LIVINGSTON-PM4-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for LIVINGSTON-PM4-MIB.
273
Objects
Active
Status
5
Dependencies
Imported Objects
Objects
273 total| Object Name |
|---|
lucentPM4Mib OBJECT IDENTIFIER .1.3.6.1.4.1.307.1.1.2.1 |
RFC1155-SMI Unknown .1.3.6.1.4.1.307.1.1.2.1 |
lucentPM4MibRevThis object specifies the current MIB revision number. Example of the
MIB revision can be PM4xxx for PM4 product and PM3xxx for PM3 products etc.
Where xxx can be any combination of alpha-numeric characters.ro DisplayString .1.3.6.1.4.1.307.1.1.2.1.1 |
lucentPM4SWRevThis object specifies the ComOS revision number. Example of the
ComOS revision can be ComOS4.xx. Where xxx can be any combination
of alpha-numeric characters.ro DisplayString .1.3.6.1.4.1.307.1.1.2.1.2 |
lucentPM4Chassis OBJECT IDENTIFIER .1.3.6.1.4.1.307.1.1.2.1.3 |
lucentPM4ChasSummaryThis object provides general information about the
PortMaster 4 chassis operational status. This object is
read-only. The DisplayString represents a summary of all
the devices in the chassis as follows:
Bytes 1 - 2 '0''0'
Byte 3 'U', 'D', 'M', 'F', 'O'
Byte 4 space
Bytes 5 - 6 '0''1'
Byte 7 'U', 'D', 'M', 'F', 'O'
Byte 8 space
Bytes 9 - 10 '0''2'
Byte 11 'U', 'D', 'M', 'F', 'O'
Byte 12 space
Bytes 13 - 14 '0''3'
Byte 15 'U', 'D', 'M', 'F', 'O'
Byte 16 space
Bytes 17 - 18 '0''4'
Byte 19 'U', 'D', 'M', 'F', 'O'
Byte 20 space
Bytes 21 - 22 '0''5'
Byte 23 'U', 'D', 'M', 'F', 'O'
Byte 24 space
Bytes 25 - 26 '0''6'
Byte 27 'U', 'D', 'M', 'F', 'O'
Byte 28 space
Bytes 29 - 30 '0''7'
Byte 31 'U', 'D', 'M', 'F', 'O'
Byte 32 space
Bytes 33 - 34 '0''8'
Byte 35 'U', 'D', 'M', 'F', 'O'
Byte 36 space
Bytes 37 - 38 '0''9'
Byte 39 'U', 'D', 'M', 'F', 'O'
Byte 40 space
Bytes 41 - 42 '1''0'
Byte 43 'U', 'D', 'M', 'F', 'O'
Byte 44 space
Bytes 45 - 46 '1''1'
Byte 47 'U', 'D', 'M', 'F', 'O'
Byte 48 space
Bytes 49 - 50 '1''2'
Byte 51 'U', 'D', 'M', 'F', 'O'
Byte 52 space
Bytes 53 - 54 '1''3'
Byte 55 'U', 'D', 'M', 'F', 'O'
Byte 56 space
Bytes 57 - 58 '1''4'
Byte 59 'U', 'D', 'M', 'F', 'O'
Byte 60 space
Bytes 61 - 62 '1''5'
Byte 63 'U', 'D', 'M', 'F', 'O'
Byte 64 space
Bytes 65 - 66 'P''1'
Byte 67 'U', 'D', 'M', 'F', 'O'
Byte 68 space
Bytes 69 - 70 'P''2'
Byte 71 'U', 'D', 'M', 'F', 'O'
Byte 72 space
Bytes 73 - 74 'P''3'
Byte 75 'U', 'D', 'M', 'F', 'O'
Byte 76 space
Bytes 77 - 78 'D''1'
Byte 79 'U', 'D', 'M', 'F', 'O'
Byte 80 space
Bytes 81 - 82 'D''2'
Byte 83 'U', 'D', 'M', 'F', 'O'
Byte 84 space
Bytes 85 - 86 'F''1'
Byte 87 'U', 'D', 'M', 'F', 'O'
Byte 88 space
Bytes 89 - 90 'F''2'
Byte 91 'U', 'D', 'M', 'F', 'O'
Byte 92 space
Bytes 93 - 94 'F''3'
Byte 95 'U', 'D', 'M', 'F', 'O'
Byte 96 space
Bytes 97 - 98 'F''4'
Byte 99 'U', 'D', 'M', 'F', 'O'
Legend '#''#' Represents the board number
'F''#' Represents the Fan #
'P''#' Represents the Power Supply #
'D''#' Represents the DC Power Supply #
'U' Up
'D' Down
'M' Maintenance
'F' Failed
'O' Other unknown state.ro DisplayString .1.3.6.1.4.1.307.1.1.2.1.3.1 |
lucentPM4ChasCmdTableTable describing the commands that can be issued to the
agent to perform specific actions to any card, port or
device in the system. For example to erase the flash or
a particular file from the flash. Note that only a station
configured with the appropriate authentication string can
issue commands to the agent. SEQUENCE OF LucentPM4ChasCmdEntry .1.3.6.1.4.1.307.1.1.2.1.3.2 |
lucentPM4ChasCmdEntryEntries in the command table for the chassis commands. This
describes one entry or row in the command table. LucentPM4ChasCmdEntry .1.3.6.1.4.1.307.1.1.2.1.3.2.1 |
lucentPM4ChasCmdIndexThis object specifies the index in the command table.
The values for this object is limited to the size of
the command table on the network element. The size of
the command table is set to 10 which can be changed if
and when users need to schedule more than 10 commands
at a given time.rw INTEGER .1.3.6.1.4.1.307.1.1.2.1.3.2.1.1 |
lucentPM4ChasCmdBoardIdThis object specifies the board for which the command is to
be applied. The values for this object is limited to the Max
number of boards.rw INTEGER .1.3.6.1.4.1.307.1.1.2.1.3.2.1.2 |
lucentPM4ChasCmdUnitTypeThis object specifies the type of the device to which
this command must apply.rw PMUnitType .1.3.6.1.4.1.307.1.1.2.1.3.2.1.3 |
lucentPM4ChasCmdUnitIndexThis object specifies the interface index.rw INTEGER .1.3.6.1.4.1.307.1.1.2.1.3.2.1.4 |
lucentPM4ChasCmdDevIdThis object specifies the sub-unit id for which the command
must be applied to. This value will be used by the agent to
index to the correct sub-device on a board. For example, this
object can have values from 1 - 96 for the modems or 1 - 4 for
T1 or 1 - 3 for the E1.rw INTEGER .1.3.6.1.4.1.307.1.1.2.1.3.2.1.5 |
lucentPM4ChasCmdIdThis object specifies the command. Each command takes a unique
value. The completion status of this command is set in the result
object of the table.rw Enumeration .1.3.6.1.4.1.307.1.1.2.1.3.2.1.6 |
lucentPM4ChasCmdParamsThis object specifies the command parameters. Each parameter must be
seperated by a blank space. The last parameter is terminated with a
';'.rw OCTET STRING .1.3.6.1.4.1.307.1.1.2.1.3.2.1.7 |
lucentPM4ChasCmdResultThis object specifies the command result. The result for each
of the previous 10 commands will be stored in a table, which
can be retrieved by the client when needed.ro PMDiagCmdStatus .1.3.6.1.4.1.307.1.1.2.1.3.2.1.8 |
lucentPM4ConfigMgmt OBJECT IDENTIFIER .1.3.6.1.4.1.307.1.1.2.1.4 |
lucentPM4CmInterfaces OBJECT IDENTIFIER .1.3.6.1.4.1.307.1.1.2.1.4.1 |
lucentPM4CmSerial OBJECT IDENTIFIER .1.3.6.1.4.1.307.1.1.2.1.4.1.1 |
lucentPM4SerialTableA list of serial interface entries. SEQUENCE OF LucentPM4SerialEntry .1.3.6.1.4.1.307.1.1.2.1.4.1.1.1 |
lucentPM4SerialEntryA serial interface entry containing objects at the
physical and session layer. LucentPM4SerialEntry .1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1 |
lucentPM4SerialBoardIndexA unique value for each board in the PortMaster chassis.
The Max value of this variable is limited by the number
of boards in the chassis. This value is limited to 255.ro INTEGER .1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.1 |
lucentPM4SerialUnitTypeUnit type indicates the serial port. The interface table
ifIndex is a combination of board index, unit type and
unit index.ro PMUnitType .1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.2 |
lucentPM4SerialIndexA unique value for each serial interface on a given board.ro INTEGER .1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.3 |
lucentPM4ModemIdThis object is the cross reference to the modem interface table index.
The value is dynamically assigned when the call is established.ro INTEGER .1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.4 |
lucentPM4SerialPortNumberA serial port to which this modem is assigned for this call.ro INTEGER .1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.5 |
lucentPM4SerialPhysTypeThe type of physical serial interface, distinguished
according to the physical/link protocol(s) being
currently used on the interface. When this object is
set to asyn(2), then the service types dial-in, dial-
out, login, and device are valid. When this object is
set to sync(3), the serial service types dial-in, dial-
out and hardwired are valid.ro Enumeration .1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.6 |
lucentPM4SerialPortStatusThe status of the serial interface.ro Enumeration .1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.7 |
lucentPM4SerialDS0StateCross reference value for each DS0 for a given T1/E1 line and a
given board in the PM4 chassis.rw Enumeration .1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.8 |
lucentPM4SerialUserName of the active user. Blank if not active.ro DisplayString .1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.9 |
lucentPM4SerialSessionIdA unique Session Identifier which matches the RADIUS
session ID. Blank when not using RADIUS.ro DisplayString .1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.10 |
lucentPM4SerialTypeHardwiredThe active type of service being provided by the
serial interface.rw Enumeration .1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.11 |
lucentPM4SerialTypeNwDialInThe active type of service being provided by the
serial interface.rw Enumeration .1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.12 |
lucentPM4SerialTypeNwDialoutThe active type of service being provided by the
serial interface.rw Enumeration .1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.13 |
lucentPM4SerialTypeLoginThe active type of service being provided by the
serial interface.rw Enumeration .1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.14 |
lucentPM4SerialTypeDeviceThe active type of service being provided by the
serial interface.rw Enumeration .1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.15 |
lucentPM4SerialTypeDeviceNameDevice name if the lucentPM4SerialTypeDevice is enabled.
This is a string of characters (e.g. /dev/tty1) indicating
the device name.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.16 |
lucentPM4SerialDirectionThe direction the active session was initiated.ro Enumeration .1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.17 |
lucentPM4SerialStartedThe amount of time this session has been active.ro TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.18 |
lucentPM4SerialIdleThe amount of time this session has been idle.ro TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.19 |
lucentPM4SerialInSpeedAn estimate of the serial interface's current inbound
bandwidth in bits per second.ro Gauge .1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.20 |
lucentPM4SerialOutSpeedAn estimate of the serial interface's current outbound
bandwidth in bits per second.ro Gauge .1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.21 |
lucentPM4SerialIpAddressThe IP address associated with the serial interface.
If being used as a network type port, this is the
remote user's IP address. If being used as a device or
login, this is the IP address of the host the user is
connected to.ro IpAddress .1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.22 |
lucentPM4SerialifDescrA textual string containing information about the
network interface bound to the serial interface.ro DisplayString .1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.23 |
lucentPM4SerialInOctetsThe total number of octets received on the
serial interface.ro Counter .1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.24 |
lucentPM4SerialOutOctetsThe total number of octets transmitted on the
serial interface.ro Counter .1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.25 |
lucentPM4SerialQOctetsThe total number of octets queued on the
serial interface.ro Counter .1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.26 |
lucentPM4CmT1E1 OBJECT IDENTIFIER .1.3.6.1.4.1.307.1.1.2.1.4.1.2 |
lucentPM4T1E1TableA list of T1/E1 interface entries. SEQUENCE OF LucentPM4T1E1Entry .1.3.6.1.4.1.307.1.1.2.1.4.1.2.1 |
lucentPM4T1E1EntryA T1/E1 entry containing objects at the physical layer. LucentPM4T1E1Entry .1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1 |
lucentPM4T1E1BoardIndexA unique value for each board in the PM4 chassis.ro INTEGER .1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.1 |
lucentPM4T1E1UnitTypeThis object specifies the type of the unit as the T1/E1
line. This value is a part of the interface table ifIndex.ro PMUnitType .1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.2 |
lucentPM4T1E1IndexA unique value for each T1/E1 interface.ro INTEGER .1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.3 |
lucentPM4T1E1SerialIndexThe value of the instance for the serial port. This object
provides a cross reference from the T1/E1 interface to the
serial port to which it is mapped.ro INTEGER .1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.4 |
lucentPM4T1E1SerialCountThe number of serial ports assigned to this interface. If this is
a Channelized T1/E1, then the count is 24/32. If this is a fractional
T1/E1, then the count can be any number between 1 and a number less
than 24/32.ro INTEGER .1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.5 |
lucentPM4T1E1PhysTypeThe type of interface (T1 or E1).ro Enumeration .1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.6 |
lucentPM4T1E1StatusThe current operational status of the interface.ro PMEquipPRIStatus .1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.7 |
lucentPM4T1E1FunctionThe configured function of the interface.ro Enumeration .1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.8 |
lucentPM4T1E1FramingThe configured line framing.ro Enumeration .1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.9 |
lucentPM4T1E1EncodingThe configured line signal encoding.ro Enumeration .1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.10 |
lucentPM4T1E1PCMThe configured voice modulation.ro Enumeration .1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.11 |
lucentPM4T1E1SuperSignalThe configured supervisory signalling mode for this interface.rw Enumeration .1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.12 |
lucentPM4T1E1StartModeThe configured start mode for this interface.rw Enumeration .1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.13 |
lucentPM4T1E1ChangeTimeThe amount of time since the last status change.ro TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.14 |
lucentPM4T1E1RecvLevelAn estimate of the serial interface's current recieve
signal level in DB.ro Gauge .1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.15 |
lucentPM4T1E1BlueAlarmsThe total number of Blue Alarms on the interface.ro Counter .1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.16 |
lucentPM4T1E1YellowAlarmsThe total number of Yellow Alarms on the interface.ro Counter .1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.17 |
lucentPM4T1E1CarrierLossThe total number of times the interface has lost
carrier.ro Counter .1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.18 |
lucentPM4T1E1SyncLossThe total number of times the interface has lost
frame synchronization.ro Counter .1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.19 |
lucentPM4T1E1BipolarErrorsThe total number of bipolar violations detected
on the interface.ro Counter .1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.20 |
lucentPM4T1E1CRCErrorsThe total number of frame level CRC errors detected
on the interface.ro Counter .1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.21 |
lucentPM4T1E1SyncErrorsThe total number of frame synchronization errors
detected on the interface.ro Counter .1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.22 |
lucentPM4CmModem OBJECT IDENTIFIER .1.3.6.1.4.1.307.1.1.2.1.4.1.3 |
lucentPM4ModemTableA list of modem entries. SEQUENCE OF LucentPM4ModemEntry .1.3.6.1.4.1.307.1.1.2.1.4.1.3.1 |
lucentPM4ModemEntryA modem entry containing objects at the session layer. LucentPM4ModemEntry .1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1 |
lucentPM4ModemBoardIndexA unique value for each modem interface.ro INTEGER .1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.1 |
lucentPM4ModemUnitTypeUnit type specifies the type of device or interface.ro PMUnitType .1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.2 |
lucentPM4ModemIndexA unique value for each modem interface. The value of
this object can be 1 - 96 for a Quad T1, 1 - 94 for a
Tri E1 card.ro INTEGER .1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.3 |
lucentPM4ModemPortNameA textual string containing the name of the serial
interface (ie. S0, S1, etc).ro DisplayString .1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.4 |
lucentPM4ModemStatusA current state of the modem.ro Enumeration .1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.5 |
lucentPM4ModemProtocolThe error correcting protocol being used in the modem.ro Enumeration .1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.6 |
lucentPM4ModemCompressionThe compression being used in the modem interface.ro Enumeration .1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.7 |
lucentPM4ModemInSpeedAn estimate of the modem interface's current inbound
bandwidth in bits per second.ro Gauge .1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.8 |
lucentPM4ModemOutSpeedAn estimate of the modem interface's current outbound
bandwidth in bits per second.ro Gauge .1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.9 |
lucentPM4ModemInByteCountThe total number of bytes received on the
serial interface.ro Counter .1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.10 |
lucentPM4ModemOutByteCountThe total number of bytes transmitted on the
serial interface.ro Counter .1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.11 |
lucentPM4ModemRetrainsThe number of retrains attempted by the modem.ro Counter .1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.12 |
lucentPM4ModemRenegotiatesThe number of renegotiates attempted by the modem.ro Counter .1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.13 |
lucentPM4ModemCallsThe number of times a call received by the modem.ro Counter .1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.14 |
lucentPM4ModemDetectsThe number of analog calls received by the modem.ro Counter .1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.15 |
lucentPM4ModemConnectsThe number of successful calls received by the modem.ro Counter .1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.16 |
lucentPM4CmEther OBJECT IDENTIFIER .1.3.6.1.4.1.307.1.1.2.1.4.1.4 |
lucentPM4EtherTableA list of ethernet interface entries. This object is not
accessible SEQUENCE OF LucentPM4EtherEntry .1.3.6.1.4.1.307.1.1.2.1.4.1.4.1 |
lucentPM4EtherEntryEthernet interface entry containing objects at the
Session/Physical layers. LucentPM4EtherEntry .1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1 |
lucentPM4EtherBoardIndexA unique value for each ethernet board. The manager card
has two ethernet interfaces at present. The ethernet interface
in slot 4 has a board ID 10 and if there is a manager card in
slot 5, the board ID for the interface would be 11.ro INTEGER .1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.1 |
lucentPM4EtherIfTypeThe interface type which together with the board ID and
the interface number will uniquely identify the interface.ro PMUnitType .1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.2 |
lucentPM4EtherIndexA unique value for each ethernet interface. The manager card
has two ethernet interfaces at present. ether0(1) represents
10 Base-T interface and ether1(2) specifies the 10/100 Base-T
auto-sensing ethernet interface.ro Enumeration .1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.3 |
lucentPM4EtherIfIndexIfIndex cross reference value for the ethernet interfaces.
The manager card has two ethernet interfaces at present.
ether0(67436545) represents 10 Base-T interface which corresponds
to board 4 and interface 1. The enumerated value ether1(168099841)
specifies the 10/100 Base-T auto-sensing ethernet interface
which corresponds to board 4 and interface 2. We can add the
standby manager card ethernet interfaces when they are available.ro Enumeration .1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.4 |
lucentPM4EtherPortNameA printable ASCII string specifying the name of the ethernet
port.rw DisplayString .1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.5 |
lucentPM4EtherMacAddressPhysical address of the interface.ro PhysAddress (SNMPv2-TC) .1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.6 |
lucentPM4EtherIpAddressIP address of the interface.rw IpAddress .1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.7 |
lucentPM4EtherIpGatewayIP address of the gateway machine.rw IpAddress .1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.8 |
lucentPM4EtherPriNameServerIP address of the primary name server.rw IpAddress .1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.9 |
lucentPM4EtherAltNameServerIP address of the alternate name server.rw IpAddress .1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.10 |
lucentPM4EtherSubnetMaskSubnet mask of the interface. Used to partition the network
into different branches.rw IpAddress .1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.11 |
lucentPM4EtherInFilterIP Input packet filter. Used to control the type of IP packets
reaching the interface.rw DisplayString .1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.12 |
lucentPM4EtherOutFilterIP output packet filter. Used to control the type of packets
sent out of the interface.rw DisplayString .1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.13 |
lucentPM4EtherOptRipThe RIP protocol enable/disable option.rw Enumeration .1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.14 |
lucentPM4EtherOptSlipThe SLIP protocol enable/disable option.rw Enumeration .1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.15 |
lucentPM4EtherOptEtherDownEthernet interface down enable/disable option.rw Enumeration .1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.16 |
lucentPM4EtherOptBcastHighUse high one(s) broadcast address enable/disable option.rw Enumeration .1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.17 |
lucentPM4EtherOptSnmpDefault SNMP protocol enable/disable option.rw Enumeration .1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.18 |
lucentPM4EtherOptNoListenDo not listen to RIP on the ether interface.rw Enumeration .1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.19 |
lucentPM4EtherOptDefaultRipDefault RIP protocol enable/disable option.rw Enumeration .1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.20 |
lucentPM4EtherOptDefaultListenDefault listen enable/disable option.rw Enumeration .1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.21 |
lucentPM4EtherOptIPFilterIP filter enable/disable option.rw Enumeration .1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.22 |
lucentPM4EtherOptDnsDNS enable/disable option.rw Enumeration .1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.23 |
lucentPM4EtherOptPmeMsgPME Msg. enable/disable option. Whatever that means.rw Enumeration .1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.24 |
lucentPM4EtherOptNoClipNo Clip enable/disable option. Whatever that means.rw Enumeration .1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.25 |
lucentPM4EtherOptEtherIpxEther IPX enable/disable option.rw Enumeration .1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.26 |
lucentPM4EtherOptNetBIOSNet BIOS enable/disable option.rw Enumeration .1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.27 |
lucentPM4EtherOptAccountingAccounting enable/disable option.rw Enumeration .1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.28 |
lucentPM4EtherOptNoPAPPAP enable/disable option.rw Enumeration .1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.29 |
lucentPM4FaultMgmt OBJECT IDENTIFIER .1.3.6.1.4.1.307.1.1.2.1.5 |
lucentPM4FaultMgmtIsolation OBJECT IDENTIFIER .1.3.6.1.4.1.307.1.1.2.1.5.1 |
lucentPM4FaultMgmtChasTrapChassis Trap table which indicates one of several Traps. The
chassis trap table stores the previous history of the traps
which can be retrieved by the management stations at a later
time. This object is not-accessible and present for MIB clarity. SEQUENCE OF LucentPM4FMChasTrapEntry .1.3.6.1.4.1.307.1.1.2.1.5.1.1 |
lucentPM4FMChasTrapEntryEntry in the chassis Trap table. Each trap is uniquely
identified by an index. This object is not accessible and
present for MIB clarity. LucentPM4FMChasTrapEntry .1.3.6.1.4.1.307.1.1.2.1.5.1.1.1 |
lucentPM4FMChasTrapIndexIndex into the Trap table on the agent. This table stores the
previous 500 traps which can be retrieved at any given time.ro INTEGER .1.3.6.1.4.1.307.1.1.2.1.5.1.1.1.1 |
lucentPM4FMChasTrapBoardIDBoard ID is the board number for which this trap is stored. If
the trap is for an auxillary device such as a power supply or
fan, this value is set to zero.ro INTEGER .1.3.6.1.4.1.307.1.1.2.1.5.1.1.1.2 |
lucentPM4FMChasTrapUnitTypeUniquely specifies the unit type for this trap. The unit can be
a board or any other device in the chassis such as a fan or a power
supply.ro PMUnitType .1.3.6.1.4.1.307.1.1.2.1.5.1.1.1.3 |
lucentPM4FMChasTrapUnitIndexUniquely specifies the unit index. The unit index is same as the
ifIndex for T1/E1 interfaces, or the modemIndex for the modems or
fan or power supply index for fan or power supplies.ro INTEGER .1.3.6.1.4.1.307.1.1.2.1.5.1.1.1.4 |
lucentPM4FMChasTrapStatusTrap status specifies the associated object in the Trap is online(2),
offline(3), maintenance(4) or fault(5).ro Enumeration .1.3.6.1.4.1.307.1.1.2.1.5.1.1.1.5 |
lucentPM4FMChasTrapSeverityTrap severity specifies the severity of the Trap for the associated
object.ro PMAlarmType .1.3.6.1.4.1.307.1.1.2.1.5.1.1.1.6 |
lucentPM4FMChasTrapTimeStampThis object stores the timestamp of this trap.ro TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.307.1.1.2.1.5.1.1.1.7 |
lucentPM4FMChasTrapStateThis object stores the Trap state of this trap.rw Enumeration .1.3.6.1.4.1.307.1.1.2.1.5.1.1.1.8 |
lucentPM4FMBoardIndexBoard index uniquely specifies the board in the chassis.
This object is set to zero for power supplies, fans and
other auxillary devices. This object is not accessible
through Get, Get-Next or Set PDUs. It is sent out as part
of the Trap. INTEGER .1.3.6.1.4.1.307.1.1.2.1.5.1.2 |
lucentPM4FMUnitIndexUnit index uniquely specifies the T1/E1 line, or modem or
any device (logical/physical) in the chassis. This object
is not accessible through Get, Get-Next or Set PDUs. It is
sent out as part of the Trap. INTEGER .1.3.6.1.4.1.307.1.1.2.1.5.1.3 |
lucentPM4FMUnitTypeUnit type specifies the T1/E1 line, or modem or any device
in the chassis. This object is not accessible through Get,
Get-Next or Set PDUs. It is sent out as part of the Trap. PMUnitType .1.3.6.1.4.1.307.1.1.2.1.5.1.4 |
lucentPM4FMUnitTrapStatusTrap status specifies the associated object in the Trap.
This object is not accessible other than when produced as
the result of a trap. Enumeration .1.3.6.1.4.1.307.1.1.2.1.5.1.5 |
lucentPM4FMUnitTrapSeverityTrap severity specifies the severity of the Trap for the associated
object. This object is not accessible except when produced as the
result of a trap. PMAlarmType .1.3.6.1.4.1.307.1.1.2.1.5.1.6 |
lucentPM4FMTrapConfig OBJECT IDENTIFIER .1.3.6.1.4.1.307.1.1.2.1.5.2 |
lucentPM4FMEqpTrapCfgEquipment Trap configuration table configure Traps. The
objects in this table are used to enable or disable traps
on a per board/interface/device basis. This object is
not-accessible and present for MIB clarity. SEQUENCE OF LucentPM4FMEqpTrapCfgEntry .1.3.6.1.4.1.307.1.1.2.1.5.2.1 |
lucentPM4FMEqpTrapCfgEntryEntry in the equipment Trap config table. Each trap is
uniquely identified by the board ID, Unit type and unit
index. For auxillary devices such as power supplies and
fans, the board index will be zero, the unit index
identifies the units and the unit type specifies if the
unit is a fan, power supplies etc. This object is not
accessible and present for MIB clarity. LucentPM4FMEqpTrapCfgEntry .1.3.6.1.4.1.307.1.1.2.1.5.2.1.1 |
lucentPM4FMEqpBoardIndexBoard ID for which the Trap configuration need to apply.
The board ID is zero if this trap configuration is for an
auxillary device such as fans or power supplies.ro INTEGER .1.3.6.1.4.1.307.1.1.2.1.5.2.1.1.1 |
lucentPM4FMEqpUnitTypeUnit type alongwith the board index and unit index specifies
uniquely the device/interface which is being configured.ro PMUnitType .1.3.6.1.4.1.307.1.1.2.1.5.2.1.1.2 |
lucentPM4FMEqpUnitIndexUnit index refers to the interface or sub-device such as a
modem, serial port etc. For devices such as power supplies
and fans this object is zero.ro INTEGER .1.3.6.1.4.1.307.1.1.2.1.5.2.1.1.3 |
lucentPM4FMEqpTrapIdTrap ID indicating the trap for which the configuration must
apply.rw Enumeration .1.3.6.1.4.1.307.1.1.2.1.5.2.1.1.4 |
lucentPM4FMEqpTrapCtlTrap control which configures the trap off(1) or on(2).
When the trap is configured as off(1), the trap is not sent
out to the management station. When configures as on(2),
the trap is sent to all the management stations configured
to receive the trap.rw Enumeration .1.3.6.1.4.1.307.1.1.2.1.5.2.1.1.5 |
lucentPM4FMEqpRepTimerIf the trap is to be repeated, this object specifies the time
in seconds. When this object value is set to 0, it indicates
the trap is non-repeat trap.rw INTEGER .1.3.6.1.4.1.307.1.1.2.1.5.2.1.1.6 |
lucentPM4FMT1E1ThreshTrapCfgT1/E1 Threshold Trap configuration table to configure the
thresholds for various T1/E1 traps. This object is
not-accessible and present for MIB clarity. SEQUENCE OF LucentPM4FMThreshT1E1TrapCfgEntry .1.3.6.1.4.1.307.1.1.2.1.5.2.2 |
lucentPM4FMT1E1ThreshTrapCfgEntryEntry in the T1/E1 threshold trap config table. Each
trap is uniquely identified by the board index, unit
type and unit index which is the T1/E1 interface number.
This object is not accessible and present for MIB clarity. LucentPM4FMThreshT1E1TrapCfgEntry .1.3.6.1.4.1.307.1.1.2.1.5.2.2.1 |
lucentPM4FMT1E1ThreshBoardIndexBoard ID for which the Trap threshold configuration must
apply. It includes boards 1 - 10 and other devices such as
power supplies and fans etc.ro INTEGER .1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.1 |
lucentPM4FMT1E1ThreshUnitTypeUnit type for which the Trap threshold configuration
must be applied.ro PMUnitType .1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.2 |
lucentPM4FMT1E1ThreshESsThe threshold for errored seconds on the interface. A trap is
issued when this set limit is exceeded. When this threshold
exceeds, the performance of the interface will degrade. A trap
is generated to notify the adminstrator to take appropriate
action.rw Gauge .1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.3 |
lucentPM4FMT1E1ThreshSESsThe threshold for severely errored seconds on the interface.
A trap is issued when this limit is exceeded. A severely errored
seconds is a second with 320 or more path code violation error
events or one or more out of frame defects or detected AIS defect.rw Gauge .1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.4 |
lucentPM4FMT1E1ThreshSEFSsThe threshold for severely errored framing seconds.
A trap is issued when this threshold is exceeded. A severely
errored framing second is a second with one or more frame
defects or detected AIS defect.rw Gauge .1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.5 |
lucentPM4FMT1E1ThreshUASsThe threshold for unavailable seconds. A trap is issued
when this set threshold is exceeded. Unavailable seconds
are calculated by counting the number of seconds that the
interface is unavailable from the onset of 10 SESs. Once
unavailable, the interface becomes available at the onset
of 10 contiguous no SESs.rw Gauge .1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.6 |
lucentPM4FMT1E1ThreshCSSsThe threshold for controlled slip seconds on the interface.
A trap is issued when this set threshold is exceeded. A
controlled slip second is a one-second interval containing
one or more controlled slips.rw Gauge .1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.7 |
lucentPM4FMT1E1ThreshPCVsThe threshold for path code violations on the interface.
A trap is issued when this set threshold is exceeded. PCV
is a frame syncronization bit error in the D4 and E1-noCRC
format interfaces or a CRC error in the ESF (extended super
frame) and E1-CRC interface formats.rw Gauge .1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.8 |
lucentPM4FMT1E1ThreshLESsThe threshold for line errored seconds on the interface.
A trap is sent to the manager when this set threshold
is exceeded. A line errored second, according to T1M1.3
is a second in which one or more line code violations
were detected.rw Gauge .1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.9 |
lucentPM4FMT1E1ThreshBESsThe threshold for bursty errored seconds on the interface.
A trap is sent to the manager when this set threshold
is exceeded. A bursty errored second is a second with fewer
than 320 and more than 1 path code violations.rw Gauge .1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.10 |
lucentPM4FMT1E1ThreshDMsThe threshold for degraded minutes on the interface.
A trap is sent to the manager when this set threshold
is exceeded. Degraded minutes are determined by collecting
all of the available seconds, after removing any severely
errored seconds. The resulting seconds is grouped into
60 second intervals and if the cumulative errors during
the seconds present in the group exceeds 1E-6.rw Gauge .1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.11 |
lucentPM4FMT1E1ThreshRepTimerIf the trap is to be repeated, this object specifies the time
in seconds. When this object value is set to 0, it indicates
the trap is non-repeat trap.rw INTEGER .1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.12 |
lucentPM4FMT1E1ThreshTrapAckIf set to ack(3), clears the trap condition. If the value is
set to noack(2), leaves the trap condition unchanged.rw Enumeration .1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.13 |
lucentPM4FMEnvTrapCfgEnvironment Trap configuration table. This table
enables configuration of voltage, power levels and
temperature ranges for different units in the chassis.
This object is not-accessible and present for MIB clarity. SEQUENCE OF LucentPM4FMEnvTrapCfgEntry .1.3.6.1.4.1.307.1.1.2.1.5.2.3 |
lucentPM4FMEnvTrapCfgEntryEntry in the environment trap config table. Each trap
is uniquely identified by the board index, unit type
and unit index. This object is not accessible and present
for MIB clarity. LucentPM4FMEnvTrapCfgEntry .1.3.6.1.4.1.307.1.1.2.1.5.2.3.1 |
lucentPM4FMEnvBoardIDBoard ID specifies the board identifier for this trap.
If the trap configuration is for an auxillary device
such as a power supply or fan, this object will be set
to zero. The unit type and the unit index will uniquely
identify the auxillary devices.ro INTEGER .1.3.6.1.4.1.307.1.1.2.1.5.2.3.1.1 |
lucentPM4FMEnvUnitTypeUnit for which the Trap configuration must to apply.ro PMUnitType .1.3.6.1.4.1.307.1.1.2.1.5.2.3.1.2 |
lucentPM4FMEnvUnitIndexUnit index specifies the interface or sub-unit for
this trap (modem or T1/E1 interface etc.). The unit
type and the unit index will uniquely identify the
auxillary devices.ro INTEGER .1.3.6.1.4.1.307.1.1.2.1.5.2.3.1.3 |
lucentPM4FMEnvOptUnitTempThe optimum temperature for this unit. A trap is
generated when the temperature deviates from the
specified range. The temperature is specified as
an integer in degrees farenheit.rw INTEGER .1.3.6.1.4.1.307.1.1.2.1.5.2.3.1.4 |
lucentPM4FMEnvUnitTempRangeThe temperature range above which a trap is generated.
The temperature must be specified as an integer in degree
Farenhiet (for example +/- 5 degree Far.).rw INTEGER .1.3.6.1.4.1.307.1.1.2.1.5.2.3.1.5 |
lucentPM4FMEnvOptUnitPwrLvlThe optimal power level that is appropriate for this unit.
A trap is generated when the power level fluctuates outside
the limits set.rw INTEGER .1.3.6.1.4.1.307.1.1.2.1.5.2.3.1.6 |
lucentPM4FMEnvUnitPwrRangeThe power range specified in volts. A trap is generated
when the power level fluctuates outside the Opt Pwr +/- Range
set.rw INTEGER .1.3.6.1.4.1.307.1.1.2.1.5.2.3.1.7 |
lucentPM4FMEnvTrapCtlThe trap control used to turn the environment traps on or off
for the specified unit(s).rw Enumeration .1.3.6.1.4.1.307.1.1.2.1.5.2.3.1.8 |
lucentPM4PerfMgmt OBJECT IDENTIFIER .1.3.6.1.4.1.307.1.1.2.1.6 |
lucentPM4T1E1PerfMgmt OBJECT IDENTIFIER .1.3.6.1.4.1.307.1.1.2.1.6.1 |
lucentPM4T1E1PMCurPerformance management table representing the performance
statistics of T1/E1 interfaces in the box. This table represents
the current 15 mins statistics. This object is not accessible and
present for clarity purpose. This table is part of RFC 1406. SEQUENCE OF LucentPM4T1E1PMCurEntry .1.3.6.1.4.1.307.1.1.2.1.6.1.1 |
lucentPM4T1E1PMCurEntryPerformance management table entries for all the T1/E1 interfaces
in the box. This table represents the current 15 mins statistics.
This object is not accessible and present for clarity purpose. LucentPM4T1E1PMCurEntry .1.3.6.1.4.1.307.1.1.2.1.6.1.1.1 |
lucentPM4T1E1PMCurBoardBoard number of the interface. The global interface number is
computed by using the Most Significant byte of the ifIndex
and the Least Significant 2 bytes represents the interface index.
Byte 3 will represent the unit type which would be a T1 or E1.ro INTEGER .1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.1 |
lucentPM4T1E1PMCurUnitTypeUnit type indicates the type of interface as T1/E1 or T3/E3
in future. This is part of the interface table ifIndex which
is constructed with boardID, unit type and unit index.ro PMUnitType .1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.2 |
lucentPM4T1E1PMCurLineNumLine number uniquely identifies the T1/E1 interface on a
given board.ro INTEGER .1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.3 |
lucentPM4T1E1PMCurIfIndexInterface table ifIndex cross reference. The global interface
number is computed by using the Most Significant byte as the
board ID and the Least Significant 2 bytes represents the
interface index. The third byte represents the unit type which
will be a T1 or E1. Thus board 0 interface 3 is represented as
0x00050003. The global interface number corresponds to the
IfIndex in MIB II.ro INTEGER .1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.4 |
lucentPM4T1E1PMCurESsThe number of errored seconds, encountered by the line
in the current 15 mins interval.ro Gauge .1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.5 |
lucentPM4T1E1PMCurSESsThe number of Severely Errored Seconds encountered by
the line in the current 15 mins interval.ro Gauge .1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.6 |
lucentPM4T1E1PMCurSEFSsThe number of Severely Errored Framing Seconds
encountered by the line in the current 15 mins interval.ro Gauge .1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.7 |
lucentPM4T1E1PMCurUASsThe number of Unavailable Seconds encountered by the line
in the current 15 mins interval.ro Gauge .1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.8 |
lucentPM4T1E1PMCurCSSsThe number of Controlled Slip Seconds encountered by the line
in the current 15 mins interval.ro Gauge .1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.9 |
lucentPM4T1E1PMCurPCVsThe number of Path Coding Violations encountered by the line
in the current 15 mins interval.ro Gauge .1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.10 |
lucentPM4T1E1PMCurLESsThe number of Line Errored Seconds encountered by the line
in the current 15 mins interval.ro Gauge .1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.11 |
lucentPM4T1E1PMCurBESsThe number of Bursty Errored Seconds encountered by the line
in the current 15 mins interval.ro Gauge .1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.12 |
lucentPM4T1E1PMCurDMsThe number of Degraded Minutes encountered by the line
in the current 15 mins interval.ro Gauge .1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.13 |
lucentPM4T1E1PMCurLCVsThe number of Line Code Violations encountered by the line
in the current 15 mins interval.ro Gauge .1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.14 |
lucentPM4T1E1PMIntPerformance management table representing the performance
statistics of T1/E1 interfaces in the box. This table represents
the 24 hr statistics divided into 96 15 mins intervals. This
object is not accessible and present for clarity purpose.
This table is part of RFC 1406. SEQUENCE OF LucentPM4T1E1PMIntEntry .1.3.6.1.4.1.307.1.1.2.1.6.2 |
lucentPM4T1E1PMIntEntryPerformance management table entries for all the T1/E1 interfaces
in the box. This table represents the 24 hr statistics divided into
96 15 mins intervals. This object is not accessible and present for
clarity purpose. LucentPM4T1E1PMIntEntry .1.3.6.1.4.1.307.1.1.2.1.6.2.1 |
lucentPM4T1E1PMIntBoardBoard number of the interface. The global interface number is
computed by using the Most Significant nibble of the ifIndex
and the Least Significant nibble represents the interface index.
Thus board 0 interface 3 is represented as 0x03 or 03 decimal
and board 10 interface 3 is represented as 0xa3 or 163 decimal.
In an integer, of 4 bytes wide, the 3 MSBytes will all be zeros.
The global interface number corresponds to the IfIndex of MIB II.ro INTEGER .1.3.6.1.4.1.307.1.1.2.1.6.2.1.1 |
lucentPM4T1E1PMIntUnitTypeUnit type indicates the type of physical or logical device. The
unit type for this table is either T1 or E1.ro PMUnitType .1.3.6.1.4.1.307.1.1.2.1.6.2.1.2 |
lucentPM4T1E1PMIntLineNumLine number uniquely identifies the T1/E1 interface for this
board.ro INTEGER .1.3.6.1.4.1.307.1.1.2.1.6.2.1.3 |
lucentPM4T1E1PMIntIntervalInterval number for a given board. The 24 hr period is
divided into 96 15 min intervals, where 1 is the most recent
and 96 is the least recent.ro INTEGER .1.3.6.1.4.1.307.1.1.2.1.6.2.1.4 |
lucentPM4T1E1PMIntIfIndexInterface table ifIndex cross reference. The global interface
number is computed by using the Most Significant byte as the
board ID and the Least Significant 2 bytes represents the
interface index. The third byte represents the unit type which
will be a T1 or E1. Thus board 0 interface 3 is represented as
0x00050003. The global interface number corresponds to the
IfIndex in MIB II.ro INTEGER .1.3.6.1.4.1.307.1.1.2.1.6.2.1.5 |
lucentPM4T1E1PMIntESsThe number of errored seconds, encountered by the line
in the last 24 hrs divided into 96 15 mins intervals.ro Gauge .1.3.6.1.4.1.307.1.1.2.1.6.2.1.6 |
lucentPM4T1E1PMIntSESsThe number of Severely Errored Seconds encountered by
the line for one of the 96 15 mins intervals.ro Gauge .1.3.6.1.4.1.307.1.1.2.1.6.2.1.7 |
lucentPM4T1E1PMIntSEFSsThe number of Severely Errored Framing Seconds
encountered by the line for one of the 96 15 mins
intervals.ro Gauge .1.3.6.1.4.1.307.1.1.2.1.6.2.1.8 |
lucentPM4T1E1PMIntUASsThe number of Unavailable Seconds encountered by the line
for one of the 96 15 mins intervals.ro Gauge .1.3.6.1.4.1.307.1.1.2.1.6.2.1.9 |
lucentPM4T1E1PMIntCSSsThe number of Controlled Slip Seconds encountered by the line
for one of the 96 15 mins intervals.ro Gauge .1.3.6.1.4.1.307.1.1.2.1.6.2.1.10 |
lucentPM4T1E1PMIntPCVsThe number of Path Coding Violations encountered by the line
for one of the 96 15 mins intervals.ro Gauge .1.3.6.1.4.1.307.1.1.2.1.6.2.1.11 |
lucentPM4T1E1PMIntLESsThe number of Line Errored Seconds encountered by the line
for one of the 96 15 mins intervals.ro Gauge .1.3.6.1.4.1.307.1.1.2.1.6.2.1.12 |
lucentPM4T1E1PMIntBESsThe number of Bursty Errored Seconds encountered by the line
for one of the 96 15 mins intervals.ro Gauge .1.3.6.1.4.1.307.1.1.2.1.6.2.1.13 |
lucentPM4T1E1PMIntDMsThe number of Degraded Minutes encountered by the line
for one of the 96 15 mins intervals.ro Gauge .1.3.6.1.4.1.307.1.1.2.1.6.2.1.14 |
lucentPM4T1E1PMIntLCVsThe number of Line Code Violations encountered by the line
for one of the 96 15 mins intervals.ro Gauge .1.3.6.1.4.1.307.1.1.2.1.6.2.1.15 |
lucentPM4T1E1PMTotalPerformance management table representing the performance
statistics of T1/E1 interfaces in the box. This table represents
the 24 hr statistics divided into 96 15 mins intervals. This
object is not accessible and present for clarity purpose.
This table is part of RFC 1406. SEQUENCE OF LucentPM4T1E1PMTotalEntry .1.3.6.1.4.1.307.1.1.2.1.6.3 |
lucentPM4T1E1PMTotalEntryPerformance management table entries for all the T1/E1 interfaces
in the box. This table represents the 24 hr statistics divided into
96 15 mins intervals. This object is not accessible and present for
clarity purpose. LucentPM4T1E1PMIntEntry .1.3.6.1.4.1.307.1.1.2.1.6.3.1 |
lucentPM4T1E1PMTotalBoardBoard number of the interface. The global interface number is
computed by using the Most Significant nibble of the ifIndex
and the Least Significant nibble represents the interface index.
Thus board 0 interface 3 is represented as 0x03 or 03 decimal
and board 10 interface 3 is represented as 0xa3 or 163 decimal.
In an integer, of 4 bytes wide, the 3 MSBytes will all be zeros.
The global interface number corresponds to the IfIndex of MIB II.
This table stores the cumulative values for the past 24 hr period.ro INTEGER .1.3.6.1.4.1.307.1.1.2.1.6.3.1.1 |
lucentPM4T1E1PMTotalUnitTypeUnit type indicates the type of physical or logical device. The
unit type for this table is either T1 or E1.ro PMUnitType .1.3.6.1.4.1.307.1.1.2.1.6.3.1.2 |
lucentPM4T1E1PMTotalLineNumInterface number for a given board. The global interface number is
computed by using the Most Significant nibble of the ifIndex and
the Least Significant nibble represents the interface index. Thus
board 0 interface 3 is represented as 0x03 or 03 decimal and board 10
interface 3 is represented as 0xa3 or 163 decimal. In an integer,
of 4 bytes wide, the 3 MSBytes will all be zeros. The global interface
number corresponds to the IfIndex in MIB II.ro INTEGER .1.3.6.1.4.1.307.1.1.2.1.6.3.1.3 |
lucentPM4T1E1PMTotalIfIndexIfIndex cross reference value. This value is obtained from the
Board/board number and interface number by combining them into
the LSByte. The upper nibble represents the board and the lower
nibble represents the line number.ro INTEGER .1.3.6.1.4.1.307.1.1.2.1.6.3.1.4 |
lucentPM4T1E1PMTotalESsThe cumulative value of errored seconds, encountered by the line
in the last 24 hrs.ro Gauge .1.3.6.1.4.1.307.1.1.2.1.6.3.1.5 |
lucentPM4T1E1PMTotalSESsThe cumulative value Severely Errored Seconds encountered by
the line for the 24 hr period.ro Gauge .1.3.6.1.4.1.307.1.1.2.1.6.3.1.6 |
lucentPM4T1E1PMTotalSEFSsThe cumulative value of Severely Errored Framing Seconds
encountered by the line for the 24 hr period.ro Gauge .1.3.6.1.4.1.307.1.1.2.1.6.3.1.7 |
lucentPM4T1E1PMTotalUASsThe cumulative value of Unavailable Seconds encountered by the line
for the 24 hr period.ro Gauge .1.3.6.1.4.1.307.1.1.2.1.6.3.1.8 |
lucentPM4T1E1PMTotalCSSsThe cumulative value of Controlled Slip Seconds encountered by the line
for the 24 hr period.ro Gauge .1.3.6.1.4.1.307.1.1.2.1.6.3.1.9 |
lucentPM4T1E1PMTotalPCVsThe cumulative value of Path Coding Violations encountered by the line
for the 24 hr period.ro Gauge .1.3.6.1.4.1.307.1.1.2.1.6.3.1.10 |
lucentPM4T1E1PMTotalLESsThe cumulative value of Line Errored Seconds encountered by the line
for the 24 hr period.ro Gauge .1.3.6.1.4.1.307.1.1.2.1.6.3.1.11 |
lucentPM4T1E1PMTotalBESsThe cumulative value of Bursty Errored Seconds encountered by the line
for the 24 hr period.ro Gauge .1.3.6.1.4.1.307.1.1.2.1.6.3.1.12 |
lucentPM4T1E1PMTotalDMsThe cumulative value of Degraded Minutes encountered by the line
for the 24 hr period.ro Gauge .1.3.6.1.4.1.307.1.1.2.1.6.3.1.13 |
lucentPM4T1E1PMTotalLCVsThe cumulative value of Line Code Violations encountered by
the line for the 24 hr period.ro Gauge .1.3.6.1.4.1.307.1.1.2.1.6.3.1.14 |
lucentPM4SecurityMgmt OBJECT IDENTIFIER .1.3.6.1.4.1.307.1.1.2.1.7 |
lucentPM4AcctMgmt OBJECT IDENTIFIER .1.3.6.1.4.1.307.1.1.2.1.8 |
lucentPM4AcctMgmtComm OBJECT IDENTIFIER .1.3.6.1.4.1.307.1.1.2.1.8.1 |
lucentPM4SnmpCommTableThe SNMP Community Table. This table contains entries to restrict
the SNMP get and set operations. SEQUENCE OF LucentPM4SnmpCommEntry .1.3.6.1.4.1.307.1.1.2.1.8.1.1 |
lucentPM4SnmpCommEntryThe entries in the community table. LucentPM4SnmpCommEntry .1.3.6.1.4.1.307.1.1.2.1.8.1.1.1 |
lucentPM4SnmpCommIndexThe index of the command in the command table. A MAX of
10 network management stations must be specified along with
their community names.ro INTEGER .1.3.6.1.4.1.307.1.1.2.1.8.1.1.1.1 |
lucentPM4SnmpCommNameThe name of the SNMP Community for SNMP readers and writers. The size
of the string is limited to 32 characters. All characters in the string
must be printable. DisplayString .1.3.6.1.4.1.307.1.1.2.1.8.1.1.1.2 |
lucentPM4SnmpCommIpAddrThe IP Address of the remote community.rw IpAddress .1.3.6.1.4.1.307.1.1.2.1.8.1.1.1.3 |
lucentPM4SnmpCommReadAccessRead access enable or disable for this community. When
enabled, it allows read-only variable access using this
community string by the SNMP client.rw Enumeration .1.3.6.1.4.1.307.1.1.2.1.8.1.1.1.4 |
lucentPM4SnmpCommWriteAccessWrite access enable or disable for this community. When
enabled, the agent allows write access to the parameters
on the agent by the SNMP clients.rw Enumeration .1.3.6.1.4.1.307.1.1.2.1.8.1.1.1.5 |
lucentPM4SnmpCommTrapsTraps receiving capability enable or disable for
this community. When enabled, the SNMP agent forwards
the traps generated in the box to this SNMP client.rw Enumeration .1.3.6.1.4.1.307.1.1.2.1.8.1.1.1.6 |
lucentPM4SnmpCommStatusThe status of the entry for this community. If the
status is set to normal, it allows requests from this
SNMP client else it discards the requests from this
client.rw Enumeration .1.3.6.1.4.1.307.1.1.2.1.8.1.1.1.7 |
lucentPM4SnmpCommLastErrorIf there is an error on a request, this variable may
contain a message indicating the error.ro DisplayString .1.3.6.1.4.1.307.1.1.2.1.8.1.1.1.8 |
lucentPM4AcctMgmtCallEvent OBJECT IDENTIFIER .1.3.6.1.4.1.307.1.1.2.1.8.2 |
lucentPM4AMCallEventTableCall accounting table containing a list of call events,
which may be used for billing purposes. SEQUENCE OF LucentPM4AMCallEventEntry .1.3.6.1.4.1.307.1.1.2.1.8.2.1 |
lucentPM4AMCallEventEntryThe entries in the accounting/billing table. LucentPM4AMCallEventEntry .1.3.6.1.4.1.307.1.1.2.1.8.2.1.1 |
lucentPM4AMCEIndexCall event index used as an index into the call event table.
The table stores call events which may be used for billing.ro INTEGER .1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.1 |
lucentPM4AMCETimeStampTime stamp for this event in seconds since the last reboot.ro INTEGER .1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.2 |
lucentPM4AMCETypeSpecifies the type of event associated with this entry in the
call event table.ro Enumeration .1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.3 |
lucentPM4AMCESvcTypeThe type of service provided to the user. This field is
meaningful if the event type is servicechanged(4), or
namechanged(5) events. In all other cases, this object
must return none(1).ro Enumeration .1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.4 |
lucentPM4AMCEUNameUser name of the dialed in user. This object returns the
valid user name when the event type is servicechanged(4)
or namechanged(5). In all other cases, it returns a NULL.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.5 |
lucentPM4AMCEModemBoardBoard ID of the modem which handled this call. This value
can be used to diagnose modem related problems (dropping the
call, retraining too frequently etc.).ro INTEGER .1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.6 |
lucentPM4AMCEModemIDIdentifies the specific modem on a board which handled this
call. Can be used to diagnose modem related problems.ro INTEGER .1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.7 |
lucentPM4AMCEModemPortA textual string containing the name of the serial
interface (ie. S0, S1, etc).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.8 |
lucentPM4AMCEDataRateSpecifies the speed of this connection. Speed is specified
as baud rate for modem calls and receive data rate for ISDN
calls. This object returns a 0 for call answered and call
cleared events.ro INTEGER .1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.9 |
lucentPM4AMCECallingPartyIDCalling party ID. This object is valid only for call answered,
call originated, and call cleared events. For all invalid event
types, this object is set to NULL.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.10 |
lucentPM4AMCECalledPartyIDCalled party ID. This object is valid only for call answered,
call originated, and call cleared events. For all invalid event
types, this object is set to NULL.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.11 |
lucentPM4AMCEInOctetsTotal octets received during this call. This object is cleared
at the end of each call.ro INTEGER .1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.12 |
lucentPM4AMCEOutOctetsTotal octets sent out during this call. This object is cleared
at the end of each call.ro INTEGER .1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.13 |
lucentPM4AMCECallChargeCall charge for this call. This object is valid only when the
event is call cleared. For all other events this object is set
to zero.ro INTEGER .1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.14 |
lucentPM4AMCEDisconnReasonReason for the disconnect.ro Enumeration .1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.15 |
lucentPM4Traps OBJECT IDENTIFIER .1.3.6.1.4.1.307.1.1.2.2 |
lucentPM4BoardOfflineTrapBoard down trap. The variable bindings in the Trap packet provide
information about the chassis name, board number and the trap
status. This Trap must be cleared manually. TRAP-TYPE .1.3.6.1.4.1.307.1.1.2.2.0.1 |
lucentPM4BoardOnlineTrapBoard up trap. The variable bindings in the Trap packet provide
information about the chassis name, board number and the trap
status. This Trap must be cleared manually. TRAP-TYPE .1.3.6.1.4.1.307.1.1.2.2.0.2 |
lucentPM4PwrSupFailTrapPower supply failed trap. The variable bindings in the Trap packet provide
information about the chassis name, power supply unit and the trap
status. This Trap must be cleared manually. TRAP-TYPE .1.3.6.1.4.1.307.1.1.2.2.0.3 |
lucentPM4PwrSupWarnTrapPower supply warning trap. The variable bindings in the Trap packet provide
information about the chassis name, power supply unit and the trap
status. This Trap is issued when the power supply fluctuates between a set
threshold. This Trap must be cleared manually. TRAP-TYPE .1.3.6.1.4.1.307.1.1.2.2.0.4 |
lucentPM4PwrSupRestoredTrapPower supply restored trap. The variable bindings in the Trap packet provide
information about the chassis name, power supply unit and the trap
status. This Trap is issued when a failed power supply is restored.
This must be cleared manually. TRAP-TYPE .1.3.6.1.4.1.307.1.1.2.2.0.5 |
lucentPM4FanFailTrapFan failure trap. The variable bindings in the Trap packet provide
information about the chassis name, fan number and the trap
status. This Trap must be cleared manually. TRAP-TYPE .1.3.6.1.4.1.307.1.1.2.2.0.6 |
lucentPM4FanRestoredTrapFan restored trap. The variable bindings in the Trap packet provide
information about the chassis name, fan number and the trap
status. This Trap is issued when the failed fan is restored.
This trap must be cleared manually. TRAP-TYPE .1.3.6.1.4.1.307.1.1.2.2.0.7 |
lucentPM4BoardTempWarnTrapBoard temperature warning trap. The variable bindings in the Trap
packet provide information about the chassis name, unit and the trap
status. This Trap is issued when the board temperature exceeds a set
threshold value. This trap must be cleared manually. TRAP-TYPE .1.3.6.1.4.1.307.1.1.2.2.0.8 |
lucentPM4BoardTempNormalTrapBoard temperature normal trap. The variable bindings in the Trap
packet provide information about the chassis name, unit and the trap
status. This Trap is issued when the board temperature returns to
normal. This trap must be cleared manually. TRAP-TYPE .1.3.6.1.4.1.307.1.1.2.2.0.9 |
lucentPM4BoardTooHotTrapBoard trap. The variable bindings in the Trap packet provide
information about the chassis name, board number and the trap
status. This Trap must be cleared manually. TRAP-TYPE .1.3.6.1.4.1.307.1.1.2.2.0.10 |
lucentPM4ModemFailTrapModem failure trap. The variable bindings in the Trap packet provide
information about the chassis name, modem number and the trap
status. This Trap must be cleared manually. TRAP-TYPE .1.3.6.1.4.1.307.1.1.2.2.0.11 |
lucentPM4T1E1LineDownTrapT1/E1 Line trap. The variable bindings in the Trap packet
provide all the information for the clients to display the
Board ID, Line ID and the status of the line. This Trap could
be generated when the line comes up or goes down once. It must
be cleared manually. TRAP-TYPE .1.3.6.1.4.1.307.1.1.2.2.0.12 |
lucentPM4T1E1LineUpTrapT1/E1 Line trap. The variable bindings in the Trap packet
provide all the information for the clients to display the
Board ID, Line ID and the status of the line. This Trap could
be generated when the line comes up or goes down once. It must
be cleared manually. TRAP-TYPE .1.3.6.1.4.1.307.1.1.2.2.0.13 |
lucentPM4T1E1LineThreshTrapT1/E1 Line trap. The variable bindings in the Trap packet
provide all the information for the clients to display the
Board ID, Line ID and the trap type. This Trap could
be generated when the thresholds for the various performance
statistics (ES, SES etc.) exceed. It must be cleared manually. TRAP-TYPE .1.3.6.1.4.1.307.1.1.2.2.0.14 |
lucentPM4BoardPwrOffTrapThis trap is issued when the power supply to the board is not enough.
The variable bindings in the Trap packet provide information about the
chassis name, board/board number and the trap status. This Trap must be
cleared manually. TRAP-TYPE .1.3.6.1.4.1.307.1.1.2.2.0.15 |
lucentPM4RadiusAuthFailTrapThis trap is issued when the Radius authentication fails.
This Trap must be cleared manually. The trap provides
information about the board and the modem number. TRAP-TYPE .1.3.6.1.4.1.307.1.1.2.2.0.16 |