121.1.3.2.1.1003 |
me1200DdmiStatusInterfaceA2TemperatureHighAlarmThresholdTemperature high alarm threshold in Celcius.ro ME1200DisplayString .1.3.6.1.4.1.9.9.815.1.121.1.3.2.1.1004 |
me1200DdmiStatusInterfaceA2TemperatureLowAlarmThresholdTemperature low alarm threshold in Celcius.ro ME1200DisplayString .1.3.6.1.4.1.9.9.815.1.121.1.3.2.1.1005 |
me1200DdmiStatusInterfaceA2TemperatureHighWarnThresholdTemperature high warning threshold in Celcius.ro ME1200DisplayString .1.3.6.1.4.1.9.9.815.1.121.1.3.2.1.1006 |
me1200DdmiStatusInterfaceA2TemperatureLowWarnThresholdTemperature low warning threshold in Celcius.ro ME1200DisplayString .1.3.6.1.4.1.9.9.815.1.121.1.3.2.1.1007 |
me1200DdmiStatusInterfaceA2CurrentVoltageCurrent voltage in Volt.ro ME1200DisplayString .1.3.6.1.4.1.9.9.815.1.121.1.3.2.1.1008 |
me1200DdmiStatusInterfaceA2VoltageHighAlarmThresholdVoltage high alarm threshold in Volt.ro ME1200DisplayString .1.3.6.1.4.1.9.9.815.1.121.1.3.2.1.1009 |
me1200DdmiStatusInterfaceA2VoltageLowAlarmThresholdVoltage low alarm threshold in Volt.ro ME1200DisplayString .1.3.6.1.4.1.9.9.815.1.121.1.3.2.1.1010 |
me1200DdmiStatusInterfaceA2VoltageHighWarnThresholdVoltage high warning threshold in Volt.ro ME1200DisplayString .1.3.6.1.4.1.9.9.815.1.121.1.3.2.1.1011 |
me1200DdmiStatusInterfaceA2VoltageLowWarnThresholdVoltage low warning threshold in Volt.ro ME1200DisplayString .1.3.6.1.4.1.9.9.815.1.121.1.3.2.1.1012 |
me1200DdmiStatusInterfaceA2CurrentTxBiasCurrent Tx bias in mA.ro ME1200DisplayString .1.3.6.1.4.1.9.9.815.1.121.1.3.2.1.1013 |
me1200DdmiStatusInterfaceA2TxBiasHighAlarmThresholdTx bias high alarm threshold in mA.ro ME1200DisplayString .1.3.6.1.4.1.9.9.815.1.121.1.3.2.1.1014 |
me1200DdmiStatusInterfaceA2TxBiasLowAlarmThresholdTx bias low alarm threshold in mA.ro ME1200DisplayString .1.3.6.1.4.1.9.9.815.1.121.1.3.2.1.1015 |
me1200DdmiStatusInterfaceA2TxBiasHighWarnThresholdTx bias high warning threshold in mA.ro ME1200DisplayString .1.3.6.1.4.1.9.9.815.1.121.1.3.2.1.1016 |
me1200DdmiStatusInterfaceA2TxBiasLowWarnThresholdTx bias low warning threshold in mA.ro ME1200DisplayString .1.3.6.1.4.1.9.9.815.1.121.1.3.2.1.1017 |
me1200DdmiStatusInterfaceA2CurrentTxPowerCurrent Tx power in mV.ro ME1200DisplayString .1.3.6.1.4.1.9.9.815.1.121.1.3.2.1.1018 |
me1200DdmiStatusInterfaceA2TxPowerHighAlarmThresholdTx power high alarm threshold in mV.ro ME1200DisplayString .1.3.6.1.4.1.9.9.815.1.121.1.3.2.1.1019 |
me1200DdmiStatusInterfaceA2TxPowerLowAlarmThresholdTx power low alarm threshold in mV.ro ME1200DisplayString .1.3.6.1.4.1.9.9.815.1.121.1.3.2.1.1020 |
me1200DdmiStatusInterfaceA2TxPowerHighWarnThresholdTx power high warning threshold in mV.ro ME1200DisplayString .1.3.6.1.4.1.9.9.815.1.121.1.3.2.1.1021 |
me1200DdmiStatusInterfaceA2TxPowerLowWarnThresholdTx power low warning threshold in mV.ro ME1200DisplayString .1.3.6.1.4.1.9.9.815.1.121.1.3.2.1.1022 |
me1200DdmiStatusInterfaceA2CurrentRxPowerCurrent Rx power in mV.ro ME1200DisplayString .1.3.6.1.4.1.9.9.815.1.121.1.3.2.1.1023 |
me1200DdmiStatusInterfaceA2RxPowerHighAlarmThresholdRx power high alarm threshold in mV.ro ME1200DisplayString .1.3.6.1.4.1.9.9.815.1.121.1.3.2.1.1024 |
me1200DdmiStatusInterfaceA2RxPowerLowAlarmThresholdRx power low alarm threshold in mV.ro ME1200DisplayString .1.3.6.1.4.1.9.9.815.1.121.1.3.2.1.1025 |
me1200DdmiStatusInterfaceA2RxPowerHighWarnThresholdRx power high warning threshold in mV.ro ME1200DisplayString .1.3.6.1.4.1.9.9.815.1.121.1.3.2.1.1026 |
me1200DdmiStatusInterfaceA2RxPowerLowWarnThresholdRx power low warning threshold in mV.ro ME1200DisplayString .1.3.6.1.4.1.9.9.815.1.121.1.3.2.1.1027 |
me1200DdmiNotificationPrefix OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.815.1.121.1.4 |
me1200DdmitNotification OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.815.1.121.1.4.0 |
me1200DdmiNotificationSFPErrorTypeNotification is sent when the SFP module DDMI is supported but read failed. NOTIFICATION-TYPE .1.3.6.1.4.1.9.9.815.1.121.1.4.0.1 |
me1200DdmiMibConformance OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.815.1.121.2 |
me1200DdmiMibCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.815.1.121.2.1 |
me1200DdmiMibGroups OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.815.1.121.2.2 |
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-ENTITY-VENDORTYPE-OID-MIB maps Cisco-specific hardware component identifiers to the ENTITY-MIB's entPhysicalTable, enabling precise differentiation of physical device types such as line cards, power supplies, and fans within Cisco infrastructure. This mapping ensures that SNMP management systems can accurately correlate physical inventory entries with vendor-specific component definitions for accurate device discovery and monitoring.
The CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB provides SNMP-based monitoring and management of Cisco Unified Computing System (UCS) hardware components, including chassis, blades, fabric interconnects, and power supplies. It exposes critical operational metrics such as device status, port states, temperature readings, fan speeds, and power consumption data for infrastructure health assessment.
The CISCO-UNIFIED-COMPUTING-ADAPTOR-MIB enables SNMP-based monitoring and management of physical and virtual network adapter interfaces, including link status, traffic counters, error statistics, and port configuration parameters, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers.
The CISCO-UNIFIED-COMPUTING-TC-MIB module defines standard textual conventions and data type definitions required for monitoring Cisco Unified Computing System (UCS) hardware components, including server blades, fabric interconnects, and chassis resources. These definitions enable consistent interpretation of specific UCS metrics such as power supply status, fan speeds, thermal readings, and port utilization across SNMP management applications.
The CISCO-UNIFIED-COMPUTING-FABRIC-MIB enables SNMP-based monitoring and management of the Cisco UCS Fabric Interconnects and associated fabric switching infrastructure, exposing metrics for port states, link utilization, error counters, and fabric topology status. It facilitates granular visibility into the physical and logical fabric layers, including uplink/downlink interfaces, VLAN configurations, and fabric failover conditions within the unified computing environment.
The STARENT-MIB module provides SNMP management and monitoring capabilities for Cisco ASR 5000 and ASR 5500 multimedia core platforms, specifically exposing metrics related to 2G/3G/4G and WiFi subscriber sessions, inline service states, and carrier-class high-availability status.