JUNIPER-ALARM-MIB
Updated Jul 18, 2003AI MIB Summary
The JUNIPER-ALARM-MIB enables SNMP-based monitoring of hardware and software fault conditions on Juniper Networks router chassis, specifically exposing alarm states, severity levels, and event timestamps for system components. This module facilitates the automated detection and correlation of critical infrastructure failures, such as power supply faults, fan failures, and interface errors, within the network management system.
This is Juniper Networks' implementation of enterprise specific MIB for alarms from the router chassis box.
Main OID:
jnxAlarms.1.3.6.1.4.1.2636.3.4
11
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
11 total| Object Name |
|---|
jnxAlarmsThis is Juniper Networks' implementation of enterprise
specific MIB for alarms from the router chassis box. MODULE-IDENTITY .1.3.6.1.4.1.2636.3.4 |
jnxCraftAlarms OBJECT IDENTIFIER .1.3.6.1.4.1.2636.3.4.2 |
jnxAlarmRelayModeThe alarm relay mode of the craft interface
panel for both yellow and red alarms.
Both yellow and red alarms could be cut off
by a front panel Alarm Cutoff / Lamp Test
(ACO/LT) button.
In the pass-on mode, the alarm relay will be
activated to pass on the yellow or red alarms.
In the cut-off mode, both yellow and red alarms
will be cut off from the alarm relays which are
normally connected to audible sirens or visual
flashing devices.ro Enumeration .1.3.6.1.4.1.2636.3.4.2.1 |
jnxYellowAlarms OBJECT IDENTIFIER .1.3.6.1.4.1.2636.3.4.2.2 |
jnxYellowAlarmStateThe yellow alarm state on the craft interface
panel.
The yellow alarm is on when there is some
system warning such as maintenance alert or
significant temperature increase.
This yellow alarm state could be turned off
by the ACO/LT (Alarm Cut Off / Lamp Test) button
on the front panel module.ro Enumeration .1.3.6.1.4.1.2636.3.4.2.2.1 |
jnxYellowAlarmCountThe number of currently active and non-silent
yellow alarms.
This object is independent of the ACO/LT (Alarm
Cut Off / Lamp Test) button.ro Gauge32 .1.3.6.1.4.1.2636.3.4.2.2.2 |
jnxYellowAlarmLastChangeThe value of sysUpTime when the yellow alarm
last changed - either from off to on or vice
versa. Zero if unknown or never changed since
the agent was up.ro TimeStamp (SNMPv2-TC) .1.3.6.1.4.1.2636.3.4.2.2.3 |
jnxRedAlarms OBJECT IDENTIFIER .1.3.6.1.4.1.2636.3.4.2.3 |
jnxRedAlarmStateThe red alarm indication on the craft interface
panel.
The red alarm is on when there is some system
failure or power supply failure or the system
is experiencing a hardware malfunction or some
threshold is being exceeded.
This red alarm state could be turned off by the
ACO/LT (Alarm Cut Off / Lamp Test) button on the
front panel module.ro Enumeration .1.3.6.1.4.1.2636.3.4.2.3.1 |
jnxRedAlarmCountThe number of currently active and non-silent
red alarms.
This object is independent of the ACO/LT (Alarm
Cut Off / Lamp Test) button.ro Gauge32 .1.3.6.1.4.1.2636.3.4.2.3.2 |
jnxRedAlarmLastChangeThe value of sysUpTime when the red alarm
last changed - either from off to on or vice
versa. Zero if unknown or never changed since
the agent was up.ro TimeStamp (SNMPv2-TC) .1.3.6.1.4.1.2636.3.4.2.3.3 |