414
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

414 total
Object Name
lsi
OBJECT IDENTIFIER
.1.3.6.1.4.1.3582
RFC1213-MIB
Unknown
.1.3.6.1.4.1.3582
storageComponents
OBJECT IDENTIFIER
.1.3.6.1.4.1.3582.4
lsiRAIDServer
OBJECT IDENTIFIER
.1.3.6.1.4.1.3582.4.1
hostNameName of the host system.ro
DisplayString
.1.3.6.1.4.1.3582.4.1.1
hostOSInfoOperating System description where SNMP agent is running.ro
DisplayString
.1.3.6.1.4.1.3582.4.1.2
versionInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.3582.4.1.3
mibVersionThe MIB version no. (xx.yy)ro
DisplayString
.1.3.6.1.4.1.3582.4.1.3.1
agentModuleNameThe agent module namero
DisplayString
.1.3.6.1.4.1.3582.4.1.3.2
agentModuleVersionThe module version in xx.yy format. Where xx is the major version number and yy is the minor version number(without build information).ro
DisplayString
.1.3.6.1.4.1.3582.4.1.3.3
releaseDateModule Release Datero
DisplayString
.1.3.6.1.4.1.3582.4.1.3.4
megaRAID-SAS
OBJECT IDENTIFIER
.1.3.6.1.4.1.3582.4.1.4
adapter
OBJECT IDENTIFIER
.1.3.6.1.4.1.3582.4.1.4.1
adpNumberThe total no of SAS adapters present.ro
Gauge
.1.3.6.1.4.1.3582.4.1.4.1.1
adapterPropertiesTableA List of adapter Entries containing Information/Properties about the adapters.
SEQUENCE OF AdapterPropertiesEntry
.1.3.6.1.4.1.3582.4.1.4.1.2
adapterPropertiesEntryAn Entry in the adapter table.
AdapterPropertiesEntry
.1.3.6.1.4.1.3582.4.1.4.1.2.1
adapterID-APTAdapterID for this Adapter.(Unique)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.1
rebuildRateRebuild rate on this Adapter.rw
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.2
reconstructionRateReconstruction rate on this Adapter.rw
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.3
alarmStateAlarm is enabled or disabled on this adapter. Values: disabled(0),enabled(1)rw
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.4
cacheFlushIntervalCache flush interval in seconds for this adapter.ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.5
clusterStateCluster is enabled or disabled on this adapter. Values: disabled(0),enabled(1)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.6
predFailPollIntervalNumber of seconds between precdictive fail polls on this adapter.rw
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.7
intThrottleCountInterrupt throttle active count on this adapter.rw
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.8
intThrottleTimeUsInterrupt throttle completion hold time on this adapter.rw
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.9
patrolReadRatePatrol Read Rate for this adapter.rw
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.10
bgiRateBackground initialization rate for this adapter.rw
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.11
spinupDelayNumber of seconds to delay among spinup groups for this adapter.rw
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.12
spinupDriveCountMaximum number of drives to spin up at one time for this adapter.rw
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.13
coercionModeDrive capacity coercion mode. 0->None; 1->128MB; 2->1GBro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.14
nvramSizeNVRAM size in KB for this adapter.ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.15
memorySizeMemory size in MB for this adapter.ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.16
flashSizeFlash size in MB for this adapter.ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.17
vdPresentCountVirtual devices present in this adapter.ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.18
vdDegradedCountNumber of virtual devices in this adapter that are criticalro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.19
vdOfflineCountNumber of virtual devices in this adapter that are offlinero
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.20
pdPresentCountPhysical devices present in this adapter.ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.21
pdDiskPresentCountPhysical disk devices present in this adapter.ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.22
pdDiskPredFailureCountNumber of disk devices in this adapter that are criticalro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.23
pdDiskFailedCountNumber of disk devices in this adapter that are failedro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.24
ccRateConsistency Check rate on this Adapter.rw
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.25
compatibilityFlagTo inform compatibilities between Applications and FW. 0->incompatible; 1->compatiblero
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.26
compatibilityInfoCompatibility Information. Format->(Firmware Forward compatibility flag:Firmware Backward compatibility flag:Firmware version flag:Application Forward compatibility flag:Application Backward compatibility flag:Application version flag)ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.1.2.1.27
abortCConErrorAbort CC on detecting error is enabled or disabled on this adapter. Values: No(0),Yes(1),NA(2)rw
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.28
copyBackStateCopyBack is enabled or disabled on this adapter.Values: disabled(0),enabled(1)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.29
revisionIdentifierBoard revision ID for this Adapter.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.1.2.1.30
multipathSupportMultipath is supported or not supported on this adapter.Values: not supported(0),supported(1)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.31
ssdSMARTerEnabledCopyback to SSD on SMART error. Values Enabled(0),Disabled(1)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.32
enableSpinDownUnconfiguredSpin Down Unconfigured Drives(1), Do Not Spin Down Unconfigured Drives(0)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.33
disableSpinDownHotSpareSpin Down Hotspares(0), Do Not Spin Down Hotspares(1)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.34
spinDownTimeSpinDownTime in minutesro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.35
spinupEnclDriveCountMaximum number of drives that can be spin up in an enclosurero
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.36
spinupEnclDelayDelay between drive spin up for drives within an enclosurero
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.37
defaultLdPSPolicypower saving policy.values:controller default power saving policy=0, AUTO=1, MAX=2, Max with no cache=6, NONE=255ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.38
disableLdPSIntervalLD power savings are disabled for yy hours beginning at disableLdPSTime.ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.39
disableLdPSTimeLD power savings shall be disabled at xx minutes from 12:00am.ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.40
supportBreakMirror1=Support break mirror operation,0=Do not Support break mirror operationro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.41
temperatureROCtemperature of RAID On Chip in Celsiusro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.42
temperatureCtrltemperature of controller in Celsiusro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.43
preventPIImport1=Prevent import of SAS PI protected logical disks , 0=Not Prevent import of SAS PI protected logical disksro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.44
enablePI1 = Enable SAS PI for controller , 0 = Disable SAS PI for controllerro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.45
totalSpaceformetadataTotal Space used for MetaDataro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.46
useEmergencySpareThis field give the information about Emergency Spare possible Drive types(Uncongiured Good/Global Hotspare)ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.1.2.1.47
useEmergencySparesforSMARTer1 = Use Emergency spares for SMARTer ,0 = Not Use Emergency spares for SMARTerro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.48
supportShieldState1 =Support PD shield state ,0 = Not Support PD shield statero
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.49
writeCacheCapable1 = SSC support write caching IOs ,0 = SSC not support write caching IOsro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.50
totalCacheSizeThis field give the information about total Size of currently configured SSC,in GBro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.51
maximumCacheSizeThis field give the information about maxmium Size of SSC that can yet be configured,in GBro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.52
ctrlSasAddrThis field gives the controller SAS addressro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.1.2.1.53
domainIdThis field gives the Domain IDro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.1.2.1.54
peerControllerStatusThis field gives the Peer controller Statusro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.1.2.1.55
maximumControllerNodesThis field gives the HA nodes this FW supportsro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.56
incompatibilityDetailsThis field gives the Incompatibility Detailsro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.1.2.1.57
topologyTypeThis field gives the Topology Typero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.1.2.1.58
supportOnlineFWUpdate1 = Online firmware update is supported, 0 = Online firmware update is not supportedro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.2.1.59
adapterInfoTableA List of adapter Entries containing Information/Properties about the adapters on the Controller.
SEQUENCE OF AdapterInfoEntry
.1.3.6.1.4.1.3582.4.1.4.1.3
adapterInfoEntryAn Entry in the adapterInfo table.
AdapterInfoEntry
.1.3.6.1.4.1.3582.4.1.4.1.3.1
adapterID-AITAdapterID for this Adapter.(Unique)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.3.1.1
adapterVendorIDPCI Vendor ID for this Adapter.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.1.3.1.2
devIDPCI Device ID for this Adapter.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.1.3.1.3
subVendorIDPCI Sub-Vendor ID for this adapter.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.1.3.1.4
subDevIDPCI Sub-Device ID for this adapter.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.1.3.1.5
hostInterfaceHost interface information for this adapter. Values: N/A(0),PCIX(1),PCIE(2),iSCSI(3),SAS-3G(4)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.3.1.6
hostInterfacePortCntPort Count on this adapter.ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.3.1.7
hostInterfacePortAddrPort address comma delimitedro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.1.3.1.8
devInterfaceMultiple device interface support values separated by space.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.1.3.1.9
devInterfacePortCntDevice Port Count on this adapter.ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.3.1.10
devInterfacePortAddrDevice Port address comma delimitedro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.1.3.1.11
productNameProduct name e.g. MegaRAID SAS-8E, MegaRAID SAS-4X, etc.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.1.3.1.12
serialNoController serial numberro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.1.3.1.13
firmwareVersionFirmware version Format->(Firmware Package Version:Version:Date:Time)ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.1.3.1.14
driverVersionDriver version Format->(Driver Name:Version)ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.1.3.1.15
expanderFirmwareVersionExpander firmware version - Not Available if expander is not present on the controllerro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.1.3.1.16
lockKeyBindingType of lock key binding. lock key is not bound(0),lock key bound to FW secret key(1), lock key bound to user(2), lock key bound to a TPM(3)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.3.1.17
maxDAPdCountSpinup60Maximum number of drives to spinup within 60 sec for direct attached drivesro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.3.1.18
adapterSupportInfoTableA List of adapter Entries containing Information/Properties about the adapters on the Controller.
SEQUENCE OF AdapterSupportInfoEntry
.1.3.6.1.4.1.3582.4.1.4.1.4
adapterSupportInfoEntryAn Entry in the adapter table.
AdapterSupportInfoEntry
.1.3.6.1.4.1.3582.4.1.4.1.4.1
adapterID-ASITAdapterID for this Adapter.(Unique)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.4.1.1
maxArmsMaximum arms per Virtual Drive supported for this Adapter.ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.4.1.2
maxSpansMaximum spans per Virtual Drive supported for this Adapter.ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.4.1.3
maxArraysMaximum no of arrays supported for this adapter.ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.4.1.4
maxVDsMaximum number of Virtual Drive s supported for this adapter.ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.4.1.5
hardwarePresentSupported Hardware on this adapter. bbu(1),alarm(2),nvram(3),uart(4),TPM(5),expander(6). For multiple hw support a space delimited list will appear.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.1.4.1.6
maxConcurrentCmdsThe maximum parallel commands supported on this adapter.ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.4.1.7
maxSGECountThe maximum Scatter Gather Element count allowed on this adapter.ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.4.1.8
maxRequestSizeThe maximum data transfer size in sectors, on this adapter.ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.4.1.9
maxLdsPerArrayMax Ld's per array in adapterro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.4.1.10
partitionsInDDFMax LD's per Array in configurationro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.4.1.11
allowSSDMixInLDallow SAS/SATA SSD mix within an LD. allow(1), not allow(0)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.4.1.12
allowMixSSDHDDInLDallow SSD/HDD mix within an LD.allow(1), not allow(0)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.4.1.13
adapterOperationsSupportInfoTableA List of adapter Entries containing Information/Properties about the adapters on the Controller.
SEQUENCE OF AdapterOperationsSupportInfoEntry
.1.3.6.1.4.1.3582.4.1.4.1.5
adapterOperationsSupportInfoEntryAn Entry in the adapter table.
AdapterOperationsSupportInfoEntry
.1.3.6.1.4.1.3582.4.1.4.1.5.1
adapterIDAdapterID for this Adapter.(Unique)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.5.1.1
rbldRateSupportedRebuilding rate change support for this Adapter. Values: false(0),true(1)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.5.1.2
ccRateSupportedConsistency Check rate change support for this Adapter. Values: false(0),true(1)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.5.1.3
bgiRateSupportedBackground initialization rate change support for this adapter. Values: false(0),true(1)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.5.1.4
reconRateSupportedReconstruction rate change support for this adapter. Values: false(0),true(1)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.5.1.5
patrolRateSupportedPatrol read rate change support for this adapter. Values: false(0),true(1)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.5.1.6
alarmControlSupportedAlarm control support for this adapter. Values: false(0),true(1)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.5.1.7
clusterSupportedCluster support for this adapter. Values: false(0),true(1)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.5.1.8
bbuSupportedBBU support for this adapter. Values: false(0),true(1)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.5.1.9
spanningAllowedSupportedSpanning support for this adapter. Values: false(0),true(1)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.5.1.10
dedicatedHotSparesSupportedDedicated HotSpares support for this adapter. Values: false(0),true(1)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.5.1.11
revertibleHotSparesSupportedRevertible HotSpares support for this adapter. Values: false(0),true(1)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.5.1.12
foreignConfigImportSupportedSupport foreign config import on this adapter. Values: false(0),true(1)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.5.1.13
selfDiagnosticSupportedController supports self diagnostic. Values: false(0),true(1)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.5.1.14
allowMixedRedundancyOnArraySupportedAllow different Virtual Disk on the same array to have different redundancy levels. Values: false(0),true(1)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.5.1.15
abortCConErrorSupportedAbort CC on detecting error is supported on this adapter. Values: No(0),Yes(1)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.5.1.16
securitySupportedDisplays the security support. if supported (1) , not supported (0)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.5.1.17
supportPIcontrollerDisplays the support PI. 1=LD SAS PI Type 0, 0=LD Not SAS PI Type 0ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.5.1.18
bbuInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.3582.4.1.4.1.6
bbuNumberThe present number of rows in the BBU Table.ro
Gauge
.1.3.6.1.4.1.3582.4.1.4.1.6.1
bbuTableA List of BBU Entries containing Information/Properties about the BBU.
SEQUENCE OF BBUEntry
.1.3.6.1.4.1.3582.4.1.4.1.6.2
bbuEntryAn Entry in the BBU table.
BBUEntry
.1.3.6.1.4.1.3582.4.1.4.1.6.2.1
bbuIDBBUID for this BBU.(Unique)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.1
batteryTypeBBU Type.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.2
nextLearnTimeTime of next scheduled learn cycle (seconds past 1/1/2000)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.3
absStateOfChargePredicted remaining capacity expressed as % of DesignCapacity() (0-100). Value of -1 means not supportedro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.4
fullChargeCapacityPredicted pack capacity when it is fully charged in joulesro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.5
averageEmptyTimeOne-minute rolling average of the predicted remaining battery life. Value of -1 means not supportedro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.6
cycleCountNumber of charge cycles the battery has experienced. Value of -1 means not supportedro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.7
firmwareStatusCondition of battery in following order: packMissing(0/1) voltageLow(0/1) temperatureHigh(0/1) chargeActive(0/1) dischargeActive(0/1) learnCycleRequested(0/1) learnCycleActive(0/1) learnCycleFailed(0/1) learnCycleTimeout(0/1) i2cErrorsDetected(0/1) noSpace(0/1) predictiveFailure(0/1) premiumFeatureReqd(0/1) microcodeUpdateReqd(0/1) Only enabled(1) values will be shownro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.8
voltageAccurate battery terminal voltage in mV, resolution of 1mVro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.9
autoLearnPeriodTime (in seconds) between learn cycles (0 to disable auto learn)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.10
relStateOfChargePredicted remaining capacity expressed as % of FullChargeCapacity() (0-100). Value of -1 means not supportedro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.11
capacityRemainPredicted charge or energy remaining in the battery in joulesro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.12
runTimeToEmptyRelative gain or loss in remaining life in response to change in power policy represent in minute. Value of -1 means not supportedro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.13
avgTimeToFullOne-minute rolling average of predicted remaining time to full charge. Value of -1 means not supportedro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.14
errorMarginExpected margin of error (%) in charge calculation (2-100). Value of -1 means not supportedro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.15
temperatureBattery temperature in degree Centigradero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.16
mfgNameBattery manufacturer's namero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.17
deviceNameBattery namero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.18
serialNumberBattery serialNumberro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.19
chargerStatusBattery charger status. Values: N/A(-1), off(0), complete(1), progress(2)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.20
adpIDThe adapter id where BBU is attachedro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.21
remainingCapAlarmRemaining capacity to alarm. Value of -1 means not supportedro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.22
remainingTimeAlarmRemaining time to alarm. Value of -1 means not supportedro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.23
bbu-currentCurrent(In mA) being supplied (or accepted) through the battery terminalsro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.24
gasGaugeStatusGas gauge statusro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.25
bbuFRUbbu FRUro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.26
batteryReplacementThis property denotes whether the Battery needs to be replaced or not.1 =battery needs to be replaced ,0 =battery needs not to be replacedro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.27
bbuRetentiontimeThe total no. of hours the battery can support the current capacity reserve. Undefined(0),48 hours+(>48),the exact no of hours(<=48)ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.28
bbuStateThis property gives the Information about BBU state. Operational = if BBU is working fine, Non-Operational = if BBU is not working finero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.29
memoryModuleFRUtmm FRUro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.30
bbuFirmwareVersionBattery Firmware Versionro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.31
commonDeviceInfoTableA List of general Physical Disk info
SEQUENCE OF CommonDeviceInfoEntry
.1.3.6.1.4.1.3582.4.1.4.1.7
commonDeviceInfoEntryAn Entry in the CommonDeviceInfo table.
CommonDeviceInfoEntry
.1.3.6.1.4.1.3582.4.1.4.1.7.1
adapterID-CDITUnique adapter IDro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.7.1.1
forceOnlinePhysical drive force Online operation support. Values: notSupported(0), supported(1)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.7.1.2
forceOfflinePhysical drive force Offline operation support. Values: notSupported(0), supported(1)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.7.1.3
forceRebuildPhysical drive force Rebuild operation support. Values: notSupported(0), supported(1)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.7.1.4
supportsSASSAS physical drive support. Values: notSupported(0), supported(1)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.7.1.5
supportsSATASATA physical drive support. Values: notSupported(0), supported(1)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.7.1.6
allowMixInEnclosureMix InEnclosure support. Values: notSupported(0), supported(1)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.7.1.7
allowMixInVDMixInVIRTUALDRIVE support. Values: notSupported(0), supported(1)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.7.1.8
allowSataInClusterSataInCluster support. Values: notSupported(0), supported(1)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.7.1.9
setPowerStateForCfgFW requires application to set power state before configuration changes. Required(1), Not Required(0)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.7.1.10
commonVirtualDeviceInfoTableA List of general Virtual Drive info
SEQUENCE OF CommonVirtualDeviceInfoEntry
.1.3.6.1.4.1.3582.4.1.4.1.8
commonVirtualDeviceInfoEntryAn Entry in the CommonVirtualDeviceInfo table.
CommonVirtualDeviceInfoEntry
.1.3.6.1.4.1.3582.4.1.4.1.8.1
adapterID-CVDITUnique adapter IDro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.8.1.1
supportedReadPolicyRead policy support. Values: false(0),true(1)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.8.1.2
supportedWritePolicyWrite policy support. Values: false(0),true(1)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.8.1.3
supportedIOPolicyIO policy support. Values: false(0),true(1)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.8.1.4
supportedAccessPolicyAccess policy support. Values: false(0),true(1)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.8.1.5
supportedMinSizeMinimum stripe size supported. 0(512B),1(1K),2(2K),3(4K),4(8K),5(16K),6(32),7(64K),8(128K) ... 11(1MB) etcro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.8.1.6
supportedMaxSizeMaximum stripe size supported. 0(512B),1(1K),2(2K),3(4K),4(8K),5(16K),6(32),7(64K),8(128K) ... 11(1MB) etcro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.8.1.7
ldbbm1=LD bad block management is enabled, 0=LD bad block management is not enabledro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.8.1.8
adapterStatusSupportInfoTableA List of adapter Entries containing Information/Properties about the adapters on the Controller.
SEQUENCE OF AdapterStatusSupportInfoEntry
.1.3.6.1.4.1.3582.4.1.4.1.9
adapterStatusSupportInfoEntryAn Entry in the adapter table.
AdapterStatusSupportInfoEntry
.1.3.6.1.4.1.3582.4.1.4.1.9.1
adapterID-ASSITAdapterID for this Adapter.(Unique)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.9.1.1
lockKeyAssignedLock key Assigned support for this Adapter. Values: false(0),true(1)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.9.1.2
lockKeyFailedlock Key Failed support for this Adapter. Values: false(0),true(1)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.9.1.3
lockKeyNotBackeduplock Key Not Backedup support for this Adapter. Values: false(0),true(1)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.9.1.4
biosNotDetectedbios Not Detected support for this Adapter. Values: false(0),true(1)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.9.1.5
cacheIsPinned1=controller cache is pinned for missing or offline LDsro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.9.1.6
adapterLdOperationSupportInfoTableA List of adapter Entries containing Information/Properties about the adapters on the Controller.
SEQUENCE OF AdapterLdOperationSupportInfoEntry
.1.3.6.1.4.1.3582.4.1.4.1.10
adapterLdOperationSupportInfoEntryAn Entry in the adapter table.
AdapterLdOperationSupportInfoEntry
.1.3.6.1.4.1.3582.4.1.4.1.10.1
adapterID-ALSITAdapterID for this Adapter.(Unique)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.10.1.1
allowCtrlEncryptionif it is set (1) supports controller encryptionro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.1.10.1.2
device
OBJECT IDENTIFIER
.1.3.6.1.4.1.3582.4.1.4.2
physicalDriveInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.3582.4.1.4.2.1
pdNumberThe present number of rows in the physical drive table.ro
Gauge
.1.3.6.1.4.1.3582.4.1.4.2.1.1
physicalDriveTableA List of physical drive Entries containing Information/Properties about the drives
SEQUENCE OF PhysicalDriveEntry
.1.3.6.1.4.1.3582.4.1.4.2.1.2
physicalDriveEntryAn Entry in the Device Table.
PhysicalDriveEntry
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1
pdIndexThe unique IDro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.1
physDevIDThe Device IDro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.2
oemSupportedIs the drive supported by the OEM (OEM-specific checks). Values: notSupported(1), supported(0)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.3
scsiDevTypeType of this Device. Values: disk(0),tape(1),printer(2),processor(3),cdrom(5),scanner(6),optical(7),enclosure(13),dvd(10),unknown(31)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.4
connectedAdapterPortAdapter port(s) to which the device is connected.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.5
deviceSpeedMaximum supported speed. Values: speed-unknown(0),speed-1p5G(1),speed-3G(2),speed-6G(3)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.6
mediaErrCountError count of the devicero
INTEGER
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.7
otherErrCountOther error count of the devicero
INTEGER
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.8
predFailCountPredictive fail count of the devicero
INTEGER
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.9
pdStateFirmware's interpretation of drive state. Values: unconfigured-good(0),unconfigured-bad(1),hot-spare(2),offline(16),failed(17),rebuild(20),online(24),copyback(32),system(64),UNCONFIGURED-SHIELDED(128),HOTSPARE-SHIELDED(130),CONFIGURED-SHIELDED(144)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.10
disabledForRemovalIf true, drive is ready for removal. Values: false(0),true(1)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.11
linkSpeedNegotiated link speed. Values: speed-unknown(0),speed-1p5G(1),speed-3G(2),speed-6G(3)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.12
pdSupportFlags1st Byte:forcedPDGUID(0/1),2nd Byte:inVD(0/1),3rd Byte:isGlobalSpare(0/1),4th Byte:isSpare(0/1),5th Byte:isForeign(0/1),6th Byte:intf(0-Unknown, 1-parallel SCSI, 2-SAS, 3-SATA, 4-FC).A comma delimited list will appear.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.13
sasAddrDevice SAS addresses. Comma separeted for multiple addressro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.14
rawSizeSize(MB) before COD and coercionro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.15
nonCoercedSizeSize(MB) after COD is reserved but before coercionro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.16
coercedSizeSize(MB) after COD is reserved and after coercionro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.17
enclDeviceIdEnclosure's device Id (in decimal); if device is not within enclosure value is -1ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.18
enclIndexFirmware internal enclosure indexro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.19
slotNumberSlot number of this drive, if the Physical Disk is part of an enclosure then -1ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.20
operationProgressOperation progress in %. e.g. Rebuild progress is 10%ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.21
adpID-PDTController id where this Physical Drive is attachedro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.22
operationSupportMakeOnline,MakeOffline,MakeFailed,MakeBad,MakeUncofigured, MakeSpare,RemoveSpare,replaceMissing,markMissing,startRebuild, stopRebuild,locate,pdclear,foreignImportNotAllowed,ForeignImportAllowed, startCopyBack,stopCopyBack,fwDownloadNotAllowed,fwDownloadAllowed,makeSystemro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.23
pdVendorIDVendor IDro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.24
pdProductIDProduct IDro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.25
pdFwversionPD firmware versionro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.26
diskTypeType of the disk : 0-Unknown, 1-parallel SCSI, 2-SAS, 3-SATA, 4-FCro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.27
partnerDevIdIf drive is in an enclosure with dual paths,This is Partner Device ID. In all other cases INVALID(-1)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.28
mediatypeMedia Type HDD(0),SSD(1),Solid state flash module(2)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.29
powerStatePower condition of the device. Values are device is active(0),device is stopped(1),device is transitioning between power states(255)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.30
secured1=drive is secured, 0=not securedro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.31
locked1=drive is locked, 0=unlockedro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.32
foreign1=drive is secured by a foreign lock key, 0=drive is not secured by a foreign lock keyro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.33
oemCertifiedIs the drive certified by the OEM (OEM-specific checks). Values: notCertified(1), Certified(0)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.34
foreignImportNotAllowed1=Drive is not allowed foreignImport operation, 0=Drive is allowed foreignImport operationro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.35
pdTemperaturePhysical Drive temperature in Celsiusro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.36
pdSerialNumberPhysical Drives serial numberro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.37
piEligibleProtection Information eligibility.1=drive can be used for PD Enabled LD , 0=drive can't be used for PD Enabled LDro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.38
piTypeSAS Protection Information Type .No SAS protection type used(0) ,SAS PI Type 1(1) ,SAS PI Type 2(2) ,SAS PI Type 3(3) ,Reserved SAS PI Type 4(4) ,Reserved SAS PI Type 5(5) ,Reserved SAS PI Type 6(6) ,Reserved SAS PI Type 7(7).ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.39
piFormattedformatted for PI information. 1=drive is formatted for PI information, 0=no PI data.ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.40
userDataBlockSizeNumber of bytes of user data in LBAro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.41
commissionedSpareYes = this PD is a commissioned spare, No = this PD is not a commissioned spare.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.42
emergencySpareEligible = this PD is a emergency spare, Ineligible = this PD is not a emergency spare.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.43
shieldCounterHow many times the shield diagnostics was run before it was marked failedro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.44
shieldDiagCompletionTimeLast successful Diagnostics completion time. 0 is N/Aro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.45
ineligibleForSSCDWhether PD cannot be used for an SSCD. PD can not be used for an SSCD(1), PD can be used for an SSCD(0)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.46
ineligibleForLdWhether PD cannot be used for a regular LD. PD can not be used for a regular LD(1), PD can be used for a regular LD(0)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.47
virtualDevice
OBJECT IDENTIFIER
.1.3.6.1.4.1.3582.4.1.4.3
vdInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.3582.4.1.4.3.1
vdNumbersThe present number of rows in the virtualDrive table.ro
Gauge
.1.3.6.1.4.1.3582.4.1.4.3.1.1
virtualDriveTableA List of Virtual Drives Entries containing Information/Properties about the virtualDrive.
SEQUENCE OF VirtualDriveEntry
.1.3.6.1.4.1.3582.4.1.4.3.1.2
virtualDriveEntryAn Entry in the virtualDrive Table.
VirtualDriveEntry
.1.3.6.1.4.1.3582.4.1.4.3.1.2.1
virtualDevIDThe unique Virtual Drives IDro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.3.1.2.1.1
sizeTotal size in MB of the drivero
INTEGER
.1.3.6.1.4.1.3582.4.1.4.3.1.2.1.2
clusterOwnerDeviceIdVD owner's device Idro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.3.1.2.1.3
targetIdVirtual Drive target id (i.e. 0 to 63)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.3.1.2.1.4
stateThe Device state: Values: offline(0),partially-degraded(1),degraded(2),optimal(3)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.3.1.2.1.5
nameVirtual Drive namero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.3.1.2.1.6
defaultCachePolicyDefault cache policy settings. Values: WriteBack, WriteThrough, ReadAdaptive, ReadAhead, ReadAheadNone, Cached, Direct, Write Cache OK if Bad BBU, No Write Cache if Bad BBU.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.3.1.2.1.7
accessPolicyAccess policy settings. Values: access-rw(0), access-read-only(2), access-blocked(3)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.3.1.2.1.8
diskCachePolicyPhysical disk cache policy. Values: unchanged(0),enable(1),disable(2)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.3.1.2.1.9
bgiStateDisable/Enable Back Groung Initialization on this Virtual Drive. Values: disable(1),enable(0)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.3.1.2.1.10
prlPrimay raid level. Values: 0(RAID-0), 1(RAID-1), 3(RAID-3), 4(RAID-4), 5(RAID-5), 6(RAID-6),15(Single Disk or JBOD), 17(RAID-1E), 21(RAID-5E), 31(Concatenation),37(RAID-5EEE)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.3.1.2.1.11
rLQRaid level qualifierro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.3.1.2.1.12
sRLSecondary raid level. Values: 0(Stripped), 1(Mirrored), 2(Concatenated), 3(Spanned)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.3.1.2.1.13
stripeSizeStripe Size. 0(512B),1(1K),2(2K),3(4K),4(8K),5(16K),6(32),7(64K),8(128K) ... 11(1MB) etcro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.3.1.2.1.14
numDrivesNumber of drivers per spanro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.3.1.2.1.15
spanDepthNumber of spans. If only one array then it is considered as 1 spanro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.3.1.2.1.16
initState0=no init, 1=quick init, 2=full initro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.3.1.2.1.17
vdOperationProgressProgress % for an operation / No operation in progressro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.3.1.2.1.18
currentCachePolicyCache policy settings. Values:WriteBack, WriteThrough, ReadAdaptive, ReadAhead, ReadAheadNone, Cached, Direct, Write Cache OK if Bad BBU, No Write Cache if Bad BBU.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.3.1.2.1.19
adapterID-VDTAdapter IDro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.3.1.2.1.20
encryptionTypelogical drive encryption type. Values No Encryption(0), FDE drive encryption(1), Controller-based encryption(2)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.3.1.2.1.21
vdOperationSupportstartFGI,stopFGI,startCC,stopCC,startRecon,deleteLDro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.3.1.2.1.22
badBlocksExist0 = LD bad block table is empty, 1 = LD bad block table is not emptyro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.3.1.2.1.23
defaultPSPolicyPower Savings policy set for this LD.Values:controller default power saving policy=0, AUTO=1, MAX=2, MAX with no cache=6, NONE=255ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.3.1.2.1.24
currentPSPolicyPower Savings policy set for this LD.Values:controller default power saving policy=0, AUTO=1, MAX=2, MAX with no cache=6, NONE=255ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.3.1.2.1.25
breakMirrorBreak Mirror Policy set for this LD.Values:1=break mirror is allowed, 0=break mirror not is allowedro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.3.1.2.1.26
joinMirrorJoin Mirror policy set for this LD.Values:1=join mirror is allowed, 0=join mirror not is allowedro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.3.1.2.1.27
mirrorPdInfoMirror Info Property give the Information about mirror of PD and PD state respectively.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.3.1.2.1.28
vdPiTypeInformation about logical drive protection type . No SAS protection type used(0) ,SAS PI Type 1(1) ,SAS PI Type 2(2) ,SAS PI Type 3(3) ,Reserved SAS PI Type 4(4) ,Reserved SAS PI Type 5(5) ,Reserved SAS PI Type 6(6) ,Reserved SAS PI Type 7(7) ,SAS PI Type 8(8).ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.3.1.2.1.29
mirrorDataSizeTotal Space used for mirrorData or Parity informationro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.3.1.2.1.30
cacheCadeType0= Non-CacheCade VD, 1= CacheCade Type is Read & Write, 2= CacheCade Type is Read only, 3= R1-ECro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.3.1.2.1.31
currentWritePolicyCurrent write policy settings. Values: WriteBack, WriteThrough, AlwaysWriteBackro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.3.1.2.1.32
defaultWritePolicyDefault write policy settings. Values: WriteBack, WriteThrough, AlwaysWriteBackro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.3.1.2.1.33
associatedVDThis property gives the Information about VD is Cached or VD is not cached.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.3.1.2.1.34
hostAccessPolicyThis property gives the Host Access Policyro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.3.1.2.1.35
guidThis property gives the LD GUID.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.3.1.2.1.36
vdSpanInfoTableA List of span Entries containing Information/Properties vd span.
SEQUENCE OF VDSpanInfoEntry
.1.3.6.1.4.1.3582.4.1.4.3.1.3
vdSpanInfoEntryAn Entry in the vdSpan Table.
VDSpanInfoEntry
.1.3.6.1.4.1.3582.4.1.4.3.1.3.1
spanIDThe unique Span IDro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.3.1.3.1.1
vdID-VSITThe Virtual Device IDro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.3.1.3.1.2
startBlockSpan physical disk starting blockro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.3.1.3.1.3
numBlocksSpan physical disk block countro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.3.1.3.1.4
vdSpanArrayRefArray reference (index)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.3.1.3.1.5
adapterID-VSITAdapter IDro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.3.1.3.1.6
arrayInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.3582.4.1.4.3.4
arrayNumberThe present number of rows in the array table.ro
Gauge
.1.3.6.1.4.1.3582.4.1.4.3.4.1
arrayTableA List of array Entries containing Information/Properties about the arrays.
SEQUENCE OF ArrayEntry
.1.3.6.1.4.1.3582.4.1.4.3.4.2
arrayEntryAn Entry in the array Table.
ArrayEntry
.1.3.6.1.4.1.3582.4.1.4.3.4.2.1
arrayIDThe unique array IDro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.3.4.2.1.1
arraySizeSize in MBro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.3.4.2.1.2
arrayNumDrivesNumber of drives for this arrayro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.3.4.2.1.3
arrayRefTag for the arrayro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.3.4.2.1.4
pdListSpace separated Physical Drive identification. e.g. {devID devID devID} etcro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.3.4.2.1.5
adapterID-ATAdapter ID.ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.3.4.2.1.6
spareInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.3582.4.1.4.3.5
spareDevNumberThe present number of rows in the sparepool table.ro
Gauge
.1.3.6.1.4.1.3582.4.1.4.3.5.1
spareTableA List of sparepool Entries containing Information/Properties about the spare drive
SEQUENCE OF SpareEntry
.1.3.6.1.4.1.3582.4.1.4.3.5.2
spareEntryAn Entry in the sparepool Table.
SpareEntry
.1.3.6.1.4.1.3582.4.1.4.3.5.2.1
spareIDThe unique Device IDro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.3.5.2.1.1
deviceIdentificationThe unique Device IDro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.3.5.2.1.2
spareTypeSpare type. isDedicated(0/1)isRevertible(0/1)isEnclAffinity(0/1). 1 implies particular feature is enable and 0 represent feature is disable.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.3.5.2.1.3
arrayCountThe number of arrays to which the Physical Drive can be dedicatedro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.3.5.2.1.4
arrayIDsComma separated array ids. e.g. 2,4,5 etcro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.4.3.5.2.1.5
adapterID-STAdapter ID.ro
INTEGER
.1.3.6.1.4.1.3582.4.1.4.3.5.2.1.6
enclosureInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.3582.4.1.5
enclosureNumberThe present number of rows in the enclosure table.ro
Gauge
.1.3.6.1.4.1.3582.4.1.5.1
enclosureTableA List of Enclosure Entries containing Information/Properties about the enclosures in the system.
SEQUENCE OF EnclosureEntry
.1.3.6.1.4.1.3582.4.1.5.2
enclosureEntryAn Entry in the enclosure table.
EnclosureEntry
.1.3.6.1.4.1.3582.4.1.5.2.1
enclosureIDEnclosureID for this enclosure.(Unique)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.5.2.1.1
deviceIdEnclosure device Id.ro
INTEGER
.1.3.6.1.4.1.3582.4.1.5.2.1.2
enclosureIndexFirmware internal enclosure indexro
INTEGER
.1.3.6.1.4.1.3582.4.1.5.2.1.3
slotCountNumber of slotsro
INTEGER
.1.3.6.1.4.1.3582.4.1.5.2.1.4
psCountNumber of power suppliesro
INTEGER
.1.3.6.1.4.1.3582.4.1.5.2.1.5
fanCountNumber of fansro
INTEGER
.1.3.6.1.4.1.3582.4.1.5.2.1.6
tempSensorCountNumber of temperature sensorsro
INTEGER
.1.3.6.1.4.1.3582.4.1.5.2.1.7
alarmCountNumber of alarmsro
INTEGER
.1.3.6.1.4.1.3582.4.1.5.2.1.8
simCountNumber of SIM modulesro
INTEGER
.1.3.6.1.4.1.3582.4.1.5.2.1.9
isFaultEnclosure has entered a FAULT state or not. Values: false(0),true(1)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.5.2.1.10
pdCountNumber of physical drives presentro
INTEGER
.1.3.6.1.4.1.3582.4.1.5.2.1.11
pdIdsPhysical drive deviceIds space separated.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.5.2.1.12
adapterID-ETAdapter ID.ro
INTEGER
.1.3.6.1.4.1.3582.4.1.5.2.1.13
pdCountSpinup60Number of drives that can spun up in 60 sec.ro
INTEGER
.1.3.6.1.4.1.3582.4.1.5.2.1.14
enclosureTypeInformation about type of enclosure : 0= UNKNOWN ,1= SAFTE ,2=SES ,3= SGPIO.ro
INTEGER
.1.3.6.1.4.1.3582.4.1.5.2.1.15
enclFirmwareVersionInformation about enclosure FW Versionro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.5.2.1.16
enclSerialNumberEnclosure Serial Numberro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.5.2.1.17
vendorIDEnclosure Vendor IDro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.5.2.1.18
productIDEnclosure Product IDro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.5.2.1.19
eSMSerialNumberIBM Enclosure ESM Serial Numberro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.5.2.1.20
eSMFRUInformation about IBM Enclosure ESM FRUro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.5.2.1.21
enclosureZoningModeEnclosure IBM Zoning Modero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.5.2.1.22
eSMFRUPartInfoInformation about IBM Enclosure ESM FRU Partro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.5.2.1.23
enclosureFanTableA List of fan Entries containing Information/Properties about the enclosureFan.
SEQUENCE OF EnclosureFanEntry
.1.3.6.1.4.1.3582.4.1.5.3
enclosureFanEntryAn Entry in the enclosureFan table.
EnclosureFanEntry
.1.3.6.1.4.1.3582.4.1.5.3.1
fanIDID for this EnclosureFan.(Unique)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.5.3.1.1
enclosureIdEnclosure ID where the fan is attachedro
INTEGER
.1.3.6.1.4.1.3582.4.1.5.3.1.2
fanStatusstatus of the fanro
Enumeration
.1.3.6.1.4.1.3582.4.1.5.3.1.3
enclosureSlotTableA List of slot Entries containing Information/Properties about the enclosure slots.
SEQUENCE OF EnclosureSlotEntry
.1.3.6.1.4.1.3582.4.1.5.4
enclosureSlotEntryAn Entry in the enclosureSlot table.
EnclosureSlotEntry
.1.3.6.1.4.1.3582.4.1.5.4.1
slotIDID for this slot.(Unique)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.5.4.1.1
enclosureId-ESTenclosure IDro
INTEGER
.1.3.6.1.4.1.3582.4.1.5.4.1.2
slotStatusstatus of the devicero
Enumeration
.1.3.6.1.4.1.3582.4.1.5.4.1.3
enclosurePowerSupplyTableA List of powerSupply Entries containing Information/Properties about the enclosure powerSupply
SEQUENCE OF EnclosurePowerSupplyEntry
.1.3.6.1.4.1.3582.4.1.5.5
enclosurePowerSupplyEntryAn Entry in the powerSupply table.
EnclosurePowerSupplyEntry
.1.3.6.1.4.1.3582.4.1.5.5.1
powerSupplyIDID for this powerSupply.(Unique)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.5.5.1.1
enclosureId-EPSTEnclosure id for the powerSupplyro
INTEGER
.1.3.6.1.4.1.3582.4.1.5.5.1.2
powerSupplyStatusStatus of the power Supplyro
Enumeration
.1.3.6.1.4.1.3582.4.1.5.5.1.3
enclosureTempSensorTableA List of TempSensor Entries containing Information/Properties about the enclosure TempSensor
SEQUENCE OF EnclosureTempSensorEntry
.1.3.6.1.4.1.3582.4.1.5.6
enclosureTempSensorEntryAn Entry in the adapter table.
EnclosureTempSensorEntry
.1.3.6.1.4.1.3582.4.1.5.6.1
tempSensorIDID for this TempSensor.(Unique)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.5.6.1.1
enclosureId-ETSTEnclosure id for this TempSensorro
INTEGER
.1.3.6.1.4.1.3582.4.1.5.6.1.2
tempSensorStatusStatus of the Temparature Sensorro
Enumeration
.1.3.6.1.4.1.3582.4.1.5.6.1.3
enclosureTemperatureCurrent temperature in degree Centigradero
INTEGER
.1.3.6.1.4.1.3582.4.1.5.6.1.4
enclosureAlarmTableA List of Alarm Entries containing Information/Properties about enclosure Alarms
SEQUENCE OF EnclosureAlarmEntry
.1.3.6.1.4.1.3582.4.1.5.7
enclosureAlarmEntryAn Entry in the enclosureAlarm table.
EnclosureAlarmEntry
.1.3.6.1.4.1.3582.4.1.5.7.1
alarmIDID for this Alarm.(Unique)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.5.7.1.1
enclosureId-EATEnclosure id where the Alarm is attachedro
INTEGER
.1.3.6.1.4.1.3582.4.1.5.7.1.2
alarmStatusStatus of the alarmro
Enumeration
.1.3.6.1.4.1.3582.4.1.5.7.1.3
enclosureSIMTableA List of SIM Entries containing Information/Properties about enclosure SIMs
SEQUENCE OF EnclosureSIMEntry
.1.3.6.1.4.1.3582.4.1.5.8
enclosureSIMEntryAn Entry in the enclosureSIM table.
EnclosureSIMEntry
.1.3.6.1.4.1.3582.4.1.5.8.1
simIDID for this SIM.(Unique)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.5.8.1.1
enclosureId-ESITInclosure ID where the SIM is attachedro
INTEGER
.1.3.6.1.4.1.3582.4.1.5.8.1.2
simStatusStatus of the SIMro
Enumeration
.1.3.6.1.4.1.3582.4.1.5.8.1.3
adapterTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.3582.4.1.6
atAdpNumberAdapter ID for which Trap is generated.ro
INTEGER
.1.3.6.1.4.1.3582.4.1.6.1001
atAlarmStateAlarm disabled/enabled. Values: disabled(0),enabled(1)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.6.1002
atRateBGI/Check Consistency/Rebuild/Patrol Read/Reconstruction Ratero
INTEGER
.1.3.6.1.4.1.3582.4.1.6.1003
atFlashImageNameFlash Image Namero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.6.1004
atIDIDro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.6.1005
clustCtrlpropResetResetting controller propertyro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.6.1006
vdTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.3582.4.1.7
vdNumbervd Target ID for which Trap is generated.ro
INTEGER
.1.3.6.1.4.1.3582.4.1.7.1101
vdSeqvd Sequence no for which Trap is generated.ro
INTEGER
.1.3.6.1.4.1.3582.4.1.7.1102
vdProgprogress %ro
INTEGER
.1.3.6.1.4.1.3582.4.1.7.1103
vdCachePolicyChangeReasonVD cache policy.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.7.1104
vdNewStateVirtual Drive state. Values are: offline(0),partially-degraded(1),degraded(2),optimal(3)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.7.1105
vdOldStateVirtual Drive state. Values are: offline(0),partially-degraded(1),degraded(2),optimal(3)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.7.1106
isRemoteHA cluster locale: 0=local, 1=remote (at peer)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.7.1107
pdTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.3582.4.1.8
pdIDDevice ID for which Trap is generated.ro
INTEGER
.1.3.6.1.4.1.3582.4.1.8.1201
pdEncIndexEnclosure index(0 means not within an enclosure) for which Trap is generated.ro
INTEGER
.1.3.6.1.4.1.3582.4.1.8.1202
pdSlotNoSlot no for the enclosurero
INTEGER
.1.3.6.1.4.1.3582.4.1.8.1203
pdNewStatePhysical Drive state. Values are: unconfigured-good(0),unconfigured-bad(1),hot-spare(2),offline(16),failed(17),rebuild(20),online(24),copyback(32),system(64)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.8.1204
pdOldStatePhysical Drive state. Values are: unconfigured-good(0),unconfigured-bad(1),hot-spare(2),offline(16),failed(17),rebuild(20),online(24),copyback(32),system(64)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.8.1205
pdEnclDeviceIdEnclosure Device ID for which Trap is generated.ro
INTEGER
.1.3.6.1.4.1.3582.4.1.8.1206
pdSASAddDevice SAS addresses. Comma separeted for multiple address.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.8.1207
pdPathPD path.ro
INTEGER
.1.3.6.1.4.1.3582.4.1.8.1208
pdFRUPD FRU for which trap is generated.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.3582.4.1.8.1209
pdNewPowerStateNew Power Status Of the Device.Values are device is active(0),device is stopped(1),device is transitioning between power states(255)ro
INTEGER
.1.3.6.1.4.1.3582.4.1.8.1210
enclTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.3582.4.1.9
atPortProt no.ro
INTEGER
.1.3.6.1.4.1.3582.4.1.9.1301
onPHYPHY noro
INTEGER
.1.3.6.1.4.1.3582.4.1.9.1302
pciTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.3582.4.1.10
pciVendorIdPCI VendorIDro
INTEGER
.1.3.6.1.4.1.3582.4.1.10.1501
pciDeviceIdPCI Device IDro
INTEGER
.1.3.6.1.4.1.3582.4.1.10.1502
pciSubVendorIdPCI SubVendorIDro
INTEGER
.1.3.6.1.4.1.3582.4.1.10.1503
pciSubDeviceIdPCI SubDeviceIDro
INTEGER
.1.3.6.1.4.1.3582.4.1.10.1504
copyrightInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.3582.4.1.11