LJ3700-MIB
The LJ3700-MIB module enables SNMP-based monitoring of HP LaserJet 3700 series printers, exposing standard counters for page counts, toner levels, and paper tray status alongside device health metrics such as error states and consumable life cycles.
Imported Objects
Objects
713 total| Object Name |
|---|
hp MODULE-IDENTITY .1.3.6.1.4.1.11 |
netPMLmgmt OBJECT IDENTIFIER .1.3.6.1.4.1.11.2.3.9.4.2 |
device OBJECT IDENTIFIER .1.3.6.1.4.1.11.2.3.9.4.2.1 |
device_system OBJECT IDENTIFIER .1.3.6.1.4.1.11.2.3.9.4.2.1.1 |
settings_system OBJECT IDENTIFIER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.1 |
energy_starrw INTEGER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.1.1 |
sleep_moderw Enumeration .1.3.6.1.4.1.11.2.3.9.4.2.1.1.1.2 |
mono_color_switching_moderw Enumeration .1.3.6.1.4.1.11.2.3.9.4.2.1.1.1.31 |
device_configure OBJECT IDENTIFIER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.1.32 |
device_configure_printer_parametersrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11.2.3.9.4.2.1.1.1.32.12 |
status_system OBJECT IDENTIFIER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2 |
on_off_linerw Enumeration .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.5 |
_pysmi_continuerw Enumeration .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.6 |
auto_continuerw Enumeration .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.7 |
install_daterw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.8 |
perm_store_init_occurredro OCTET STRING .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.10 |
timestamprw DisplayString .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.13 |
service_idrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.19 |
display OBJECT IDENTIFIER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.20 |
display_status OBJECT IDENTIFIER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.20.1 |
show_addressrw Enumeration .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.20.1.3 |
display_physical_appearancerw Enumeration .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.20.1.4 |
job_input_auto_continue_timeoutrw INTEGER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.35 |
job_input_auto_continue_moderw OCTET STRING .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.36 |
background_message OBJECT IDENTIFIER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.37 |
background_message1 OBJECT IDENTIFIER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.37.1 |
background_status_msg_line1_part1rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.37.1.1 |
background_message2 OBJECT IDENTIFIER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.37.2 |
background_status_msg_line2_part1rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.37.2.1 |
error_log_clearrw Enumeration .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.38 |
job_output_auto_continue_timeoutrw INTEGER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.40 |
collated_originals_supportro OCTET STRING .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.42 |
localization_languages_supportedro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.52 |
localization_countries_supportedro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.53 |
host_application_available_memoryro INTEGER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.59 |
control_panel_button_pressrw Enumeration .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.60 |
control_panel_display_contents_change_counterro INTEGER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.63 |
control_panel_display_contents_crcro INTEGER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.64 |
control_panel_display OBJECT IDENTIFIER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.65 |
control_panel_display_graphical_contentsro OCTET STRING .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.65.1 |
control_panel_key_pressrw INTEGER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.66 |
page_frame_memory_availablero INTEGER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.72 |
id OBJECT IDENTIFIER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.3 |
model_numberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.1 |
model_namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.2 |
serial_numberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.3 |
fw_rom_datecodero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.5 |
fw_rom_revisionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.6 |
device_namerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.10 |
device_locationrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.11 |
asset_numberrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.12 |
interface OBJECT IDENTIFIER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4 |
simm OBJECT IDENTIFIER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1 |
simm1 OBJECT IDENTIFIER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.1 |
simm1_typero Enumeration .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.1.4 |
simm1_capacityro INTEGER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.1.5 |
simm1_bank OBJECT IDENTIFIER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.1.6 |
simm1_bank1 OBJECT IDENTIFIER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.1.6.1 |
simm1_bank1_typero Enumeration .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.1.6.1.1 |
simm1_bank1_capacityro INTEGER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.1.6.1.2 |
simm1_bank2 OBJECT IDENTIFIER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.1.6.2 |
simm1_bank2_typero Enumeration .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.1.6.2.1 |
simm1_bank2_capacityro INTEGER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.1.6.2.2 |
simm2 OBJECT IDENTIFIER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.2 |
simm2_typero Enumeration .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.2.4 |
simm2_capacityro INTEGER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.2.5 |
simm2_bank OBJECT IDENTIFIER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.2.6 |
simm2_bank1 OBJECT IDENTIFIER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.2.6.1 |
simm2_bank1_typero Enumeration .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.2.6.1.1 |
simm2_bank1_capacityro INTEGER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.2.6.1.2 |
simm2_bank2 OBJECT IDENTIFIER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.2.6.2 |
simm2_bank2_typero Enumeration .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.2.6.2.1 |
simm2_bank2_capacityro INTEGER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.2.6.2.2 |
simm3 OBJECT IDENTIFIER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.3 |
simm3_typero Enumeration .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.3.4 |
simm3_capacityro INTEGER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.3.5 |
simm3_bank OBJECT IDENTIFIER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.3.6 |
simm3_bank1 OBJECT IDENTIFIER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.3.6.1 |
simm3_bank1_typero Enumeration .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.3.6.1.1 |
simm3_bank1_capacityro INTEGER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.3.6.1.2 |
simm3_bank2 OBJECT IDENTIFIER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.3.6.2 |
simm3_bank2_typero Enumeration .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.3.6.2.1 |
simm3_bank2_capacityro INTEGER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.3.6.2.2 |
simm4 OBJECT IDENTIFIER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.4 |
simm4_typero Enumeration .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.4.4 |
simm4_capacityro INTEGER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.4.5 |
simm4_bank OBJECT IDENTIFIER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.4.6 |
simm4_bank1 OBJECT IDENTIFIER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.4.6.1 |
simm4_bank1_typero Enumeration .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.4.6.1.1 |
simm4_bank1_capacityro INTEGER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.4.6.1.2 |
simm4_bank2 OBJECT IDENTIFIER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.4.6.2 |
simm4_bank2_typero Enumeration .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.4.6.2.1 |
simm4_bank2_capacityro INTEGER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.4.6.2.2 |
mio OBJECT IDENTIFIER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3 |
mio1 OBJECT IDENTIFIER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3.1 |
mio1_model_namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3.1.2 |
mio1_manufacturing_inforo DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3.1.3 |
mio1_typero Enumeration .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3.1.4 |
mio2 OBJECT IDENTIFIER .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3.2 |
mio2_model_namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3.2.2 |
LJ3700-MIB Technical Reference Overview
The LJ3700-MIB SNMP MIB module published by HP defines 713 managed OID objects, including 503 scalar/column metrics, 2 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.11. Key tabular structures include channelTable, deviceChannelTable.
Key OID Definitions in LJ3700-MIB
.1.3.6.1.4.1.11Objects used in the HP LaserJet 3700 printer.
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.6A device can support a class of errors called continuable errors. When a continuable error is encountered, the device requires a continue event to occur before the device will continue operation. One continue event is setting the CONTINUE object to eInitiateAction. Devices can support other continue events, like auto-continue. A continue event causes the continuable error to be acknowledged, thus allowing the device to continue. Each device needs to list the continuable errors. If the device doesn't currently have an unacknowledged continuable error, the response will contain <genErr>. Additional information: See the CLEARABLE-WARNING and AUTO-CONTINUE objects for the errors that this object will clear.
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.12User defined asset number. The POS should indicate the maximum supported string length. If the user entered string is too long, the device will store as much as possible and will return the <OKNearestLegal ValueSubstituted>.Additional information: The maximum supported string length is 8 characters. If the user entered string is too long, the device will store the first 8 characters and will return the <noError> status.
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.7Indicates if the device will automatically continue after encountering a continuable error. If AUTO-CONTINUE is set to eOn, the device will automatically generate continue event to acknowledge continuable errors. If AUTO-CONTINUE is set to eOff, then some other continue event will have to acknowledge the continuable error. Additional information: If this is set to eOn the device displays an error message and goes offline for ten seconds. After ten seconds the printer automatically returns to the online state. If this is set to eOff then the device displays an error message and goes offline. It remains offline until the operator presses the GO key or until the CONTINUE object is set. If the printer is not idle, the new value may not take effect until a job boundary is reached. If a get is done on this object before the job boundary is reached, the value last set will be returned.
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.37.1.1The string displayed on the device's front panel in place of the printer's built-in background status string. An example built-in background status string is '00 READY'. Additional information: The display size for the LaserJet 8150 printers is 2 X 16. The value of this object and the current value of BACKGROUND-STATUS-MSG-LINE2-PART1 are displayed together on the 2-line display, but they must be set independently. If line 2 has been set, and the next message to be displayed only requires line 1, BACKGROUND-STATUS-MSG-LINE2-PART1 must be set to the null string to clear it. This object allows a message to be displayed when it is the highest priority message. Setting this object does not guarantee the message will be displayed; and reading it returns the value last written, not the currently displayed message (use prtConsoleDisplayBufferText to read the display). The priority assigned for displaying this message is one lower than the READY message. In other words, the only message that can be replaced by these objects is the READY message. To clear the message, write a null string to both this object and BACKGROUND-STATUS-MSG-LINE2-PART1.
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.37.2.1The string displayed on the device's front panel in place of the printer's built-in background status string. An example built-in background status string is '00 READY'. Additional information: See BACKGROUND-STATUS-MSG-LINE1-PART1
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.1.2Cancels the print job whose ID matches the value written to the CANCEL-JOB object. The host first learns the job ID using the CURRENT-JOB-PARSING-ID command. If the printer has completely processed the job, the printer responds with <badValue>. If the value of the CURRENT-JOB-PARSING-ID is smaller than the value written to the CANCEL-JOB object, then the printer responds with <badValue>. When read, returns the value of the last job ID what was canceled, or -1 to indicate no job has been canceled. Additional information: If the value written matches the ID of a job that is currently being canceled (for any reason), the printer responds with <noError>. LaserJet 8150 uses job ID's in the range of 0..32767. Because the ID number can wrap to zero, CURRENT-JOB-PARSING-ID may be smaller than the value written to this object; when this occurs, no error will result as long as the ID is for a currently processing job. This object is write only, so the comment in the general description stating the job ID or -1 will be returned on a read does not apply.
.1.3.6.1.4.1.11.2.3.9.4.2.1.6.1An indication of how many print data channels the I/O card supports. Additional information: This object is used by the IIO card to tell the peripheral firmware how many logical channels will be used by the card. This object can only be set once per physical channel. If an attempt is made to set it a subsequent time it is ignored and an return code of <ErrorActionCanNotBePerformedNow.is returned. If new firmware is dynamically downloaded to the Blazers Plus card, and if that firmware uses more logical channels, it is necessary to reset the printer.
.1.3.6.1.4.1.11.2.3.9.4.2.1.6.2Identifies the values of prtAlertIndex, prtAlertSeverityLevel, prtAlertGroup, prtAlertGroupIndex, prtAlertLocation, and prtAlertCode for the latest critical evnet in the prtAlertTable. The binary string is defined as following: <table> ----------------------------------------------------- Field | Filed | Description Offset | Length | ----------------------------------------------------- 0 | 4 | the value of prtAlertIndex 4 | 4 | the value of prtAlertSeverityLevel 8 | 4 | the value of prtAlertGroup 12 | 4 | the value of prtAlertGroupIndex 16 | 4 | the value of prtAlertLocation 20 | 4 | the value of prtAlertCode ------------------------------------------------------ </table> Each field is in Big Endian style. Additional information: This object is used to pass alert information from the peripheral to the IIO card. The standard printer MIB contains the following description: printerAlert TRAP-TYPE ENTERPRISE printerV1Alert VARIABLES { prtAlertIndex, prtAlertSeverityLevel, prtAlertGroup, prtAlertGroupIndex, prtAlertLocation, prtAlertCode } DESCRIPTION 'This trap is sent whenever a critical event is added to the prtAlertTable.' In order to provide this information in the trap packet, the IIO card enables traps on channelPrinterAlert. When a critical alert is generated the peripheral fills the appropriate value into this object and sends it to the card. This object is a structure which contains 24 bytes of data. The structure is: struct structAlertInfo { sint32 prtAlertIndex; sint32 prtAlertSeverityLevel; sint32 prtAlertGroup; sint32 prtAlertGroupIndex; sint32 prtAlertLocation; sint32 prtAlertCode; } thisAlertData;
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.1.1Returns or controls how the device will track clearable warnings. A clearable warning indicates a transient event in the device. The device will continue after the transient event occurs. If CLEARABLE-WARNING is eOff, the device does not track clearable warnings. If CLEARABLE-WARNING is eOn, all clearable warnings will be tracked until cleared (acknowledged). If CLEARABLE-WARNING is eJob, a clearable warning generated due to an event that occurs because of the print job being processed will be automatically cleared when the device has finished processing the job. Example clearable warning events include the device altering resolution or page protection due to memory constraints. The POS will document what transient events are treated as clearable warnings. Additional information: If set to eOn, the warning is displayed until the GO key is pressed or the CONTINUE object is set. If set to eJob, the warning is displayed until the end of the job in which it was generated.
.1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1.19Returns or sets the media size that is used as the DEFAULT-MEDIA-SIZE when a cold reset occurs.
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.42Indicates that the printer can create multiple, collated 'originals' of a job and shows the level of support for this capability. cCollatedOriginals - The printer can create multiple collated originals, or 'mopies'. This is the base functionality required by the other collection items. cProofAndHold - The printer saves a copy of the job while printing the first mopy. Later, this held job can be released and the rest of the mopies will print. cSecurityPrint - The printer spools the job and holds the job until the user releases the job by entering a <<hidden>> at the printer's control panel. cAutoHighlight - The printer prints the job a number of times with a mail distribution list prepended to each job. A different mailing address is highlighted on each mopy. cCollatedAtSpeed - The printer can create multiple collated copies where all copies after the original are printed at engine speed. Additional information: Indicates that the printer can create multiple, collated originals of a job and shows the level of support for this capability. cCollatedOriginals - The printer can create multiple collated originals, or mopies. This is the base functionality required by the other collection items. Without disk, this object will not exist. This will be set at boot-up initialization. If the disk fails, in any way, then the disk error functionality will handle the situation. A color printer (LaserJet 4550) that only has a RAMDISK installed is treated like there is no disk and therefore this object will not exist. The value of this object will be: !cCollatedOriginals - Only FLASH installed cCollatedOriginals - IDE is installed combined with/without FLASH cCollatedOriginals - RAMDISK is On combined with/without FLASH
.1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.10.7This PML object returns the current state of the particular consumable. cAuthLevel1 - Consumable is at Authentication Level 1 cAuthLevel2 - Consumable is at Authentication Level 2 cAuthLevel3 - Consumable is at Authentication Level 3 cGenuineHPUnsupported - Cartridge is GenuineHP intended for another product cDefectiveMemory - Cartridge has a defective memory tag cMissingMemory - Memory tag is missing from the cartridge cLowCondition - Consumable has reached the engine low threshold cOutCondition - Consumable has reached its out threshold cIncorrect - Cartridge inserted is not the correct one cMissing - Consumable is missing from the printer cConfigurableLow - Consumable has reached the configurable low threshold value cStatusArevalid - The status reported on other bits are valid only if the bit is set to 1. If it is 0, the values are invalid. These are the possible states and whenever the consumable is in any of these states, the appropriate bit will be set. The cLowCondition will be set when the consumable reaches the engine low threshold, and cConfigurableLow will be set when the consumable reaches the Configurable Low threshold value. For non-cartridge supplies only cLowCondition, cOutCondition, and cMissing will be supported. Additional information: This object returns the current state of the particular consumable. cAuthLevel1 - Consumable is at Authentication Level 1 cAuthLevel2 - Consumable is at Authentication Level 2 cAuthLevel3 - Consumable is at Authentication Level 3 cGenuineHPUnsupported - Cartridge is GenuineHP intended for another product cDefectiveMemory - Cartridge has a Defective Memory cMissingMemory - Memory is Missing from the Cartridge cLowCondition - Consumable has reached its low threshold cOutCondition - Consumable has reached its out threshold cIncorrect - Cartridge inserted is not the correct one cMissing - Consumable is Missing from the Printer cStatusAreValid - The Status reported on other bits are valid only if this bit is set to 1. If it is 0, the values are invalid. These are the possible states and whenever a Consumable is in any of these states, the appropriate bit will be set. For Non Cartridge Supplies only cLowCondition, cOutCondition and cMissing will be supported.
.1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.10.5.1.3This object is used to report and modify a threshold value indicating the point in the life of a consumable or supply at which a transition to a LOW state will occur.
.1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.10.5.1.2This object reports current usage units in use by the corresponding CONSUMABLE-LIFE-USAGE-UNITS-REMAINING object. Additional information: This object returns the units that CONSUMABLE-LIFE-USAGE-UNITS-REMAINING is returned in. Either ePagesRemaining(1) or eEstimatedPagesRemaining(2).
.1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.10.5.1.1This object reports the current estimate of the number of usage units that remain before this supply is depleted. An installed supply that cannot report such a number will return a value of -2. It is the reponsibility of the host application to query each supply in order to determine an overall device USAGE-UNITS-REMAINING number - the lowest value returned. The unit of measure for this life estimate is determined by reading the corresponding CONSUMABLE-LIFE-USAGE-UNITS object. Additional information: This object will return the Pages or Estimated Pages remaining for the speciffic supply requested by the leaf node of this object.
.1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.10.2This object is used to read and write the URL that can be used to reorder consumables for this device. This URL is set at the factory but can be updated by a reseller or third party. Additional information: The URL can be up to 64 characters long.
.1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.10.1.1.40This object returns the authentication level of the elabel on the given supply. The elabel authentication is returned via the appropriate enum. Additional information: There are three levels of authentication of an ELabel cartridge supported. Each ELabel cartridges level of authentication is provided here, via this enumeration.
.1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.10.1.1.4This object is used to report the usage units used by the CONSUMABLE-STATUS-TOTAL-CAPACITY object. Additional information: This object will only exist on engines that are E-Label capable, but will exist on these engines regardless of the cartridge being Authentic HP or NonHP. This object can be used to ensure the capability of the E-Label feature for a given engine.
.1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.10.1.1.1This object is used to read the cartridge model number associated with this consumable. Additional information: This object will only exist for Authentic HP consumables. If the cartridge is deemed to be NonHP, then this object will not exist.
.1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.10.1.1.26This object is used to report the number of color pages that have been printed by this consumable. Additional information: This object will only exist for Authentic HP consumables. If the cartridge is deemed to be NonHP, then this object will not exist.
.1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.10.1.1.37This object is used to report the number of life units, remaining in the developer. The units of measurement used by this object can be obtained by querying the CONSUMABLE-STATUS-DEVELOPER-LIFE-UNITS object. This object will not exist if this consumable does not contain a developer. Additional information: This object will only exist on engines that are E-Label capable, but will exist on these engines regardless of the cartridge being Authentic HP or NonHP. This object can be used to ensure the capability of the E-Label feature for a given engine.
.1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.10.1.1.36This object is used to report the units used to measure the developer life remaining. Additional information: This object will only exist on engines that are E-Label capable, but will exist on these engines regardless of the cartridge being Authentic HP or NonHP. This object can be used to ensure the capability of the E-Label feature for a given engine.
.1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.10.1.1.39This object is used to report the number of life units, remaining in the drum. The units of measurement used by this object can be obtained by querying the CONSUMABLE- STATUS-DRUM-LIFE-UNITS object. This object will not exist if this consumable does not contain a drum. Additional information: This object will only exist on engines that are E-Label capable, but will exist on these engines regardless of the cartridge being Authentic HP or NonHP. This object can be used to ensure the capability of the E-Label feature for a given engine.
More MIBs from HP
Browse all HPMIBs →Standard SNMP MIB module defining data structures for HPIPFTRAP-MIB.
The BLADETYPE2-NETWORK-MIB module provides SNMP access to Layer 3 configuration parameters, interface statistics, and routing information for blade server network interfaces. It enables monitoring of IP address assignments, interface operational states, and packet counters specific to the blade chassis network subsystem.
Standard SNMP MIB module defining data structures for HP-LASERJET-COMMON-MIB.
Standard SNMP MIB module defining data structures for LJ4100mfp-MIB.
SNMP MIB module
SNMP MIB module