Home/Catalog/LJ9000mfp-MIB

LJ9000mfp-MIB

Detailed view of the defined objects, syntax rules, and hierarchical paths.

1020
Objects
Active
Status
1
Dependencies

Imported Objects

Objects

1,020 total
Object Name
hp
OBJECT IDENTIFIER
.1.3.6.1.4.1.11
dm
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.3.9.4.2
device
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.3.9.4.2.1
system
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1
settings_system
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.1
energy_starrw
INTEGER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.1.1
sleep_moderw
Enumeration
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.1.2
status_system
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2
on_off_linerw
Enumeration
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.5
_pysmi_continuerw
Enumeration
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.6
auto_continuerw
Enumeration
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.7
perm_store_init_occurredro
OCTET STRING
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.10
job_input_auto_continue_timeoutrw
INTEGER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.35
job_input_auto_continue_moderw
OCTET STRING
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.36
background_message
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.37
background_message1
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.37.1
background_status_msg_line1_part1rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.37.1.1
background_message2
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.37.2
background_status_msg_line2_part1rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.37.2.1
background_message3
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.37.3
background_status_msg_line3_part1rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.37.3.1
background_message4
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.37.4
background_status_msg_line4_part1rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.37.4.1
error_log_clearrw
Enumeration
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.38
job_output_auto_continue_timeoutrw
INTEGER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.40
collated_originals_supportro
OCTET STRING
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.42
localization_languages_supportedro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.52
localization_countries_supportedro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.53
host_application_available_memoryro
INTEGER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.59
control_panel_button_pressrw
Enumeration
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.60
control_panel_display_contents_change_counterro
INTEGER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.63
control_panel_display_contents_crcro
INTEGER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.64
control_panel_display
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.65
control_panel_display_graphical_contentsro
OCTET STRING
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.65.1
control_panel_key_pressrw
INTEGER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.66
id
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.3
model_numberro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.1
model_namero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.2
serial_numberro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.3
fw_rom_datecodero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.5
fw_rom_revisionro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.6
device_namerw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.10
device_locationrw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.11
asset_numberrw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.12
interface
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4
simm
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1
simm1
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.1
simm1_typero
Enumeration
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.1.4
simm1_capacityro
INTEGER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.1.5
simm1_bank
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.1.6
simm1_bank1
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.1.6.1
simm1_bank1_typero
Enumeration
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.1.6.1.1
simm1_bank1_capacityro
INTEGER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.1.6.1.2
simm1_bank2
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.1.6.2
simm1_bank2_typero
Enumeration
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.1.6.2.1
simm1_bank2_capacityro
INTEGER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.1.6.2.2
simm2
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.2
simm2_typero
Enumeration
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.2.4
simm2_capacityro
INTEGER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.2.5
simm2_bank
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.2.6
simm2_bank1
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.2.6.1
simm2_bank1_typero
Enumeration
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.2.6.1.1
simm2_bank1_capacityro
INTEGER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.2.6.1.2
simm2_bank2
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.2.6.2
simm2_bank2_typero
Enumeration
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.2.6.2.1
simm2_bank2_capacityro
INTEGER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.2.6.2.2
simm3
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.3
simm3_typero
Enumeration
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.3.4
simm3_capacityro
INTEGER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.3.5
simm3_bank
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.3.6
simm3_bank1
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.3.6.1
simm3_bank1_typero
Enumeration
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.3.6.1.1
simm3_bank1_capacityro
INTEGER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.3.6.1.2
simm3_bank2
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.3.6.2
simm3_bank2_typero
Enumeration
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.3.6.2.1
simm3_bank2_capacityro
INTEGER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.3.6.2.2
simm4
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.4
simm4_typero
Enumeration
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.4.4
simm4_capacityro
INTEGER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.4.5
simm4_bank
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.4.6
simm4_bank1
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.4.6.1
simm4_bank1_typero
Enumeration
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.4.6.1.1
simm4_bank1_capacityro
INTEGER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.4.6.1.2
simm4_bank2
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.4.6.2
simm4_bank2_typero
Enumeration
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.4.6.2.1
simm4_bank2_capacityro
INTEGER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.1.4.6.2.2
mio
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3
mio1
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3.1
mio1_model_namero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3.1.2
mio1_manufacturing_inforo
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3.1.3
mio1_typero
Enumeration
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3.1.4
mio2
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3.2
mio2_model_namero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3.2.2
mio2_manufacturing_inforo
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3.2.3
mio2_typero
Enumeration
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3.2.4
mio3
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3.3
mio3_model_namero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3.3.2
mio3_manufacturing_inforo
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3.3.3
mio3_typero
Enumeration
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.3.3.4
phd
OBJECT IDENTIFIER
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.4.5
Showing 100 of 1,020 OID objects

LJ9000mfp-MIB Technical Reference Overview

The LJ9000mfp-MIB SNMP MIB module published by HP defines 1,020 managed OID objects, including 737 scalar/column metrics, 0 SNMP tables, and 0 trap/notification events.

Key OID Definitions in LJ9000mfp-MIB

_pysmi_continueINTEGERwrite-only
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.6

A device can support a class of errors called continuable errors. When a continuable error is encountered, the device requires a continue event to occur before the device will continue operation. One continue event is setting the CONTINUE object to eInitiateAction. Devices can support other continue events, like auto-continue. A continue event causes the continuable error to be acknowledged, thus allowing the device to continue. Each device needs to list the continuable errors. If the device doesn't currently have an unacknowledged continuable error, the response will contain <genErr>. Additional information: See the CLEARABLE-WARNING and AUTO-CONTINUE objects for the errors that this object will clear.

asset_numberDisplayStringread-write
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.3.12

User defined asset number. The POS should indicate the maximum supported string length. If the user entered string is too long, the device will store as much as possible and will return the <noError>. Additional information: The maximum supported string length is 8 characters. If the user entered string is too long, the device will store the first 8 characters and will return the <noError> status.

auto_continueINTEGERread-write
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.7

Indicates if the device will automatically continue after encountering a continuable error. If AUTO- CONTINUE is set to eOn, the device will automatically generate continue event to acknowledge continuable errors. If AUTO-CONTINUE is set to eOff, then some other continue event will have to acknowledge the continuable error. Additional information: If this is set to eOn the device displays an error message and goes offline for ten seconds. After ten seconds the printer automatically returns to the online state. If this is set to eOff then the device displays an error message and goes offline. It remains offline until the operator presses the GO key or until the CONTINUE object is set. If the printer is not idle, the new value may not take effect until a job boundary is reached. If a get is done on this object before the job boundary is reached, the value last set will be returned.

auto_send_resetINTEGERread-write
.1.3.6.1.4.1.11.2.3.9.4.2.1.2.2.1.78

Enables (1) or disables (0) the auto resend timeout. Additional information: Enables (2) or disables (1) the DEFAULT-RESET-SEND-TIMEOUT.

background_status_msg_line1_part1DisplayStringread-write
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.37.1.1

The string displayed on the device's front panel in place of the printer's built-in background status string. An example built-in background status string is '00 READY'. Additional information: The display size for the OZ printers is 4 X 16. The value of this object and the current value of BACKGROUND-STATUS-MSG-LINE2-PART1 are displayed together on the 4-line display, but they must be set independently. If line 2,3,or 4 has been set, and the next message to be displayed only requires line 1, BACKGROUND-STATUS-MSG-LINE2-PART1, BACKGROUND-STATUS-MSG-LINE3-PART1 and BACKGROUND-STATUS-MSG-LINE4-PART1 must be set to the null string to clear it. This object allows a message to be displayed when it is the highest priority message. Setting this object does not guarantee the message will be displayed; and reading it returns the value last written, not the currently displayed message (use prtConsoleDisplayBufferText to read the display). The priority assigned for displaying this message is one lower than the READY message. In other words, the only message that can be replaced by these objects is the READY message. To clear the message, write a null string to both this object and BACKGROUND-STATUS-MSG-LINE2-PART1.

background_status_msg_line2_part1DisplayStringread-write
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.37.2.1

The string displayed on the device's front panel in place of the printer's built-in background status string. An example built-in background status string is '00 READY'. Additional information: See BACKGROUND-STATUS-MSG-LINE1-PART1

background_status_msg_line3_part1DisplayStringread-write
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.37.3.1

The string displayed on the device's front panel in place of the printer's built-in background status string. An example built-in background status string is 'READY'. Additional information: See BACKGROUND-STATUS-MSG-LINE1-PART1

background_status_msg_line4_part1DisplayStringread-write
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.2.37.4.1

The string displayed on the device's front panel in place of the printer's built-in background status string. An example built-in background status string is 'READY'. Additional information: See BACKGROUND-STATUS-MSG-LINE1-PART1

cancel_jobINTEGERwrite-only
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.1.2

Cancels the print job whose ID matches the value written to the CANCEL-JOB object. The host first learns the job ID using the CURRENT-JOB-PARSING-ID command. If the printer has completely processed the job, the printer responds with <badValue>. If the value of the CURRENT-JOB-PARSING-ID is smaller than the value written to the CANCEL-JOB object, then the printer responds with <badValue>. When read, returns the value of the last job ID what was canceled, or -1 to indicate no job has been canceled. Additional information: If the value written matches the ID of a job that is currently being canceled (for any reason), the printer responds with <noError>. LaserJet 9000mfp uses job ID's in the range of 0..32767. Because the ID number can wrap to zero, CURRENT-JOB-PARSING-ID may be smaller than the value written to this object; when this occurs, no error will result as long as the ID is for a currently processing job. This object is write only, so the comment in the general description stating the job ID or -1 will be returned on a read does not apply.

channel_bytes_receivedINTEGERread-only
.1.3.6.1.4.1.11.2.3.9.4.2.1.7.2.1.3

The low order 31 bits of the number of bytes received by the printer from the host on this logical channel.

channel_bytes_sentINTEGERread-only
.1.3.6.1.4.1.11.2.3.9.4.2.1.7.2.1.2

The low order 31 bits of the number of bytes sent from the printer to the host on this logical channel.

channel_io_errorsINTEGERread-only
.1.3.6.1.4.1.11.2.3.9.4.2.1.7.2.1.4

The low order 31 bits of the number of I/O errors which have occured on this logical channel.

channel_jobs_receivedINTEGERread-only
.1.3.6.1.4.1.11.2.3.9.4.2.1.7.2.1.5

The low order 31 bits of the number of print jobs which have been received on this logical channel.

channel_mioINTEGERread-only
.1.3.6.1.4.1.11.2.3.9.4.2.1.7.2.1.6

The number of the MIO card associated with this logical channel. If this logical channel is not associated with an MIO card a zero is returned. The value returned for each logical channel is the MIO card's physical slot number. The list of supported values should be documented in the device POS. Additional information: The value returned will be zero for channels 1..3. If an MIOA card is installed, channels 4..10 will return a value of one or two. If an MIOB card is installed, channels 11..17 will return a value of one or two but not the same as channels 4..10. When two IIO cards are installed, the value returned by any channel 4..17 may change after the printer is power cycled.

channelifindexINTEGERwrite-only
.1.3.6.1.4.1.11.2.3.9.4.2.1.6.3.1.5

The value of ifIndex which corresponds to this channel. Additional information: After telling the peripheral how many logical channels will be used, the IIO card tells the printer the value of the IfIndex for each channel. The IfIndex is used as part of MIB-II. The values are saved by the peripheral and reported when users request the value of prtChannelIfIndex.

channelinformationOCTETwrite-only
.1.3.6.1.4.1.11.2.3.9.4.2.1.6.3.1.7

Auxiliary information to allow a printing application to use the channel for data submission to the printer. An application capable of using a specific PrtChannelType should be able to use the combined information from the prtChannelInformation and other channel and interface group objects to 'bootstrap' its use of the channel. prtChannelInformation is not intended to provide a general channel description, nor to provide information that is available once the channel is in use. The encoding and interpretation of the prtChannelInformation object is specific to channel type. The description of each PrtChannelType enum value for which prtChannelInformation is defined specifies the appropriate encoding and interpretation, including interaction with other objects. For channel types that do not specify a prtChannelInformation value, its value shall be null (0 length). When a new PrtChannelType enumeration value is registered, its accompanying description must specify the encoding and interpretation of the prtChannelInformation value for the channel type. prtChannelInformation semantics for an existing PrtChannelType may be added or amended in the same manner as described in section 2.4.1 for type 2 enumeration values. The prtChannelInformation specifies values for a collection of channel attributes, represented as text according to the following rules: 1. The prtChannelInformation is coded in the NVT ASCII character set. It is not affected by localization. 2. The prtChannelInformation is a list of entries representing the attribute values. Each entry consists of the following items, in order: a. a keyword, composed of alphabetic characters (A- Z, a-z), that identifies a channel attribute, b. an Equals Sign (=) to delimit the keyword, c. a data value, consisting of NVT ASCII graphics characters (codes 32-126), d. a Line Feed character (code 10) to delimit the data value. No other characters shall be present. Keywords are case-sensitive. Conventionally, keywords are capitalized (including each word of a multi-word keyword), and, since they occupy space in the prtChannelInformation, they are kept short. 3. If a channel attribute has multiple values, it is represented by multiple entries with the same keyword, each specifying one value. Otherwise, there shall be at most one entry for each attribute. 4. By default, entries may appear in any order. If there are ordering constraints for particular entries, these must be specified in their definitions. 5. The prtChannelInformation value may represent information that is not normally coded in textual form, or that is coded in a character set other than NVT ASCII. In these cases, whatever symbolic representation is conventionally used for the information should be used for encoding the prtChannelInformation. (For instance, a binary port value might be represented as a decimal number, Unicode would be represented in UTF-8 format.) 6. For each PrtChannelType for which prtChannelInformation entries are defined, the descriptive text associated with the PrtChannelType enumeration value shall specify the following information for each entry: Title: Brief description phrase, e.g.: 'Port name,'Service Name,' Keyword: The keyword value, eg: 'Port,' 'Service' Syntax: The encoding of the entry value, if it cannot be directly represented by NVT ASCII, Status: 'Mandatory,' 'Optional,' or 'Conditionally Mandatory,' Multiplicity: 'Single' or 'Multiple,' to indicate whether the entry may be present multiple times, Description: Description of the use of the entry, other information required to complete the definition (e.g.: ordering contstraints, interactions between entries). Applications that interpret prtChannelInformation should ignore unrecognized entries, so they are not affected if new entry types are added. Additional information: After telling the peripheral how many logical channels will be used, the IIO card tells the printer the value of the information value of each of the channels. The information is auxiliary information used in conjunction with the channel Type.

channelnumberofchannelsINTEGERwrite-only
.1.3.6.1.4.1.11.2.3.9.4.2.1.6.1

An indication of how many print data channels the I/O card supports. Additional information: This object is used by the IIO card to tell the peripheral firmware how many logical channels will be used by the card. This object can only be set once per physical channel. If an attempt is made to set it a subsequent time it is ignored and an return code of <ErrorActionCanNotBePerformedNow.is returned. If new firmware is dynamically downloaded to the Blazers Plus card, and if that firmware uses more logical channels, it is necessary to reset the printer.

channelprinteralertOCTETread-only
.1.3.6.1.4.1.11.2.3.9.4.2.1.6.2

Identifies the values of prtAlertIndex, prtAlertSeverityLevel, prtAlertGroup, prtAlertGroupIndex, prtAlertLocation, and prtAlertCode for the latest critical evnet in the prtAlertTable. The binary string is defined as following: ------------------------------------------------------ Field | Filed | Description Offset | Length | ------------------------------------------------------ 0 | 4 | the value of prtAlertIndex 4 | 4 | the value of prtAlertSeverityLevel 8 | 4 | the value of prtAlertGroup 12 | 4 | the value of prtAlertGroupIndex 16 | 4 | the value of prtAlertLocation 20 | 4 | the value of prtAlertCode ------------------------------------------------------ Each field is in Big Endian style. Additional information: This object is used to pass alert information from the peripheral to the IIO card. The standard printer MIB contains the following description: printerAlert TRAP-TYPE ENTERPRISE printerV1Alert VARIABLES { prtAlertIndex, prtAlertSeverityLevel, prtAlertGroup, prtAlertGroupIndex, prtAlertLocation, prtAlertCode } DESCRIPTION 'This trap is sent whenever a critical event is added to the prtAlertTable.' In order to provide this information in the trap packet, the IIO card enables traps on channelPrinterAlert. When a critical alert is generated the peripheral fills the appropriate value into this object and sends it to the card. This object is a structure which contains 24 bytes of data. The structure is: struct structAlertInfo { sint32 prtAlertIndex; sint32 prtAlertSeverityLevel; sint32 prtAlertGroup; sint32 prtAlertGroupIndex; sint32 prtAlertLocation; sint32 prtAlertCode; } thisAlertData;

channelprotocolversionOCTETwrite-only
.1.3.6.1.4.1.11.2.3.9.4.2.1.6.3.1.3

The version of the protocol used on this MIO print data channel. Additional information: After telling the peripheral how many logical channels will be used, the IIO card tells the printer the protocol version of each of the channels. The protocol version information is passed using the channelProtocolVersion object. Values are then saved by the peripheral and reported when users request the value of prtChannelProtocolVersion.

channelstateINTEGERwrite-only
.1.3.6.1.4.1.11.2.3.9.4.2.1.6.3.1.4

The state of this print data channel. The value determines whether control information and print data is allowed through this channel or not. Additional information: After telling the peripheral how many logical channels will be used, the IIO card tells the printer the state of each of the channels. The state can change from time to time. The state information is passed using the channelState object. Values are saved by the peripheral and reported when users request the value of prtChannelState.

channelstatusINTEGERwrite-only
.1.3.6.1.4.1.11.2.3.9.4.2.1.6.3.1.6

Sub-unit status is reported in the entries of the principle table in the Group that represents the sub- unit. For sub-units that report a status, there is a status column in the table and the value of this column is always an integer formed in the following way. The SubUnitStatus is an integer that is the sum of 5 distinct values, Availability, Non-Critical, Critical, On-line, and Transitioning. These values are: Availability value Available and Idle 0 000'b Available and Standby 2 010'b Available and Active 4 100'b Available and Busy 6 110'b Unavailable and OnRequest 1 001'b Unavailable because Broken 3 011'b Unknown 5 101'b Non-Critical No Non-Critical Alerts 0 Non-Critical Alerts 8 Critical No Critical Alerts 0 Critical Alerts 16 On-Line Intended state is On-Line 0 Intended state is Off-Line 32 Transitioning At intended state 0 Transitioning to intended state 64 Additional information: After telling the peripheral how many logical channels will be used, the IIO card tells the printer the status of each of the channels. The status can change from time to time. The status information is passed using the channelStatus object. Values are saved by the peripheral and reported when users request the value of prtChannelStatus.

channeltypeINTEGERwrite-only
.1.3.6.1.4.1.11.2.3.9.4.2.1.6.3.1.2

Identifies the type of MIO print data channel. Additional information: After telling the peripheral how many logical channels will be used, the IIO card tells the printer the type of each of the channels. The type information is passed using the channelType object. Values are then saved by the peripheral and reported when users request the value of prtChannelType.

clearable_warningINTEGERread-write
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.6.1.1

Returns or controls how the device will track clearable warnings. A clearable warning indicates a transient event in the device. The device will continue after the transient event occurs. If CLEARABLE-WARNING is eOff, the device does not track clearable warnings. If CLEARABLE-WARNING is eOn, all clearable warnings will be tracked until cleared (acknowledged). If CLEARABLE- WARNING is eJob, a clearable warning generated due to an event that occurs because of the print job being processed will be automatically cleared when the device has finished processing the job. Example clearable warning events include the device altering resolution or page protection due to memory constraints. The POS will document what transient events are treated as clearable warnings. Additional information: If set to eOn, the warning is displayed until the GO key is pressed or the CONTINUE object is set. If set to eJob, the warning is displayed until the end of the job in which it was generated.

cold_reset_media_sizeINTEGERread-write
.1.3.6.1.4.1.11.2.3.9.4.2.1.3.3.1.19

Returns or sets the media size that is used as the DEFAULT-MEDIA-SIZE when a cold reset occurs.

More MIBs from HP

Browse all HPMIBs →