LSI-MegaRAID-SAS-MIB
Detailed view of the defined objects, syntax rules, and hierarchical paths.
414
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
414 total| Object Name |
|---|
lsi OBJECT IDENTIFIER .1.3.6.1.4.1.3582 |
RFC1213-MIB Unknown .1.3.6.1.4.1.3582 |
storageComponents OBJECT IDENTIFIER .1.3.6.1.4.1.3582.4 |
lsiRAIDServer OBJECT IDENTIFIER .1.3.6.1.4.1.3582.4.1 |
hostNameName of the host system.ro DisplayString .1.3.6.1.4.1.3582.4.1.1 |
hostOSInfoOperating System description where SNMP agent is running.ro DisplayString .1.3.6.1.4.1.3582.4.1.2 |
versionInfo OBJECT IDENTIFIER .1.3.6.1.4.1.3582.4.1.3 |
mibVersionThe MIB version no. (xx.yy)ro DisplayString .1.3.6.1.4.1.3582.4.1.3.1 |
agentModuleNameThe agent module namero DisplayString .1.3.6.1.4.1.3582.4.1.3.2 |
agentModuleVersionThe module version in xx.yy format. Where xx is the major version number and yy is the minor version number(without build information).ro DisplayString .1.3.6.1.4.1.3582.4.1.3.3 |
releaseDateModule Release Datero DisplayString .1.3.6.1.4.1.3582.4.1.3.4 |
megaRAID-SAS OBJECT IDENTIFIER .1.3.6.1.4.1.3582.4.1.4 |
adapter OBJECT IDENTIFIER .1.3.6.1.4.1.3582.4.1.4.1 |
adpNumberThe total no of SAS adapters present.ro Gauge .1.3.6.1.4.1.3582.4.1.4.1.1 |
adapterPropertiesTableA List of adapter Entries containing Information/Properties about the adapters. SEQUENCE OF AdapterPropertiesEntry .1.3.6.1.4.1.3582.4.1.4.1.2 |
adapterPropertiesEntryAn Entry in the adapter table. AdapterPropertiesEntry .1.3.6.1.4.1.3582.4.1.4.1.2.1 |
adapterID-APTAdapterID for this Adapter.(Unique)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.1 |
rebuildRateRebuild rate on this Adapter.rw INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.2 |
reconstructionRateReconstruction rate on this Adapter.rw INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.3 |
alarmStateAlarm is enabled or disabled on this adapter. Values: disabled(0),enabled(1)rw INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.4 |
cacheFlushIntervalCache flush interval in seconds for this adapter.ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.5 |
clusterStateCluster is enabled or disabled on this adapter. Values: disabled(0),enabled(1)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.6 |
predFailPollIntervalNumber of seconds between precdictive fail polls on this adapter.rw INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.7 |
intThrottleCountInterrupt throttle active count on this adapter.rw INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.8 |
intThrottleTimeUsInterrupt throttle completion hold time on this adapter.rw INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.9 |
patrolReadRatePatrol Read Rate for this adapter.rw INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.10 |
bgiRateBackground initialization rate for this adapter.rw INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.11 |
spinupDelayNumber of seconds to delay among spinup groups for this adapter.rw INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.12 |
spinupDriveCountMaximum number of drives to spin up at one time for this adapter.rw INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.13 |
coercionModeDrive capacity coercion mode. 0->None; 1->128MB; 2->1GBro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.14 |
nvramSizeNVRAM size in KB for this adapter.ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.15 |
memorySizeMemory size in MB for this adapter.ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.16 |
flashSizeFlash size in MB for this adapter.ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.17 |
vdPresentCountVirtual devices present in this adapter.ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.18 |
vdDegradedCountNumber of virtual devices in this adapter that are criticalro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.19 |
vdOfflineCountNumber of virtual devices in this adapter that are offlinero INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.20 |
pdPresentCountPhysical devices present in this adapter.ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.21 |
pdDiskPresentCountPhysical disk devices present in this adapter.ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.22 |
pdDiskPredFailureCountNumber of disk devices in this adapter that are criticalro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.23 |
pdDiskFailedCountNumber of disk devices in this adapter that are failedro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.24 |
ccRateConsistency Check rate on this Adapter.rw INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.25 |
compatibilityFlagTo inform compatibilities between Applications and FW. 0->incompatible; 1->compatiblero INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.26 |
compatibilityInfoCompatibility Information. Format->(Firmware Forward compatibility flag:Firmware Backward compatibility flag:Firmware version flag:Application Forward compatibility flag:Application Backward compatibility flag:Application version flag)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.1.2.1.27 |
abortCConErrorAbort CC on detecting error is enabled or disabled on this adapter.
Values: No(0),Yes(1),NA(2)rw INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.28 |
copyBackStateCopyBack is enabled or disabled on this adapter.Values: disabled(0),enabled(1)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.29 |
revisionIdentifierBoard revision ID for this Adapter.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.1.2.1.30 |
multipathSupportMultipath is supported or not supported on this adapter.Values: not supported(0),supported(1)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.31 |
ssdSMARTerEnabledCopyback to SSD on SMART error. Values Enabled(0),Disabled(1)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.32 |
enableSpinDownUnconfiguredSpin Down Unconfigured Drives(1), Do Not Spin Down Unconfigured Drives(0)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.33 |
disableSpinDownHotSpareSpin Down Hotspares(0), Do Not Spin Down Hotspares(1)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.34 |
spinDownTimeSpinDownTime in minutesro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.35 |
spinupEnclDriveCountMaximum number of drives that can be spin up in an enclosurero INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.36 |
spinupEnclDelayDelay between drive spin up for drives within an enclosurero INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.37 |
defaultLdPSPolicypower saving policy.values:controller default power saving policy=0, AUTO=1, MAX=2, Max with no cache=6, NONE=255ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.38 |
disableLdPSIntervalLD power savings are disabled for yy hours beginning at disableLdPSTime.ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.39 |
disableLdPSTimeLD power savings shall be disabled at xx minutes from 12:00am.ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.40 |
supportBreakMirror1=Support break mirror operation,0=Do not Support break mirror operationro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.41 |
temperatureROCtemperature of RAID On Chip in Celsiusro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.42 |
temperatureCtrltemperature of controller in Celsiusro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.43 |
preventPIImport1=Prevent import of SAS PI protected logical disks , 0=Not Prevent import of SAS PI protected logical disksro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.44 |
enablePI1 = Enable SAS PI for controller , 0 = Disable SAS PI for controllerro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.45 |
totalSpaceformetadataTotal Space used for MetaDataro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.46 |
useEmergencySpareThis field give the information about Emergency Spare possible Drive types(Uncongiured Good/Global Hotspare)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.1.2.1.47 |
useEmergencySparesforSMARTer1 = Use Emergency spares for SMARTer ,0 = Not Use Emergency spares for SMARTerro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.48 |
supportShieldState1 =Support PD shield state ,0 = Not Support PD shield statero INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.49 |
writeCacheCapable1 = SSC support write caching IOs ,0 = SSC not support write caching IOsro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.50 |
totalCacheSizeThis field give the information about total Size of currently configured SSC,in GBro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.51 |
maximumCacheSizeThis field give the information about maxmium Size of SSC that can yet be configured,in GBro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.52 |
ctrlSasAddrThis field gives the controller SAS addressro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.1.2.1.53 |
domainIdThis field gives the Domain IDro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.1.2.1.54 |
peerControllerStatusThis field gives the Peer controller Statusro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.1.2.1.55 |
maximumControllerNodesThis field gives the HA nodes this FW supportsro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.56 |
incompatibilityDetailsThis field gives the Incompatibility Detailsro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.1.2.1.57 |
topologyTypeThis field gives the Topology Typero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.1.2.1.58 |
supportOnlineFWUpdate1 = Online firmware update is supported, 0 = Online firmware update is not supportedro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.2.1.59 |
adapterInfoTableA List of adapter Entries containing Information/Properties about the adapters on the Controller. SEQUENCE OF AdapterInfoEntry .1.3.6.1.4.1.3582.4.1.4.1.3 |
adapterInfoEntryAn Entry in the adapterInfo table. AdapterInfoEntry .1.3.6.1.4.1.3582.4.1.4.1.3.1 |
adapterID-AITAdapterID for this Adapter.(Unique)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.3.1.1 |
adapterVendorIDPCI Vendor ID for this Adapter.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.1.3.1.2 |
devIDPCI Device ID for this Adapter.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.1.3.1.3 |
subVendorIDPCI Sub-Vendor ID for this adapter.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.1.3.1.4 |
subDevIDPCI Sub-Device ID for this adapter.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.1.3.1.5 |
hostInterfaceHost interface information for this adapter.
Values: N/A(0),PCIX(1),PCIE(2),iSCSI(3),SAS-3G(4)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.3.1.6 |
hostInterfacePortCntPort Count on this adapter.ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.3.1.7 |
hostInterfacePortAddrPort address comma delimitedro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.1.3.1.8 |
devInterfaceMultiple device interface support values separated by space.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.1.3.1.9 |
devInterfacePortCntDevice Port Count on this adapter.ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.3.1.10 |
devInterfacePortAddrDevice Port address comma delimitedro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.1.3.1.11 |
productNameProduct name e.g. MegaRAID SAS-8E, MegaRAID SAS-4X, etc.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.1.3.1.12 |
serialNoController serial numberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.1.3.1.13 |
firmwareVersionFirmware version Format->(Firmware Package Version:Version:Date:Time)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.1.3.1.14 |
driverVersionDriver version Format->(Driver Name:Version)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.1.3.1.15 |
expanderFirmwareVersionExpander firmware version - Not Available if expander is not present on the controllerro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.1.3.1.16 |
lockKeyBindingType of lock key binding. lock key is not bound(0),lock key bound to FW secret key(1), lock key bound to user(2), lock key bound to a TPM(3)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.3.1.17 |
maxDAPdCountSpinup60Maximum number of drives to spinup within 60 sec for direct attached drivesro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.3.1.18 |
adapterSupportInfoTableA List of adapter Entries containing Information/Properties about the adapters on the Controller. SEQUENCE OF AdapterSupportInfoEntry .1.3.6.1.4.1.3582.4.1.4.1.4 |
adapterSupportInfoEntryAn Entry in the adapter table. AdapterSupportInfoEntry .1.3.6.1.4.1.3582.4.1.4.1.4.1 |
adapterID-ASITAdapterID for this Adapter.(Unique)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.4.1.1 |
maxArmsMaximum arms per Virtual Drive supported for this Adapter.ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.4.1.2 |
maxSpansMaximum spans per Virtual Drive supported for this Adapter.ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.4.1.3 |
maxArraysMaximum no of arrays supported for this adapter.ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.4.1.4 |
maxVDsMaximum number of Virtual Drive s supported for this adapter.ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.4.1.5 |
hardwarePresentSupported Hardware on this adapter. bbu(1),alarm(2),nvram(3),uart(4),TPM(5),expander(6). For multiple hw support a space delimited list will appear.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.1.4.1.6 |
maxConcurrentCmdsThe maximum parallel commands supported on this adapter.ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.4.1.7 |
maxSGECountThe maximum Scatter Gather Element count allowed on this adapter.ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.4.1.8 |
maxRequestSizeThe maximum data transfer size in sectors, on this adapter.ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.4.1.9 |
maxLdsPerArrayMax Ld's per array in adapterro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.4.1.10 |
partitionsInDDFMax LD's per Array in configurationro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.4.1.11 |
allowSSDMixInLDallow SAS/SATA SSD mix within an LD. allow(1), not allow(0)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.4.1.12 |
allowMixSSDHDDInLDallow SSD/HDD mix within an LD.allow(1), not allow(0)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.4.1.13 |
adapterOperationsSupportInfoTableA List of adapter Entries containing Information/Properties about the adapters on the Controller. SEQUENCE OF AdapterOperationsSupportInfoEntry .1.3.6.1.4.1.3582.4.1.4.1.5 |
adapterOperationsSupportInfoEntryAn Entry in the adapter table. AdapterOperationsSupportInfoEntry .1.3.6.1.4.1.3582.4.1.4.1.5.1 |
adapterIDAdapterID for this Adapter.(Unique)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.5.1.1 |
rbldRateSupportedRebuilding rate change support for this Adapter. Values: false(0),true(1)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.5.1.2 |
ccRateSupportedConsistency Check rate change support for this Adapter. Values: false(0),true(1)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.5.1.3 |
bgiRateSupportedBackground initialization rate change support for this adapter. Values: false(0),true(1)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.5.1.4 |
reconRateSupportedReconstruction rate change support for this adapter. Values: false(0),true(1)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.5.1.5 |
patrolRateSupportedPatrol read rate change support for this adapter. Values: false(0),true(1)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.5.1.6 |
alarmControlSupportedAlarm control support for this adapter. Values: false(0),true(1)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.5.1.7 |
clusterSupportedCluster support for this adapter. Values: false(0),true(1)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.5.1.8 |
bbuSupportedBBU support for this adapter. Values: false(0),true(1)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.5.1.9 |
spanningAllowedSupportedSpanning support for this adapter. Values: false(0),true(1)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.5.1.10 |
dedicatedHotSparesSupportedDedicated HotSpares support for this adapter. Values: false(0),true(1)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.5.1.11 |
revertibleHotSparesSupportedRevertible HotSpares support for this adapter. Values: false(0),true(1)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.5.1.12 |
foreignConfigImportSupportedSupport foreign config import on this adapter. Values: false(0),true(1)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.5.1.13 |
selfDiagnosticSupportedController supports self diagnostic. Values: false(0),true(1)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.5.1.14 |
allowMixedRedundancyOnArraySupportedAllow different Virtual Disk on the same array to have different redundancy levels.
Values: false(0),true(1)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.5.1.15 |
abortCConErrorSupportedAbort CC on detecting error is supported on this adapter.
Values: No(0),Yes(1)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.5.1.16 |
securitySupportedDisplays the security support. if supported (1) , not supported (0)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.5.1.17 |
supportPIcontrollerDisplays the support PI. 1=LD SAS PI Type 0, 0=LD Not SAS PI Type 0ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.5.1.18 |
bbuInfo OBJECT IDENTIFIER .1.3.6.1.4.1.3582.4.1.4.1.6 |
bbuNumberThe present number of rows in the BBU Table.ro Gauge .1.3.6.1.4.1.3582.4.1.4.1.6.1 |
bbuTableA List of BBU Entries containing Information/Properties about the BBU. SEQUENCE OF BBUEntry .1.3.6.1.4.1.3582.4.1.4.1.6.2 |
bbuEntryAn Entry in the BBU table. BBUEntry .1.3.6.1.4.1.3582.4.1.4.1.6.2.1 |
bbuIDBBUID for this BBU.(Unique)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.1 |
batteryTypeBBU Type.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.2 |
nextLearnTimeTime of next scheduled learn cycle (seconds past 1/1/2000)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.3 |
absStateOfChargePredicted remaining capacity expressed as % of DesignCapacity() (0-100). Value of -1 means not supportedro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.4 |
fullChargeCapacityPredicted pack capacity when it is fully charged in joulesro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.5 |
averageEmptyTimeOne-minute rolling average of the predicted remaining battery life. Value of -1 means not supportedro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.6 |
cycleCountNumber of charge cycles the battery has experienced. Value of -1 means not supportedro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.7 |
firmwareStatusCondition of battery in following order:
packMissing(0/1)
voltageLow(0/1)
temperatureHigh(0/1)
chargeActive(0/1)
dischargeActive(0/1)
learnCycleRequested(0/1)
learnCycleActive(0/1)
learnCycleFailed(0/1)
learnCycleTimeout(0/1)
i2cErrorsDetected(0/1)
noSpace(0/1)
predictiveFailure(0/1)
premiumFeatureReqd(0/1)
microcodeUpdateReqd(0/1)
Only enabled(1) values will be shownro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.8 |
voltageAccurate battery terminal voltage in mV, resolution of 1mVro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.9 |
autoLearnPeriodTime (in seconds) between learn cycles (0 to disable auto learn)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.10 |
relStateOfChargePredicted remaining capacity expressed as % of FullChargeCapacity() (0-100). Value of -1 means not supportedro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.11 |
capacityRemainPredicted charge or energy remaining in the battery in joulesro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.12 |
runTimeToEmptyRelative gain or loss in remaining life in response to change in power policy represent in minute. Value of -1 means not supportedro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.13 |
avgTimeToFullOne-minute rolling average of predicted remaining time to full charge. Value of -1 means not supportedro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.14 |
errorMarginExpected margin of error (%) in charge calculation (2-100). Value of -1 means not supportedro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.15 |
temperatureBattery temperature in degree Centigradero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.16 |
mfgNameBattery manufacturer's namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.17 |
deviceNameBattery namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.18 |
serialNumberBattery serialNumberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.19 |
chargerStatusBattery charger status. Values: N/A(-1), off(0), complete(1), progress(2)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.20 |
adpIDThe adapter id where BBU is attachedro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.21 |
remainingCapAlarmRemaining capacity to alarm. Value of -1 means not supportedro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.22 |
remainingTimeAlarmRemaining time to alarm. Value of -1 means not supportedro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.23 |
bbu-currentCurrent(In mA) being supplied (or accepted) through the battery terminalsro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.24 |
gasGaugeStatusGas gauge statusro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.25 |
bbuFRUbbu FRUro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.26 |
batteryReplacementThis property denotes whether the Battery needs to be replaced or not.1 =battery needs to be replaced ,0 =battery needs not to be replacedro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.27 |
bbuRetentiontimeThe total no. of hours the battery can support the current capacity reserve. Undefined(0),48 hours+(>48),the exact no of hours(<=48)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.28 |
bbuStateThis property gives the Information about BBU state. Operational = if BBU is working fine, Non-Operational = if BBU is not working finero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.29 |
memoryModuleFRUtmm FRUro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.30 |
bbuFirmwareVersionBattery Firmware Versionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.31 |
commonDeviceInfoTableA List of general Physical Disk info SEQUENCE OF CommonDeviceInfoEntry .1.3.6.1.4.1.3582.4.1.4.1.7 |
commonDeviceInfoEntryAn Entry in the CommonDeviceInfo table. CommonDeviceInfoEntry .1.3.6.1.4.1.3582.4.1.4.1.7.1 |
adapterID-CDITUnique adapter IDro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.7.1.1 |
forceOnlinePhysical drive force Online operation support. Values: notSupported(0), supported(1)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.7.1.2 |
forceOfflinePhysical drive force Offline operation support. Values: notSupported(0), supported(1)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.7.1.3 |
forceRebuildPhysical drive force Rebuild operation support. Values: notSupported(0), supported(1)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.7.1.4 |
supportsSASSAS physical drive support. Values: notSupported(0), supported(1)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.7.1.5 |
supportsSATASATA physical drive support. Values: notSupported(0), supported(1)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.7.1.6 |
allowMixInEnclosureMix InEnclosure support. Values: notSupported(0), supported(1)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.7.1.7 |
allowMixInVDMixInVIRTUALDRIVE support. Values: notSupported(0), supported(1)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.7.1.8 |
allowSataInClusterSataInCluster support. Values: notSupported(0), supported(1)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.7.1.9 |
setPowerStateForCfgFW requires application to set power state before configuration changes. Required(1), Not Required(0)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.7.1.10 |
commonVirtualDeviceInfoTableA List of general Virtual Drive info SEQUENCE OF CommonVirtualDeviceInfoEntry .1.3.6.1.4.1.3582.4.1.4.1.8 |
commonVirtualDeviceInfoEntryAn Entry in the CommonVirtualDeviceInfo table. CommonVirtualDeviceInfoEntry .1.3.6.1.4.1.3582.4.1.4.1.8.1 |
adapterID-CVDITUnique adapter IDro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.8.1.1 |
supportedReadPolicyRead policy support. Values: false(0),true(1)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.8.1.2 |
supportedWritePolicyWrite policy support. Values: false(0),true(1)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.8.1.3 |
supportedIOPolicyIO policy support. Values: false(0),true(1)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.8.1.4 |
supportedAccessPolicyAccess policy support. Values: false(0),true(1)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.8.1.5 |
supportedMinSizeMinimum stripe size supported. 0(512B),1(1K),2(2K),3(4K),4(8K),5(16K),6(32),7(64K),8(128K) ... 11(1MB) etcro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.8.1.6 |
supportedMaxSizeMaximum stripe size supported. 0(512B),1(1K),2(2K),3(4K),4(8K),5(16K),6(32),7(64K),8(128K) ... 11(1MB) etcro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.8.1.7 |
ldbbm1=LD bad block management is enabled, 0=LD bad block management is not enabledro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.8.1.8 |
adapterStatusSupportInfoTableA List of adapter Entries containing Information/Properties about the adapters on the Controller. SEQUENCE OF AdapterStatusSupportInfoEntry .1.3.6.1.4.1.3582.4.1.4.1.9 |
adapterStatusSupportInfoEntryAn Entry in the adapter table. AdapterStatusSupportInfoEntry .1.3.6.1.4.1.3582.4.1.4.1.9.1 |
adapterID-ASSITAdapterID for this Adapter.(Unique)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.9.1.1 |
lockKeyAssignedLock key Assigned support for this Adapter. Values: false(0),true(1)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.9.1.2 |
lockKeyFailedlock Key Failed support for this Adapter. Values: false(0),true(1)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.9.1.3 |
lockKeyNotBackeduplock Key Not Backedup support for this Adapter. Values: false(0),true(1)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.9.1.4 |
biosNotDetectedbios Not Detected support for this Adapter. Values: false(0),true(1)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.9.1.5 |
cacheIsPinned1=controller cache is pinned for missing or offline LDsro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.9.1.6 |
adapterLdOperationSupportInfoTableA List of adapter Entries containing Information/Properties about the adapters on the Controller. SEQUENCE OF AdapterLdOperationSupportInfoEntry .1.3.6.1.4.1.3582.4.1.4.1.10 |
adapterLdOperationSupportInfoEntryAn Entry in the adapter table. AdapterLdOperationSupportInfoEntry .1.3.6.1.4.1.3582.4.1.4.1.10.1 |
adapterID-ALSITAdapterID for this Adapter.(Unique)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.10.1.1 |
allowCtrlEncryptionif it is set (1) supports controller encryptionro INTEGER .1.3.6.1.4.1.3582.4.1.4.1.10.1.2 |
device OBJECT IDENTIFIER .1.3.6.1.4.1.3582.4.1.4.2 |
physicalDriveInfo OBJECT IDENTIFIER .1.3.6.1.4.1.3582.4.1.4.2.1 |
pdNumberThe present number of rows in the physical drive table.ro Gauge .1.3.6.1.4.1.3582.4.1.4.2.1.1 |
physicalDriveTableA List of physical drive Entries containing Information/Properties about the drives SEQUENCE OF PhysicalDriveEntry .1.3.6.1.4.1.3582.4.1.4.2.1.2 |
physicalDriveEntryAn Entry in the Device Table. PhysicalDriveEntry .1.3.6.1.4.1.3582.4.1.4.2.1.2.1 |
pdIndexThe unique IDro INTEGER .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.1 |
physDevIDThe Device IDro INTEGER .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.2 |
oemSupportedIs the drive supported by the OEM (OEM-specific checks). Values: notSupported(1), supported(0)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.3 |
scsiDevTypeType of this Device.
Values: disk(0),tape(1),printer(2),processor(3),cdrom(5),scanner(6),optical(7),enclosure(13),dvd(10),unknown(31)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.4 |
connectedAdapterPortAdapter port(s) to which the device is connected.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.5 |
deviceSpeedMaximum supported speed. Values: speed-unknown(0),speed-1p5G(1),speed-3G(2),speed-6G(3)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.6 |
mediaErrCountError count of the devicero INTEGER .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.7 |
otherErrCountOther error count of the devicero INTEGER .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.8 |
predFailCountPredictive fail count of the devicero INTEGER .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.9 |
pdStateFirmware's interpretation of drive state.
Values: unconfigured-good(0),unconfigured-bad(1),hot-spare(2),offline(16),failed(17),rebuild(20),online(24),copyback(32),system(64),UNCONFIGURED-SHIELDED(128),HOTSPARE-SHIELDED(130),CONFIGURED-SHIELDED(144)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.10 |
disabledForRemovalIf true, drive is ready for removal. Values: false(0),true(1)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.11 |
linkSpeedNegotiated link speed. Values: speed-unknown(0),speed-1p5G(1),speed-3G(2),speed-6G(3)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.12 |
pdSupportFlags1st Byte:forcedPDGUID(0/1),2nd Byte:inVD(0/1),3rd Byte:isGlobalSpare(0/1),4th Byte:isSpare(0/1),5th Byte:isForeign(0/1),6th Byte:intf(0-Unknown, 1-parallel SCSI, 2-SAS, 3-SATA, 4-FC).A comma delimited list will appear.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.13 |
sasAddrDevice SAS addresses. Comma separeted for multiple addressro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.14 |
rawSizeSize(MB) before COD and coercionro INTEGER .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.15 |
nonCoercedSizeSize(MB) after COD is reserved but before coercionro INTEGER .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.16 |
coercedSizeSize(MB) after COD is reserved and after coercionro INTEGER .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.17 |
enclDeviceIdEnclosure's device Id (in decimal); if device is not within enclosure value is -1ro INTEGER .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.18 |
enclIndexFirmware internal enclosure indexro INTEGER .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.19 |
slotNumberSlot number of this drive, if the Physical Disk is part of an enclosure then -1ro INTEGER .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.20 |
operationProgressOperation progress in %. e.g. Rebuild progress is 10%ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.21 |
adpID-PDTController id where this Physical Drive is attachedro INTEGER .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.22 |
operationSupportMakeOnline,MakeOffline,MakeFailed,MakeBad,MakeUncofigured,
MakeSpare,RemoveSpare,replaceMissing,markMissing,startRebuild,
stopRebuild,locate,pdclear,foreignImportNotAllowed,ForeignImportAllowed,
startCopyBack,stopCopyBack,fwDownloadNotAllowed,fwDownloadAllowed,makeSystemro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.23 |
pdVendorIDVendor IDro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.24 |
pdProductIDProduct IDro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.25 |
pdFwversionPD firmware versionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.26 |
diskTypeType of the disk : 0-Unknown, 1-parallel SCSI, 2-SAS, 3-SATA, 4-FCro INTEGER .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.27 |
partnerDevIdIf drive is in an enclosure with dual paths,This is Partner Device ID.
In all other cases INVALID(-1)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.28 |
mediatypeMedia Type HDD(0),SSD(1),Solid state flash module(2)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.29 |
powerStatePower condition of the device. Values are device is active(0),device is stopped(1),device is transitioning between power states(255)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.30 |
secured1=drive is secured, 0=not securedro INTEGER .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.31 |
locked1=drive is locked, 0=unlockedro INTEGER .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.32 |
foreign1=drive is secured by a foreign lock key, 0=drive is not secured by a foreign lock keyro INTEGER .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.33 |
oemCertifiedIs the drive certified by the OEM (OEM-specific checks). Values: notCertified(1), Certified(0)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.34 |
foreignImportNotAllowed1=Drive is not allowed foreignImport operation, 0=Drive is allowed foreignImport operationro INTEGER .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.35 |
pdTemperaturePhysical Drive temperature in Celsiusro INTEGER .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.36 |
pdSerialNumberPhysical Drives serial numberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.37 |
piEligibleProtection Information eligibility.1=drive can be used for PD Enabled LD , 0=drive can't be used for PD Enabled LDro INTEGER .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.38 |
piTypeSAS Protection Information Type .No SAS protection type used(0) ,SAS PI Type 1(1) ,SAS PI Type 2(2) ,SAS PI Type 3(3) ,Reserved SAS PI Type 4(4) ,Reserved SAS PI Type 5(5) ,Reserved SAS PI Type 6(6) ,Reserved SAS PI Type 7(7).ro INTEGER .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.39 |
piFormattedformatted for PI information. 1=drive is formatted for PI information, 0=no PI data.ro INTEGER .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.40 |
userDataBlockSizeNumber of bytes of user data in LBAro INTEGER .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.41 |
commissionedSpareYes = this PD is a commissioned spare, No = this PD is not a commissioned spare.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.42 |
emergencySpareEligible = this PD is a emergency spare, Ineligible = this PD is not a emergency spare.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.43 |
shieldCounterHow many times the shield diagnostics was run before it was marked failedro INTEGER .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.44 |
shieldDiagCompletionTimeLast successful Diagnostics completion time. 0 is N/Aro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.45 |
ineligibleForSSCDWhether PD cannot be used for an SSCD. PD can not be used for an SSCD(1), PD can be used for an SSCD(0)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.46 |
ineligibleForLdWhether PD cannot be used for a regular LD. PD can not be used for a regular LD(1), PD can be used for a regular LD(0)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.2.1.2.1.47 |
virtualDevice OBJECT IDENTIFIER .1.3.6.1.4.1.3582.4.1.4.3 |
vdInfo OBJECT IDENTIFIER .1.3.6.1.4.1.3582.4.1.4.3.1 |
vdNumbersThe present number of rows in the virtualDrive table.ro Gauge .1.3.6.1.4.1.3582.4.1.4.3.1.1 |
virtualDriveTableA List of Virtual Drives Entries containing Information/Properties about the virtualDrive. SEQUENCE OF VirtualDriveEntry .1.3.6.1.4.1.3582.4.1.4.3.1.2 |
virtualDriveEntryAn Entry in the virtualDrive Table. VirtualDriveEntry .1.3.6.1.4.1.3582.4.1.4.3.1.2.1 |
virtualDevIDThe unique Virtual Drives IDro INTEGER .1.3.6.1.4.1.3582.4.1.4.3.1.2.1.1 |
sizeTotal size in MB of the drivero INTEGER .1.3.6.1.4.1.3582.4.1.4.3.1.2.1.2 |
clusterOwnerDeviceIdVD owner's device Idro INTEGER .1.3.6.1.4.1.3582.4.1.4.3.1.2.1.3 |
targetIdVirtual Drive target id (i.e. 0 to 63)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.3.1.2.1.4 |
stateThe Device state: Values: offline(0),partially-degraded(1),degraded(2),optimal(3)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.3.1.2.1.5 |
nameVirtual Drive namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.3.1.2.1.6 |
defaultCachePolicyDefault cache policy settings. Values: WriteBack, WriteThrough, ReadAdaptive, ReadAhead, ReadAheadNone, Cached, Direct, Write Cache OK if Bad BBU, No Write Cache if Bad BBU.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.3.1.2.1.7 |
accessPolicyAccess policy settings. Values: access-rw(0), access-read-only(2), access-blocked(3)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.3.1.2.1.8 |
diskCachePolicyPhysical disk cache policy. Values: unchanged(0),enable(1),disable(2)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.3.1.2.1.9 |
bgiStateDisable/Enable Back Groung Initialization on this Virtual Drive. Values: disable(1),enable(0)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.3.1.2.1.10 |
prlPrimay raid level. Values: 0(RAID-0), 1(RAID-1), 3(RAID-3), 4(RAID-4), 5(RAID-5), 6(RAID-6),15(Single Disk or JBOD),
17(RAID-1E), 21(RAID-5E), 31(Concatenation),37(RAID-5EEE)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.3.1.2.1.11 |
rLQRaid level qualifierro INTEGER .1.3.6.1.4.1.3582.4.1.4.3.1.2.1.12 |
sRLSecondary raid level. Values: 0(Stripped), 1(Mirrored), 2(Concatenated), 3(Spanned)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.3.1.2.1.13 |
stripeSizeStripe Size. 0(512B),1(1K),2(2K),3(4K),4(8K),5(16K),6(32),7(64K),8(128K) ... 11(1MB) etcro INTEGER .1.3.6.1.4.1.3582.4.1.4.3.1.2.1.14 |
numDrivesNumber of drivers per spanro INTEGER .1.3.6.1.4.1.3582.4.1.4.3.1.2.1.15 |
spanDepthNumber of spans. If only one array then it is considered as 1 spanro INTEGER .1.3.6.1.4.1.3582.4.1.4.3.1.2.1.16 |
initState0=no init, 1=quick init, 2=full initro INTEGER .1.3.6.1.4.1.3582.4.1.4.3.1.2.1.17 |
vdOperationProgressProgress % for an operation / No operation in progressro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.3.1.2.1.18 |
currentCachePolicyCache policy settings. Values:WriteBack, WriteThrough, ReadAdaptive, ReadAhead, ReadAheadNone, Cached, Direct, Write Cache OK if Bad BBU, No Write Cache if Bad BBU.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.3.1.2.1.19 |
adapterID-VDTAdapter IDro INTEGER .1.3.6.1.4.1.3582.4.1.4.3.1.2.1.20 |
encryptionTypelogical drive encryption type. Values No Encryption(0), FDE drive encryption(1), Controller-based encryption(2)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.3.1.2.1.21 |
vdOperationSupportstartFGI,stopFGI,startCC,stopCC,startRecon,deleteLDro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.3.1.2.1.22 |
badBlocksExist0 = LD bad block table is empty, 1 = LD bad block table is not emptyro INTEGER .1.3.6.1.4.1.3582.4.1.4.3.1.2.1.23 |
defaultPSPolicyPower Savings policy set for this LD.Values:controller default power saving policy=0, AUTO=1, MAX=2, MAX with no cache=6, NONE=255ro INTEGER .1.3.6.1.4.1.3582.4.1.4.3.1.2.1.24 |
currentPSPolicyPower Savings policy set for this LD.Values:controller default power saving policy=0, AUTO=1, MAX=2, MAX with no cache=6, NONE=255ro INTEGER .1.3.6.1.4.1.3582.4.1.4.3.1.2.1.25 |
breakMirrorBreak Mirror Policy set for this LD.Values:1=break mirror is allowed, 0=break mirror not is allowedro INTEGER .1.3.6.1.4.1.3582.4.1.4.3.1.2.1.26 |
joinMirrorJoin Mirror policy set for this LD.Values:1=join mirror is allowed, 0=join mirror not is allowedro INTEGER .1.3.6.1.4.1.3582.4.1.4.3.1.2.1.27 |
mirrorPdInfoMirror Info Property give the Information about mirror of PD and PD state respectively.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.3.1.2.1.28 |
vdPiTypeInformation about logical drive protection type . No SAS protection type used(0) ,SAS PI Type 1(1) ,SAS PI Type 2(2) ,SAS PI Type 3(3) ,Reserved SAS PI Type 4(4) ,Reserved SAS PI Type 5(5) ,Reserved SAS PI Type 6(6) ,Reserved SAS PI Type 7(7) ,SAS PI Type 8(8).ro INTEGER .1.3.6.1.4.1.3582.4.1.4.3.1.2.1.29 |
mirrorDataSizeTotal Space used for mirrorData or Parity informationro INTEGER .1.3.6.1.4.1.3582.4.1.4.3.1.2.1.30 |
cacheCadeType0= Non-CacheCade VD, 1= CacheCade Type is Read & Write, 2= CacheCade Type is Read only, 3= R1-ECro INTEGER .1.3.6.1.4.1.3582.4.1.4.3.1.2.1.31 |
currentWritePolicyCurrent write policy settings. Values: WriteBack, WriteThrough, AlwaysWriteBackro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.3.1.2.1.32 |
defaultWritePolicyDefault write policy settings. Values: WriteBack, WriteThrough, AlwaysWriteBackro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.3.1.2.1.33 |
associatedVDThis property gives the Information about VD is Cached or VD is not cached.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.3.1.2.1.34 |
hostAccessPolicyThis property gives the Host Access Policyro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.3.1.2.1.35 |
guidThis property gives the LD GUID.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.3.1.2.1.36 |
vdSpanInfoTableA List of span Entries containing Information/Properties vd span. SEQUENCE OF VDSpanInfoEntry .1.3.6.1.4.1.3582.4.1.4.3.1.3 |
vdSpanInfoEntryAn Entry in the vdSpan Table. VDSpanInfoEntry .1.3.6.1.4.1.3582.4.1.4.3.1.3.1 |
spanIDThe unique Span IDro INTEGER .1.3.6.1.4.1.3582.4.1.4.3.1.3.1.1 |
vdID-VSITThe Virtual Device IDro INTEGER .1.3.6.1.4.1.3582.4.1.4.3.1.3.1.2 |
startBlockSpan physical disk starting blockro INTEGER .1.3.6.1.4.1.3582.4.1.4.3.1.3.1.3 |
numBlocksSpan physical disk block countro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.3.1.3.1.4 |
vdSpanArrayRefArray reference (index)ro INTEGER .1.3.6.1.4.1.3582.4.1.4.3.1.3.1.5 |
adapterID-VSITAdapter IDro INTEGER .1.3.6.1.4.1.3582.4.1.4.3.1.3.1.6 |
arrayInfo OBJECT IDENTIFIER .1.3.6.1.4.1.3582.4.1.4.3.4 |
arrayNumberThe present number of rows in the array table.ro Gauge .1.3.6.1.4.1.3582.4.1.4.3.4.1 |
arrayTableA List of array Entries containing Information/Properties about the arrays. SEQUENCE OF ArrayEntry .1.3.6.1.4.1.3582.4.1.4.3.4.2 |
arrayEntryAn Entry in the array Table. ArrayEntry .1.3.6.1.4.1.3582.4.1.4.3.4.2.1 |
arrayIDThe unique array IDro INTEGER .1.3.6.1.4.1.3582.4.1.4.3.4.2.1.1 |
arraySizeSize in MBro INTEGER .1.3.6.1.4.1.3582.4.1.4.3.4.2.1.2 |
arrayNumDrivesNumber of drives for this arrayro INTEGER .1.3.6.1.4.1.3582.4.1.4.3.4.2.1.3 |
arrayRefTag for the arrayro INTEGER .1.3.6.1.4.1.3582.4.1.4.3.4.2.1.4 |
pdListSpace separated Physical Drive identification. e.g. {devID devID devID} etcro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.3.4.2.1.5 |
adapterID-ATAdapter ID.ro INTEGER .1.3.6.1.4.1.3582.4.1.4.3.4.2.1.6 |
spareInfo OBJECT IDENTIFIER .1.3.6.1.4.1.3582.4.1.4.3.5 |
spareDevNumberThe present number of rows in the sparepool table.ro Gauge .1.3.6.1.4.1.3582.4.1.4.3.5.1 |
spareTableA List of sparepool Entries containing Information/Properties about the spare drive SEQUENCE OF SpareEntry .1.3.6.1.4.1.3582.4.1.4.3.5.2 |
spareEntryAn Entry in the sparepool Table. SpareEntry .1.3.6.1.4.1.3582.4.1.4.3.5.2.1 |
spareIDThe unique Device IDro INTEGER .1.3.6.1.4.1.3582.4.1.4.3.5.2.1.1 |
deviceIdentificationThe unique Device IDro INTEGER .1.3.6.1.4.1.3582.4.1.4.3.5.2.1.2 |
spareTypeSpare type. isDedicated(0/1)isRevertible(0/1)isEnclAffinity(0/1). 1 implies particular feature is enable and 0 represent feature is disable.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.3.5.2.1.3 |
arrayCountThe number of arrays to which the Physical Drive can be dedicatedro INTEGER .1.3.6.1.4.1.3582.4.1.4.3.5.2.1.4 |
arrayIDsComma separated array ids. e.g. 2,4,5 etcro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.4.3.5.2.1.5 |
adapterID-STAdapter ID.ro INTEGER .1.3.6.1.4.1.3582.4.1.4.3.5.2.1.6 |
enclosureInfo OBJECT IDENTIFIER .1.3.6.1.4.1.3582.4.1.5 |
enclosureNumberThe present number of rows in the enclosure table.ro Gauge .1.3.6.1.4.1.3582.4.1.5.1 |
enclosureTableA List of Enclosure Entries containing Information/Properties about the enclosures in the system. SEQUENCE OF EnclosureEntry .1.3.6.1.4.1.3582.4.1.5.2 |
enclosureEntryAn Entry in the enclosure table. EnclosureEntry .1.3.6.1.4.1.3582.4.1.5.2.1 |
enclosureIDEnclosureID for this enclosure.(Unique)ro INTEGER .1.3.6.1.4.1.3582.4.1.5.2.1.1 |
deviceIdEnclosure device Id.ro INTEGER .1.3.6.1.4.1.3582.4.1.5.2.1.2 |
enclosureIndexFirmware internal enclosure indexro INTEGER .1.3.6.1.4.1.3582.4.1.5.2.1.3 |
slotCountNumber of slotsro INTEGER .1.3.6.1.4.1.3582.4.1.5.2.1.4 |
psCountNumber of power suppliesro INTEGER .1.3.6.1.4.1.3582.4.1.5.2.1.5 |
fanCountNumber of fansro INTEGER .1.3.6.1.4.1.3582.4.1.5.2.1.6 |
tempSensorCountNumber of temperature sensorsro INTEGER .1.3.6.1.4.1.3582.4.1.5.2.1.7 |
alarmCountNumber of alarmsro INTEGER .1.3.6.1.4.1.3582.4.1.5.2.1.8 |
simCountNumber of SIM modulesro INTEGER .1.3.6.1.4.1.3582.4.1.5.2.1.9 |
isFaultEnclosure has entered a FAULT state or not. Values: false(0),true(1)ro INTEGER .1.3.6.1.4.1.3582.4.1.5.2.1.10 |
pdCountNumber of physical drives presentro INTEGER .1.3.6.1.4.1.3582.4.1.5.2.1.11 |
pdIdsPhysical drive deviceIds space separated.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.5.2.1.12 |
adapterID-ETAdapter ID.ro INTEGER .1.3.6.1.4.1.3582.4.1.5.2.1.13 |
pdCountSpinup60Number of drives that can spun up in 60 sec.ro INTEGER .1.3.6.1.4.1.3582.4.1.5.2.1.14 |
enclosureTypeInformation about type of enclosure : 0= UNKNOWN ,1= SAFTE ,2=SES ,3= SGPIO.ro INTEGER .1.3.6.1.4.1.3582.4.1.5.2.1.15 |
enclFirmwareVersionInformation about enclosure FW Versionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.5.2.1.16 |
enclSerialNumberEnclosure Serial Numberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.5.2.1.17 |
vendorIDEnclosure Vendor IDro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.5.2.1.18 |
productIDEnclosure Product IDro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.5.2.1.19 |
eSMSerialNumberIBM Enclosure ESM Serial Numberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.5.2.1.20 |
eSMFRUInformation about IBM Enclosure ESM FRUro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.5.2.1.21 |
enclosureZoningModeEnclosure IBM Zoning Modero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.5.2.1.22 |
eSMFRUPartInfoInformation about IBM Enclosure ESM FRU Partro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.5.2.1.23 |
enclosureFanTableA List of fan Entries containing Information/Properties about the enclosureFan. SEQUENCE OF EnclosureFanEntry .1.3.6.1.4.1.3582.4.1.5.3 |
enclosureFanEntryAn Entry in the enclosureFan table. EnclosureFanEntry .1.3.6.1.4.1.3582.4.1.5.3.1 |
fanIDID for this EnclosureFan.(Unique)ro INTEGER .1.3.6.1.4.1.3582.4.1.5.3.1.1 |
enclosureIdEnclosure ID where the fan is attachedro INTEGER .1.3.6.1.4.1.3582.4.1.5.3.1.2 |
fanStatusstatus of the fanro Enumeration .1.3.6.1.4.1.3582.4.1.5.3.1.3 |
enclosureSlotTableA List of slot Entries containing Information/Properties about the enclosure slots. SEQUENCE OF EnclosureSlotEntry .1.3.6.1.4.1.3582.4.1.5.4 |
enclosureSlotEntryAn Entry in the enclosureSlot table. EnclosureSlotEntry .1.3.6.1.4.1.3582.4.1.5.4.1 |
slotIDID for this slot.(Unique)ro INTEGER .1.3.6.1.4.1.3582.4.1.5.4.1.1 |
enclosureId-ESTenclosure IDro INTEGER .1.3.6.1.4.1.3582.4.1.5.4.1.2 |
slotStatusstatus of the devicero Enumeration .1.3.6.1.4.1.3582.4.1.5.4.1.3 |
enclosurePowerSupplyTableA List of powerSupply Entries containing Information/Properties about the enclosure powerSupply SEQUENCE OF EnclosurePowerSupplyEntry .1.3.6.1.4.1.3582.4.1.5.5 |
enclosurePowerSupplyEntryAn Entry in the powerSupply table. EnclosurePowerSupplyEntry .1.3.6.1.4.1.3582.4.1.5.5.1 |
powerSupplyIDID for this powerSupply.(Unique)ro INTEGER .1.3.6.1.4.1.3582.4.1.5.5.1.1 |
enclosureId-EPSTEnclosure id for the powerSupplyro INTEGER .1.3.6.1.4.1.3582.4.1.5.5.1.2 |
powerSupplyStatusStatus of the power Supplyro Enumeration .1.3.6.1.4.1.3582.4.1.5.5.1.3 |
enclosureTempSensorTableA List of TempSensor Entries containing Information/Properties about the enclosure TempSensor SEQUENCE OF EnclosureTempSensorEntry .1.3.6.1.4.1.3582.4.1.5.6 |
enclosureTempSensorEntryAn Entry in the adapter table. EnclosureTempSensorEntry .1.3.6.1.4.1.3582.4.1.5.6.1 |
tempSensorIDID for this TempSensor.(Unique)ro INTEGER .1.3.6.1.4.1.3582.4.1.5.6.1.1 |
enclosureId-ETSTEnclosure id for this TempSensorro INTEGER .1.3.6.1.4.1.3582.4.1.5.6.1.2 |
tempSensorStatusStatus of the Temparature Sensorro Enumeration .1.3.6.1.4.1.3582.4.1.5.6.1.3 |
enclosureTemperatureCurrent temperature in degree Centigradero INTEGER .1.3.6.1.4.1.3582.4.1.5.6.1.4 |
enclosureAlarmTableA List of Alarm Entries containing Information/Properties about enclosure Alarms SEQUENCE OF EnclosureAlarmEntry .1.3.6.1.4.1.3582.4.1.5.7 |
enclosureAlarmEntryAn Entry in the enclosureAlarm table. EnclosureAlarmEntry .1.3.6.1.4.1.3582.4.1.5.7.1 |
alarmIDID for this Alarm.(Unique)ro INTEGER .1.3.6.1.4.1.3582.4.1.5.7.1.1 |
enclosureId-EATEnclosure id where the Alarm is attachedro INTEGER .1.3.6.1.4.1.3582.4.1.5.7.1.2 |
alarmStatusStatus of the alarmro Enumeration .1.3.6.1.4.1.3582.4.1.5.7.1.3 |
enclosureSIMTableA List of SIM Entries containing Information/Properties about enclosure SIMs SEQUENCE OF EnclosureSIMEntry .1.3.6.1.4.1.3582.4.1.5.8 |
enclosureSIMEntryAn Entry in the enclosureSIM table. EnclosureSIMEntry .1.3.6.1.4.1.3582.4.1.5.8.1 |
simIDID for this SIM.(Unique)ro INTEGER .1.3.6.1.4.1.3582.4.1.5.8.1.1 |
enclosureId-ESITInclosure ID where the SIM is attachedro INTEGER .1.3.6.1.4.1.3582.4.1.5.8.1.2 |
simStatusStatus of the SIMro Enumeration .1.3.6.1.4.1.3582.4.1.5.8.1.3 |
adapterTraps OBJECT IDENTIFIER .1.3.6.1.4.1.3582.4.1.6 |
atAdpNumberAdapter ID for which Trap is generated.ro INTEGER .1.3.6.1.4.1.3582.4.1.6.1001 |
atAlarmStateAlarm disabled/enabled. Values: disabled(0),enabled(1)ro INTEGER .1.3.6.1.4.1.3582.4.1.6.1002 |
atRateBGI/Check Consistency/Rebuild/Patrol Read/Reconstruction Ratero INTEGER .1.3.6.1.4.1.3582.4.1.6.1003 |
atFlashImageNameFlash Image Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.6.1004 |
atIDIDro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.6.1005 |
clustCtrlpropResetResetting controller propertyro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.6.1006 |
vdTraps OBJECT IDENTIFIER .1.3.6.1.4.1.3582.4.1.7 |
vdNumbervd Target ID for which Trap is generated.ro INTEGER .1.3.6.1.4.1.3582.4.1.7.1101 |
vdSeqvd Sequence no for which Trap is generated.ro INTEGER .1.3.6.1.4.1.3582.4.1.7.1102 |
vdProgprogress %ro INTEGER .1.3.6.1.4.1.3582.4.1.7.1103 |
vdCachePolicyChangeReasonVD cache policy.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.7.1104 |
vdNewStateVirtual Drive state. Values are: offline(0),partially-degraded(1),degraded(2),optimal(3)ro INTEGER .1.3.6.1.4.1.3582.4.1.7.1105 |
vdOldStateVirtual Drive state. Values are: offline(0),partially-degraded(1),degraded(2),optimal(3)ro INTEGER .1.3.6.1.4.1.3582.4.1.7.1106 |
isRemoteHA cluster locale: 0=local, 1=remote (at peer)ro INTEGER .1.3.6.1.4.1.3582.4.1.7.1107 |
pdTraps OBJECT IDENTIFIER .1.3.6.1.4.1.3582.4.1.8 |
pdIDDevice ID for which Trap is generated.ro INTEGER .1.3.6.1.4.1.3582.4.1.8.1201 |
pdEncIndexEnclosure index(0 means not within an enclosure) for which Trap is generated.ro INTEGER .1.3.6.1.4.1.3582.4.1.8.1202 |
pdSlotNoSlot no for the enclosurero INTEGER .1.3.6.1.4.1.3582.4.1.8.1203 |
pdNewStatePhysical Drive state. Values are: unconfigured-good(0),unconfigured-bad(1),hot-spare(2),offline(16),failed(17),rebuild(20),online(24),copyback(32),system(64)ro INTEGER .1.3.6.1.4.1.3582.4.1.8.1204 |
pdOldStatePhysical Drive state. Values are: unconfigured-good(0),unconfigured-bad(1),hot-spare(2),offline(16),failed(17),rebuild(20),online(24),copyback(32),system(64)ro INTEGER .1.3.6.1.4.1.3582.4.1.8.1205 |
pdEnclDeviceIdEnclosure Device ID for which Trap is generated.ro INTEGER .1.3.6.1.4.1.3582.4.1.8.1206 |
pdSASAddDevice SAS addresses. Comma separeted for multiple address.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.8.1207 |
pdPathPD path.ro INTEGER .1.3.6.1.4.1.3582.4.1.8.1208 |
pdFRUPD FRU for which trap is generated.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.3582.4.1.8.1209 |
pdNewPowerStateNew Power Status Of the Device.Values are device is active(0),device is stopped(1),device is transitioning between power states(255)ro INTEGER .1.3.6.1.4.1.3582.4.1.8.1210 |
enclTraps OBJECT IDENTIFIER .1.3.6.1.4.1.3582.4.1.9 |
atPortProt no.ro INTEGER .1.3.6.1.4.1.3582.4.1.9.1301 |
onPHYPHY noro INTEGER .1.3.6.1.4.1.3582.4.1.9.1302 |
pciTraps OBJECT IDENTIFIER .1.3.6.1.4.1.3582.4.1.10 |
pciVendorIdPCI VendorIDro INTEGER .1.3.6.1.4.1.3582.4.1.10.1501 |
pciDeviceIdPCI Device IDro INTEGER .1.3.6.1.4.1.3582.4.1.10.1502 |
pciSubVendorIdPCI SubVendorIDro INTEGER .1.3.6.1.4.1.3582.4.1.10.1503 |
pciSubDeviceIdPCI SubDeviceIDro INTEGER .1.3.6.1.4.1.3582.4.1.10.1504 |
copyrightInfo OBJECT IDENTIFIER .1.3.6.1.4.1.3582.4.1.11 |
copyrightLSI Corporationro DisplayString .1.3.6.1.4.1.3582.4.1.11.1 |